Search NASA⌕ Search

SEARCH · Search NASA

Results for “grid simulator testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Simulated Inlet Unstart and Nacelle/Diverter Effects for the Boeing Reference H Configuration

The Boeing Reference H configuration was tested in the NASA Ames 9x7 Supersonic Wind Tunnel. A simulated unstarted inlet was evaluated as well as the aerodynamic performance of the configuration with and without nacelle and diverter components. These experimental results were compared with computational results from the unstructured grid Euler flow solver AIRPLANE. The comparisons between computational and experimental results were good, and demonstrated that the Euler code is capable of efficiently and accurately predicting the changes in the aerodynamic coefficients associated with inlet unstart and the effects of the nacelle and diverter components.

Cliff, Susan E.↗

Computational Fluid Dynamics Simulation of Dual Bell Nozzle Film Cooling

Marshall Space Flight Center (MSFC) and Armstrong Flight Research Center (AFRC) are working together to advance the technology readiness level (TRL) of the dual bell nozzle concept. Dual bell nozzles are a form of altitude compensating nozzle that consists of two connecting bell contours. At low altitude the nozzle flows fully in the first, relatively lower area ratio, nozzle. The nozzle flow separates from the wall at the inflection point which joins the two bell contours. This relatively low expansion results in higher nozzle efficiency during the low altitude portion of the launch. As ambient pressure decreases with increasing altitude, the nozzle flow will expand to fill the relatively large area ratio second nozzle. The larger area ratio of the second bell enables higher Isp during the high altitude and vacuum portions of the launch. Despite a long history of theoretical consideration and promise towards improving rocket performance, dual bell nozzles have yet to be developed for practical use and have seen only limited testing. One barrier to use of dual bell nozzles is the lack of control over the nozzle flow transition from the first bell to the second bell during operation. A method that this team is pursuing to enhance the controllability of the nozzle flow transition is manipulation of the film coolant that is injected near the inflection between the two bell contours. Computational fluid dynamics (CFD) analysis is being run to assess the degree of control over nozzle flow transition generated via manipulation of the film injection. A cold flow dual bell nozzle, without film coolant, was tested over a range of simulated altitudes in 2004 in MSFC's nozzle test facility. Both NASA centers have performed a series of simulations of that dual bell to validate their computational models. Those CFD results are compared to the experimental results within this paper. MSFC then proceeded to add film injection to the CFD grid of the dual bell nozzle. A series of nozzle pressure ratios and film coolant flow rates are investigated to determine the effect of the film injection on the nozzle flow transition behavior. The results of this CFD study of a dual bell with film injection are presented in this paper.

Braman, Kalen↗

Sensitivity-Based Reactive Power Dispatch of DERs to Support Transmission Grid During Emergency

This paper proposes a TSO-DSO framework including DER set-point dispatch using sensitivity analysis. We address all three steps of TSO-DSO integration stating by estimating the capability curve of an unbalanced distribution system and then modeling of capability curve on the transmission side grid and estimating the reactive power needed from DSO during emergencies, and ending by dispatching the requested reactive power from TSO. The proposed interaction framework is tested on an IEEE 37-node distribution network connected to IEEE 9 bus transmission system. The simulation shows that using sensitivity-based dispatch would reduce the number of communication signals between DERs and DSO and that can decrease the risk of communication contingency.

Alkhonain, Ahmed↗

Inverter Controls for Smooth Transition Operation and Voltage Balancing of Networked Microgrids

With increasing penetrations of distributed energy resources (DERs), researchers have extensively studied the formation and networking of microgrids to improve reliability during distribution system outages. However, these operations might require DERs in the microgrids to switch between grid-following (GFL) and grid-forming (GFM) modes of operation. A smooth transition between the operation modes should be ensured to have a stable system operation and to avoid nuisance tripping. Additionally, as we network microgrids, inverter control schemes with voltage-balancing controls are needed for unbalanced distribution networks. This paper presents the design of a GFM and GFL capable inverter control scheme for reliable operation in networked microgrids with mechanisms for 1) smooth transition between the GFL and GFM modes, and 2) negative sequence voltage control for voltage balancing. Using electromagnetic transient (EMT) simulations, the control scheme is first tested on a simple two-source power system using a digital real-time simulator. Next, a real-world distribution feeder with unbalanced loading and multiple DERs is used to demonstrate stable operation during the networking of microgrids with voltage balance support.

distributed energy resources↗

Flow Characterization of the NASA Langley Unitary Plan Wind Tunnel, Test Section 2: Computational Results

This is an abstract for an invited paper at the AIAA Aviation Conference, June 2021. The work described here is part of an effort of coordinated experiments in the Unitary Plan Wind Tunnel (UPWT) facility at the NASA Langley Research Center (LaRC) and matching CFD simulations. The primary goal of the work is to assess the productivity and true predictive accuracy of CFD, absent any guidance from experiment, in the high supersonic speed range as compared to experiments performed at the NASA LaRC’s UPWT facility. This report concerns CFD simulation of the primary flow-path in the empty wind tunnel, including the settling chamber, nozzle, test section, and some of the tunnel downstream of the test section. The Mach number in the test section ranges from M~2.4 to M~4.6, and the required area ratio variation is achieved by translation of a nozzle block which constricts the area of a loosely S-shaped throat. Flow past protuberances in the settling chamber and into this S-bend throat are predicted by CFD to generate streamwise vorticity that may, or may not, persist through the throat and into the test section as coherent vortices. Some flow conditions are notably unsteady at frequencies well below those of turbulence, due to unsteady separated flow ahead of the nozzle block. The bulk flow moves at velocities ranging from 'walking speed' in the settling chamber to M~4.6 in the test section. Heat transfer to the settling chamber walls and buoyancy are significant at high Mach number. Subtle variations in surface curvature in the nozzle generate Mach waves that propagate into the test section. CFD of the empty tunnel serves two purposes. Firstly, the full-tunnel simulations are used to provide upstream boundary conditions for CFD of vehicle aerodynamics which are generally performed in a domain confined to the wind tunnel test section; these companion studies are addressed in other papers. Secondly, it is a challenging test for CFD to resolve all of the empty tunnel flow phenomena relevant to flow in the test section. It requires a more complete definition of geometry than was originally anticipated. In addition, it requires good spatial and temporal accuracy, and turbulence modeling that performs well on specific phenomena such as corner flows. The boundary conditions and solution algorithms must perform well from incompressible to almost hypersonic speeds. The final state of the pre-test CFD was a product of an iterative self-improvement process. The initial simulations of the empty tunnel were deficient in many respects, but hints to those deficiencies were recognized in the solutions, and remedies were implemented. Possible further improvements will be studied in the post-test phase when comparisons with experimental data are possible. The CFD was performed by five separate collaborative teams using four different flow solvers: FUN3D, Overflow, Star-CCM+ and USM3D. The level of effort of these teams varied significantly, but each made important contributions to the goals of the work. A concerted effort to use uncertainty quantification methods (UQ) in CFD is also a goal of this work. To this end, variations in CFD results due to grid refinement, turbulence modeling, and boundary conditions have been characterized. Code-to-code variation is another means of assessing CFD uncertainty. All CFD solvers predict similarity among the primary flow features; these include the variation of Mach number due to changes in Reynolds number, and the bulk flow angularity due to tunnel-wall curvature. All CFD solvers also predict similar trends in secondary flows, such as the downwash in the side-wall boundary layers. Three of the high-spatial resolution simulations give similar predictions of a complex secondary flow phenomena, streamwise vortices generated in the S-bend throat that persist into the side-wall boundary layers of the test section. Two of the highest-resolution simulations, run with the same turbulence model in different CFD solvers, gave encouragingly similar predictions of a complex tertiary flow phenomenon, small transient "sprites" of upwash flows, resulting from vortices that presumably originate in the separated flow near the leading edge of the nozzle block. While the CFD was done in a "blind pre-test" mode, requests from the experimental team for CFD results pertaining to unsteadiness and total temperature variations in the test section resulted in CFD runs that included a cooled wall in settling chamber. This then led to a change in the standard practice for running the Overflow results, which would not have occurred without this "release" of this experimental information. CFD was also used to guide some measurements. The paper will focus on establishing the consensus among CFD results and understanding differences among those results. Initial findings from the efforts to characterize CFD uncertainty have been done and will be included in the paper.

Robert Edward Childs↗

LDES-Sizing-and-siting-model (Power grid test cases for long-duration energy storage (LDES) siting) [SWR-25-75]

This repository contains code and data for performing a siting analysis of long-duration energy storage (LDES) in the 5-bus and RTS systems using the Sienna suite developed by the National Renewable Energy Laboratory for production cost modeling (PCM). This analysis involves moving the LDES component to different buses in the system, running a simulation, and considering the production cost of the simulation. Different system configurations are also analyzed with these scripts (such as moving load or renewable dispatch generators to different buses) to observe the impacts the system configuration has on optimal siting. This repository contains three sub directories discussed below. Both the 5-bus and RTS systems have two different initial configurations for the renewable energy components in them, one that is predominantly PV-driven and one that is predominantly wind-driven. Sienna suite can be found here: https://github.com/NREL-Sienna

Cole, David [University of Wisconsin]↗

Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) (Final Scientific/Technical Report)

This report summarizes the activities conducted under the DOE VTO funded project DE- EE0008451, where ABB Inc. (ABB), in collaboration with Idaho National Laboratory (INL), APS Global (APS), and XOS Trucks (XOS) pursued the development of a cyber-resilient extreme fast charging (XFC) management system. This project entitled Cybersecurity for Grid Connected eXtreme Fast Charging (XFC) Station (CyberX) focuses on a resilient architecture for smart charging EV Supply Equipment (EVSE) device control and Coordinated Anomaly Detection System (CADS) features that can be added at the charging site depot level to increase cybersecurity. The project was split into two budget periods focused first on developing the threat model and resilient control concepts and second on testing, improving, and validating those developed resilient control algorithms and features with a focus on key vulnerabilities identified during the threat assessment portion of the project. During the first budget period of the CyberX project, the ABB led team focused on activities to identify, model, and quantitatively prioritize high-impact attack scenarios with potential cyber-physical effects while also modeling and developing concepts for a resilient control system that could securely address integration of DERs and other resources with EV charging. Development of the security focused XFC management system (XMS) was accomplished first by offline simulation using a developed XFC station or depot with 480V input level and simulating measurement inputs to monitoring and control systems in concept development. A representative distribution grid model was developed supporting an EV charging site model with BESS and 6 general EV charging models. These EV charging models allowed multiple configurations of charging level, multiple connected protection and measurement devices, and simulation function to show general compromise of EV, BESS, and protection features based on parallel threat analysis. During the second budget period, the EV site and supporting systems model was developed in more detail and converted from offline model to real-time to real-time with EV charging hardware in the loop (HIL). The resilient control architecture developed as concept in the first part of the project was further tested and validated for integration of local energy resources and XFC charging station site equipment while maintaining cybersecure operating principles. The proposed resilient architecture for smart charging and cybersecurity features consists of two main concepts developed and tested within the project. The first concept is an XFC management system (XMS) consisting of a hardware gateway, software platform, and Supervisory Control and Data Acquisition (SCADA) or Distribution Management System integration components. The second concept is a Coordinated Anomaly Detection System (CADS) which forms a primarily software-related subsystem of the total CyberX solution focused on monitoring system measurements, estimation of measurement states, and predicting current at the utility point of interaction based on machine learning for anomaly detection.

33 ADVANCED PROPULSION SYSTEMS↗

Representing Fine‐Scale Topographic Effects on Surface Radiation Balance in Hyper‐Resolution Land Surface Models

Land surface models are increasingly used to simulate land surface processes at hyper-spatial resolutions (e.g., ∼1 km). As model resolution increases, grid-scale topographic effects on surface radiation fluxes and their interactions between adjacent grids become more pronounced. However, current land surface models routinely neglect the fine-scale topographic effects on surface radiation balance. This study developed physically-based and computationally-efficient parameterizations (fineTOP) that explicitly resolve fine-scale topographic effects on downward shortwave and longwave radiation as well as land surface radiative properties. The newly developed parameterizations were implemented and tested in the Energy Exascale Earth System Model (E3SM) Land Model (ELM). Multi-decadal km-resolution ELM simulations over the California Sierra Nevada show that fine-scale topography significantly impacts the surface energy balance and snow processes across seasons. Slope determines the magnitude of topographic effects, while aspect controls their sign. For slopes larger than 30°, topography-induced change in annual surface temperature can be as large as 3.3 K. Regionally, the mean value and standard deviation of topography-induced changes in annual surface temperature are −0.22 ± 0.38 K and +0.25 ± 0.37 K over north-facing and south-facing slopes, respectively. Topography-induced changes in surface radiative properties account for 3.5% ± 13.8% of total topographic effects on annual net radiation. With fineTOP, ELM captures the aspect-dependence of snow cover fraction, snow water equivalent, and land surface temperature found in MODIS satellite observations and a snow reanalysis data set, while the default ELM fails to capture this phenomenon. The enhanced capability to represent fine-scale topographic effects on surface radiation balance can be used to advance understanding of the role of fine-scale topography in land surface processes and land-atmosphere interactions over mountainous regions.

Hao, Dalei [Pacific Northwest National Laboratory ↗

Efficient Topology Assessment for Integrated Transmission and Distribution Network with 10,000+ Inverter-based Resources

The renewable energy proliferation calls upon the grid operators and planners to systematically evaluate the potential impacts of distributed energy resources (DERs). Considering the significant differences between various inverter-based resources (IBRs), especially the different capabilities between grid-forming inverters and grid-following inverters, it is crucial to develop an efficient and effective assessment procedure besides available co-simulation framework with high computation burdens. This paper presents a streamlined graph-based topology assessment for the integrated power system transmission and distribution networks. Graph analyses were performed based on the integrated graph of modified miniWECC grid model and IEEE 8500-node test feeder model, high performance computing platform with 40 nodes and total 2400 CPUs has been utilized to process this integrated graph, which has 100,000+ nodes and 10,000+ IBRs. The node ranking results not only verified the applicability of the proposed method, but also revealed the potential of distributed grid forming (GFM) and grid following (GFL) inverters interacting with the centralized power plants.

Graph Analysis, Topology evaluation, Infrastructur↗

Design of Zone-Based Hierarchical Protection System for 100% Renewable Microgrids

Design of a reliable and secure protection system for a 100% renewable microgrid with only inverter-based resources (IBRs), is quite challenging. Most of the existing protection schemes in the state-of-the-art are suitable for microgrids with mixed-type of distributed energy resources (DERs) that covers both rotating machine-based DERs as well as IBR-based DERs, where the fault current level is moderately high. Due to drastic reduction in fault current level based on mode of operation and the variation of the low fault current level based on the operating level of the IBRs, the existing protection schemes face critical challenges, in case of a 100% renewable microgrid. This article proposes a zone-based hierarchical protection scheme that partitions a microgrid into various zones-of-protection and assigns speed-based hierarchical protection schemes in order to address the fundamental challenges of such microgrids. The performance of the proposed scheme is evaluated using time-domain simulation study on a microgrid test system. The results corroborates that the proposed hierarchical zone-based protection scheme exhibits enhanced reliability, security and dependability while tested with various fault cases (fault types, locations, and impedances), and non-fault cases during both grid-tied and islanded mode.

grid-forming inverter↗

Evaluating Implementations of the Immersed Boundary Method in the Weather Research and Forecasting Model

The terrain-following coordinate system used by many atmospheric models can cause numerical instabilities due to discretization errors as resolved terrain slopes increase and the grid becomes highly skewed. The immersed boundary (IB) method, which does not require the grid to conform to the terrain, has been shown to alleviate these errors, and has been used successfully for high-resolution atmospheric simulations over steep terrain, including vertical building surfaces. Since many previous applications of IB methods to atmospheric models have used very fine grid resolution (5 m or less), the present study seeks to evaluate IB method performance over a range of grid resolutions and aspect ratios. Two classes of IB algorithms, velocity reconstruction and shear stress reconstruction, are tested within the common framework of the Weather Research and Forecasting (WRF) Model. Performance is evaluated in two test cases, one with flat terrain and the other with the topography of Askervein Hill, both under neutrally stratified conditions. WRF-IB results are compared to similarity theory, observations, and native WRF results. Despite sensitivity to the location at which the IB intersects the model grid, the velocity reconstruction IB method shows consistent performance when used with a hybrid RANS/LES surface scheme. The shear stress reconstruction IB method is not sensitive to the grid intersection, but is less consistent and near-surface velocity errors can occur at coarse resolutions. This study represents an initial investigation of IB method variability across grid resolutions in WRF. Future work will focus on improving IB method performance at intermediate to coarse resolutions.

54 ENVIRONMENTAL SCIENCES↗

National Renewable Energy Laboratory (NREL) Topic 2 Final Report: End-to-End Communication and Control System to Support Clean Energy Technologies

This document is the final report of a two-year development, test, and demonstration project, 'Cohesive Application of Standards- Based Connected Devices to Enable Clean Energy Technologies.' The project was part of the National Renewable Energy Laboratory's (NREL's) Integrated Network Testbed for Energy Grid Research and Technology (INTEGRATE) initiative hosted at Energy Systems Integration Facility (ESIF). This project demonstrated techniques to control distribution grid events using the coordination of traditional distribution grid devices and high-penetration renewable resources and demand response. Using standard communication protocols and semantic standards, the project examined the use cases of high/low distribution voltage, requests for volt-ampere-reactive (VAR) power support, and transactive energy strategies using Volttron. Open source software, written by EPRI to control distributed energy resources (DER) and demand response (DR), was used by an advanced distribution management system (ADMS) to abstract the resources reporting to a collection of capabilities rather than needing to know specific resource types. This architecture allows for scaling both horizontally and vertically. Several new technologies were developed and tested. Messages from the ADMS based on the common information model (CIM) were developed to control the DER and DR management systems. The OpenADR standard was used to help manage grid events by turning loads off and on. Volttron technology was used to simulate a homeowner choosing the price at which to enter the demand response market. Finally, the ADMS used newly developed algorithms to coordinate these resources with a capacitor bank and voltage regulator to respond to grid events.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Medium Voltage Testbed for Comparing Advanced Power Line Sensors vs. Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. These devices measure phase voltages and currents and are commissioned by electrical engineers. PTs/CTs can detect and react to various electrical anomalies that could adversely affect electrical grid operations. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medium-voltage sensor is compared with that of a reference PT and a CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the U.S. Department of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with an integrator for current monitoring. This study simulated a power grid model based on a utility circuit at the Riverside EPB of Chattanooga. The simulation circuit was created with MATLAB/Simulink software and was integrated into an RT-LAB project to run with the OP4510 real-time simulator at the OPLST. During the tests, the real-time simulations were run for 40 s, and the signal to record the test event with the power meter was set at 30 s for the event-trigger circuit. The advanced outdoor power line sensor testbed has a real-time simulator that is used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, and service restoration), while the analog signals are recorded by the same high-resolution power meter. The behaviors of analog signals, harmonic components, total harmonic distortion, and crest factors are assessed for this power line sensor and compared with those of the reference PT/CT because of the absence of testing standards for advanced outdoor power line sensors. The results showed that this OPLS technology responded identically to the PT and CT under all conditions.

Piesciorovsky, Emilio [ORNL]↗

A comparison of two algorithms for simulating collisionless systems

Two completely different simulation algorithms are compared by applying them to the same stellar dynamical problems: one is a self-consistent field (SCF) method for solving Poisson's equation and the other is a phase-space method for integrating the collisionless Boltzmann equation. We consider simulations of spherical stellar systems which are initially far from equilibrium and relax to their final states by gravitational collapse. The initial conditions consist of either uniform-density spheres or nonequilibrium models having Plummer density profiles, in which velocity dispersions are assigned according to given virial ratios. If a few tens of radial expansion terms with hundreds of thousands of particles are used in the SCF code, excellent agreement is found between the results it generates and those obtained with the phase-space solver, provided that a sufficiently large number of grid cells are employed with the latter. These findings imply that for simulating collisionless systmes over many dynamical times, the SCF approach based on sampling phase space is competitive with the approach treating phase space as a continuous fluid. The results of our tests make it possible to estimate the number of particles and basis functions required in situations like those modeled. Limitations of the SCF method and the choice of an optimal set of basis functions are also discussed.

Hozumi, Shunsuke↗

State of the AGN: Progress Toward Understanding Black Hole Accretion Processes

Accretion of plasma onto black holes power some of the most powerful systems in the cosmos. Supermassive black holes at the centers of galaxies represent the high-mass limit of these objects and so account for the most luminous accretors. As a result, their influence spans vast spatial and temporal scales of cosmic phenomena: intracluster heating, intergalactic media, galactic feedback and star formation, kiloparsec-scale jets/outflows, variability over time scales of minutes to centuries, and luminous multi-wavelength electromagnetic emission extending all the way down to its event horizon. Their intrigue is heightened by the fact that they lie at the intersection of various physical laws---e.g., general relativistic gravity, magnetohydrodynamics, radiation, high-energy particle physics, thermodynamics, and photo-ionization---which all must be reconciled to arrive at a fundamental understanding and probe for new physics, like tests of general relativity. These physics ingredients must be incorporated into simulations performed somehow on dynamical scales ranging from that of the event horizon to parsec-scales. Fortunately, new computational and theoretical techniques---such as GPU computing, radiation transport, and and novel gridding techniques---are enabling progress to larger scales, more degrees of freedom, and even to binary systems. Some of the topics we will survey include recent progress on simulating the relationship between the disk-jet interaction, how tilted black holes behave, radiation-dominated flow, and how binary AGN affect the standard picture of black hole accretion. Along the way, we will highlight how new technologies have enabled these scientific rewards. Future directions and open questions will be provided to inspire discussion and interaction during the session.

LISA↗

Provision of Grid Services by PV Plants with Integrated Battery Energy Storage System: Preprint

Battery energy storage systems (BESS), due to their tremendous range of uses and configurations, may assist PV integration in any number of ways by increasing power system flexibility. In this paper we describe results of a research project conducted by NREL and First Solar for developing controls and demonstrating many use cases for PV-BESS systems including (1) matching generation to loads through time shifting, reducing PV curtailment,; (2) promoting higher levels of PV penetrations by balancing the grid through ancillary services; (3) use of PV-BESS systems to provide wide-area stability services in the form of oscillations damping controls; and (r) use of gird forming BESS for enabling black start and islanded applications for PV-BESS systems. In the paper we will also describe the unique multi-MW test and validation platform developed at NREL for conducting research on fielded utility-scale PV-BESS systems. The platform consists of First Solar 0.43 MW PV power plant, NREL’s 1MW/1MW BESS, 2MW PV power supplies and 7MVA power electronic grid simulator interfaced with industrial plant controllers and power-hardware-in-the-loop (PHIL) capability.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Design of Zone-Based Hierarchical Protection System for 100% Renewable Microgrids: Preprint

Design of a reliable and secure protection system for a 100% renewable microgrid with only inverter-based resources (IBRs), is quite challenging. Most of the existing protection schemes in the state-of-the-art are suitable for microgrids with mixed-type of distributed energy resources (DERs) that covers both rotating machine-based DERs as well as IBR-based DERs, where the fault current level is moderately high. Due to drastic reduction in fault current level based on mode of operation and the variation of the low fault current level based on the operating level of the IBRs, the existing protection schemes face critical challenges, in case of a 100% renewable microgrid. This article proposes a zone-based hierarchical protection scheme that partitions a microgrid into various zones-of-protection and assigns speed-based hierarchical protection schemes in order to address the fundamental challenges of such microgrids. The performance of the proposed scheme is evaluated using time-domain simulation study on a microgrid test system. The results corroborates that the proposed hierarchical zone-based protection scheme exhibits enhanced reliability, security and dependability while tested with various fault cases (fault types, locations, and impedances), and non-fault cases during both grid-tied and islanded mode.

grid-forming inverter↗

Accelerating Nuclear-Integrated Data Centers in the USA: SWOT Analysis, Power-Thermal Management Strategies, and Industrial-Scale Demonstration and Potential Deployment

Driven by the growth in digital services, cloud computing, AI, and manufacturing, data centers face rising energy demands that challenge traditional power sources and cooling efficiency. This study explores using nuclear power to meet these demands, focusing on accelerated reactor technology deployment and highlighting needs such as N+1/N+2 power supplies and integrated power-thermal management. A SWOT analysis addresses grid connectivity, reactors, and site selection, particularly DOE sites. Reactor technology demonstration and deployment could be accelerated by leveraging test facilities such as MARVEL, MAGNET, TED, FAS, DOME, LOTUS, ATR, Energy System Proving Grounds, and upcoming Energy Launch Pads, along with modeling and simulation tools such as RELAP5, MOOSE, VERA, RAVEN, and FORCE. The potential power and thermal management options, including various cooling technologies, waste-heat utilization, and an industrial-scale demonstration plan, aim to accelerate the integration of nuclear power and data centers in the USA, while emphasizing community and stakeholder engagement and synergistic efforts.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗