Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Measuring the NuMI Beam Flux for MINERvA

MINERvA is employing multiple tools to understand its neutrino beam flux. We utilize external hadron production data, but we also depend heavily on in situ techniques in which we reduce our hadron production uncertainties by tuning our Monte Carlo to both MINERvA detector data and muon monitor data.

43 PARTICLE ACCELERATORS↗

SU-F-T-501: Dosimetric Comparison of Single Arc-Per-Beam and Two Arc-Per-Beam VMAT Optimization in the Monaco Treatment Planning System

Purpose: The purpose of this study was to evaluate the dosimetric and practical effects of the Monaco treatment planning system “max arcs-per-beam” optimization parameter in pelvic radiotherapy treatments. Methods: A total of 17 previously treated patients were selected for this study with a range of pelvic disease site including prostate(9), bladder(1), uterus(3), rectum(3), and cervix(1). For each patient, two plans were generated, one using a arc-per-beam setting of ‘1’ and another with setting of ‘2’. The setting allows the optimizer to add a gantry direction change, creating multiple arc passes per beam sequence. Volumes and constraints established from the initial clinical treatments were used for planning. All constraints and dose coverage objects were kept the same between plans, and all plans were normalized to 99.7% to ensure 100% of the PTV received 95% of the prescription dose. We evaluated the PTV conformity index, homogeneity index, total monitor units, number of control points, and various dose volume histogram (DVH) points for statistical comparison (alpha=0.05). Results: We found for the 10 complex shaped target volumes (small central volumes with extending bilateral ‘arms’ to cover nodal regions) that the use of 2 arcs-per-beam achieved significantly lower average DVH values for the bladder V20 (p=0.036) and rectum V30 (p=0.001) while still meeting the high dose target constraints. DVH values for the simpler, more spherical PTVs were not found significantly different. Additionally, we found a beam delivery time reduction of approximately 25%. Conclusion: In summary, the dosimetric benefit, while moderate, was improved over a 1 arc-per-beam setting for complex PTVs, and equivalent in other cases. The overall reduced delivery time suggests that the use of multiple arcs-per-beam could lead to reduced patient on table time, increased clinical throughput, and reduced medical physics quality assurance effort.

60 APPLIED LIFE SCIENCES↗

Shock formation in flowing plasmas by temporally and spatially smoothed laser beams

The cumulative impact of multiple laser speckles on a supersonic plasma flow across optically smoothed laser beams is investigated. The bending of laser beams caused by ponderomotive laser–plasma coupling, together with flow, leads to plasma a momentum-conserving response that results in a deceleration of the flow. Once the flow velocity decreases to a subsonic level, the action of the laser beams can generate a shock within the plasma. This scenario has been predicted theoretically and confirmed by hydrodynamic simulations. The conditions of shock generation are given in terms of the ponderomotive pressure, speckle size, and the flow velocity. The nonlinear properties of the shocks are analyzed using Rankine–Hugoniot relations. According to linear theory, temporally smoothed beams exhibit a higher threshold for shock generation. Numerical simulations with beams that are smoothed by spectral dispersion compare well with the linear theory results, diverging only in the nonlinear regime. The conditions necessary for shock generation and their effects on the laser–plasma coupling in the inertial confinement fusion experiments are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Energy Spread of the Proton Beam in the Fermilab Booster at its Injection Energy

We have measured the energy spread of the Booster beam at its injection energy of 400 MeV by three different methods: (1) creating a notch of about 40 nsec wide in the beam immediately after multiple turn injection and measuring the slippage time required for high and low momentum particles for a grazing touch in line-charge distribution, (2) injecting partial turn beam and letting it to debunch, and (3) comparing the beam profile monitor data with predictions from MAD simulations for the 400 MeV injection beam line. The measurements are repeated under varieties of conditions of rf systems in the ring and in the beam transfer line.

43 PARTICLE ACCELERATORS↗

MCRadar: A Monte Carlo Solver for Cloud and Precipitation Radar

Multiple scattering produces anomalous echoes in observed radar profiles that cannot be explained by other phenomena. These effects are most obvious for spaceborne platforms, at shorter wavelengths, and in convection, as multiple scattering is governed by antenna beam width, optical depth, and albe do; however, multiple scattering has been observed in a range of precipitating conditions. To account for the effects of multiple scattering, Monte Carlo integration is employed in a flexible framework to enable arbitrary radar configurations with finite Gaussian beams for three-dimensional atmospheric scenarios. The three-dimensional nature of the model, coupled with the finite antenna response, also allows for consideration of nonuniform beam filling effects that often coincide with multiple scattering. Examples of airborne and spaceborne radars at various wavelengths are used to illustrate the effects of multiple scattering and nonuniform beam filling. The MCRadar code is currently available in the development version of ARTS.

Adams, Ian Stuart↗

RLGBS: Reinforcement Learning-Guided Beam Search for process optimization in a paper machine dryer section

Paper drying is responsible for over two-thirds of energy consumption in the U.S. pulp and paper industry, presenting significant potential for energy savings through optimization of process parameters. Current approaches often assume fixed operating conditions, neglecting dynamic ambient and process variations that limit achievable savings and real-world applicability. To this end, we develop a physics-based simulation environment for a paper machine dryer section and propose a reinforcement learning (RL) framework to minimize overall energy consumption by optimizing drying process parameters under diverse operating conditions. To mitigate overdrying and numerical instabilities caused by suboptimal local RL actions, we introduce Reinforcement Learning-Guided Beam Search (RLGBS), which explores multiple action sequences in parallel using beam search. Instead of making step-by-step decisions, RLGBS prioritizes solutions based on cumulative probability, reducing the impact of individual suboptimal actions. Experiments demonstrate that RLGBS achieves consistent energy savings under unseen operating conditions not encountered during training, outperforming conventional RL methods. While validated in drying optimization, this framework is broadly applicable to other RL-based industrial process control problems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AN ALMA SURVEY OF SUBMILLIMETER GALAXIES IN THE EXTENDED CHANDRA DEEP FIELD SOUTH: SOURCE CATALOG AND MULTIPLICITY

We present an Atacama Large Millimeter/submillimeter Array (ALMA) Cycle 0 survey of 126 submillimeter sources from the LABOCA ECDFS Submillimeter Survey (LESS). Our 870 {mu}m survey with ALMA (ALESS) has produced maps {approx}3 Multiplication-Sign deeper and with a beam area {approx}200 Multiplication-Sign smaller than the original LESS observations, doubling the current number of interferometrically-observed submillimeter sources. The high resolution of these maps allows us to resolve sources that were previously blended and accurately identify the origin of the submillimeter emission. We discuss the creation of the ALESS submillimeter galaxy (SMG) catalog, including the main sample of 99 SMGs and a supplementary sample of 32 SMGs. We find that at least 35% (possibly up to 50%) of the detected LABOCA sources have been resolved into multiple SMGs, and that the average number of SMGs per LESS source increases with LESS flux density. Using the (now precisely known) SMG positions, we empirically test the theoretical expectation for the uncertainty in the single-dish source positions. We also compare our catalog to the previously predicted radio/mid-infrared counterparts, finding that 45% of the ALESS SMGs were missed by this method. Our {approx}1.''6 resolution allows us to measure a size of {approx}9 kpc Multiplication-Sign 5 kpc for the rest-frame {approx}300 {mu}m emission region in one resolved SMG, implying a star formation rate surface density of 80 M{sub Sun} yr{sup -1} kpc{sup -2}, and we constrain the emission regions in the remaining SMGs to be <10 kpc. As the first statistically reliable survey of SMGs, this will provide the basis for an unbiased multiwavelength study of SMG properties.

79 ASTRONOMY AND ASTROPHYSICS↗

Chemical Free Surface Processing for High Gradient Superconducting RF Cavities

Chemical treatment such as buffered chemical polishing (BCP) or electro polishing (EP) followed by high pressure rinsing (HPR) of niobium (Nb) superconducting RF (SRF) cavities is expensive and complex multistep process. Furthermore, the cavity RF surfaces after the treatment still have numerous bubbles and pits that result from welding. These quench-producing weld defects together with the particulate contamination, result in significant scatter of the multi-cell Nb SRF cavities performance characteristics. This scatter is the major problem in the current manufacturing of the Nb SRF cavities. When developed the chemical free surafce processing using IEB will benefit first J-lab's CEBAF and Fermilab's Project X. Also, light sources, require 1.3 - 1.5 GHz SRF structures. Furthermore, IEB will produce much broader impact because it can be implemented into manufacturing of many other types of RF devices including both superconducting as well as normal conducting RF cavities. This program will develop a new process that will enhance quality of the superconducing radio-frequency cavities and allow acceleration of charged particles to much higher energies. The process also will improve the cavity manufacturing and result in substantial cost reduction of superconducting radio-frequency high-energy particle accelerators. Niobium samples were successfully processed by a DC electron beam to a degree that is suitable for the interior surface of an SRF cavity. To accomplish this, a complete system was developed from the ground up. A vacuum chamber system was acquired and adapted to act as the vessel for performing the Nb processing experiments. An extremely robust high voltage power supply was developed and manufactured to provide the power necessary to drive the multi-kW DC electron gun. A high voltage isolation filament transformer was also designed and manufactured to provide the necessary current to drive the filament within the electron gun. Finally, a beam melt characterization DC electron gun was created. This gun was used to explore the parameter space of interest for processing Nb SRF cavities. The beam melt characterization tests concluded that multiple quick passes at moderate beam power provided the most ideal melt zone characteristics Nb surfaces. It was also found that excellent melt and polish results could be achieved at lower voltages than originally conceived, getting the great results at a beam voltage of 20kV versus the 50kV used in the initial Phase I testing at Jefferson Laboratory. Operating at 20kV will also greatly reduce the challenges of designing a compact DC electron gun for processing of complete Nb SRF cavities, which will be done in Phase III. This final report is divided in eight parts which cover the major investigation work and results which have been performed and achieved. The first part addresses the design, fabrication and testing of the vacuum chamber. In the second part, the DC power supply output circuit design is presented for providing an operating space of 50-60kV with currents from 20-160mA and short and open circuit fault modes are considered and resolved. The third section covers testing and commissioning of the high voltage step up transformer and 150kV isolation transformer. Section four covers the design, construction and performance for a 100kV high voltage bushing. Section number five treats the filament design and load testing. Section number six covers electron gun design and simulation of electron beam melting. Section seven presents the beam target design, assembly and testing and test gun with solenoid magnet, design, fabrication and testing. Finally, section eight demonstrates electron beam melting and polishing of Nb, Cu and SS samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Near-field testing of the 30 GHz TRW proof-of-concept multibeam antenna

Near-field testing was conducted on the 30 GHz TRW proof-of-concept (POC) Multibeam Antenna (MBA). The TRW POC MBA is a dual offset Cassegrain reflector system using a 2.7 m main reflector. This configuration was selected to assess the ability to create both multiple fixed and scanned spot beams. The POC configuration investigated frequency reuse via spatial separation of beams, polarization selectivity and time division multiple access scanning at 30 GHz. Measurements of directivity, sidelobe level, and pattern were made at NASA Lewis Research Center's Near-Field Antenna Test Facility. Presented in this paper are complete results of these measurements. Included is a detailed discussion of all testing procedures and parameters. Results of additional testing used to evaluate diffraction effects of the subreflector and distortions of the main reflector are also presented.

Kunath, R. R., Jr.↗

Multiple Cyclotron Method to Search for CP Violation in the Neutrino Sector

New low-cost, high-power proton cyclotrons open the opportunity for a novel precision search for CP violation in the light neutrino sector. The accelerators can produce decay-at-rest neutrino beams located at multiple distances from a Gd-doped ultralarge water Cherenkov detector in order to search for CP violation in {nu}{sub {mu}{yields}{nu}e} oscillations at short baselines. This new type of search complements presently proposed experiments, providing measurements that could lead to a substantially better exploration of CP violation in the neutrino sector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental study of energy-dependent angular broadening of MeV electron beams for high-resolution imaging in thick samples

In scanning transmission electron microscopy (STEM), spatial resolution is primarily influenced by the projected size of the electron probe within the specimen. In thin samples, a large semi-convergence angle enables a tightly focused beam and sub-nanometer resolution. However, in thick specimens, resolution is fundamentally limited by transverse beam broadening from multiple large-angle scattering events—for example, a probe with 10 mrad angular divergence can broaden by ∼100 nm over a 10 μm path. Since this broadening scales inversely with beam energy, MeV-STEM offers a promising route for high-resolution imaging in thick materials. To quantitatively assess this effect, we performed high-precision measurements at UCLA’s PEGASUS beamline, characterizing beam divergence and intensity profiles for 3–8 MeV electrons transmitted through a wedged-silicon sample of varying thickness. Our results reconcile discrepancies among analytical models and validate Monte Carlo simulations. Here, we find that increasing beam energy from 3.0 to 5.8 MeV reduces angular broadening by a factor of 2.6, with diminishing returns observed at 7.6 MeV. These findings provide a quantitative framework for optimizing MeV-STEM parameters in high-resolution imaging of thick biological and microelectronic specimens, and for guiding beam energy selection in other advanced imaging modes beyond STEM.

36 MATERIALS SCIENCE↗

Glass forming ability of the Mo-Pd system studied by thermodynamic modeling and ion beam mixing

Glass forming ability/range of the Mo-Pd binary metal system was studied by thermodynamic calculations employing Miedema's model and ion beam mixing of multiple metal layers. The thermodynamic calculations predict a narrow composition range of 8-26 at% Pd, within which metallic glass formation is energetically favored, whereas the experimental results showed that ion beam mixing was able to synthesize metallic glasses within a composition range 13-30 at% Pd, which was well in accordance with the prediction. Besides, in the Mo{sub 70}Pd{sub 30} multilayered films, with varying the irradiation dose, a dual-phase metallic glass was formed, and it could be considered as an intermediate state. The possible mechanism for the formation of the metallic glasses was also discussed in terms of the atomic collision theory.

36 MATERIALS SCIENCE↗

Variation of transverse momentum in hadronic collisions

The paper presents a detailed parameterization of the transverse momentum in hadronic collisions on multiplicity and on beam momentum. Hadronic collisions are considered at energies below the ultra-high energy domain, on the basis of an uncertainty relation and a naive eikonal model with an impact-parameter-dependent multiplicity.

Saint Amand, J.↗

Additive Manufacturing for Low Volume Bearings

ORNL worked with the Schaeffler Group USA to explore additive manufacturing techniques that might be appropriate for prototyping of bearing cages. Multiple additive manufacturing techniques were investigated, including e-beam, binder jet and multiple laser based processes. The binder jet process worked best for the thin, detailed cages printed.

36 MATERIALS SCIENCE↗

Post-filamentation propagation of high-power laser pulses in air in the regime of narrowly focused light channels

We report the results of experimental and theoretical studies of the post-filamentation stage of nonlinear propagation of high-power pulsed radiation from a Ti : sapphire laser in air. We have for the first time obtained the experimental dependences of the angular divergence of specific spatially localised high-intensity light structures that are observed in the beam after its multiple filamentation (post-filamentation of channels) when varying the initial focusing of laser radiation and its energy. It is found that the angular divergence of the post-filamentation channels decreases with increasing pulse energy and reducing beam numerical aperture. The experimental dependences are qualitatively interpreted based on the diffraction model of the Bessel – Gaussian beam. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Direct cross section measurement of 102 Pd ⁢(𝛾,𝑝) and 102 Pd ⁢(𝛾,𝛼) for the astrophysical 𝑝 process

Background: A handful of neutron-deficient stable nuclei, known as the “p nuclei,” cannot be produced through astrophysical neutron capture processes. Instead, some of these nuclei are proposed to be produced by 𝛾-induced reactions on existing r- and s-process seeds. The specific astrophysical site or sites are not yet identified, however, with uncertainties in the cross sections of these 𝛾-induced reactions playing a role. Databases of reaction rates for astrophysical simulations often rely on theoretical statistical model calculations, such as Hauser-Feshbach, for rates where no experimental information is known. However, reasonable variations in the choice of parametrizations of various nuclear properties can create order-of-magnitude variations in the final predicted cross sections and reaction rates, which are then propagated through the models to the predicted final abundances. Purpose: To better constrain these statistical model calculations and ultimately reduce the uncertainties from the nuclear physics on our understanding of the p nuclei, a measurement of the cross sections of 𝛾-induced reactions on the p-nucleus 102 Pd was undertaken. This work represents the first measurement of its kind, using segmented silicon detectors to measure prompt charged particle emission from 𝛾-induced reactions. Methods: Quasimonoenergetic gamma beams from the High Intensity 𝛾 Source facility bombarded an enriched 102 Pd target. A segmented silicon array was arranged to detect the particles emitted from (𝛾,𝑝) and (𝛾,𝛼) reactions. Results: Reaction cross sections were deduced at multiple 𝛾-beam energies between 10 and 19 MeV, and compared to statistical model calculations using talys-1.96. The 102 Pd ⁢(𝛾,𝑝)⁢ 101 Rh reaction cross section was reasonably well reproduced by a subset of photon strength functions and level densities, though the strength to the ground state of 101 Rh was underestimated at higher incident gamma energies. The 102 Pd ⁢(𝛾,𝛼)⁢ 98 Ru was in general overpredicted by the various alpha-nucleus optical model potentials. Conclusions: While the theoretical cross sections used to model the (𝛾,𝑝) reactions for the p process may be reasonable, a more careful approach is needed in the case of (𝛾,𝛼). Further work to probe gamma-induced reaction cross sections at and near the p nuclei is warranted.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-G-BRC-05: Conundrum for VMAT Cranial Multiple Lesions Treated with HD120 MLC

Purpose: To commission a custom 6MV-SRS-AAA Eclipse beam model for VMAT multiple lesions cranial SRS treatment on a Varian TrueBeam STx. Methods: Six clinical plans were created using a customized beam model with dosimetric-leaf-gap(DLG) optimized for clinical treatments. Each plan had 4–6 non-isocentric targets with size from 0.2 to 7.1cc. All fields were measured with EBT3 film in the coronal plane in a solid water phantom and with an AS1000 EPID using gantry rotation. In addition, an end-to-end test was performed with coronal and sagittal films in an anthropomorphic phantom verifying dosimetry and localization accuracy. Portal dose distributions were generated with a custom portal dosimetry algorithm(PDIP). Measured dose distributions were compared with calculations using average dose difference (DD), and gamma function, γ. Using a 1.25mm grid, the γ criteria, local DD ≤ 3% and 2mm distance-to-agreement, were applied in regions with dose 50% of maximum. Results: The respective DD and γ for all films were <±2% and >94.2%. The portal dose γ scores for all the plans were >94.9%. However, local regions with underdose >10%, were observed when targets were treated with the 5mm leaves. The same plans re-optimized with two isocenters such that all lesions were under the 2.5mm leaves did not show this effect. The DD and localization error of the end-to-end test were within 3.4% and 1.0mm respectively. Conclusion: The custom AAA beam model is capable of calculating acceptable dosimetry for targets using only the 2.5 mm leaves. This restricts lesions to within ±4cm of isocenter. The observed underdose beneath the 5mm leaves is attributed to a limitation in Eclipse that uses a single DLG representing the DLG’s of both 2.5mm and 5mm leaves. If lesions are >4cm from isocenter, a multiple isocenter technique should be considered to allow the use of only the 2.5mm leaves.

60 APPLIED LIFE SCIENCES↗

SU-D-BRE-03: Dosimetric Impact of In-Air Spot Size Variations for Commissioning a Room-Matched Beam Model for Pencil Beam Scanning Proton Therapy

Purpose: To quantitatively evaluate dosimetric consequence of spot size variations and validate beam-matching criteria for commissioning a pencil beam model for multiple treatment rooms. Methods: A planning study was first conducted by simulating spot size variations to systematically evaluate dosimetric impact of spot size variations in selected cases, which was used to establish the in-air spot size tolerance for beam matching specifications. A beam model in treatment planning system was created using in-air spot profiles acquired in one treatment room. These spot profiles were also acquired from another treatment room for assessing the actual spot size variations between the two treatment rooms. We created twenty five test plans with targets of different sizes at different depths, and performed dose measurement along the entrance, proximal and distal target regions. The absolute doses at those locations were measured using ionization chambers at both treatment rooms, and were compared against the calculated doses by the beam model. Fifteen additional patient plans were also measured and included in our validation. Results: The beam model is relatively insensitive to spot size variations. With an average of less than 15% measured in-air spot size variations between two treatment rooms, the average dose difference was −0.15% with a standard deviation of 0.40% for 55 measurement points within target region; but the differences increased to 1.4%±1.1% in the entrance regions, which are more affected by in-air spot size variations. Overall, our single-room based beam model in the treatment planning system agreed with measurements in both rooms < 0.5% within the target region. For fifteen patient cases, the agreement was within 1%. Conclusion: We have demonstrated that dosimetrically equivalent machines can be established when in-air spot size variations are within 15% between the two treatment rooms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗