Mariner V temperature control reference design, test, and performance.
Mariner 5 temperature control reference design, test and performance
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Mariner 5 temperature control reference design, test and performance
An SRNL H-Canyon Test Bed performance evaluation project was completed jointly by SRNL and LANL on a prototype monochromatic energy dispersive x-ray fluorescence instrument, the hiRX. A series of uncertainty propagations were generated based upon plutonium and uranium measurements performed using the alpha-prototype hiRX instrument. Data reduction and uncertainty modeling provided in this report were performed by the SRNL authors. Observations and lessons learned from this evaluation were also used to predict the expected uncertainties that should be achievable at multiple plutonium and uranium concentration levels provided instrument hardware and software upgrades being recommended by LANL and SRNL are performed.
Cold performance tests and startup tests were conducted on the Brayton-cycle inverter, motor-driven pump, dc supply, speed control with parasitic load resistor and the Brayton control system. These tests were performed with the components in a vacuum and mounted on coldplates. A temperature range of ?25 to -50 C was used for the tests. No failures occurred, and component performance gave no indication that there would be any problem with the safe operation of the Brayton power generating system.
The testing and performance of a prototype modem developed at NASA Lewis Research Center for high-speed free-space direct detection optical communications is described. The testing was performed under laboratory conditions using computer control with specially developed test equipment that simulates free-space link conditions. The modem employs quaternary pulse position modulation (QPPM) at 325 Megabits per second (Mbps) on two optical channels, which are multiplexed to transmit a single 650 Mbps data stream. The measured results indicate that the receiver's automatic gain control (AGC), phased-locked-loop slot clock recovery, digital symbol clock recovery, matched filtering, and maximum likelihood data recovery circuits were found to have only 1.5 dB combined implementation loss during bit-error-rate (BER) performance measurements. Pseudo random bit sequences and real-time high quality video sources were used to supply 650 Mbps and 325 Mbps data streams to the modem. Additional testing revealed that Doppler frequency shifting can be easily tracked by the receiver, that simulated pointing errors are readily compensated for by the AGC circuits, and that channel timing skew affects the BER performance in an expected manner. Overall, the needed technologies for a high-speed laser communications modem were demonstrated.
A variable inlet guide vane (VIGV) convertible engine that could be used to power future high-speed V/STOL and rotorcraft was tested on an outdoor stand. The engine ran stably and smoothly in the turbofan, turboshaft, and dual (combined fan and shaft) power modes. In the turbofan mode with the VIGV open, fuel consumption was comparable to that of a conventional turbofan engine. In the turboshaft mode with the VIGV closed, fuel consumption was higher than that of present turboshaft engines because power was wasted in churning fan-tip air flow. In dynamic performance tests with a specially built digital engine control and using a waterbrake dynamometer for shaft load, the engine responded effectively to large steps in thrust command and shaft torque.
A variable inlet guide vane (VIGV) convertible engine that could be used to power future high-speed V/STOL and rotorcraft was tested on an outdoor stand. The engine ran stably and smoothly in the turbofan, turboshaft, and dual (combined fan and shaft) power modes. In the turbofan mode with the VIGV open, fuel consumption was comparable to that of a conventional turbofan engine. In the turboshaft mode with the VIGV closed, fuel consumption was higher than that of present turboshaft engines because power was wasted in churning fan-tip air flow. In dynamic performance tests with a specially built digital engine control and using a waterbrake dynamometer for shaft load, the engine responded effectively to large steps in thrust command and shaft torque.
In 2013, a new development began that would put multi-story buildings within the exclusion zone of the 80- by 120- Foot Wind Tunnel (80x120) inlet that exceeded the then existing building height restriction. This raised questions concerning whether the tunnel could operate within the acceptable turbulence limits of ≤ 0.5% in the axial direction over 75% area in the wind tunnel test section. The goal of this testing was to determine the validity of this hypothesis. Testing was performed using the 1/50th-scale model of the 80- by 120-FootWind Tunnel within the full-scale facility test section to characterize the model’s test section turbulence levels as a function of wind direction with the presence of the upwind buildings that are currently being constructed. This paper reports the first testing performed to date on the 80x120 inlet as-built under controlled test conditions for wind magnitude and wind onset direction for a variety of buildings in the inlet external flow field, including no buildings (the control case). This testing determined that, at rated operational conditions the upwind blockages caused no increase in turbulence intensity levels measured in the test section and, in some limited cases, caused the turbulence levels to decrease. Lastly, looking at generic rectangular blockages showed that, to have a discernible effect on test section turbulence levels, scaled 100-ft tall blockages need to be within 600 ft of the existing inlet.
A variable inlet guide van (VIGV) type convertible engine that could be used to power future high-speed rotorcraft was tested on an outdoor stand. The engine ran stably and smoothly in the turbofan, turboshaft, and dual (combined fan and shaft) power modes. In the turbofan mode with the VIGV open fuel consumption was comparable to that of a conventional turbofan engine. In the turboshaft mode with the VIGV closed fuel consumption was higher than that of present turboshaft engines because power was wasted in churning fan-tip airflow. In dynamic performance tests with a specially built digital engine control and using a waterbrake dynamometer for shaft load, the engine responded effectively to large steps in thrust command and shaft torque. Previous mission analyses of a conceptual X-wing rotorcraft capable of 400-knot cruise speed were revised to account for more fan-tip churning power loss than was originally estimated. The new calculations confirm that using convertible engines rather than separate lift and cruise engines would result in a smaller, lighter craft with lower fuel use and direct operating cost.
For one of each of the AVTA's plug-in hybrid electric vehicles, battery electric vehicles, and some hybrid electric vehicles tested in high-mileage courier fleets, the high-voltage traction battery packs were removed from the vehicle and tested at the beginning and end of fleet testing. For some vehicles, batteries also were tested at periodic intervals during fleet testing. Standard reference performance tests were conducted to characterize battery degradation over time. This dataset contains results from two or more rounds of battery tests for 21 distinct year/make/model vehicles (see reference ["INL Advanced Vehicle Testing Activity: On-road Logger and Laboratory Battery Pack Testing Vehicle List"](https://avt.inl.gov/sites/default/files/pdf/reports/DatasetVehicleList.pdf) for full list of vehicles). Each round of battery testing included the "Static Capacity Test" and the "Hybrid Pulse Power Characterization (HPPC) Test", conducted according to test procedures published in the United States Advanced Battery Consortium ["Battery Test Manual For Power-Assist Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=57), ["Battery Test Manual For Plug-In Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=168), and ["Electric Vehicle Battery Test Procedures Manual"](https://www.uscar.org/commands/files_download.php?files_id=5) prior to the time of testing. These tests were performed by Intertek Testing Services, North America. (This dataset will be shared by API; a small sample of the vehicle battery and test data has been extracted and is available for download while the API is being developed.)
For one of each of the AVTA's plug-in hybrid electric vehicles, battery electric vehicles, and some hybrid electric vehicles tested in high-mileage courier fleets, the high-voltage traction battery packs were removed from the vehicle and tested at the beginning and end of fleet testing. For some vehicles, batteries also were tested at periodic intervals during fleet testing. Standard reference performance tests were conducted to characterize battery degradation over time. This dataset contains results from two or more rounds of battery tests for 21 distinct year/make/model vehicles (see reference ["INL Advanced Vehicle Testing Activity: On-road Logger and Laboratory Battery Pack Testing Vehicle List"](https://avt.inl.gov/sites/default/files/pdf/reports/DatasetVehicleList.pdf) for full list of vehicles). Each round of battery testing included the "Static Capacity Test" and the "Hybrid Pulse Power Characterization (HPPC) Test", conducted according to test procedures published in the United States Advanced Battery Consortium ["Battery Test Manual For Power-Assist Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=57), ["Battery Test Manual For Plug-In Hybrid Electric Vehicles"](https://www.uscar.org/commands/files_download.php?files_id=168), and ["Electric Vehicle Battery Test Procedures Manual"](https://www.uscar.org/commands/files_download.php?files_id=5) prior to the time of testing. These tests were performed by Intertek Testing Services, North America. This dataset is shared by API; a small sample of the vehicle battery and test data has been extracted and is also available for download.
Model predictive control (MPC) is a system or process control technique for making decisions under uncertainty via rolling look-ahead optimizations at each control step where only the current step decisions are applied, and the rest are discarded. In this work, we developed an MPC for a critical load restoration (CLR) in power distribution systems to recover system service (electricity delivery) following an extreme event-triggered substation outage. The method considers the problem of controlling distributed energy resources (DERs) of the distribution system with the objective of achieving maximum load pick up while satisfying distribution network flow and voltage constraints. A linearized optimal power flow (OPF) model is employed to represent the physics of the network. The problem formulation is augmented with a ramping (up) reserve product for the DERs to ensure improved and upward monotonic load restoration as time evolves. Simulation analysis and performance tests are performed using a modified IEEE 13-bus test feeder integrated with wind, solar, microturbine, and energy storage battery. The software is developed using various software packages in Julia and Python. The MPC model is implemented using the JuMP optimization language in Julia while the data analytics including renewable generation and load demand forecasts, running the MPC simulation and visualizations is performed in Python.
The Korean government together with the Korean nuclear society completed the development of technologies for the design, manufacturing, and performance verification test of the APR1400's Reactor Coolant Pump (RCP) as one of the national programs for the localization of deficient nuclear technology. The RCP localization program was driven by KAERI, which was responsible for the development of the performance verification and evaluation technology, and by DOOSAN heavy industrial company, which was in charge of the design and manufacturing of the RCP. The test facility for the localized APR1400's RCP was constructed at the KAERI site at the end of 2012. The thermal hydraulic and electric capability of the RCP test facility (RCPTF) covers up to 18.5 MPa, 343 deg. C, 11.7 m{sup 3}/s, and 14.0 MW for the design pressure, temperature, flow rate, and maximum electric power, respectively. In 2013, a commissioning test was performed to verify its designed capability, followed by several modifications in the RCPTF including signal processing and control logic to enhance the verification and evaluation capability of the RCP performance. After finishing the commissioning and modification of the RCPTF, a type test for the new-type of RCP was performed successfully. In 2014 and 2015, eight production tests for the localized RCPs, which will be installed in a commercial nuclear power plant in Korea, were successfully completed. As a final stage of the localization program of the RCP, KAERI will perform a seal LOCA test to verify the leakage characteristics and produce experimental data on the localized seal assembly for a safety analysis during a station black out (SBO) condition. In this summary, several technical issues developed through a series of research processes for a performance verification test of the localized RCP are described.
In a world plagued with improvised explosive devices, drugs and dangerous people, the desire to field technology to protect our police and military is providing a fertile market for the proliferation of protection technologies that range from the unproven to the disproven. The market place is currently being flooded with detection equipment making inflated and inaccurate marketing claims of high reliably, high detection probabilities, and ease of operation - all while offering detection capabilities at safe distances. The manufacturers of these devices have found a willing global marketplace, which includes some of the most dangerous places in the world. Despite a wealth of contradictory performance and testing data available on the Internet, sales of these devices remain brisk and profitable. Rather than enhancing the security of police and military personnel, the reliance on these unproven and disproven devices is creating a sense of false security that is actually lowering the safety of front-line forces in places like Iraq and Afghanistan. This paper addresses the development and distribution history of some of these devices and describes the testing performed by Sandia National Laboratories in Albuquerque, and other reputable testing agencies that illustrate the real danger in using this kind of unproven technology.
GEOS 2 satellite heat transfer pipe performance in test and orbit
Key to the development of advanced hypersonic engines such as those being considered for the National Aerospace Plane (NASP) is the development and evaluation of high temperature, flexible seals that must seal the many feet of gaps between the articulating and stationary engine panels. Recent seal progress made at NASA-Lewis is reviewed in the areas of seal concept maturation, test rig development, and performance tests. A test fixture was built at NASA capable of subjecting candidate 3 ft long seals to engine simulated temperatures (up to 1500 F), pressures (up to 100 psi), and engine wall distortions (up to 0.15 in only 18 in span). Leakage performance test results at high temperatures are presented for an innovative high temperature, flexible ceramic wafer seal. Also described is a joint Pratt and Whitney/NASA planned test program to evaluate thermal performance of a braided rope seal under engine simulated heat flux rates (up to 400 Btu/sq ft s), and supersonic flow conditions. These conditions are produced by subjecting the seal specimen to hydrogen oxygen rocket exhaust that flows tangent to the specimen.
There are two primary regulatory requirements for Panel Closures at the Waste Isolation Pilot Plant (WIPP), the nation's only deep geologic repository for defense related Transuranic (TRU) and Mixed TRU waste. The Federal requirement is through 40 CFR 191 and 194, promulgated by the U.S. Environmental Protection Agency (EPA). The state requirement is regulated through the authority of the Secretary of the New Mexico Environment Department (NMED) under the New Mexico Hazardous Waste Act (HWA), New Mexico Statutes Annotated (NMSA) 1978, chap. 74-4-1 through 74-4-14, in accordance with the New Mexico Hazardous Waste Management Regulations (HWMR), 20.4.1 New Mexico Annotated Code (NMAC). The state regulations are implemented for the operational period of waste emplacement plus 30 years whereas the federal requirements are implemented from the operational period through 10,000 years. The 10,000 year federal requirement is related to the adequate representation of the panel closures in determining long-term performance of the repository. In Condition 1 of the Final Certification Rulemaking for 40 CFR Part 194, the EPA required a specific design for the panel closure system. The U.S. Department of Energy (DOE) Carlsbad Field Office (CBFO) has requested, through the Planned Change Request (PCR) process, that the EPA modify Condition 1 via its rulemaking process. The DOE has also requested, through the Permit Modification Request (PMR) process, that the NMED modify the approved panel closure system specified in Permit Attachment G1. The WIPP facility is carved out of a bedded salt formation 655 meters below the surface of southeast New Mexico. Condition 1 of the Final Certification Rulemaking specifies that the waste panels be closed using Option D which is a combination of a Salado mass concrete (SMC) monolith and an isolation/explosion block wall. The Option D design was also accepted as the panel closure of choice by the NMED. After twelve years of waste handling operations and a greater understanding of the waste and the behavior of the underground salt formation, the DOE has established a revised panel closure design. This revised design meets both the short-term NMED Permit requirements for the operational period, and also the Federal requirements for long-term repository performance. This new design is simpler, easier to construct and has less of an adverse impact on waste disposal operations than the originally approved Option D design. The Panel Closure Redesign is based on: (1) the results of in-situ constructability testing performed to determine run-of-mine salt reconsolidation parameters and how the characteristics of the bedded salt formation affect these parameters and, (2) the results of air flow analysis of the new design to determine that the limit for the migration of Volatile Organic Compounds (VOCs) will be met at the compliance point. Waste panel closures comprise a repository feature that has been represented in WIPP performance assessment (PA) since the original Compliance Certification Application of 1996. Panel closures are included in WIPP PA models principally because they are a part of the disposal system, not because they play a substantive role in inhibiting the release of radionuclides to the outside environment. The 1998 rulemaking that certified WIPP to receive transuranic waste placed conditions on the panel closure design to be implemented in the repository. The revised panel closure design, termed the Run-of-Mine (ROM) Panel Closure System (ROMPCS), is comprised of 30.48 meters of ROM salt with barriers at each end. The ROM salt is generated from ongoing mining operations at the WIPP and may be compacted and/or moistened as it is emplaced in a panel entry. The barriers consist of bulkheads, similar to those currently used in the panels as room closures. A WIPP performance assessment has been completed that incorporates the ROMPCS design into the representation of the repository, and compares repository performance to that achieved with the approved Option D design. Several key physical processes and rock mechanics principles are incorporated into the performance assessment. First, creep closure of the salt rock surrounding a panel entry results in consolidation of the ROM salt emplaced in the entry. Eventually, the ROM salt comprising the ROMPCS will approach a condition similar to intact salt. As the ROM salt reaches higher fractional densities during consolidation, back stress will be imposed on the surrounding rock mass leading to eventual healing of the disturbed rock zone above and below the panel closure. Healing of the disturbed rock zone above and below the ROMPCS reduces the porosity and permeability in those areas. Analysis of the new design demonstrates that: (1) the WIPP continues to meet regulatory compliance requirements when the ROMPCS design is implemented instead of Option D, and (2) there is no impact on the short-term effectiveness of the panel closure to limit the concentration of VOCs at the WIPP site boundary to a fraction of the health-based exposure limits (HBLs) during the operational period. (authors)
This report presents the results of recent investigations into the aerodynamics of simulated runback ice accretion on airfoils. Aerodynamic tests were performed on a full-scale model using a high-fidelity, ice-casting simulation at near-flight Reynolds (Re) number. The ice-casting simulation was attached to the leading edge of a 72-in. (1828.8-mm ) chord NACA 23012 airfoil model. Aerodynamic performance tests were conducted at the ONERA F1 pressurized wind tunnel over a Reynolds number range of 4.7?10(exp 6) to 16.0?10(exp 6) and a Mach (M) number ran ge of 0.10 to 0.28. For Re = 16.0?10(exp 6) and M = 0.20, the simulated runback ice accretion on the airfoil decreased the maximum lift coe fficient from 1.82 to 1.51 and decreased the stalling angle of attack from 18.1deg to 15.0deg. The pitching-moment slope was also increased and the drag coefficient was increased by more than a factor of two. In general, the performance effects were insensitive to Reynolds numb er and Mach number changes over the range tested. Follow-on, subscale aerodynamic tests were conducted on a quarter-scale NACA 23012 model (18-in. (457.2-mm) chord) at Re = 1.8?10(exp 6) and M = 0.18, using low-fidelity, geometrically scaled simulations of the full-scale castin g. It was found that simple, two-dimensional simulations of the upper- and lower-surface runback ridges provided the best representation of the full-scale, high Reynolds number iced-airfoil aerodynamics, whereas higher-fidelity simulations resulted in larger performance degrada tions. The experimental results were used to define a new subclassification of spanwise ridge ice that distinguishes between short and tall ridges. This subclassification is based upon the flow field and resulting aerodynamic characteristics, regardless of the physical size of the ridge and the ice-accretion mechanism.
This report develops a proposal to design and construct a forced convection test loop. A detailed test plan will then be conducted to obtain data on heat transfer, thermodynamic, and corrosion characteristics of the molten salts and fluid-solid interaction. In particular, this report outlines an experimental research and development test plan. The most important initial requirement for heat transfer test of molten salt systems is the establishment of reference coolant materials to use in the experiments. An earlier report produced within the same project highlighted how thermophysical properties of the materials that directly impact the heat transfer behavior are strongly correlated to the composition and impurities concentration of the melt. It is therefore essential to establish laboratory techniques that can measure the melt composition, and to develop purification methods that would allow the production of large quantities of coolant with the desired purity. A companion report describes the options available to reach such objectives. In particular, that report outlines an experimental research and development test plan that would include following steps: •Molten Salts: The candidate molten salts for investigation will be selected. •Materials of Construction: Materials of construction for the test loop, heat exchangers, and fluid-solid corrosion tests in the test loop will also be selected. •Scaling Analysis: Scaling analysis to design the test loop will be performed. •Test Plan: A comprehensive test plan to include all the tests that are being planned in the short and long term time frame will be developed. •Design the Test Loop: The forced convection test loop will be designed including extensive mechanical design, instrument selection, data acquisition system, safety requirements, and related precautionary measures. •Fabricate the Test Loop. •Perform the Tests. •Uncertainty Analysis: As a part of the data collection, uncertainty analysis will be performed to develop probability of confidence in what is measured in the test loop. Overall, the testing loop will allow development of needed heat transfer related thermophysical parameters for all the salts, validate existing correlations, validate measuring instruments under harsh environment, and have extensive corrosion testing of materials of construction.