Search NASA⌕ Search

SEARCH · Search NASA

Results for “precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Electroweak precision observables and Higgs-boson signal strengths in the Standard Model and beyond: present and future

We present results from a state-of-the-art fit of electroweak precision observables and Higgs-boson signal-strength measurements performed using 7 and 8 TeV data from the Large Hadron Collider. Based on the HEPfit package, our study updates the traditional fit of electroweak precision observables and extends it to include Higgs-boson measurements. As a result we obtain constraints on new physics corrections to both electroweak observables and Higgs-boson couplings. We present the projected accuracy of the fit taking into account the expected sensitivities at future colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precision and accuracy of magnetic resonance imaging for lobar classification of benign prostatic hyperplasia

Purpose: To validate the application of a magnetic resonance imaging (MRI)-based lobar classification of benign prostatic hyperplasia (BPH) for use in research and clinical management. Methods: Two radiologists with 5 and 11 years post-fellowship experience were trained in the lobar classification of BPH using an internally developed atlas of prostate anatomy with example MRI images edited by a third senior radiologist designated as the “administrator” of the study. A study population of 140 patients referred to a tertiary academic medical center with known or suspected prostate cancer was selected by the administrator to test the interrater reliability (IRR; precision) of the classification as well as accuracy of the two readers compared to the administrator as the “gold” standard. The intrarater reliability of repeat readings of the administrator was also examined. Percentage of agreement, proportion of agreement, and Cohen’s κ were applied. This was a retrospective IRB-approved study. Results: IRR (precision) between the two interpreting radiologists was 64% agreement, corresponding to unweighted κ of 0.52. Composite proportion of agreement across all BPH types (categories) for interpreting radiologists was 0.67. Observer accuracy was 62% agreement, unweighted κ 0.49, for observer 1 and 67%, unweighted κ 0.58, for observer 2. Intrarater reliability for the administrator was 87% agreement, unweighted κ 0.81 with composite proportion of agreement across all categories of 0.87. Conclusions: MRI lobar classification of BPH is a reproducible and reliable tool for research and clinical applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Solving the 3d Ising Model with the Conformal Bootstrap II. c -Minimization and Precise Critical Exponents

Here, we use the conformal bootstrap to perform a precision study of the operator spectrum of the critical 3d Ising model. We conjecture that the 3d Ising spectrum minimizes the central charge \(c\) in the space of unitary solutions to crossing symmetry. Because extremal solutions to crossing symmetry are uniquely determined, we are even able to precisely reconstruct the first several \(\mathbb {Z}_2\) -even operator dimensions and their OPE coefficients. We observe that a sharp transition in the operator spectrum occurs at the 3d Ising dimension \(\Delta _\sigma = 0.518154(15)\) , and find strong numerical evidence that operators decouple from the spectrum as one approaches the 3d Ising point. We compare this behavior to the analogous situation in 2d, where the disappearance of operators can be understood in terms of degenerate Virasoro representations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

New loading method for high precision Sm isotope analysis of nuclear materials using thermal ionization mass spectrometry

This work demonstrates an analytical protocol for high precision Sm isotope analysis by thermal ionization mass spectrometry (TIMS) using a Pt activator. Here, the method permits precise measurements of small aliquots (1–20 ng) of Sm on single Re filament using a modified static-total evaporation technique. This study represents the first attempt to use such protocols for Sm isotope analyses while reducing the loading size of Sm for TIMS. The method could potentially be deployed to study geological, meteorites and lunar samples containing low Sm concentrations, to monitor neutron irradiation exposure based on 149,150 Sm, or to measure Sm isotopic composition in other types of nuclear samples.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

High-precision measurements of half-lives for 69 Ge, 73 Se, 83 Sr, 85 mSr, and 63 Zn radionuclides relevant to the astrophysical p-process via photoactivation at the Madison Accelerator Laboratory

The ground state half-lives of 69 Ge, 73 Se, 83 Sr, 63 Zn, and the half-life of the 1/2 - isomer in 85 Sr have been measured with high precision using the photoactivation technique at an unconventional bremsstrahlung facility that features a repurposed medical electron linear accelerator. The γ -ray activity was counted over about 6 half-lives with a high-purity germanium detector, enclosed into an ultra low-background lead shield. The measured half-lives are: T 1/2 ( 69 Ge) = 38.82 ± 0.07 (stat) ± 0.06 (sys) h; T 1/2 ( 73 Se) = 7.18 ± 0.02 (stat) ± 0.004 (sys) h; T 1/2 ( 83 Sr) = 31.87 ± 1.16 (stat) ± 0.42 (sys) h; T 1/2 ( 85m Sr) = 68.24 ± 0.84 (stat) ± 0.11 (sys) min; T 1/2 ( 63 Zn) = 38.71 ± 0.25 (stat) ± 0.10 (sys) min. These high-precision half-life measurements will contribute to a more accurate determination of corresponding ground-state photoneutron reaction rates, which are part of a broader effort of constraining statistical nuclear models needed to calculate stellar nuclear reaction rates relevant for the astrophysical p -process nucleosynthesis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The precise time-dependent solution of the Fokker–Planck equation with anomalous diffusion

We study the time behavior of the Fokker–Planck equation in Zwanzig’s rule (the backward-Ito’s rule) based on the Langevin equation of Brownian motion with an anomalous diffusion in a complex medium. The diffusion coefficient is a function in momentum space and follows a generalized fluctuation–dissipation relation. We obtain the precise time-dependent analytical solution of the Fokker–Planck equation and at long time the solution approaches to a stationary power-law distribution in nonextensive statistics. As a test, numerically we have demonstrated the accuracy and validity of the time-dependent solution. - Highlights: • The precise time-dependent solution of the Fokker–Planck equation with anomalous diffusion is found. • The anomalous diffusion satisfies a generalized fluctuation–dissipation relation. • At long time the time-dependent solution approaches to a power-law distribution in nonextensive statistics. • Numerically we have demonstrated the accuracy and validity of the time-dependent solution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precision protection through indirect correlations

The dynamics of the quantum Fisher information of the parameters of the initial atomic state is studied, in the framework of open quantum systems, for a pair of static two-level atoms coupled to a bath of fluctuating vacuum scalar fields. Our results show that the correlations between the two atoms as well as the precision limit in quantum metrology are determined by the separation between the two atoms. Remarkably, when the separation between the two atoms approaches zero, the quantum Fisher information, thus the precision limit of the estimation of the parameters of the initial atomic state will be survived from the vacuum fluctuations after long time evolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Software for precise tracking of cell proliferation

Highlights: Black-Right-Pointing-Pointer We developed software for analyzing cultured cells that divide as well as migrate. Black-Right-Pointing-Pointer The active contour model (Snakes) was used as the core algorithm. Black-Right-Pointing-Pointer The time backward analysis was also used for efficient detection of cell division. Black-Right-Pointing-Pointer With user-interactive correction functions, the software enables precise tracking. Black-Right-Pointing-Pointer The software was successfully applied to cells with fluorescently-labeled nuclei. -- Abstract: We have developed a multi-target cell tracking program TADOR, which we applied to a series of fluorescence images. TADOR is based on an active contour model that is modified in order to be free of the problem of locally optimal solutions, and thus is resistant to signal fluctuation and morphological changes. Due to adoption of backward tracing and addition of user-interactive correction functions, TADOR is used in an off-line and semi-automated mode, but enables precise tracking of cell division. By applying TADOR to the analysis of cultured cells whose nuclei had been fluorescently labeled, we tracked cell division and cell-cycle progression on coverslips over an extended period of time.

60 APPLIED LIFE SCIENCES↗

Highly efficient one-step scarless protein tagging by type IIS restriction endonuclease-mediated precision cloning

Protein tagging with a wide variety of epitopes and/or fusion partners is used routinely to dissect protein function molecularly. Frequently, the required DNA subcloning is inefficient, especially in cases where multiple constructs are desired for a given protein with unique tags. Additionally, the generated clones have unwanted junction sequences introduced. To add versatile tags into the extracellular domain of the transmembrane protein THSD1, we developed a protein tagging technique that utilizes non-classical type IIS restriction enzymes that recognize non-palindromic DNA sequences and cleave outside of their recognition sites. Our results demonstrate that this method is highly efficient and can precisely fuse any tag into any position of a protein in a scarless manner. Moreover, this method is cost-efficient and adaptable because it uses commercially available type IIS restriction enzymes and is compatible with the traditional cloning system used by many labs. Therefore, precision tagging technology will benefit a number of researchers by providing an alternate method to integrate an array of tags into protein expression constructs.

60 APPLIED LIFE SCIENCES↗

Atomically precise synthesis of oxides with hybrid molecular beam epitaxy

Advancements in synthesis science are revolutionizing the way we create atomically precise materials. Techniques like molecular beam epitaxy (MBE) have set the benchmark for addressing long-standing questions in materials science by leveraging improved control over the composition and structure of existing materials and enabling materials discovery. In this review, we discuss recent innovations in MBE that are redefining its capabilities, enabling the fabrication of ultra-pure, defect-engineered films and the stabilization of metastable phases that were previously unattainable. These advancements are unlocking new opportunities in electronic, magnetic, and quantum technologies, where the precise tuning of material properties is essential for advancing device functionality and performance.

complex oxides↗

High precision strike point control to support experiments in the DIII-D small angle slot divertor

Improvements in strike point control enabled tests with the new Small Angle Slot (SAS) divertor installed at DIII-D with precision as tight as ±1 mm, barring brief perturbations from ELMs. Aside from being narrower than previous baffle structures in DIII-D, simulations indicate that performance of the SAS divertor should be very sensitive to strike point position, making the improved strike point control essential for experiments with the SAS divertor. Improved control entails regulating more divertor geometry target locations than before and setting higher gain on the strike point target. This is achieved by tasking more poloidal field (PF) shaping coils with divertor topology control, fine tuning of the coil configuration and algorithm gains, and adding regulation of the power supply common rail. Here, the result is that although more variables are controlled, precision is better: high frequency jitter in the strike point position is lower on average compared to related discharges with standard divertor shape control.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resonance ionization mass spectrometry for precise measurements of iostope ratios.

Resonance ionization mass spectrometry offers extremely high sensitivity and elemental selectivity in microanalysis, but the isotopic precision attainable by this technique has been limited. Measured isotope ratios are sensitive to small fluctuations in the pointing, pulse timing, and wavelength of the resonance lasers. We show that, by minimizing these fluctuations using feedback controls and by power-broadening the optical transitions, we are able to measure chromium isotope ratios with statistics-limited precision better than 1%. Small additional improvements in reproducibility come from careful shaping of the electric field in the region where atoms are photoionized and from minimizing pulse-to-pulse variations in the time-of-flight mass spectrometer through which the photoions travel. The increased reproducibility of isotopic measurements on standard materials has enabled us to detect anomalous chromium isotopic abundances in presolar SiC grains extracted from primitive meteorites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatial Precision in Magnetic Resonance Imaging–Guided Radiation Therapy: The Role of Geometric Distortion

Because magnetic resonance imaging–guided radiation therapy (MRIgRT) offers exquisite soft tissue contrast and the ability to image tissues in arbitrary planes, the interest in this technology has increased dramatically in recent years. However, intrinsic geometric distortion stemming from both the system hardware and the magnetic properties of the patient affects MR images and compromises the spatial integrity of MRI-based radiation treatment planning, given that for real-time MRIgRT, precision within 2 mm is desired. In this article, we discuss the causes of geometric distortion, describe some well-known distortion correction algorithms, and review geometric distortion measurements from 12 studies, while taking into account relevant imaging parameters. Eleven of the studies reported phantom measurements quantifying system-dependent geometric distortion, while 2 studies reported simulation data quantifying magnetic susceptibility–induced geometric distortion. Of the 11 studies investigating system-dependent geometric distortion, 5 reported maximum measurements less than 2 mm. The simulation studies demonstrated that magnetic susceptibility–induced distortion is typically smaller than system-dependent distortion but still nonnegligible, with maximum distortion ranging from 2.1 to 2.6 mm at a field strength of 1.5 T. As expected, anatomic landmarks containing interfaces between air and soft tissue had the largest distortions. The evidence indicates that geometric distortion reduces the spatial integrity of MRI-based radiation treatment planning and likely diminishes the efficacy of MRIgRT. Better phantom measurement techniques and more effective distortion correction algorithms are needed to achieve the desired spatial precision.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-precision measurement of U-Pu-Np-Am concentrations and isotope ratios in environmental reference materials by mass spectrometry

Herein, we report results of precise and sensitive mass spectrometric measurements of uranium, plutonium, neptunium, and americium concentrations and isotope ratios in a variety of environmental reference materials. Most of our work has been done on NIST SRM 4350b, River Sediment, but we also present results for NIST SRM 4354, Lake Sediment; NIST SRMs 4355 and 4355a, Peruvian Soil; NIST SRM 4357, Ocean Sediment; NIST SRM 1648a, Urban Particulate Material; NIST SRM 1649b, Urban Dust; IAEA CRM 385, Ocean Sediment; USGS BCR-2, Columbia River Basalt; and USGS BHVO-2, Hawaiian Volcanic Observatory Basalt. These materials reflect a wide range in long-lived actinide concentrations (e.g. 1E4 to 1E10 atoms 239 Pu/g) and isotope ratios. Measurements were performed in a clean laboratory by isotope dilution, multi-collector thermal ionization and multi-collector inductively coupled plasma mass spectrometry. In general, our results are in agreement with, but lower the uncertainty of, literature or certificate values for these reference materials. Our uranium results for the basalts also confirm previously reported high-precision mass spectrometric results from our laboratory. In many cases our measurements of U-Pu-Np-Am nuclides appear to be novel.

58 GEOSCIENCES↗

Digital atomic scale fabrication an inverse Moore's Law – A path to atomically precise manufacturing

There is an exciting opportunity to start a second digital revolution that will supersede the first digital revolution in information technology (IT) as the primary driver of scientific, technological, and economic growth. This new revolution will be digital fabrication technology. Here, the digital IT revolution has been largely driven by digital algorithms such as error detection and correction and Moore's Law which has given us an exponential trend in product capabilities. However, the longstanding trend in improving manufacturing precision which has enabled Moore's Law simply cannot be continued much longer because we are running into the limits imposed by the quantized nature of matter. At this scale, matter can no longer be treated in an analogue fashion i.e. as an infinitely divisible medium, but must be treated as an integer number of discrete atomic distances, i.e. in a digital fashion. By embracing this digital nature of matter, we can conceive of a digital fabrication technology, where the digital processes are the making and breaking of chemical bonds, there is a digital address grid that is spatial in nature, and error detection and correction processes can be developed. This digital fabrication technology will have the similarly huge advantages over analog fabrication that digital IT has over analog IT. We remind the reader that effective digital technologies are not exclusively digital in their operation. Digital electronics is carried out by analog transistors that are embedded in circuitry designed to accept their output in a digital fashion. Digital fabrication technology is not synonymous with Atomically Precise Manufacturing (APM) but should lead to that important capability. Furthermore this digital fabrication technology will start a new exponential manufacturing trend that will replace Moore's law and will not be just for information processing and therefore will have an even larger impact than Moore's Law. Like any exponential trend Digital Fabrication will start slowly in a few niche markets, but the time for investing in the development of this new technology is now.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A Precise Measurement of Reactor Antineutrino at RENO

RENO is the reactor experiment to measure the neutrino mixing angle θ{sub 1}3 by observing the disappearance of the reactor antineutrino. Antineutrinos from six reactors at Yonggwang Nuclear Power Plant in Korea, are detected and compared by two identical detectors located at 294 m and 1383 m, respectively, from the center of the reactor array. The far (near) detector observes 73 (780) electron antineutrino candidate events per day after background subtraction with the precise measurement of reactor antineutrino flux. In this paper, an updated result is presented about the energy spectra of antineutrino signals in RENO detectors. A precise measurement of reactor antineutrino flux is also presented in comparison with expectations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-precision Measurement of the 16 O($n, n'γ$) Cross Section using $γ$-ray Detection in Liquid Scintillators with H 2 O and BeO Targets

The 16 O($n, n'γ$) reaction was measured at the Los Alamos Neutron Science Center white neutron source using γ-ray detection in liquid scintillators present in the upper hemisphere of the Correlated Gamma-Neutron Array for sCattering (CoGNAC). Separate measurements of this reaction were performed using H 2 O and BeO targets in successive years. The unique high energies of γ rays emitted from the 16 O($n, n'γ$) reaction facilitated a clean selection of this reaction from threshold to 9.8 MeV incident neutron energy without the need for precise measurements of the γ-ray energy or the scattered neutrons. The precise time resolution of the liquid scintillator detectors was then exploited to obtain high-resolution incident neutron energy measurements, and good agreement was obtained between the H 2 O and BeO results reported here. The dominant literature data sets for this reaction have systematic differences between them, but the present results improve upon the neutron energy resolution of earlier measurements and show important discrepancies in recent data. Finally, tentative data are also shown up to 20 MeV incident neutron energy but are potentially subject to improved understanding of the relative γ-ray and α decay branches from 16 O excited states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nuclear Targets for a Precision Measurement of the Neutral Pion Radiative Width

A technique is presented for precision measurements of the area densities, density * T, of approximately 5% radiation length carbon and 208Pb targets used in an experiment at Jefferson Laboratory to measure the neutral pion radiative width. The precision obtained in the area density for the carbon target is +/- 0.050%, and that obtained for the lead target through an x-ray attenuation technique is +/- 0.43%.

43 PARTICLE ACCELERATORS↗