Search NASA⌕ Search

SEARCH · Search NASA

Results for “defect imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

SU-C-304-05: Use of Local Noise Power Spectrum and Wavelets in Comprehensive EPID Quality Assurance

Purpose: As EPIDs are increasingly used for IMRT QA and real-time treatment verification, comprehensive quality assurance (QA) of EPIDs becomes critical. Current QA with phantoms such as the Las Vegas and PIPSpro™ can fail in the early detection of EPID artifacts. Beyond image quality assessment, we propose a quantitative methodology using local noise power spectrum (NPS) to characterize image noise and wavelet transform to identify bad pixels and inter-subpanel flat-fielding artifacts. Methods: A total of 93 image sets including bar-pattern images and open exposure images were collected from four iViewGT a-Si EPID systems over three years. Quantitative metrics such as modulation transform function (MTF), NPS and detective quantum efficiency (DQE) were computed for each image set. Local 2D NPS was calculated for each subpanel. A 1D NPS was obtained by radial averaging the 2D NPS and fitted to a power-law function. R-square and slope of the linear regression analysis were used for panel performance assessment. Haar wavelet transformation was employed to identify pixel defects and non-uniform gain correction across subpanels. Results: Overall image quality was assessed with DQE based on empirically derived area under curve (AUC) thresholds. Using linear regression analysis of 1D NPS, panels with acceptable flat fielding were indicated by r-square between 0.8 and 1, and slopes of −0.4 to −0.7. However, for panels requiring flat fielding recalibration, r-square values less than 0.8 and slopes from +0.2 to −0.4 were observed. The wavelet transform successfully identified pixel defects and inter-subpanel flat fielding artifacts. Standard QA with the Las Vegas and PIPSpro phantoms failed to detect these artifacts. Conclusion: The proposed QA methodology is promising for the early detection of imaging and dosimetric artifacts of EPIDs. Local NPS can accurately characterize the noise level within each subpanel, while the wavelet transforms can detect bad pixels and inter-subpanel flat fielding artifacts.

60 APPLIED LIFE SCIENCES↗

Three-dimensional imaging of vortex structure in a ferroelectric nanoparticle driven by an electric field

Topological defects of spontaneous polarization are extensively studied as templates for unique physical phenomena and in the design of reconfigurable electronic devices. Experimental investigations of the complex topologies of polarization have been limited to surface phenomena, which has restricted the probing of the dynamic volumetric domain morphology in operando. Here, we utilize Bragg coherent diffractive imaging of a single BaTiO 3 nanoparticle in a composite polymer/ferroelectric capacitor to study the behavior of a three-dimensional vortex formed due to competing interactions involving ferroelectric domains. Our investigation of the structural phase transitions under the influence of an external electric field shows a mobile vortex core exhibiting a reversible hysteretic transformation path. We also study the toroidal moment of the vortex under the action of the field. Our results open avenues for the study of the structure and evolution of polar vortices and other topological structures in operando in functional materials under cross field configurations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The application of cinematic rendering to CT evaluation of upper tract urothelial tumors: principles and practice

Upper tract urothelial carcinoma (UTUC) is a relatively uncommon but aggressive genitourinary malignancy for which multi-phase contrast-enhanced computed tomography (CT) plays an important role in evaluation and staging. 3D imaging with maximum intensity projection (MIP) and volume-rendered (VR) images has been described as a useful means of evaluating UTUC. In this study, we describe the technique of a novel 3D methodology known as cinematic rendering (CR) and provide clinical examples of UTUC visualized with CR. CR utilizes a complex universal lighting model in order to create photorealistic images with improved detail and depth in comparison to MIP or VR images. In the case of UTUC, CR can be used in different contrast phases to show abnormally thickened and enhancing urothelium or filling defects in the renal collecting system or ureters in the excretory phase. CR images can also be manipulated in order to generate translucent views of the upper urinary tract in order to add conspicuity to intraluminal findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An algorithm to unveil the inner structure of objects concealed by beam divergence in radiographic image acquisition systems

Two main parameters rule the performance of an Image Acquisition System, namely, spatial resolution and contrast. For radiographic systems using cone beam arrangements, the farther the source, the better the resolution, but the contrast would diminish due to the lower statistics. A closer source would yield a higher contrast but it would no longer reproduce the attenuation map of the object, as the incoming beam flux would be reduced by unequal large divergences and attenuation factors. This work proposes a procedure to correct these effects when the object is comprised of a hull - or encased in it - possessing a shape capable to be described in analytical geometry terms. Such a description allows the construction of a matrix containing the attenuation factors undergone by the beam from the source until its final destination at each coordinate on the 2D detector. Each matrix element incorporates the attenuation suffered by the beam after its travel through the hull wall, as well as its reduction due to the square of distance to the source and the angle it hits the detector surface. When the pixel intensities of the original image are corrected by these factors, the image contrast, reduced by the overall attenuation in the exposure phase, are recovered, allowing one to see details otherwise concealed due to the low contrast. In order to verify the soundness of this approach, synthetic images of objects of different shapes, such as plates and tubes, incorporating defects and statistical fluctuation, have been generated, recorded for further comparison and afterwards processed to improve their contrast. The developed algorithm which, generates processes and plots the images has been written in Fortran 90 language. As the resulting final images exhibit the expected improvements, it therefore seemed worthwhile to carry out further tests with actual experimental radiographies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Realization of defect-free epitaxial core-shell GaAs/AlGaAs nanowire heterostructures

We report the controlled growth of vertically aligned GaAs/AlGaAs core-shell nanowires. By optimizing the shell deposition temperature and catalyst density we maintain high temperature stability and achieve defect-free epitaxial AlGaAs shell deposition with high aluminum incorporation. Energy dispersive x-ray analysis determines the shell composition to be Al{sub 0.9}Ga{sub 0.1}As and measures the uniformity of the shell thickness. Lattice-resolved high-angle annular dark-field scanning transmission electron microscopy images confirm the core-shell interface to be defect-free, epitaxial, and atomically sharp. The ability to realize GaAs/AlGaAs core-shell nanowires with precise control over the morphology and composition is essential to the development of nanowire-based high mobility electronics.

36 MATERIALS SCIENCE↗

Atomic-scale electronic inhomogeneity in single-layer iron chalcogenide alloys revealed by machine learning of STM/S data

Chemical pressure from the isovalent substitution of Se by a larger Te atom in the epitaxial film of iron chalcogenide FeSe can effectively tune its superconducting, topological, and magnetic properties. However, such substitution during epitaxial growth inherently leads to defects and structural inhomogeneity, making the determination of alloy composition and atomic sites for the substitutional Te atoms challenging. Here, we utilize machine learning to distinguish between Se and Te atoms in scanning tunneling microscopy images of single-layer FeSe1−xTex on SrTiO3(001) substrates. Defect locations are first identified by analyzing spatial-dependent dI/dV tunneling spectra using the K-means clustering method. After excluding the defect regions, the remaining dI/dV spectra are further analyzed using the singular value decomposition method to determine the Se/Te ratio. Our findings demonstrate an effective and reliable approach for determining alloy composition and atomic-scale electronic inhomogeneity in superconducting single-layer iron chalcogenide films.

Materials Science↗

SMC2021 Where to go in atomic world

'Graphene_CrSi.npy' contains a scanning transmission electron microscopy (STEM) movie from graphene monolayer. The movie is a sequence of atom-resolved images from the same sample region that undergoes chemical and structural transformations due to interaction with electron beam (which is used to perform imaging). 'topo_defects.npy' contains coordinates of some of the objects of interest (topological defects in graphene). It is a dictionary, where keys are frame numbers and values are xy coordinates. These objects are usually localized in relatively small areas of the image and we are interested in identifying them without having to scan an entire grid (which leads to fast degradation of the sample).

36 MATERIALS SCIENCE↗

Performance Validation of Pulsed Thermal Imaging System for In-Service Applications

Additive manufacturing (AM) is an emerging method for cost-efficient fabrication of complex topology nuclear reactor parts from high-strength corrosion resistance alloys, such as stainless steel and Inconel. AM of metallic structures for nuclear energy applications is currently based on laser powder bed fusion (LPBF) process, which has the capability of melting metallic powder and net shaping the structures with relatively high precision. Some of the challenges with using LPBF method for nuclear manufacturing include the possibility of introducing pores into metallic structures. Integrity of AM structures needs to be evaluated nondestructively because material flaws could lead to premature failures in high temperature nuclear reactor environment. Currently, there exist limited capabilities to evaluate actual AM structures non-destructively. Pulsed Thermography Imaging (PTI) provides a capability for non-destructive evaluation (NDE) of subsurface defects in arbitrary size structures. The PTI method is based on recording material surface temperature transients with infrared (IR) camera following thermal pulse delivered on material surface with flash light. The PTI method has advantages for NDE of actual AM structures because the method involves one-sided non-contact measurements and fast processing of large sample areas captured in one image. Following initial qualification of an AM component for deployment in a nuclear reactor, a PTI system can also be used for in-service nondestructive evaluation (NDE) applications. In this report, we describe recent progress in enhancing PTI capabilities in detecting microscopic defects in metallic specimens. SS316 and IN718 specimens were developed with a pattern of subsurface calibrated flat bottom hole (FBH) defects with diameters from 500µm to 200µm. FBH’s were created with EDM (electron discharge machining) drill. PTI imaging data was processed Spatial Temporal Denoised Thermal Source Separation (STDTSS) unsupervised machine learning (ML) algorithm. We show that defects as small as 200µm in SS316 and IN718 can be detected with STDTSS algorithm. To the best of our knowledge, these are the smallest detected defects which are reported in literature.

42 ENGINEERING↗

Noninvasive 3D Visualization of Defects and Crack Propagation in Layered Foam Structures by Phase Contrast Microimaging

Applications of polymeric foams in our modern society continue to grow because of their light weight, high strength, excellent thermal and mechanical insulation, and the ease of engineering. Among others, closed-cell foam has been structurally used for thermally insulating the shuttle external tank. However, internal defects of the foams were difficult to observe non-invasively due to limited sensitivity to the low-density structures possessed by traditional imaging tools such as computed X-ray tomography By combining phase contrast X-ray imaging with pressure loading, we succeeded in precisely mapping intact cellular structure and defects inside the bulk of layered foam and visualizing its subsequent response to the pressure in three-dimensional space. The work demonstrated a powerfir1 approach for yielding insight into underlying problems in lightweight cellular materials otherwise unobtainable.

Hu, Z. W.↗

Imaging dark charge emitters in diamond via carrier-to-photon conversion

The application of color centers in wide-bandgap semiconductors to nanoscale sensing and quantum information processing largely rests on our knowledge of the surrounding crystalline lattice, often obscured by the countless classes of point defects the material can host. Here, we monitor the fluorescence from a negatively charged nitrogen-vacancy (NV – ) center in diamond as we illuminate its vicinity. Cyclic charge state conversion of neighboring point defects sensitive to the excitation beam leads to a position-dependent stream of photo-generated carriers whose capture by the probe NV – leads to a fluorescence change. This “charge-to-photon” conversion scheme allows us to image other individual point defects surrounding the probe NV, including nonfluorescent “single-charge emitters” that would otherwise remain unnoticed. Given the ubiquity of color center photochromism, this strategy may likely find extensions to material systems other than diamond.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Imaging the Hydrogen Absorption Dynamics of Individual Grains in Polycrystalline Palladium Thin Films in 3D

Defects such as dislocations and grain boundaries often control the properties of polycrystalline materials. In nanocrystalline materials, investigating this structure-function relationship while preserving the sample remains challenging because of the short length scales and buried interfaces involved. Here we use Bragg coherent diffractive imaging to investigate the role of structural inhomogeneity on the hydriding phase transformation dynamics of individual Pd grains in polycrystalline films in three-dimensional detail. In contrast to previous reports on single- and polycrystalline nanoparticles, we observe no evidence of a hydrogen-rich surface layer and consequently no size dependence in the hydriding phase transformation pressure over a 125-325 nm size range. We do observe interesting grain boundary dynamics, including reversible rotations of grain lattices while the material remains in the hydrogen-poor phase. The mobility of the grain boundaries, combined with the lack of a hydrogen-rich surface layer, suggests that the grain boundaries are acting as fast diffusion sites for the hydrogen atoms. Such hydrogen-enhanced plasticity in the hydrogen poor phase provides insight into the switch from the size-dependent behavior of single-crystal nanoparticles to the lower transformation pressures of polycrystalline materials and may play a role in hydrogen embrittlement.

Yau, Allison↗

Three-dimensional X-ray diffraction imaging of dislocations in polycrystalline metals under tensile loading

Abstract The nucleation and propagation of dislocations is an ubiquitous process that accompanies the plastic deformation of materials. Consequently, following the first visualization of dislocations over 50 years ago with the advent of the first transmission electron microscopes, significant effort has been invested in tailoring material response through defect engineering and control. To accomplish this more effectively, the ability to identify and characterize defect structure and strain following external stimulus is vital. Here, using X-ray Bragg coherent diffraction imaging, we describe the first direct 3D X-ray imaging of the strain field surrounding a line defect within a grain of free-standing nanocrystalline material following tensile loading. By integrating the observed 3D structure into an atomistic model, we show that the measured strain field corresponds to a screw dislocation.

36 MATERIALS SCIENCE↗

Multi-frame, ultrafast, x-ray microscope for imaging shockwave dynamics

Inertial confinement fusion (ICF) holds increasing promise as a potential source of abundant, clean energy, but has been impeded by defects such as micro-voids in the ablator layer of the fuel capsules. It is critical to understand how these micro-voids interact with the laser-driven shock waves that compress the fuel pellet. At the Matter in Extreme Conditions (MEC) instrument at the Linac Coherent Light Source (LCLS), we utilized an x-ray pulse train with ns separation, an x-ray microscope, and an ultrafast x-ray imaging (UXI) detector to image shock wave interactions with micro-voids. To minimize the high- and low-frequency variations of the captured images, we incorporated principal component analysis (PCA) and image alignment for flat-field correction. After applying these techniques we generated phase and attenuation maps from a 2D hydrodynamic radiation code (xRAGE), which were used to simulate XPCI images that we qualitatively compare with experimental images, providing a one-to-one comparison for benchmarking material performance. Moreover, we implement a transport-of-intensity (TIE) based method to obtain the average projected mass density (areal density) of our experimental images, yielding insight into how defect-bearing ablator materials alter microstructural feature evolution, material compression, and shock wave propagation on ICF-relevant time scales.

47 OTHER INSTRUMENTATION↗

Characterization of radiation damage in 3D printed SiC

The SiC fuel matrix for advanced gas-cooled high temperature reactors as part of the Transformational Challenge Reactor program serves as the fuel particle container structure, a barrier to fission gas release, and a heat transfer medium. Its performance is particularly important because the fuel matrix must demonstrate good structural stability and thermal behaviors. An additive manufacturing methodology combining a binder jet 3D printing process with chemical vapor infiltration (CVI) for the production of SiC was recently developed. In this study, post irradiation examination by transmission electron microscopy shows that defect accumulation within the printed particles is very similar to other forms of high-purity SiC. However, damage accumulation was not directly observed in the CVI matrix because black spot damage and dislocation loops are difficult to image within the nanoscale highly faulted CVI matrix and because interstitial defects may rapidly annihilate at the stacking faults. Therefore, electron energy loss spectroscopy (EELS) analysis was used to analyze defect swelling in both the printed particles and the CVI matrix. The EELS analysis helped reveal that the radiation-induced swelling in the CVI matrix is similar to that of the printed SiC particles. This work shows that 3D printed SiC has behavior that is comparable to SiC processed by other means and that 3D printing could serve as a suitable processing technique for high-purity SiC for nuclear applications.

36 MATERIALS SCIENCE↗

EDDY CURRENT SYSTEM FOR DETECTION OF CRACKING BENEATH BRAIDING IN CORRUGATED METAL HOSE

In this paper an eddy current system for the detection of partially-through-the-thickness cracks in corrugated metal hose is presented. Design criteria based upon the geometry and conductivity of the part are developed and applied to the fabrication of a prototype inspection system. Experimental data are used to highlight the capabilities of the system and an image processing technique is presented to improve flaw detection capabilities. A case study for detection of cracking damage in a space shuttle radiator retract flex hoses is also presented.

39↗

Quantifying the dislocation content of atomically resolved grain boundary line defects using the Nye tensor

The Nye tensor, which quantifies the density of Burgers vector for a given dislocation line direction, can be effectively used to characterize dislocation content in bulk crystals from atomic-resolution transmission electron microscopy images. The Nye tensor can be calculated from these images, in part because the reference state is simply defined by the lattice of the perfect crystal. The application of the Nye tensor to interfacial line defects, for which the natural reference state is the dichromatic pattern of the two grains in their reference orientation, poses additional challenges. In this work, we present a method that employs the Nye tensor to characterize the edge dislocation content of line defects at grain boundaries from atomic-resolution images. This approach enables us to rapidly characterize all edge dislocation content along a grain boundary. Additionally, the Nye tensor provides information about line defect core structure. Finally, we demonstrate this method on two exemplar defects: a twin boundary disconnection and a facet junction in face-centered cubic Au.

Crystallographic defects↗

Weakly supervised classification of aortic valve malformations using unlabeled cardiac MRI sequences

Biomedical repositories such as the UK Biobank provide increasing access to prospectively collected cardiac imaging, however these data are unlabeled, which creates barriers to their use in supervised machine learning. We develop a weakly supervised deep learning model for classification of aortic valve malformations using up to 4,000 unlabeled cardiac MRI sequences. Instead of requiring highly curated training data, weak supervision relies on noisy heuristics defined by domain experts to programmatically generate large-scale, imperfect training labels. For aortic valve classification, models trained with imperfect labels substantially outperform a supervised model trained on hand-labeled MRIs. In an orthogonal validation experiment using health outcomes data, our model identifies individuals with a 1.8-fold increase in risk of a major adverse cardiac event. This work formalizes a deep learning baseline for aortic valve classification and outlines a general strategy for using weak supervision to train machine learning models using unlabeled medical images at scale.

60 APPLIED LIFE SCIENCES↗

Imaging atomic-scale effects of high-energy ion irradiation on superconductivity and vortex pinning in Fe(Se,Te)

Maximizing the sustainable supercurrent density, J C , is crucial to high-current applications of superconductivity, and to achieve this, preventing dissipative motion of quantized vortices is key. Irradiation of superconductors with highenergy heavy ions can be used to create nanoscale defects that act as deep pinning potentials for vortices. This approach holds unique promise for high-current applications of iron-based superconductors because JC amplification persists to much higher radiation doses than in cuprate superconductors without significantly altering the superconducting critical temperature. However, for these compounds, virtually nothing is known about the atomic-scale interplay of the crystal damage from the high-energy ions, the superconducting order parameter, and the vortex pinning processes. We visualize the atomic-scale effects of irradiating FeSe x Te 1$-$x with 249-MeV Au ions and find two distinct effects: compact nanometer-sized regions of crystal disruption or “columnar defects,” plus a higher density of single atomic site “point” defects probably from secondary scattering. We directly show that the superconducting order is virtually annihilated within the former but suppressed by the latter. Simultaneous atomically resolved images of the columnar crystal defects, the superconductivity, and the vortex configurations then reveal how amixed pinning landscape is created, with the strongest pinning occurring at metallic core columnar defects and secondary pinning at clusters of point-like defects, followed by collective pinning at higher fields.

Critical Current by Design↗