Search NASASearch

SEARCH · Search NASA

Results for “machine learning interatomic potentials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

708 records · Page 35

Envelope-driven comfort risk in residential demand response

Residential demand response (DR) is a valuable resource for grid reliability, but remains challenging because the highly heterogeneous residential building stock leads to widely varying and hard-to-predict load and comfort responses during DR events. Although prior research has estimated the technical potential of DR-capable technologies for achieving energy demand savings, little is known about how they affect thermal comfort. In particular, it remains unclear how indoor thermal conditions due to DR depend on the thermal envelope characteristics of the housing stock. To address this gap, this study provides a systematic, location-specific assessment of indoor thermal performance during DR-events across the US housing stock using both typical DR weather data and detailed building metadata. We evaluate how envelope characteristics influence indoor temperatures during realistic simulated summer and winter DR events across 37 US locations, applying both temperature threshold and rate of temperature change criteria to estimate region-level probabilities of discomfort. Additionally, we show the impact of distinct weather patterns that intensify or abate thermal stress on comfort outcomes. Results show a near-universal overheating risk in summer DR events, where comfort outcomes are strongly influenced by rapid risk of comfort violations. In contrast, overall winter DR discomfort risk is lower, risk escalation is more gradual and shows greater sensitivity to event duration. These findings offer a data-driven quantification of comfort risk across diverse climates and building envelopes, demonstrating the need for region-specific DR scheduling and discomfort mitigation strategies tailored to local weather patterns and the performance of existing residential buildings.

Demand response

Linking international technical specifications for acoustic characterization of marine energy converter sounds with environmental compliance criteria

As new ocean energy technologies emerge and are deployed for testing and operations, sound emissions are a potential concern for environmental effects to marine life. Consistent acoustic measurement and data analysis methods can help promote comparisons of technologies and transferability between project sites. In 2022, acoustic emissions from a prototype scale wave energy converter (WEC) were characterized for a range of environmental conditions and power generation states in the coastal waters off southern California using a set of international technical specifications. Results from the international technical specification analyses were applied to United States regulatory threshold criteria for acoustic impacts to marine mammals and examined in the context of European underwater noise monitoring guidelines. Weighted 24 hour cumulative sound exposure levels SEL24h calculated from the highest power generation state WEC sound pressure levels were often more than 20 dB below threshold criteria for temporary threshold shifts in five relevant marine mammal hearing groups. Following European Union recommendations for analyses and reporting, WEC sound characterization in third octave bands centered at 63 Hz and 125 Hz show clear spatial decay of WEC-generated noise, with more pronounced attenuation at 63 Hz, and a less marked but still detectable gradient at 125 Hz, collectively suggesting a relatively confined acoustic footprint under the observed conditions. The value of the international technical specification approach is highlighted by the isolation of WEC sounds from the surrounding soundscape. This allows for a robust characterization of acoustic emissions through a range of device power generation and sea states. Furthermore, in threshold-based regulatory contexts like the U.S., this facilitates direct evaluation of source contributions, while in broader monitoring frameworks used in the E.U. it provides a reproducible foundation for assessing the contribution of emerging ocean energy technologies to the underwater acoustic environment.

Haxel, Joseph H. (ORCID:0000000273864761)

Spacecraft Water Impurity Monitor, a System for Water Quality Analysis on Exploration Missions Beyond Low Earth Orbit

Exploration missions beyond low-earth-orbit (LEO) will require advanced instrumentation to monitor water quality. Traveling beyond LEO means the transfer of water samples to an Earth-based laboratory for detailed analysis is not feasible. Detailed analysis of water composition during exploration is still necessary, because having the capability to determine the specific organic chemical causing a change in total organic carbon (TOC) or the specific metal or ionic species causing a change in conductivity has the potential to inform the crew health and system management decisions. On a new vehicle such as a lunar or Mars surface habitat or a Mars transit vehicle, finding “new” impurities not seen on ISS should be expected. The key is to identify the impurity so the correct action can be taken. On ISS we can measure TOC, conductivity, and other physical properties but do not have the capability for detailed analysis using vehicle instrumentation. This is acceptable because ISS can send samples down to Earth for further analysis and obtain the detailed composition. The Spacecraft Water Impurity Monitor (SWIM) will provide detailed water quality analysis for missions in which sample down mass is not available. SWIM is a system comprising organic and inorganic analysis modules. For organic chemicals, a gas chromatograph mass spectrometer (GCMS) detects and identifies organic impurities. For inorganic species, a capillary electrophoresis capacitively coupled contactless conductivity detection (CE-C4D) system as well as ion specific electrodes detect and identify metal ions and other inorganic salts / acids. The SWIM technology demonstration project has completed a System Requirements Review (SRR) to finalize detection requirements and is currently working to refine vehicle interface requirements for a future technology demonstration. The project also has begun preliminary flight design activities for the core analyzers in the instrument suite.

Water Monitoring

High Sulfur Loading and Capacity Retention in Bilayer Garnet Sulfurized‐Polyacrylonitrile/Lithium‐Metal Batteries with Gel Polymer Electrolytes

The cubic‐garnet (Li 7 La 3 Zr 2 O 12 , LLZO) lithium–sulfur battery shows great promise in the pursuit of achieving high energy densities. The sulfur used in the cathodes is abundant, inexpensive, and possesses high specific capacity. In addition, LLZO displays excellent chemical stability with Li metal; however, the instabilities in the sulfur cathode/LLZO interface can lead to performance degradation that limits the development of these batteries. Therefore, it is critical to resolve these interfacial challenges to achieve stable cycling. Here, an innovative gel polymer buffer layer to stabilize the sulfur cathode/LLZO interface is created. Employing a thin bilayer LLZO (dense/porous) architecture as a solid electrolyte and significantly high sulfur loading of 5.2 mg cm −2 , stable cycling is achieved with a high initial discharge capacity of 1542 mAh g −1 (discharge current density of 0.87 mA cm −2 ) and an average discharge capacity of 1218 mAh g −1 (discharge current density of 1.74 mA cm −2 ) with 80% capacity retention over 265 cycles, at room temperature (22 °C) and without applied pressure. Achieving such stability with high sulfur loading is a major step in the development of potentially commercial garnet lithium–sulfur batteries.

25 ENERGY STORAGE

A Python Tool for Aqueous Plutonium Nitrate Density Law Input Preprocessing in MCNP6

Here, this work develops a predictive density tool in Python, named Plutonium Nitrate Solutions (PuNS), to reduce bias and uncertainty in nuclear criticality safety calculations for plutonium nitrate systems. The Pitzer method and an empirical method were implemented into the PuNS tool to generate atom densities for use in MCNP6 material cards. These material cards are directly prepared into an MCNP6 input text file and are calculated based on customizable user inputs of plutonium content, nitric acid content, temperature, and plutonium isotope weight percentages. The PuNS tool is validated and verified against the International Criticality Safety Benchmark Evaluation Project Handbook experiments and is observed to predict densities within a root mean square error of 0.89% for the Pitzer method and 1.82% for the empirical method. These errors in density lead to up to 1569 pcm difference in MCNP6 calculated k eff for the Pitzer method and up to a 1751 pcm difference for the empirical method when compared to experimental benchmarks. Simultaneous work is also being performed at Los Alamos National Laboratory and the University of New Mexico to create a similar tool for plutonium chloride solutions, named Plutonium Chloride Solution, which aims to provide the accreditation of the chlorine absorption. These capabilities will not only provide more accurate models but also facilitate an improved understanding of solution systems and a potential relaxation in the conservatism of current aqueous plutonium processing criticality safety limits.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA

Conceptual design study of neutron detectors for safeguards measurement of an irradiated pebble

Nuclear material control and accounting (MC&A) of pebble-bed reactors (PBRs) is challenging because a PBR utilizes hundreds of thousands of identical, unmarked pebbles that are continuously recirculated through the core. To develop tools that enable the implementation of international safeguards, especially in the context of MC&A of spent pebbles, we designed and simulated three neutron detection concepts to determine fissile content in individual pebbles: a differential die-away (DDA) detector, a californium interrogation prompt neutron (CIPN) detector, and a passive neutron albedo reactivity (PNAR) detector using Monte Carlo calculations. Burnup calculations were performed on the spent pebbles from the PBMR-400 classic PBR. The varying neutron and gamma source terms, and isotopic compositions in the spent pebbles calculated at various burnup levels were used in the neutron detector models. DDA was found to be sensitive to the number of passes a pebble has had through the core and to the fissile content contained in a spent pebble. Optimization in the DDA design further increased the neutron count rates and thus reduced counting uncertainty. Meanwhile, passive neutron counting using the same detector body could distinguish pebbles with different numbers of passes, but its response was dominated by neutron-emitting actinides and was not sensitive to fissile content. On the other hand, the PNAR technique was not viable for a single pebble but performed reasonably for a 27-pebble array, which suggested potential use for verification measurements of containers filled with 27 or more spent pebbles.

CIPN

A Modular Conjugate Heat Transfer Optimization Framework for Thermal Management of Electric Aircraft

Conjugate heat transfer (CHT) analysis and optimization is a powerful method for improving thermal management, as it simultaneously resolves the temperature distribution in both fluid and solid domains. This paper presents a modular, discrete adjoint-based CHT optimization capability integrated within the OpenMDAO/MPhys framework. A unique feature of the proposed framework is its flexibility to extend to multidisciplinary optimization, including aero-structural-thermal applications. The fluid domain is modeled using a finite-volume Computational Fluid Dynamics (CFD) solver, and the solid domain with a conduction heat transfer solver. A mixed Neumann-Dirichlet boundary condition is developed to enable full submersion of the solid geometry within the fluid domain, while ensuring consistent temperature and heat flux coupling at the CHT interface. Gradient-based optimization is performed; the gradients are efficiently computed using the discrete adjoint solvers implemented in DAFoam. To demonstrate the method, this paper considers two cases related to electric aircraft thermal management: a U-bend heat exchanger and an actively cooled battery pack. The U-bend case aims to minimize pressure loss while maximizing heat flux by changing the pipe geometry. The optimized design reduces pressure loss by 52.7% and increases total heat flux by 2.3%. In the battery pack case, a 3-by-3 cell configuration is cooled by ambient airflow, with constant heat generation prescribed in the cells. The battery casing shape serves as the design variable, and the objective function is a weighted sum of pressure loss and pack weight, subject to a maximum temperature constraint. The optimized design achieves a 44.6% reduction in pressure loss and a 1.5% reduction in weight, while satisfying the thermal constraint. To ensure the reliability of the optimized designs, this study validates coarse-mesh, steady-state predictions against fine-mesh unsteady simulations, demonstrating consistency within acceptable errors. This work demonstrates the potential of the developed framework to enable rapid, high-fidelity design of thermal management systems for electric aircraft.

heat transfer

EvoDiffMol: evolutionary diffusion framework for 3D molecular design with optimized properties

Designing molecules with specific target properties remains a fundamental challenge in computational chemistry. While existing approaches show promise, most rely on simplified representations like SMILES strings or 2D graphs that lack essential three-dimensional geometric information. We present EvoDiffMol, a computational framework that integrates evolutionary algorithms with three-dimensional diffusion models for property-driven molecular generation. The method operates through adaptive evolutionary optimization, where population-based selection guides the generation process toward desired property landscapes. EvoDiffMol supports both unconstrained molecular design and scaffold-constrained generation that preserves fixed substructures while optimizing complementary regions. Comprehensive evaluation demonstrates exceptional performance, achieving the highest drug-likeness score (0.94) among all compared state-of-the-art methods while maintaining excellent validity, uniqueness, and novelty. Beyond single property optimization, the framework demonstrates flexible multi-property optimization capabilities, simultaneously controlling multiple molecular descriptors including synthetic accessibility, lipophilicity, topological polar surface area, and clinically relevant ADMET properties such as cardiotoxicity (hERG) and intestinal permeability (Caco-2). This adaptability spans from simple descriptors to practical pharmaceutical endpoints without requiring complete model retraining. The framework achieves precise control over target property values, generating molecules with properties closely matching specified targets for both single and multiple descriptors. Scaffold-constrained experiments preserve fixed molecular cores while maintaining effective property optimization. The three-dimensional representation offers advantages in maintaining structural validity during iterative optimization, with potential for geometry-aware applications in materials science and drug discovery.

3D molecular generation

Electron-Deficient Phenazines: Synthesis, Structures, Redox, and Optoelectronic Properties in the Gas Phase, in Solution, and in the Solid State

High-temperature gas-phase reactions of 1,4-C4F8I2 with phenazine (PHNZ) afforded new thermally- and air-stable derivatives with cyclo-C4F8 substituents, viz. 1,2-PHNZ(C4F8), 2,3-PHNZ(C4F8), 1,2:6,7-PHNZ(C4F8)2, 1,2:7,8-PHNZ(C4F8)2, and 1,2:8,9-PHNZ(C4F8)2. Reactions in the presence of Cu powder resulted in reductive-defluorination/aromatization of some of the cyclo-C4F8 substituents to produce 2,3-PHNZ(C4F4), 2,3-PHNZ(C4HF3), and 1,2:6,7-PHNZ(C4F8)(C4F4), which are formally tri- or tetrafluoro derivatives of benzo[a]phenazine. Single-crystal X-ray diffraction structures of these compounds demonstrate the planarity of 2,3-PHNZ(C4F4) and 2,3-PHNZ(C4HF3) and ordered p-stacking in 1,2-PHNZ(C4HF3), 1,2-PHNZ(C4F4), 1,2-PHNZ(C4F8), and 2,3-PHNZ(C4F8). Low-temperature gas-phase photoelectron spectra of the PHNZ(C4F8)1,2 compounds show that they are strong electron acceptors, with the three PHNZ(C4F8)2 isomers having electron affinities exceeding that of C60. Cyclic voltammetry in acetonitrile show that the five PHNZ(C4F8)1,2 compounds exhibit reversible one-electron reductions with large positive shifts in their reduction potentials relative to unsubstituted PHNZ. Spectroelectrochemical absorption and EPR spectra of PHNZ(C4F8)1,2- • anion radicals and extensive DFT calculations revealed the significant role that the different substitution patterns have on determining the optoelectronic properties of the PHNZ(C4F8)1,2 derivatives and PHNZ(C4F8)1,2- • anion radicals. Time-resolved microwave conductivity measurements and photoluminescence spectra of blends of the PHNZ(C4F8)1,2 derivatives with the donor poly(3-hexylthiophene) (P3HT) were recorded to assess the possible use of the new compounds in optoelectronic devices.

Balser, Sebastian

Giant Exfoliation Induced Magnetic Coercivity in Fe 3 GaTe 2

Permanent magnets with strong anisotropy and high coercivity underpin modern information and energy technologies, yet rare-earth-free alternatives remain limited. Here, we show that thickness engineering via mechanical exfoliation induces hard magnetic behavior in the van der Waals ferromagnet Fe 3 GaTe 2 . Bulk crystals exhibit Curie temperatures above 350 K but negligible room-temperature coercivity. When thinned below ∼100 nm, the coercive field is dramatically enhanced, reaching nearly 1 T at room temperature for in-plane fields—comparable to conventional hard magnets. Micromagnetic analysis reveals a crossover in magnetization reversal from domain-mediated processes in bulk samples to quasi-coherent rotation in thin flakes, driven by increased effective anisotropy and suppressed domain formation. This thickness-dependent transition enables tuning of magnetic hardness without chemical modification. Combined with high saturation magnetization and robust room-temperature performance, Fe 3 GaTe 2 emerges as a promising rare-earth-free material for spintronic applications. Its layered structure further allows integration into van der Waals heterostructures, where large in-plane coercivity can stabilize magnetic states against perturbations and interlayer coupling, offering potential for high-density nonvolatile memory and domain-wall-based devices.

36 MATERIALS SCIENCE

Studies of laser stimulated photodetachment from nanoparticles for particle charge measurements

Determining nanoparticle charge is more challenging than that for microparticles due to change in the particle size during the synthesis substantial plasma property variations, and difficulties in visualizing individual particles, rendering conventional microparticle charge diagnostics ineffective in dusty plasma. In this work, we utilized laser-stimulated photodetachment (LSPD) to deduce the mean charge of nanoparticles. Nanoparticles were grown in an Ar/C 2 H 2 mixture using a capacitively coupled RF discharge and the LSPD induced changes in the electron current monitored by a cylindrical Langmuir probe. LSPD signals were obtained and analyzed across different dust growth phases. The prolonged decay of electron current pulses was attributed to the presence of residual negative ions, caused by the effective electrostatic trapping of these ions and the potential post—LSPD re-formation of new ones. The particle charge was estimated by combining the laser-stimulated photodetachment signal from the probe with the dust density obtained from laser-light extinction using the measured nanoparticle size distribution. For a nanoparticles size range of approximately 100–250 nm and mean diameter of $d$ p ∼154.37 nm, the effective mean charge was estimated to be $\langle$$Q$$\rangle$ d $≈$ 37 elementary charge units. The measured charge values are lower than those predicted by orbital motion limited theory, which may be attributed to significant electron depletion in the nanodusty plasma. LSPD results in Ar/C 2 H 2 nano-dusty plasma confirm the applicability of this method for estimating individual nanoparticle charges. However, it has also been demonstrated that electron detachment from residual background negative ions can influence the detachment current decay and must be carefully considered.

dust particle charge

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Petermann Glacier on the Brink: Progress, Challenges and Insights

Petermann Glacier, the largest marine-terminating glacier in northern Greenland based on catchment area and ice discharge, plays a key role in regulating ice discharge from the Greenland Ice Sheet into the Arctic Ocean. With an upstream catchment connected to the ice sheet interior via a deep subglacial canyon, its future stability has major implications for sea level rise. In this review, we synthesize recent advances in understanding Petermann’s dynamics across three critical interfaces: the ice–ocean, ice–atmosphere, and ice–bed boundaries. At the surface, observations show that reanalysis products underestimate air temperatures and melt, while regional climate models diverge significantly in their estimates of surface mass balance, underscoring the need for improved in situ data and models. At the ocean boundary, enhanced basal melting driven by both subglacial runoff and Atlantic water intrusions is identified as the dominant driver of recent mass loss of Petermann Glacier, with continued warming posing a serious threat to the stability of the floating tongue. At the bed, new geophysical synthesis reveals complex geology, likely spatial variability in geothermal heat flux, and the influence of the megacanyon on seasonal hydrology and velocity fluctuations. Petermann’s mass balance has been negative in recent decades without corresponding flow acceleration. However, the glacier has undergone significant calving events, and the current rifting that began in September 2025 highlights its vulnerability. This upcoming calving event underscores the timeliness of this review, as it will put Petermann Glacier’s terminus at its most retreated position since records began in 1923. The anticipated retreat of the ice tongue also reduces buttressing and brings the terminus closer to the grounding zone, and modeling studies suggest that calving within 12 km of the grounding zone could potentially trigger dynamic retreat, accelerating ice discharge, and a doubling of flow speeds. We conclude that improved observations, sustained monitoring of oceanographic and atmospheric properties, and high-resolution modeling are critical to constraining projections of Petermann Glacier’s future and its role in the stability of the Greenland Ice Sheet.

Dominik Fahrner

Direct observation of distinct bulk and edge nonequilibrium spin accumulation in ultrathin MoTe 2

Low-symmetry two-dimensional (2D) topological materials such as MoTe 2 host efficient charge-to-spin conversion (CSC) mechanisms that can be harnessed for novel electronic and spintronic devices. However, the nature of the various CSC mechanisms and their correlation with underlying crystal symmetries remain unsettled. In this work, we use local spin-sensitive electrochemical potential measurements to directly probe the spatially dependent nonequilibrium spin accumulation in MoTe 2 flakes down to four atomic layers. We are able to clearly disentangle contributions originating from the spin Hall and Rashba-Edelstein effects and uncover an abundance of unconventional spin polarizations that develop uniquely in the sample bulk and edges with decreasing thickness. Using ab-initio calculations, we construct a unified understanding of all the observed CSC components in relation to the material dimensionality and stacking arrangement. Our findings not only illuminate previous CSC results on MoTe 2 but also have important ramifications for future devices that can exploit the local and layer-dependent spin properties of this 2D topological material.

Science & Technology - Other Topics

Vapor-phase pillarization of MXenes for engineering hierarchical interlayer porosity

MXenes, a family of two-dimensional (2D) multilamellar materials, possess excellent thermal and electronic properties for a range of applications. Their use in heterogeneous catalysis, however, is limited by the low surface area resulting from stacked layers. Pillarization with inorganic oxides can create more open, mesoporous MXene structures, improving accessibility for guest species to diffuse, reside or react in the space between 2D layers. A previous liquid-phase pillarization method, however, involves excessive use of solvent-based precursors and multiple processing steps. Here, we report a vapor-phase pillarization (VPP) strategy to introduce pillars, exemplified by silica pillars, with high pillar precursor usage efficiency and a simplified processing workflow. The resulting silica-pillared mesoporous MXene exhibits significantly increased surface area and porosity. These textural properties can be easily tuned by the VPP synthesis conditions. When applied as a ruthenium (Ru) catalyst support for the hydrogenolysis of low-density polyethylene (LDPE), the silica-pillared MXene enabled high Ru dispersion and catalytic activity. This study highlights the potential of the VPP method for engineering mesoporous, 2D MXene materials and demonstrates the effectiveness of mesoporous MXene as a catalyst support in overcoming mass transport and active-site accessibility challenges in heterogeneous catalysis involving bulky substances, such as plastics upcycling.

Luo, Song [University of Delaware, Newark, DE (Uni

Acquisitive root exploration strategies help maintain higher peak sap flux rates during summer drought, but more root biomass does not

Roots are responsible for soil water uptake, yet little is known about how variation in fine-root traits relates to whole-tree water movement, particularly during periods of drought. By combining a 3-yr dataset monitoring sap flow rates with measures of fine-root biomass, length, and morphology across 10 tree species, we addressed hypotheses concerning the role of fine-root system size and morphology in determining tree responses to summer drought as well as potential changes in their relative importance under more severe droughts. Greater fine-root biomass and length did not enable trees to maintain high rates of sap flow during drought, whereas the morphological traits, specific root length and specific root area, were linked to sustained sap flow rates during drought. We found that all species, irrespective of root traits, progressively reduced their sap flow under more extreme drought conditions, although more acquisitive root morphology was still associated with smaller reductions. Our results run counter to long-standing assumptions that larger root systems are better able to access soil water and maintain photosynthetic activity during drought. Instead, we find evidence that root morphology at least partially determines the capacity for water uptake and movement as soil moisture declines.

drought

The Contaminant Footprint of Landed Spacecraft: Toward an Inventory and Modelling Framework

All spacecraft generate and carry contaminants, i.e., unwanted and potentially harmful material. When a spacecraft lands and operates in near-vacuum, as onto Earth’s Moon, it introduces contaminants into its environment that may compromise mission science objectives and engineering performance. Contamination of solar system bodies may irrevocably degrade targets of unique value to planetary scientists, for instance, as lunar landed spacecraft introduce propellant effluents into the otherwise pristine ice of the Moon’s permanently shadowed regions. NASA’s planetary protection discipline seeks to ensure that solar system bodies are not contaminated, for scientific purposes, by terrestrial material (i.e., forward contamination). This interest aligns with planetary science interest in mitigating the transport of terrestrial contaminants onto solar system bodies and in controlling types of contamination that could compromise the scientific value of samples or measurements. NASA, and other entities that practice planetary science, have compelling and multidisciplinary interests in the preservation of special regions and sampling sites of high scientific value – including lunar permanently shadowed regions (PSRs) – from inadvertent contamination by any spacecraft, and in understanding the contamination of such regions by all spacecraft. Organic molecular contamination here represents a primary threat. Organic molecules will be introduced to solar system bodies by nominal landed spacecraft and crew processes – including by the action of descent and ascent engines; natural materials outgassing; and crew environmental and life support system sources. Molecular contaminants can also travel in the free-molecular sense at global scale across near-vacuum bodies, including into regions where they may be permanently trapped. This presentation will address a high-level study to identify sources of contaminants – in particular, organic material – generated by landed spacecraft along with the transport vectors by which these contaminants can reach sites of scientific interest on bodies like the Moon. A vision for an integrated modeling framework for the organic contamination footprint of spacecraft missions, individually and collectively, will also be described and presented along with initial conclusions related to organic molecular transport.

Gas Dynamics

Bipolar Ag-Zn battery

The silver-zinc (AgZn) battery system has been unique in its ability to safely satisfy high power demand applications with low mass and volume. However, a new generation of defense, aerospace, and commercial applications will impose even higher power demands. These new power demands can be satisfied by the development of a bipolar battery design. In this configuration the power consuming, interelectrode current conductors are eliminated while the current is then conducted via the large cross-section electrode substrate. Negative and positive active materials are applied to opposite sides of a solid silver foil substrate. In addition to reducing the weight and volume required for a specified power level, the output voltage performance is also improved as follows. Reduced weight through: elimination of the plastic cell container; elimination of plate leads and intercell connector; and elimination of internal plate current collector. Increased voltage through: elimination of resistance of current collector; elimination of resistance of plate lead; and elimination of resistance of intercell connector. EPI worked previously on development of a secondary bipolar silver zinc battery. This development demonstrated the electrical capability of the system and manufacturing techniques. One difficulty with this development was mechanical problems with the seals. However, recent improvements in plastics and adhesives should eliminate the major problem of maintaining a seal around the periphery of the bipolar module. The seal problem is not as significant for a primary battery application or for a requirement for only a few discharge cycles. A second difficulty encountered was with activation (introducing electrolyte into the cell) and with venting gas from the cell without loss of electrolyte. During previous work, the following projections for energy density were made from test data for a high power system which demonstrated in excess of 50 discharge/charge cycles. Projected system power = 100 kilowatts; discharge time = 30 seconds; discharge current density = 1.75 amps/sq in.; system weight = 86 lbs (9.7 WH/lb); and system volume = 1071 cu. in. (.78 WH/cu. in.). EPI is currently working on a development program to produce a bipolar silver-zinc battery design for NASA. The potential application would be to power electromechanical actuators for space launch vehicles.

Giltner, L. John