Search NASA⌕ Search

SEARCH · Search NASA

Results for “forensics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Hair Proteome Variation at Different Body Locations on Genetically Variant Peptide Detection for Protein-Based Human Identification

Abstract Human hair contains minimal intact nuclear DNA for human identification in forensic and archaeological applications. In contrast, proteins offer a pathway to exploit hair evidence for human identification owing to their persistence, abundance, and derivation from DNA. Individualizing single nucleotide polymorphisms (SNPs) are often conserved as single amino acid polymorphisms in genetically variant peptides (GVPs). Detection of GVP markers in the hair proteome via high-resolution tandem mass spectrometry permits inference of SNPs with known statistical probabilities. To adopt this approach for forensic investigations, hair proteomic variation and its effects on GVP identification must first be characterized. This research aimed to assess variation in single-inch head, arm, and pubic hair, and discover body location-invariant GVP markers to distinguish individuals. Comparison of protein profiles revealed greater body location-specific variation in keratin-associated proteins and intracellular proteins, allowing body location differentiation. However, robust GVP markers derive primarily from keratins that do not exhibit body location-specific differential expression, supporting GVP identification independence from hair proteomic variation at the various body locations. Further, pairwise comparisons of GVP profiles with 8 SNPs demonstrated greatest interindividual variation and high intraindividual consistency, enabling similar differentiative potential of individuals using single hairs irrespective of body location origin.

59 BASIC BIOLOGICAL SCIENCES↗

Single-particle chemical analysis reveals organic-rich detonation soot products

The detonation of high explosives produces a wide variety of particulate matter (PM) with distinct properties, not all of which are traditionally studied for chemical composition, formation processes, and forensic applications. We report particle-resolved measurements of Composition B detonation soot using soot particle aerosol mass spectrometry (SP-AMS), identifying carbonaceous species and metals not previously characterized on a single-particle basis. Results are combined with scanning electron microscopy with energy dispersive X-ray spectroscopy (SEM-EDS) to enhance source-dependent signatures. Black carbon, including graphitic carbon and detonation nanodiamonds, contributed 50.5-71.4% of PM 2.5 mass, while 22.5-43.4% was non-refractory organic carbon, a previously overlooked component that exhibited a complex and varying composition. Detonations were performed with and without PMMA confinement and under steady and overdriven conditions. Distinct particles enriched with polycyclic aromatic hydrocarbons (PAHs) were observed in experiments utilizing confinement, with quantities dependent on manufacturing method. SEM-EDS validated SP-AMS findings of metals internally mixed with carbonaceous species and extended the particle size range to 100 µm. This work makes detecting non-refractory organics using single-particle techniques more feasible for detonation forensics and understanding high-energy soot formation. While this analysis uses offline sample collection, SP-AMS could be deployed for in-situ measurements of detonation PM 2.5 transported in the atmosphere.

36 MATERIALS SCIENCE↗

Time-resolved imaging of atoms and molecules in laser-produced uranium plasmas

Gas-phase oxidation of uranium (U), plume chemistry, and its impact on optical emission features of the uranium plasma are investigated. Plasmas were produced via nanosecond laser ablation of a natural uranium target in a chamber where uranium oxidation was controlled by varying the oxygen partial pressure within argon cover gas. Monochromatic imaging of uranium atoms and monoxide molecules was performed using narrowband optical filters, which clearly reveals the spatio-temporal evolution of these species in the plasma. Uranium oxides are found to be formed at the plasma edges, where lower temperatures favor molecular recombination. Segregation between the distribution of uranium atoms and monoxide species is observed at later times of plasma evolution, and is more apparent at lower oxygen partial pressures. At higher oxygen partial pressures, significant variation in plume morphology is noticed for UO species, which is attributed to higher rate of oxide (UxOy) formation at the plume edges. The monochromatic images of U atoms and molecules and corresponding spectral features at various oxygen partial pressures presented here provide a unique insight into gas-phase, high-temperature uranium oxidation, and its chemistry and have implications for a wide range of nuclear applications, from stand-off detection of radioisotopes to forensics and safeguards.

(140.3440) Laser-induced breakdown, (280.4788) Opt↗

National and International Security Applications of Cryogenic Detectors - Mostly Nuclear Safeguards

As with science, so with security--in both arenas, the extraordinary sensitivity of cryogenic sensors enables high-confidence detection and high-precision measurement even of the faintest signals. Science applications are more mature, but several national and international security applications have been identified where cryogenic detectors have high potential payoff. International safeguards and nuclear forensics are areas needing new technology and methods to boost speed, sensitivity, precision and accuracy. Successfully applied, improved nuclear materials analysis will help constrain nuclear materials diversion pathways and contribute to treaty verification. Cryogenic microcalorimeter detectors for X-ray, gamma-ray, neutron, and alpha-particle spectrometry are under development with these aims in mind. In each case the unsurpassed energy resolution of microcalorimeters reveals previously invisible spectral features of nuclear materials. Preliminary results of quantitative analysis indicate substantial improvements are still possible, but significant work will be required to fully understand the ultimate performance limits.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Laser Particle Accelerator Development at LANL: From Fast Ignition to Radiation Oncology

Laser-plasma accelerated ion and electron beam sources are an emerging field with vast prospects, and promise many superior applications in a variety of fields such as hadron cancer therapy, compact radioisotope generation, table-top nuclear physics, laboratory astrophysics, nuclear forensics, waste transmutation, Special Nuclear Material (SNM) detection, and inertial fusion energy. LANL is engaged in several projects seeking to develop compact high-current and high-energy ion and electron sources. We are especially interested in two specific applications: ion fast ignition/capsule perturbation and radiation oncology. Laser-to-beam conversion efficiencies of over 10% are needed for practical applications, and we have already shown inherent efficiencies of >5% from flat foils, on Trident using only a 5th of the intensity and energy of the Nova Petawatt laser. With clever target designs, like structured curved cone targets, we have also been able to achieve major ion energy gains, leading to the highest energy laser-accelerated proton beams in the world [3]. These new target designs promise to help usher in the next generation of particle sources realizing the potential of laser-accelerated beams.

43 PARTICLE ACCELERATORS↗

Gamma and Decay Energy Spectroscopy Measurements of Trinitite

We report gamma-ray spectroscopy measurements of trinitite samples and analogous samples obtained from detonation sites in Nevada and Semipalatinsk, as well as in situ measurements of topsoil at the Trinity site. We also report the first isotopic composition measurements of trinitite using the novel forensics technique of decay energy spectroscopy (DES) as a complement to traditional forensics techniques. Our gamma spectroscopy and DES measurements are compared to other published results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Mixed Element Microparticle Characterization by Electron Probe Microanalysis

Abstract Microparticle compositional characterization for nuclear forensics has traditionally been achieved by “gold-standard” destructive analytical techniques such as large geometry-secondary ion mass spectrometry and fission track-thermal ionization mass spectrometry, but long processing times and total sample consumption eliminate the option of subsequent analysis by other methods. Electron probe microanalysis has long been widely employed for rapid, nondestructive, micrometer-scale compositional measurements and imaging in fields such as material science and geology and may therefore need to be reevaluated as an alternative tool for microparticle analysis for the nuclear forensics community. This study presents the use of electron probe microanalysis for imaging and quantitative characterization of homogeneous microparticles utilizing a calibration curve based on high-precision quadrupole-inductively coupled plasma-mass spectrometry analyses. Samples of opportunity synthesized at Savannah River National Laboratory, nickel-doped cerium oxide microparticles, were selected as analogs for plutonium-doped uranium oxide microparticles. Positive detection and accurate quantification of variable amounts of nickel dopant down to trace levels (10s of parts per million) suggest applicability of this technique to other mixed element systems (e.g., actinides). Quantitative single-particle characterization via electron probe microanalyzer may thus provide a high fidelity, nondestructive complement to techniques currently in use.

Riche, Alexis T. (ORCID:0009000121978126)↗

Diagnosis of PV Cell Antireflective Coating Degradation Resulting From Hot-Humid High-Voltage Potential Aging

Corrosion of the antireflective coating on a photovoltaic cell ("ARc corrosion") has previously been observed in studies using hot-humid test conditions with external high-voltage (HV) bias. This study primarily focuses on known vulnerable legacy aluminum back surface field cells in mini-modules (MiMos) put through comparative stepped stress tests. Each cell type had MiMos at +1500 V, -1500 V, or unbiased ("Voc") potential, which were sequentially subjected to test conditions of 60 degrees C/60% relative humidity (RH) for 96 h, as in International Electrotechnical Commission Technical Specification 62804-1; 70 degrees C/70% RH for 200 h; and 85 degrees C/85% RH for 200 h. Characterizations at each step included visual camera and electroluminescence (EL) imaging, colorimetry, and current-voltage curve tracing. Final characterizations included: Suns-Voc, spatial mapping of external quantum efficiency, high-resolution photoluminescence, EL, and dark lock-in thermography imaging. Forensics were performed on extracted cores, including scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS), X-ray photoelectron spectroscopy, and scanning Auger microscopy (SAM). Forensics were also conducted on MiMos from previous studies that underwent stepped HV aging and separate outdoor aged full-sized modules. ARc corrosion was specifically seen for the glass/encapsulant/cell side of the +1500 V (HV+) stressed MiMos and modules. Appearance, color, and reflectance were the most distinguishing characteristics relative to glass corrosion, gridline corrosion and delamination, and other concurrent degradation modes. SEM/EDS and SAM identified the conversion of silicon nitride to hydrated silica, hydrous silica, or hydrated amorphous silica, which preferentially occurred at the edges and tips of the pyramidal textured cell surface.

14 SOLAR ENERGY↗

High performance radiation transport simulations: Preparing for TITAN

In this paper we describe the Denovo code system. Denovo solves the six-dimensional, steady-state, linear Boltzmann transport equation, of central importance to nuclear technology applications such as reactor core analysis (neutronics), radiation shielding, nuclear forensics and radiation detection. The code features multiple spatial differencing schemes, state-of-the-art linear solvers, the Koch-Baker-Alcouffe (KBA) parallel-wavefront sweep algorithm for inverting the transport operator, a new multilevel energy decomposition method scaling to hundreds of thousands of processing cores, and a modern, novel code architecture that supports straightforward integration of new features. In this paper we discuss the performance of Denovo on the 20+ petaflop ORNL GPU-based system, Titan. We describe algorithms and techniques used to exploit the capabilities of Titan's heterogeneous compute node architecture and the challenges of obtaining good parallel performance for this sparse hyperbolic PDE solver containing inherently sequential computations. Numerical results demonstrating Denovo performance on early Titan hardware are presented.

Baker, C.↗

Development of Fast Decay-Energy Spectroscopy With Magnetic Microcalorimeters

Decay energy spectroscopy (DES) is an increasingly important radiometric technique arising from the unique thermal detection physics and the precision of low-temperature microcalorimetry. DES can enable high-precision analysis of very small amounts of radioactive material with simple and rapid sample preparation, making it a key new tool for nuclear safeguards, nuclear forensics, the improvement of nuclear data, measurements of absolute activity, and other applications. For problems in nuclear safeguards and nuclear forensics it is highly desirable to increase the count rates achievable in DES, while maintaining simple and rapid sample preparation. Here, in this report, we describe progress in a new project to achieve high count rates in DES by taking advantage of the physics of magnetic microcalorimetry. We describe the results of initial modeling and experiment to validate the idea, a sample fabrication technique suitable for nuclear materials laboratories, the preparation and initial tests of paramagnetic Au-Er alloy in thin foil form, and the development of a sensing coil geometry that will perform well with the increased-thickness sensor used in the new technique.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Power of Exclusion using Automated Osteometric Sorting: Pair‐Matching,

Abstract This study compares the original pair‐matching osteometric sorting model ( J Forensic Sci 2003 ;48:717) against two new models providing validation and performance testing across three samples. The samples include the Forensic Data Bank, USS Oklahoma , and the osteometric sorting reference used within the Defense POW / MIA Accounting Agency. A computer science solution to generating dynamic statistical models across a commingled assemblage is presented. The issue of normality is investigated showing the relative robustness against non‐normality and a data transformation to control for normality. A case study is provided showing the relative exclusion power of all three models from an active commingled case within the Defense POW / MIA Accounting Agency. In total, 14,357,220 osteometric t ‐tests were conducted. The results indicate that osteometric sorting performs as expected despite reference samples deviating from normality. The two new models outperform the original, and one of those is recommended to supersede the original for future osteometric sorting work.

Lynch, Jeffrey James↗

Reanalysis of the Trotter Tibia Quandary and its Continued Effect on Stature Estimation of Past‐Conflict Service Members

Abstract Forensic casework from past‐conflicts relies on the corrected historical Trotter data for stature estimation in Fordisc. For roughly 10 years’, stature estimation using this data has produced point estimates for the tibia that are on average 1.25 inches less than the other long bones. This issue was identified after applying the equations derived from Fordisc to the USS Oklahoma commingled assemblage. Reevaluation of Fordisc revealed that a correction factor of 20 mm, instead of 10 mm, was mistakenly applied to the Trotter tibia data. Historical forensic anthropology reports written at the Defense POW / MIA Accounting Agency were utilized to identify that the overcorrection is isolated to Fordisc 3 with an error rate of 5% of known antemortem statures falling outside of the prediction intervals that relied on the tibia. Further evaluation of the Oklahoma sample indicates the 10 mm correction is still producing point estimates less than the other long bones.

Lynch, Jeffrey James↗

Scanning transmission x-ray microscopy (STXM) of plutonium oxide

Scanning transmission x-ray microscopy was used to examine plutonium oxide particles formed by the corrosion of δ-phase plutonium alloy under high-humidity conditions. O K-edge spectra collected from eight distinct particles displayed significant spectral differences, revealing heterogeneity in oxidation states within a single sample batch. Here, this variation suggests complex chemical environments and formation histories, which are important considerations for nuclear forensic investigations. These findings highlight both the potential of synchrotron-based x-ray microscopy for nondestructive, high-resolution analysis of nuclear materials and the need for expanded reference datasets to improve the interpretation and forensic utility of such measurements.

organic↗

Akatosh: Automated Cyber Incident Verification and Impact Analysis

Akatosh, a U.S. Department of Homeland Security Transition to Practice Program (TTP) project developed by Oak Ridge National Laboratory with industry and academic partnership, enables automated, real-time forensic analysis of endpoints after malware-attacks and other cyber security incidents by automatically maintaining detailed snapshots of host-level activity on endpoints over time. It achieves this by integrating intrusion detection systems (IDS) with forensic tools. The combination allows Akatosh to collect vast amounts of endpoint data and assists in verifying, tracking, and analyzing endpoints in real time. This provides operations personnel and analysts as well as managers and executives with continuous feedback on the impact of malicious software and other security incidents on endpoints in their network.

Smith, Jared M.↗

Bayesian Integration of Isotope Ratios for Geographic Sourcing of Castor Beans

Recent years have seen an increase in the forensic interest associated with the poison ricin, which is extracted from the seeds of the Ricinus communis plant. Both light element (C, N, O, and H) and strontium (Sr) isotope ratios have previously been used to associate organic material with geographic regions of origin. We present a Bayesian integration methodology that can more accurately predict the region of origin for a castor bean than individual models developed independently for light element stable isotopes or Sr isotope ratios. Our results demonstrate a clear improvement in the ability to correctly classify regions based on the integrated model with a class accuracy of 6 0 . 9 {+-} 2 . 1 % versus 5 5 . 9 {+-} 2 . 1 % and 4 0 . 2 {+-} 1 . 8 % for the light element and strontium (Sr) isotope ratios, respectively. In addition, we show graphically the strengths and weaknesses of each dataset in respect to class prediction and how the integration of these datasets strengthens the overall model.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect of Plutonium on Uranium Oxide Microstructural Fingerprint

The analysis of particulates from environmental sampling is routinely performed for nuclear forensics applications. In order to increase the tools available for nuclear forensics applications, capability development materials (CDMs), or reference particulates, are necessary for developing and benchmarking new analytical methods. Historically, these CDM particulates have been produced with highly controlled and characterized isotopic and size parameters for applications in developing and benchmarking particle sizers and mass spectrometry analytical methods [1- 4]. However, the development of CDMs with highly characterized particle morphology and phase of the particles is vital for aiding in the development and benchmarking of particle analytical methods for those parameters. In many cases, key properties such as crystallographic phase, morphology, and microstructure, may be correlated to processing history of environmental sampling particulates [5]. To that end, this work investigates determining the structural fingerprint of produced Pu-doped uranium oxide CDMs using transmission electron microscopy (TEM). The particulates, one of which shown in Figure 1, were synthesized to Fig. 1. Single particulate of uranium oxide fabricated using the THESEUS technique. develop capabilities for environmental sampling investigations. These particles are monodisperse at diameter of 1 μm and a range of plutonium concentrations from 0- 1,000 ppm. Given their small diameter, TEM analysis was ideal for studying the particulate structural fingerprint in detail. Previous investigations confirmed the external homogeneity of the particulates at different plutonium concentrations, however this analysis focuses on determining the grain structure, phase distribution, and porosity of the particulates.

Mayer, Jack [Univ. of Florida, Gainesville, FL (Un↗

Analysis of chemical warfare agents by gas chromatography-mass spectrometry: methods for their direct detection and derivatization approaches for the analysis of their degradation products

Abstract Chemical warfare agents (CWAs) are unarguably one of the most feared toxic substances produced by mankind. Their inception in conventional warfare can be traced as far back as the Middle Ages but their full breakthrough as central players in bellic conflicts was not realized until World War I. Since then, more modern CWAs along with efficient methods for their manufacture have emerged and violently shaped the way modern warfare and diplomatic relations are conducted. Owing to their mass destruction ability, counter methods to mitigate their impact appeared almost immediately on par with their development. These efforts have focused on their efficient destruction, development of medical countermeasures and their detection by modern analytical chemistry methods. The following review seeks to provide the reader with a broad introduction on their direct detection by gas chromatography-mass spectrometry (GC-MS) and the various sample derivatization methods available for the analysis of their degradation products. The review concentrates on three of the main CWA classes and includes the nerve agents, the blistering agents and lastly, the incapacitating agents. Each section begins with a brief introduction of the CWA along with discussions of reports dealing with their detection in the intact form by GC-MS. Furthermore, as products arising from their degradation carry as much importance as the agents themselves in the field of forensic analysis, the available derivatization methods of these species are presented for each CWA highlighting some examples from our lab in the Forensic Science Center at the Lawrence Livermore National Laboratory.

Valdez, Carlos A.↗

Rapid Analyses of Sparse Seismoacoustic Data Reveals the Timing and Size of the Accurate Energetic Systems Explosion

On 10 October 2025 an explosion occurred at a facility operated by Accurate Energetic Systems in Humphreys County, Tennessee. The incident resulted in 16 fatalities and created a debris field over several square kilometers. To address remaining questions about explosion timing and size, we collected about 20 seismic and 19 acoustic records of the blast from sensors up to hundreds of kilometers away. We then deployed 10 distinct physics-based, reduced order models (ROMs) that used validated geological structure and atmospheric conditions from the time of the event, along with observations of body- and surface-wave energy, as well as acoustic overpressure and phase duration. Each ROM predicted either timing, yield estimates, or both. We binned these estimates and their uncertainties according to each ROMs’ assumptions about confinement (aboveground, buried fully coupled, and buried partially coupled) and combined these estimates with other forensic data to conclude that the event occurred as a single, aboveground explosion on 10 December 2025 12:47:50.8 ±0.1 s with a yield equivalent to 11.8 [2.3,16.5] tons of Trinitrotoluene. Our estimates align with the Bureau of Alcohol, Tobacco, Firearms and Explosives inventory reports of 11–13 tons. This multimethod approach demonstrates the use of remotely observed geophysical data to rapidly aid conventional forensic investigations of accidental explosions.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗