Search NASA⌕ Search

SEARCH · Search NASA

Results for “biasing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Interfacial Characterization of Positive Bias Voltage Degradation in PV Modules

Degradation from high system voltage is a prevailing failure mode in fielded photovoltaic modules, and the degradation mechanism is inherently dependent on the bias polarity. Here we report the effects of positive bias. Modules under positive bias demonstrated a significant photocurrent loss caused by two routes. First, delamination and discoloration of the silicon nitride layer, leading to optical loss determined by reflectance measurements. Second, chemical discoloration of the cell gridlines and encapsulant (EVA), which is linked to an electrochemical reaction at the silver electrodes. Chemical compositional analysis using X-ray photoemission spectroscopy demonstrated that the discoloration is attributed to Ag 2 S and/or Ag 2 O. Evidence of Ag ion migration from the cell grid into the encapsulant is observed after shallow depth profiling on the EVA surface. However, Ag was not detected at the EVA/glass interface, inferring limited Ag ion transport through the EVA. The source of sulfur is believed to be ambient air, which diffused into the module through the breathable backsheet.

characterization↗

Aggregation bias and its drivers in large‐scale flood loss estimation: A Massachusetts case study

Abstract Large‐scale estimations of flood losses are often based on spatially aggregated inputs. This makes risk assessments vulnerable to aggregation bias, a well‐studied, sometimes substantial outcome in analyses that model fine‐grained spatial phenomena at coarse spatial units. To evaluate this potential in the context of large‐scale flood risk assessments, we use data from a high‐resolution flood hazard model and structure inventory for over 1.3 million properties in Massachusetts and examine how prominent data aggregation approaches affect the magnitude and spatial distribution of flood loss estimates. All considered aggregation approaches rely on aggregate structure inventories but differ in whether flood hazard is also aggregated. We find that aggregating only structure inventories slightly underestimates overall losses (−10% bias), and when flood hazard data is spatially aggregated to even relatively small spatial units (census block), statewide aggregation bias can reach +366%. All aggregation‐based procedures fail to capture the spatial covariation of inputs distributions in the upper tails that disproportionately generate total expected losses. Our findings are robust to several key assumptions, add important context to published risk assessments and highlight opportunities to improve flood loss estimation uncertainty quantification.

54 ENVIRONMENTAL SCIENCES↗

Using ARM Measurements to Understand and Reduce the Double ITCZ Biases in the Community Atmospheric Model

1. Understanding of the observed variability of ITCZ in the equatorial eastern Pacific. The annual mean precipitation in the eastern Pacific has a maximum zonal band north of the equator in the ITCZ where the maximum SST is located. During the boreal spring (referring to February, March, and April throughout the present paper), because of the accumulated solar radiation heating and oceanic heat transport, a secondary maximum of SST exists in the southeastern equatorial Pacific. Associated with this warm SST is also a seasonal transitional maximum of precipitation in the same region in boreal spring, exhibited as a weak double ITCZ pattern in the equatorial eastern Pacific. This climatological seasonal variation, however, varies greatly from year to year: double ITCZ in the boreal spring occurs in some years but not in other years; when there a single ITCZ, it can appear either north, south or at the equator. Understanding this observed variability is critical to find the ultimate cause of the double ITCZ in climate models. Seasonal variation of ITCZ south of the eastern equatorial Pacific: By analyzing data from satellites, field measurements and atmospheric reanalysis, we have found that in the region where spurious ITCZ in models occurs, there is a “seasonal cloud transition” — from stratocumulus to shallow cumulus and eventually to deep convection —in the South Equatorial Pacific (SEP) from September to April that is similar to the spatial cloud transition from the California coast to the equator. This seasonal transition is associated with increasing sea surface temperature (SST), decreasing lower tropospheric stability and large-scale subsidence. This finding of seasonal cloud transition points to the same source of model errors in the ITCZ simulations as in simulation of stratocumulus-cumulus-deep convection transition. It provides a test for climate models to simulate the relationships between clouds and large-scale atmospheric fields in a region that features a spurious double Inter-tropical Convergence Zone (ITCZ) in most models. This work is recently published in Yu et al. (2016). Interannual variation of ITCZ south of the eastern equatorial Pacific: By analyzing data from satellites, field measurements and atmospheric reanalysis, we have characterized the interannual variation of boreal spring precipitation in the eastern tropical Pacific and found the cause of the observed interannual variability. We have shown that ITCZ in this region can occur as a single ITCZ along the Equator, single ITCZ north of the Equator, single ITCZ south of the Equator, and double ITCZ on both sides of the Equator. We have found that convective instability only plays a secondary role in the ITCZ interannual variability. Instead, the remote impact of the Pacific basin-wide SST on the horizontal gradient of surface pressure and wind convergence is the primary driver of this interannual variability. Results point to the need to include moisture convergence in convection schemes to improve the simulation of precipitation in the eastern tropical Pacific. This result has been recently submitted for publication (Yu and Zhang 2016). 2. Improvement of model parameterizations to reduce the double ITCZ bias We analyzed the current status of climate model performance in simulating precipitation in the equatorial Pacific. We have found that the double ITCZ bias has not been reduced in CMIP5 models relative to CMIP4 models. We have characterized the dynamic structure of the common bias by using precipitation, sea surface temperature, surface winds and sea-level. Results are published in Zhang et al. (2015): Since cumulus convection plays a significant role in the double ITCZ behavior in models, we have used measurements from ARM and other sources to carry out a systematic analysis of the roles of shallow and deep convection in the CAM. We found that in both CAM4 and CAM5, when the intensity of deep convection decreases as a result of parameterization change, the intensity of shallow convection increases, leading to very different changes in precipitation partitions but little change in the total precipitation. The different precipitation partition however can manifest themselves in other measures of model performances including temperature and humidity. This study points to the need to treat model physical parameterizations as integrated system rather than individual components. Results from this study are published in Wang and Zhang (2013). Since shallow convection interacts with the deep convection scheme and surface turbulence to trigger the double ITCZ, we studied methods to improve the shallow convection scheme in climate models. We investigated the bulk budgets of the vertical velocity and its parameterization in convective cores, convective updrafts, and clouds by using large-eddy simulation (LES) of four shallow convection cases including one from ARM. We proposed optimal forms of the Simpson and Wiggert equation to calculate the vertical velocity in bulk mass flux convection schemes for convective cores, convective updrafts, and convective clouds as parameterization schemes. The new scheme is published in Wang and Zhang (2014). By using long-term radar-based ground measurements from ARM, we derived a scale-aware inhomogeneity parameterization of cloud liquid water in climate models. We found a relationship between the inhomogeneity parameter and the model grid size as well as atmospheric stability. This relationship is implemented in the CESM to describe the subgrid-scale cloud inhomogeneity. Relative to the default CESM with the finite-volume dynamic core at 2-degree resolution, the new parameterization leads to smaller cloud inhomogeneity and larger cloud liquid-water path in high latitudes, and the opposite effect in low latitudes, with the regional impact on shortwave cloud radiation effect of up to 10 W/m 2 . This is due to both the smaller (larger) grid size in high (low) latitudes in the longitude-latitude grid setting of CESM and the more stable (unstable) atmosphere. This parameterization is expected lead to more realistic simulation of tropical precipitation in high-resolution models. Results from this study are reported in Xie and Zhang (2015).

54 ENVIRONMENTAL SCIENCES↗

The Combination of Rejection Sampling with Biased Probability Density Sampling (with Special Comments on MCNP "Cookie Cutter" Rejection)

Sampling from biased probability densities and rejection sampling are both very common Monte Carlo techniques. As far as I know, the combination of sampling from a biased density and rejection sampling has not been developed. This note develops the theory for sampling from a biased density and then accepting or rejecting that sampling.

97 MATHEMATICS AND COMPUTING↗

Biases in preconstruction estimates of wind plant annual energy production

Estimating the energy yield of a wind plant during the preconstruction phase is a historically difficult task, even with industry improvements in these estimations. We build on prior research comparing the realized energy production of wind plants and their estimated annual energy production P50 values (median energy production), using owner-provided energy production and losses. We produced similar results to prior studies but with a slightly increasing bias of overestimating median energy production (a bias between realized and estimated energy production of −7.4 % to −6.6 %, depending on the scenario, as opposed to −6.7 % to −5.5 % from earlier studies). In addition to assessing annual energy production P50 bias, we compared both the 1-year and the long-term annual energy production P90 and uncertainty energy yield assessment estimates to the observed long-term-corrected energy production. We found that neither the energy yield assessment uncertainty nor the P90 is conservative enough compared to the observed distribution of prediction errors, suggesting significant room for improvement in the energy yield assessment process.

17 WIND ENERGY↗

An Overview of Wind Energy Production Prediction Bias, Losses, and Uncertainties

The financing of a wind farm directly relates to the preconstruction energy yield assessments which estimate the annual energy production for the farm. The accuracy and the precision of the preconstruction energy estimates can dictate the profitability of the wind project. Historically, the wind industry tended to overpredict the annual energy production of wind farms. Experts have been dedicated to eliminating such prediction errors in the past decade, and recently the industry is recording near-zero average energy prediction bias. Herein, we present an overview of the energy yield assessment errors across the global wind energy industry. We identify a long-term trend of reduction in the overprediction bias, whereas the uncertainty associated with the prediction error is prominent. We also summarize the recent advancements of the wind resource assessment process that justify the bias reduction, including the improvements in modeling and measurement techniques. Additionally, because the energy losses and uncertainties substantially influence the prediction error, we document and examine the estimated and observed loss and uncertainty values from the literature, according to the proposed framework in the International Electrotechnical Commission 61400-15 wind resource assessment standard. From our findings, we highlight the opportunities for the industry to move forward, such as the validation and reduction of prediction uncertainty, and the prevention of energy losses caused by wake effect and environmental events. Overall, this study provides a summary on how the wind energy industry has been quantifying and reducing prediction errors, energy losses, and production uncertainties. Finally, for this work to be as reproducible as possible, we include all of the data used in the analysis in appendices to the manuscript.

literature review↗

Bias Reduction and Filter Convergence for Long Range Stereo

We are concerned here with improving long range stereo by filtering image sequences. Traditionally, measurement errors from stereo camera systems have been approximated as 3-D Gaussians, where the mean is derived by triangulation and the covariance by linearized error propagation. However, there are two problems that arise when filtering such 3-D measurements. First, stereo triangulation suffers from a range dependent statistical bias; when filtering this leads to over-estimating the true range. Second, filtering 3-D measurements derived via linearized error propagation leads to apparent filter divergence; the estimator is biased to under-estimate range. To address the first issue, we examine the statistical behavior of stereo triangulation and show how to remove the bias by series expansion. The solution to the second problem is to filter with image coordinates as measurements instead of triangulated 3-D coordinates.

robotics↗

Instrumental Biases in Ionospheric Measurement Derived from GPS Data

Line-of-sight ionosphere measurements derived from differencing dual frequency GPS range data are corrupted by instrumental biases in both receiver and GPS satellite transmitters due to hardware delays in the L1 and L2 signal paths. Using a global ionospheric shell model to fit GPS based ionospheric delay data from a world wide network of 30 to 40 receivers, we can estimate, with a single fit, satellite biases for the entire GPS constellation and receiver biases for all the uncalibrated receivers.

GPS↗

A Segmentation Algorithm for Characterizing Rise and Fall Segments in Seasonal Cycles: an Application to Xco2 to Estimate Benchmarks and Assess Model Bias

There is more useful information in the time series of satellite-derived column-averaged carbon dioxide (XCO2) than is typically characterized. Often, the entire time series is treated at once without considering detailed features at shorter timescales, such as nonstationary changes in signal characteristics – amplitude, period and phase. In many instances, signals are visually and analytically differentiable from other portions in a time series. Each rise (increasing) and fall (decreasing) segment in the seasonal cycle is visually discernable in a graph of the time series. The rise and fall segments largely result from seasonal differences in terrestrial ecosystem production, which means that the segment's signal characteristics can be used to establish observational benchmarks because the signal characteristics are driven by similar underlying processes. We developed an analytical segmentation algorithm to characterize the rise and fall segments in XCO2 seasonal cycles. We present the algorithm for general application of the segmentation analysis and emphasize here that the segmentation analysis is more generally applicable to cyclic time series. We demonstrate the utility of the algorithm with specific results related to the comparison between satellite- and model-derived XCO2 seasonal cycles (2009–2012) for large bioregions across the globe. We found a seasonal amplitude gradient of 0.74–0.77 ppm for every 10∘ of latitude in the satellite data, with similar gradients for rise and fall segments. This translates to a south–north seasonal amplitude gradient of 8 ppm for XCO2, about half the gradient in seasonal amplitude based on surface site in situ CO2 data (∼19 ppm). The latitudinal gradients in the period of the satellite-derived seasonal cycles were of opposing sign and magnitude (−9 d per 10∘ latitude for fall segments and 10 d per 10∘ latitude for rise segments) and suggest that a specific latitude (∼2∘ N) exists that defines an inversion point for the period asymmetry. Before (after) the point of asymmetry inversion, the periods of rise segments are lesser (greater) than the periods of fall segments; only a single model could reproduce this emergent pattern. The asymmetry in amplitude and the period between rise and fall segments introduces a novel pattern in seasonal cycle analyses, but, while we show these emergent patterns exist in the data, we are still breaking ground in applying the information for science applications. Maybe the most useful application is that the segmentation analysis allowed us to decompose the model biases into their correlated parts of biases in amplitude, period and phase independently for rise and fall segments. We offer an extended discussion on how such information about model biases and the emergent patterns in satellite-derived seasonal cycles can be used to guide future inquiry and model development.

segmentation algorithm↗

Measurements of the asymmetric, dynamic sheath around a pulse biased sphere immersed in flowing metal plasma

A long-probe technique was utilized to record the expansion and retreat of the dynamic sheath around a spherical substrate immersed in pulsed cathode arc metal plasma. Positively biased, long cylindrical probes were placed on the side and downstream of a negatively pulsed biased stainless steel sphere of 1" (25.4 mm) diameter. The amplitude and width of the negative high voltage pulses (HVP) were 2 kV, 5 kV, 10 kV, and 2 mu s, 4 mu s, 10 mu s, respectively. The variation of the probe (electron) current during the HVP is a direct measure for the sheath expansion and retreat. Maximum sheath sizes were determined for the different parameters of the HVP. The expected rarefaction zone behind the biased sphere (wake) due to the fast plasma flow was clearly established and quantified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Influence of Superparameterization and a Higher-Order Turbulence Closure on Rainfall Bias Over Amazonia in Community Atmosphere Model Version 5

In this work, we evaluate the Community Atmosphere Model Version 5 (CAM5) with a higher-order turbulence closure scheme, named Cloud Layers Unified By Binomials (CLUBB), and a Multiscale Modeling Framework (MMF) with two different microphysics configurations to investigate their influences on rainfall simulations over Southern Amazonia. The two different microphysics configurations in MMF are the one-moment cloud microphysics without aerosol treatment (SAM1MOM) and two-moment cloud microphysics coupled with aerosol treatment (SAM2MOM). Results show that both MMF-SAM2MOM and CLUBB effectively reduce the low biases of rainfall, mainly during the wet season. The CLUBB reduces low biases of humidity in the lower troposphere with further reduced shallow clouds. The latter enables more surface solar flux, leading to stronger convection and more rainfall. MMF, especially MMF-SAM2MOM, unstablizes the atmosphere with more moisture and higher atmospheric temperatures in the atmospheric boundary layer, allowing the growth of more extreme convection and further generating more deep convection. MMF-SAM2MOM significantly increases rainfall in the afternoon, but it does not reduce the early bias of the diurnal rainfall peak; LUBB, on the other hand, delays the afternoon peak time and produces more precipitation in the early morning, due to more realistic gradual transition between shallow and deep convection. MMF appears to be able to realistically capture the observed increase of relative humidity prior to deep convection, especially with its two-moment configuration. In contrast, in CAM5 and CAM5 with CLUBB, occurrence of deep convection in these models appears to be a result of stronger heating rather than higher relative humidity.

58 GEOSCIENCES↗

Diagnosing Cloud Biases in the GFDL AM3 Model With Atmospheric Classification

In this paper, we define a set of 21 atmospheric states, or recurring weather patterns, for a region surrounding the Atmospheric Radiation Measurement Program's Southern Great Plains site using an iterative clustering technique. The states are defined using dynamic and thermodynamic variables from reanalysis, tested for statistical significance with cloud radar data from the Southern Great Plains site, and are determined every 6 h for 14 years, creating a time series of atmospheric state. The states represent the various stages of the progression of synoptic systems through the region (e.g., warm fronts, warm sectors, cold fronts, cold northerly advection, and high-pressure anticyclones) with a subset of states representing summertime conditions with varying degrees of convective activity. We use the states to classify output from the NOAA/Geophysical Fluid Dynamics Laboratory AM3 model to test the model's simulation of the frequency of occurrence of the states and of the cloud occurrence during each state. The model roughly simulates the frequency of occurrence of the states but exhibits systematic cloud occurrence biases. Comparison of observed and model-simulated International Satellite Cloud Climatology Project histograms of cloud top pressure and optical thickness shows that the model lacks high thin cloud under all conditions, but biases in thick cloud are state-dependent. Frontal conditions in the model do not produce enough thick cloud, while fair-weather conditions produce too much. Finally, we find that increasing the horizontal resolution of the model improves the representation of thick clouds under all conditions but has little effect on high thin clouds. However, increasing resolution also changes the distribution of states, causing an increase in total cloud occurrence bias.

54 ENVIRONMENTAL SCIENCES↗

Bias‐Dependent Quantum Efficiency Reveals Recombination Pathways in Thin Film Solar Cells

Identifying where recombination predominantly occurs—whether at the front interface, back interface, or throughout the bulk—is crucial for optimizing CdSeTe solar cells and many other photovoltaic device architectures. Here, a simple and effective diagnostic is demonstrated: measuring external quantum efficiency (QE) under varying forward biases. The drift–diffusion simulations reveal that each recombination pathway leaves a distinct bias-induced signature in the normalized QE: a progressive drop at long wavelengths for back-limited devices, a short-wavelength decline for front-limited devices, and a relatively uniform decrease across all wavelengths for bulk-limited devices. These predictions are validated with experiments on As-doped and Cu-doped CdSeTe devices, with and without passivation layers or different front buffers. In each case, the observed bias-dependent QE spectral changes align with the simulated recombination map. Because this method uses standard QE instrumentation, it offers a broadly accessible and cost-efficient means to diagnose recombination pathways—extending beyond CdSeTe to other thin-film and emerging solar cell technologies. By pinpointing recombination bottlenecks, researchers and manufacturers can strategically refine doping profiles, passivation schemes, and interface designs to further improve device performance.

CdTe↗

Behavior of Na and RbF-Treated CdS/Cu(In,Ga)Se 2 Solar Cells with Stress Testing under Heat, Light, and Junction Bias

In this work, the effects of Na and RbF alkali treatment on the metastability behavior of CdS/Cu(In,Ga)Se 2 solar cells are investigated with stress factors of heat, junction bias, and illumination. Four device types with and without Na or RbF treatments are subjected to heat- and light-soaking under open- and short-circuit (OC, SC) junction bias. Low-Na devices show a higher bandgap due to increased minimum Ga content, higher recombination current, and lower open-circuit voltage (V OC ). Devices with RbF post-deposition treatment (PDT) show an improvement in net doping density ≈10 16 cm –3 , V OC , and efficiency. Heat- and light-soaking under OC junction bias provokes an increase in net carrier concentration and V OC irrespective of the alkali treatments. After SC stress, a decrease in V OC and net carrier concentration is observed, which can be stabilized by RbF-PDT. An increase in Na and oxygen concentration in CIGS is observed for baseline and low-Na devices, respectively, after OC stress. The oxygen concentration in CdS decreases after heat- and light-soaking for devices without RbF-PDT, whereas it remains unchanged for devices with RbF-PDT. The atomic concentration profiles in CIGS significantly stabilize as a function of stress with the addition of RbF-PDT.

14 SOLAR ENERGY↗

Analysis of Fe Nanoparticles Using XPS Measurements Under D.C. or Pulsed-Voltage Bias

The impact of solution exposure on the charging properties of oxide coatings on Fe metal-core oxide-shells has been examined by sample biasing during XPS measurements. The Fe nanoparticles were suspended in relatively unreactive acetone and were analyzed after particle containing solutions were deposited on SiO2/Si substrates, and/or Au substrates. The particle and substrate combinations were subjected to ± 10V d.c. biasing in the form of square waves (SQW) pulses with 5V amplitude. The samples experienced variable degrees of charging for which low energy electrons at ~1 eV, 20μA and low energy Ar+ ions were used to minimize. Application of d.c. bias and/or square wave pulses drastically influences the extent of charging, which is utilized to gather additional analytical information about the sample under investigation. This approach allows separation of otherwise overlapping peaks. Accordingly, the O1s peaks of the silicon oxide substrate, the iron oxide nanoparticles, and that of the casting solvent can be separated from each other. Similarly the C1s peak belonging to the solvent can be separated from that of the adventitious carbon. The charging shifts of the iron nanoparticles are strongly influenced by the surrounding solvent. Hence, acetone exhibits the largest shift, water the smallest, and methanol in between. Dynamical measurements performed by application of the voltage stress in the form of SQW pulses gives information about the time constants of the processes involved, which led us postulate that these charging properties we probe in these systems, stem mainly from ionic movement(s).

36 MATERIALS SCIENCE↗

Frequency Limitation Due to Switching Transition of the Bias Current in Bidirectional RSFQ Logic

Switching time limitations of the ac bias current of Josephson junctions in bidirectional rapid single flux quantum (RSFQ) logic circuits are investigated in order to determine the limits to the maximum possible operating frequency. We introduce a new approach based on modifying the bias current parameters and determining the inductance values in the circuit for reducing the switching transition time of the bias current through the junctions. We have simulated and optimized the timing and the operation of the bidirectional nondestructive readout and Josephson transmission line cells in this respect to demonstrate the results of utilizing the proposed approach. We successfully reduced the unwanted spike-type signals across the inductances which are made through the transitions during the fast switching times limiting the operation frequency. This is while we have also removed the consequent destructive spikes at the output. We have included the effects of other determining parameters of the circuit in this investigation and found their relatively optimal values to improve the temporal behavior of the bidirectional RSFQ cells. The results of the proposed approach leading to the fastest possible operation of the considered gates obtained in this work are thoroughly reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle Size-Dependent Zero-Field Exchange Bias in LaFeO {sub 3} Nanoparticles

The present communication deals with particle size-dependent zero-field cooled exchange effect in LaFeO{sub 3} (LFO). LFO nanoparticles were prepared by PVA-based sol-gel method. The sample was calcined at different temperatures (700, 750, and 800 {sup ∘}C) to tune the average particle size. The detailed crystal structural and their geometrical parameters were examined by means of Rietveld refinement using x-ray diffraction data. The different techniques such as Scherrer’s method, Williamson Hall method, FESEM, and TEM were applied to accurately determine the average particle size. Zero-field cooled exchange bias and weak ferromagnetism in antiferromagnetic nanoparticles was observed for all samples using hysteresis loop measurement. The training effect was studied to confirm that the loop shift originates due to exchange bias. Exchange bias as well as coercivity are strongly related to the particle size at low and room temperature. The results clearly demonstrate that the process of calcination tailor the overall properties of material which makes it a promising candidate for device applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Influence of Bias Current on Off-Diagonal Magnetoimpedance in Composite Wires

The off-diagonal magnetoimpedance in a composite wire consisting of a highly conductive inner core covered by a soft magnetic layer is studied theoretically. In the presence of bias current, the field dependence of the off-diagonal magnetoimpedance becomes asymmetric due to the combination of the circular magnetic field produced by the bias current and a helical anisotropy in the magnetic layer of the composite wire. The dependences of the asymmetric off-diagonal magnetoimpedance on the external field, frequency, and bias current are investigated. It is demonstrated that the off-diagonal magnetoimpedance in composite wires has high field sensitivity and exhibits nearly linear behavior at low external fields. The influence of the wire parameters such as the anisotropy axis angle, the magnetic layer thickness, and conductivity on the field sensitivity of the off-diagonal magnetoimpedance is analyzed. The results obtained may be useful for development of weak magnetic-field sensors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗