Search NASA⌕ Search

SEARCH · Search NASA

Results for “location map”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Likelihood-based interactive local docking into cryo-EM maps in ChimeraX

The interpretation of cryo-EM maps often includes the docking of known or predicted structures of the components, which is particularly useful when the map resolution is worse than 4 Å. Although it can be effective to search the entire map to find the best placement of a component, the process can be slow when the maps are large. However, frequently there is a well-founded hypothesis about where particular components are located. In such cases, a local search using a map subvolume will be much faster because the search volume is smaller, and more sensitive because optimizing the search volume for the rotation-search step enhances the signal to noise. A Fourier-space likelihood-based local search approach, based on the previously published em_placement software, has been implemented in the new emplace_local program. Tests confirm that the local search approach enhances the speed and sensitivity of the computations. An interactive graphical interface in the ChimeraX molecular-graphics program provides a convenient way to set up and evaluate docking calculations, particularly in defining the part of the map into which the components should be placed.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation criteria for software classification inventories, accuracies, and maps

Statistical criteria are presented for modifying the contingency table used to evaluate tabular classification results obtained from remote sensing and ground truth maps. This classification technique contains information on the spatial complexity of the test site, on the relative location of classification errors, on agreement of the classification maps with ground truth maps, and reduces back to the original information normally found in a contingency table.

Jayroe, R. R., Jr.↗

Two-level Clustering-based Target Detection Through Sensor Deployment and Data Fusion

Target detection is one fundamental problem in many sensor network-based applications, which is typically tackled in two separate stages for sensor deployment and data fusion. We propose an integrated solution, referred to as 2C-SSEM,which combines 2-level clustering-based sensor deployment and source strength estimate map-based data fusion for the detection of a single static or moving target. 2C-SSEM conducts the first level of clustering to determine a sensor deployment scheme and the second level of clustering to divide the deployed sensors into several subsets. For each sensor, the source strength is estimated at each grid point of the entire region based on a signal attenuation model, and for each subset of sensors, the target location is estimated using a distribution map-based statistical analysis method. A final detection decision is made by thresholding the clustering degree of the target location estimates computed by all subsets of sensors. Compared with traditional grid-based target detection methods, 2C-SSEM significantly reduces the computation complexity and improves the detection performance through an integrated optimization strategy. Extensive simulation results show the performance superiority of the proposed solution over several well-known methods for target detection.

Rao, Nageswara↗

Computer graphics aid mission operations

The application of computer graphics techniques in NASA space missions is reviewed. Telemetric monitoring of the Space Shuttle and its components is discussed, noting the use of computer graphics for real-time visualization problems in the retrieval and repair of the Solar Maximum Mission. The use of the world map display for determining a spacecraft's location above the earth and the problem of verifying the relative position and orientation of spacecraft to celestial bodies are examined. The Flight Dynamics/STS Three-dimensional Monitoring System and the Trajectroy Computations and Orbital Products System world map display are described, emphasizing Space Shuttle applications. Also, consideration is given to the development of monitoring systems such as the Shuttle Payloads Mission Monitoring System and the Attitude Heads-Up Display and the use of the NASA-Goddard Two-dimensional Graphics Monitoring System during Shuttle missions and to support the Hubble Space Telescope.

Jeletic, James F.↗

Emplacement of multiple flow units on very shallow slopes, east Kawelu Planitia flow field, Venus

Lobate flows with variable radar brightness occur at several locations on Venus. Here we present preliminary mapping results for a lava flow field on the eastern side of Kawelu Planitia, centered at approximately 41 deg N, 251 deg E. Numerous individual flows of varying brightness can be traced for up to 400 km at this location. Megallan image F-MIDRP.40N251;1 contains two major flow complexes as well as a distinct minor flow field associated with a volcanic dome. The southern flow field (unit F) changes from radar dark to radar bright in a convex arc from west to east. The flow path is diverted by a ridge system (unit B) and associated N-S faulted zone (unit A) evident in the Magellan altimetry data. The 130-km-long radar-bright flow field located at 41.5 deg N and 249-250 deg E is comprised of a narrow, channeled flow (unit E) overlying an intermediate brightness flow (unit D), all of which appears to emanate from a solitary dome at 249 deg E. The southern lobe of unit E disappears under a broad leveed channel (41.3 deg N, 250.1 deg E) in unit 5, only to reappear south of the unit 5 boundary. The source of this largest flow field is not evident, but could be associated with the region of small domes west of the F-MIDRP image (centered at 41 deg N, 246 deg E). Another possible source is the fractured area south of unit C. The flow complex is clearly a conglomeration of many flow episodes, not necessarily from a single source.

Helgerud, Michael B.↗

Innovative Use of Cr(VI) Plume Depictions and Pump-and-Treat Capture Analysis to Estimate Risks of Contaminant Discharge to Surface Water at Hanford Reactor Areas

The Hanford Site nuclear reactor operations required large quantities of high-quality cooling water, which was treated with chemicals including sodium dichromate dihydrate for corrosion control. Cooling water leakage, as well as intentional discharge of cooling water to ground during upset conditions, produced extensive groundwater recharge mounds consisting largely of contaminated cooling water and resulted in wide distribution of hexavalent chromium (Cr[VI]) contamination in the unconfined aquifer. The 2013 Cr(VI) groundwater plumes in the 100 Areas cover approximately 6 km2 (1500 acres), primarily in the 100-HR-3 and 100-KR-4 groundwater operable units (OUs). The Columbia River is a groundwater discharge boundary; where the plumes are adjacent to the Columbia River there remains a potential to discharge Cr(VI) to the river at concentrations above water quality criteria. The pump-and-treat systems along the River Corridor are operating with two main goals: 1) protection of the Columbia River, and 2) recovery of contaminant mass. An evaluation of the effectiveness of the pump-and-treat systems was needed to determine if the Columbia River was protected from contamination, and also to determine where additional system modifications may be needed. In response to this need, a technique for assessing the river protection was developed which takes into consideration seasonal migration of the plume and hydraulic performance of the operating well fields. Groundwater contaminant plume maps are generated across the Hanford Site on an annual basis. The assessment technique overlays the annual plume and the capture efficiency maps for the various pump and treat systems. The river protection analysis technique was prepared for use at the Hanford site and is described in detail in M.J. Tonkin, 2013. Interpolated capture frequency maps, based on mapping dynamic water level observed in observation wells and derived water levels in the vicinity of extraction and injection wells, are developed initially. Second, simulated capture frequency maps are developed, based on transport modelling results. Both interpolated and simulated capture frequency maps are based on operation of the systems over a full year. These two capture maps are then overlaid on the plume distribution maps for inspection of the relative orientation of the contaminant plumes with the capture frequency. To quantify the relative degree of protection of the river from discharges of Cr(VI) (and conversely, the degree of threat) at any particular location, a systematic method of evaluating and mapping the plume/capture relationship was developed. By comparing the spatial relationship between contaminant plumes and hydraulic capture frequency, an index of relative protectiveness is developed and the results posted on the combined plume/capture plan view map. Areas exhibiting lesser degrees of river protection are identified for remedial process optimization actions to control plumes and prevent continuing discharge of Cr(VI) to the river.

Miller, Chuck W.↗

Innovative use of Cr(VI) plume depictions and pump-and-treat capture analysis to estimate risks of contaminant discharge to surface water at Hanford reactor areas - 15315

The Hanford Site nuclear reactor operations required large quantities of high-quality cooling water, which was treated with chemicals including sodium dichromate dihydrate for corrosion control. Cooling water leakage, as well as intentional discharge of cooling water to ground during upset conditions, produced extensive groundwater recharge mounds consisting largely of contaminated cooling water and resulted in wide distribution of hexavalent chromium (Cr[VI]) contamination in the unconfined aquifer. The 2013 Cr(VI) groundwater plumes in the 100 Areas cover approximately 6 km{sup 2} (1500 acres), primarily in the 100-HR-3 and 100-KR-4 groundwater operable units (OUs). The Columbia River is a groundwater discharge boundary; where the plumes are adjacent to the Columbia River there remains a potential to discharge Cr(VI) to the river at concentrations above water quality criteria. The pump-and-treat systems along the River Corridor are operating with two main goals: 1) protection of the Columbia River, and 2) recovery of contaminant mass. An evaluation of the effectiveness of the pump-and-treat systems was needed to determine if the Columbia River was protected from contamination, and also to determine where additional system modifications may be needed. In response to this need, a technique for assessing the river protection was developed which takes into consideration seasonal migration of the plume and hydraulic performance of the operating well fields. Groundwater contaminant plume maps are generated across the Hanford Site on an annual basis. The assessment technique overlays the annual plume and the capture efficiency maps for the various pump and treat systems. The river protection analysis technique was prepared for use at the Hanford site and is described in detail in M.J. Tonkin, 2013. Interpolated capture frequency maps, based on mapping dynamic water level observed in observation wells and derived water levels in the vicinity of extraction and injection wells, are developed initially. Second, simulated capture frequency maps are developed, based on transport modelling results. Both interpolated and simulated capture frequency maps are based on operation of the systems over a full year. These two capture maps are then overlaid on the plume distribution maps for inspection of the relative orientation of the contaminant plumes with the capture frequency. To quantify the relative degree of protection of the river from discharges of Cr(VI) (and conversely, the degree of threat) at any particular location, a systematic method of evaluating and mapping the plume/capture relationship was developed. By comparing the spatial relationship between contaminant plumes and hydraulic capture frequency, an index of relative protectiveness is developed and the results posted on the combined plume/capture plan view map. Areas exhibiting lesser degrees of river protection are identified for remedial process optimization actions to control plumes and prevent continuing discharge of Cr(VI) to the river. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TRACER Lightning Mapping Array Field Campaign Report

Our observational contribution to the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Tracking Aerosol Convection Interactions Experiment (TRACER) was the deployment of additional Lightning Mapping Array sensors to provide enhanced capability to the Houston Lightning Mapping Array (HLMA) during the TRACER intensive operational period. To that end, the Texas Tech University personnel (Professor Bruning and Dr. Brunner, and graduate students Jessica Souza, David Singewald, Stephanie Weiss, and Matthew Miller) deployed two portable LMA antennae at locations G and B shown in the map below. The map also shows the predicted lightning flash detection efficiency in black contours, as well as color-shaded very-high-frequency (VHF) source detection efficiency, which roughly corresponds to the sensitivity to lightning channel detail. Feeds from these sensors were integrated in the HLMA processing in real-time and in post-processing, partially leveraging National Science Foundation support through the TRACER campaign that supported the core HLMA, operated by Timothy Logan.

54 ENVIRONMENTAL SCIENCES↗

TRACER Lightning Mapping Array Field Campaign Report

Our observational contribution to the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s Tracking Aerosol Convection Interactions Experiment (TRACER) was the deployment of additional Lightning Mapping Array sensors to provide enhanced capability to the Houston Lightning Mapping Array (HLMA) during the TRACER intensive operational period. To that end, the Texas Tech University personnel (Professor Bruning and Dr. Brunner, and graduate students Jessica Souza, David Singewald, Stephanie Weiss, and Matthew Miller) deployed two portable LMA antennae at locations G and B shown in the map below. The map also shows the predicted lightning flash detection efficiency in black contours, as well as color-shaded very-high-frequency (VHF) source detection efficiency, which roughly corresponds to the sensitivity to lightning channel detail.

Tracking Aerosol Convection Interactions Experimen↗

Molecular cloning, genomic organization, chromosome mapping, tissues expression pattern and identification of a novel splicing variant of porcine CIDEb gene

Cell death-inducing DNA fragmentation factor-α-like effector b (CIDEb) is a member of the CIDE family of apoptosis-inducing factors, CIDEa and CIDEc have been reported to be Lipid droplets (LDs)-associated proteins that promote atypical LD fusion in adipocytes, and responsible for liver steatosis under fasting and obese conditions, whereas CIDEb promotes lipid storage under normal diet conditions [1], and promotes the formation of triacylglyceride-enriched VLDL particles in hepatocytes [2]. Here, we report the gene cloning, chromosome mapping, tissue distribution, genetic expression analysis, and identification of a novel splicing variant of the porcine CIDEb gene. Sequence analysis shows that the open reading frame of the normal porcine CIDEb isoform covers 660bp and encodes a 219-amino acid polypeptide, whereas its alternative splicing variant encodes a 142-amino acid polypeptide truncated at the fourth exon and comprised of the CIDE-N domain and part of the CIDE-C domain. The deduced amino acid sequence of normal porcine CIDEb shows an 85.8% similarity to the human protein and 80.0% to the mouse protein. The CIDEb genomic sequence spans approximately 6KB comprised of five exons and four introns. Radiation hybrid mapping demonstrated that porcine CIDEb is located at chromosome 7q21 and at a distance of 57cR from the most significantly linked marker, S0334, regions that are syntenic with the corresponding region in the human genome. Tissue expression analysis indicated that normal CIDEb mRNA is ubiquitously expressed in many porcine tissues. It was highly expressed in white adipose tissue and was observed at relatively high levels in the liver, lung, small intestine, lymphatic tissue and brain. The normal version of CIDEb was the predominant form in all tested tissues, whereas the splicing variant was expressed at low levels in all examined tissues except the lymphatic tissue. Furthermore, genetic expression analysis indicated that CIDEb mRNA levels were significantly higher in the white adipose tissue of lean pigs than their obese counterparts, in contrast to porcine CIDEa and CIDEc [3]. We therefore speculate that CIDEb may play a contrary role to the other CIDEs. The basic molecular information we provide here will be useful for further investigations of the physiological function of the gene, which will be helpful in better understanding the role of the CIDE family in lipid metabolism in pig models.

60 APPLIED LIFE SCIENCES↗

A machine learning approach for particle accelerator errant beam prediction using spatial phase deviation

Particle accelerators are extremely complex systems that are expected to operate on high availability. Predicting impending failures only by utilizing data collected from diagnostic equipment already on board can help operators to avoid installing expensive sensors, unscheduled downtime and associated costs. For this purpose we explore the predictive power of Machine Learning algorithms to detect faulty beams prior to the failure. In this study, we propose a Machine Learning approach to model mapping from a pair of sensors located across the accelerator. While the model is trained to represent normal operation, we evaluate the predictive performance on known faulty beam pulses. We also investigate the model performance on unseen data through k-fold cross-validation. Then we recap the analysis with a neural architecture search and hyperparameter optimization study to fine tune our initial model. In conclusion, this paper will also introduce a sustainable framework that can standardize Machine Learning workflow applied to particle accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three‐Dimensional Broadband Interferometric Mapping and Polarization (BIMAP‐3D) Observations of Lightning Discharge Processes

Abstract Following on our earlier single‐station, 2‐dimensional (2D) broadband interferometric mapping and polarization (BIMAP) observations of lightning discharges, we recently deployed two BIMAP stations at Los Alamos National Laboratory to map the lightning sources and their polarization in full 3‐dimensional (3D) space (BIMAP‐3D). The two stations are separated by 11.5‐km and each station consists of four antenna sets (instead of three for the original BIMAP) that form a Y ‐shaped array for improved interferometric performance. In this paper, we report the BIMAP‐3D system design, a generalized and analytical 2D interferometry technique for noncoplanar antenna array, a two‐stage 3D mapping technique based on geometric triangulation and baseline‐based differential time of arrival, and a technique to reconstruct the polarization orientation in 3D space by combining the 2D polarization results from the two‐station observations. Along with description of the techniques, we demonstrate and discuss the initial lightning results, including 3D maps for a hybrid intracloud and cloud‐to‐ground flash and for a normal intracloud flash, development of abnormal K‐change leaders, and polarization signatures for a K‐change leader. We find that with the two‐stage 3D mapping techniques, the sources can be located to meters accuracy for a favorable event that occurs between the two stations. We also find the polarization vectors for the example K leader are mostly orthogonal to the leader channel after the full 3D polarization analysis. The main purpose of this paper is to report the BIMAP‐3D techniques and capabilities. Detailed analysis of more specific discharge processes will be reported in later studies.

54 ENVIRONMENTAL SCIENCES↗

Revealing multiple classes of stable quantum emitters in hexagonal boron nitride with correlated optical and electron microscopy

Defects in hexagonal boron nitride (hBN) exhibit high-brightness, room-temperature quantum emission, but their large spectral variability and unknown local structure challenge their technological utility. Here, we directly correlate hBN quantum emission with local strain using a combination of photoluminescence (PL), cathodoluminescence (CL) and nanobeam electron diffraction. Across 40 emitters, we observe zero phonon lines (ZPLs) in PL and CL ranging from 540 to 720 nm. CL mapping reveals that multiple defects and distinct defect species located within an optically diffraction-limited region can each contribute to the observed PL spectra. Local strain maps indicate that strain is not required to activate the emitters and is not solely responsible for the observed ZPL spectral range. Instead, at least four distinct defect classes are responsible for the observed emission range, and all four classes are stable upon both optical and electron illumination. Our findings offer a foundation for future atomic-scale optical characterization of colour centres.

36 MATERIALS SCIENCE↗

Heavy Ion Radiation Effects Studies With Ion Photon Emission Microscopy

The development of a new radiation effects microscopy (REM) technique is crucial as emerging semiconductor technologies demonstrate smaller feature sizes and thicker back end of line (BEOL) layers. To penetrate these materials and still deposit sufficient energy into the device to induce single event effects, high energy heavy ions are required. Ion photon emission microscopy (IPEM) is a technique that utilizes coincident photons, which are emitted from the location of each ion impact to map out regions of radiation sensitivity in integrated circuits and devices, circumventing the obstacle of focusing high-energy heavy ions. Several versions of the IPEM have been developed and implemented at Sandia National Laboratories (SNL). One such instrument has been utilized on the microbeam line of the 6 MV tandem accelerator at SNL. Another IPEM was designed for ex-vacu use at the 88'' cyclotron at Lawrence Berkeley National Laboratory (LBNL). Extensive engineering is involved in the development of these IPEM systems, including resolving issues with electronics, event timing, optics, phosphor selection, and mechanics. The various versions of the IPEM and the obstacles, as well as benefits associated with each will be presented. In addition, the current stage of IPEM development as a user instrument will be discussed in the context of recent results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-sensing cantilevers with integrated conductive coaxial tips for high-resolution electrical scanning probe metrology

The lateral resolution of many electrical scanning probe techniques is limited by the spatial extent of the electrostatic potential profiles produced by their probes. Conventional unshielded conductive atomic force microscopy probes produce broad potential profiles. Shielded probes could offer higher resolution and easier data interpretation in the study of nanostructures. Electrical scanning probe techniques require a method of locating structures of interest, often by mapping surface topography. As the samples studied with these techniques are often photosensitive, the typical laser measurement of cantilever deflection can excite the sample, causing undesirable changes electrical properties. In this work, we present the design, fabrication, and characterization of probes that integrate coaxial tips for spatially sharp potential profiles with piezoresistors for self-contained, electrical displacement sensing. With the apex 100 nm above the sample surface, the electrostatic potential profile produced by our coaxial tips is more than 2 times narrower than that of unshielded tips with no long tails. In a scan bandwidth of 1 Hz–10 kHz, our probes have a displacement resolution of 2.9 Å at 293 K and 79 Å at 2 K, where the low-temperature performance is limited by amplifier noise. We show scanning gate microscopy images of a quantum point contact obtained with our probes, highlighting the improvement to lateral resolution resulting from the coaxial tip.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-RAY INVESTIGATION OF THE DIFFUSE EMISSION AROUND PLAUSIBLE {gamma}-RAY EMITTING PULSAR WIND NEBULAE IN KOOKABURRA REGION

We report on the results from Suzaku X-ray observations of the radio complex region called Kookaburra, which includes two adjacent TeV {gamma}-ray sources HESS J1418-609 and HESS J1420-607. The Suzaku observation revealed X-ray diffuse emission around a middle-aged pulsar PSR J1420-6048 and a plausible pulsar wind nebula (PWN) Rabbit with elongated sizes of {sigma}{sub X} = 1.'66 and {sigma}{sub X} = 1.'49, respectively. The peaks of the diffuse X-ray emission are located within the {gamma}-ray excess maps obtained by H.E.S.S. and the offsets from the {gamma}-ray peaks are 2.'8 for PSR J1420-6048 and 4.'5 for Rabbit. The X-ray spectra of the two sources were well reproduced by absorbed power-law models with {Gamma} = 1.7-2.3. The spectral shapes tend to become softer according to the distance from the X-ray peaks. Assuming the one-zone electron emission model as the first-order approximation, the ambient magnetic field strengths of HESS J1420-607 and HESS J1418-609 can be estimated as 3 {mu}G and 2.5 {mu}G, respectively. The X-ray spectral and spatial properties strongly support that both TeV sources are PWNe, in which electrons and positrons accelerated at termination shocks of the pulsar winds are losing their energies via the synchrotron radiation and inverse Compton scattering as they are transported outward.

79 ASTRONOMY AND ASTROPHYSICS↗

The bones of the Milky Way

The very long and thin infrared dark cloud 'Nessie' is even longer than had been previously claimed, and an analysis of its Galactic location suggests that it lies directly in the Milky Way's mid-plane, tracing out a highly elongated bone-like feature within the prominent Scutum-Centaurus spiral arm. Re-analysis of mid-infrared imagery from the Spitzer Space Telescope shows that this infrared dark cloud (IRDC) is at least two and possibly as many as five times longer than had originally been claimed by Nessie's discoverers; its aspect ratio is therefore at least 300:1 and possibly as large as 800:1. A careful accounting for both the Sun's offset from the Galactic plane (∼25 pc) and the Galactic center's offset from the (l{sup II} , b{sup II} ) = (0, 0) position shows that the latitude of the true Galactic mid-plane at the 3.1 kpc distance to the Scutum-Centaurus Arm is not b = 0, but instead closer to b = –0.4, which is the latitude of Nessie to within a few parsecs. An analysis of the radial velocities of low-density (CO) and high-density (NH{sub 3}) gas associated with the Nessie dust feature suggests that Nessie runs along the Scutum-Centaurus Arm in position-position-velocity space, which means it likely forms a dense 'spine' of the arm in real space as well. The Scutum-Centaurus Arm is the closest major spiral arm to the Sun toward the inner Galaxy, and, at the longitude of Nessie, it is almost perpendicular to our line of sight, making Nessie the easiest feature to see as a shadow elongated along the Galactic plane from our location. Future high-resolution dust mapping and molecular line observations of the harder-to-find Galactic 'bones' should allow us to exploit the Sun's position above the plane to gain a (very foreshortened) view 'from above' the Milky Way's structure.

79 ASTRONOMY AND ASTROPHYSICS↗

Foregrounds in wide-field redshifted 21 cm power spectra

Detection of 21 cm emission of H i from the epoch of reionization, at redshifts z>6, is limited primarily by foreground emission. We investigate the signatures of wide-field measurements and an all-sky foreground model using the delay spectrum technique that maps the measurements to foreground object locations through signal delays between antenna pairs. We demonstrate interferometric measurements are inherently sensitive to all scales, including the largest angular scales, owing to the nature of wide-field measurements. These wide-field effects are generic to all observations but antenna shapes impact their amplitudes substantially. A dish-shaped antenna yields the most desirable features from a foreground contamination viewpoint, relative to a dipole or a phased array. Comparing data from recent Murchison Widefield Array observations, we demonstrate that the foreground signatures that have the largest impact on the H i signal arise from power received far away from the primary field of view. We identify diffuse emission near the horizon as a significant contributing factor, even on wide antenna spacings that usually represent structures on small scales. For signals entering through the primary field of view, compact emission dominates the foreground contamination. These two mechanisms imprint a characteristic pitchfork signature on the “foreground wedge” in Fourier delay space. Based on these results, we propose that selective down-weighting of data based on antenna spacing and time can mitigate foreground contamination substantially by a factor of ∼100 with negligible loss of sensitivity.

79 ASTRONOMY AND ASTROPHYSICS↗