Search NASA⌕ Search

SEARCH · Search NASA

Results for “plane of array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

ABSOLUTE TIMING OF THE CRAB PULSAR WITH THE INTEGRAL/SPI TELESCOPE

We have investigated the pulse shape evolution of the Crab pulsar emission in the hard X-ray domain of the electromagnetic spectrum. In particular, we have studied the alignment of the Crab pulsar phase profiles measured in the hard X-rays and in other wavebands. To obtain the hard X-ray pulse profiles, we have used six years (2003-2009, with a total exposure of about 4 Ms) of publicly available data of the SPI telescope on-board the International Gamma-Ray Astrophysics Laboratory observatory, folded with the pulsar time solution derived from the Jodrell Bank Crab Pulsar Monthly Ephemeris. We found that the main pulse in the hard X-ray 20-100 keV energy band leads the radio one by 8.18 +- 0.46 milliperiods in phase, or 275 +- 15 mus in time. Quoted errors represent only statistical uncertainties. Our systematic error is estimated to be approx40 mus and is mainly caused by the radio measurement uncertainties. In hard X-rays, the average distance between the main pulse and interpulse on the phase plane is 0.3989 +- 0.0009. To compare our findings in hard X-rays with the soft 2-20 keV X-ray band, we have used data of quasi-simultaneous Crab observations with the proportional counter array monitor on-board the Rossi X-Ray Timing Explorer mission. The time lag and the pulses separation values measured in the 3-20 keV band are 0.00933 +- 0.00016 (corresponding to 310 +- 6 mus) and 0.40016 +- 0.00028 parts of the cycle, respectively. While the pulse separation values measured in soft X-rays and hard X-rays agree, the time lags are statistically different. Additional analysis show that the delay between the radio and X-ray signals varies with energy in the 2-300 keV energy range. We explain such a behavior as due to the superposition of two independent components responsible for the Crab pulsed emission in this energy band.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-T-161: The Effect of Pencil Beam Scanning Gantry Angle Dependent Spot Size Variations On Plan Quality

Purpose: To investigate the effect of spot size variation as function of gantry angle on the quality of treatment plans for pencil beam scanning proton plans. Method: Three homogeneous 26×26×7cm dose volumes with different ranges and SOBPs were delivered on the matrixxPT 2D array at gantry angles of 0 and 270 degrees. The spot size sigma varies by 1.8, 7.8, and 1.4%, for nominal energies of 215, 183, and 103 MeV (Range 29, 22, and 8cm, respectively). The resulting dose planes are compared and evaluated with the gamma index for 2%/2mm and 1%/1mm criteria. Results: Patient specific QA is performed at a gantry angle of 0 degrees. However, beam sigmas vary as function of gantry angle because of the beam optics for each gantry. This will cause differences between the delivered and planned treatment plans. Delivered plans were compared and a gamma pass rate of 96.5% for criteria of 2%/2mm and 91.4% for 1%/1mm were seen for plans with a nominal energy of 183 MeV. For plans with a nominal energy of 103 MeV, gamma pass rates of 97.3% for 2%/2mm and 91.5% for 1%/1mm were seen. For plans with a nominal energy of 215 MeV the pass rate was 99.8% for 1%/1mm between the two gantry angles. Conclusion: Differences in beam sigma of up to 7.8% do not cause significant differences in the dose distribution of different spot size gammas.

60 APPLIED LIFE SCIENCES↗

Design of the polar neutron-imaging aperture for use at the National Ignition Facility

The installation of a neutron imaging diagnostic with a polar view at the National Ignition Facility (NIF) required design of a new aperture, an extended pinhole array (PHA). This PHA is different from the pinhole array for the existing equatorial system due to significant changes in the alignment and recording systems. The complex set of component requirements, as well as significant space constraints in its intended location, makes the design of this aperture challenging. In addition, lessons learned from development of prior apertures mandate careful aperture metrology prior to first use. This paper discusses the PHA requirements, constraints, and the final design. The PHA design is complex due to size constraints, machining precision, assembly tolerances, and design requirements. When fully assembled, the aperture is a 15 mm × 15 mm × 200 mm tungsten and gold assembly. The PHA body is made from 2 layers of tungsten and 11 layers of gold. The gold layers include 4 layers containing penumbral openings, 4 layers containing pinholes and 3 spacer layers. In total, there are 64 individual, triangular pinholes with a field of view (FOV) of 200 μm and 6 penumbral apertures. Each pinhole is pointed to a slightly different location in the target plane, making the effective FOV of this PHA a 700 μm square in the target plane. The large FOV of the PHA reduces the alignment requirements both for the PHA and the target, allowing for alignment with a laser tracking system at NIF.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for PeV Gamma-Ray Emission from the Southern Hemisphere with 5 Yr of Data from the IceCube Observatory

The measurement of diffuse PeV gamma-ray emission from the Galactic plane would provide information about the energy spectrum and propagation of Galactic cosmic rays, and the detection of a pointlike source of PeV gamma-rays would be strong evidence for a Galactic source capable of accelerating cosmic rays up to at least a few PeV. This paper presents several unbinned maximum-likelihood searches for PeV gamma-rays in the Southern Hemisphere using 5 yr of data from the IceTop air shower surface detector and the in-ice array of the IceCube Observatory. The combination of both detectors takes advantage of the low muon content and deep shower maximum of gamma-ray air showers and provides excellent sensitivity to gamma-rays between ~0.6 and 100 PeV. Our measurements of pointlike and diffuse Galactic emission of PeV gamma-rays are consistent with the background, so we constrain the angle-integrated diffuse gamma-ray flux from the Galactic plane at 2 PeV to 2.61 × 10 -19 cm -2 s -1 TeV -1 at 90% confidence, assuming an E -3 spectrum, and we estimate 90% upper limits on pointlike emission at 2 PeV between 10 -21 and 10 -20 cm -2 s -1 TeV -1 for an E -2 spectrum, depending on decl. Furthermore, we exclude unbroken power-law emission up to 2 PeV for several TeV gamma-ray sources observed by the High Energy Spectroscopic System and calculate upper limits on the energy cutoffs of these sources at 90% confidence. We also find no PeV gamma-rays correlated with neutrinos from IceCube's high-energy starting event sample. Lastly, these are currently the strongest constraints on PeV gamma-ray emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Switchable polar spirals in tricolor oxide superlattices

There are increasing evidences that ferroelectric states at the nanoscale can exhibit fascinating topological structures including polar vortices and skyrmions, akin to those observed in the ferromagnetic systems. Here we report the discovery of a new type of polar topological structure, an ordered array of nanoscale spirals, in the PbTiO 3 /BiFeO 3 /SrTiO 3 tricolor ferroelectric superlattice system obtained via phase-field simulations. This polar spiral structure is composed of fine ordered semi-vortex arrays with vortex cores forming a wavy distribution. It is demonstrated that the tricolor system has an ultrahigh Curie temperature of ~1000 K and a temperature of ~800 K for the phase transformation from spiral structure to in-plane orthorhombic domain structure, demonstrating a great thermal stability. The periodicity phase-diagram is constructed, showing multiple phases from inplane domain, polar spiral, and polar vortex to flux-closure with increasing ferroelectric layer thickness. Moreover, the spiral structure has a net in-plane polarization that could be switched by an experimentally-feasible irrotational in-plane field. The switching process involves a metastable vortex state and is fully reversible. This discovery could open up a new routine to design novel multiferroic topological structures with enhanced stability and tunability towards potential future applications in next-generation electronics.

36 MATERIALS SCIENCE↗

Growth temperature effect on the structural and magnetic properties of Fe{sub 3}O{sub 4} films grown by the self-template method

We have investigated the effect of growth temperature on the structure, surface morphology, and magnetic properties of Fe{sub 3}O{sub 4} thin films grown on SrTiO{sub 3}(001) substrates by a self-template method. To eliminate the intermixing of (001) and (111) orientations that usually occurs in spinel films grown on perovskite substrates, a thin self-template layer of (001)-oriented Fe{sub 3}O{sub 4} was deposited on a SrTiO{sub 3}(001) substrate at 400 °C prior to the main film growth at temperatures of up to 1100 °C. Increasing the growth temperature from 400 °C to 1100 °C resulted in greatly improved crystallinity of the Fe{sub 3}O{sub 4} thin films, with the rocking curve width dropping from 1.41° to 0.28°. Surface analysis by atomic force microscopy showed that raising the growth temperature increased the grain size and the surface roughness, ultimately leading to the formation of regular nanopyramid arrays at 1100 °C. The surface roughening and pyramid formation are caused by the dominance of the lowest surface energy spinel (111) crystal facet. The nanopyramids were fully relaxed but still perfectly (001)-oriented in the out-of-plane direction. The largest pyramids had the lowest coercivity due to a reduction of the demagnetization effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Discovery of hard-magnetic domains in two-dimensional arrays of soft-magnetic Fe{sub 3}O{sub 4} nanocubes

In this study, abnormal hard-magnetic domains were discovered in Fe{sub 3}O{sub 4}@C composite material, in which well-ordered 16-nm-sized Fe{sub 3}O{sub 4} cubes were tightly embedded into carbon sheets of tens of nanometers thick. It was found that ca. 40 columns of Fe{sub 3}O{sub 4} nanocubes magnetically self-assembled into a single strip-type domain with perpendicular magnetic anisotropy. More strikingly, remarkable domain misalignments, which were very similar to common edge dislocations among atomic planes in crystal lattices, were clearly observed and termed as “domain dislocation” in this work. The hard-magnetic properties of Fe{sub 3}O{sub 4}@C material, including large coercivity of 2150 Oe, high M{sub R}/M{sub S} value of 0.9, and strong anisotropy energy of 3.772 × 10{sup 5} erg/cm{sup 3}, were further ascertained by carefully designed electromagnetic absorption contrast experiments. It is anticipated that the discovery of hard-magnetic domains and domain dislocations within 2-D arrays of soft-magnetic nanomaterials will shed new light on the development of high-density perpendicular magnetic recording industry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Anchored Clathrate Waters Bind Antifreeze Proteins to Ice

The mechanism by which antifreeze proteins (AFPs) irreversibly bind to ice has not yet been resolved. The ice-binding site of an AFP is relatively hydrophobic, but also contains many potential hydrogen bond donors/acceptors. The extent to which hydrogen bonding and the hydrophobic effect contribute to ice binding has been debated for over 30 years. Here we have elucidated the ice-binding mechanism through solving the first crystal structure of an Antarctic bacterial AFP. This 34-kDa domain, the largest AFP structure determined to date, folds as a Ca{sup 2+}-bound parallel beta-helix with an extensive array of ice-like surface waters that are anchored via hydrogen bonds directly to the polypeptide backbone and adjacent side chains. These bound waters make an excellent three-dimensional match to both the primary prism and basal planes of ice and in effect provide an extensive X-ray crystallographic picture of the AFP{vert_ellipsis}ice interaction. This unobstructed view, free from crystal-packing artefacts, shows the contributions of both the hydrophobic effect and hydrogen bonding during AFP adsorption to ice. We term this mode of binding the 'anchored clathrate' mechanism of AFP action.

08 HYDROGEN↗

Spatial and temporal evaluations of the liquid argon purity in ProtoDUNE-SP

Liquid argon time projection chambers (LArTPCs) rely on highly pure argon to ensure that ionization electrons produced by charged particles reach readout arrays. ProtoDUNE Single-Phase (ProtoDUNE-SP) was an approximately 700-ton liquid argon detector intended to prototype the Deep Underground Neutrino Experiment (DUNE) Far Detector Horizontal Drift module. It contains two drift volumes bisected by the cathode plane assembly, which is biased to create an almost uniform electric field in both volumes. The DUNE Far Detector modules must have robust cryogenic systems capable of filtering argon and supplying the TPC with clean liquid. This paper will explore comparisons of the argon purity measured by the purity monitors with those measured using muons in the TPC from October 2018 to November 2018. A new method is introduced to measure the liquid argon purity in the TPC using muons crossing both drift volumes of ProtoDUNE-SP. For extended periods on the timescale of weeks, the drift electron lifetime was measured to be above 30 ms using both systems. A particular focus will be placed on the measured purity of argon as a function of position in the detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

X-RAY AND RADIO CONSTRAINTS ON THE MASS OF THE BLACK HOLE IN SWIFT J164449.3+573451

Swift J164449.3+573451 is an exciting transient event, likely powered by the tidal disruption of a star by a massive black hole. The distance to the source, its transient nature, and high internal column density serve to complicate several means of estimating the mass of the black hole. Utilizing newly refined relationships between black hole mass, radio luminosity, and X-ray luminosity, and de-beaming the source flux, a weak constraint on the black hole mass is obtained: log(M{sub BH}/M{sub sun}) = 5.5 {+-} 1.1 (1{sigma} confidence). The confidence interval is determined from the current intrinsic scatter in the relation, which includes effects from X-ray variability and accretion modes. This mass range is broad, but it includes low values that are consistent with some variability arguments, and it safely excludes high-mass values where it becomes impossible for black holes to disrupt stars. Future refinements in relationships between black hole mass, radio luminosity, and X-ray luminosity will be able to reduce the uncertainty in related mass estimates by a factor of two, making this technique comparable to estimates based on the M-{sigma} relationship. Possible difficulties in placing such events on the fundamental plane, a potential future test of their suitability, and uncertainties in mass stemming from variable X-ray emission are discussed. As near- and longer-term survey efforts such as Pan-STARRS, LSST, LOFAR, the Square Kilometer Array, and eROSITA begin to detect many tidal disruption events, black hole mass estimates from combined X-ray and radio observations may prove to be very pragmatic.

79 ASTRONOMY AND ASTROPHYSICS↗

A Face-on Accretion System in High-mass Star Formation: Possible Dusty Infall Streams within 100 AU

We report on interferometric observations of a face-on accretion system around the high-mass young stellar object, G353.273+0.641. The innermost accretion system of 100 au radius was resolved in a 45 GHz continuum image taken with the Jansky-Very Large Array. Our spectral energy distribution analysis indicated that the continuum could be explained by optically thick dust emission. The total mass of the dusty system is ∼0.2 M {sub ☉} at minimum and up to a few M {sub ☉} depending on the dust parameters. 6.7 GHz CH{sub 3}OH masers associated with the same system were also observed with the Australia Telescope Compact Array. The masers showed a spiral-like, non-axisymmetric distribution with a systematic velocity gradient. The line-of-sight velocity field is explained by an infall motion along a parabolic streamline that falls onto the equatorial plane of the face-on system. The streamline is quasi-radial and reaches the equatorial plane at a radius of 16 au. This is clearly smaller than that of typical accretion disks in high-mass star formation, indicating that the initial angular momentum was very small, or the CH{sub 3}OH masers selectively trace accreting material that has small angular momentum. In the former case, the initial specific angular momentum is estimated to be 8 × 10{sup 20} (M{sub ∗}/10 M {sub ☉}){sup 0.5} cm{sup 2} s{sup −1}, or a significant fraction of the initial angular momentum was removed outside of 100 au. The physical origin of such a streamline is still an open question and will be constrained by the higher-resolution (∼10 mas) thermal continuum and line observations with ALMA long baselines.

79 ASTRONOMY AND ASTROPHYSICS↗

ZnO/Ag composite nanorod arrays for surface-plasmon-enhanced emission study

The surface plasmon resonance enhanced emission through coupling of surface plasmons and exciton band energies is studied in hybrid ZnO/Ag nanostructure. The catalytic growth of ZnO nanorods is controlled in seed mediated growth by altering size distribution of Ag nanoislands. X-ray diffraction shows a predominant (002) crystal plane confirming the preferential growth of ZnO nanorods on as-deposited Ag. Increase of surface roughness in Ag film by post deposition annealing process enhances the light emission due to momentum matching between surface plasmons and excitons as well as a red shift of 32 meV occurs due to multi phonon and phonon-exciton interaction.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Novel Deployment of Elpasolites as a Dual Neutron/Gamma-Ray Directional Detector

At a time when upholding national security has never been more important, there exists a need for the advancement of radiation detection technologies. Neutron and photon detectors are essential to fulfilling mission areas including detection and localization of missing, stolen or smuggled radiological or nuclear materials, quantification of the effects of a radiological or nuclear event, and supporting nonproliferation efforts. The aim of this study was to evaluate a new radiation detector based on the scintillation elpasolite compound Cs 2 LiYCl 6 :Ce (CLYC) for simultaneous measurements of neutron and photon flux and the localization of radiation sources. Previous studies performed on the CLYC scintillator indicate its potential for thermal neutron and gamma-ray measurements. This study is dedicated to the novel application of the CLYC as a dual neutron / photon detector and as part of a directional detection system. Both computational modeling and an experimental study were carried out within this research project. As part of the computational study, the response of a CLYC scintillator detector to gamma rays induced by thermal neutron interaction with Cl and 7 Li nuclei was investigated using the MCNP6 code. In addition, arrays of three and four CLYC detectors were modeled in order to evaluate the directional detection of both a thermal neutron source and a gamma-ray source. It was shown that little or no quality of source direction determination would be lost when three detectors were used in the array compared to four detectors. In the experimental study, the photon spectroscopy capabilities of the CLYC detectors were evaluated. A gamma-ray energy resolution of 4.9% was measured for the 662-keV peak of 137 Cs and 3.6% for the 1.33-MeV peak of 60 Co. Using a thermal neutron source, the pulse shape discrimination analysis was successfully performed for the CLYC detector signal waveforms. Thermal neutrons and gamma rays were separated with an exceptional figure of merit (FOM) of 2.3. An array of three CLYC detectors was assembled for the purpose of directional neutron / gamma-ray detection. The intrinsic peak efficiency of CLYC detectors was evaluated. The three-CLYC detector array was deployed for directional measurements with a single gamma-ray 137 Cs source, two gamma-ray sources of 137 Cs and 60 Co isotopes and a thermal neutron source designed using a 239PuBe neutron source supplied with a polyethylene moderator. Measurements were carried out using sources located in the longitude and latitude planes over the angles from 0° to 360°. The measured data were processed through a maximum likelihood estimation algorithm providing a possible direction for which the radioactive source in each case was positioned. The estimated directions were close if not exact matches for the actual directions to the radioactive source. The largest discrepancy in direction produced by the algorithm was approximately 11%. However, it was hypothesized that this percent error can be decreased by homogenizing the directional detection system to consist of scintillators of the same size and quality, identical photomultiplier tubes and identical aluminum housings. The feasibility of this hypothesis to decrease the percent error was confirmed by the zero percent error achieved in the directional measurements produced in the computational study utilizing a homogenous directional detection system. The results of computational and experimental studies completed within this research project provide means to propose the array of three CLYC scintillators as an efficient dual neutron / gamma-ray directional detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Isomeric states in neutron-deficient A{approx}80-90 nuclei populated in the fragmentation of {sup 107}Ag

The relativistic projectile fragmentation of a 750 MeV per nucleon beam of {sup 107}Ag was used to populate isomeric states in neutron-deficient nuclei around A=80-90. Reaction products were separated and unambiguously identified using the GSI FRagment Separator (FRS) and its ancillary detectors. At the final focal plane, the fragments were slowed from relativistic energies by means of an aluminium degrader and implanted in a passive stopper in the center of the high-efficiency, high-granularity Stopped Rare Isotope Spectroscopic INvestigation at GSI (RISING) germanium array. This allowed the identification of excited states in the N=Z nuclei {sub 43}{sup 86}Tc and, for the first time, {sub 41}{sup 82}Nb. Isomeric states have also been identified for the first time in {sup 87,88}Tc, and a previously unreported isomer was observed in {sup 84}Nb. Experimental results are presented along with a discussion on the structure of these nuclei based on interpretations provided by several theoretical models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

EGS Collab Experiment 1: In-situ observation of pre-, co- and post-seismic shear slip preceding hydraulic fracturing

Understanding the initiation and arrest of earthquakes is one of the long-standing challenges of seismology. Here we report on direct observations of borehole displacement by a meter-sized shear rupture induced by pressurization of metamorphic rock at 1.5 km depth. We observed the acceleration of sliding, followed by fast co-seismic slip and a transient afterslip phase. Total displacements were about 7, 5.5 and 9.5 micrometers, respectively for the observed pre-slip, co-seismic slip and afterslip. The observed pre-slip lasted about 0.4 seconds. Co-seismic slip was recorded by the 1 kHz displacement recording and a 12-component array of 3-C accelerometers sampled at 100 kHz. The observed afterslip is consistent with analytical models of arrest in a velocity-strengthening region and subsequent stress relaxation. The observed slip vector agrees with the activation of a bedding plane within the phyllite, which is corroborated by relocated seismic events that were observed during the later stages of the injection experiment. This submission includes the pressure and deformation data recorded by the SIMFIP probe during the first injection at the 164 ft (50 m) notch of borehole E1-I. The injection was performed on on 05/22/2018 as part of Experiment 1 of the EGS Collab project. This data accompanies a manuscript submitted to GRL, linked in this submission.

15 GEOTHERMAL ENERGY↗

The EBEX Balloon-borne Experiment—Optics, Receiver, and Polarimetry

The E and B Experiment (EBEX) was a long-duration balloon-borne cosmic microwave background (CMB) polarimeter that flew over Antarctica in 2012. We describe the experiment's optical system, receiver, and polarimetric method and discuss their in-flight performance. EBEX had three frequency bands centered on 150, 250, and 410 GHz. To make effective use of limited mass and space, we created a 115 cm 2 sr high-throughput optical system that had two ambient temperature mirrors and four antireflection-coated polyethylene lenses per focal plane. All frequency bands shared the same optical train. Polarimetry was achieved with a continuously rotating achromatic half-wave plate (AHWP) that was levitated with a superconducting magnetic bearing (SMB). This is the first use of an SMB in astrophysics. Rotation stability was 0.45% over a period of 10 hr, and angular position accuracy was 0$^{°}_{.}$1. The measured modulation efficiency was above 90% for all bands. To our knowledge the 109% fractional bandwidth of the AHWP was the broadest implemented to date. The receiver, composed of one lens and the AHWP at a temperature of 4 K, the polarizing grid and other lenses at 1 K, and the two focal planes at 0.25 K, performed according to specifications, giving focal plane temperature stability with a fluctuation power spectrum that had a 1/f knee at 2 mHz. EBEX was the first balloon-borne instrument to implement technologies characteristic of modern CMB polarimeters, including high-throughput optical systems, and large arrays of transition edge sensor bolometric detectors with multiplexed readouts.

polarization↗

Modeling dislocations in a polycrystal using the generalized finite element method.

Modeling the interaction of dislocations with internal boundaries and free surfaces is essential to understanding the effect of material microstructure on dislocation motion. However, discrete dislocation dynamics methods rely on infinite domain solutions of dislocation fields which makes modeling of heterogeneous materials difficult. A finite domain dislocation dynamics capability is under development that resolves both the dislocation array and polycrystalline structure in a compatible manner so that free surfaces and material interfaces are easily treated. In this approach the polycrystalline structure is accommodated using the GFEM, and the displacement due to the dislocation array is added to the displacement approximation. Shown in figure 1 are representative results from simulations of randomly placed and oriented dislocation sources in a cubic nickel polycrystal. Each grain has a randomly assigned (unique) material basis, and available glide planes are chosen accordingly. The change in basis between neighboring grains has an important effect on the motion of dislocations since the resolved shear on available glide planes can change dramatically. Dislocation transmission through high angle grain boundaries is assumed to occur by absorption into the boundary and subsequent nucleation in the neighboring grain. Such behavior is illustrated in figure 1d. Nucleation from the vertically oriented source in the bottom right grain is due to local stresses from dislocation pile-up in the neighboring grain. In this talk, the method and implementation is presented as well as some representative results from large scale (i.e., massively parallel) simulations of dislocation motion in cubic nano-domain nickel alloy. Particular attention will be paid to the effect of grain size on polycrystalline strength.

36 MATERIALS SCIENCE↗

In-situ observation of pre-, co- and post-seismic shear slip at 1.5 km depth

Understanding the initiation and arrest of earthquakes is one of the long-standing challenges of seismology. Here we report on direct observations of borehole displacement by a meter-sized shear rupture induced by pressurization of metamorphic rock at 1.5 km depth. We observed the acceleration of sliding, followed by fast co-seismic slip and transient afterslip. Total displacements were about 7, 5.5 and 9.5 micrometers, respectively for the observed pre-slip, co-seismic slip and afterslip. The observed pre-slip lasted about 0.4 seconds. Co-seismic slip was recorded by the 1 kHz displacement recording and a 12-component array of 3-C accelerometers sampled at 100 kHz. The observed afterslip is consistent with analytical models of arrest in a velocity-strengthening region and subsequent stress relaxation. < p >The observed slip vector agrees with the activation of a bedding plane within the phyllite, which is corroborated by relocated seismic events that were observed during the later stages of the injection experiment.

Schoenball, Martin↗