Search NASA⌕ Search

SEARCH · Search NASA

Results for “filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Compact, Pneumatically Actuated Filter Shuttle

A compact, pneumatically actuated filter shuttle has been invented to enable alternating imaging of a wind-tunnel model in two different spectral bands characteristic of the pressure and temperature responses of a pressure and temperature-sensitive paint. This filter shuttle could also be used in other settings in which there are requirements for alternating imaging in two spectral bands. Pneumatic actuation was chosen because of a need to exert control remotely (that is, from outside the wind tunnel) and because the power leads that would be needed for electrical actuation would pose an unacceptable hazard in the wind tunnel. The entire shuttle mechanism and its housing can be built relatively inexpensively [<$500 (prices as of year 2000)] from off-the-shelf parts. The shuttle mechanism (see Figure 1) is contained in a housing that has dimensions of 4 by 6 by 2 in. (about 10 by 15 by 5 cm). Two 2-in. (=5-cm)-diameter standard scientific-grade band-pass filters are mounted on sliding panels in a dual-track frame. The mechanism is positioned and oriented so the panels slide sideways with respect to the optical axis of a charge-coupled-device camera used for viewing the wind-tunnel model. The mechanism includes a pneumatic actuator connected to a linkage. The linkage converts the actuator stroke to a scissor-like motion that places one filter in front of the camera and the other filter out of the way. Optoelectronic sensors detect tabs on the sliding panels for verification of the proper positioning of the filters.

Leighy, Bradley D.↗

Recursive Implementations of the Consider Filter

One method to account for parameters errors in the Kalman filter is to consider their effect in the so-called Schmidt-Kalman filter. This work addresses issues that arise when implementing a consider Kalman filter as a real-time, recursive algorithm. A favorite implementation of the Kalman filter as an onboard navigation subsystem is the UDU formulation. A new way to implement a UDU consider filter is proposed. The non-optimality of the recursive consider filter is also analyzed, and a modified algorithm is proposed to overcome this limitation.

Zanetti, Renato↗

Blocking Filters with Enhanced Throughput for X-Ray Microcalorimetry

New and improved blocking filters (see figure) have been developed for microcalorimeters on several mission payloads, made of high-transmission polyimide support mesh, that can replace the nickel mesh used in previous blocking filter flight designs. To realize the resolution and signal sensitivity of today s x-ray microcalorimeters, significant improvements in the blocking filter stack are needed. Using high-transmission polyimide support mesh, it is possible to improve overall throughput on a typical microcalorimeter such as Suzaku s X-ray Spectrometer by 11%, compared to previous flight designs. Using polyimide to replace standard metal mesh means the mesh will be transparent to energies 3 keV and higher. Incorporating polyimide s advantageous strength-to-weight ratio, thermal stability, and transmission characteristics permits thinner filter materials, significantly enhancing through - put. A prototype contamination blocking filter for ASTRO-H has passed QT-level acoustic testing. Resistive traces can also be incorporated to provide decontamination capability to actively restore filter performance in orbit.

Grove, David↗

Mass Conservation and Positivity Preservation with Ensemble-type Kalman Filter Algorithms

Maintaining conservative physical laws numerically has long been recognized as being important in the development of numerical weather prediction (NWP) models. In the broader context of data assimilation, concerted efforts to maintain conservation laws numerically and to understand the significance of doing so have begun only recently. In order to enforce physically based conservation laws of total mass and positivity in the ensemble Kalman filter, we incorporate constraints to ensure that the filter ensemble members and the ensemble mean conserve mass and remain nonnegative through measurement updates. We show that the analysis steps of ensemble transform Kalman filter (ETKF) algorithm and ensemble Kalman filter algorithm (EnKF) can conserve the mass integral, but do not preserve positivity. Further, if localization is applied or if negative values are simply set to zero, then the total mass is not conserved either. In order to ensure mass conservation, a projection matrix that corrects for localization effects is constructed. In order to maintain both mass conservation and positivity preservation through the analysis step, we construct a data assimilation algorithms based on quadratic programming and ensemble Kalman filtering. Mass and positivity are both preserved by formulating the filter update as a set of quadratic programming problems that incorporate constraints. Some simple numerical experiments indicate that this approach can have a significant positive impact on the posterior ensemble distribution, giving results that are more physically plausible both for individual ensemble members and for the ensemble mean. The results show clear improvements in both analyses and forecasts, particularly in the presence of localized features. Behavior of the algorithm is also tested in presence of model error.

EnKR↗

Optimization of OT-MACH Filter Generation for Target Recognition

An automatic Optimum Trade-off Maximum Average Correlation Height (OT-MACH) filter generator for use in a gray-scale optical correlator (GOC) has been developed for improved target detection at JPL. While the OT-MACH filter has been shown to be an optimal filter for target detection, actually solving for the optimum is too computationally intensive for multiple targets. Instead, an adaptive step gradient descent method was tested to iteratively optimize the three OT-MACH parameters, alpha, beta, and gamma. The feedback for the gradient descent method was a composite of the performance measures, correlation peak height and peak to side lobe ratio. The automated method generated and tested multiple filters in order to approach the optimal filter quicker and more reliably than the current manual method. Initial usage and testing has shown preliminary success at finding an approximation of the optimal filter, in terms of alpha, beta, gamma values. This corresponded to a substantial improvement in detection performance where the true positive rate increased for the same average false positives per image.

false alarm reduction↗

Concentric Split Flow Filter

A concentric split flow filter may be configured to remove odor and/or bacteria from pumped air used to collect urine and fecal waste products. For instance, filter may be designed to effectively fill the volume that was previously considered wasted surrounding the transport tube of a waste management system. The concentric split flow filter may be configured to split the air flow, with substantially half of the air flow to be treated traveling through a first bed of filter media and substantially the other half of the air flow to be treated traveling through the second bed of filter media. This split flow design reduces the air velocity by 50%. In this way, the pressure drop of filter may be reduced by as much as a factor of 4 as compare to the conventional design.

Stapleton, Thomas J.↗

Sequential Probability Ratio Test for Collision Avoidance Maneuver Decisions Based on a Bank of Norm-Inequality-Constrained Epoch-State Filters

Sequential probability ratio tests explicitly allow decision makers to incorporate false alarm and missed detection risks, and are potentially less sensitive to modeling errors than a procedure that relies solely on a probability of collision threshold. Recent work on constrained Kalman filtering has suggested an approach to formulating such a test for collision avoidance maneuver decisions: a filter bank with two norm-inequality-constrained epoch-state extended Kalman filters. One filter models 1he null hypothesis 1ha1 the miss distance is inside the combined hard body radius at the predicted time of closest approach, and one filter models the alternative hypothesis. The epoch-state filter developed for this method explicitly accounts for any process noise present in the system. The method appears to work well using a realistic example based on an upcoming highly-elliptical orbit formation flying mission.

Carpenter, J. R.↗

Design, Implementation, and Performance of the Astro-H Soft X-Ray Spectrometer Aperture Assembly and Blocking Filters

The calorimeter array of the JAXA Astro-H (renamed Hitomi) soft x-ray spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV. The properties that made the SXS array a powerful x-ray spectrometer also made it sensitive to photons from the entire electromagnetic band as well as particles. If characterized as a bolometer, it would have had a noise equivalent power of <4 × 10(exp −18) W/((Hz)(exp 0.5)). Thus, it was imperative to shield the detector from thermal radiation from the instrument and optical and UV photons from the sky. In addition, it was necessary to shield the coldest stages of the instrument from the thermal radiation emanating from the warmer stages. These needs were addressed by a series of five thin-film radiation-blocking filters, anchored to the nested temperature stages, that blocked long-wavelength radiation while minimizing x-ray attenuation. The aperture assembly was a system of barriers, baffles, filter carriers, and filter mounts that supported the filters and inhibited their potential contamination. The three outer filters also had been equipped with thermometers and heaters for decontamination. We present the requirements, design, implementation, and performance of the SXS aperture assembly and blocking filters.

Kilbourne, Caroline A.↗

Design of Optical/IR Blocking Filters for the Lynx X-Ray Microcalorimeter

The Lynx mission concept, under development ahead of the 2020 Astrophysics Decadal Review, includes the Lynx X-ray Microcalorimeter (LXM) as one of its primary instruments. The LXM uses a microcalorimeter array at the focus of a high-throughput soft x-ray telescope to enable high-resolution nondispersive spectroscopy in the soft x-ray waveband (0.2 to 15 keV) with exquisite angular resolution. Similar to other x-ray microcalorimeters, the LXM uses a set of blocking filters mounted within the dewar that pass the photons of interest (x-rays) while attenuating the out-of-band long-wavelength radiation. Such filters have been successfully used on previous orbital and suborbital instruments; however, the Lynx science objectives, which emphasize observations in the soft x-ray band (<1keV), pose more challenging requirements on the set of LXM blocking filters. We present an introduction to the design of the LXM optical/IR blocking filters and discuss recent advances in filter capability targeted at LXM. In addition, we briefly describe the external filters and the modulated x-ray sources to be used for onboard detector calibration.

Eckart, Megan E.↗

Fabrication of Phononic Filter Structures for Far-IR/sub-mm Detector Applications

A photon noise limited sub-mm/far-IR cold telescope in space will require detectors with noise equivalent power (NEP) less than 1x10-19W/Hz1/2for imaging applications and at least an order of magnitude lower for spectroscopic studies. The detector NEP can be reduced by lowering the operation temperature and improving the thermal isolation between the bolometer and a heat bath. We report on the fabrication of membrane isolated transition edge sensor bolometers incorporating compact (<50 μm) thermal isolation beams based on phononic filters. Phononic filters are created by etching quasi-periodic nanoscale structures into supporting thermo-mechanical beams. The cross-sectional dimensions of the etched features are less than the thermal wavelength at the operating temperature, enabling coherent phonon transport to take place in one dimension. The phonon stop-band can be tuned by adjusting the scale of the quasi-periodic structures. Cascading multiple filter stages can increase bandwidth and provide improved thermal isolation similar to the function of a multi-stage electrical filter. We describe the fabrication of AlMn based transition edge sensor bolometers on silicon and silicon nitride membranes isolated by one-and two-dimensional phononic filters. The phononic filters are patterned through electron beam lithography and isolated with deep reactive ion etching.

Phononic↗

Sequential Filtering in the Presence of Uniform Measurement Errors

This paper presents a sequential filtering strategy using observations corrupted with uniform measurement noise. While the Kalman filter remains the best linear estimator of the state, other filtering techniques provide minimum variance optimal estimates, a trait only enjoyed by the Kalman filter when the underlying noises are, in fact, Gaussian. This work develops a new approximate optimal estimator for uniform measurement noises. The resulting recursion requires just slightly more computational time to complete a measurement update than the Kalman filter, which generally cannot be claimed by other optimal strategies such as the particle or Gaussian mixture filters.

James S. McCabe↗

Sequential Filtering in the Presence of Uniform Measurement Errors

This paper presents a sequential filtering strategy using observations corrupted with uniform measurement noise. While the Kalman filter remains the best linear estimator of the state, other filtering techniques provide minimum variance optimal estimates, a trait only enjoyed by the Kalman filter when the underlying noises are, in fact, Gaussian. This work develops a new approximate optimal estimator for uniform measurement noises. The resulting recursion requires just slightly more computational time to complete a measurement update than the Kalman filter, which generally cannot be claimed by other optimal strategies such as the particle or Gaussian mixture filters.

James S McCabe↗

Face crack reduction strategy for particulate filters

A system comprises a particulate matter (PM) filter that comprises an upstream end for receiving exhaust gas, a downstream end and at least one portion. A control module initiates combustion of PM in the PM filter using a heater and selectively adjusts oxygen levels of the exhaust gas to adjust a temperature of combustion adjacent to the at least one portion of the PM filter. A method comprises providing a particulate matter (PM) filter that comprises an upstream end for receiving exhaust gas, a downstream end and at least one portion; initiating combustion of PM in the PM filter using a heater; selectively adjusting oxygen levels of the exhaust gas to adjust a temperature of combustion adjacent to the at least one portion of the PM filter.

42 ENGINEERING↗

METAL MEDIA FILTERS, AG-1 SECTION FI

One application of metal media filters is in various nuclear air cleaning processes including applications for protecting workers, the public and the environment from hazardous and radioactive particles. To support this application the development of the ASME AG-1 FI Standard on Metal Media has been under way for more than ten years. Development of the proposed section has required resolving several difficult issues associated with operating conditions (media velocity, pressure drop, etc.), qualification testing, and quality acceptance testing. Performance characteristics of metal media are dramatically different than the glass fiber media with respect to parameters like differential pressures, operating temperatures, media strength, etc. These differences make existing data for a glass fiber media inadequate for qualifying a metal media filter for AG-1. In the past much work has been conducted on metal media filters at facilities such as Lawrence Livermore National Laboratory (LLNL) and Savannah River National Laboratory (SRNL) to qualify the media as High Efficiency Particulate Air (HEPA) Filters. Particle retention testing has been conducted at Oak Ridge Filter Test Facility and at Air Techniques International (ATI) to prove that the metal media meets or exceeds the 99.97% particle retention required for a HEPA Filter. Even with his testing, data was lacking to complete an AG-1 FI Standard on metal media. With funding secured by Mississippi State University (MSU) from National Nuclear Security Administration (NNSA), a research test stand is being designed and fabricated at MSU's Institute for Clean Energy Technology (ICET) Facility to obtain qualification data on metal media. This in turn will support required data needed for the FI Standard. The paper will discuss in detail how the test stand at MSU will obtain the necessary data to complete the FI Standard.

42 ENGINEERING↗

Variable bandwidth filter

A variable bandwidth filter is described herein, wherein a bandwidth of a passband of the variable bandwidth filter is dynamically tunable. The variable bandwidth tuner is implemented on a CMOS chip, and acts to filter analog signals. The variable bandwidth filter comprises a plurality of finite impulse response (FIR) filters, wherein each FIR filter comprises a plurality of tunable transconductors. The tunable transconductors are tunable in their gain.

Rodenbeck, Christopher T.↗

Method for concentrating solids and removing solids from a filter medium

Disclosed are methods for concentrating solids and removing solids from a filter medium. The method includes the step of concentrating first particles of a first solid by removing a fluid stream through a filter medium in a filter. At least some of the first particles become blocking particles that block pores of the filter medium. The method also includes the step of inserting second particles of a second solid into the filter. These second particles scrape, vibrate, agglomerate, or a combination thereof along the filter medium, thus dislodging at least a portion of the blocking particles.

Frankman, David↗

Hydrophobic Filter Material for Nuclear Material Transportation and Storage Containers - 17518

Los Alamos National Laboratory has begun development of hydrophobic or super-hydrophobic inorganic filter materials that resist water ingress after exposure to radiation and/or elevated temperature. Filters that are currently available depend on carbon composites and/or organic polymers for their water resistant/hydrophobic properties to minimize water ingress. However, facility and transportation accident scenarios often include fire, impact and subsequent water spray or flooding conditions. A purely inorganic hydrophobic filter material could have enhanced resistance to fire and radiation damage, and continue to minimize water ingress after such an accident. Such filters could broaden the use of filtered containers in the transportation and storage of nuclear materials, and could have broader implications in other industrial applications. The goal is to create a porous inorganic material with hydrophobic properties that maintains or exceeds the current performance criteria for particulate filtration efficiency, pressure differential, air flow and hydrogen diffusion. The materials developed in this project show promise in evaluations for use as enhancements to the SAVY 4000 nuclear storage container that is becoming widely used around the DOE complex. Preliminary results indicate that the treated filters provide resistance to a water column pressure test and have filtration efficiencies and air flow pressure drops that meet the current performance criteria. There are various treatment options being tested to help determine the best path forward. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of High Strength HEPA Filters for Use in Demanding Air and Gas Streams - 17644

High-efficiency particulate air (HEPA) filters are used in a wide variety of applications, including the removal of radioactive particulate from process off-gas streams and the venting of waste storage containers. Porvair Filtration Group, specializing in the design and manufacture of robust filters in numerous industries, has worked to develop HEPA filter designs for use in such high-demand nuclear process-gas and air streams. Using the requirements of section FK of the American Society of Mechanical Engineers AG-1 Code on Nuclear Air and Gas Treatment (ASME AG-1) as a guide, Porvair Filtration Group has designed filters which can withstand upset conditions to include elevated temperatures, high relative humidity, high particle-loading, and an unconventionally high differential pressure across the filter media; while maintaining excellent removal efficiencies. The process by which Porvair Filtration Group has reached optimized designs was based upon an extended test and development program. Design, manufacture, and testing of flat sheet media samples, geometrically equivalent model filters, and full-scale prototypes was performed at several Porvair Filtration Group facilities located in the United States and the United Kingdom. The methods and results of this development program are outlined in the following paper. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗