Search NASA⌕ Search

SEARCH · Search NASA

Results for “inexpensive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Low-Cost Humidity Sensor

Electronic humidity sensor is simple, inexpensive, and produces output readily used by indicator or control circuits. Sensor operates at safe, low voltage and is relatively invulnerable to electrolysis effects. Sensor used to measure humidity in atmosphere, in soil, and industrial gases, for example.

Laue, E. G.↗

Braille Reading Systems

Two proposed electromechanical systems for making braille characters produced relatively inexpensively. Similar in operating principle to dotmatrix printers, two methods use electronically actuated pins to reproduce characters from information stored on magnetic tape. First, one or more pins scanned over blank page and energized at intervals to emboss text on paper, one or more dots at time. Second, handheld device containing one or more character-generator cells used by reader to scan lines of text manually.

Garner, H. D.↗

Development and flight test of a helicopter compact, portable, precision landing system concept

An airborne, radar based, precision approach concept is being developed and flight tested as a part of NASA's Rotorcraft All-Weather Operations Research Program. A transponder based beacon landing system (BLS) applying state of the art X band radar technology and digital processing techniques, has been built and is being flight tested to demonstrate the concept feasibility. The BLS airborne hardware consists of an add on microprocessor, installed in conjunction with the aircraft weather/mapping radar, which analyzes the radar beacon receiver returns and determines range, localizer deviation, and glide slope derivation. The ground station is an inexpensive, portable unit which can be quickly deployed at a landing site. Results from the flight test program show that the BLS concept has a significant potential for providing rotorcraft with low cost, precision instrument approach capability in remote areas.

Bull, J. S.↗

Ground-based Measurements of Mesosphere Temperatures by Optical Means

The determination of the rotatinal temperature of the molecular emissions of OH or O2 offers a means of observing from the ground the mesosphere temperature at about 90 km throughout the night. The techniques and optical instrumentation developed to carry out these measurements are described. In comparison with other methods for the observation of this important geophysical quantity the optical technique is inexpensive and readily applicable for automatic operations over a long time period.

Meriweather, J. W., Jr.↗

Wind-weighting for sounding rockets with a telemetry system

A system to provide wind data which can be used for wind-weighting sounding rockets is described. The system uses an automatic tracking telemetry antenna and ranging system together with an inexpensive airborne transponder-type radiosonde.

Boykin, F. M.↗

Astrometry of comets using hypersensitized type 2415 film

Kodak Technical Pan Film 2415 should be known to those doing cometary astrometry. It has exceedingly fine resolution (320 lines/mm) and, when properly hypersensitized, it is almost as fast as treated IIIa-J plates and reaches fainter stars. Reciprocity failure with the treated film is practically zero, and the shelf life of treated film sheets is about a month at 2 C stored in a nitrogen atmosphere. This film is readily available in 4 by 5-inch sheets and is inexpensive. The film base is Estar, a plastic chosen for its stability. Over 120 astrometric measures of negatives on this film have shown a median residual error in comet positions of 1.1 seconds, a value that compares favorably with those of most observatories reporting positions.

Everhart, E.↗

Spectral reflectance of carbonate minerals and rocks in the visible and near infrared (0.35 - 2.55 microns) and its applications in carbonate petrology

Reflection spectroscopy in the visible and near infrared (0.35 to 2.55 micron) offers a rapid, inexpensive, nondestructive tool for determining the mineralogy and investigating the minor element chemistry of the hard-to-discriminate carbonate minerals, and can, in one step, provide information previously obtainable only by the combined application of two or more analytical techniques. When light interacts with a mineral certain wavelengths are preferentially absorbed. The number, positions, widths and relative intensities of these absorptions are diagnostic of the mineralogy and chemical composition of the sample. At least seven bands due to vibrations of the carbonate radical occur between 1.60 and 2.55 micron. Positions of these bands vary from one carbonae mineral to another and can be used for mineral identification. Cation mass is the primary factor controlling band position; cation radius plays a secondary role.

Gaffey, S. J.↗

Effects of Weightlessness of Aurelia Ephyra Differentiation and Statolith Synthesis

Aurelia polyps are especially suited for space flight experiments because they are very small (2 to 4 mm), form ephyrae with gravity sensing structures in 6 to 7 days, and can be reared easily and inexpensively in the laboratory. During iodine-induced metamorphosis ephyrae develop in sequential order from the oral to the aboral end of the polyps. Eight sites of gravity receptors (rhopalia) form per ephyra. These structures have sacs of statoliths at their distal end, which are composed of calcium sulfate dihydrate. Only one statolith forms per cell (statocyte) and the cells collect at the distal end of the rhopalia forming statocysts. Rhopalia with statocysts are necessary for the righting reflex of swimming medusae. Using the Aurelia Metamorphosis Test System (Spangenberg, 1984) for the past eight months, the effects of clinostat rotation in the horizontal and verticall planes on the development of ephyrae and the synthesis of their statoliths were investigated.

Dorothy B. Spangenberg↗

Development and flight test of a helicopter, X-band, portable precision landing system concept

A beacon landing system (BLS) is being developed and flight tested as a part of NASA's Rotorcraft All-Weather Operations Research Program. The system is based on state-of-of-the-art X-band radar technology and digital processing techniques. The bLS airborne hardware consists of an X-band receiver and a small micropreocessor, installed in conjunction wht the aircraft instrument landing system (ILS) receiver. The microprocessor analyzes the X-band, BLS pulses and outputs ILS-compatible localizer and glide slope signals. Range information is obtained using an on-board weather/mapping radar in conjunction with the BLS. The ground station is an inexpensive, portable unit; it weighs less than 70 lb and can be quickly deployed at a landing site. Results from the flight-test program show that the BLS has a significant potential for providing rotorcaraft with low-cost, precision instrument approach capability in remote areas.

Davis, T. J.↗

Investigation of semiconductor clad optical waveguides

A variety of techniques have been proposed for fabricating integrated optical devices using semiconductors, lithium niobate, and glasses as waveguides and substrates. The use of glass waveguides and their interaction with thin semiconductor cladding layers was studied. Though the interactions of these multilayer waveguide structures have been analyzed here using glass, they may be applicable to other types of materials as well. The primary reason for using glass is that it provides a simple, inexpensive way to construct waveguides and devices.

Batchman, T. E.↗

A comparison of electronic heterodyne moire deflectometry and electronic heterodyne holographic interferometry for flow measurements

Electronic heterodyne moire deflectometry and electronic heterodyne holographic interferometry are compared as methods for the accurate measurement of refractive index and density change distributions of phase objects. Experimental results are presented to show that the two methods have comparable accuracy for measuring the first derivative of the interferometric fringe shift. The phase object for the measurements is a large crystal of KD*P, whose refractive index distribution can be changed accurately and repeatably for the comparison. Although the refractive index change causes only about one interferometric fringe shift over the entire crystal, the derivative shows considerable detail for the comparison. As electronic phase measurement methods, both methods are very accurate and are intrinsically compatible with computer controlled readout and data processing. Heterodyne moire is relatively inexpensive and has high variable sensitivity. Heterodyne holographic interferometry is better developed, and can be used with poor quality optical access to the experiment.

Decker, A. J.↗

Testing and optimizing MST coaxial collinear arrays, part 6.4A

Many clear-air VHF wind profiles use coaxial collinear (COCO) arrays for their antenna. A COCO array is composed of long lines of half-wave dipoles spaced one-half wavelength apart. An inexpensive method of checking a COCO array is described and its performance is optimized by measuring and then correcting the relative rf phase among its lines at their feed point. This method also gives an estimate of the rf current amplitude among the lines. The strength and location of the sidelobes in the H-plane of the array can be estimated.

Warnock, J. M.↗

Mini and super mini arrays for the study of highest energy cosmic rays

The chief difficulty in studying the highest energy cosmic rays is the extremely low intensity, only approximately 5 particles per sq km sr century above 10 to the 20th power eV. Instead of attacking the problem by assembling all of the available resources in one place, as has been done in the past, a way that the task can be performed at much less cost per unit sensitive area is suggested, by using numerous inexpensive mini arrays operating independently of each other. In addition to the quantities usually observed, each mini array will record shower particle arrival time distributions. At 10 to the 20th power eV the saving in cost per primary particle is estimated to be a factor of 10 or better, compared to methods now in use, even for mini arrays newly built from scratch for just this purpose.

Linsley, J.↗

Methods for roof-top mini-arrays

To test the idea of the Linsley effect mini array for the study of giant air showers, it is desirable to have a trigger that exploits the effect itself. In addition to the trigger, it is necessary to have a method for measuring the relative arrival times of the particle swarm selected by the trigger. Since the idea of mini arrays is likely to appeal to small research groups, it is desirable to try to design relatively simple and inexpensive methods, and methods that utilize existing detectors. Clusters of small detectors have been designed for operation in the local particle density realm where the probability of or = 2 particles per detector is small. Consequently, this method can discriminate pulses from each detector and thenceforth deal mainly with logic pulses.

Hazen, W. E.↗

Electronic detection of ultra-heavy nuclei by pyroelectric materials

A recent prediction by the authors that pyroelectric materials may be capable of detecting ultra-heavy nuclei has been confirmed. Charge pulse signals from pyroelectric crystals of lithium tantalate exposed to Au ions and a pulsed beam of Ni-58 ions, and from pyroelectric films of polyvinylidene fluoride exposed to a pulsed beam of Ni-58 ions, have been measured using pulse electronics with time constants in the microsecond range. These studies show that pyroelectric materials, in general, are capable of detecting incident nuclei having very high mass and charge. In particular, pyroelectric polymers, such as polyvinylidene fluoride, are readily available as inexpensive flexible films. This new class of charged particle detector could eventually find applications in large-area experiments for detection and trajectory determination of low-energy, ultra-heavy nuclei.

Simpson, J. A.↗

Estimating the weight of generally configured dual wing systems

Formulas available for the weight estimation of monoplane wings cannot be said to be appropriate for the estimation of generally configured dual wing systems. In the present paper a method is described which simultaneously generates a structural weight estimate and a fully stressed, quasi-optimal structure for a model of a dual wing system. The method is fast and inexpensive. It is ideally suited to preliminary design. To illustrate the method, a dual wing system and a conventional wing system are sized. Numerical computation is shown to be suitably fast for both cases and, for both cases, convergence to a final configuration is shown to be quite rapid. To illustrate the validity of the method, a conventional wing is sized and its weight obtained by the present method is compared to its weight determined by a reputable weight estimation formula. The results are shown to be very close.

Cronin, D. L.↗

Buckling of a sublaminate in a quasi-isotropic composite laminate

The buckling of an elliptic delamination embedded near the surface of a thick quasi-isotropic laminate was predicted. The thickness of the delaminated ply group (the sublaminate) was assumed to be small compared to the total laminate thickness. Finite-element and Rayleigh-Ritz methods were used for the analyses. The Rayleigh-Ritz method was found to be simple, inexpensive, and accurate, except for highly anisotropic delaminated regions. Effects of delamination shape and orientation, material anisotropy, and layup on buckling strains were examined. Results show that: (1) the stress state around the delaminated region is biaxial, which may lead to buckling when the laminate is loaded in tension; (2) buckling strains for multi-directional fiber sublaminates generally are bounded by those for the 0 deg and 90 deg unidirectional sublaminates; and (3) the direction of elongation of the sublaminate that has the lowest buckling strain correlates with the delamination growth direction.

Shivakumar, K. N.↗

VLBI collimation-tower technique for time-delay studies of a large ground-station communications antenna

A need for an accurate but inexpensive method for measuring and evaluating time delays of large ground antennas for VLBI applications motivated the development of the collimation tower technique. Supporting analytical work which was performed primarily to verify time delay measurement results obtained for a large antenna when the transmitter was at a collimation distance of 1/25 of the usual far field criterion is discussed. Comparisons of theoretical and experimental results are also given.

Otoshi, T. Y.↗