Development of a kinetic model to describe six types of symbiotic interactions in a formate utilizing microalgae-bacteria cultivation system

This study investigated an algae/formate-utilizing-bacteria system that has been developed for carbon capture. This photomixotrophic consortium consumed formate to support bacterial growth so that the resulting respiration CO 2 could be simultaneously used by algae to avoid CO 2 gas-lipid mass transfer limitation. To understand biomass growth and population interactions in this unique system, a kinetic model has been developed to describe algae and bacteria multiplication, formate and nitrogen utilizations, CO 2 mass transfer, O 2 generation and consumption, lighting condition and shading effect. The simulation indicated that this ecosystem could form six types of interactions (mutualism, commensalism, parasitism, neutralism, amensalism, and competition) depending on the light intensity and nutrient availability. Furthermore, the simulation of both batch culture and chemostat, along with parameter sensitivity tests and experimental observations, offered insights into optimal applications of algae-bacteria consortium based photobiorefinery.

59 BASIC BIOLOGICAL SCIENCES↗

Optimized Illuminance Operation-A Light-Driven Dilution Strategy to Improve Microalgae Biomass Productivity

Periodic dilution is a necessary operation to avoid light limitation due to self-shading as the culture grows dense. However, environmental conditions are constantly changing in outdoor cultivation systems, making it difficult to determine the optimal dilution rate. To address this challenge, this study evaluated a dilution approach based on light penetration to optimize illuminance (OptiLum) in the culture. Biomass concentration was controlled via sensor-feedback directed dilution to ensure that light reaching the bottom of the culture was maintained above the compensation intensity. Under replicated outdoor pond conditions, by keeping the entire culture within a net-positive photosynthetic zone, the OptiLum operation improved the biomass productivities of two top-performing strains, Picochlorum celeri and Tetraselmis striata, by 95 % and 86 %, respectively, compared to conventional semi-continuous batch cultivation. The dilution rate varied daily and was dynamically adjusted based on the light status within the culture, which is concurrently influenced by weather, culture density, and growth rate. The techno-economic analysis showed that the OptiLum operation could reduce biomass production cost by as much as 24 % and 33 % for P. celeri and T. striata, respectively, assuming a low-cost dewatering approach with initial gravity settling of biomass can be realized for both strains. However, a more costly two-stage dewatering strategy, comprising only membranes and centrifuges, may be necessary for non-settling strains, such as P. celeri, which would alternatively increase production costs by 23 % for the OptiLum case. The results demonstrated that the proposed OptiLum operation is a promising approach to improve biomass productivity and lower production cost via weather-responsive and self-adjusting dilution.

09 BIOMASS FUELS↗

Verification and Validation Tests of Gamma Library of MC2-3 for Coupled Neutron and Gamma Heating Calculation

For the accurate assessment of the heat generation rate in fast reactors, the gamma library of MC2 -3 and the MC2 -3 + GAMSOR procedure employing the coupled neutron and gamma heating calculation has been thoroughly verified against Monte Carlo results and validated using the ZPPR-15D gamma dose measurement data. NJOY outputs are post-processed in a consistent way with the NJOY procedure to avoid any missing data or double counting of data. Prompt heating for 379 out of 391 isotopes in the gamma library was verified against MCNP6.2 to within 1% relative error in total heating for most isotopes. For both a simple one-dimensional slab problem representing a sodium cooled fast reactor and the Experimental Breeder Reactor II (EBR-II) benchmark problem, the root-mean-square values of assembly power error were less than 0.5% for fuel assemblies, ~1% in blankets and ~1 to ~3% in reflectors compared to MCNP6.2 results. The most plausible cause for the 3% error in a reflector assembly is believed to be the error in the multigroup neutron cross sections for the reflector assembly. For validation, gamma doses measured with thermoluminiscent dosimeters (TLDs) in the ZPPR-15D experiment were calculated using GAMSOR. Due to the uncertainty in the TLD measurement with regards to the energy deposition of photons and neutrons, the validation data leads to a 12.7% uncertainty on the experimental measurement. With this uncertainty bound, the calculated doses all fell within one standard deviation of the measured value. Combined with the accurate calculation of reaction rate distributions and neutron spectrum measurements, these results indicate good agreement for the neutron and gamma heating calculations that were performed.

coupled neutron and gamma heating↗

Direct current in a stirred optical lattice

We study how the energy dispersion of bosonic atoms loaded into an optical lattice becomes modified due to periodic circular stirring of the lattice to the second order in the strength of stirring. If the lattice breaks mirror symmetry, the bosonic atoms may acquire a nonzero group velocity at the center of the Brillouin zone and produce a nonzero direct current. Furthermore, this effect is similar to the circular photogalvanic effect in solid-state physics. It can be used to transport neutral bosonic atoms in an optical lattice over a given distance in an arbitrary direction. However, when the drive frequency is detuned to avoid resonant transitions with energy absorption, we argue that the induced current is not persistent, but transient. An experimental study of the relaxation of the induced current can provide insight about equilibrization in driven systems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Alkylation of lignin-derived aromatic oxygenates with cyclic alcohols on acidic zeolites

Moderately strong BAS and spacious microporous environments (i.e., large-pore acidic zeolites HBEA and HY) are important criteria for efficient alkylation of phenols with cyclic alcohols and alkenes, while very strong BAS appear to be responsible for catalyst deactivation. BAS confined in HBEA and HY pores show substantially higher turnover frequencies compared to solids without molecularly sized pore constraints. HBEA favors the formation of mono-alkylates, while enhanced formation of di-alkylates is observed on HY. Dehydration of alcohols always dominates over the alkylation at the onset of the reaction. Carbenium ions, the direct electrophile for aromatic oxygenates, are produced mainly from the adsorption and protonation of olefins. The present study shows that for the alkylation of phenols and cyclic alcohols in apolar liquids, the alcohol concentration should be kept low to avoid the formation of unreactive surface dimers and mitigate their inhibitory effects on olefin adsorption and protonation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low temperature catalytic conversion of CH 4 , CO 2 , and C 2 H 4 to value-added C 3 oxygenates and olefins via C 1 -C 2 coupling on Pd-Au/CeO 2

The catalytic conversion of CH 4 and CO 2 in the presence of more reactive co-reactants C 2 H 4 and O 2 on Pd-Au/CeO 2 is achieved at 200 °C and elevated pressures. Propene and acetone were produced from the catalyzed reaction of CH 4 +C 2 H 4 +O 2 ; addition of CO 2 to the reactant stream produced methyl acetate (MAc) but it significantly reduced the C-selectivities of propene and acetone. DRIFTS experiments confirmed the formation of methoxy species from CH 4 +CO 2 at 200 °C, which is an intermediate in the formation of MAc. Here, control experiments with blanks, and with CeO 2 did not show any propene, acetone, or MAc products. The complete oxidation of C 2 H 4 was avoided; the catalyst is stable, and reactant conversions and product yields were sustained for the observed 1200 min time-on-stream, indicating that there is little or no carbon deposition and sintering. This direct coupling of CH 4 and C 2 H 4 intermediates to higher carbon-number products at 200 °C is significant.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of installation faults in air conditioners and heat pumps in single-family homes on U.S. energy usage

To ensure that new residential air conditioners and heat pumps operate optimally, care must be taken during the initial system design and installation to avoid missteps that immediately degrade a system’s performance. Laboratory and simulation studies have quantified the impact that faults can have on capacity and efficiency. Field studies have demonstrated that installation-related faults are commonplace. However, the national impact of installation-related faults cannot be accurately estimated by only simulating a limited number of homes at several fault levels because of the variety of home characteristics and climates involved. In our analysis, we use an improved residential building stock simulation tool to predict the annual energy increase and additional utility costs resulting from two common installation faults: indoor airflow rate and refrigerant charge level. Our method considers the wide range of building characteristics and climate zones of the U.S. housing stock. We use existing field data to develop fault intensity probability distributions to inform our analysis. The study shows that these two faults result in approximately 20.7 TWh/y of additional energy use for central air conditioners and air-source heat pumps in U.S. single-family detached homes, which is a 9% increase over baseline (no-fault) usage, costing homeowners approximately $2.5 billion annually on utility bills. Air-source heat pumps are responsible for a disproportionate fraction of this energy use increase because of the larger number of operating hours compared to central air conditioners and the sensitivity of heating mode performance to the faults analyzed compared to cooling mode.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Short-term apartment-level load forecasting using a modified neural network with selected auto-regressive features

Residential electricity load profiles and their diversity have become increasingly important to realize the benefits of Smart or Transactive Energy Networks (TENs). An important element of TENs will be practical, accurate, and implementable residential load forecasting techniques. While there have been many approaches to short-term load forecasting, few have included forecasting for individual households, partly because the high volatility and idiosyncrasies present in individual household load data can pose significant challenges. In this study, we develop a Convolutional Long Short-Term Memory-based neural network with Selected Autoregressive Features (termed a CLSAF model) to improve short-term household electricity load forecasting accuracy by employing three strategies: autoregressive features selection, exogenous features selection, and a “default” state to avoid overfitting at times of high load volatility. We include aggregations of apartments to floor and building level, because utilities may favor transactive approaches that rely on aggregator models, e.g., a cluster of consumers as opposed to an individual. We demonstrate that the CLSAF model, by virtue of its enhanced feature representation and modest computational resources, can accomplish load forecasting in a multi-family residential building across three spatial granularities (individual apartment/household, floor, and building levels), with an accuracy improvement of up to 25% compared to a persistence model. We propose a data screening technique to characterize time-series electricity-load data. This technique is suitable for integration into a TEN ecosystem and allows one to estimate confidence levels of the load forecasts to optimize computational resources and the risks associated with uncertain forecasts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of size and thermal gradient on supercooling of phase change materials for thermal energy storage

Phase change material based thermal energy storage has many current and potential applications in the heating and cooling of buildings, battery and electronics thermal management, thermal textiles, and dry cooling of power plants. However, connecting lab scale thermal data obtained with differential scanning calorimetry (DSC) to the performance of large-scale practical systems has been a major challenge primarily due to the dependence of supercooling on the size and temperature gradient of the system. Here we show how a phase change material’s supercooling behavior can be characterized experimentally using common lab scale thermal analysis techniques. We then develop a statistics based theoretical model that uses the lab-scale data on small samples to quantitatively predict the supercooling performance for a general thermal energy storage application of any size, including also allowing for the possibility of temperature gradients. Finally, we validate the modeling methodology by comparing to experimental results for solid-solid phase change in neopentyl glycol, which shows how the model successfully predicts the changes in supercooling temperature across a large range of cooling rates (2 orders of magnitude) and volumes (3 orders of magnitude). By accounting for thermal gradients, the model avoids ~2x error incurred by lumped approximations.

36 MATERIALS SCIENCE↗

A forecast-driven decision-making model for long-term operation of a hydro-wind-photovoltaic hybrid system

Hydro-wind-photovoltaic (PV) hybrid system has the potential to increase the integration of renewable energy sources into an existing grid. For the long-term operation of the system, due to the non-storable nature of wind and PV power, it is essentially to decide the optimal long-term carryover storage of cascade reservoirs. However, it remains a challenge due to high uncertainties of long-term forecasts and complicated hydraulic/electrical relationships between cascade reservoirs. Here in this study, a forecast-driven decision-making model is proposed for the hybrid system, which converts the multi-stage long-term operation process into a two-stage operation problem (including current stage and carryover stage) to avoid using longer-horizon forecast information with lower accuracy. First, the carryover stage energy surfaces (CESs) considering the forecast uncertainties of wind, solar and hydro resources are proposed to characterize carryover stage benefit quantitatively. Then a CESs-based forward decision-making optimization model is developed to guide the long-term operation of a hydro-wind-photovoltaic hybrid system. The applications in a hydro-wind-PV hybrid system of Yalong River basin results show that: compared with conventional operation, 1) power generation increases 9.03%; 2) in terms of the carryover storages control, the reservoir impounding and drawdown timing are delayed, and the drawdown depth is increased, which can be used to formulate better reservoir operation rules.

13 HYDRO ENERGY↗

Technoeconomic assessment of hydrogen cogeneration via high temperature steam electrolysis with a light-water reactor

Increased electricity production from renewable energy resources, coupled with low natural gas (NG) prices, has caused existing light-water reactors (LWRs) to experience diminishing returns from the electricity market. This reduction in revenue is forcing LWRs to consider alternative revenue streams, such as introduction hydrogen production or desalination, to remain profitable. This paper performs a technoeconomic assessment (TEA) regarding the viability of retrofitting existing pressurized-water reactors (PWRs) to produce green hydrogen (H 2 ) via high-temperature steam electrolysis (HTSE). Such an integration would allow nuclear facilities to expand into additional markets that may be more profitable in the long term and eliminate CO 2 emissions from the hydrogen production process. Here, to accommodate such an integration, a detailed single market levelized cost of hydrogen (LCOH) and multimarket analyses were conducted of HTSE process operation, requirements, costing, and flexibility. Alongside this costing analysis, market analyses were conducted on the electric and hydrogen markets in the PJM interconnect. Utilizing a novel stochastic, dispatch optimization approach results suggest that a positive gain is achievable, and by operating in multiple markets, the nuclear facility can avoid the sale of electricity during times of low electricity market pricing, while maintaining the ability to capitalize on the high electricity market pricing. It should be noted that the analysis conducted is a differential cash flow analysis and, as such, does not present profit levels. LCOH analysis results demonstrate the potential exists to produce hydrogen at a cost as low as $1.20/kg. This price is lower than traditional steam methane reforming (SMR) allowing nuclear based hydrogen production to disrupt the existing hydrogen production market.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Programmable intrusion detection for distributed energy resources in cyber–physical networked microgrids

We present a programmable intrusion detection method is presented to identify the malicious attacks to distributed energy resources (DERs) in the cyber-physical networked microgrids. The proposed method injects small programmable signals into the system and uses the response to identify abnormal conditions. Because of the low or even zero inertia induced by integrations of DER power-electronic-interfaces, microgrids have very limited resilience capability; and thus, being sensitive to attacks. One microgrid's malfunction caused by attacks can easily propagate to its neighboring systems when several microgrids are connected, leading to catastrophic electricity supply failures. Through the presented method, malicious intrusions can be effectively detected, located, and defended for securing microgrids. Theoretical derivations are provided to define the programmable detection rules. The detection rule is easy and flexible to update, making it difficult for attack actors to gain the knowledge of the detection rules, in order to avoid being detected. Numerical results on a cyber-physical networked microgrids system show that the proposed method is effective and efficient in precisely locating intrusion attacks to the microgrids system.

42 ENGINEERING↗

Analysis of precooling optimization for residential buildings

To reduce peak demand and/or energy cost for residential buildings, optimal precooling strategies are becoming important as an alternative to rule-based precooling strategies that are intuitive but may not be optimal. Since precooling optimization is heavily dependent on a variety of factors such as the home thermal properties, HVAC system, weather, thermal comfort criteria, and utility rate structure, the individual and collective impact of these factors on precooling performance needs to be analyzed. In addition, since the indoor air temperature is affected by heat transfer to and from the interior wall surface, performance analysis in view of the interior wall surface temperature is also essential. Therefore, in this paper, an optimal precooling strategy that accounts for the aforementioned factors and utilizes a second-order thermal network model, is proposed. With this strategy, the HVAC on/off control signal that minimizes 24-hour energy cost while maintaining thermal comfort, is determined. Through extensive simulations, it is found that the proposed optimal precooling strategy is able to adapt to changing conditions and that having a sufficiently low interior wall surface temperature during precooling is critical for avoiding expensive on-peak operation. Here, the reason for the latter is that such a temperature indicates that enough “cooling energy” has been stored. It is also found that weather has the most dominant impact on the precooling performance, followed by home thermal condition, with the rated cooling capacity and utility rate structure having the least impact.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The importance of maldistribution matching for thermal performance of compact heat exchangers

Compact heat exchangers have gained increased attention in recent years, particularly in demanding applications where high temperatures, high pressures, and/or high power densities are required. For decades, the heat exchanger (HX) community believes that flow maldistribution is a key factor for HX effectiveness, that is, reducing the degree of flow maldistribution (MALD) can help increase the HX effectiveness. Therefore, significant efforts have been devoted in the past to optimizing the header geometry to minimize flow maldistribution. This work was initially motivated by this, and the original goal was to figure out a HX header design with the lowest maldistribution. However, by systematically constructing a comprehensive maldistribution matrix, the analysis revealed that the HX effectiveness is not actually determined by the MALD, but instead dominated by the degree of maldistribution mismatch (MISM). This conclusion was also theoretically generalized, which indicated that matching of the local heat capacity rate is key for achieving maximum performance. The MISM provides a local means of tracking this information, while the MALD only provides a global approximation of the maldistribution itself. With this new perspective, flow maldistribution needs not necessarily be avoided, but instead matched between two fluid streams, to improve the HX performance. We demonstrated that by carefully designing the header geometry to match the velocity profiles of the two fluids in a 2 MW PCHE with molten salt and supercritical carbon dioxide (sCO2) as the heat transfer fluids, the HX could achieve a higher effectiveness even when the maldistribution increased. Finally, a technoeconomic study using a CSP system as an example revealed that the use of this new HX design paradigm could result in CSP capital cost savings as large as 16.6%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Decarbonization scenarios of the U.S. Electricity system and their costs

Decarbonizing the electricity system to zero-carbon emission is crucial for climate change mitigation. Previous studies have shown that such a transition in the United States (U.S.) may lead to higher system cost compared to a business-as-usual case, but it is not well-known how the cost of electricity generation varies at sub-regional level under the transition, and studies have rarely evaluated the trade-off between the cost and avoided climate damages, as well as the potential roles of negative emission technologies (NETs) in the electricity decarbonization. In this work, we present a regionally resolved national model to quantify the cost of decarbonizing the U.S. electricity system under a set of possible scenarios. The results show that, compared to the reference scenario without a decarbonization policy, reaching zero CO 2 emission by 2050 would incur, depending on the scenarios, 335-494 billion USD additional cost to the U.S. electric power sector during 2020-2050. The regional costs of electricity generation ranges from 2.4 to 4.7 cent/kWh, largely due to the generation profiles and renewable resources availability of those regions. The additional costs can be translated to an average CO 2 abatement cost of 29-59 USD/metric ton CO 2 (with 2%-7% discount rates), which are comparable to the social cost of carbon in the literature at around 4% discount rate. The results also show that the cost of mitigating the last few percent CO 2 emission from the U.S. electricity system may exceed the costs of NETs, indicating an opportunity for NETs to contribute to electricity decarbonization.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal management of electric hotel loads in mild hybrid heavy duty truck

Here, the problem of engine idling for heavy-duty trucks has been under study for decades with Auxiliary Power Units (APUs) and Truck Stop Electrification (TSE) as the most compelling solutions. With the electrification of trucks approaching feasibility in terms of cost-effective technology, hybridization offers another “degree of freedom” to tackle the problem. Here, this work aims at exploiting a battery pack of a 48 V mild-hybrid heavy-duty truck to store sufficient onboard energy for powering the auxiliary loads during the hoteling. This problem is not trivial, as the battery packs typically cannot recover the entire energy required through regeneration alone; hence an optimal energy management strategy needs to be employed to charge the battery through the engine during drive operation. This strategy optimizes powertrain performances among the four modes: (i) Engine of Coasting (EOC), (ii) Regeneration by braking, (iii) Regeneration by engine, and (iv) engine idling. This paper presents the development of a Dynamic Programming (DP) framework that employs a multi-objective cost function to minimize the fuel consumption and maximize the regeneration using the above-mentioned four modes. A typical heavy-duty truck drive cycle is used to represent the drive phase, with mandatory hoteling stops as per regulations. A comprehensive powertrain model is developed using validated components’ model. The DP employs two state variables: battery State-of-Charge (SOC) and engine mode, and three control inputs: (i) the engine ON–OFF state, (ii) clutch engagement state, and (iii) power request at the Electric Machine (EM) for calculating optimal SOC trajectory. The framework also tackles rapid engine ON–OFF scenarios to avoid the challenges associated with DP and the compromises in fuel cost with those approaches. Finally, the effectiveness of the proposed framework is tested for potential fuel savings on two different battery packs by performing the full cycle simulations. The results show 6.47% of fuel consumption reduction as compared to traditional APU-based heavy-duty truck.

33 ADVANCED PROPULSION SYSTEMS↗

A bi-level data-driven framework for fault-detection and diagnosis of HVAC systems

Long-term operation of heating, ventilation, and air conditioning (HVAC) systems will eventually lead to a range of HVAC system failures, resulting in excessive energy consumption and maintenance costs. Here, to avoid HVAC malfunctioning, fault detection diagnostic (FDD) is utilized as a common practice. Machine learning methods have lately received considerable interest for FDD analysis of HVAC systems due to their high detection accuracy. Meanwhile, HVAC malfunctions are regarded as rare occurrences, hence normal operating data samples are much more accessible than data samples in faulty and malfunctioning conditions. The dominating frequency of normal operation in HVAC datasets has also led to heavily biased classification algorithms within the literature. Moreover, the focus of previous literature has been on increasing the accuracy of the models which leads to a high number of false positives (misleading alarms) in the system. In order to enhance the performance of diagnostic procedures and fill the mentioned gaps, this study proposes a novel data-driven framework. A bi-level machine learning framework is developed for diagnosing faults in air handling units (AHUs) and rooftop units (RTUs) based on principal component analysis (PCA), time series anomaly detection, and random forest (RF). It is shown that PCA can reduce the dataset dimension with one principal component accounting for 95% of data variance. Also, the random forest could classify the faults with 89% precision for single-zone AHU, 85% precision for RTU, and 79% for multi-zone AHU. By proposing this framework, three persistent challenges are addressed: (I) minimizing false positives; (II) accounting for data imbalance; and (III) normal condition monitoring of equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The interaction of wholesale electricity market structures under futures with decarbonization policy goals: A complexity conundrum

Competitive wholesale electricity markets can help facilitate energy system decarbonization by incentivizing investments in clean energy technologies that meet evolving system needs. We explore market structure impacts on generator operations and deployment by risk-averse, heterogeneous investor firms using the Electricity Markets and Investment Suite - Agent-based Simulation (EMIS-AS) model. Here we apply clean energy targets of 45%-100% by 2035 considering energy, ancillary services, capacity, and clean energy credit products and pricing and eligibility rules. Results highlight a complexity conundrum, whereby finding the "right" market design to achieve decarbonization goals and avoid unintended consequences can be a highly-nuanced, non-incremental challenge. Carefully designed energy-only markets can achieve the same clean energy targets as capacity market structures but with different revenue and profitability outcomes. Operating reserve demand curve-based scarcity pricing can substitute capacity markets for similar deployment outcomes. Carbon pricing alone is most effective at achieving decarbonization levels at low clean energy targets, and clean energy credit markets and carbon pricing are substitutionary at high clean energy targets. Restricting technology participation in capacity and operating reserve markets can impact deployment and operations, even for nonrestricted technologies. Adding an inertia product with fast frequency response yields insufficient provision at high clean energy targets, but work is needed to understand frequency requirements and capabilities.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗