Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlation analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

An adaptable pentaloop defines a robust neomycin-B RNA aptamer with conditional ligand-bound structures

Aptamers can be highly specific for their targets, which implies precise molecular recognition between aptamer and target. However, as small polymers, their structures are more subject to environmental conditions than the more constrained longer RNAs such as those that constitute the ribosome. To understand the balance between structural and environmental factors in establishing ligand specificity of aptamers, we examined the RNA aptamer (NEO1A) previously reported as specific for neomycin-B. We show that NEO1A can recognize other aminoglycosides with similar affinities as for neomycin-B and its aminoglycoside specificity is strongly influenced by ionic strength and buffer composition. NMR and 2-aminopurine (2AP) fluorescence studies of the aptamer identified a flexible pentaloop and a stable binding pocket. Consistent with a well structured binding pocket, docking analysis results correlated with experimental measures of the binding energy for most ligands. Steady state fluorescence studies of 2AP-substituted aptamers confirmed that A16 moves to a more solvent accessible position upon ligand binding while A14 moves to a less solvent accessible position, which is most likely a base stack. Analysis of binding affinities of NEO1A sequence variants showed that the base in position 16 interacts differently with each ligand and the interaction is a function of the buffer constituents. Our results show that the pentaloop provides NEO1A with the ability to adapt to external influences on its structure, with the critical base at position 16 adjusting to incorporate each ligand into a stable pocket by hydrophobic interactions and/or hydrogen bonds depending on the ligand and the ionic environment.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization and Scaling of Forced Convective Swirl in Sinusoidal Wavy-Plate-Fin Cores of Compact Heat Exchangers

The characterization and scaling of the thermal-hydraulic performance in wavy plate-fin compact heat exchanger cores, based on the understanding of the physical phenomena and heat transfer enhancement mechanism is delineated. Experimental data are presented for forced convection in air (Pr = 0.71) with flow rates in the range 50 ≤ Re ≤ 4000. A variety of wavy-fin cores that span viable applications, with geometrical attributes described by the cross section aspect ratio α (ratio of fin spacing to height), fin corrugation aspect ratio γ (ratio of 2× corrugation amplitude to wave pitch), and fin spacing ratio ζ (ratio of fin spacing to wave pitch), are considered. To characterize and correlate the vortex-flow mixing in interfin spaces, a Swirl number Sw is introduced from the balance of viscous, inertial and centrifugal forces. It is shown that the laminar, transitional and turbulent flow regimes can be explicitly identified by this Swirl number. Based on the experimental results and extended analysis, new correlations for Fanning friction factor f and Colburn factor j are developed with Sw, α, γ, and ζ as scaling parameters. Requisite expressions are devised by a superposition of both enhancement components due to the corrugated surface area enlargement and induced swirl flow field, and they are combined to cover the laminar, transitional and turbulent regimes by the method of asymptotic matching. The resulting generalized correlations are further shown to predict all available experimental data for f and j factors to within ±20% and ±15%, respectively.

42 ENGINEERING↗

SU-C-BRF-07: A Pattern Fusion Algorithm for Multi-Step Ahead Prediction of Surrogate Motion

Purpose: To assure that tumor motion is within the radiation field during high-dose and high-precision radiosurgery, real-time imaging and surrogate monitoring are employed. These methods are useful in providing real-time tumor/surrogate motion but no future information is available. In order to anticipate future tumor/surrogate motion and track target location precisely, an algorithm is developed and investigated for estimating surrogate motion multiple-steps ahead. Methods: The study utilized a one-dimensional surrogate motion signal divided into three components: (a) training component containing the primary data including the first frame to the beginning of the input subsequence; (b) input subsequence component of the surrogate signal used as input to the prediction algorithm: (c) output subsequence component is the remaining signal used as the known output of the prediction algorithm for validation. The prediction algorithm consists of three major steps: (1) extracting subsequences from training component which best-match the input subsequence according to given criterion; (2) calculating weighting factors from these best-matched subsequence; (3) collecting the proceeding parts of the subsequences and combining them together with assigned weighting factors to form output. The prediction algorithm was examined for several patients, and its performance is assessed based on the correlation between prediction and known output. Results: Respiratory motion data was collected for 20 patients using the RPM system. The output subsequence is the last 50 samples (∼2 seconds) of a surrogate signal, and the input subsequence was 100 (∼3 seconds) frames prior to the output subsequence. Based on the analysis of correlation coefficient between predicted and known output subsequence, the average correlation is 0.9644±0.0394 and 0.9789±0.0239 for equal-weighting and relative-weighting strategies, respectively. Conclusion: Preliminary results indicate that the prediction algorithm is effective in estimating surrogate motion multiple-steps in advance. Relative-weighting method shows better prediction accuracy than equal-weighting method. More parameters of this algorithm are under investigation.

60 APPLIED LIFE SCIENCES↗

Radiation-Induced Liver Damage: Correlation of Histopathology with Hepatobiliary Magnetic Resonance Imaging, a Feasibility Study

PurposeRadiotherapy of liver malignancies shows promising results (radioembolization, stereotactic irradiation, interstitial brachytherapy). Regardless of the route of application, a certain amount of nontumorous liver parenchyma will be collaterally damaged by radiation. The functional reserve may be significantly reduced with an impact on further treatment planning. Monitoring of radiation-induced liver damage by imaging is neither established nor validated. We performed an analysis to correlate the histopathological presence of radiation-induced liver damage with functional magnetic resonance imaging (MRI) utilizing hepatobiliary contrast media (Gd-BOPTA).MethodsPatients undergoing local high-dose-rate brachytherapy for whom a follow-up hepatobiliary MRI within 120 days after radiotherapy as well as an evaluable liver biopsy from radiation-exposed liver tissue within 7 days before MRI were retrospectively identified. Planning computed tomography (CT)/dosimetry was merged to the CT-documentation of the liver biopsy and to the MRI. Presence/absence of radiation-induced liver damage (histopathology) and Gd-BOPTA uptake (MRI) as well as the dose applied during brachytherapy at the site of tissue sampling was determined.ResultsFourteen biopsies from eight patients were evaluated. In all cases with histopathological evidence of radiation-induced liver damage (n = 11), no uptake of Gd-BOPTA was seen. In the remaining three, cases no radiation-induced liver damage but Gd-BOPTA uptake was seen. Presence of radiation-induced liver damage and absence of Gd-BOPTA uptake was correlated with a former high-dose exposition.ConclusionsAbsence of hepatobiliary MRI contrast media uptake in radiation-exposed liver parenchyma may indicate radiation-induced liver damage. Confirmatory studies are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SDSS-II SUPERNOVA SURVEY: AN ANALYSIS OF THE LARGEST SAMPLE OF TYPE IA SUPERNOVAE AND CORRELATIONS WITH HOST-GALAXY SPECTRAL PROPERTIES

Using the largest single-survey sample of Type Ia supernovae (SNe Ia) to date, we study the relationship between properties of SNe Ia and those of their host galaxies, focusing primarily on correlations with Hubble residuals (HRs). Our sample consists of 345 photometrically classified or spectroscopically confirmed SNe Ia discovered as part of the SDSS-II Supernova Survey (SDSS-SNS). This analysis utilizes host-galaxy spectroscopy obtained during the SDSS-I/II spectroscopic survey and from an ancillary program on the SDSS-III Baryon Oscillation Spectroscopic Survey that obtained spectra for nearly all host galaxies of SDSS-II SN candidates. In addition, we use photometric host-galaxy properties from the SDSS-SNS data release such as host stellar mass and star formation rate. We confirm the well-known relation between HR and host-galaxy mass and find a 3.6 σ significance of a nonzero linear slope. We also recover correlations between HR and host-galaxy gas-phase metallicity and specific star formation rate as they are reported in the literature. With our large data set, we examine correlations between HR and multiple host-galaxy properties simultaneously and find no evidence of a significant correlation. We also independently analyze our spectroscopically confirmed and photometrically classified SNe Ia and comment on the significance of similar combined data sets for future surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Advanced data science toolkit for non-data scientists – A user guide

Emerging modern data analytics attracts much attention in materials research and shows great potential for enabling data-driven design. Data populated from the high-throughput CALPHAD approach enables researchers to better understand underlying mechanisms and to facilitate novel hypotheses generation, but the increasing volume of data makes the analysis extremely challenging. Here in this paper, we introduce an easy-to-use, versatile, and open-source data analytics frontend, ASCENDS (Advanced data SCiENce toolkit for Non-Data Scientists), designed with the intent of accelerating data-driven materials research and development. The toolkit is also of value beyond materials science as it can analyze the correlation between input features and target values, train machine learning models, and make predictions from the trained surrogate models of any scientific dataset. Various algorithms implemented in ASCENDS allow users performing quantified correlation analyses and supervised machine learning to explore any datasets of interest without extensive computing and data science background. The detailed usage of ASCENDS is introduced with an example of experimental high-temperature alloy data.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

The Analysis of Dimensionality Reduction Techniques in Cryptographic Object Code Classification

This paper compares the application of three different dimension reduction techniques to the problem of locating cryptography in compiled object code. A simple classi?er is used to compare dimension reduction via sorted covariance, principal component analysis, and correlation-based feature subset selection. The analysis concentrates on the classi?cation accuracy as the number of dimensions is increased.

97 MATHEMATICS AND COMPUTING↗

Practical Application of Parallel Coordinates for Climate Model Analysis

The determination of relationships between climate variables and the identification of the most significant associations between them in various geographic regions is an important aspect of climate model evaluation. The EDEN visual analytics toolkit has been developed to aid such analysis by facilitating the assessment of multiple variables with respect to the amount of variability that can be attributed to specific other variables. EDEN harnesses the parallel coordinates visualization technique and is augmented with graphical indicators of key descriptive statistics. A case study is presented in which the focus on the Harvard Forest site (42.5378N Lat, 72.1715W Lon) and the Community Land Model Version 4 (CLM4) is evaluated. It is shown that model variables such as land water runoff are more sensitive to a particular set of environmental variables than a suite of other inputs in the 88 variable analysis conducted. The approach presented here allows climate-domain scientists to focus on the most important variables in the model evaluations.

54 ENVIRONMENTAL SCIENCES↗

A DEEP 1.2 mm MAP OF THE LOCKMAN HOLE NORTH FIELD

We present deep 1.2 mm continuum mapping of a 566 arcmin{sup 2} area within the Lockman Hole North (LHN) field, previously a target of the Spitzer Wide-Area Infrared Extragalactic survey and extremely deep 20 cm mapping with the Very Large Array, which we have obtained using the Max-Planck millimeter bolometer (MAMBO) array on the IRAM 30 m telescope. After filtering, our full map has an rms sensitivity ranging from 0.45 to 1.5 mJy beam{sup -1}, with an average of 0.75 mJy beam{sup -1}. Using the pixel flux distribution (PFD) in a map made from our best data, we determine the shape, normalization, and approximate flux density cutoff for 1.2 mm number counts well below our nominal sensitivity and confusion limits. After validating our full data set through comparison with this map, we successfully detect 41 1.2 mm sources with signal-to-noise ratio (S/N) > 4.0 and S{sub 1.2{sub mm}} {approx_equal} 2-5 mJy. We use the most significant of these detections to directly determine the integral number counts down to 1.8 mJy, which are consistent with the results of the PFD analysis. Ninety-three percent of our 41 individual detections have 20 cm counterparts, 49% have Spitzer/MIPS 24 {mu}m counterparts, and one may have a significant Chandra X-ray counterpart. We resolve {approx_equal} 3% of the cosmic infrared background (CIB) at 1.2 mm into significant detections and directly estimate a 0.05 mJy faint-end cutoff for the counts that is consistent with the full intensity of the 1.2 mm CIB. The median redshift of our 17 detections with spectroscopic or robust photometric redshifts is z{sub median} = 2.3, and rises to z{sub median} = 2.9 when we include redshifts estimated from the radio/far-infrared spectral index. By using a nearest neighbor and angular correlation function analysis, we find evidence that our S/N > 4.0 detections are clustered at the 95% confidence level.

79 ASTRONOMY AND ASTROPHYSICS↗

Physics-informed machine learning exploration of Na storage mechanisms in disordered carbon

Sodium-ion batteries are a cost-effective, sustainable alternative to lithium-ion systems for large-scale energy storage. However, optimizing sodium storage in carbon-based anodes with microstructural complexity and atomic disorder remains a major challenge. The intrinsic inhomogeneity of these materials produces diverse local environments, making it difficult for conventional methods to predict and control ion dynamics. Hard carbon (HC) anodes, composed of ranges of ordered-to-disordered graphitic and amorphous nanodomains, offer tunable ion storage and rate capacity, yet rationale design remains a challenge due to poorly understood correlation between local atomic feature and ion transport mechanism. Here, to address this challenge, we introduce a data-driven framework that integrates validated machine-learned interatomic potentials, large-scale molecular dynamics simulations, and machine learning to elucidate sodium transport mechanisms as a function of carbon and sodium loading densities. By computing per-ion structural descriptors and applying unsupervised learning, we identify distinct diffusion modes governed by microscopic features. Supervised analysis and correlation mapping then establish quantitative links between these transport regimes and processing variables such as bulk carbon density and sodium content. This physics-informed approach establishes quantitative structure–transport relationships and offers actionable design principles for engineering high-performance HC anodes.

Data-driven framework↗

PROBING PRIMORDIAL MAGNETIC FIELDS USING Ly{alpha} CLOUDS

From previous studies of the effect of primordial magnetic fields on early structure formation, we know that the presence of primordial magnetic fields during early structure formation could induce more perturbations at small scales (at present 1-10 h {sup -1} Mpc) as compared to the usual {Lambda}CDM theory. Matter power spectra over these scales are effectively probed by cosmological observables such as shear correlation and Ly{alpha} clouds. In this paper we discuss the implications of primordial magnetic fields on the distribution of Ly{alpha} clouds. We simulate the line-of-sight density fluctuation including the contribution coming from the primordial magnetic fields. We compute the evolution of Ly{alpha} opacity for this case and compare our theoretical estimates of Ly{alpha} opacity with the existing data to constrain the parameters of the primordial magnetic fields. We also discuss the case when the two density fields are correlated. Our analysis yields an upper bound of roughly 0.3-0.6 nG on the magnetic field strength for a range of nearly scale-invariant models, corresponding to a magnetic field power spectrum index n {approx_equal} -3.

79 ASTRONOMY AND ASTROPHYSICS↗

Correlative electron and ion beam analysis of the electrochemical performances of LiV 3 O 8 cathode films as a function of microstructures

Degradation mechanisms in LiV 3 O 8 cathode films (~500 nm) with different initial microstructures i.e., globular nanocrystals in amorphous matrix and needle-like nanocrystals, synthesized by annealing the cathodes at 150 °C and 300 °C for 6 h are studied by Transmission Electron Microscopy (TEM) and Auger Electron Spectroscopy (AES). In addition, a unique in-situ combination of TEM and Secondary Ion Mass Spectrometry (SIMS) imaging techniques, namely Parallel Ion and Electron beam Spectrometry (PIES) is carried out to measure the 3D distribution of V and Li with nanoscale resolution. These characterization studies focus on correlating the pre- and post-cycling microstructure to observed electrochemical performance. The LiV 3 O 8 cathode film with needle-like nanocrystals (300 °C) shows a higher initial capacity but it degrades rapidly compared to the film with globular nanocrystals embedded in amorphous matrix (150 °C). We observed that LiV 3 O 8 films with needle-like nanocrystals are more susceptible to cathode decohesion and vanadium dissolution than the films with globular nanocrystals embedded in amorphous matrix, explaining the differences in their electrochemical performance. The findings from this study have relevance to the development of thin film electrode microstructures for high capacity and cyclic stability.

25 ENERGY STORAGE↗

Development and evaluation of a list mode neutron coincidence collar for spatial response measurements of fresh fuel assemblies

A traditional safeguards neutron coincidence counting system, the Neutron Coincidence Collar, has been modified to incorporate individual preamplifiers on each of its 18 3He tubes in active interrogation mode. When used with list mode data acquisition (LMDA) and analysis, a signal from each 3He tube can be recorded and analyzed to allow a spatial response measurement to be performed on an item based on count rate and 3He tube location within the system. The ultimate goal of this project is to demonstrate the capabilities of a list mode response matrix for the nondestructive assay of fresh nuclear fuel assemblies. To enable partial defect detection of fuel pin locations and absences within an assembly, the project aims to extend well-established correlated neutron analysis techniques on a preexisting Neutron Coincidence Collar by extracting a greater number of useful signatures from the system than are currently generated. LMDA, combined with the addition of multiple preamplifiers, facilitates this capability by increasing the number of simultaneous signals that can be measured; this allows an in-depth analysis of neutron coincidence events to determine a fissioning item’s location based on the measured doubles count rate in various channel logic coincidence combinations. All of this can be done from a single measurement pulse train in offline analysis, which is the major benefit provided by LMDA. Through various stages of development and testing, a Mirion Technologies model JCC-71 Neutron Coincidence Collar has been successfully retrofit with modern electronics designed in-house at Oak Ridge National Laboratory, matching preexisting JAB-01 electronics performance, while maintaining the original system footprint. This paper presents these various stages of development and experimental evaluation of the proof of concept system.

Moore, Angela S.↗

How do mirror charge radii constrain density dependence of the symmetry energy?

It has recently been suggested that differences in the charge radii of mirror nuclei (Δ$R^{mirr}_{ch}$) are strongly correlated with the neutron-skin thickness ($R_{skin}$) of neutron-rich nuclei and with the slope of the symmetry energy ($L$). To test this assumption, we present ab initio calculations of $R_{skin}$ in 48 Ca and 208 Pb, Δ$R^{mirr}_{ch}$ in 36 Ca$-$ 36 S, 38 Ca$-$ 38 Ar, 41 Sc$-$ 41 Ca, 48 Ni$-$ 48 Ca, 52 Ni$-$ 52 Cr, and 54 Ni$-$ 54 Fe mirror pairs, and $L$. Employing the recently developed 34 chiral interaction samples, identified by the history matching approach, we conduct rigorous statistical analysis of correlations among Δ$R^{mirr}_{ch}$, $R_{skin}$ and $L$, accounting for quantified uncertainties from low-energy constants of chiral interaction, chiral effective field theory truncation and many-body method approximation. The ab initio results reveal an appreciable Δ$R^{mirr}_{ch}$ $-$ $L$ correlation in $fp$-shell mirror pairs. However, contrary to previous studies, the present calculation finds that the studied $sd$-shell mirror pairs do not exhibit any Δ$R^{mirr}_{ch}$ $-$ $L$ correlation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Origin of parameter degeneracy and molecular shape relationships in geometric-flow calculations of solvation free energies

Implicit solvent models are important tools for calculating solvation free energies for chemical and biophysical studies since they require fewer computational resources but can achieve accuracy comparable to that of explicit-solvent models. In past papers, geometric flow-based solvation models have been established for solvation analysis of small and large compounds. In the present work, the use of realistic experiment-based parameter choices for the geometric flow models is studied. We find that the experimental parameters of solvent internal pressure p = 172 MPa and surface tension γ = 72 mN/m produce solvation free energies within 1 RT of the global minimum root-mean-squared deviation from experimental data over the expanded set. Our results demonstrate that experimental values can be used for geometric flow solvent model parameters, thus eliminating the need for additional parameterization. We also examine the correlations between optimal values of p and γ which are strongly anti-correlated. Geometric analysis of the small molecule test set shows that these results are inter-connected with an approximately linear relationship between area and volume in the range of molecular sizes spanned by the data set. In spite of this considerable degeneracy between the surface tension and pressure terms in the model, both terms are important for the broader applicability of the model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Early Outcomes From Three Prospective Trials of Image-Guided Proton Therapy for Prostate Cancer

Purpose: To report early outcomes with image-guided proton therapy for prostate cancer. Methods and Materials: We accrued 211 prostate cancer patients on prospective Institutional Review Board-approved trials of 78 cobalt gray equivalent (CGE) in 39 fractions for low-risk disease, dose escalation from 78 to 82 CGE for intermediate-risk disease, and 78 CGE with concomitant docetaxel followed by androgen deprivation for high-risk disease. Minimum follow-up was 2 years. Results: One intermediate-risk patient and 2 high-risk patients had disease progression. Pretreatment genitourinary (GU) symptom management was required in 38% of patients. A cumulative 88 (42%) patients required posttreatment GU symptom management. Four transient Grade 3 GU toxicities occurred, all among patients requiring pretreatment GU symptom management. Multivariate analysis showed correlation between posttreatment GU 2+ symptoms and pretreatment GU symptom management (p < 0.0001) and age (p = 0.0048). Only 1 Grade 3+ gastrointestinal (GI) symptom occurred. The prevalence of Grade 2+ GI symptoms was 0 (0%), 10 (5%), 12 (6%), and 8 (4%) at 6, 12, 18, and 24 months, with a cumulative incidence of 20 (10%) patients at 2 years after proton therapy. Univariate and multivariate analyses showed significant correlation between Grade 2+ rectal bleeding and proctitis and the percentage of rectal wall (rectum) receiving doses ranging from 40 CGE (10 CGE) to 80 CGE. Conclusions: Early outcomes with image-guided proton therapy suggest high efficacy and minimal toxicity with only 1.9% Grade 3 GU symptoms and <0.5% Grade 3 GI toxicities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Model of defect reactions and the influence of clustering in pulse-neutron-irradiated Si

Transient reactions among irradiation defects, dopants, impurities, and carriers in pulse-neutron-irradiated Si were modeled taking into account the clustering of the primal defects in recoil cascades. Continuum equations describing the diffusion, field drift, and reactions of relevant species were numerically solved for a submicrometer spherical volume, within which the starting radial distributions of defects could be varied in accord with the degree of clustering. The radial profiles corresponding to neutron irradiation were chosen through pair-correlation-function analysis of vacancy and interstitial distributions obtained from the binary-collision code MARLOWE, using a spectrum of primary recoil energies computed for a fast-burst fission reactor. Model predictions of transient behavior were compared with a variety of experimental results from irradiated bulk Si, solar cells, and bipolar-junction transistors. The influence of defect clustering during neutron bombardment was further distinguished through contrast with electron irradiation, where the primal point defects are more uniformly dispersed.

36 MATERIALS SCIENCE↗