Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Sub-Planck structures and Quantum Metrology

The significance of sub-Planck structures in relation to quantum metrology is explored, in close contact with experimental setups. It is shown that an entangled cat state can enhance the accuracy of parameter estimations. The possibility of generating this state, in dissipative systems has also been demonstrated. Thereafter, the quantum Cramer-Rao bound for phase estimation through a pair coherent state is calculated, which achieves the maximum possible resolution in an interferometer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monitoring Surface Condition of Plasma Grid of a Negative Hydrogen Ion Source

Surface condition of a plasma grid in a negative hydrogen ion source is controlled so as to maximize the beam current under a discharge operation with introducing Cs into the ion source. Photoelectric current induced by laser beams incident on the plasma grid can produce a signal to monitor the surface condition, but the signal detection can be easily hindered by plasma noise. Reduction in size of a detection electrode embedded in the plasma grid can improve signal-to-noise ratio of the photoelectric current from the electrode. To evaluate the feasibility of monitoring surface condition of a plasma gird by utilizing photoelectric effect, a small experimental setup capable of determining quantum yields of a surface in a cesiated plasma environment is being assembled. Some preliminary test results of the apparatus utilizing oxide cathodes are reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Status and results from the OPERA experiment

The OPERA experiment is aiming at the first direct detection of neutrino oscillations in appearance mode through the study of the v{sub {mu}}{yields}v{tau} channel. The OPERA detector is placed in the CNGS long baseline v{sub {mu}} beam 730 km away from the neutrino source. The analysis of a sub-sample of the data taken in the 2008-2009 runs was completed After a brief description of the beam and the experimental setup, we report on event analysis and on a first candidate event, its background estimation and statistical significance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of the OLYMPUS Experiment at DESY

The OLYMPUS experiment at DESY, Hamburg, Germany will definitively determine the effect of two-photon exchange in elastic lepton-proton scattering by precisely measuring the ratio of positron-proton to electron-proton elastic unpolarized cross sections. In this paper, the physics motivation is summarized, aspects of the experimental setup are discussed and the current status and timeline of the project are reviewed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Airbreathing Laser Propulsion Experiments with 1 {mu}m Terawatt Pharos III Laser: Part 1

This basic research study examines the physics of airbreathing laser propulsion at the extreme flux range of 1-2x10{sup 11} W/cm{sup 2}--within the air breakdown threshold for l {mu}m radiation--using the terawatt PHAROS III neodymium-glass pulsed laser. Six different experimental setups were tested using a 34 mm line focus with 66 {mu}m focal waist, positioned near the flat impulse surface. The first campaign investigated impulse generation with the beam oriented almost normal to the target surface, with energies ranging from 23 to 376 J, and pulses of 5 to 30 ns FWHM. Air breakdown/ plasma dynamics were diagnosed with GOI cameras and color photography. Laser generated impulse was quantified with both vertical pendulums and piezoelectric pressure transducers using the standard performance metric, C{sub M}--the momentum coupling coefficient. Part 1 of this 2-part paper covers Campaign no. 1 results including laser plasma diagnostics, pressure gage and vertical pendulum data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Airbreathing Laser Propulsion Experiments with 1 {mu}m Terawatt Pharos IIILaser: Part 2

This basic research study examines the physics of airbreathing laser propulsion at the extreme flux range of 1-2x10{sup 11} W/cm{sup 2}--within the air breakdown threshold for l {mu}m radiation--using the terawatt Pharos III neodymium-glass pulsed laser. Six different experimental setups were employed using a 34 mm line focus with 66 {mu}m focal waist, positioned near the flat impulse surface. The 2nd Campaign investigated impulse generation with the laser beam focused at grazing incidence across near horizontal target surfaces, with pulse energies ranging from 55 to 186 J, and pulse-widths of 2 to 30 ns FWHM. Laser generated impulse was measured with a horizontal Plexiglas registered ballistic pendulum equipped with either a steel target insert or 0.5 Tesla permanent magnet (NEIT-40), to quantify changes in the momentum coupling coefficient (C{sub M}). Part 2 of this 2-part paper covers Campaign no. 2 results including C{sub M} performance data, and long exposure color photos of LP plasma phenomena.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Charge of particles in plasmas under external UV-radiation

In this experiment we investigate the charge of dust particles when they are exposed to external UV-radiation. The determination of the changes in charge of the dust particles is given by a combination of two methods to evaluate electrical charge: the resonance method and the normal mode analysis. This contribution describes the experimental setup and the determination of the charge differences.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Composition And Electrical Properties Of Dust From Tokamak Compass

In spite of the fact that fusion is a subject of the study for many years, there are still a lot of open questions. One of the interesting topics in fusion research is a presence of dust grains in reactors. In the paper, dust grains born in tokamak Compass are studied and compared with samples of a spherical geometry and well known composition. A unique experimental setup was used for investigations of charging properties of such grains and the SEM and EDX spectroscopy was applied for a study of grain composition. We focus on the secondary emission because this process plays a prominent role when a portion of energetic electrons is present in surroundings of a particular grain. It was shown that depending on the grain size and material, energetic electrons charge the grains to positive potentials comparable with the energy of impinging electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced light ion source extraction system for a new electron cyclotron resonance ion source geometry at Saclay

One of the main goal of intense light ion injector projects such as IPHI, IFMIF, or SPIRAL2, is to produce high current beams while keeping transverse emittance as low as possible. To prevent emittance growth induced in a dual solenoid low energy transfer line, its length has to be minimized. This can be performed with the advanced light ion source extraction system concept that we are developing: a new ECR 2.45 GHz type ion source based on the use of an additional low energy beam transport (LEBT) short length solenoid close to the extraction aperture to create the resonance in the plasma chamber. The geometry of the source has been considerably modified to allow easy maintenance of each component and to save space in front of the extraction. The source aims to be very flexible and to be able to extract high current ion beams at energy up to 100 kV. A specific experimental setup for this source is under installation on the BETSI test bench, to compare its performances with sources developed up to now in the laboratory, such as SILHI, IFMIF, or SPIRAL2 ECR sources. This original extraction source concept is presented, as well as electromagnetic simulations with OPERA-2D code. Ion beam extraction in space charge compensation regime with AXCEL, and beam dynamics simulation with SOLMAXP codes show the beam quality improvement at the end of the LEBT.

43 PARTICLE ACCELERATORS↗

X-ray reciprocal space mapping of dislocation-mediated strain relaxation during InGaAs/GaAs(001) epitaxial growth

Dislocation-mediated strain relaxation during lattice-mismatched InGaAs/GaAs(001) heteroepitaxy was studied through in situ x-ray reciprocal space mapping (in situ RSM). At the synchrotron radiation facility SPring-8, a hybrid system of molecular beam epitaxy and x-ray diffractometry with a two-dimensional detector enabled us to perform in situ RSM at high-speed and high-resolution. Using this experimental setup, four results in terms of film properties were simultaneously extracted as functions of film thickness. These were the lattice constants, the diffraction broadenings along in-plane and out-of-plane directions, and the diffuse scattering. Based on correlations among these results, the strain relaxation processes were classified into four thickness ranges with different dislocation behavior. In addition, the existence of transition regimes between the thickness ranges was identified. Finally, the dominant dislocation behavior corresponding to each of the four thickness ranges and transition regimes was noted.

36 MATERIALS SCIENCE↗

High Energy PIXE at the ARRONAX Facility for Multi Elemental Analysis of Thick Samples

Proton Induced X-ray Emission (PIXE) using high energy protons is a nondestructive multi-elemental technique that can analyze medium and heavy trace elements on thick samples. A new experimental setup is being built at the ARRONAX facility (Nantes, France) for this purpose. Experiments on multi-layer targets have been made in order to identify the sequences and to measure the different layer thicknesses. Our approach is to consider the relative intensities of K{alpha}/K{beta} lines in different layers as well as the gamma intensity ray ratio from each layer versus the reference layer. Two multi-layer targets were used: the first one composed of 10 {mu}m Au, 30{mu}m Bi and 250 {mu}m Cu, and the second composed of 125 {mu}m Ti, 10 {mu}m Au and 50 {mu}m Ag. In both cases, we used Al 100 {mu}m as a reference layer. This work emphasizes the importance of having both X-ray and gamma-ray information in multi-layer analyses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First commissioning results with the Grenoble test electron cyclotron resonance ion source at iThemba LABS

iThemba Laboratory for Accelerator Based Science (iThemba LABS) is a multi-disciplinary accelerator facility. One of its main activities is the operation of a separated-sector cyclotron with a K-value of 200, which provides beams of various ion species. These beams are used for fundamental nuclear physics research in the intermediate energy region, radioisotope production, and medical physics applications. Due to the requirements of nuclear physics for new ion species and higher energies, the decision was made to install a copy of the so-called Grenoble test source (GTS) at iThemba LABS. In this paper, we will report on the experimental setup and the first results obtained with the GTS2 at iThemba LABS.

43 PARTICLE ACCELERATORS↗

Delayed switching applied to memristor neural networks

Magnetic flux and electric charge are linked in a memristor. We reported recently that a memristor has a peculiar effect in which the switching takes place with a time delay because a memristor possesses a certain inertia. This effect was named the ''delayed switching effect.'' In this work, we elaborate on the importance of delayed switching in a brain-like computer using memristor neural networks. The effect is used to control the switching of a memristor synapse between two neurons that fire together (the Hebbian rule). A theoretical formula is found, and the design is verified by a simulation. We have also built an experimental setup consisting of electronic memristive synapses and electronic neurons.

97 MATHEMATICS AND COMPUTING↗

Optical emission spectroscopy of the Linac4 and superconducting proton Linac plasma generators

CERN's superconducting proton Linac (SPL) study investigates a 50 Hz high-energy, high-power Linac for H{sup -} ions. The SPL plasma generator is an evolution of the DESY ion source plasma generator currently operated at CERN's Linac4 test stand. The plasma generator is a step towards a particle source for the SPL, it is designed to handle 100 kW peak RF-power at a 6% duty factor. While the acquisition of an integrated hydrogen plasma optical spectrum is straightforward, the measurement of a time-resolved spectrum requires dedicated amplification schemes. The experimental setup for visible light based on photomultipliers and narrow bandwidth filters and the UV spectrometer setup are described. The H{sub {alpha}}, H{sub {beta}}, and H{sub {gamma}} Balmer line intensities, the Lyman band and alpha transition were measured. A parametric study of the optical emission from the Linac4 ion source and the SPL plasma generator as a function of RF-power and gas pressure is presented. The potential of optical emission spectrometry coupled to RF-power coupling measurements for on-line monitoring of short RF heated hydrogen plasma pulses is discussed.

43 PARTICLE ACCELERATORS↗

Normalization schemes for ultrafast x-ray diffraction using a table-top laser-driven plasma source

We present an experimental setup of a laser-driven x-ray plasma source for femtosecond x-ray diffraction. Different normalization schemes accounting for x-ray source intensity fluctuations are discussed in detail. We apply these schemes to measure the temporal evolution of Bragg peak intensities of perovskite superlattices after ultrafast laser excitation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gas gun shock experiments with single-pulse x-ray phase contrast imaging and diffraction at the Advanced Photon Source

The highly transient nature of shock loading and pronounced microstructure effects on dynamic materials response call for in situ, temporally and spatially resolved, x-ray-based diagnostics. Third-generation synchrotron x-ray sources are advantageous for x-ray phase contrast imaging (PCI) and diffraction under dynamic loading, due to their high photon fluxes, high coherency, and high pulse repetition rates. The feasibility of bulk-scale gas gun shock experiments with dynamic x-ray PCI and diffraction measurements was investigated at the beamline 32ID-B of the Advanced Photon Source. The x-ray beam characteristics, experimental setup, x-ray diagnostics, and static and dynamic test results are described. We demonstrate ultrafast, multiframe, single-pulse PCI measurements with unprecedented temporal (<100 ps) and spatial ({approx}2 {mu}m) resolutions for bulk-scale shock experiments, as well as single-pulse dynamic Laue diffraction. The results not only substantiate the potential of synchrotron-based experiments for addressing a variety of shock physics problems, but also allow us to identify the technical challenges related to image detection, x-ray source, and dynamic loading.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simultaneous surface plasmon resonance and x-ray absorption spectroscopy

We present an experimental setup for the simultaneous measurement of surface plasmon resonance (SPR) and x-ray absorption spectroscopy (XAS) on metallic thin films at a synchrotron beamline. The system allows measuring in situ and in real time the effect of x-ray irradiation on the SPR curves to explore the interaction of x-rays with matter. It is also possible to record XAS spectra while exciting SPR in order to study changes in the films induced by the excitation of surface plasmons. Combined experiments recording simultaneously SPR and XAS curves while scanning different parameters can be also carried out. The relative variations in the SPR and XAS spectra that can be detected with this setup range from 10{sup -3} to 10{sup -5}, depending on the particular experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modulated heterodyne light scattering set-up for measuring long relaxation time at small and wide angle

We present a simple, compact, and versatile experimental setup working in the heterodyne detection mode with modulation of the reference beam. The system is implemented with a collection optics based on a unimodal optical fiber coupler. This choice allows the heterodyne to be used in a wide range of scattering angles, even for very small ones, without losing the optical beating. The apparatus can be successfully used to study translational diffusive dynamics of dispersed particles at scattering angles smaller than 5 Degree-Sign and it is suitable for exploring slow relaxation processes in sub-Hertz frequency domain, for example, in glass-forming systems. It is also possible to measure the electrophoretic mobility by applying an electric field into a charged particles solution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗