Search NASA⌕ Search

SEARCH · Search NASA

Results for “ionization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Two-photon double ionization with finite pulses: Application of the virtual sequential model to helium

As a step toward the full ab initio description of two-photon double ionization processes, we present a finite-pulse version of the virtual-sequential model for polyelectronic atoms. The model relies on the ab initio description of the single ionization scattering states of both the neutral and ionized target system. As a proof of principle and a benchmark, the model is applied to the helium atom using the newstock atomic photoionization code. The results of angularly integrated observables, which are in excellent agreement with existing time-dependent Schrödinger equation (TDSE) simulations, show how the model is able to capture the role of electron correlation in the nonsequential regime, and the influence of autoionizing states in the sequential regime, at a comparatively modest computational cost. The model also reproduces the two-particle interference with ultrashort pulses, which is within reach of current experimental technologies. Furthermore, the model shows the modulation of the joint energy distribution in the vicinity of autoionizing states, which can be probed with extreme-ultraviolet pulses of duration much longer than the characteristic lifetime of the resonance. Furthermore, the formalism discussed here applies also to polyelectronic atoms and molecules, thus opening a window on nonsequential and sequential double ionization in these more complex systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

Two-electron interference in two-photon attosecond double ionization of neon

The pump-probe experiments enabled by x-ray free-electron lasers (XFEL) will allow us to directly observe correlated electronic motion with attosecond time resolution by detecting photoelectron pairs in coincidence. In helium, the transition between the nonsequential and sequential regime in two-photon double ionization (TPDI) is well explained by a virtual-sequential model. Much less is known, however, about the TPDI process in more complex atoms. Recently, we extended the virtual-sequential model to arbitrary light pulses [Chattopadhyay Phys. Rev. A 108, 013114 (2023)]. This extension employs multichannel scattering states for the single ionization of both the neutral and the ionized target, which we initially applied to helium. In the present study, we show that our extended virtual-sequential model reproduces the qualitative features of the angularly integrated observables with available experimental results for neon, a considerably more complex target. We observe an intriguing feature of inverted two-particle interference in the joint-energy distribution of Ne compared to He. Finally, this phenomenon, attributable to the presence of a final doubly ionized state with triplet symmetry coupled to the two photoelectrons, should be observable with current experimental technologies.

74 ATOMIC AND MOLECULAR PHYSICS↗

Nonlinear time-dependent density-functional-theory study of ionization and harmonic generation in CO{sub 2} by ultrashort intense laser pulses: Orientational effects

Time-dependent density-functional-theory (TDDFT) methods are used to calculate the orientational dependence of ionization and molecular high-order harmonic generation (MHOHG) in the CO{sub 2} molecule as a function of laser intensity I{sub 0{>=}}10{sup 14} W/cm{sup 2} for few-cycle 800 nm laser pulses. A time-series analysis is used to confirm the recollision model in MHOHG for different density potentials. It is found that at intensities I{sub 0}>3.5x10{sup 14} W/cm{sup 2}, lower highest occupied molecular orbitals (HOMO's) contribute significantly to ionization and to the MHOHG process. This is due to the symmetry of these orbitals. Even though such lower orbitals have higher ionization potentials (IP), ionization and MHOHG processes occur when orbital densities are maximum with laser polarization direction.

74 ATOMIC AND MOLECULAR PHYSICS↗

Ionization dynamics via ion-collection field of Rydberg atoms approaching metal surfaces

The ionization dynamics of slow hydrogenlike Rydberg atoms (principal quantum number n>>1) approaching solid surfaces is considered via an ion-collection electric field, using an appropriate etalon equation method. The complex energy eigenvalue problem is solved in the critical region R{approx_equal}R{sub c{approx_equal}}R{sub c}{sup I} of the ion-surface distances R in which the ionization process is mainly localized and the parabolic symmetry is preserved. The relatively simple analytical forms for the parabolic rates enable us to elucidate the main features of the self-consistent ionization dynamics of the projectiles with the time-dependent charges. The ionization distances R{sub c}{sup I} are calculated and an agreement of the averaged probability (for the atomic beam) with the corresponding experimental results is discussed for the relevant parameters of the ion-surface system. The formulas are suggested for the simulation of the experimental signal and for deducing the R{sub c}{sup I} values from this signal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Theoretical study of photoelectron angular distributions in single-photon ionization of aligned N{sub 2} and CO{sub 2}

We calculate photoelectron angular distributions (PADs) resulting from single-photon (43 eV) ionization of molecules that have been transiently aligned with a short laser pulse. The total ionization cross sections of N{sub 2} and CO{sub 2} vs the time delay between the aligning laser pulse and the soft x-ray photon are calculated and compared to experimental results reported by I. Thomann et al. [J. Phys. Chem. A 112, 9382 (2008)]. We present the PADs from these aligned molecules in the laboratory frame which can be compared directly with future experiments from aligned N{sub 2} and CO{sub 2}. The alignment dependence of single-photon ionization, multiphoton ionization, and high-order harmonic generation are also analyzed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Determination of the first ionization potential of technetium

The first ionization potential (IP) of technetium (Tc) has been determined by evaluating Rydberg convergences toward the first ionization potential as well as toward two low-lying excited states of the singly charged Tc ion. The Rydberg states were excited and detected by applying multiphoton resonance ionization mass spectrometry (RIMS) on the long-lived isotope {sup 99g}Tc using a three-color excitation scheme. The observed Rydberg convergences yield a result for the first ionization potential of Tc V{sub IP}(Tc)=7.119380(32) eV. This precise value for V{sub IP}(Tc) is somewhat lower than the so far published data of 7.23 eV or 7.28 eV, dating back to the 1950s.

74 ATOMIC AND MOLECULAR PHYSICS↗

Double L{sub 3}M ionization of Pd induced by impact with medium-energy electrons

The electron-induced L{sub 3}M two-step double ionization cross sections of metallic Pd were determined experimentally for incident electron beam energies ranging from the double ionization threshold up to 18 keV. The double L{sub 3}M ionization cross sections were derived from the intensity ratios (I{sub L{alpha}M}:I{sub L{alpha}}) of the resolved M satellites to the parent diagram lines. The sample was bombarded with monoenergetic electrons from an energy-tunable 20-kV electron gun. The diagram and M-satellite x-ray lines were measured by means of high-resolution x-ray spectroscopy, using a reflection-type von Hamos bent crystal spectrometer. The two-step partial cross sections were determined by subtracting from the measured total double ionization cross sections the contributions due to the shake process and L{sub 1}-L{sub 3}M{sub 4,5} Coster-Kronig transitions. Despite the thick target employed in the present study, the dependence of the two-step cross sections on the incoming electron energy could be derived using a target slice decomposition method. It is shown that the obtained energy dependence can be well reproduced by the semiempirical parametrization model of Pattard and Rost.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ionization waves of arbitrary velocity driven by a flying focus

A chirped laser pulse focused by a chromatic lens exhibits a dynamic, or flying, focus in which the trajectory of the peak intensity decouples from the group velocity. In a medium, the flying focus can trigger an ionization front that follows this trajectory. By adjusting the chirp, the ionization front can be made to travel at an arbitrary velocity along the optical axis. For this study, we present analytical calculations and simulations describing the propagation of the flying focus pulse, the self-similar form of its intensity profile, and ionization wave formation. The ability to control the speed of the ionization wave and, in conjunction, mitigate plasma refraction has the potential to advance several laser-based applications, including Raman amplification, photon acceleration, high-order-harmonic generation, and THz generation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Possibility of using cylindrical ionization chambers for percent depth-dose measurements in clinical electron beams

Purpose: This study investigated the possibility of using cylindrical ionization chambers for percent depth-dose (PDD) measurements in high-energy clinical electron beams. Methods: The cavity correction factor, P{sub cav}, for cylindrical chambers with various diameters was calculated as a function of depth from the surface to R{sub 50}, in the energy range of 6-18 MeV electrons with the EGSnrc C ++ -based user-code CAVITY. The results were compared with those for IBA NACP-02 and PTW Roos parallel-plate ionization chambers. The effective point of measurement (EPOM) for the cylindrical chamber and the parallel-plate chamber was positioned according to the IAEA TRS-398 code of practice. The overall correction factor, P{sub Q}, and the percent depth-ionization (PDI) curve for a PTW30013 Farmer-type chamber were also compared with those of NACP-02 and Roos chambers. Results: The P{sub cav} values at depths between the surface and R{sub 50} for cylindrical chambers were all lower than those with parallel-plate chambers. However, the variation in depth for cylindrical chambers equal to or less than 4 mm in diameter was equivalent to or smaller than that for parallel-plate chambers. The P{sub Q} values for the PTW30013 chamber mainly depended on P{sub cav}, and for parallel-plate chambers depended on the wall correction factor, P{sub wall}, rather than P{sub cav}. P{sub Q} at depths from the surface to R{sub 50} for the PTW30013 chamber was consequently a lower value than that with parallel-plate chambers. However, the variation in depth was equivalent to that of parallel-plate chambers at electron energies equal to or greater than 9 MeV. The shift to match calculated PDI curves for the PTW30013 chamber and water (perturbation free) varied from 0.65 to 0 mm between 6 and 18 MeV beams. Similarly, the shifts for NACP-02 and Roos chambers were 0.5-0.6 mm and 0.2-0.3 mm, respectively, and were nearly independent of electron energy. Conclusions: Calculated PDI curves for PTW30013, NACP-02, and Roos chambers agreed well with that of water by using the optimal EPOM. Therefore, the possibility of using cylindrical ionization chambers can be expected for PDD measurements in clinical electron beams.

61 RADIATION PROTECTION AND DOSIMETRY↗

Gauging Metallicity of Diffuse Gas under an Uncertain Ionizing Radiation Field

Gas metallicity is a key quantity used to determine the physical conditions of gaseous clouds in a wide range of astronomical environments, including interstellar and intergalactic space. In particular, considerable effort in circumgalactic medium (CGM) studies focuses on metallicity measurements because gas metallicity serves as a critical discriminator for whether the observed heavy ions in the CGM originate in chemically enriched outflows or in more chemically pristine gas accreted from the intergalactic medium. However, because the gas is ionized, a necessary first step in determining CGM metallicity is to constrain the ionization state of the gas which, in addition to gas density, depends on the ultraviolet background radiation field (UVB). While it is generally acknowledged that both the intensity and spectral slope of the UVB are uncertain, the impact of an uncertain spectral slope has not been properly addressed in the literature. This Letter shows that adopting a different spectral slope can result in an order of magnitude difference in the inferred CGM metallicity. Specifically, a harder UVB spectrum leads to a higher estimated gas metallicity for a given set of observed ionic column densities. Therefore, such systematic uncertainties must be folded into the error budget for metallicity estimates of ionized gas. An initial study shows that empirical diagnostics are available for discriminating between hard and soft ionizing spectra. Applying these diagnostics helps reduce the systematic uncertainties in CGM metallicity estimates.

79 ASTRONOMY AND ASTROPHYSICS↗

Self‐assembling Peptides with Internal Ionizable Unnatural Amino Acids: A General Approach to pH‐responsive Peptide Materials

Self‐assembled peptides are an emerging family of biomaterials that show great promise for a range of biomedical and biotechnological applications. Introducing and tuning the pH‐responsiveness of the assembly is highly desirable for improving their biological activities. Inspired by proteins with internal ionizable residues, we report a simple but effective approach to constructing pH‐responsive peptide assembly containing unnatural ionic amino acids with an aliphatic tertiary amine side chain. Through a combined experimental and computational investigation, we demonstrate that these residues can be accommodated and stabilized within the internal hydrophobic compartment of the peptide assembly. The hydrophobic microenvironment shifts their pK a significantly from a basic pH typically found for free amines to a more biologically relevant pH in the weakly acidic range. The pH‐induced ionization and ionization‐dependent self‐assembly and disassembly are thoroughly investigated and correlated with the biological activity of the assembly. This new approach has unique advantages in tuning the pH‐responsiveness of self‐assembled peptides across a large pH range in a complex biological environment. We anticipate the ionizable amino acids developed here can be widely applicable to the synthesis and self‐assembly of many amphiphilic peptides with endowed pH‐responsive properties to enhance their biological activities toward applications ranging from targeted therapeutic delivery to proton transport.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Utilizing the Inherent Electrolysis in a Chip-Based Nanoelectrospray Emitter System to Facilitate Selective Ionization and Mass Spectrometric Analysis of Metallo Alkylporphyrins

A commercially available chip-based infusion nanoelectrospray ionization system was used to ionize metallo alkylporphyrins for mass spectrometric detection and structure elucidation by mass spectrometry. Different ionic forms of model compounds (nickel (II), vanadyl (II), copper (II) and cobalt (II) octaethylporphyrin) were created by using two different types of conductive pipette tips supplied with the device. These pipette tips provide the conductive contact to solution at which the electrolysis process inherent to electrospray takes places in the device. The original unmodified, bare carbon-impregnated plastic pipette tips, were exploited to intentionally electrochemically oxidize (ionize) the porphyrins to form molecular radical cations for detection. Use of modified pipette tips, with a surface coating devised to inhibit analyte mass transport to the surface, was shown to limit the ionic species observed in the mass spectra of these porphyrins largely, but not exclusively, to the protonated molecule. Under the conditions of these experiments, the effective upper potential limit for oxidation with the uncoated pipette tip was 1.1 V or less and the coated pipette tips effectively prevented the oxidation of analytes with redox potentials greater than about 0.25 V. Product ion spectra of either molecular ionic species could be used to determine the alkyl chain length on the porphyrin macrocycle. The utility of this electrochemical ionization approach for the analysis of naturally occurring samples was demonstrated using nickel geoporphyrin fractions isolated from Gilsonite bitumen. Acquiring neutral loss spectra as a means to improve the specificity of detection in these complex natural samples was also illustrated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calculation of the Ionization Coefficient in the Townsend Discharge in the Mixture of Argon and Mercury Vapors with Temperature-Dependent Composition

For a hybrid model of the low-current discharge considering, along with direct ionization of the mixture components by electrons, the Penning ionization of mercury atoms by metastable argon atoms, the ionization coefficient in the argon–mercury mixture used in illuminating lamps is calculated. The analytical approximation formula describing the dependence of the ionization coefficient of the mixture on the reduced electric field strength and temperature is obtained for sufficiently wide ranges of their variations, and its accuracy is estimated. It is demonstrated that the discharge ignition voltage calculated using this formula is in agreement with the results of simulation and the available experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation and Applications of In-Source Oxidation in Liquid Sampling-Atmospheric Pressure Afterglow Microplasma Ionization (LS-APAG) Source

A liquid sampling-atmospheric pressure afterglow microplasma ionization (LS-APAG) source is presented for the first time, which is embedded with both electrospray ionization (ESI) and atmospheric pressure afterglow microplasma ionization (APAG) techniques. This ion source is capable of analyzing compounds with diverse molecule weights and polarities. An unseparated mixture sample was detected as a proof-of-concept, giving complementary information (both polarities and non-polarities) with the two ionization modes. It should also be noted that molecular mass can be quickly identified by ESI with clean and simple spectra, while the structure can be directly studied using APAG with in-source oxidation. The ionization/oxidation mechanism and applications of the LS-APAG source have been further explored in the analysis of nonpolar alkanes and unsaturated fatty acids/esters. A unique [M + O – 3H]{sup +} was observed in the case of individual alkanes (C{sub 5}–C{sub 19}) and complex hydrocarbons mixture under optimized conditions. Moreover, branched alkanes generated significant in-source fragments, which could be further applied to the discrimination of isomeric alkanes. The technique also facilitates facile determination of double bond positions in unsaturated fatty acids/esters due to diagnostic fragments (the acid/ester-containing aldehyde and acid oxidation products) generated by on-line ozonolysis in APAG mode. Finally, some examples of in situ APAG analysis by gas sampling and surface sampling were given as well. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrospray Ionization with High-Resolution Mass Spectrometry as a Tool for Lignomics: Lignin Mass Spectrum Deconvolution

The capability to characterize lignin, lignocellulose, and their degradation products is essential for the development of new renewable feedstocks. Electrospray ionization high-resolution time-of-flight mass spectrometry (ESI-HR TOF-MS) method was developed expanding the lignomics toolkit while targeting the simultaneous detection of low and high molecular weight (MW) lignin species. The effect of a broad range of electrolytes and various ionization conditions on ion formation and ionization effectiveness was studied using a suite of mono-, di-, and triarene lignin model compounds as well as kraft alkali lignin. Contrary to the previous studies, the positive ionization mode was found to be more effective for methoxy-substituted arenes and polyphenols, i.e., species of a broadly varied MW structurally similar to the native lignin. For the first time, we report an effective formation of multiply charged species of lignin with the subsequent mass spectrum deconvolution in the presence of 100 mmol L{sup −1} formic acid in the positive ESI mode. The developed method enabled the detection of lignin species with an MW between 150 and 9000 Da or higher, depending on the mass analyzer. The obtained M{sub n} and M{sub w} values of 1500 and 2500 Da, respectively, were in good agreement with those determined by gel permeation chromatography. Furthermore, the deconvoluted ESI mass spectrum was similar to that obtained with matrix-assisted laser desorption/ionization (MALDI)-HR TOF-MS, yet featuring a higher signal-to-noise ratio. The formation of multiply charged species was confirmed with ion mobility ESI-HR Q-TOF-MS. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Triboionization: a Novel Ionization Method by Peeling of Cohesive Substances for Mass Spectrometry

A novel ionization/sampling method termed triboionization was developed. Triboionization is an ionization method that only uses cohesive substances, such as food wrap or sticky tape, and does not require an electrode, electric power supply, heat source, light source, radiation, or gas, unlike most other conventional ambient ionization methods. In this study, the sample compound attached to adhesive tape or plastic wrap was quickly peeled off at a distance of approximately 2 cm from the atmospheric interface of a mass spectrometer. All of the five types of food wrap and 13 types of adhesive tape tested successfully ionized caffeine. Nine out of ten model compounds were detected as the corresponding molecular ions in the positive or negative mode by this ionizing contrivance using an oriented polypropylene adhesive tape. The detected molecular ions were typically protonated molecules or sodium adducts in the positive mode or deprotonated molecules in the negative mode. The elemental compositions of the observed ions were confirmed within 5 ppm by high-resolution mass spectrometry. The triboionization phenomenon was considered to depend on physical and electronic events caused by peeling off a cohesive substance. Triboionization is able to provide a compact ion source using only mechanical mechanisms. Additionally, triboionization allows sticky tape to be used as a convenient sampling device for surface analysis. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Amifostine, a radioprotectant agent, protects rat brain tissue lipids against ionizing radiation induced damage: An FTIR microspectroscopic imaging study

Amifostine is the only approved radioprotective agent by FDA for reducing the damaging effects of radiation on healthy tissues. In this study, the protective effect of amifostine against the damaging effects of ionizing radiation on the white matter (WM) and grey matter (GM) regions of the rat brain were investigated at molecular level. Sprague-Dawley rats, which were administered amifostine or not, were whole-body irradiated at a single dose of 800 cGy, decapitated after 24 h and the brain tissues of these rats were analyzed using Fourier transform infrared microspectroscopy (FTIRM). The results revealed that the total lipid content and CH{sub 2} groups of lipids decreased significantly and the carbonyl esters, olefinic=CH and CH{sub 3} groups of lipids increased significantly in the WM and GM after exposure to ionizing radiation, which could be interpreted as a result of lipid peroxidation. These changes were more prominent in the WM of the brain. The administration of amifostine before ionizing radiation inhibited the radiation-induced lipid peroxidation in the brain. In addition, this study indicated that FTIRM provides a novel approach for monitoring ionizing radiation induced-lipid peroxidation and obtaining different molecular ratio images can be used as biomarkers to detect lipid peroxidation in biological systems.

36 MATERIALS SCIENCE↗

The iQID Camera: An Ionizing-Radiation Quantum Imaging Detector

We have developed and tested a novel, ionizing-radiation Quantum Imaging Detector (iQID). This scintillation-based detector was originally developed as a high-resolution gamma-ray imager, called BazookaSPECT, for use in single-photon emission computed tomography (SPECT). Recently, we have investigated the detectors response and imaging potential with other forms of ionizing radiation including alpha, neutron, beta, and fission fragment particles. The detector’s response to a broad range of ionizing radiation has prompted its new title. The principle operation of the iQID camera involves coupling a scintillator to an image intensifier. The scintillation light generated particle interactions is optically amplified by the intensifier and then re-imaged onto a CCD/CMOS camera sensor. The intensifier provides sufficient optical gain that practically any CCD/CMOS camera can be used to image ionizing radiation. Individual particles are identified and their spatial position (to sub-pixel accuracy) and energy are estimated on an event-by-event basis in real time using image analysis algorithms on high-performance graphics processing hardware. Distinguishing features of the iQID camera include portability, large active areas, high sensitivity, and high spatial resolution (tens of microns). Although modest, iQID has energy resolution that is sufficient to discrimate between particles. Additionally, spatial features of individual events can be used for particle discrimination. An important iQID imaging application that has recently been developed is single-particle, real-time digital autoradiography. In conclusion, we present the latest results and discuss potential applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗