Search NASA⌕ Search

SEARCH · Search NASA

Results for “loads analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Relaxations of AC Maximal Load Delivery for Severe Contingency Analysis

This work considers the task of finding an AC-feasible operating point of a severely damaged transmission network while ensuring that a maximal amount of active power loads can be delivered. This AC Maximal Load Delivery (AC-MLD) task is a nonlinear, non-convex optimization problem, and is incredibly challenging to solve on large-scale transmission system datasets. This work demonstrates that convex relaxations of the AC-MLD problem provide a reliable and scalable method for finding high-quality bounds on the amount of active power that can be delivered in the AC-MLD problem. To demonstrate their effectiveness, the solution methods proposed in this work are rigorously evaluated on 1000 N – k scenarios on seven power networks ranging in size from 70 to 6000 buses. Furthermore, the most effective relaxation of the AC-MLD problem converges in less than 20 seconds on commodity computing hardware for all 7000 of the scenarios considered.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transportation Electrification Load Development For A Renewable Future Analysis: Preprint

The transition to electricity as a transportation fuel will create a new load for electricity generation. A set of regional hourly load profiles for electrified vehicles was developed for the 2010 to 2050 timeframe. The transportation electrical energy was determined using regional population forecast data, historical vehicle per capita data, and market penetration growth functions to determinethe number of plug-in electric vehicles (PEVs) in each analysis region. Market saturation scenarios of 30% and 50% of sales of PEVs consuming on average approx. 6 kWh per day were considered. PEV aggregate load profiles from previous work were combined with vehicle population data to generate hourly loads on a regional basis. A transition from consumer-controlled charging towardutility-controlled charging was assumed such that by 2050 approximately 45% of the transportation energy demands could be delivered across four daily time slices under optimal control from the utility?s perspective. This electrified transportation analysis resulted in an estimate for both the flexible load and fixed load shapes on a regional basis that may evolve under two PEV market penetrationscenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fatigue Life Analysis of Tapered Hybrid Composite Flexbeams

Nonlinear-tapered flexbeam laminates from a full-size composite helicopter rotor hub flexbeam were tested under combined constant axial tension and cyclic bending loads. The two different graphite/glass hybrid configurations tested under cyclic loading failed by delamination in the tapered region. A 2-D finite element model was developed which closely approximated the flexbeam geometry, boundary conditions, and loading. The analysis results from two geometrically nonlinear finite element codes, ANSYS and ABAQUS, are presented and compared. Strain energy release rates (G) obtained from the above codes using the virtual crack closure technique (VCCT) at a resin crack location in the flexbeams are presented for both hybrid material types. These results compare well with each other and suggest that the initial delamination growth from the resin crack toward the thick region of the flexbeam is strongly mode II. The peak calculated G values were used with material characterization data to calculate fatigue life curves and compared with test data. A curve relating maximum surface strain to number of loading cycles at delamination onset compared reasonably well with the test results.

Murri, Gretchen B.↗

Analysis of F/A-18 Tail Buffet Data Acquired in the 80- by 120-Foot Wind Tunnel

Tail buffet studies were conducted on a full-scale, production, F/A-18 fighter aircraft in the 80- by 120-Foot Wind Tunnel of the National Full-Scale Aerodynamic Complex at NASA Ames Research Center at Moffett Field, California. Tail buffet data were acquired over an angle-of-attack range of +20 deg to +40 deg, a side-slip range of -16 deg to + 16 deg, and at wind speeds up to 100 knots. The maximum speed corresponds to a Reynolds number of l2.3 x l0(exp 6) based on mean aerodynamic chord and a Mach number of 0. 15. The port, vertical tail fin was instrumented with ninety-six surface-pressure transducers, arranged in six by eight arrays, on each side of the fin. ne aircraft was also equipped with a removable Leading-Edge Extension (LEX) fence whose purpose is to reduce tail-buffet loads. Current analysis methods for the unsteady aerodynamic pressures and loads are described. Only results for the zero side-slip condition are to be presented, both with and without the LEX fence. Results of the time-averaged, power-spectral analysis are presented for the tail fin bending moments which are derived from the integrated pressure field. Local wave velocities on the tail surfaces are calculated from pressure correlations. It was found that the LEX fence significantly reduces the magnitude of the root-mean-square pressures and bending moments. Scaling and repeatability issues are addressed by comparing the present full scale results for pressures at the 60%-span and 45%-chord location with previous full-scale F/A-18 tail-buffet test in the 80- by 120- Foot Wind Tunnel, and with several small-scale tests. The comparisons show that the tail buffet frequency scales very well with tail chord and free-stream velocity, and that there is good agreement with the previous full-scale test. Root-mean-square pressures and power spectra do not scale as well as the frequency results. Addition of a LEX fence caused tail-buffet loads to be reduced at all model scales.

James, Kevin D.↗

Stability of structural rings under uniformly distributed radial loads

Energy method analysis establishes parameters governing stability of circular rings acted upon by constant, uniformly distributed loads. Energy method is used so that nonlinear behavior of structure before buckling can be accounted for. Method affords conceptually superior basis for analyzing the axisymmetric deviation mode.

Williams, H. E.↗

Bending and stretching finite element analysis of anisotropic viscoelastic composite plates

Finite element algorithms have been developed to analyze linear anisotropic viscoelastic plates, with or without holes, subjected to mechanical (bending, tension), temperature, and hygrothermal loadings. The analysis is based on Laplace transforms rather than direct time integrations in order to improve the accuracy of the results and save on extensive computational time and storage. The time dependent displacement fields in the transverse direction for the cross ply and angle ply laminates are calculated and the stacking sequence effects of the laminates are discussed in detail. Creep responses for the plates with or without a circular hole are also studied. The numerical results compare favorably with analytical solutions, i.e. within 1.8 percent for bending and 10(exp -3) 3 percent for tension. The tension results of the present method are compared with those using the direct time integration scheme.

Hilton, Harry H.↗

Charging location selection of an incoming electric vehicle for large EV depot infrastructure

As the use of renewable energy resources increases within charging infrastructures, the risk that charging an additional load within the charging infrastructure will create a violation of the applicable grid code also increases. In an embodiment, a charging location is selected for an incoming load based on a load flow analysis, to thereby mitigate the risk of a violation. This selection process may also account for the charging schedule of the load and the capacity of available charging stations (e.g., fast charging vs. slow charging).

Hafiz, Faeza↗

Bearing-bypass loading in composite joints - Testing and stress analysis

A combined experimental and analytical study of bearing and bypass loading on single-fastener specimens of a 16-ply, quasi-isotropic T300/5208 graphite/epoxy laminate with a centrally located hole is reported. The specimens were loaded in either tension or compression, and onset damage, ultimate strengths, and corresponding failure modes were determined. The tension data showed the expected linear interaction for combined bearing-bypass loading with damage developing in the net-section tension mode. However, the bearing-onset strengths showed an unexpected interaction of the bearing and compressive bypass loads in which the latter reduced the bearing-onset strength. A linear finite element analysis showed that bearing-bypass loading had a marked influence on the bolt-hole contact which in turn had a significant effect on local stresses.

Crews, John H., Jr.↗

Statistical Analysis of Solar PV Power Frequency Spectrum for Optimal Employment of Building Loads

In this paper, a statistical analysis of the frequency spectrum of solar photovoltaic (PV) power output is conducted. This analysis quantifies the frequency content that can be used for purposes such as developing optimal employment of building loads and distributed energy resources. One year of solar PV power output data was collected and analyzed using one-second resolution to find ideal bounds and levels for the different frequency components. The annual, seasonal, and monthly statistics of the PV frequency content are computed and illustrated in boxplot format. To examine the compatibility of building loads for PV consumption, a spectral analysis of building loads such as Heating, Ventilation and Air-Conditioning (HVAC) units and water heaters was performed. This defined the bandwidth over which these devices can operate. Results show that nearly all of the PV output (about 98%) is contained within frequencies lower than 1 mHz (equivalent to ~15 min), which is compatible for consumption with local building loads such as HVAC units and water heaters. Medium frequencies in the range of ~15 min to ~1 min are likely to be suitable for consumption by fan equipment of variable air volume HVAC systems that have time constants in the range of few seconds to few minutes. This study indicates that most of the PV generation can be consumed by building loads with the help of proper control strategies, thereby reducing impact on the grid and the size of storage systems.

boxplot↗

Thermoviscoplastic analysis of engine cowl leading edge subjected to oscillating shock-shock interaction

A finite element thermoviscoplastic analysis method, which employs a unified constitutive model proposed by Bodner and Partom, is used to predict rate-dependent nonlinear structural behavior. The method is evaluated by predicting stress-strain behavior of a uniaxially loaded bar of nickel-based superalloy (B1900 + Hf) material. The method is used to predict the time-dependent thermoviscoplastic response of a B1900 + Hf leading edge subjected to oscillating shock-shock interaction loading. Viscoplastic analysis shows that the leading edge experiences significant plastic straining. The plastic region increases with cyclic loading in the high heat flux area.

Pandey, Ajay K.↗

Derivation of improved load transformation matrices for launchers-spacecraft coupled analysis, and direct computation of margins of safety

Load and stress recovery from transient dynamic studies are improved upon using an extended acceleration vector in the modal acceleration technique applied to structural analysis. Extension of the normal LTM (load transformation matrices) stress recovery to automatically compute margins of safety is presented with an application to the Hubble space telescope.

Klein, M.↗

Damage Simulation in Non-Crimp Fabric Composite Plates Subjected to Impact Loads

Progressive failure analysis (PFA) of non-crimp fabric (NCF) composite laminates subjected to low velocity impact loads was performed using the COmplete STress Reduction (COSTR) damage model implemented through VUMAT and UMAT41 user subroutines in the frame works of the commercial finite element programs ABAQUS/Explicit and LS-DYNA, respectively. To validate the model, low velocity experiments were conducted and detailed correlations between the predictions and measurements for both intra-laminar and inter-laminar failures were made. The developed material and damage model predicts the peak impact load and duration very close with the experimental results. Also, the simulation results of delamination damage between the ply interfaces, in-plane matrix damages and fiber damages were all in good agreement with the measurements from the non-destructive evaluation data.

Satyanarayana, Arunkumar↗

Experimental Investigation and Finite Element Analysis on Fatigue Behavior of Aluminum Alloy 7050 Single-Lap Joints

The fatigue behavior of single-lap four-riveted aluminum alloy 7050 joints was investigated by using high-frequency fatigue test and scanning electron microscope (SEM). Stress distributions obtained by finite element (FE) analysis help explain the fatigue performance. The fatigue test results showed that the fatigue lives of the joints depend on cold expansion and applied cyclic loads. FE analysis and fractography indicated that the improved fatigue lives can be attributed to the reduction in maximum stress and evolution of fatigue damage at the critical location. The beneficial effects of strengthening techniques result in tearing ridges or lamellar structure on fracture surface, decrease in fatigue striations spacing, delay of fatigue crack initiation, crack deflection in fatigue crack propagation and plasticity-induced crack closure.

36 MATERIALS SCIENCE↗

Thermal interfaces in dynamic compression experiments

Temperature is a difficult thermodynamic variable to measure in dynamic compression experiments. Optical pyrometry is a general-purpose technique for measuring temperature from a radiant surface, but that surface is often the interface between distinct materials with temperatures that vary spatially along the loading direction. This leads to a fundamental problem: how does the measured interface temperature relate to this temperature profile along the compression axis? Numerical analysis of loading history and thermal diffusion at these interfaces shows that seemingly subtle changes in experiment geometry can lead to very different temperature profiles. We compare these results to laboratory temperature measurements of shock-compressed tin.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Detailed End Use Load Modeling for Distribution System Analysis

The field of distribution system analysis has made significant advances in the past ten years. It is now standard practice when performing a power flow simulation to use an algorithm that is capable of unbalanced per-phase analysis. Recent work has also focused on examining the need for time-series simulations instead of examining a single time period, i.e., peak loading. One area that still requires a significant amount of work is the proper modeling of end use loads. Currently it is common practice to use a simple load model consisting of a combination of constant power, constant impedance, and constant current elements. While this simple form of end use load modeling is sufficient for a single point in time, the exact model values are difficult to determine and it is inadequate for some time-series simulations. This paper will examine how to improve simple time invariant load models as well as develop multi-state time variant models.

99 GENERAL AND MISCELLANEOUS↗

Numerical Stress Analysis during Cooldown and Compressive Loading in an Imperfect Nb 3 Sn Wire

In this paper, high field superconductors are critical to the success of next step magnetic fusion confinement devices such as ITER and DEMO. The low-temperature superconducting material that is currently favored for these applications, Nb 3 Sn, is susceptible to performance due to its brittleness and high strain-sensitivity. Under extreme loads, an irreversible degradation in the maximum critical current density has been shown to occur and believed to be strongly influenced by two factors: plasticity and cracked filaments. Cracks in filaments are induced when sufficiently high stress concentrations occur in the wire. In this paper, we explore using finite element analysis the impact that voids have on the stress distributions and peak stresses under two loading conditions: transverse compressive loading in a 2D model, and a full cool down phase in a 3D model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Probabilistic Sensitivity Analysis for Launch Vehicles with Varying Payloads and Adapters for Structural Dynamics and Loads

This paper examines Probabilistic Sensitivity Analysis (PSA) methods and tools in an effort to understand their utility in vehicle loads and dynamic analysis. Specifically, this study addresses how these methods may be used to establish limits on payload mass and cg location and requirements on adaptor stiffnesses while maintaining vehicle loads and frequencies within established bounds. To this end, PSA methods and tools are applied to a realistic, but manageable, integrated launch vehicle analysis where payload and payload adaptor parameters are modeled as random variables. This analysis is used to study both Regional Response PSA (RRPSA) and Global Response PSA (GRPSA) methods, with a primary focus on sampling based techniques. For contrast, some MPP based approaches are also examined.

McGhee, David S.↗