Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiplexer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Using mechanistic models and machine learning to design single-color multiplexed nascent chain tracking experiments

mRNA translation is the ubiquitous cellular process of reading messenger-RNA strands into functional proteins. Over the past decade, large strides in microscopy techniques have allowed observation of mRNA translation at a single-molecule resolution for self-consistent time-series measurements in live cells. Dubbed Nascent chain tracking (NCT), these methods have explored many temporal dynamics in mRNA translation uncaptured by other experimental methods such as ribosomal profiling, smFISH, pSILAC, BONCAT, or FUNCAT-PLA. However, NCT is currently restricted to the observation of one or two mRNA species at a time due to limits in the number of resolvable fluorescent tags. In this work, we propose a hybrid computational pipeline, where detailed mechanistic simulations produce realistic NCT videos, and machine learning is used to assess potential experimental designs for their ability to resolve multiple mRNA species using a single fluorescent color for all species. Our simulation results show that with careful application this hybrid design strategy could in principle be used to extend the number of mRNA species that could be watched simultaneously within the same cell. We present a simulated example NCT experiment with seven different mRNA species within the same simulated cell and use our ML labeling to identify these spots with 90% accuracy using only two distinct fluorescent tags. We conclude that the proposed extension to the NCT color palette should allow experimentalists to access a plethora of new experimental design possibilities, especially for cell Signaling applications requiring simultaneous study of multiple mRNAs.

59 BASIC BIOLOGICAL SCIENCES↗

A randomized multiplex CRISPRi-Seq approach for the identification of critical combinations of genes

Identifying virulence-critical genes from pathogens is often limited by functional redundancy. To rapidly interrogate the contributions of combinations of genes to a biological outcome, we have developed a mu ltiplex, r andomized C RISPR i nterference s equencing (MuRCiS) approach. At its center is a new method for the randomized self-assembly of CRISPR arrays from synthetic oligonucleotide pairs. When paired with PacBio long-read sequencing, MuRCiS allowed for near-comprehensive interrogation of all pairwise combinations of a group of 44 Legionella pneumophila virulence genes encoding highly conserved transmembrane proteins for their role in pathogenesis. Both amoeba and human macrophages were challenged with L. pneumophila bearing the pooled CRISPR array libraries, leading to the identification of several new virulence-critical combinations of genes. lpg2888 and lpg3000 were particularly fascinating for their apparent redundant functions during L. pneumophila human macrophage infection, while lpg3000 alone was essential for L. pneumophila virulence in the amoeban host Acanthamoeba castellanii . Thus, MuRCiS provides a method for rapid genetic examination of even large groups of redundant genes, setting the stage for application of this technology to a variety of biological contexts and organisms.

59 BASIC BIOLOGICAL SCIENCES↗

A randomized multiplex CRISPRi-Seq approach for the identification of critical combinations of genes

Identifying virulence-critical genes from pathogens is often limited by functional redundancy. To rapidly interrogate the contributions of combinations of genes to a biological outcome, we have developed a mu ltiplex, r andomized C RISPR i nterference s equencing (MuRCiS) approach. At its center is a new method for the randomized self-assembly of CRISPR arrays from synthetic oligonucleotide pairs. When paired with PacBio long-read sequencing, MuRCiS allowed for near-comprehensive interrogation of all pairwise combinations of a group of 44 Legionella pneumophila virulence genes encoding highly conserved transmembrane proteins for their role in pathogenesis. Both amoeba and human macrophages were challenged with L. pneumophila bearing the pooled CRISPR array libraries, leading to the identification of several new virulence-critical combinations of genes. lpg2888 and lpg3000 were particularly fascinating for their apparent redundant functions during L. pneumophila human macrophage infection, while lpg3000 alone was essential for L. pneumophila virulence in the amoeban host Acanthamoeba castellanii . Thus, MuRCiS provides a method for rapid genetic examination of even large groups of redundant genes, setting the stage for application of this technology to a variety of biological contexts and organisms.

Ellis, Nicole A. (ORCID:0000000195928415)↗

Television multiplexing system

System with single, standard, wideband line transmits ten or more real time TV video data displays over hard wire to recorders more than 22.5 km from source. Digital logic and integrated circuits ensure high reliability and low maintenance. System is adaptable for video sampling applications.

Simpkins, L. G.↗

Doubly multiplexing dispersive spectrometer.

Description of a spectrometer that incorporates 19 entrances and 19 exit slots. The instrument's dual capability to perform either one-dimensional imaging or alternately to give a spectrum with a high SNR over the entire source is shown. The instrument operates in the Littrow mode at f/8. The slot width and length for each mask are 0.625 and 3.5 mm, respectively, giving a total aperture length of 12.1 mm. The corresponding resolving power at 1.7 microns is 230.

Phillips, P. G.↗

Gaussian and click noise in an FM/FM multiplex receiver.

An FM/FM system is one in which the signal information frequency modulates a subcarrier, which, in turn, frequency modulates a main carrier for transmission. The detection process then involves two frequency demodulators in sequence. Using Rice's click model for both FM demodulators, we obtain the average click rate and an approximate output spectrum that include the effect of the impulses generated by the carrier demodulator on the subcarrier demodulation at and below threshold. We then focus on the threshold behavior of these systems and the proportioning of their modulation parameters so as to provide certain desired characteristics. We find that due to the filtering action of the second demodulator, the number of output clicks from carrier generated spikes can be orders of magnitude smaller, yet their contribution to the output noise can be much greater than that produced by the first demodulation.

Stochel, N. H.↗

Data multiplexer using a tree switch

Self-decoding FET-hybrid or integrated-circuit tree configuration uses minimum number of components and can be sequenced by clock or computer. Redundancy features can readily be incorporated into tree configuration; as tree grows in size and more sensors are included, percentage of parts that will affect given percentage of sensors steadily decreases.

Easton, R. A.↗

Frequency division multiplex technique

A system for monitoring a plurality of condition responsive devices is described. It consists of a master control station and a remote station. The master control station is capable of transmitting command signals which includes a parity signal to a remote station which transmits the signals back to the command station so that such can be compared with the original signals in order to determine if there are any transmission errors. The system utilizes frequency sources which are 1.21 multiples of each other so that no linear combination of any harmonics will interfere with another frequency.

Brey, H.↗

Frequency division multiplexer code 04236, serial no. 001, phase 2

Design principles and test results of modifications to two wideband channels, 8 kHz DS located at 44kHz and 16 kHz SSB located at 104 kHz, are given. Data cover power supply modifications, wideband operational amplifiers, trade-off to determine requirements for precision components, printed circuit board layout, applicability of original equipment specification No. 110438, and optimum wideband channel design.

Hauge, G.↗