Search NASA⌕ Search

SEARCH · Search NASA

Results for “intent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Meeting Residential Ventilation Standards Through Dynamic Control of Ventilation Systems

Existing ventilation standards, including American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE) Standard 62.2, specify continuous operation of a defined mechanical ventilation system to provide minimum ventilation, with time-based intermittent operation as an option. This requirement ignores several factors and concerns including: other equipment such as household exhaust fans that might incidentally provide ventilation, negative impacts of ventilation when outdoor pollutant levels are high, the importance of minimizing energy use particularly during times of peak electricity demand, and how the energy used to condition air as part of ventilation system operation changes with outdoor conditions. Dynamic control of ventilation systems can provide ventilation equivalent to or better than what is required by standards while minimizing energy costs and can also add value by shifting load during peak times and reducing intake of outdoor air contaminants. This article describes the logic that enables dynamic control of whole-house ventilation systems to meet the intent of ventilation standards and demonstrates the dynamic ventilation system control concept through simulations and field tests of the Residential Integrated Ventilation-Energy Controller (RIVEC).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative study of control strategies for hybrid GSHP system in the cooling dominated climate

The ground source heat pump (GSHP) system is one of the most energy efficient HVAC technologies in the current market. However, the heat imbalance may degrade the ability of the ground loop heat exchanger (GLHX) to absorb or reject heat. The hybrid GSHP system, which combines a geothermal well field with a supplemental boiler or cooling tower, can balance the loads imposed on the ground loop heat exchangers to minimize its size while retaining superior energy efficiency. This paper presents a recent simulation-based study with an intention to compare multiple common control strategies used in hybrid GSHP systems, including fixed setpoint, outside air reset, load reset, and wetbulb reset. A small office in Oklahoma City conditioned by a hybrid GSHP system was simulated with the latest version of eQUEST 3.7 [1]. In the end, the simulation results reveal that the hybrid GSHP system has the excellent capability to meet the cooling and heating setpoints during the occupied hours, balance thermal loads on the ground loop, as well as improve the thermal comfort of the occupants with the reduced size well field.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A thorough assessment of China’s standard for energy consumption of buildings

China's Design Standard for Energy Efficiency of Public Buildings (the Design Standard) is widely used in the design phase to regulate the energy efficiency of physical assets (envelope, lighting, HVAC) in buildings. However, the standard does not consider many important factors that influence the actual energy use in buildings, and this can lead to gaps between the design estimates and actual energy consumption. To achieve the national energy savings targets defined in the strategic 12th Five-Year Plan, China developed the first standard for energy consumption of buildings GB/T51161-2016 (the Consumption Standard). This study provides an overview of the Consumption Standard, identifies its strengths and weaknesses, and recommends future improvements. The analysis and discussion of the constraint value and the leading value, two key indicators of the energy use intensity, provide insight into the intent and effectiveness of the Consumption Standard. The results indicated that consistency between China's Design Standard GB 50189-2015 and the Consumption Standard GB/T51161-2016 could be achieved if the Design Standard used the actual building operations and occupant behavior in calculating the energy use in Chinese buildings. The development of an outcome-based code in the U.S. was discussed in comparison with China's Consumption Standard, and this revealed the strengths and challenges associated with implementing a new compliance method based on actual energy use in buildings in the U.S. Overall, this study provides important insights into the latest developments of actual consumption-based building energy standards, and this information should be valuable to building designers and energy policy makers in China and the U.S.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Cornell’s future geothermal district heating performance through systems engineering and simulation

Cornell University’s intention to lower its carbon footprint has motivated this engineering evaluation of using low-temperature geothermal energy to supply heat to the campus district energy system. Optimal selection and operation of heat pumps can significantly improve system performance. To support this analysis, we model the quantitative relationships between heat pump configurations and source flow, supply and distribution temperatures, facility heating design options, output heat generation, and carbon abatement outcomes. A systems approach is used for analysis, troubleshooting, and improvement of the model. The result of this effort is a dynamic tool that appropriately responds to hourly thermal demand and communicates energy response for techno-economic analysis. Simulations indicate that a single well-pair in the local Basement Contact Zone reservoir can satisfy almost 68% of annual thermal demand at nearly 20 MWth average capacity while remaining financially competitive compared to conventional heating with levelized cost of heating (LCOH) as low as $4.55/MMBTU ($15.53/MWh th ). A direct-use scheme with heat pump augmentation provided more carbon abatement and 50 to 150% more annual heat supply than one without augmentation. Exploration of three and four well-pair scenarios prove the capability to achieve 50 MW th baseload heating capacity with competitive LCOH and significant carbon reductions.

15 GEOTHERMAL ENERGY↗

Inverse reinforcement learning control for building energy management

Reinforcement learning (RL) based control is widely considered a promising approach in building automation and control as it has demonstrated the potential to deal with complex objectives in adjacent domains like robotics, autonomous vehicles, gaming applications, and advertisement recommendations. When applied to any environment, model-free RL learns to improve its control performance over time without requiring a control model, by receiving and then analyzing feedback from the building environment after each control action. Operational objectives are becoming increasingly complex through the simultaneous consideration of thermal comfort, carbon emissions, grid services, and indoor air quality. In this context, conventional rule-based control approaches are proving sub-optimal, mostly heuristic, and inadequate. The model-free and self learning nature of RL appears promising and attractive as it may address the scalability issues associated with advanced control approaches. However, it suffers from long training times and unstable control behavior during the early stages of its learning process, which makes it unsuitable to be applied directly to buildings. This paper addresses these issues using an inverse reinforcement learning approach (IRL), a technique utilized to learn the objective of a controller agent which is considered an expert in its respective domain. Here, we consider a rule-based control as the expert demonstrator. IRL is different from a direct imitation (i.e., direct mapping of states to actions) of control actions as it tries to find the underlying intent of an expert's policy, providing the controller with a better-generalized policy for unseen states or environments with slightly different dynamics. This approach propels the RL controller's policy to levels similar to or better than that of a rule-based policy before it starts learning by interacting with the building. This makes RL for building energy management applications more practical as it prevents the erratic and exploratory behavior in the initial training period, simultaneously speeding up the learning process when compared to applying an untrained RL agent directly to a building environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mismatch losses in a PV system due to shortened strings

Numerous events may require intentional removal of one or more photovoltaic modules from a string, shortening the length of the string relative to others within the array, resulting in a string length mismatch. The impact of such a mismatch is not well understood either in measurable operational effects (voltage, current, power) or in the potential effects on long-term module health. It is impractical to solely approach this problem experimentally due to the size and complexity of arrays that may experience string length shortening. Here this work presents simulations, validated through limited field experiments on a two string array, providing a basis from which more complex arrays and scenarios may be explored. Refinement of the simulation achieves an overall error in IMPP for the nominal (S 1 ) and test strings (S 2 ) between the simulation and experimental values, through all test conditions, of +0.35 ± 1.46% and -0.36 ± 1.58% respectively. Shortening one of two strings by one module results in a power loss greater than the power contribution of the module alone (1.29 module equivalents); the impact increases through the maximum test case of a six module mismatch with a power loss equivalent to more than 11 modules. The impact of using string-end blocking diodes is presented with an emphasis at the array maximum power point and at open circuit. Implications are discussed for arrays of higher complexity.

14 SOLAR ENERGY↗

Using Willingness to Pay to Forecast the Adoption of Solar Photovoltaics: A ''Parameterization + Calibration'' Approach

Distributed energy resources, such as rooftop solar photovoltaics (PV), are likely to comprise a substantial fraction of new generation capacity in the United States. However, forecasting technology adoption based on people's willingness to pay (WTP) faces two major challenges: the stated-intention and omitted-variable biases. Previous solar adoption literature has neglected to address these two biases altogether. Here, we adopt a 'parameterization + calibration' approach to address both biases and estimate customers' WTP for PV. After collecting survey data on respondents' WTP for adopting PV, we characterize its empirical cumulative density function using a gamma distribution. We further calibrate the gamma distribution parameters using a national distributed PV adoption simulation model, finding the parameters that produce the best fit between simulated and historic solar adoption. We then show that the calibrated gamma distribution improves the raw WTP data after correcting for the two biases. Finally, we use our optimally-calibrated WTP to forecast market demand for residential PV at the county-level of the United States in 2020. Improving estimates of customer willingness to pay has significant implications for policy directly, e.g. estimating the effect of a proposed policy on technology adoption, and other regulatory processes that use forecasting, e.g. integrated resource planning.

14 SOLAR ENERGY↗

Survey on the micro-pollutants presence in surface water system of northern Serbia and environmental and health risk assessment

Highlights: • First survey on the occurrence of 940 substances in the middle part of the Danube Basin. • Micro-pollutants from canals water had higher abundance of contaminants that from river. • High level of sterols indicated dominant effect of untreated domestic wastewater. • Correlations among the groups of micro-pollutants indicated their common origin. • Ecological risk suggesting a potential for adverse effects on fish. This study demonstrates the occurrence of 940 organic micro-pollutants in surface water of four rivers, one irrigation canal system, and two lakes in Vojvodina Province, the northern part of Serbia, summing in total eighteen samples. The number of detected chemicals ranged from 22 to 84, with 127 micro-pollutants detected at least once, representing 13% of the studied substances. The targeted compounds include n-alkanes, sterols, polycyclic aromatic hydrocarbons (PAHs), organochlorine pesticides polychlorinated biphenyls, pesticides, pharmaceutical active compounds, industrial chemicals, plasticizers, etc. Among the analysed compounds, sterols were the most dominant with maximum quantified concentrations. The substances which were quantified with frequency over 50% were two PAHs (2-methylnaphthalene, benzo(ghi)perylene), five sterols (cholesterol, cholestanol, stigmasterol, fucosterol, beta-sitosterol), three pharmaceuticals and personal care products (L-menthol, diethyltoluamide, caffeine), and ten household chemicals (4-tert-octylphenol, dimethyl phthalate, methyl palmitate, phenylethyl alcohol, 1-nonanol, alpha-terpineol, 2-phenoxy-ethanol, methyl myristate, acetophenone, and 2-ethyl-1-hexanol). The list of priority substances under the European Union Directive 2013/39/EU includes 49 priority substances (PSs) out of which 34 were analysed. Among these, eleven PSs were quantified, and only two compounds (fluoranthene and benzo (a) pyrene) exceeded EU Environmental Quality Standards targeted values. The obtained results were compared with the previously published data that dealt with the same targeted number of micro-pollutants in sediment samples. This revealed connections between the same sampling locations. Environmental risk assessment showed the existence of potential ecological risk as 72% of the obtained values for the ecological hazard index (HI) at investigated locations were higher that the targeted value (HI > 1). Estimated values for hazard quotient (HQ) and hazard index (HI) for non-carcinogenic risk were lower than the targeted value, indicating no non-carcinogenic risk through dermal contact and non-intentional ingestion of water. Estimated values for cancer risk were all below 1 × 10{sup −6}, which is not considered to pose significant human health risk.

54 ENVIRONMENTAL SCIENCES↗

Energy ideals, visions, narratives, and rhetoric: Examining sociotechnical imaginaries theory and methodology in energy research

Sociotechnical imaginaries emerged in the last decade as a potentially fruitful approach to understanding how collective social values inflect on the production of scientific knowledge and the design of technological systems. Yet insights generated to date have focused on the categories experts use to define a society’s idealized organization, either as the direct subject of analysis by documentary analysis or through the ways such categories circumscribe the field of authorized “values” open for adjudication in public engagement events. We argue that sociotechnical imaginaries require a new methodological framework for designing research in order to examine the collective values of citizens as they live their daily lives, rather than focusing on experts and the state in order to understand the shared moral, material, and scientific goals of a society. Drawing inspiration from rhetoric, corpus linguistics, and dialectology, we present the Social Energy Atlas, a new and burgeoning research project that employs such methods for studying emergent narrative patterns and variation at the local level. Furthermore, advancing the theory and practice of studying sociotechnical imaginaries is of tremendous benefit to Energy and Social Science researchers, and it is our intent this commentary encourages further careful development and use of the concept.

14 SOLAR ENERGY↗

Suspending democratic (dis)belief: Nonliberal energy polities of solar power in Morocco and Tanzania

This paper proposes the concept of technodemocratic imaginaries (TDIMs) to supplement the widely-used framework of sociotechnical imaginaries (STIMs) for analyzing nonliberal political contexts in energy social science research. Taking the power of coproductionist analysis of STIMs seriously, TDIMs highlight the inherent instabilities within overarching STIMs by arguing that not only are particular groups marginalized and excluded but that they continue to practice and mobilize their own imaginaries of collective governance and justice vis-à-vis energy systems. In contrast, the existing idea of contested STIMs, in which a shared mode of knowledge politics undergirds different imaginaries, casts aside subaltern modes of political engagement and knowledge-making. TDIMs expand conceptions of democracy to include shared practices of credibility in nonliberal political orders. The intent is not to promote democratic relativism but rather to ask scholars and international energy-access practitioners to suspend their democratic disbelief when studying energy matters in so-called nonliberal contexts. We develop the concept of TDIMs by comparing two African nation-states–Morocco and Tanzania–to show how the states and subaltern groups do (or do not) develop TDIMs related to solar power. While international governance organizations often portray Morocco as authoritarian and Tanzania corrupt, each state differently experienced colonization and decolonization and practices different relationships with domestic subaltern groups. Whereas low-income citizens and indigenous groups seek integration into the Moroccan state’s STIM, the Maasai in Tanzania chart their own TDIM separate from the state and international development groups.

14 SOLAR ENERGY↗

Scaffolding civic infrastructures: Examining the role of civic technoscience in public engagements with oil and gas pipelines

Oil and gas pipelines bring attention to the importance of public participation in the management of large-scale infrastructure projects. Participation transforms how communities understand benefits and risks, and can result in safer and more resilient projects. However, participation can be hindered by procedural injustices in planning processes and lack of industry transparency. Based on a survey of 103 civil society groups conducted in 2021, this paper investigates how groups mobilize technical projects and expert knowledge to overcome these. We frame these mobilizations as expressions of civic technoscience, and argue their pivotal role in building capacity for effective engagements with pipelines. To this extent, we furthermore suggest that civic technoscience is fundamental to building civic infrastructures for reforming participatory governance gaps. We conclude with recommendations for how civic technoscience can better support the intentions of civic infrastructuring by coordinating activities across coalitions, as well as by shifting the scales at which groups engage with the governance of pipelines.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Hydrodynamics and energy consumption studies in a three-phase liquid circulating three-phase fluid bed contactor

The hydrodynamics and energy consumption have been studied in a cold flow, bubbling and turbulent, pressurized gas-liquid-solid three-phase fluidized bed (0.15 m ID x 1 m height) with concurrent gas-liquid up flow is proposed with the intention of increasing the gas hold up. The hydrodynamic behaviour is described and characterised by some specific gas and liquid velocities. Particles are easily fluidized and can be uniformly distributed over the whole height of the column. The effect of parameters like liquid flow rate, gas flow rate, particle loading, particle size, and solid density on gas hold up and effect of gas flow rate, solid density and particle size on solid hold up, energy consumption and minimum fluidization velocity has been studied. At the elevated pressures a superior method for better prediction of minimum fluidization velocity and terminal settling velocities has been adopted. The results have been interpreted with Bernoulli's theorem and Richardson-Zaki equation. Based on the assumption of the gas and liquid as a pretend fluid, a simplification has been made to predict the particle terminal settling velocities. The Richardson-Zaki parameter n' was compared with Renzo's results. A correlation has been proposed with the experimental results for the three-phase fluidization. (author)

42 ENGINEERING↗

Desensitizing ignition of energetic materials when exposed to accidental fire

Composite energetic materials combine fuel and oxidizers for high energy density exothermic reactions and are used for ordnance, industrial and localized power generation applications. This study focuses on examining an additive to a mixture of aluminum (Al) and copper oxide (CuO) to decrease ignition sensitivity under accidental fire exposure conditions. Ammonium nitrate (AN) was incorporated into Al+CuO, as a 1:1 replacement for CuO, for varied equivalence ratios and examined for ignition and combustion when exposed to slow and fast heating rate ignition conditions. The goal was to develop an Al+CuO+AN formulation that would perform comparable to Al+CuO when intentionally ignited, but would not ignite in an accidental fire. Experimental results show that Al+CuO+AN with an equivalence ratio (ER) ranging from 4.0–5.5 inerts the reactants when exposed to slow heating conditions, yet ignites with comparative combustion performance to the baseline Al+CuO mixture when exposed to fast heating conditions. These results are consistent with thermochemical simulations of the heat of combustion and adiabatic flame temperature for the respective reactions. In conclusion, this study presents a new approach for tailoring composite energetic materials toward accidental fire safety by exploiting the early stage decomposition kinetics of AN, which are activated only by slow heating ignition conditions.

36 MATERIALS SCIENCE↗

Demonstration of low-level biogenic fuel content using quench curve and direct liquid scintillation counting (LSC) methods

In this work, an investigation into the direct method for liquid scintillation counting (LSC) quantification of biogenic fuel content in fuel blendstock is presented. This method development intentionally used a colored matrix (~99 wt%), fossil diesel fraction, and low-level biogenic fractions (~1 wt%) to determine the applicability of the LSC technique in colored blend mixtures. LSC procedures for quench correction, including the use of an instrument internal standard (Quantulus SQP values), color quench curves, and an internal 14 C standard spike on samples containing low-level amounts of biogenic gasoline, jet, and diesel mixed with fossil fuel, were compared. Samples were analyzed on both Perkin-Elmer Quantulus and Tri-Carb instruments, and the 14 C contents were compared with those determined by accelerator mass spectrometry (AMS). Results from the Tri-Carb instrument showed that percent differences of <10 % compared to AMS-reported values are achievable at 5-hour count times despite colored samples. A comparison between the impact of chemical and color quenching in the fuel samples showed that color quenching in highly colored samples reduces efficiency significantly more than chemical quenching, indicating that chemical quench curves are not appropriate for highly colored biofuel/fossil-fuel blended samples. Results indicate that both the direct method with internal spike quench correction and the use of a color-quench curve provide accurate results for 1 % biogenic fuel blends. Additionally, we have explored the use of Fourier transform infrared (FTIR) spectroscopy in measuring the biogenic content of the colored blended fuel samples. Preliminary results show the presence of biogenic carbon-derived fingerprints that are absent in fossil-derived sample. However, further work is needed to develop an FTIR-based quantitative method.

09 BIOMASS FUELS↗

Limiter-aware adaptive excitation control for hydropower generators with legacy voltage regulation systems

Hydropower units often rely on legacy excitation systems with fixed automatic voltage regulator (AVR) settings, but parameter drift, changing operating conditions, and evolving grid-service demands can degrade terminal-voltage regulation over time. This problem should be addressed because poor voltage regulation affects reactive-power support, system stability, and reliable plant operation, and replacing installed AVR and limiter logic is costly and disruptive in practice. To address this issue, this paper proposes a retrofit-friendly enhancement for hydropower generator excitation systems that combines adaptive tuning of the AVR middle lead–lag branch with a small proportional-integral correction for removing steady bias and slow drift. The adaptive laws are normalized, projection-bounded, and equipped with leakage, while adaptation is enabled only in the middle branch. Thus, the intent of the underexcitation and overexcitation limiters, as well as legacy current and rate limits, remains unchanged. Stability is analyzed under incremental performance assumptions, yielding boundedness and asymptotic tracking in the absence of saturation. The method is evaluated using real operational data from a utility-scale hydropower unit at Rocky Reach Dam, Unit C-8. Compared with the fixed AVR baseline, the proposed method reduces terminal-voltage mean squared error by about 70%, removes long periods of steady-state bias, and improves transient tracking while coexisting with limiter actions. These results show that substantial voltage-control improvement can be achieved on existing hydropower units with minimal integration effort and without replacing the installed AVR structure.

ESST5B model↗

Risk matrix for legacy wells within the Area of Review (AoR) of Carbon Capture & Storage (CCS) projects

The success of CCS depends on the capacity, injectivity, and confinement by the storage medium. Thousands of wells drilled over the past century with the intention to find the trapped oil and gas may penetrate the containment seals. These wells may provide leakage pathways for the CO 2 to escape and contaminate the underground sources of drinking water (USDW) or reach the surface in the worst-case scenario. Identifying the risky wells penetrating the containment seals and predicting their current as well as future well integrity is the most challenging task when limited data is available. Here, this paper proposes a unique methodology for risk assessment of the wells penetrating the containment seals based on the proximity of these wells from the proposed injection location, mechanical integrity, and accessibility of these wells over the lifecycle of the CCS project. This helps in identifying the wells which need immediate attention from the wells that need little to no attention. It also highlights the corrective actions necessary for the success of the CCS project as well as help estimate the approximate cost required to perform the corrective actions. This methodology focuses on all wells (producers, injectors, orphan, abandoned, water, stratigraphic, etc) while the majority of the studies found in literature focused on wells with sustained casing pressure (SCP) reports and cement bond logs (CBL). The proposed risk matrix, if applied to future CCS projects across the globe, will uniformly categorize the wells within the Area of Review (AoR).

58 GEOSCIENCES↗

Electrochemical investigation of stainless steel corrosion in a proton exchange membrane electrolyzer cell

The lack of a fundamental understanding of the corrosion mechanisms in the electrochemical environments of proton exchange membrane (PEM) electrolyzer and/or fuel cells (ECs/FCs) has seriously hindered the improvement of performance and efficiency of PEM ECs/FCs. In this study, a stainless steel mesh was purposely used as an anode gas diffusion layer that was intentionally operated with high positive potentials under harsh oxidative environments in a PEMEC to study the corrosion mechanism of metal migration. A significant amount of iron and nickel cations were determined to transport through the anode catalyst layer, the PEM and the cathode catalyst layer during the PEMEC operation. The formation/deposition of iron oxide and nickel oxide on the carbon paper gas diffusion layer at the cathode side is first revealed by both scanning electron microscope and X-ray diffraction. The results indicate the corrosion elements of iron and nickel are transported from anode to cathode through the catalyst-coated membrane, and deposited on carbon fibers as oxides. This phenomenon could also open a new corrosion-based processing approach to potentially fabricate multifunctional oxide structures on carbon fiber devices. This study has demonstrated a new accelerated test method for investigating the corrosion and durability of metallic materials as well.

08 HYDROGEN↗

Dynamic oxidation of (Mn,Co) 3 O 4 -Coated interconnects for solid oxide electrolysis cells

Solid oxide electrolysis cell stacks are expected to experience dynamic conditions when using renewable electricity derived from wind or solar power. To address this scenario, (Mn,Co) 3 O 4 (MCO)-coated Crofer 22 APU interconnect coupons are subjected to thermal cycling, and intermittent current density, with gas compositions relevant to high-temperature electrolysis (elevated steam:hydrogen ratio and oxygen content). Defects are also intentionally introduced in the MCO coating, to assess whether the difference in oxidation properties of the adjacent coated and uncoated (defective) surfaces causes sufficient stress to damage the protective oxide scale. Specimens with defects are subjected to oxidation for 1000 h at 800 °C, or thermal cycling. Before thermal cycling, some specimens are pre-oxidized to create a thick oxide scale to mimic the scale thickness expected after ~30 kh operation. In all cases, the coating and oxide scale remain well adhered with no cracking observed. Area-specific resistance (ASR) is monitored in both single-atmosphere and dual-atmosphere conditions, and the ASR is stable and is not impacted by dynamic cycling of the current density. Finally, this work provides confidence that the MCO coated interconnect will function as needed in dynamic operation conditions, even with coating defects.

08 HYDROGEN↗