Search NASA⌕ Search

SEARCH · Search NASA

Results for “consistent filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Galaxy cluster scaling relations between Bolocam Sunyaev–Zel’dovich effect and Chandra X-ray measurements

We present scaling relations between the integrated Sunyaev–Zel’dovich effect (SZE) signal, Y{sub SZ}, its X-ray analogue, Y{sub X} ≡ M{sub gas} T{sub X}, and total mass, M{sub tot}, for the 45 galaxy clusters in the Bolocam X-ray SZ (BOXSZ) sample. All parameters are integrated within r{sub 2500}. Y{sub 2500} values are measured using SZE data collected with Bolocam, operating at 140 GHz at the Caltech Submillimeter Observatory. The temperature, T{sub X}, and mass, M{sub gas,2500}, of the intracluster medium are determined using X-ray data collected with Chandra, and M{sub tot} is derived from M{sub gas} assuming a constant gas mass fraction. Our analysis accounts for several potential sources of bias, including selection effects, contamination from radio point sources, and the loss of SZE signal due to noise filtering and beam-smoothing effects. We measure the Y{sub 2500}–Y{sub X} scaling to have a power-law index of 0.84 ± 0.07, and a fractional intrinsic scatter in Y{sub 2500} of (21±7)% at fixed Y{sub X}, both of which are consistent with previous analyses. We also measure the scaling between Y{sub 2500} and M{sub 2500}, finding a power-law index of 1.06 ± 0.12 and a fractional intrinsic scatter in Y{sub 2500} at fixed mass of (25±9)%. While recent SZE scaling relations using X-ray mass proxies have found power-law indices consistent with the self-similar prediction of 5/3, our measurement stands apart by differing from the self-similar prediction by approximately 5σ. Given the good agreement between the measured Y{sub 2500}–Y{sub X} scalings, much of this discrepancy appears to be caused by differences in the calibration of the X-ray mass proxies adopted for each particular analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

Construction status of the Mu2e crystal calorimeter

The Mu2e experiment at Fermilab will search for the charged-lepton flavor violating neutrino-less conversion of a negative muon into an electron in the field of an aluminum nucleus. The Mu2e detector is composed of a tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter plays an important role in providing excellent particle identification capabilities and a fast online trigger filter, while aiding the track reconstruction capabilities. Calorimeter requirements are to provide a large acceptance for 0~10 MeV electrons and reach: i) a time resolution better than 0.5 ns; ii) an energy resolution better than 10%; and iii) a position resolution of 1 cm. The calorimeter consists of two disks, each one made of 674 pure CsI crystals. Each crystal is readout by two large area 2×3 arrays of UV-extended SiPMs of 6×6 mm2 dimensions. A large scale prototype (Module-0) has been tested at an electron beam. We report here the tests done to finalize the calorimeter design, the results obtained with Module-0 and the status of production. At this time, the performance characteristics of 85% of the crystals and all of the SiPMs have been measured. The calorimeter engineering drawings have been completed and the large mechanical components are under fabrication. Analog and digital electronics have been prototyped and tested with irradiation dose. Their serial production is being organized. The calorimeter assembly phase is planned for mid-2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-142: Performance Study of Automatic Image-Segmentation Algorithms in Motion Tracking Via MR-IGRT

Purpose: Evaluate commonly used segmentation algorithms on a commercially available real-time MR image guided radiotherapy (MR-IGRT) system (ViewRay), compare the strengths and weaknesses of each method, with the purpose of improving motion tracking for more accurate radiotherapy. Methods: MR motion images of bladder, kidney, duodenum, and liver tumor were acquired for three patients using a commercial on-board MR imaging system and an imaging protocol used during MR-IGRT. A series of 40 frames were selected for each case to cover at least 3 respiratory cycles. Thresholding, Canny edge detection, fuzzy k-means (FKM), k-harmonic means (KHM), and reaction-diffusion level set evolution (RD-LSE), along with the ViewRay treatment planning and delivery system (TPDS) were included in the comparisons. To evaluate the segmentation results, an expert manual contouring of the organs or tumor from a physician was used as a ground-truth. Metrics value of sensitivity, specificity, Jaccard similarity, and Dice coefficient were computed for comparison. Results: In the segmentation of single image frame, all methods successfully segmented the bladder and kidney, but only FKM, KHM and TPDS were able to segment the liver tumor and the duodenum. For segmenting motion image series, the TPDS method had the highest sensitivity, Jarccard, and Dice coefficients in segmenting bladder and kidney, while FKM and KHM had a slightly higher specificity. A similar pattern was observed when segmenting the liver tumor and the duodenum. The Canny method is not suitable for consistently segmenting motion frames in an automated process, while thresholding and RD-LSE cannot consistently segment a liver tumor and the duodenum. Conclusion: The study compared six different segmentation methods and showed the effectiveness of the ViewRay TPDS algorithm in segmenting motion images during MR-IGRT. Future studies include a selection of conformal segmentation methods based on image/organ-specific information, different filtering methods and their influences on the segmentation results. Parag Parikh receives research grant from ViewRay. Sasa Mutic has consulting and research agreements with ViewRay. Yanle Hu receives travel reimbursement from ViewRay. Iwan Kawrakow and James Dempsey are ViewRay employees.

60 APPLIED LIFE SCIENCES↗

An online replanning method using warm start optimization and aperture morphing for flattening-filter-free beams

Purpose: In a situation where a couch shift for patient positioning is not preferred or prohibited (e.g., MR-linac), segment aperture morphing (SAM) can address target dislocation and deformation. For IMRT/VMAT with flattening-filter-free (FFF) beams, however, SAM method would lead to an adverse translational dose effect due to the beam unflattening. Here the authors propose a new two-step process to address both the translational effect of FFF beams and the target deformation. Methods: The replanning method consists of an offline and an online step. The offline step is to create a series of preshifted-plans (PSPs) obtained by a so-called “warm start” optimization (starting optimization from the original plan, rather than from scratch) at a series of isocenter shifts. The PSPs all have the same number of segments with very similar shapes, since the warm start optimization only adjusts the MLC positions instead of regenerating them. In the online step, a new plan is obtained by picking the closest PSP or linearly interpolating the MLC positions and the monitor units of the closest PSPs for the shift determined from the image of the day. This two-step process is completely automated and almost instantaneous (no optimization or dose calculation needed). The previously developed SAM algorithm is then applied for daily deformation. The authors tested the method on sample prostate and pancreas cases. Results: The two-step interpolation method can account for the adverse dose effects from FFF beams, while SAM corrects for the target deformation. Plan interpolation method is effective in diminishing the unflat beam effect and may allow reducing the required number of PSPs. The whole process takes the same time as the previously reported SAM process (5–10 min). Conclusions: The new two-step method plus SAM can address both the translation effects of FFF beams and target deformation, and can be executed in full automation except the delineation of target contour required by the SAM process.

60 APPLIED LIFE SCIENCES↗

SUMMARY REPORT FOR ZINC 65 CONTAMINATION CONTROL

Radioactive zinc, {sup 65}Zn, was detected after extraction of 215 TPBARs in from TVA reactor fuel cycle 6. A team consisting of Tritium Engineering, Tritium Operations, Tritium Radiation Control, and Savannah River National Laboratory personnel evaluated the risk and response and developed short, medium and long term goals for contamination control. One of the goals was incorporated into site Performance Based Incentive CO 3.4, to optimize the filter geometry and operating conditions for the Tritium Extraction Facility. This goal included a scoping study to determine if the contamination could be contained within the high radiation environment of the furnace module as well. In order to optimize the filters studies were conducted to independently evaluate the effect of pore size on pumping efficiency and zinc trapping efficiency (1). A study was also conducted to evaluate the effect of temperature on the trapping efficiency and adhesion (2). In addition, the potential for chemically trapping zinc in the lithium trap was evaluated using a thermodynamic study (3) followed by preliminary experimental testing (4). Based on the work that was completed it is determined that a 20 {mu}m filter heated to between 120 and 200 C will act as an effective physical trap for zinc vapors. It may be possible to chemically react zinc with copper or cobalt to form zinc intermetallic compounds or alloys but additional work under more prototypic conditions are required.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Compact and multi-view solid state neutral particle analyzer arrays on National Spherical Torus Experiment-Upgrade

A compact and multi-view solid state neutral particle analyzer (SSNPA) diagnostic based on silicon photodiode arrays has been successfully tested on the National Spherical Torus Experiment-Upgrade. The SSNPA diagnostic provides spatially, temporally, and pitch-angle resolved measurements of fast-ion distribution by detecting fast neutral flux resulting from the charge exchange (CX) reactions. The system consists of three 16-channel subsystems: t-SSNPA viewing the plasma mid-radius and neutral beam (NB) line #2 tangentially, r-SSNPA viewing the plasma core and NB line #1 radially, and p-SSNPA with no intersection with any NB lines. Due to the setup geometry, the active CX signals of t-SSNPA and r-SSNPA are mainly sensitive to passing and trapped particles, respectively. In addition, both t-SSNPA and r-SSNPA utilize three vertically stacked arrays with different filter thicknesses to obtain coarse energy information. The experimental data show that all channels are operational. The signal to noise ratio is typically larger than 10, and the main noise is x-ray induced signal. The active and passive CX signals are clearly observed on t-SSNPA and r-SSNPA during NB modulation. The SSNPA data also indicate significant losses of passing particles during sawteeth, while trapped particles are weakly affected. Fluctuations up to 120 kHz have been observed on SSNPA, and they are strongly correlated with magnetohydrodynamics instabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional feature matching improves coverage for single-cell proteomics based on ion mobility filtering

Single-cell proteomics (scProteomics) promises to advance our understanding of cell functions within complex biological systems. However, a major challenge of current methods is their inability to identify and provide accurate quantitative information for low abundance proteins. Herein, we describe an ion mobility-enhanced mass spectrometry acquisition and peptide identification method, TIFF (Transferring Identification based on FAIMS Filtering), to improve the sensitivity and accuracy of label-free scProteomics. TIFF extends the ion accumulation times for peptide ions by filtering out singly charged ions. The peptide identities are assigned by a three-dimensional MS1 feature matching approach (retention time, accurate mass, and FAIMS compensation voltage). TIFF method enabled unbiased proteome analysis to a depth of >1,700 proteins in single HeLa cells with >1,100 proteins consistently identified. As a demonstration, we applied the TIFF method to obtain temporal proteome profiles of >150 single murine macrophage cells during lipopolysaccharide stimulation and identified time-dependent proteome changes.

59 BASIC BIOLOGICAL SCIENCES↗

OBSERVATIONAL EVIDENCE OF RESONANTLY DAMPED PROPAGATING KINK WAVES IN THE SOLAR CORONA

In this Letter, we establish clear evidence for the resonant absorption damping mechanism by analyzing observational data from the novel Coronal Multi-Channel Polarimeter. This instrument has established that in the solar corona there are ubiquitous propagating low-amplitude ({approx}1 km s{sup -1}) Alfvenic waves with a wide range of frequencies. Realistically interpreting these waves as the kink mode from magnetohydrodynamic wave theory, they should exhibit a frequency-dependent damping length due to resonant absorption, governed by the Terradas-Goossens-Verth relation showing that transverse plasma inhomogeneity in coronal magnetic flux tubes causes them to act as natural low-pass filters. It is found that the observed frequency dependence on damping length (up to about 8 mHz) can be explained by the kink wave interpretation; and furthermore, the spatially averaged equilibrium parameter describing the length scale of transverse plasma density inhomogeneity over a system of coronal loops is consistent with the range of values estimated from Transition Region and Coronal Explorer observations of standing kink modes.

79 ASTRONOMY AND ASTROPHYSICS↗

Data acquisition system for the Baikal-GVD neutrino telescope

The objective of the Baikal-GVD project is the construction of a km{sup 3}-scale neutrino telescope in Lake Baikal. The Gigaton Volume Detector consists of a large three-dimensional array of photo-multiplier tubes. The first GVD-cluster has been deployed and commissioned in April 2015. The data acquisition system (DAQ) of the detector takes care of the digitization of the photo-multiplier tube signals, data transmission, filtering and storage. The design and the implementation of the data acquisition system are described.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Multiobjective and categorical global optimization of photonic structures based on ResNet generative neural networks

Abstract We show that deep generative neural networks, based on global optimization networks (GLOnets), can be configured to perform the multiobjective and categorical global optimization of photonic devices. A residual network scheme enables GLOnets to evolve from a deep architecture, which is required to properly search the full design space early in the optimization process, to a shallow network that generates a narrow distribution of globally optimal devices. As a proof-of-concept demonstration, we adapt our method to design thin-film stacks consisting of multiple material types. Benchmarks with known globally optimized antireflection structures indicate that GLOnets can find the global optimum with orders of magnitude faster speeds compared to conventional algorithms. We also demonstrate the utility of our method in complex design tasks with its application to incandescent light filters. These results indicate that advanced concepts in deep learning can push the capabilities of inverse design algorithms for photonics.

Jiang, Jiaqi↗

Syracuse University Test Report On Uptake Factor Resulting From A Dropped Storage Container

Under certain circumstances, powder from an accidently dropped container can become airborne and inhaled by people nearby such as those who are moving the containers. The inhaled fine particles can deposit on respiratory tracts and lungs, causing asthma, lung cancer, and other acute respiratory illnesses and chronic symptoms. The objective of this study was to develop a standard procedure to measure the airborne concentrations of different size particles within the vicinity of a dropped container where a significant portion of the contained powder is ejected. Tungsten oxide (WO{sub 3}) was selected in this study to represent relatively heavy powders (7.16 g/cm3 specific gravity for WO{sub 3}). A typical can with the outer dimensions of 4.25” diameter and 4.875” tall was used as the container. The powder was dropped in two different configurations: 1) contained within a can covered by a lid that has a 0.25” diameter hole, and 2) contained within a can without a lid. The packing volume of the powder was 51.4 in{sup 3} (842.7 cm{sup 3}) and the target mass was 1936 g. The tests were carried out in a full-scale stainless steel environmental chamber with an interior volume of 852 ft{sup 3} (24.1 m{sup 3}). The chamber system includes an internal recirculation loop with a rectangular air diffuser and 10 variable frequency drive fans to provide a typical room air recirculation flow pattern. Two air filters were installed in the chamber air supply duct and return duct to achieve the required low background particle concentration. The initial chamber air conditions were set at 70°F (± 5°F) and 50% (± 10%) RH. A supporting frame and releasing device were designed and built to trigger consistently the dropping of the can at a height of 8 feet from the bottom of the can to the impacting surface. The particle sampling inlet was placed 5 ft above the floor and 6 inches laterally away from the can’s falling path. Concentrations of particles between 0.5 μm and 20 μm were recorded in units of mass and number of particles per unit volume. The data acquisition rate was once every 2 seconds during the first 2 hours and every 20 seconds thereafter. A test procedure was developed and a total of nine drop tests were performed. In most cases (seven tests), the can tipped over after dropping. The can in Test 1 stayed upright. The can in Test 7 showed a special behavior: after the rebound, it turned upside down and stayed upright. Major findings are summarized below: The amount of spilled powder varied from 0.12 g to 252.35 g and the non-recovered powder varied from 0.11 g to 1.18 g. The corresponding percentage of the spilled powder ranged from 0.01% to 13%;The peak value of particle number concentration after the dropping of the can occurred at approximately 0.9 μm particle size per measured data of individual channels. The peak value of particle mass concentration occurred in the range of 4.3 - 10 μm particle size per grouped data calculated from the measured data with the exception of Test 4 where a different batch powder with unexpectedly different bulk density and particle size distribution; After the dropping of the can, the total airborne mass concentrations ranged from 0.03 to 0.35 mg/m{sup 3}, while the total airborne number concentrations ranged from 2 to 125 #/cm{sup 3} except for Test 4. The number concentration in Test 4 was 1 or 2 orders of magnitude less than those of other tests because the powder was from a different batch. However, its mass concentration was comparable to that in Test 7 because relatively more big airborne particles were detected in Test 4. In general, tests with lid (Test 5, 6, 7 and 8) had smaller concentrations than tests without lid (Test 0, 1, 2, and 3). The influence of lid was not as prominent as the powder (Test 4). However, this needs more tests for verification; The ratio of airborne mass to non-recovered mass ranged from 0.1% to 2%. This means that it is challenging to use this method to check the mass balance, while the uptake factor and associated inhalation exposure can be readily assesse; The calculated cumulative uptake mass within first 10 minutes after the dropping of the can for each test was within the range of 0.002 mg to 0.035 mg. Assuming a breathing rate of 1.2 m{sup 3}/h, the uptake factor during the first 10 minutes was calculated to be between 10{sup -9} and 2×10{sup -8} in reference to the amount loaded; or between 10{sup -8} and 6×10{sup -5} in reference to the amount spilled. The experimental results of this study will be useful for standardizing the test method and provide data for estimating the exposure and associated risk to building occupants in the case of an accidental dropping of heavy powder containers.

42 ENGINEERING↗

Syracuse Univesity Test Report On Uptake Factor Resulting From A Dropped Storage Container - Phase II

Under certain circumstances, powder from an accidently dropped container can become airborne and inhaled by people nearby such as those who are moving the containers. The inhaled fine particles can deposit on respiratory tracts and lungs, causing asthma, lung cancer, and other acute respiratory illnesses and chronic symptoms. The objective of this study was to develop a standard procedure to measure the airborne concentrations of different size particles within the vicinity of a dropped container where a significant portion of the contained powder is ejected. Tungsten oxide (WO 3 ) was selected in this study to represent relatively heavy powders (7.16 g/cm 3 specific gravity for WO 3 ). A typical can with the outer dimensions of 4.25” diameter and 4.875” tall was used as the container. The powder was dropped in two different configurations: 1) contained within a can covered by a lid that has a 0.25” diameter hole, and 2) contained within a can without a lid. The packing volume of the powder was 51.4 in 3 (842.7 cm 3 ) and the target mass was 1936 g. The tests were carried out in a full-scale stainless steel environmental chamber with an interior volume of 852 ft 3 (24.1 m3). The chamber system includes an internal recirculation loop with a rectangular air diffuser and 10 variable frequency drive fans to provide a typical room air recirculation flow pattern. Two air filters were installed in the chamber air supply duct and return duct to achieve the required low background particle concentration. The initial chamber air conditions were set at 70°F (± 5°F) and 50% (± 10%) RH. A supporting frame and releasing device were designed and built to trigger consistently the dropping of the can. The particle sampling inlet was placed 5 ft above the floor and 6 inches laterally away from the can’s falling path. Concentrations of particles between 0.5 μm and 20 μm were recorded in units of mass and number of particles per unit volume. The data acquisition rate was once every 2 seconds during the first 2 hours. A test procedure was developed and verified. A total of thirty two drop tests were performed, eight in Phase I and twenty four in Phase II, covering variations in dropping height (8 ft or 4 ft from the floor), room air movement (0.25-0.30 m/s or 0.10-0.15 m/s near the ceiling), landing scenario (on a flat plate or a block), and lid condition (¼” lid hole or no lid). There were ten tests with flat plate and ¼” lid hole, ten tests with flat plate no lid and twelve tests with block no lid.

42 ENGINEERING↗

K West Basin Sand Filter Backwash Sample Analysis

A sand filter is used to help maintain water clarity at the K West Basin where highly radioactive sludge is stored. Eventually that sand filter will require disposal. The radionuclide content of the solids trapped in the sand filter will affect the selection of the sand filter disposal pathway. The Pacific Northwest National Laboratory (PNNL) was contracted by the K Basin Operations & Plateau Remediation Project (operations contractor CH2M Hill) to analyze the radionuclide content of the solids collected from the backwash of the K West Basin sand filter. The radionuclide composition in the sand filter backwash solids will be used by CH2M Hill to determine if the sand filter media and retained sludge solids will be designated as transuranic waste for disposal purposes or can be processed through less expensive means. On October 19, 2015, K Basin Operations & Plateau Remediation Project staff backwashed the sand filter into the North Load-Out Pit (NLOP) and immediately collected sample slurry from a sampling tube positioned 24 in. above the NLOP floor. The 764 g sand filter backwash slurry sample, KW-105 SFBW-001, was submitted to PNNL for analysis on October 20, 2015. Solids from the slurry sample were consolidated into two samples (i.e., a primary and a duplicate sample) by centrifuging and measured for mass (0.82 g combined – wet centrifuged solids basis) and volume (0.80 mL combined). The solids were a dark brown/orange color, consistent with iron oxide/hydroxide. The solids were dried; the combined dry solids mass was 0.1113 g, corresponding to 0.0146 weight percent (wt%) solids in the original submitted sample slurry. The solids were acid-digested using nitric and hydrochloric acids. Insoluble solids developed upon dilution with 0.5 M HNO 3 , corresponding to an average 6.5 wt% of the initial dry solids content. The acid digestate and insoluble solids were analyzed separately by gamma spectrometry. Nominally, 7.7% of the 60 Co was present in the insoluble solids; less than 1% of other gamma-emitters (i.e., 137 Cs, 154/155 Eu, and 241 Am) were present in the insoluble solids. Aliquots of the acid digestate were analyzed directly using gamma energy analysis (GEA) and after separations for 238 Pu, 239+240 Pu, 237 Np, and 241 Am radioisotopes using alpha energy analysis (AEA). The 90 Sr was measured by liquid scintillation counting (LSC) on the Sr-separated fraction. The plutonium isotopic distribution of the acid digestate was analyzed following Pu separations by thermal ionization mass spectrometry (TIMS). A table summarizes the results for the primary and duplicate samples. The 239+240 Pu concentration (µCi/g dry) relative to 90 Sr and to 137 Cs concentrations (µCi/g dry) was examined. The K West Basin sludge has a 239+240 Pu/ 90 Sr ranging from 0.1 to 1.2 and the 239+240 Pu/ 137 Cs ratio ranging from 0.10 to 0.47. In contrast, the sand filter backwash solids 239+240 Pu/ 90 Sr ratio was 10.6 and the 239+240 Pu/ 137 Cs ratio was 2.0. The ratio differences indicate a relative enhancement of the Pu concentration in the sand filter solids relative to the 137 Cs and 90 Sr sludge concentrations currently in the K West Basin. A dose-to-curie radioisotope evaluation of the sand filter waste form may need to consider this dissimilarity.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ADAPTIVE OPTICS IMAGING OF VY CANIS MAJORIS AT 2-5 μm WITH LBT/LMIRCam

We present adaptive optics images of the extreme red supergiant VY Canis Majoris in the K{sub s} , L', and M bands (2.15-4.8 μm) made with LMIRCam on the Large Binocular Telescope. The peculiar ''Southwest Clump'' previously imaged from 1 to 2.2 μm appears prominently in all three filters. We find its brightness is due almost entirely to scattering, with the contribution of thermal emission limited to at most 25%. We model its brightness as optically thick scattering from silicate dust grains using typical size distributions. We find a lower limit mass for this single feature of 5 × 10{sup –3} M {sub ☉} to 2.5 × 10{sup –2} M {sub ☉} depending on the assumed gas-to-dust ratio. The presence of the Clump as a distinct feature with no apparent counterpart on the other side of the star is suggestive of an ejection event from a localized region of the star and is consistent with VY CMa's history of asymmetric high-mass-loss events.

79 ASTRONOMY AND ASTROPHYSICS↗

Characteristics of flattening filter free beams at low monitor unit settings

Purpose: Newer linear accelerators (linacs) have been equipped to deliver flattening filter free (FFF) beams. When FFF beams are used for step-and-shoot intensity-modulated radiotherapy (IMRT), the stability of delivery of small numbers of monitor units (MU) is important. The authors developed automatic measurement techniques to evaluate the stability of the dose profile, dose linearity, and consistency. Here, the authors report the performance of the Artiste™ accelerator (Siemens, Erlangen, Germany) in delivering low-MU FFF beams.Methods: A 6 MV flattened beam (6X) with 300 MU/min dose rate and FFF beams of 7 (7XU) and 11 MV (11XU), each with a 500 MU/min dose rate, were measured at 1, 2, 3, 5, 8, 10, and 20 MU settings. For the 2000 MU/min dose rate, the 7 (7XUH) and 11 MV (11XUH) beams were set at 10, 15, 20, 25, and 30 MU because of the limits of the minimum MU settings. Beams with 20 × 20 and 10 × 10 cm{sup 2} field sizes were alternately measured ten times in intensity modulated (IM) mode, with which Siemens linacs regulate beam delivery for step-and-shoot IMRT. The in- and crossplane beam profiles were measured using a Profiler™ Model 1170 (Sun Nuclear Corporation, Melbourne, FL) in multiframe mode. The frames of 20 × 20 cm{sup 2} beams were identified at the off-axis profile. The 6X beam profile was normalized at the central axis. The 7 and 11 MV FFF beam profiles were rescaled to set the dose at the central axis at 145% and 170%, respectively. Point doses were also measured using a Farmer-type ionization chamber and water-equivalent solid phantom to evaluate the linearity and consistency of low-MU beam delivery. The values displayed on the electrometer were recognized with a USB-type camera and read with open-source optical character recognition software.Results: The symmetry measurements of the 6X, 7XU, and 11XU beam profiles were better than 2% for beams ≥2 MU and improved with increasing MU. The variations in flatness of FFF beams ≥2 MU were ±5%. The standard deviation of the symmetry and flatness also decreased with increasing MU. The linearity of the 6X beam was ±1% and ±2% for the beams of ≥5 and ≥3 MU, respectively. The 7XU and 11XU beams of ≥2 MU showed linearity with ±2% except the 7XU beam of 8 MU (+2.9%). The profiles of the FFF beams with 2000 and 500 MU/min dose rate were similar.Conclusions: The characteristics of low-MU beams delivered in IM mode were evaluated using an automatic measurement system developed in this study. The authors demonstrated that the profiles of FFF beams of the Artiste™ linac were highly stable, even at low MU. The linearity of dose output was also stable for beams ≥2 MU.

61 RADIATION PROTECTION AND DOSIMETRY↗

Predictions for the Detectability of Milky Way Satellite Galaxies and Outer-Halo Star Clusters with the Vera C. Rubin Observatory

We predict the sensitivity of the Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) to faint, resolved Milky Way satellite galaxies and outer-halo star clusters. We characterize the expected sensitivity using simulated LSST data from the LSST Dark Energy Science Collaboration (DESC) Data Challenge 2 (DC2) accessed and analyzed with the Rubin Science Platform as part of the Rubin Early Science Program. We simulate resolved stellar populations of Milky Way satellite galaxies and outer-halo star clusters over a wide range of sizes, luminosities, and heliocentric distances, which are broadly consistent with expectations for the Milky Way satellite system. We inject simulated stars into the DC2 catalog with realistic photometric uncertainties and star/galaxy separation derived from the DC2 data itself. We assess the probability that each simulated system would be detected by LSST using a conventional isochrone matched-filter technique. We find that assuming perfect star/galaxy separation enables the detection of resolved stellar systems with $M_V$ = 0 mag and $r_{1/2}$ = 10 pc with >50% efficiency out to a heliocentric distance of ~250 kpc. Similar detection efficiency is possible with a simple star/galaxy separation criterion based on measured quantities, although the false positive rate is higher due to leakage of background galaxies into the stellar sample. When assuming perfect star/galaxy classification and a model for the galaxy-halo connection fit to current data, we predict that 89 +/- 20 Milky Way satellite galaxies will be detectable with a simple matched-filter algorithm applied to the LSST wide-fast-deep data set. Different assumptions about the performance of star/galaxy classification efficiency can decrease this estimate by ~7%-25%, which emphasizes the importance of high-quality star/galaxy separation for studies of the Milky Way satellite population with LSST.

79 ASTRONOMY AND ASTROPHYSICS↗

Status of NIO1 construction

The NIO1 (Negative Ion Optimization phase 1) project consists of a multiaperture negative ion source mounted on a 60 kV accelerating column; up to 9 beamlets (15 mA H{sup -} each one) arranged in 3x3 matrix with 14 mm spacing can be extracted. The moderate size and the modular concept make some relative rotation of the source magnetic filter and the electrodes possible, so that the effect of crossed and aligned field can be easily compared. Other goals of source experimental program are emittance (and beam profile) measurement at several distances (for simulation code validation), testing of diagnostic components and of radiofrequency coupling. A full set of construction drawing was completed; also the Fast Emittance Scanner (FES) and its vacuum chambers were built (four mounting positions are reserved to FES). Some low power rf matching boxes were developed for a test plasma, approximately half the source size. A cesium oven compatible with NIO1 is being also developed; by using some industrial standard 100 W heaters (with a proper driver) a careful control of temperature is planned.

43 PARTICLE ACCELERATORS↗

Mode rotation control in a tokamak with a feedback-driven biased electrode

Rotation of the plasma and MHD modes in tokamaks has been shown to stabilize resistive wall and tearing modes as well as improve confinement through suppression of edge turbulence. In this work, we control mode rotation with a biased electrode inserted into the plasma of the High Beta Tokamak-Extended Pulse’s facility in conjunction with its active GPU (Graphical Processing Unit) feedback system. We first characterize a negative linear relationship between the electrode voltage and mode rotation. Using this relationship, we design, simulate, and implement a proof-of-concept, GPU-based active-control system, which shows consistent success in controlling mode rotation in both feedforward and feedback operation. Controllability is limited by operating conditions, the electrode’s voltage range, and by the electrode’s proximity to the vessel’s walls. The final control system has a 15 μs cycle time, but the addition of various signal filters results in a full cycle latency of 200 μs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗