Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear pulse processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Pulse shape discrimination of Cs 2 LiYCl 6 :Ce 3+ detectors at high count rate based on triangular and trapezoidal filters

Cs 2 LiYCl 6 :Ce 3+ (CLYC) detectors have demonstrated the capability to simultaneously detect γ-rays and thermal and fast neutrons with medium energy resolution, reasonable detection efficiency, and substantially high pulse shape discrimination performance. In this work, a disadvantage of CLYC detectors is the long scintillation decay times, which causes pulse pile-up at moderate input count rate. Pulse processing algorithms were developed based on triangular and trapezoidal filters to discriminate between neutrons and γ-rays at high count rate. The algorithms were first tested using low-rate data. They exhibit a pulse-shape discrimination performance comparable to that of the charge comparison method, at low rate. Then, they were evaluated at high count rate. Neutrons and γ-rays were adequately identified with high throughput at rates of up to 375 kcps. The algorithm developed using the triangular filter exhibits discrimination capability marginally higher than that of the trapezoidal filter based algorithm irrespective of low or high rate. The algorithms exhibit low computational complexity and are executable on an FPGA in real-time. Finally, they are also suitable for application to other radiation detectors whose pulses are piled-up at high rate owing to long scintillation decay times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast, Low Noise Photodetectors for Nuclear Physics

The overall goal of the Phase-II project was to construct and evaluate high performance SSPM technology for nuclear physics experiments. To achieve this overall objective, we first undertook optimization of the SSPM technology. This effort involved further enhancement of the optical quantum efficiency as well as the geometric efficiency (or fill-factor) of the SSPMs, which resulted in improvement of the photodetection efficiency of the SSPMs. Important SSPM parameters such as gain, dark count-rate, cross-talk, temporal response, after-pulsing, quantum efficiency and photodetection efficiency were evaluated for the optimized devices and these parameters were compared with those for Phase-I prototypes. Large area SSPMs (1 to 2 cm 2 ) were built using optimal design parameters. Noise analysis of large area SSPMs was performed. Upon coupling SSPMs to various scintillators (LSO/LYSO, LaBr 3 :Ce, NaI:Tl, LuAG:Ce etc.), energy resolution studies were carried. Timing resolution was also be measured with SSPMs coupled to fast scintillators (such as LaBr 3 :Ce, BaF 2 , LuAG:Ce, plastic and LSO/LYSO) using 511-keV gamma-rays ( 22 Na source). Multi-element SSPM arrays (6 x 6 format with ~1.5 x 1.5 mm 2 elements) were also designed and built using the CMOS process. These SSPM arrays were packaged and appropriate readout electronics was assembled. These SSPM arrays were operated with individual readout of each SSPM element. Large area (~1 cm 2 ) micro-pixel level PS-SSPMs with active and passive components to enable on-chip charge sharing for position sensing were also designed and built. Spatial, energy and timing resolution studies were conducted with the multi-element SSPM arrays as well as PS-SSPMs coupled to segmented scintillation arrays.

99 GENERAL AND MISCELLANEOUS↗

Nanopatterning and tuning of optical taper antenna apex for tip-enhanced Raman scattering performance

This paper focuses on finding optimal electrochemical conditions from linear sweep voltammetry analysis for preparing highly reproducible tip-enhanced Raman scattering (TERS) conical gold tips with dc-pulsed voltage etching. Special attention is given to the reproducibility of tip apex shapes with different etchant mixtures. We show that the fractional Brownian motion model enables a mathematical description of the decaying current kinetics during the whole etching process up to the cutoff event. Further progress in preparation of highly reproducible smooth and sharp tip apexes is related to the effect of an additive, such as isopropanol, to aqueous acids. A finite-difference time-domain method based near-field analysis provides evidence that TERS performance depends critically on tip orientation relative to a highly focused laser beam. A TERS based criterion for recognizing gold tips able to couple/decouple optical near- and far-fields is proposed.

36 MATERIALS SCIENCE↗

Time-interval distributions in a digital gamma multi-channel analyzer at extreme input rates

Here, this study explores the relationship between experimentally observed inter-event time-interval distributions (TIDs) and measured dead times for pulses generated by a HPGe gamma detector and processed by a digital spectrometer. The system utilizes a fast and slow channel, pile-up rejector, trapezoid filtering, and flash analog-to-digital converter. The experimentally derived TIDs were compared with theory for validation. The results demonstrate that the theoretical model reliably describes measured TIDs up to 40% dead time. However, significant distortion effects become increasingly pronounced at higher input rates. It appears that the deviation between the measured and calculated time-interval distributions take the shape of higher-order convolutions of the TID, which represent the time difference between counts for more than two successive events. In this work, theoretical functions for the TID are expanded to reproduce measurements up to 90%. This refinement in the interpretation and treatment of the measured TIDs provides improved accuracy and precision in the prediction of the true event rate and measured dead time in the counter. Even though it reflects occasional count loss that is specific to the set-up, it is expected that a similar adjustment may be applicable to other detection systems as well.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of ion beam space charge compensation with a 4-grid analyzer

Experiments to investigate the space charge compensation of pulsed high-current heavy ion beams are performed at the GSI ion source text benches with a 4-grid analyzer provided by CEA/Saclay. The technical design of the 4-grid analyzer is revised to verify its functionality for measurements at pulsed high-current heavy ion beams. The experimental investigation of space charge compensation processes is needed to increase the performance and quality of current and future accelerator facilities. Measurements are performed directly downstream a triode extraction system mounted to a multi-cusp ion source at a high-current test bench as well as downstream the post-acceleration system of the high-current test injector (HOSTI) with ion energies up to 120 keV/u for helium and argon. At HOSTI, a cold or hot reflex discharge ion source is used to change the conditions for the measurements. The measurements were performed with helium, argon, and xenon and are presented. Results from measurements with single aperture extraction systems are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of the Photoinduced axial ligation process in the excited state of nickel (II) phthalocyanine

Photoinduced axial ligation process in the excited state of nickel(II) octabutoxyphthalocyanine (NiPcOBu8) in pyridine solvent has been investigated by ultrafast optical transient absorption and X-ray transient absorption spectroscopies. Although Ni phthalocyanine complexes have been reported to have no tendency to form sixcoordinate structure, the (d(z2),d(x2-y2)) state of NiPcOBu8 generated by photoexcitation of Q-band was discovered to axially ligate with the pyridine molecule very rapidly, on a timescale of (similar to)100 ps. Although the presence of an excited unligated (d,d) state cannot be confirmed due to the time resolution limit of the synchrotron X-ray probe pulse with (similar to)80 ps FWHM, the biexponential kinetics of the ground state recovery detected by the is 1s -> 4pz feature suggests the decay of the unligated (d,d) species with an 82ps time constant, while that of the ligated NiPcOBu8 species is 3-5 ns. The photoinduced ligation dynamics of NiPcOBu8 is vastly different compared to that of Ni porphyrin complexes. This study provides a structural basis on the ligation chemistry in both the ground and excited states of nickel complexes based on their electronic and nuclear structures.

Excited state structural dynamics↗

Hard X-ray induced fast secondary electron cascading processes in solids

Recent studies confirmed that the materials used in the extreme UV and soft X-ray regime for precise characterization of intense free-electron laser pulses (e.g., Si 3 N 4 ) do not work efficiently in the hard X-ray regime, which is due to the fact that the impact of a hard X-ray photon is followed by a series of electron cascading processes. Following theoretical indication, we show that this limitation can be circumvented and the cascading time can be significantly reduced if the X-ray photon energy is double the ionization energy. We investigate an alternative material for pulse diagnostics, SnO 2 , using the Linac Coherent Light Source at photon energies of 5 keV and 9 keV. We prove the validity of the concept and show that it has a large potential for practical applications. In conclusion, by applying the proposed criteria, the temporal accuracy of the non-invasive pulse diagnostic tools can be improved in current and emerging hard X-ray facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Data Acquisition with GPUs: The DAQ for the Muon $g$-$2$ Experiment at Fermilab

Graphical Processing Units (GPUs) have recently become a valuable computing tool for the acquisition of data at high rates and for a relatively low cost. The devices work by parallelizing the code into thousands of threads, each executing a simple process, such as identifying pulses from a waveform digitizer. The CUDA programming library can be used to effectively write code to parallelize such tasks on Nvidia GPUs, providing a significant upgrade in performance over CPU based acquisition systems. The muon $g$-$2$ experiment at Fermilab is heavily relying on GPUs to process its data. The data acquisition system for this experiment must have the ability to create deadtime-free records from 700 $\mu$s muon spills at a raw data rate 18 GB per second. Data will be collected using 1296 channels of $\mu$TCA-based 800 MSPS, 12 bit waveform digitizers and processed in a layered array of networked commodity processors with 24 GPUs working in parallel to perform a fast recording of the muon decays during the spill. The described data acquisition system is currently being constructed, and will be fully operational before the start of the experiment in 2017.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

National Ignition Facility. Facility and Infrastructure Systems Maintenance Plan

Ensuring the reliability of the NIF, including its support systems, laser systems, target diagnostic systems, and utilities, is essential to the availability of the NIF in its support of NNSA missions. NIF is a key capability in the DOE Stockpile Stewardship Program and supports high energy physics experiments for nuclear weapons, energy, and astrophysics applications. High system reliability provides opportunities for shots and scientific discoveries with opportunities to enhance and upgrade capabilities. This Maintenance Plan (MP) identifies the policies and procedures used to perform and support asset management of the NIF Facility and Infrastructure Systems (FInS), NIF Lasers & Alignment (LASE), NIF Target Experimental Operations (TOPS), NIF Target Area Science and Engineering (TASE), and NIF&PS Control Systems (NCS). The FInS systems include the facility, HVAC, contamination control, beampath, and Line Replaceable Units (LRUs) as well as utilities which create the beampath environments, such as vacuum, argon, or clean dry air. The LASE systems are Programmatic systems which include laser diagnostics, alignment, power conditioning, pulsed power, and input laser systems. The TOPS and TASE systems are also Programmatic systems which include target and diagnostic delivery systems and positioners, many different insertable and fixed target diagnostics, and cryogenic and target gas fill systems. Finally, the NCS systems include both software and hardware for industrial and shot operation control systems. Policies governing administrative and operational practices related to maintenance of FInS, LASE, TOPS, TASE, and NCS systems are described in this plan. In addition, the plan provides processes and procedures for managing, tracking, and documenting the work. This document, the NIF Operations Management Plan, NIF-5020544 (Ref. 1), and NIF Shot Operations Plan, NIF-5018506 (Ref. 2), together satisfy the requirements of the Conduct of Operations. Duties, responsibilities, and reporting requirements of the various positions associated with FInS, LASE, and TOPS maintenance are detailed in this plan. The FInS systems include both Real Property systems with asset management requirements specified in DOE Order 430.1C (Ref. 3) and Programmatic systems. In addition, for FInS, there is a list of the System Level Maintenance Plans (SLMPs) in NIF-1007419198 (Ref. 4) which provide the system descriptions and maintenance plan and schedule. In addition, the list includes the Reliability Centered Maintenance (RCM) and Experience Centered Maintenance (ECM) evaluations that have been performed for applicable FInS systems as well as reliability criticality per Section 3.5. The -AM version of the NIF Maintenance Plan focuses on the reliability program for FInS, LASE, TOPS, TASE, and NCS within the context of the overall NIF Reliability, Availability, and Maintainability (RAM) program and incorporates changes since the -AL version from August 2011 and has been updated to be fully consistent with the updates to Ref. 1. It also includes asset management considerations, updates to the Work Order (WO) process within the NIF Computerized Maintenance Management System (CMMS) which is EAM infor® System Maintenance and Reliability Tracking (SMaRT) (Ref. 5), and updates to metrics and key performance indicators (KPIs).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

'Non-hypotensive' hypovolaemia reduces ascending aortic dimensions in humans

1. The notion that small, 'non-hypotensive' reductions of effective blood volume alter neither arterial pressure nor arterial baroreceptor activity is pervasive in the experimental literature. We tested two hypotheses: (a) that minute arterial pressure and cardiac autonomic outflow changes during hypovolaemia induced by lower body suction in humans are masked by alterations in breathing, and (b) that evidence for arterial baroreflex engagement might be obtained from measurements of thoracic aorta dimensions. 2. In two studies, responses to graded lower body suction at 0 (control), 5, 10, 15, 20 and 40 mmHg were examined in twelve and ten healthy young men, respectively. In the first, arterial pressure (photoplethysmograph), R-R interval, and respiratory sinus arrhythmia amplitude (complex demodulation) were measured during uncontrolled and controlled breathing (constant breathing frequency and tidal volume). In the second, cross-sectional areas of the ascending thoracic aorta were calculated from nuclear magnetic resonance images. 3. Lower body suction with controlled breathing resulted in an increased arterial pulse pressure at mild levels (5-20 mmHg; ANOVA, P < 0.05) and a decreased arterial pulse pressure at moderate levels (40 mmHg; ANOVA, P < 0.05). Both R-R intervals and respiratory sinus arrhythmia were negatively related to lower body suction level, whether group averages (general linear regression, r > 0.92) or individual subjects (orthogonal polynomials, 12 of 12 subjects) were assessed. 4. Aortic pulse area decreased progressively and significantly during mild lower body suction, with 47% of the total decline occurring by 5 mmHg. 5. These results suggest that small reductions of effective blood volume reduce aortic baroreceptive areas and trigger haemodynamic adjustments which are so efficient that alterations in arterial pressure escape detection by conventional means.

NASA Discipline Cardiopulmonary↗

Studies of EMP generation using a Lienard-Wiechert formulation, and progress toward a 3-D EMP code

Here, we describe studies of the generation of electro-magnetic pulse (EMP) fields under the idealized conditions of a delta-function gamma pulse, a spherical cap of Compton electrons located at a common radius from the burst, and the absence of the conduction current. Various processes (geomagnetic rotation, drag, and scattering) contribute to the time derivative of the Compton current density, which appears as the source term in the Lienard–Wiechert expression for the radiation field. These processes are considered separately and in combination, and their influences on the waveform of the EMP assessed. Using a separate computational approach, different numerical models of multiple scattering are tested, in an effort to assess the validity of existing codes and earlier results. We also describe plans for and progress toward a comprehensive 3-D EMP code, which is to employ recently developed numerical methods and is to offer a variety of models, including the Lienard–Wiechert formulation described here.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mg-Ion Conduction in Antiperovskite Solid Electrolytes Revealed by 25 Mg Ultrahigh Field NMR and First-Principles Calculations

Magnesium-ion batteries hold the potential to outperform the energy density of lithium-ion batteries, given the divalent charge carried by each Mg 2+ cation, but remain in an early stage of development. Here, in this study, 25 Mg solid-state nuclear magnetic resonance (ssNMR) is used to gain insight into the local structure and Mg-ion dynamics of candidate Mg-ion solid electrolytes, the antiperovskites Mg 3 SbN and Mg 3 AsN. Using the highest available magnetic field (35.2 T) for high-resolution solid-state NMR, the largest 25 Mg quadrupole coupling constants (C Q ) yet measured of up to 22 MHz are reported and corroborated by first-principles calculations. Predicted C Q values are shown to correlate with the antiperovskite’s tolerance factor; thus, 25 Mg NMR linewidths can report on lattice distortions and phase stability of these antiperovskites. Variable-temperature 25 Mg NMR spectra demonstrate changes at elevated temperatures, ascribed to Mg-ion motional effects. 25 Mg T 1 relaxometry measurements at ultrahigh field reveal a lower activation energy for the more distorted Mg 3 AsN phase, matching computational predictions of a lower energy barrier for Mg 2+ ion migration and suggesting that additional scrutiny of antiperovskites as Mg-ion conductors is warranted. Given the inherent challenges of 25 Mg NMR, this work demonstrates the benefits of combining ultrahigh field NMR spectroscopy, advanced pulse sequences, modern signal processing, and first-principles calculations to facilitate NMR of quadrupolar nuclei as a tool to probe the local structure and ion dynamics in beyond-Li battery materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Test Study for Generation of Short Pulsed Synchrotron Radiation by Kicker Magnet in SPring-8 Storage Ring

A shorter pulse of synchrotron radiation is desired to measure a fast dynamic process exploration with a better resolution by material structure physics users. Among many complex schemes proposed for this purpose, we tested a simple scheme which makes use of a head-tail oscillation of a circulating electron beam with a small beam emittance. We have developed a new kicker magnet system which generated a short pulsed horizontal field of about 4.19 mT in 1.4 {mu}s pulse width with 1 Hz repetition. With this new developed kicker magnet system, we observed a bunch profile which leaned impressively between head and tail position by a visible light streak camera. Then we succeeded in achieving the shorter X-ray pulse width than the original one after a vertical slit being sliced by {approx}6 times. The observed X-ray pulse width was 7.38{+-}2.35 ps in FWHM.

43 PARTICLE ACCELERATORS↗

On a framework for generating PoD curves assisted by numerical simulations

The Probability of Detection (PoD) curve method has emerged as an important tool for the assessment of the performance of NDE techniques, a topic of particular interest to the nuclear industry where inspection qualification is very important. The conventional experimental means of generating PoD curves though, can be expensive, requiring large data sets (covering defects and test conditions), and equipment and operator time. Several methods of achieving faster estimates for PoD curves using physics-based modelling have been developed to address this problem. Numerical modelling techniques are also attractive, especially given the ever-increasing computational power available to scientists today. Here we develop procedures for obtaining PoD curves, assisted by numerical simulation and based on Bayesian statistics. Numerical simulations are performed using Finite Element analysis for factors that are assumed to be independent, random and normally distributed. PoD curves so generated are compared with experiments on austenitic stainless steel (SS) plates with artificially created notches. We examine issues affecting the PoD curve generation process including codes, standards, distribution of defect parameters and the choice of the noise threshold. We also study the assumption of normal distribution for signal response parameters and consider strategies for dealing with data that may be more complex or sparse to justify this. These topics are addressed and illustrated through the example case of generation of PoD curves for pulse-echo ultrasonic inspection of vertical surface-breaking cracks in SS plates.

36 MATERIALS SCIENCE↗

High-speed X-ray imaging pixel array detector for synchrotron bunch isolation

A wide-dynamic-range imaging X-ray detector designed for recording successive frames at rates up to 10 MHz is described. X-ray imaging with frame rates of up to 6.5 MHz have been experimentally verified. The pixel design allows for up to 8–12 frames to be stored internally at high speed before readout, which occurs at a 1 kHz frame rate. An additional mode of operation allows the integration capacitors to be re-addressed repeatedly before readout which can enhance the signal-to-noise ratio of cyclical processes. This detector, along with modern storage ring sources which provide short (10–100 ps) and intense X-ray pulses at megahertz rates, opens new avenues for the study of rapid structural changes in materials. The detector consists of hybridized modules, each of which is comprised of a 500 µm-thick silicon X-ray sensor solder bump-bonded, pixel by pixel, to an application-specific integrated circuit. The format of each module is 128 × 128 pixels with a pixel pitch of 150 µm. In the prototype detector described here, the three-side buttable modules are tiled in a 3 × 2 array with a full format of 256 × 384 pixels. Lastly, we detail the characteristics, operation, testing and application of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Carbon-13 NMR spectra of lignin isolated from field grown transgenic poplar

Here we present a curated dataset of a series of 13C nuclear magnetic resonance (NMR) spectra of lignin isolated from transgenic monolignol 4-O-methyltransferase (MOMT4) engineered poplar. The transgenic poplar was collected from a 3-year field trial experiment. The poplar was Soxhlet-extracted with toluene/ethanol and the extractives-free poplar was then ball-milled in a Retsch PM100 planetary ball mill using a porcelain jar with ceramic balls at 600 rpm for 2 h. The ball-milled materials were then subjected to enzymatic hydrolysis for 48 h followed by centrifugation and washing with deionized water. The solid residue was extracted twice with 96:4 (v/v) 1,4-dioxane/water mixture at room temperature overnight. The extracts were combined, rotary evaporated, and freeze-dried to recover the lignin. The dry lignin samples were dissolved in deuterated dimethyl sulfoxide for NMR characterization. 13C experiments were performed in a Bruker Avance III HD 500 MHz NMR spectrometer operating at a frequency of 125.12 MHz for the 13C nucleus using a standard Bruker pulse sequence (zgpg) on a Prodigy platform cryoprobe. The NMR spectra were acquired under the following conditions: spectra width 229 ppm, 64k data points, 1s pulse delay, and 6k scans. All the data was processed using the Bruker’s TopSpin 3.6 software. Additional meta data is embedded in the raw spectra files.

13C NMR, lignin, poplar, field trial, MOMT4, CBI↗

Light control of intramolecular nuclear dynamics by vortex electron localization

In strong-field ionization of molecules, intense light pulses are thought to have a negligible direct influence on atomic nuclei. Molecular dissociation is thus expected to be determined by the geometrical configuration of the molecular ion at the ionization instant. Contrary to this picture, we observe a counterintuitive electron-proton angular correlation and the formation of proton vortices following strong-field ionization of H 2 molecules by bicircularly polarized two-color laser fields. We explain this phenomenon by the pathway interference and localization of the residual H 2 ⁡+ electron in different angular-momentum states formed in the tail of the driving laser pulse. We validate this interpretation by combining a quantum-mechanical numerical simulation of the field-driven coupled electronic-nuclear dynamics and a semiclassical-trajectory model for the phase accumulation of the laser-driven electronic-nuclear wave packet. Our joint experimental and theoretical study reveals a general picture of vortex electron localization which can be used for controlling molecular-bond breaking with circularly polarized laser fields.

Atomic & molecular processes in external fields↗

A high-efficiency, low-Ĉerenkov Micro-Layered Fast-Neutron Detector for the $\mathrm{TREAT}$ hodoscope

Here this paper presents an enabling technology for high-efficiency fast-neutron detection for the Transient Reactor Test (TREAT) Facility hodoscope. The hodoscope is currently outfitted with 25.4-mm long Hornyak buttons for fast-neutron detection. However, they require improvements, as they suffer from low detection efficiency, Ĉerenkov radiation contaminating the signal, and non-linearity of detector response at large transients. To address these issues, a layered ZnS:Ag device has been constructed. The layered design provides various advantages: it incorporates greater scintillation volume, Ĉerenkov background is significantly reduced by eliminating the need for additional light guides, and the detection process is simplified by achieving gamma-ray rejection using only pulse-height discrimination. The result is a greater number of fast neutron counts with reduced background noise contaminating the signal. On being irradiated with a 252Cf source (whose neutron energy spectrum closely mimics a reactor fission spectrum), a 25.4-mm long layered device was found to exhibit an intrinsic fast-neutron detection efficiency of 8.1% for neutrons with an average energy of 2 MeV, while a 43-mm long device allows for a greater number of fast neutron to be detected, increasing the efficiency to 9.1%. Further lengthening of the device up to 20 cm has been numerically predicted to exhibit even higher efficiencies. The detectors can be mass-produced easily and inexpensively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗