Search NASA⌕ Search

SEARCH · Search NASA

Results for “deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

The Observed Variance Between Predicted and Measured Radiation Dose in Breast and Prostate Patients Utilizing an In Vivo Dosimeter

Purpose: Report the results of using a permanently implantable dosimeter in radiation therapy: determine specific adverse events, degree of migration, and acquire dose measurements during treatment to determine difference between expected and measured dose. Methods and Materials: The Dose Verification System is a wireless, permanently implantable metal-oxide semiconductor field-effect transistor dosimeter using a bidirectional antenna for power and data transfer. The study cohort includes 36 breast (33 patients received two devices) and 29 prostate (21 patients received two devices) cancer patients. A total of 1,783 and 1,749 daily dose measurements were obtained on breast and prostate patients, respectively. The measurements were compared with the planned expected dose. Biweekly computed tomography scans were obtained to evaluate migration and the National Cancer Institute's Common Toxicity Criteria, version 3, was used to evaluate adverse events. Results: Only Grade I/II adverse events of pain and bleeding were noted. There were only four instances of dosimeter migration of >5 mm from known factors. A deviation of {>=}7% in cumulative dose was noted in 7 of 36 (19%) for breast cancer patients. In prostate cancer patients, a {>=}7% deviation was noted in 6 of 29 (21%) and 8 of 19 (42%) during initial and boost irradiation, respectively. The two patterns of dose deviation were random and systematic. Some causes for these differences could involve organ movement, patient movement, or treatment plan considerations. Conclusions: The Dose Verification System was not associated with significant adverse events or migration. The dosimeter can measure dose in situ on a daily basis. The accuracy and utility of the dose verification system complements current image-guided radiation therapy and intensity-modulated radiation therapy techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Interfraction Prostate Motion Using Megavoltage Cone Beam Computed Tomography

Purpose: Determine the degree of interfraction prostate motion and its components measured by using daily megavoltage (MV) cone beam computed tomography (CBCT) imaging. Methods and Materials: A total of 984 daily MV CBCT images from 24 patients undergoing definitive intensity-modulated radiotherapy for localized prostate cancer were analyzed retrospectively. Pretreatment couch shifts, based on physician registration of MV CBCT to planning CT data sets, were used as a measure of daily interfraction motion. Off-line bony registration was performed to separate bony misalignment from internal organ motion. Interobserver and intraobserver variation studies were performed on 20 MV CBCT images. Results: Mean interfraction prostate motion was 6.7 mm, with the greatest single-axis deviation in the anterior-posterior (AP) direction. The largest positional inaccuracy was accounted for by systematic deviations in bony misalignment, whereas random deviations occurred from bony misalignment and internal prostate motion. In the aggregate, AP motion did not correlate with days elapsed since beginning therapy or on average with rectal size at treatment planning. Interobserver variation was greatest in the AP direction, decreased in experienced observers, and further decreased in intraobserver studies. Mean interfraction motion during the first 6 days of therapy, when used as a subsequent offset, reduced acceptable AP planning target volume margins by 50%. Conclusion: The MV CBCT is a practical direct method of daily localization that shows significant interfraction motion with respect to conventional three-dimensional conformal and intensity-modulated radiotherapy margins, similar to that measured in other modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deformation of Prostate and Seminal Vesicles Relative to Intraprostatic Fiducial Markers

Purpose: To quantify the residual geometric uncertainties after on-line corrections with intraprostatic fiducial markers, this study analyzed the deformation of the prostate and, in particular, the seminal vesicles relative to such markers. Patients and Methods: A planning computed tomography (CT) scan and three repeat CT scans were obtained for 21 prostate cancer patients who had had three to four cylindrical gold markers placed. The prostate and whole seminal vesicles (clinical target volume [CTV]) were delineated on each scan at a slice thickness of 1.5 mm. Rigid body transformations (translation and rotation) mapping the markers onto the planning scan positions were obtained. The translation only (T{sub only}) or both translation and rotation were applied to the delineated CTVs. Next, the residue CTV surface displacements were determined using nonrigid registration of the delineated contours. For translation and rotation of the CTV, the residues represented deformation; for T{sub only}, the residues stemmed from deformation and rotation. T{sub only} represented the residues for most currently applied on-line protocols. The patient and population statistics of the CTV surface displacements were calculated. The intraobserver delineation variation was similarly quantified using repeat delineations for all patients and corrected for. Results: The largest CTV deformations were observed at the anterior and posterior side of the seminal vesicles (population average standard deviation {<=}3 mm). Prostate deformation was small (standard deviation {<=}1 mm). The increase in these deviations when neglecting rotation (T{sub only}) was small. Conclusion: Although prostate deformation with respect to implanted fiducial markers was small, the corresponding deformation of the seminal vesicles was considerable. Adding marker-based rotational corrections to on-line translation corrections provided a limited reduction in the estimated planning margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Refinement of Treatment Setup and Target Localization Accuracy Using Three-Dimensional Cone-Beam Computed Tomography for Stereotactic Body Radiotherapy

Purposes: To quantitatively compare two-dimensional (2D) orthogonal kV with three-dimensional (3D) cone-beam CT (CBCT) for target localization; and to assess intrafraction motion with kV images in patients undergoing stereotactic body radiotherapy (SBRT). Methods and Materials: A total of 50 patients with 58 lesions received 178 fractions of SBRT. After clinical setup using in-room lasers and skin/cradle marks placed at simulation, patients were imaged and repositioned according to orthogonal kV/MV registration of bony landmarks to digitally reconstructed radiographs from the planning CT. A subsequent CBCT was registered to the planning CT using soft tissue information, and the resultant 'residual error' was measured and corrected before treatment. Posttreatment 2D kV and/or 3D CBCT images were compared with pretreatment images to determine any intrafractional position changes. Absolute averages, statistical means, standard deviations, and root mean square (RMS) values of observed setup error were calculated. Results: After initial setup to external marks with laser guidance, 2D kV images revealed vector mean setup deviations of 0.67 cm (RMS). Cone-beam CT detected residual setup deviations of 0.41 cm (RMS). Posttreatment imaging demonstrated intrafractional variations of 0.15 cm (RMS). The individual shifts in three standard orthogonal planes showed no obvious directional biases. Conclusions: After localization based on superficial markings in patients undergoing SBRT, orthogonal kV imaging detects setup variations of approximately 3 to 4 mm in each direction. Cone-beam CT detects residual setup variations of approximately 2 to 3 mm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multi-Institutional Trial of Accelerated Hypofractionated Intensity-Modulated Radiation Therapy for Early-Stage Oropharyngeal Cancer (RTOG 00-22)

Purpose: To assess the results of a multi-institutional study of intensity-modulated radiation therapy (IMRT) for early oropharyngeal cancer. Patients and Methods: Patients with oropharyngeal carcinoma Stage T1-2, N0-1, M0 requiring treatment of the bilateral neck were eligible. Chemotherapy was not permitted. Prescribed planning target volumes (PTVs) doses to primary tumor and involved nodes was 66 Gy at 2.2 Gy/fraction over 6 weeks. Subclinical PTVs received simultaneously 54-60 Gy at 1.8-2.0 Gy/fraction. Participating institutions were preapproved for IMRT, and quality assurance review was performed by the Image-Guided Therapy Center. Results: 69 patients were accrued from 14 institutions. At median follow-up for surviving patients (2.8 years), the 2-year estimated local-regional failure (LRF) rate was 9%. 2/4 patients (50%) with major underdose deviations had LRF compared with 3/49 (6%) without such deviations (p = 0.04). All cases of LRF, metastasis, or second primary cancer occurred among patients who were current/former smokers, and none among patients who never smoked. Maximal late toxicities Grade >=2 were skin 12%, mucosa 24%, salivary 67%, esophagus 19%, osteoradionecrosis 6%. Longer follow-up revealed reduced late toxicity in all categories. Xerostomia Grade >=2 was observed in 55% of patients at 6 months but reduced to 25% and 16% at 12 and 24 months, respectively. In contrast, salivary output did not recover over time. Conclusions: Moderately accelerated hypofractionatd IMRT without chemotherapy for early oropharyngeal cancer is feasible, achieving high tumor control rates and reduced salivary toxicity compared with similar patients in previous Radiation Therapy Oncology Group studies. Major target underdose deviations were associated with higher LRF rate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Verification of Calculated Skin Doses in Postmastectomy Helical Tomotherapy

Purpose: To verify the accuracy of calculated skin doses in helical tomotherapy for postmastectomy radiation therapy (PMRT). Methods and Materials: In vivo thermoluminescent dosimeters (TLDs) were used to measure the skin dose at multiple points in each of 14 patients throughout the course of treatment on a TomoTherapy Hi.Art II system, for a total of 420 TLD measurements. Five patients were evaluated near the location of the mastectomy scar, whereas 9 patients were evaluated throughout the treatment volume. The measured dose at each location was compared with calculations from the treatment planning system. Results: The mean difference and standard error of the mean difference between measurement and calculation for the scar measurements was -1.8% {+-} 0.2% (standard deviation [SD], 4.3%; range, -11.1% to 10.6%). The mean difference and standard error of the mean difference between measurement and calculation for measurements throughout the treatment volume was -3.0% {+-} 0.4% (SD, 4.7%; range, -18.4% to 12.6%). The mean difference and standard error of the mean difference between measurement and calculation for all measurements was -2.1% {+-} 0.2% (standard deviation, 4.5%: range, -18.4% to 12.6%). The mean difference between measured and calculated TLD doses was statistically significant at two standard deviations of the mean, but was not clinically significant (i.e., was <5%). However, 23% of the measured TLD doses differed from the calculated TLD doses by more than 5%. Conclusions: The mean of the measured TLD doses agreed with TomoTherapy calculated TLD doses within our clinical criterion of 5%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Role of Intra- or Periprostatic Calcifications in Image-Guided Radiotherapy for Prostate Cancer

Purpose: Image-guided radiotherapy (IGRT) allows more precise localization of the prostate, thus minimizing errors resulting from organ motion and set-up during treatment of prostate cancer. Using megavoltage cone-beam computed tomography (MVCBCT), references such as bones, the prostate itself or implanted fiducial markers can be used as surrogates to correct patient positioning immediately before each treatment fraction. However, the use of fiducials requires an invasive procedure and may increase costs. We aimed to assess whether intra- or periprostatic calcifications (IPC) could be used as natural fiducials. Methods and Materials: Data on patients treated with IGRT for prostate cancer with clearly visible IPC and implanted fiducials in both planning CT and MVCBCT images were reviewed. IPC were classified as central when inside the prostate and peripheral when within the planning target volume. Daily deviations in lateral, longitudinal, and vertical directions from baseline positioning using fiducials and using IPC were compared. Results: A total of 287 MVCBCT images were obtained and analyzed from 10 patients. The mean {+-} standard deviation daily deviation (mm) in the lateral, longitudinal, and vertical coordinates were 0.55 {+-} 3.11, 0.58 {+-} 3.45, and -0.54 {+-} 4.03, respectively, for fiducials, and 0.72 {+-} 3.22, 0.63 {+-} 3.58, and -0.69 {+-} 4.26, for IPC. The p values for comparisons (fiducials vs. IPC) were 0.003, 0.653, and 0.078 for lateral, longitudinal, and vertical coordinates, respectively. When cases with central IPC were analyzed (n = 7), no significant difference was found in such comparisons. Central IPC and fiducials exhibited a similar pattern of displacement during treatment, with equal values for daily displacements in the three directions for more than 90% of measurements. Conclusions: Our data suggest that centrally located IPC may be used as natural fiducials for treatment positioning during IGRT for prostate cancer, with potential reductions in the risks and costs associated with fiducial implantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MRI- Versus CT-Based Volume Delineation of Lumpectomy Cavity in Supine Position in Breast-Conserving Therapy: An Exploratory Study

Purpose: To examine magnetic resonance imaging (MRI) and computed tomography (CT) for lumpectomy cavity (LC) volume delineation in supine radiotherapy treatment position and to assess the interobserver variability. Methods and Materials: A total of 15 breast cancer patients underwent a planning CT and directly afterward MRI in supine radiotherapy treatment position. Then, 4 observers (2 radiation oncologists and 2 radiologists) delineated the LC on the CT and MRI scans and assessed the cavity visualization score (CVS). The CVS, LC volume, conformity index (CI), mean shift of the center of mass (COM), with the standard deviation, were quantified for both CT and MRI. Results: The CVS showed that MRI and CT provide about equal optimal visibility of the LC. If the CVS was high, magnetic resonance imaging provided more detail of the interfaces of the LC seroma with the unaffected GBT. MRI also pictured in more detail the interfaces of axillary seromas (if present) with their surroundings and their relationship to the LC. Three observers delineated smaller, and one observer larger, LC volumes comparing the MRI- and CT-derived delineations. The mean {+-} standard deviation CI was 32% {+-} 25% for MRI and 52% {+-} 21% for CT. The mean {+-} standard deviation COM shift was 11 {+-} 10 mm (range 1-36) for MRI and 4 {+-} 3 mm (range 1-10) for CT. Conclusions: MRI does not add additional information to CT in cases in which the CVS is assessed as low. The conformity (CI) is lower for MRI than for CT, especially at a low CVS owing to greater COM shifts for MRI, probably caused by inadequate visibility of the surgical clips on magnetic resonance (MR) images. The COM shifts seriously dictate a decline in the CI more than the variability of the LC volumes does. In cases in which MRI provides additional information, MRI must be combined with the CT/surgical clip data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of EORTC Target Definition Guidelines for Dose-Intensified Salvage Radiation Therapy for Recurrent Prostate Cancer: Results of the Quality Assurance Program of the Randomized Trial SAKK 09/10

Purpose: Different international target volume delineation guidelines exist and different treatment techniques are available for salvage radiation therapy (RT) for recurrent prostate cancer, but less is known regarding their respective applicability in clinical practice. Methods and Materials: A randomized phase III trial testing 64 Gy vs 70 Gy salvage RT was accompanied by an intense quality assurance program including a site-specific and study-specific questionnaire and a dummy run (DR). Target volume delineation was performed according to the European Organisation for the Research and Treatment of Cancer guidelines, and a DR-based treatment plan was established for 70 Gy. Major and minor protocol deviations were noted, interobserver agreement of delineated target contours was assessed, and dose-volume histogram (DVH) parameters of different treatment techniques were compared. Results: Thirty European centers participated, 43% of which were using 3-dimensional conformal RT (3D-CRT), with the remaining centers using intensity modulated RT (IMRT) or volumetric modulated arc technique (VMAT). The first submitted version of the DR contained major deviations in 21 of 30 (70%) centers, mostly caused by inappropriately defined or lack of prostate bed (PB). All but 5 centers completed the DR successfully with their second submitted version. The interobserver agreement of the PB was moderate and was improved by the DR review, as indicated by an increased κ value (0.59 vs 0.55), mean sensitivity (0.64 vs 0.58), volume of total agreement (3.9 vs 3.3 cm{sup 3}), and decrease in the union volume (79.3 vs 84.2 cm{sup 3}). Rectal and bladder wall DVH parameters of IMRT and VMAT vs 3D-CRT plans were not significantly different. Conclusions: The interobserver agreement of PB delineation was moderate but was improved by the DR. Major deviations could be identified for the majority of centers. The DR has improved the acquaintance of the participating centers with the trial protocol.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Results for Trigeminal Schwannomas Treated With Gamma Knife Surgery

Purpose: Surgical resection is considered the desirable curative treatment for trigeminal schwannomas. However, complete resection without any complications remains challenging. During the last several decades, stereotactic radiosurgery (SRS) has emerged as a minimally invasive treatment modality. Information regarding long-term outcomes of SRS for patients harboring trigeminal schwannomas is limited because of the rarity of this tumor. The aim of this study was to evaluate long-term tumor control and functional outcomes in patients harboring trigeminal schwannomas treated with SRS, specifically with gamma knife surgery (GKS). Methods and Materials: Fifty-three patients harboring trigeminal schwannomas treated with GKS were evaluated. Of these, 2 patients (4%) had partial irradiation of the tumor, and 34 patients (64%) underwent GKS as the initial treatment. The median tumor volume was 6.0 cm{sup 3}. The median maximum and marginal doses were 28 Gy and 14 Gy, respectively. Results: The median follow-up period was 98 months. On the last follow-up image, 7 patients (13%) had tumor enlargement, including the 2 patients who had partial treatment. Excluding the 2 patients who had partial treatment, the actuarial 5- and 10-year progression-free survival (PFS) rates were 90% and 82%, respectively. Patients with tumors compressing the brainstem with deviation of the fourth ventricle had significantly lower PFS rates. If those patients with tumors compressing the brainstem with deviation of the fourth ventricle are excluded, the actuarial 5- and 10-year PFS rates increased to 95% and 90%, respectively. Ten percent of patients had worsened facial numbness or pain in spite of no tumor progression, indicating adverse radiation effect. Conclusions: GKS can be an acceptable alternative to surgical resection in patients with trigeminal schwannomas. However, large tumors that compress the brainstem with deviation of the fourth ventricle should be surgically removed first and then treated with GKS when necessary.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Time-Adjusted Internal Target Volume: A Novel Approach Focusing on Heterogeneity of Tumor Motion Based on 4-Dimensional Computed Tomography Imaging for Radiation Therapy Planning of Lung Cancer

Purpose: To consider nonuniform tumor motion within the internal target volume (ITV) by defining time-adjusted ITV (TTV), a volume designed to include heterogeneity of tumor existence on the basis of 4-dimensional computed tomography (4D-CT). Methods and Materials: We evaluated 30 lung cancer patients. Breath-hold CT (BH-CT) and free-breathing 4D-CT scans were acquired for each patient. The tumors were manually delineated using a lung CT window setting (window, 1600 HU; level, −300 HU). Tumor in BH-CT images was defined as gross tumor volume (GTV), and the sum of tumors in 4D-CT images was defined as ITV-4D. The TTV images were generated from the 4D-CT datasets, and the tumor existence probability within ITV-4D was calculated. We calculated the TTV{sub 80} value, which is the percentage of the volume with a tumor existence probability that exceeded 80% on ITV-4D. Several factors that affected the TTV{sub 80} value, such as the ITV-4D/GTV ratio or tumor centroid deviation, were evaluated. Results: Time-adjusted ITV images were acquired for all patients, and tumor respiratory motion heterogeneity was visualized. The median (range) ITV-4D/GTV ratio and median tumor centroid deviation were 1.6 (1.0-4.1) and 6.3 mm (0.1-30.3 mm), respectively. The median TTV{sub 80} value was 43.3% (2.9-98.7%). Strong correlations were observed between the TTV{sub 80} value and the ITV-4D/GTV ratio (R=−0.71) and tumor centroid deviation (R=−0.72). The TTV images revealed the tumor motion pattern features within ITV. Conclusions: The TTV images reflected nonuniform tumor motion, and they revealed the tumor motion pattern features, suggesting that the TTV concept may facilitate various aspects of radiation therapy planning of lung cancer while incorporating respiratory motion in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Variance reduction for Fokker–Planck based particle Monte Carlo schemes

Recently, Fokker–Planck based particle Monte Carlo schemes have been proposed and evaluated for simulations of rarefied gas flows [1–3]. In this paper, the variance reduction for particle Monte Carlo simulations based on the Fokker–Planck model is considered. First, deviational based schemes were derived and reviewed, and it is shown that these deviational methods are not appropriate for practical Fokker–Planck based rarefied gas flow simulations. This is due to the fact that the deviational schemes considered in this study lead either to instabilities in the case of two-weight methods or to large statistical errors if the direct sampling method is applied. Motivated by this conclusion, we developed a novel scheme based on correlated stochastic processes. The main idea here is to synthesize an additional stochastic process with a known solution, which is simultaneously solved together with the main one. By correlating the two processes, the statistical errors can dramatically be reduced; especially for low Mach numbers. To assess the methods, homogeneous relaxation, planar Couette and lid-driven cavity flows were considered. For these test cases, it could be demonstrated that variance reduction based on parallel processes is very robust and effective.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

R-site varied series of RBaCo{sub 2}O{sub 5.5} (R{sub 2}Ba{sub 2}Co{sub 4}O{sub 11}) compounds with precisely controlled oxygen content

The entire family of carefully oxygen-adjusted RBaCo{sub 2}O{sub 5.5} or R{sub 2}Ba{sub 2}Co{sub 4}O{sub 11} (R=Y, Ho-La) double-perovskite oxides is systematically investigated for the lattice parameters, A-site cation disorder, and characteristic physical properties, i.e. the metal-insulator transition, ferromagnetic transition and so-called metamagnetic transition. With increasing size of the R constituent, the lattice parameters start to deviate from the linear behavior, indicating partial oxygen/vacancy and A-site cation disorder for the largest Rs of Nd, Pr and La. Both the metal-insulator transition and the two magnetic transitions are found to be highly sensitive to even minor deviations from the ideal 5.5 oxygen stoichiometry, thus underlining the importance of proper oxygen-content adjustment. - Graphical abstract: The entire family of carefully oxygen-adjusted RBaCo{sub 2}O{sub 5.5} (R=Y, La-Ho) double-perovskite cobalt oxides is systematically studied for lattice parameters and peculiar physical properties. The results indicate R/Ba cation and oxygen/vacancy disorders for the largest R constituents with Nd, Pr and La. The physical properties are found to be sensitive even for tiny deviations from the ideal 5.5 oxygen stoichiometry.

36 MATERIALS SCIENCE↗

Crystal structure and magnetic properties of '{alpha} Prime Prime -Fe{sub 16}N{sub 2}' containing residual {alpha}-Fe prepared by low-temperature ammonia nitridation

Slight enhancement of saturation magnetization to 219 A m{sup 2} kg{sup -1} was observed from 199 A m{sup 2} kg{sup -1} for the original {alpha}-Fe on the intermediate nitrided mixture of '{alpha} Prime Prime -Fe{sub 16}N{sub 2}' with residual {alpha}-Fe among the low temperature ammonia nitridation products under 5 T magnetic field at room temperature. The value changed not linearly against the yield as had been expected. Crystal structure refinement indicated that the phase similar to {alpha} Prime Prime -Fe{sub 16}N{sub 2} had deviations on its lattice constants and positional parameters, compared to previously reported values for {alpha} Prime Prime -Fe{sub 16}N{sub 2}. Spin-polarized total energy calculations were performed using the projector-augmented wave method as implemented in the Vienna ab-initio simulation package (VASP) to calculate magnetic moment on the refined crystal structure of the intermediate '{alpha} Prime Prime -Fe{sub 16}N{sub 2}'. The calculations supported the observed magnetization enhancement in the intermediate nitridation product. - Graphical abstract: Crystal structural parameters slightly change in the intermediate nitrided '{alpha} Prime Prime -Fe{sub 16}N{sub 2}' from those in {alpha} Prime Prime -Fe{sub 16}N{sub 2} to show the magnetization maxima in the mixture of '{alpha} Prime Prime -Fe{sub 16}N{sub 2}' and the residual {alpha}-F. Highlights: Black-Right-Pointing-Pointer Larger magnetization was observed than the value of Fe{sub 16}N{sub 2} on its intermediate nitrided mixture with residual {alpha}-Fe. Black-Right-Pointing-Pointer The enhancement was related to the crystal structural deviation from Fe{sub 16}N{sub 2} on the intermediate nitride. Black-Right-Pointing-Pointer It was supported by spin-polarized total energy calculation using the deviated structure.

36 MATERIALS SCIENCE↗

Structural and magnetic properties of RTiNO{sub 2} (R=Ce, Pr, Nd) perovskite nitride oxides

Neutron powder diffraction indicates that CeTiNO{sub 2} and PrTiNO{sub 2} crystallize with orthorhombic Pnma symmetry (Ce: a=5.5580(5), b=7.8369(7), and c=5.5830(4) Å; Pr: a=5.5468(5), b=7.8142(5), and c=5.5514(5) Å) as a result of a{sup –}b{sup +}a{sup –} tilting of the titanium-centered octahedra. Careful examination of the NPD data, confirms the absence of long range anion order in both compounds, while apparent superstructure reflections seen in electron diffraction patterns provide evidence for short range anion order. Inverse magnetic susceptibility plots reveal that the RTiNO{sub 2} (R=Ce, Pr, Nd) compounds are paramagnetic with Weiss constants that vary from −28 to −42 K. Effective magnetic moments for RTiNO{sub 2} (R=Ce, Pr, Nd) are 2.43 μ{sub B}, 3.63 μ{sub B}, and 3.47 μ{sub B}, respectively, in line with values expected for free rare-earth ions. Deviations from Curie–Weiss behavior that occur below 150 K for CeTiNO{sub 2} and below 30 K for NdTiNO{sub 2} are driven by magnetic anisotropy, spin–orbit coupling, and crystal field effects. - Graphical abstract: The structure and magnetism of the oxide nitride perovskites RTiNO{sub 2} (R=Ce, Pr, Nd) have been explored. The average symmetry is shown to be Pnma with a random distribution of oxide and nitride ions and a{sup −}b{sup +}a{sup −} tilting of the titanium-centered octahedra, but electron diffraction shows evidence for short range anion order. All three compounds are paramagnetic but deviations from the Curie Weiss law are seen below 150 K for R=Ce and below 30 K for R=Nd. - Highlights: • The oxide nitride perovskites RTiNO{sub 2} (R=Ce, Pr) have been prepared and their structures determined. • Diffraction measurements indicate short range cis-order of O and N, but no long range order. • Compounds are paramagnetic with Weiss constants that vary from −28 to −42 K. • CeTiO{sub 2}N and NdTiO{sub 2}N deviate from Curie–Weiss behavior below 150 and 30 K, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of sintering time on structural, microstructural and chemical composition of Ni-doped lanthanum gallate perovskites

This work reports the effect of two different sintering times, 6 and 48 h on the structural, microstructural, and chemical features of Ni-doped La{sub 0.90}Sr{sub 0.10}GaO{sub 3.00−δ}. Independently of the sintering time, La{sub 0.90}Sr{sub 0.10}Ga{sub 1−x}Ni{sub x}O{sub 3.00−δ} (where x=0.10, and 0.20 (mol)) presents a rhombohedral symmetry with a lattice volume that decreases when NiO dopant increases. Besides the perovskite, LaSrGa{sub 3.00}O{sub 7.00} (nominal composition) is present as second phase in all cases. When the samples are doped with NiO, the peaks of this second phase are shifted with respect to the peaks of the pure phase. These shifts suggest that this second phase could admit some Ni ions in its structure. According to the XRD patterns, the amount of the latter phase is larger when sintering time is increased. Electron probe microanalysis (EPMA) indicated that the matrix of the samples sintered for 6 h is constituted by a perovskite with an experimental composition very close to the nominal one. However, when the samples are sintered for 48 h the matrix of each sample is constituted by two perovskites; both with compositional deviations with respect to their nominal one. In particular, a significant Sr depletion compensated by a La increment in the A site is observed. Those compositional deviations could be mainly due to the diffusion of the cations in the bulk and/or from the bulk to the surface of the samples. That diffusion can favour the formation, not only, of a second perovskite with a different composition in relation with the first one formed, but also, the formation of second phases. In addition, a very slight broadening of Bragg peaks of the perovskites sintered for 48 h is observed by XRD and can be related to the presence of two different perovskites in each sample according to EPMA results. By BSEM and EPMA analyses La{sub 4.00}Ga{sub 2.00}O{sub 9.00} (nominal composition) is also observed as second phase when samples are treated for 48 h. - Graphical abstract: Typical microstructures, observed by FEG-SEM, of La{sub 0.90}Sr{sub 0.10}Ga{sub 1−x}Ni{sub x}O{sub 3.00−δ} materials with x=0.00 and 0.10 (nominal compositions) and sintered at 1450 °C for 48 h after polishing and thermal etching are shown. Lighter grey grains with a bimodal grain size are observed and according to XEDS analysis correspond to two perovskites with different experimental compositions (labelled as 1 and 2 for x=0.00 and labelled as 4 and 5 for x=0.10, respectively), meanwhile the darker grey phases correspond to LaSrGa{sub 3.00}O{sub 7.00} (labelled as 3 for x=0.00) and LaSr(Ga{sub 1−y′},Ni{sub y′}){sub 3.00}O{sub 7.00} (labelled as 6 for x=0.10), respectively. - Highlights: • When NiO is introduced into La{sub 0.90}Sr{sub 0.10}GaO{sub 3.00−δ} a change in symmetry is produced. • A significant Sr depletion in the A-site of perovskites treated for 48 h is observed. • Compositional deviations could be due to a thermally-activated diffusional process. • The phase purity of these materials is deteriorated when the sintering time is extended.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Growth kinetics of Al–Fe intermetallic compounds during annealing treatment of friction stir lap welds

In this study, we explored the growth kinetics of the Al–Fe intermetallic (IM) layer at the joint interface of the St-12/Al-5083 friction stir lap welds during post-weld annealing treatment at 350, 400 and 450 °C for 30 to 180 min. Optical microscope (OM), field emission gun scanning electron microscope (FEG-SEM) and transmission electron microscope (TEM) were employed to investigate the structure of the weld zone. The thickness and composition of the IM layers were evaluated using image analysis system and electron back-scatter diffraction (EBSD), respectively. Moreover, kernel average misorientation (KAM) analysis was performed to evaluate the level of stored energy in the as-welded state. The results showed that the growth kinetics of the IM layer was not governed by a parabolic diffusion law. Presence of the IM compounds as well as high stored energy near the joint interface of the as-welded sample was recognized to be the origin of the observed deviation from the parabolic diffusion law. - Highlights: • This work provided a new insight into growth kinetics of Al–Fe IM thickness. • The growth kinetics of IM layer was not governed by a parabolic diffusion law. • IM near the joint interface was the origin of deviation from the parabolic law. • High stored energy at joint interface was origin of deviation from parabolic law.

36 MATERIALS SCIENCE↗

Single crystal growth and structure refinements of CsM{sub x}Te{sub 2-x}O{sub 6} (M = Al, Ga, Ge, In) pyrochlores

Graphical abstract: Single crystals of CsM{sub x}Te{sub 2-x}O{sub 6} pyrochlores with M = Al, Ga, Ge, and In have been grown and structure refinements indicate deviations from ideal stoichiometry presumably related to mixed valency of tellurium. Highlights: {yields} Single crystals of CsM{sub x}Te{sub 2-x}O{sub 6} pyrochlores with M = Al, Ga, Ge, and In have been grown. {yields} Structure refinements from single crystal X-ray diffraction data confirm e structure. {yields} Deviations from ideal stoichiometry suggest mixed valency of tellurium and hence conductivity. -- Abstract: Single crystals of CsM{sub x}Te{sub 2-x}O{sub 6} pyrochlores with M = Al, Ga, Ge, and In have been grown from a TeO{sub 2} flux. Structure refinements from single crystal X-ray diffraction data are reported. These results are used to discuss deviations from ideal stoichiometry that result in electronic conductivity presumably related to mixed valency of tellurium.

36 MATERIALS SCIENCE↗