Search NASA⌕ Search

SEARCH · Search NASA

Results for “maser”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Relaxation time measurements by an electronic method.

Description of a simple electronic system that permits the direct measurement of time constants of decaying signals. The system was used in connection with relaxation experiments on hydrogen and rubidium masers and was found to operate well. The use of a computing counter in the systems gives the possibility of making averages on several experiments and obtaining the standard deviation of the results from the mean. The program for the computing counter is given.

Brousseau, R.↗

Hyperfine structure of furan.

The hfs of five rotational transitions of furan (C4H4O) has been resolved with a beam maser spectrometer with a resolution of about 500 Hz. All significant details of the observed structure are accounted for by the spin-spin and spin-rotation interactions of the four protons, and the coupling constants for these interactions have been determined to high precision. In particular, the diagonal elements of the spin-rotation tensors have been determined to about 10 Hz.

Tomasevich, G. R.↗

Low-noise microwave receiving systems in a worldwide network of large antennas.

The Deep-Space Network (DSN) consists of a worldwide network of 26- and 64-m antennas spaced approximately 120 deg around the world. The DSN is a precision communications system designed to communicate with and control unmanned spacecraft traveling at interplanetary ranges. Recent developments in the performance and evaluation of the antennas and maser receivers are discussed, and developments which have contributed to radio-science projects, such as planetary radar astronomy, very-long-baseline interferometry, pulsar, and other astronomical observations are described. It is also shown how these radio-science measurements have been used to evaluate the performance of the antenna-receiver systems.

Reid, M. S.↗

Improved thermal isolation for superconducting magnet systems

Closed-cycle refrigerating system for superconductive magnet and maser is operated in vacuum environment. Each wire leading from external power source passes through cooling station which blocks heat conduction. In connection with these stations, switch with small incandescent light bulb, which generates heat, is used to stop superconduction.

Wiebe, E. R.↗

Tunable cavity resonator with ramp shaped supports

A cavity for a hydrogen maser is described consisting of three parts which provide highly stable mechanical and thermal expansion characteristics for the cavity and ease of tuning. The three parts which are made of a glass ceramic material having a very small thermal expansion coefficient (1) a top plate, (2) a cylinder with three interrupted helical ramps at its bottom, and (3) a base which includes a bottom plate and three ramp lugs on which the helical ramps of the cylinder rest when the cylinder is placed on the base with the bottom plate in the cylinder. Cavity tuning is achieved by rotating the cylinder and thereby raising or lowering it on the base, which results in changing the cylinder volume by changing the distance between the bottom and top plates.

Vessot, R. F. C.↗

Sensitivity of Josephson-effect millimeter-wave radiometer

The noise temperature and the minimum detectable temperature of a Josephson junction in video detection of microwave and millimeter-wave radiation has been calculated. We use the well-known method based on a Fokker-Planck equation. The noise temperature can be very close to ambient temperature. Because its predetection bandwidth is very wide, a Josephson-effect radio telescope receiver can have a minimum detectable temperature better than that of a traveling-wave maser.

Ohta, H.↗

New infrared sources associated with H II regions

The H II regions studied have generally been those which contain OH or H2O maser sources and which have been shown to contain compact condensations of ionized gas which may be connected with star formation processes. A brief account of two such sources, W3 and NGC 7538, is given. On the basis of the reported observations it is concluded that in general H II condensations are infrared sources in the range from 3 to 20 microns. The condensations are hidden optically by large quantities of obscuring matter.

Wynn-Williams, C. G.↗

Infrared emission from H II regions

Analysis of observations made at infrared wavelengths of a large number of H II regions. Several types of IR sources are found associated with H II regions, and a single region can contain a number of varied IR emitting objects. The main sources of IR emission are ionized hydrogen concentrations, heated dust particles, and OH/H2O masers. Flux density maps for both radio and IR emission suggest that there is a physical association between the IR and radio-emitting regions. The properties of several H II regions indicate that they may be protostellar objects at various stages of evolution.

Wynn-Williams, C. G.↗

Infrared studies of H II regions and OH sources

This paper presents the observational results of a high spatial-resolution mapping and photometric study in the wavelength range from 1.65 to 20 microns of four H II regions and seven OH sources. Infrared emission indicative of the presence of heated dust was found from the compact H II condensations in W51, DR21, and NGC7538. Infrared emission was also found from the positions of maser sources in NGC 7538, W75(N) W75(S) and Sharpless 269, but not from that in W51. An extended infrared source was found coincident with the peculiar OH source OH 0739-14.

Wynn-Williams, C. G.↗

Accurate positions of OH sources

The Owens Valley interferometer was used at 1665, 1667, and 1720 MHz to measure the positions of eleven OH emission sources. The 1720-MHz OH source in W3 (continuum) was found to be 40 seconds away from the H2O maser source and was found not to coincide with any radio or infrared feature. Two OH emission sources were found in NGC 7538; one is identifiable with a very compact radio infrared source, while the other, 80 seconds to the south, is as yet unidentified. The OH sources 0739-14 and Sharpless 269 also coincide with infrared sources.

Wynn-Williams, C. G.↗

A tracking polarimeter for measuring solar and ionospheric Faraday rotation of signals from deep space probes

A tracking polarimeter implemented on the 64-m NASA/JPL paraboloid antenna at Goldstone, Calif., is described. Its performance is analyzed and compared with measurements. The system was developed to measure Faraday rotation in the solar corona of the telemetry carrier from the Pioneer VI spacecraft as it was occulted by the sun. It also measures rotation in the earth's ionosphere and is an accurate method of determining spacecraft orientation. The new feature of this system is its use of a pair of quarter-wave plates to allow the synthesis of a rotating feed system, while requiring the rotation of only a single section of waveguide. Since the polarization sensing is done at RF and the receiver operates essentially as a null detector, the system's accuracy is superior to other polarization tracking schemes. In addition, the antenna size and maser preamplifier provide unsurpassed sensitivity. The associated instrumentation used in the Pioneer VI experiment is also described.

Ohlson, J. E.↗

Detection of the J = 1 to 0 rotational transition of vibrationally excited silicon monoxide

The v = 1,J = 1 to 0 rotational transition of SiO at 43.1 GHz has been detected in the direction of Becklin's star in the Orion Nebula, and in the M-type star W Hya. In Orion two velocity components are observed, one (the stronger) at a radial velocity of 17 km/sec, the other at -7 km/sec; in W Hya a single line is observed at 39 km/sec. In each case a line at the same radial velocity has been observed at 86.2 GHz in the v = 1,J = 2 to 1 transition, so that the presence of vibrationally excited SiO would seem to be confirmed beyond a reasonable doubt. In the v = 1 state, the photon fluxes of the J = 2 to 1 and 1 to 0 transitions are about equal, suggesting saturated masers occupying the same region of space.

Thaddeus, P.↗

Low-noise K(u)-band receiver input system

Improved maser and superconducting magnet, which operates in vacuum of closed-cycle helium refrigerator, comprise a low-noise, reliable, field-operational receiver input system.

Berwin, R. W.↗

Performance of the new Efratom optically pumped rubidium frequency standards and their possible application in space relativity experiments

The characteristics of Efratom optically pumped rubidium frequency standards are discussed. The Efratom units were compared with cesium beam and hydrogen maser standards and showed a stability of approximately 5 times 10 to the minus 12th power over two one-week periods. Dependency of frequency upon the environmental parameters of pressure, magnetic field, temperature, supply voltage, and acceleration was measured. A package of three units with automatic phase comparison and recording was designed and constructed to allow a measurement of relativistic effects on time with high accuracy during space missions.

Alley, C. O.↗

Time, geodesy, and astrometry: Results from radio interferometry

The results from a total of a dozen transcontinental and intercontinental VLBI experiments are discussed. Particular emphasis is placed on: (1) the inferred behavior of the frequency standards, usually hydrogen masers, on time scales from 10 to 100,000 seconds; (2) the estimated celestial positions of the observed radio sources; (3) the determinations of the vector baselines; and (4) the inferred values of polar motion and UT.1.

Clark, T. A.↗

Bonding of sapphire to sapphire by eutectic mixture of aluminum oxide and zirconium oxide

Bonding of an element comprising sapphire, ruby or blue sapphire to another element of such material with a eutectic mixture of aluminum oxide and zirconium oxide is discussed. The bonding mixture may be applied in the form of a distilled water slurry or by electron beam vapor deposition. In one embodiment the eutectic is formed in situ by applying a layer of zirconium oxide and then heating the assembly to a temperature above the eutectic temperature and below the melting point of the material from which the elements are formed. The formation of a sapphire rubidium maser cell utilizing eutectic bonding is shown.

Deluca, J. J.↗

A review of precision oscillators

Precision oscillators used in PTTI applications include quartz crystal, rubidium gas cell, cesium beam, and hydrogen maser oscillators. A general characterization and comparison of these devices is given including accuracy, stability, environmental sensitivity, size, weight, power consumption, availability and cost. Areas of special concern in practical applications are identified and a projection of future performance specifications is given. An attempt is made to predict physical and performance characteristics of new designs potentially available in the near future.

Hellwig, H.↗

Application of very long baseline interferometry to Astrometry and Geodesy: effects of frequency standard instability on accuracy

The accuracy of geodetic and astrometric information obtained from very long baseline interferometry (VLBI) observations is dependent upon the stability of the frequency standard, or clock, used at each site of VLBI array. The sensitivities of two hydrogen maser frequency standards of different design to pressure, temperature, and magnetic field variations were measured; and, for one of the standards, sensitivity was found to be severe enough to degrade the information content of VLBI measurements. However, the effect on the geometric and astrometric information of such clock instabilities, with time scales of hours or greater, can be sharply reduced through the use of differencing techniques.

Clark, T. A.↗