Search NASA⌕ Search

SEARCH · Search NASA

Results for “collimators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Stimulated Raman and Brillouin Backscattering of Collimated Beams Carrying Orbital Angular Momentum

We study theoretically the exchange of angular momentum between electromagnetic and electrostatic waves in a plasma, due to the stimulated Raman and Brillouin backscattering processes. Angular momentum states for plasmon and phonon fields are introduced for the first time. We demonstrate that these states can be excited by nonlinear wave mixing, associated with the scattering processes. This could be relevant for plasma diagnostics, both in laboratory and in space. Nonlinearly coupled paraxial equations and instability growth rates are derived.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Guiding, Focusing, and Collimated Transport of Hot Electrons in a Canal in the Extended Tip of Cone Targets

Hot electrons are produced, guided into a beam, and transported over 60 {mu}m in a small canal to the outside tip of a structured cone target. The diameter of the electron beam is defined by the inside tip diameter. This carries the potential to create electron beams of specific diameters propagating over specific distances of interest for several applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Self-Organizing GeV, Nanocoulomb, Collimated Proton Beam from Laser Foil Interaction at 7x10{sup 21} W/cm{sup 2}

We report on a self-organizing, quasistable regime of laser proton acceleration, producing 1 GeV nanocoulomb proton bunches from laser foil interaction at an intensity of 7x10{sup 21} W/cm{sup 2}. The results are obtained from 2D particle-in-cell simulations, using a circular polarized laser pulse with Gaussian transverse profile, normally incident on a planar, 500 nm thick hydrogen foil. While foil plasma driven in the wings of the driving pulse is dispersed, a stable central clump with 1-2lambda diameter is forming on the axis. The stabilization is related to laser light having passed the transparent parts of the foil in the wing region and enfolding the central clump that is still opaque. Varying laser parameters, it is shown that the results are stable within certain margins and can be obtained both for protons and heavier ions such as He{sup 2+}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Laser-Driven Fast Electron Collimation in Targets with Resistivity Boundary

We demonstrate experimentally that the relativistic electron flow in a dense plasma can be efficiently confined and guided in targets exhibiting a high-resistivity-core-low-resistivity-cladding structure analogous to optical waveguides. The relativistic electron beam is shown to be confined to an area of the order of the core diameter (50 {mu}m), which has the potential to substantially enhance the coupling efficiency of electrons to the compressed fusion fuel in the Fast Ignitor fusion in full-scale fusion experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comment on "Table-Top Laser-Based Source of Femtosecond, Collimated, Ultrarelativistic Positron Beams"

Sarri et al. have reported the generation of low divergence (~3 mrad), high-density (10 14 cm –3 ) positron beams using millimeter-scale converter targets and a 50 pC, 200 MeV laser-wakefield accelerated (LWFA) electron source. It was argued that the positron divergence was dominated by the pair-production birth cone angle $θ_{e+} ≈ 1/γ_{e–}$. The small, energy-independent divergence value was used to infer a positron beam density of 2 × 10 14 cm –3 from a 4.2 mm Ta converter target where the divergence and yield measurements agreed with their Monte Carlo (MC) simulations. We have repeated these simulations using experimental conditions and disagree with the reported density, divergence, and yield values by up to factors > 50. In our work, we find that a divergence on the order of milliradian is not physical and can only be achieved if inelastic particle scattering is omitted in the calculations.

47 OTHER INSTRUMENTATION↗

Observation of a magneto-Rayleigh-Taylor instability in magnetically collimated plasma jets

We present the direct experimental observation of the formation of a diamagnetic cavity and magneto-Rayleigh-Taylor (MRT) instability in a β ≈ 1 high energy density plasma. Proton radiography is used to measure the two dimensional path-integrated magnetic field in a laser-produced plasma propagating parallel to a preimposed magnetic field. Flutelike structures, associated with the MRT instability, are observed to grow at the surface of the cavity, with a measured wavelength of 1.2 mm and growth time of 4 ns. These measurements are in good agreement with predictions of three dimensional magnetohydrodynamic simulations using the GORGON code. Published by the American Physical Society 2024

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring the Density of Different Materials by Using the Collimated Fast Neutron Beam

It was demonstrated in the previous work that various threat materials could be detected inside the sea going cargo container by measuring the three variables, carbon and oxygen concentration and density of investigated material. Density was determined by measuring transmitted neutrons, which is not always practical in terms of setting up the instrument geometry. In order to enable more geometry flexibility, we have investigated the possibility of using the scattered neutrons in cargo material identification. For that purpose, the densities of different materials were measured depending on the position of neutron detectors and neutron generator with respect to the target position. One neutron detector was put above the target, one behind and one in front of the target, above the neutron generator. It was shown that all three positions of neutron detectors can be successfully used to measure the target density, but only if the detected neutrons are successfully discriminated from the gamma rays. Although the associated alpha particle technique/associate particle imaging (API) was used to discriminate the neutrons from the gamma rays, it is believed that the same results would be obtained by using the pulse shape discrimination method. In that way API technique can be avoided and the neutron generator which produces much higher beam intensity than 10{sup 8} n/s can be used. (authors)

36 MATERIALS SCIENCE↗

Fast, high-resolution 3D dosimetry utilizing a novel optical-CT scanner incorporating tertiary telecentric collimation

This study introduces a charge coupled device (CCD) area detector based optical-computed tomography (optical-CT) scanner for comprehensive verification of radiation dose distributions recorded in nonscattering radiochromic dosimeters. Defining characteristics include: (i) a very fast scanning time of {approx}5 min to acquire a complete three-dimensional (3D) dataset, (ii) improved image formation through the use of custom telecentric optics, which ensures accurate projection images and minimizes artifacts from scattered and stray-light sources, and (iii) high resolution (potentially 50 {mu}m) isotropic 3D dose readout. The performance of the CCD scanner for 3D dose readout was evaluated by comparison with independent 3D readout from the single laser beam OCTOPUS-scanner for the same PRESAGE dosimeters. The OCTOPUS scanner was considered the 'gold standard' technique in light of prior studies demonstrating its accuracy. Additional comparisons were made against calculated dose distributions from the ECLIPSE treatment-planning system. Dose readout for the following treatments were investigated: (i) a single rectangular beam irradiation to investigate small field and very steep dose gradient dosimetry away from edge effects, (ii) a 2-field open beam parallel-opposed irradiation to investigate dosimetry along steep dose gradients, and (iii) a 7-field intensity modulated radiation therapy (IMRT) irradiation to investigate dosimetry for complex treatment delivery involving modulation of fluence and for dosimetry along moderate dose gradients. Dose profiles, dose-difference plots, and gamma maps were employed to evaluate quantitative estimates of agreement between independently measured and calculated dose distributions. Results indicated that dose readout from the CCD scanner was in agreement with independent gold-standard readout from the OCTOPUS-scanner as well as the calculated ECLIPSE dose distribution for all treatments, except in regions within a few millimeters of the edge of the dosimeter, where edge artifact is predominant. Agreement of line profiles was observed, even along steep dose gradients. Dose difference plots indicated that the CCD scanner dose readout differed from the OCTOPUSscanner readout and ECLIPSE calculations by {approx}10% along steep dose gradients and by {approx}5% along moderate dose gradients. Gamma maps (3% dose-difference and 3 mm distance-to-agreement acceptance criteria) revealed agreement, except for regions within 5 mm of the edge of the dosimeter where the edge artifact occurs. In summary, the data demonstrate feasibility of using the fast, high-resolution CCD scanner for comprehensive 3D dosimetry in all applications, except where dose readout is required close to the edges of the dosimeter. Further work is ongoing to reduce this artifact.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-506: Development and Commissioning of the Effective and Efficient Grid Therapy Using High Dose Rate Flattening Filter Free Beam and Multileaf Collimator

Purpose: Treating bulky tumors with grid therapy (GT) has demonstrated high response rates. Long delivery time (∼15min), with consequent increased risk of intrafraction motion, is a major disadvantage of conventional MLC-based GT (MLC-GT). The goal of this study was to develop and commission a MLC-GT technique with similar dosimetric characteristics, but more efficient delivery. Methods: Grid plan was designed with 10X-FFF (2400MU/min) beam and MLC in a commercial treatment planning system (TPS). Grid size was 1cm by 1cm and grid-to-grid distance was 2cm. Field-in-field technique was used to flatten the dose profile at depth of 10cm. Prescription was 15Gy at 1.5cm depth. Doses were verified at depths of 1.5cm, 5cm and 10cm. Point dose was measured with a plastic scintillator detector (PSD) while the planar dose was measured with calibrated Gafchromic EBT3 films in a 20cm think, 30cmx30cm solid water phantom. The measured doses were compared to the doses calculated in the treatment planning system. Percent depth dose (PDD) within the grid was also measured using EBT3 film. Five clinical cases were planned to compare beam-on time. Results: The valley-to-peak dose ratio at the 3 depths was approximately 10–15%, which is very similar to published result. The average point dose difference between the PSD measurements and TPS calculation is 2.1±0.6%. Film dosimetry revealed good agreement between the delivered and calculated dose. The average gamma passing rates at the 3 depths were 95% (3%, 1mm). The average percent difference between the measured PDD and calculated PDD was 2.1% within the depth of 20cm. The phantom plan delivery time was 3.6 min. Average beam-on time was reduced by 66.1±5.6% for the 5 clinical cases. Conclusion: An effective and efficient GT technique was developed and commissioned for the treatment of bulky tumors using FFF beam combined with MLC and automation. The Department of Radiation Oncology at Henry Ford Health System receives research support from Varian Medical Systems and Philips Health Care.

60 APPLIED LIFE SCIENCES↗

Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 02: Feasibility of using multileaf collimation for stereotactic radiosurgery of arteriovenous malformation

SRS using linac and cones offers steep dose fall-off but a tradeoff exists between conformality and treatment time, which depends on the number of isocentres. Purpose of this study is to quantify planning metrics between cones- and MLC-based SRS for arteriovenous malformation(AVM). Seven AVM cases treated with cones were re-planned with MLC on Pinnacle treatment planning system. Planning target volume(PTV) was created with 1mm uniform margin to the AVM to account for MLC positional variation. Clinically-planned prescription dose(15–25Gy) was used. Four plans were generated per case:non-coplanar VMAT(ncV), single-arc VMAT(saV), non-coplanar IMRT(ncI), non-coplanar conformal(ncC). Plans were compared for conformity(CI), heterogeneity(HI) and gradient(GI) indices and brain doses. Estimated treatment times and monitor units(MU) were compared. Cone-based plans required 2–6 isocentres. Though CI-RTOG was similar for plans(median=0.98), CI-Paddick was most favourable for ncV(median=0.86) and worst for cones(0.54). HI for MLC plans(median=1.19–1.27) were lower than cone-based plans(1.43). GI was similar for all plans. For 2/7 ncC had brainstem maximum dose>16.7Gy and therefore were clinically unacceptable. Brain V12Gy,V10Gy,V2Gy were lowest in the cones plan. ncV brain V12Gy,V10Gy,V2Gy were lowest of all MLC-based plans studied. Treatment MUs were similar for MLC-based plans and up to 70% lower than clinically delivered plans. ncV showed best conformality in this study. Of the MLC-based plans, ncV also showed lowest normal tissue dose with reasonable treatment time.

60 APPLIED LIFE SCIENCES↗

Pattern Recognition: The Importance of Dispersion in Crystal Collimation

One aspect of the upcoming CRYSTAL experiment is to study the dynamics of single protons circulating the SPS in the presence of a crystal. Under some circumstances (for example under crystal channeling) a proton may hit the crystal and the neighboring silicon strip position detectors only once, before extraction from the SPS. In general (at most crystal rotation angles) it is expected that single protons will hit the crystal many times, with many accelerator turns between each hit, before escaping. Intermediate regimes are also possible (for example under volume reflection) in which a proton hits the crystal only a few times over many turns before being lost.

43 PARTICLE ACCELERATORS↗

Advanced X-ray Collection and Collimation Optic

Incom Inc. and Brookhaven National Laboratory have a mutual interest in developing and testing an X-ray optic that will function in an advanced detector system. This optic leverages the development work already carried out at Incom in drawing hollow core capillary structures. Incom has developed a revolutionary method for fabricating arrays of hollow capillary structures out of several types of glass and is investigating several market applications for this technology, including large area (9”x9”) microchannel plates for electron amplification, hydrogen storage, and x-ray optics, the subject of this application. Methods have been developed for fabricating hexagonally arranged polycapillaries with outside diameters in the range of .020”-0.25” with capillary internal diameters from 2-350+ µm. Initial trials of capillary tapering have yielded promising results. BNL’s expertise in the development of X-ray optics, especially x-ray spectrometers will be utilized in the development of the unique lens concept and its integration into the spectrometer.

42 ENGINEERING↗

Advanced X-ray Collection and Collimation Optic

To develop and specify a design for a cost-effective, high-resolution x-ray spectrometer and its x-ray lenses is the goal of this proposal. Optimized polycarpellary lenses will be fabricated, characterized and implemented in the spectrometer. Based on the results a system analysis is performed and verified in a feasibility study.

47 OTHER INSTRUMENTATION↗