Search NASA⌕ Search

SEARCH · Search NASA

Results for “calibration source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Science camera calibration for extreme adaptive optics

The nascent field of planet detection has yielded a host of extra-solar planet detections. To date, these detections have been the result of indirect techniques: the planet is inferred by precisely measuring its effect on the host star. Direct observation of extra-solar planets remains a challenging yet compelling goal. In this vein, the Center for Adaptive Optics has proposed a ground-based, high-actuator density extreme A0 system (XAOPI), for a large (~10 m) telescope whose ultimate goal is to directly evidence a specific class of these objects: young and massive planets. Detailed system wave-front error budgets suggest that this system is a feasible, if not an ambitious, proposition. One key element in this error budget is the calibration and maintenance of the science camera wave front with respect to the wave-front sensor which currently as an allowable contribution of ~ 5 nanometers rms. This talk first summarizes the current status of calibration on existing ground-based A0 systems, the magnitude of this effect in the system error budget and current techniques for mitigation. Subsequently, we will explore the nature of this calibration error term, it's source in the non-commonality between the science camera and wave front sensor, and the effect of the temporal evolution of non-commonality. Finally, we will describe preliminary plans for sensing and controlling this error term. The sensing techniques include phase retrieval, phase contrast and external metrology. To conclude, a calibration scenario that meets the stringent requirement for XAOPI will be discussed.

MacIntosh, Bruce↗

Landsat Data Continuity Mission Calibration and Validation

The primary payload for the Landsat Data Continuity Mission (LDCM) is the Operational Land Imager (OLI), being built by Ball Aerospace and Technologies, under contract to NASA. The OLI has spectral bands similar to the Landsat-7 ETM+, minus the thermal band and with two new bands, a 443 nm band and 1375 nm cirrus detection band. On-board calibration systems include two solar diffusers (routine and pristine), a shutter and three sets of internal lamps (routine, backup and pristine). Being a pushbroom opposed to a whiskbroom design of ETM+, the system poses new challenges for characterization and calibration, chief among them being the large focal plane with 75000+ detectors. A comprehensive characterization and calibration plan is in place for the instrument and the data throughout the mission including Ball, NASA and the United States Geological Survey, which will take over operations of LDCM after on-orbit commissioning. Driving radiometric calibration requirements for OLI data include radiance calibration to 5% uncertainty (1 q); reflectance calibration to 3% uncertainty (1 q) and relative (detector-to-detector) calibration to 0.5% (J (r). Driving geometric calibration requirements for OLI include bandto- band registration of 4.5 meters (90% confidence), absolute geodetic accuracy of 65 meters (90% CE) and relative geodetic accuracy of 25 meters (90% CE). Key spectral, spatial and radiometric characterization of the OLI will occur in thermal vacuum at Ball Aerospace. During commissioning the OLI will be characterized and calibrated using celestial (sun, moon, stars) sources and terrestrial sources. The USGS EROS ground processing system will incorporate an image assessment system similar to Landsat-7 for characterization and calibration. This system will have the added benefit that characterization data will be extracted as part of the normal image data processing, so that the characterization data available will be significantly larger than for Landsat-7 ETM+.

Markham, Brian L.↗

Absolute Radiometric Calibration of EUNIS-06

The Extreme-Ultraviolet Normal-Incidence Spectrometer (EUNIS) is a soundingrocket payload that obtains imaged high-resolution spectra of individual solar features, providing information about the Sun's corona and upper transition region. Shortly after its successful initial flight last year, a complete end-to-end calibration was carried out to determine the instrument's absolute radiometric response over its Longwave bandpass of 300 - 370A. The measurements were done at the Rutherford-Appleton Laboratory (RAL) in England, using the same vacuum facility and EUV radiation source used in the pre-flight calibrations of both SOHO/CDS and Hinode/EIS, as well as in three post-flight calibrations of our SERTS sounding rocket payload, the precursor to EUNIS. The unique radiation source provided by the Physikalisch-Technische Bundesanstalt (PTB) had been calibrated to an absolute accuracy of 7% (l-sigma) at 12 wavelengths covering our bandpass directly against the Berlin electron storage ring BESSY, which is itself a primary radiometric source standard. Scans of the EUNIS aperture were made to determine the instrument's absolute spectral sensitivity to +- 25%, considering all sources of error, and demonstrate that EUNIS-06 was the most sensitive solar E W spectrometer yet flown. The results will be matched against prior calibrations which relied on combining measurements of individual optical components, and on comparisons with theoretically predicted 'insensitive' line ratios. Coordinated observations were made during the EUNIS-06 flight by SOHO/CDS and EIT that will allow re-calibrations of those instruments as well. In addition, future EUNIS flights will provide similar calibration updates for TRACE, Hinode/EIS, and STEREO/SECCHI/EUVI.

Thomas, R. J.↗

Methodology for Digital Image Correlation and Infrared Measurement of Melting Aluminum Bars

Ultimately, our experiment measures two quantities on an aluminum bar: motion (which modeling must predict) and temperature (which sets thermal boundary conditions). For motion, stereo DIC is a technique to use imaging data to provide displacements relative to a reference image down to 1/100th of a pixel. We use a calibrated infrared imaging method for accurate temperature measurements. We will be capturing simultaneous data and then registering temperature data in space to the same coordinate system as the displacement data. While we will later show that our experiments are repeatable, indicating that separate experiments for motion and temperature would provide similar data, the simultaneous and registered data removes test to test variability as a source of uncertainty for model calibration and reduces the number of time-consuming tests that must be performed.

36 MATERIALS SCIENCE↗

A practical approach to determining the uncertainty of a pressure measurement system

The pressure measurement systems located at three propulsion component test stands at the Marshall Space Flight Center (MSFC) were evaluated for their specific measurement uncertainty levels. An elemental error source evaluation was performed to provide an analytical estimate of uncertainty. Applied loads tests were also conducted at the different MSFC test sites to derive an empirical estimate of uncertainty for the measurement system process. The analytical results are compared to those obtained empirically. The data from MFSC was also compared to data reported from other comparable test facilities. Methods for acquiring and processing the data from calibration, acquisition, and reduction error sources are also addressed.

Fish, James E.↗

Calibration of the aerodynamic coefficient identification package measurements from the shuttle entry flights using inertial measurement unit data

The Aerodynamic Coefficient Identification Package (ACIP) is an instrument consisting of body mounted linear accelerometers, rate gyros, and angular accelerometers for measuring the Space Shuttle vehicular dynamics. The high rate recorded data are utilized for postflight aerodynamic coefficient extraction studies. Although consistent with pre-mission accuracies specified by the manufacturer, the ACIP data were found to contain detectable levels of systematic error, primarily bias, as well as scale factor, static misalignment, and temperature dependent errors. This paper summarizes the technique whereby the systematic ACIP error sources were detected, identified, and calibrated with the use of recorded dynamic data from the low rate, highly accurate Inertial Measurement Units.

Heck, M. L.↗

In situ calibration of charged particle spectrometers on the OMEGA Laser Facility using 241 Am and 226 Ra sources

Charged particle spectrometry is a critical diagnostic to study inertial-confinement-fusion plasmas and high energy density plasmas. The OMEGA Laser Facility has two fixed magnetic charged particle spectrometers (CPSs) to measure MeV-ions. In situ calibration of these spectrometers was carried out using 241 Am and 226 Ra alpha emitters. The alpha emission spectrum from the sources was measured independently using surface-barrier detectors (SBDs). The energy dispersion and broadening of the CPS systems were determined by comparing the CPS measured alpha spectrum to that of the SBD. The calibration method significantly constrains the energy dispersion, which was previously obtained through the measurement of charged particle fusion products. Overall, a small shift of 100 keV was observed between previous and the calibration done in this work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-fidelity thermal modeling of laser powder bed additive manufacturing

Laser powder bed fusion (LPBF) Additive manufacturing (AM) has attracted interest as an agile method of building production metal parts to reduce design-build-test cycle times for systems. However, predicting part performance is difficult due to inherent process variabilities. This makes qualification challenging. Computational process models have attempted to address some of these challenges, including mesoscale, full physics models and reduced fidelity conduction models. The goal of this work is credible multi-fidelity modeling of the LPBF process by investigating methods for estimating the error between models of two different fidelities. Two methods of error estimation are investigated, adjoint-based error estimation and Bayesian calibration. Adjoint-based error estimation is found to effectively bounding the error between the two models, but with very conservative bounds, making predictions highly uncertain. Bayesian parameter calibration applied to conduction model heat source parameters is found to effectively bound the observed error between the models for melt pool morphology quantities of interest. However, the calibrations do not effectively bound the error in heat distribution.

36 MATERIALS SCIENCE↗

Preliminary Calibration Report of an Apparatus to Measure Vibration Characteristics of Low Frequency Disturbance Source Devices

This report presents a description of the test apparatus and the method of testing the low frequency disturbance source characteristics of small pumps, fans, camera motors, and recorders that are typical of those used in microgravity science facilities. The test apparatus will allow both force and acceleration spectra of these disturbance devices to be obtained from acceleration measurements over the frequency range from 2 to 300 Hz. Some preliminary calibration results are presented.

Russell, James W.↗

A XMM-Newton Observation of Nova LMC 1995, a Bright Supersoft X-ray Source

Nova LMC 1995, previously detected during 1995-1998 with ROSAT, was observed again as a luminous supersoft X-ray source with XMM-Newton in December of 2000. This nova offers the possibility to observe the spectrum of a hot white dwarf, burning hydrogen in a shell and not obscured by a wind or by nebular emission like in other supersoft X-ray sources. Notwithstanding uncertainties in the calibration of the EPIC instruments at energy E<0.5 keV, using atmospheric models in Non Local Thermonuclear Equilibrium we derived an effective temperature in the range 400,000-450,000 K, a bolometric luminosity Lbolabout equal to 2.3 times 10 sup37 erg s sup-l, and we verified that the abundance of carbon is not significantly enhanced in the X-rays emitting shell. The RGS grating spectra do not show emission lines (originated in a nebula or a wind) observed for some other supersoft X-ray sources. The crowded atmospheric absorption lines of the white dwarf cannot be not resolved. There is no hard component (expected from a wind, a surrounding nebula or an accretion disk), with no counts above the background at E>0.6 keV, and an upper limit Fx,hard = 10 sup-14 erg s sup-l cm sup-2 to the X-ray flux above this energy. The background corrected count rate measured by the EPIC instruments was variable on time scales of minutes and hours, but without the flares or sudden obscuration observed for other novae. The power spectrum shows a peak at 5.25 hours, possibly due to a modulation with the orbital period. We also briefly discuss the scenarios in which this nova may become a type Ia supernova progenitor.

Orio, Marina↗

Energy calibration of germanium detectors for the Majorana Demonstrator

The Majorana Demonstrator was a search for neutrinoless double-beta decay (0νββ) in the 76 Ge isotope. It was staged at the 4850-foot level of the Sanford Underground Research Facility (SURF) in Lead, SD. The experiment consisted of 58 germanium detectors housed in a low background shield and was calibrated once per week by deploying a 228 Th line source for 1 to 2 hours. The energy scale calibration determination for the detector array was automated using custom analysis tools. We describe the offline procedure for calibration of the Demonstrator germanium detectors, including the simultaneous fitting of multiple spectral peaks, estimation of energy scale uncertainties, and the automation of the calibration procedure.

47 OTHER INSTRUMENTATION↗

The Clouds and the Earth's Radiant Energy System (CERES) Sensors and Preflight Calibration Plans

The Clouds and the Earth's Radiant Energy System (CERES) spacecraft sensors are designed to measure broadband earth-reflected solar shortwave (0.3-5 microns) and earth-emitted longwave (5- > 100 microns) radiances at the top of the atmosphere as part of the Mission to Planet Earth program. The scanning thermistor bolometer sensors respond to radiances in the broadband shortwave (0.3-5 microns) and total-wave (0.3- > 100 microns) spectral regions, as well as to radiances in the narrowband water vapor window (8-12 microns) region. 'ne sensors are designed to operate for a minimum of 5 years aboard the NASA Tropical Rainfall Measuring Mission and Earth Observing System AM-1 spacecraft platforms that are scheduled for launches in 1997 and 1998, respectively. The flight sensors and the in-flight calibration systems will be calibrated in a vacuum ground facility using reference radiance sources, tied to the international temperature scale of 1990. The calibrations will be used to derive sensor gains, offsets, spectral responses, and point spread functions within and outside of the field of view. The shortwave, total-wave, and window ground calibration accuracy requirements (1 sigma) are +/-0.8, +/-0.6, and +/-0.3 W /sq m/sr, respectively, while the corresponding measurement precisions are +/-O.5% and +/-1.0% for the broadband longwave and shortwave radiances, respectively. The CERES sensors, in-flight calibration systems, and ground calibration instrumentation are described along with outlines of the preflight and in-flight calibration approaches.

Lee, Robert B., III↗

Earth Orientation Effects on Mobile VLBI Baselines

Improvements in data quality for the mobile VLBI systems have placed higher accuracy requirements on Earth orientation calibrations. Errors in these calibrations may give rise to systematic effects in the nonlength components of the baselines. Various sources of Earth orientation data were investigated for calibration of Mobile VLBI baselines. Significant differences in quality between the several available sources of UT1-UTC were found. It was shown that the JPL Kalman filtered space technology data were at least as good as any other and adequate to the needs of current Mobile VLBI systems and observing plans. For polar motion, the values from all service suffice. The effect of Earth orientation errors on the accuracy of differenced baselines was also investigated. It is shown that the effect is negligible for the current mobile systems and observing plan.

Allen, S. L.↗

Smc-Last Point Source Catalog Spitzer'S Last Survey of the Small Magellanic Cloud

We present a processing for the point source catalog derived from Spitzer's final two surveys of the Small Magellanic Cloud (SMC). These 2017-2018 maps duplicate the footprint from the SAGE-SMC program from 2008 and were obtained at 3.6 and 4.5 μm with the Infrared Array Camera (IRAC). They provide a nearly 10-year baseline of all observations of the SMC made by Spitzer. We extracted point sources from both the basic calibrated data (BCD) as well as the final processed mosaics. We did not use any prior catalogs as inputs in order to search for moving objects (e.g., foreground brown dwarfs) and other transient phenomena. The extractions from two test fields are shown here: a field sparsely populated with stars and a second containing more complicated structures. Comparing our extractions between both of our epochs and with the SAGE epochs shows the completeness and range of our survey. The mosaics are currently available on the Infrared Science Archive (IRSA) and the Harvard Dataverse. The final point source catalog will be available at both archives, as well. This work is supported by NASA Award 80NSSC19K0585.

Thomas Kuchar↗

Correlation of ERTS-1 and aircraft optical data with water quality parameters of Charlotte Amalie Harbor, St. Thomas, Virgin Islands

The author has identified the following significant results. Attempts to correlate optical aircraft remote sensing of water quality with the optical data from the ERTS-1 satellite using calibrated imagery of Charlotte Amalie harbor, St. Thomas, Virgin Islands are reported. The harbor at Charlotte Amalie has a concentration of a number of factors affecting water quality: untreated sewage, land runoff, and sediment from navigation and dredging operations. Calibration procedures have been originated and applied to ERTS-1 and I2S camera imagery. The results indicate that the ERTS-1 and I2S imagery are correlated with optical in situ measurements of the harbor water. The aircraft green photographic and ERTS-1 MSS-4 bands have been found most suitable for monitoring the scattered light levels under the conditions of the investigation. The chemical parameters of the harbor water were found to be correlated to the optical properties for two stations investigated in detail. The biological properties of the harbor water (chlorophyll and carotenoids), correlate inversely with the optical data near the pollution sources compared to further away. Calibration procedures developed in this investigation were essential to the interpretation of the photographic and ERTS-1 photometric responses.

Coulbourn, W. C.↗

Sea WiFS Technical Report Series: The fourth SeaWIFS Intercalibration Round-Robin Experiment (SIRREX-4), May 1995

This report documents the fourth Sea-viewing Wide Field-of-view Sensor (SeaWiFS) Intercalibration Round-Robin Experiment (SIRREX-4), which was held at the National Institute of Standards and Technology (NIST) on 3-10 May 1995. The agenda for SIRREX-4 was established by a consensus reached at the conclusion of SIRREX-3: there should be an emphasis on training and work to foster and encourage uniform use of accepted protocols for calibrating radiometric instruments in the laboratory. The goal was to host the activity in a setting where proper techniques could be discussed and demonstrated. It seemed appealing to split the day between morning lectures and afternoon laboratory exercises or practicals. The former gave the user community a chance to present what was important to them and discuss it with acknowledged experts in radiometry, while the latter presented a unique opportunity for training and evaluation in the presence of these same experts. The five laboratory sessions were concerned with (1) determining the responsivity of a spectroradiometer and the spectral radiance of an unknown integrating sphere source, (2) demonstrating spectral field calibration procedures for an integrating sphere using three different instruments, (3) measuring spectral radiance using the plaque method, (4) setting up and aligning lamp calibration transfer standards using the NIST specifications for irradiance measurements, and (5) characterizing radiometric instruments. In addition to documenting some supplemental studies performed outside the laboratory sessions, this report includes an evaluation of the hardware that has been used during the SIRREX activities plus a critical evaluation of SIRREX objectives.

Johnson, B. Carol↗

Wavelet transform analysis of the small-scale X-ray structure of the cluster Abell 1367

We have developed a new technique based on a wavelet transform analysis to quantify the small-scale (less than a few arcminutes) X-ray structure of clusters of galaxies. We apply this technique to the ROSAT position sensitive proportional counter (PSPC) and Einstein high-resolution imager (HRI) images of the central region of the cluster Abell 1367 to detect sources embedded within the diffuse intracluster medium. In addition to detecting sources and determining their fluxes and positions, we show that the wavelet analysis allows a characterization of the sources extents. In particular, the wavelet scale at which a given source achieves a maximum signal-to-noise ratio in the wavelet images provides an estimate of the angular extent of the source. To account for the widely varying point response of the ROSAT PSPC as a function of off-axis angle requires a quantitative measurement of the source size and a comparison to a calibration derived from the analysis of a Deep Survey image. Therefore, we assume that each source could be described as an isotropic two-dimensional Gaussian and used the wavelet amplitudes, at different scales, to determine the equivalent Gaussian Full Width Half-Maximum (FWHM) (and its uncertainty) appropriate for each source. In our analysis of the ROSAT PSPC image, we detect 31 X-ray sources above the diffuse cluster emission (within a radius of 24 min), 16 of which are apparently associated with cluster galaxies and two with serendipitous, background quasars. We find that the angular extents of 11 sources exceed the nominal width of the PSPC point-spread function. Four of these extended sources were previously detected by Bechtold et al. (1983) as 1 sec scale features using the Einstein HRI. The same wavelet analysis technique was applied to the Einstein HRI image. We detect 28 sources in the HRI image, of which nine are extended. Eight of the extended sources correspond to sources previously detected by Bechtold et al. Overall, using both the PSPC and the HRI observations, we detect 16 extended features, of which nine have galaxies coincided with the X-ray-measured positions (within the positional error circles). These extended sources have luminosities lying in the range (3 - 30) x 10(exp 40) ergs/s and gas masses of approximately (1 - 30) x 10(exp 9) solar mass, if the X-rays are of thermal origin. We confirm the presence of extended features in A1367 first reported by Bechtold et al. (1983). The nature of these systems remains uncertain. The luminosities are large if the emission is attributed to single galaxies, and several of the extended features have no associated galaxy counterparts. The extended features may be associated with galaxy groups, as suggested by Canizares, Fabbiano, & Trinchieri (1987), although the number required is large.

Grebeney, S. A.↗

Characterization of B255 R183 C-Cell Cobalt-60 Irradiator Pool

Characterization of the Radiation Calibration and Spectroscopy Laboratory (RCS) Co-60 source radiation pool was successfully completed. The characterization was done by performing several measurements of dose rate in the center of the Co-60 source radiation pool and at multiple heights from the bottom of the pool. The measurements were taken between November 2018 through January 2019. Opti-Chromic FWT-70-40M dosimeters were used for this measurement. A 7.3 cm inner diameter stainless steel cylinder (vessel) was used to lower the dosimeters to the bottom of the pool inside the 16 cm dimeter Co-60 source basket. The dose rate was measured at heights of 5.5, 12, 19, and 23 cm from the bottom of the pool. The report “Tour of the Standards and Calibration Laboratory” includes information about the Co-60 source radiation pool. The importance of performing the Co-60 source characterization is to confirm previously reported Co-60 source dose rate measurements and to provide a documented measuring procedure for researchers and others who want to use the Co-60 source to evaluate the effects of radiation on space-based equipment for other applications. The measured dose rate at the abovementioned heights was 0.65, 0.69, 0.53, 0.23 krad/min respectively with the highest coefficient of variation of less than 10%.

61 RADIATION PROTECTION AND DOSIMETRY↗