Polymeric heat pipe wick

A wick for use in a capillary loop pump heat pipe is described. The wick material is an essentially uniformly porous, permeable, open-cell, polyethylene thermoplastic foam having an ultrahigh average molecular weight of from approximately 1 to 5 million, and an average pore size of about 10 to 12 microns. A representative material having these characteristics is POREX UF, which has an average molecular weight of about 3 million. This material is fully compatible with the FREONs and anhydrous ammonia and allows for the use of these very efficient working fluids in capillary loops.

Seidenberg, Benjamin↗

Characteristics of fluid flow in the combustion synthesis of TiC from the elements

The results of a numerical investigation of finite reservoir effects on capillary spreading at small reservoir dimensions are presently related to wave propagation phenomena in the combustion synthesis of TiC from its two elemental constituents. It is noted that gravitational forces can affect bubble coalescence by nonbuoyant means under the suitable conditions, although these conditions are expected to be rare in combustion synthesis. Finite-curved reservoirs can drive capillary flow due to surface tension and wall contact forces; these cause the wall and the metal to be completely reconfigured during combustion synthesis.

Valone, S. M.↗

Simulation of water vapor condensation on LOX droplet surface using liquid nitrogen

The formation of ice or water layers on liquid oxygen (LOX) droplets in the Space Shuttle Main Engine (SSME) environment was investigated. Formulation of such ice/water layers is indicated by phase-equilibrium considerations under conditions of high partial pressure of water vapor (steam) and low LOX droplet temperature prevailing in the SSME preburner or main chamber. An experimental investigation was begun using liquid nitrogen as a LOX simulant. A monodisperse liquid nitrogen droplet generator was developed which uses an acoustic driver to force the stream of liquid emerging from a capillary tube to break up into a stream of regularly space uniformly sized spherical droplets. The atmospheric pressure liquid nitrogen in the droplet generator reservoir was cooled below its boiling point to prevent two phase flow from occurring in the capillary tube. An existing steam chamber was modified for injection of liquid nitrogen droplets into atmospheric pressure superheated steam. The droplets were imaged using a stroboscopic video system and a laser shadowgraphy system. Several tests were conducted in which liquid nitrogen droplets were injected into the steam chamber. Under conditions of periodic droplet formation, images of 600 micron diameter liquid nitrogen droplets were obtained with the stroboscopic video systems.

Powell, Eugene A.↗

Internally drained condenser for spacecraft thermal management

This paper presents the results obtained to date in a program to develop a high heat flux condenser for use in two-phase spacecraft thermal management loops. The objective is to obtain a several fold increase in condensation heat transfer coefficient over those which can be achieved with shear-controlled or capillary-wick condensers. The internally drained condenser relies on shaped fins to develop a capillary pressure gradient over the surface of the fins and drive the condensate toward narrow drainage grooves separating the fins. The condensate then flows through a drainage network embedded in the condenser walls. Heat transfer coefficients of up to 8 W/sq cm C were measured in steam, providing a heat transfer enhancement ratio greater than a factor of 8. In the paper the proof-of-concept experiments are described and simplified models to predict the performance of the internally drained condenser are presented.

Valenzuela, Javier A.↗

Vibration isolation technology: Sensitivity of selected classes of space experiments to residual accelerations

Progress performed on each task is described. Order of magnitude analyses related to liquid zone sensitivity and thermo-capillary flow sensitivity are covered. Progress with numerical models of the sensitivity of isothermal liquid zones is described. Progress towards a numerical model of coupled buoyancy-driven and thermo-capillary convection experiments is also described. Interaction with NASA personnel is covered. Results to date are summarized and they are discussed in terms of the predicted space station acceleration environment. Work planned for the second year is also discussed.

Alexander, J. Iwan D.↗

On the temperature of surfaces

The concept of the temperature of a surface is introduced from the viewpoint of the physical chemistry of surfaces. The surface, near surface and microlayer regions of the interface are defined. Most methods measure the temperature of the microlayer or at best the near surface region and may err in representing the surface temperature. Methods based on capillary ripples actually measure the surface temperature since surface tension (or surface tension tensor when a monolayer has been spread or absorbed at the interface) is the main restoring force that controls their propagation. Light scattering methods are described for determining the elevation of very small amplitude capillary waves through the computation of various correlation functions from which the surface tension can be estimated. Procedures for estimating the surface temperature are described.

Mann, J. Adin, Jr.↗

Ceramic heat pipe wick

A wick for use in a capillary loop pump heat pipe is disclosed. The wick material is an essentially uniformly porous, permeable, open-cell, silicon dioxide/aluminum oxide inorganic ceramic foam having a silica fiber ratio, by weight, of about 78 to 22, respectively, a density of 6 lbs/cu ft, and an average pore size of less than 5 microns. A representative material having these characteristics is Lockheed Missile and Space Company, Inc.'s HTP 6-22. This material is fully compatible with the freons and anhydrous ammonia and allows for the use of these very efficient working fluids, and others, in capillary loops.

Seidenberg, Benjamin↗

Low-gravity fluid physics: A program overview

An overview is presented of the microgravity fluid physics program at Lewis Research Center. One of the main reasons for conducting low gravity research in fluid physics is to study phenomena such as surface tension, interfacial contact angles, and diffusion independent of such gravitationally induced effects as buoyant convection. Fluid physics is at the heart of many space-based technologies including power systems, thermal control systems, and life support systems. Fundamental understanding of fluid physics is a key ingredient to successful space systems design. In addition to describing ground-based and space-based low-gravity facilities, selected experiments are presented which highlight Lewis work in fluid physics. These experiments can be categorized into five theme areas which summarize the work being conducted at Lewis for OSSA: (1) isothermal/iso-solutal capillary phenomena; (2) capillary phenomena with thermal/solutal gradients; (3) thermal-solutal convection; (4) first- and second-order phase transitions in a static fluid; and (5) multiphase flow.

Source record↗

Vibration isolation technology: Sensitivity of selected classes of experiments to residual accelerations

Work was completed on all aspects of the following tasks: order of magnitude estimates; thermo-capillary convection - two-dimensional (fixed planar surface); thermo-capillary convection - three-dimensional and axisymmetric; liquid bridge/floating zone sensitivity; transport in closed containers; interaction: design and development stages; interaction: testing flight hardware; and reporting. Results are included in the Appendices.

Alexander, J. Iwan D.↗

Melt migration in a silicate liquid-olivine system - An experimental test of compaction theory

An experimentally derived melt migration profile is compared with those obtained from compaction theory. A couple is prepared in which a source-for-melt (a disk composed of a silicate glass and olivine) was placed in contact with a sink-for-melt (a disk of polycrystalline olivine) in order to induce melt migration under laboratory conditions. It is noted that melt infiltrates into the sink disk along triple junctions driven by capillary forces. In order to analyze the melt migration profile in terms of compaction theory, the equations developed by McKenzie (1984) to describe porous flow of a liquid in a deformable matrix were modified. The bouyancy force term is replaced with a capillary force term and governing equations are then solved numerically with the initial boundary conditions specified by the experimental design. Also, it is determined that compaction theory provides a good description of the experimental results provided that the permeability of these solid-liquid materials increases linearly with increasing liquid fraction.

Riley, G. N., Jr.↗

Atrial natriuretic factor increases vascular permeability

An increase in central blood volume in microgravity may result in increased plasma levels of atrial natriuretic factor (ANF). In this study, it was determined whether ANF increases capillary permeability to plasma protein. Conscious, bilaterally nephrectomized male rats were infused with either saline, ANF + saline, or hexamethonium + saline over 2 h following bolus injections of (I-125)-albumin and (C-14)-dextran of similar molecular size. Blood pressure was monitored, and serial determinations of hematocrits were made. Animals infused with 1.0 microg/kg per min ANF had significantly higher hematocrits than animals infused with saline vehicle. Infusion of ANF increased the extravasation of (I-125)-albumin, but not (C-14)-dextran from the intravascular compartment. ANF also induced a depressor response in rats, but the change in blood pressure did not account for changes in capillary permeability to albumin; similar depressor responses induced by hexamethonium were not accompanied by increased extravasation of albumin from the intravascular compartment. ANF may decrease plasma volume by increasing permeability to albumin, and this effect of ANF may account for some of the signs and symptoms of space motion sickness.

Lockette, Warren↗

Analytic theory for the selection of Saffman-Taylor fingers in the presence of thin film effects

The present analytic theory for the width selection of Saffman-Taylor (1958) fingers in the presence of the thin film effect establishes that, in the limit of a small capillary number and a small gap-to-width ratio, fingers whose relative width is smaller than 1/2 are possible. It is established that a fully nonlinear analysis is required for this problem in order to obtain even the correct (and rather preliminary) scaling law. The way in which the selection rule for arbitrary small capillary number is obtainable is also presented.

Tanveer, S.↗

Modeling the use of a binary mixture as a control scheme for two-phase thermal systems

Two-phase thermal loops using mechanical pumps, capillary pumps, or a combination of the two have been chosen as the main heat transfer systems for the space station. For these systems to operate optimally, the flow rate in the loop should be controlled in response to the vapor/liquid ratio leaving the evaporator. By substituting a mixture of two non-azeotropic fluids in place of the single fluid normally used in these systems, it may be possible to monitor the temperature of the exiting vapor and determine the vapor/liquid ratio. The flow rate would then be adjusted to maximize the load capability with minimum energy input. A FLUINT model was developed to study the system dynamics of a hybrid capillary pumped loop using this type of control and was found to be stable under all the test conditions.

Benner, S. M.↗

Training-induced alterations in young and senescent rat diaphragm muscle

The effect of progressive treadmill exercise on oxidative capacity in three specific diaphragm muscle fiber types and on the capillary density of known fiber types was investigated in young (5 month) and senescent (23 months or older) rats. All animals were trained for 1 hr/day, 5 days weekly, for 10 weeks. Measurements of succinate dehydrogenase activity showed significant increases in all three fiber types in both the young and the senescent trained animals, compared with their sedentary controls. Fiber size and capillary density were not affected by exercise or age. The results demonstrate that the senescent costal diaphragm maintains its ability to adapt to an increased metabolic demand brought about by locomotor exercises.

Gosselin, Luc E.↗

Test results of prototype two-phase reservoirs for the CAPL flight experiment

The Capillary Pumped Loop Flight Experiment (CAPL) was designed to test components being considered for inclusion in the Earth Observing System (EOS) instrument thermal control system. The thermal operating conditions of a capillary pumped loop (CPL) heat transport system are controlled by a two-phase reservoir. Three prototype two-phase reservoirs designed for use in microgravity applications were built to CAPL specifications and performance tested at NASA Goddard Space Flight Center using anhydrous ammonia as the working fluid. Test results for liquid expulsion rates and CPL operational control are presented for each reservoir.

Buchko, Matthew T.↗

Similarity rules in gravity jitter-related spacecraft liquid propellant slosh waves excitation

The dynamical behavior of fluids, in particular the effect of surface tension on partially filled rotating fluids in a full-scale prototype Gravity Probe-B Spacecraft propellant tank and various 10 percent subscale containers with identical values of similarity parameters such as Bond number, dynamical capillary number, rotational Reynolds number, and Weber number, as well as imposed gravity jitters have been investigated. It is shown that the Bond number can be used to simulate the wave characteristics of slosh wave excitation, whereas the Weber number can be used to simulate the wave amplitude of slosh-mode excitation. It is shown that a dynamical capillary number can be used to simulate the induced perturbation of the fluid stress distribution exerted on the wall. This distribution is governed by the interaction between surface tension (slosh-wave excitation along the liquid-vapor interface) and viscous (fluid stress exerted on the wall) forces.

Hung, R. J.↗

Observation of intense Stokes and anti-Stokes lines in CH4 pumped by 355 nm of a Nd:YAG laser

The stimulated Raman scattering (SRS) and four-wave mixing (FWM) processes are studied in detail in CH4 gas pumped by the third-harmonic of Nd:YAG laser at 355 nm. The conversion efficiency and average output energy are measured for the various Stokes and anti-Stokes lines at different experimental conditions. The threshold input energy at various CH4 pressures is calculated for the unguided and capillary waveguide Raman cells. The calculated values for the capillary case are compared with the measured values at different CH4 pressures and the two results are in good agreement.

Sentrayan, K.↗

Vaporization heat transfer of dielectric liquids on a wick-covered surface

Vaporization heat transfer characteristics were measured for the dielectric liquid FC-72 on a horizontal heated surface covered with wire screen wicks with the mesh number for the screens varying from 24 to 100. In such a situation the liquid level can be either higher or lower than the heated surface. When the liquid level was above the heated surface (shallow pool boiling), the height of the liquid level above the surface, h, was varied from 0 to 10 mm. When the liquid level was below the heated surface (evaporation through capillary pumping), the distance from the liquid level to the edge of the surface, L, was adjusted from 0 to 15 mm. Experimental data revealed that the critical heat flux (CHF) decreases as the mesh number is increased from 24 to 100 for both vaporation and shallow pool boiling, showing that the vapor-escaping limit is more important than the capillary limit in flat plate heat pipe application.