Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantum modulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Precise modulation of laser radiation by an acousto-optic modulator for stabilisation of the Nd : YAG laser on optical resonances in molecular iodine

A system of precise frequency modulation of laser radiation by an acousto-optic modulator, which makes it possible to stabilise the radiation power and simultaneously suppress the residual amplitude modulation to a level of 10{sup -8} of the total laser power at the third harmonic of modulation frequency (∼500 Hz), is presented. The use of this system for the Nd : YAG/I{sub 2} optical frequency standard and application of digital signal synthesis and processing methods provided a level of frequency standard instability as small as ∼10{sup -15} for ∼6 × 10{sup 4} s. (frequency standards)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Polarization analysis by off-axis digital holography with an improved optical system and an evaluation of its performance by simulation

An optical system of off-axis digital holography for imaging the Jones vector of an object wave is improved, and a Faraday rotator for the reference wave is also newly constructed. To evaluate the accuracy of the polarization analysis, quarter- and half-wave plates are used as the object, and the distribution of the polarization state of the transmitted light is analyzed for various orientations of the wave plates. The polarization analysis is also simulated, and the effect of a finite value of the extinction ratio and the modulation error for the reference wave is investigated numerically.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High Efficiency Thermoelectric Materials and Devices

Growth of thermoelectric materials in the form of quantum well super-lattices on three-dimensionally structured substrates provide the means to achieve high conversion efficiency of the thermoelectric module combined with inexpensiveness of fabrication and compatibility with large scale production. Thermoelectric devices utilizing thermoelectric materials in the form of quantum well semiconductor super-lattices grown on three-dimensionally structured substrates provide improved thermoelectric characteristics that can be used for power generation, cooling and other applications..

Kochergin, Vladimir↗

Amplifying Magnetic Field Effects on Upconversion Emission via Molecular Qubit-Driven Triplet–Triplet Annihilation

Triplet-triplet annihilation (TTA) enables photon upconversion by combining two lower-energy triplet excitons to produce a higher-energy singlet exciton. This mechanism enhances light-harvesting efficiency for solar energy conversion and enables the use of lower-energy photons in bioimaging and photoredox catalysis applications. The magnetic modulation of such high-energy excitons presents an exciting opportunity to develop molecular quantum information technologies. While the spin dynamics of triplet exciton pairs are sensitive to external magnetic fields, the magnetic field effects (MFEs) associated with these pairs are generally limited by spin statistics to at most 10% at low fields (<1 Tesla), making them challenging to apply in technological advancements. In contrast, MFEs on spin-correlated radical pairs (SCRPs) can be significantly greater, surpassing those on triplet pairs. By using SCRPs-based molecular qubits as triplet sensitizers in the sensitized TTA scheme, we can magnetically modulate TTA and consequently, the delayed fluorescence of annihilators. In our current system, we have achieved more than 70% magnetic modulation of delayed fluorescence, effectively harnessing and even amplifying magnetic modulation within SCRPs to influence high-energy excitons. In conclusion, this work opens new opportunities for advancing spin-controlled chemical reactions and molecular quantum information technologies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multifrequency source for pumping CPT-resonances based on an external cavity diode laser

We report the results of studying operation regimes for an external-cavity diode laser in which the intermode interval corresponds to the clock transition frequency under modulation of the injection current by an rf oscillator, which provides multifrequency pumping of CPT-resonances. (frequency standards)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Goos-Hänchen-like shift in biased silicene

We have theoretically studied the Goos-Hänchen-like shift of spinor-unpolarized beams tunneling through various gate-biased silicene nanostructures. Following the stationary-phase method, lateral displacement in single-, dual-, and multiple-gated silicene systems has been systematically demonstrated. It is shown for simple single-gated silicene that lateral displacement can be generally enhanced by Fabry-Perot interference, and near the transition point turning on the evanescent mode a very large lateral shift could be observed. For the dual-gated structure, we have also shown the crucial role of localized modes like quantum well states in enhancing the beam lateral displacement, while for the multiple gate-biased systems the resulting superlattice subbands are also favorable for lateral displacement enhancement. Importantly, including the degeneracy-broken mechanisms such as gate-field and magnetic modulations, a fully spinor-resolved beam can be distinguished from the rest counterparts by aligning the incident beam with a proper spinor-resolved transition point, localized state, and subband, all of which can be flexibly modulated via electric means, offering the very desirable strategies to achieve the fully spinor-polarized beam for functional electronic applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spinbox: tools for many-body quantum systems in a Monte Carlo context

Spinbox is a piece of software that facilitates quantum mechanical calculations relevant to Monte Carlo simulation of atomic nuclei. At the front lines of research on the nuclear many-body problem are a large number of supercomputer-scale simulation codes. These codes produce valuable results but can be hard to understand, especially for those without intimate knowledge of the relevant theoretical methods. Thus, tools that fill pedagogical roles are extremely valuable. Spinbox makes it easy for one to replicate and analyze the computational processes relevant to a Quantum Monte Carlo (QMC) simulation that may be difficult to understand/debug/analyze due to the scale of the corresponding simulation software. Spinbox is written in Python using other state-of-the-art Python modules for numerical calculations. While a number of Python libraries exist that are suited to general quantum many-body calculations, the motivation of Spinbox is quite particular. In Diffusion Monte Carlo methods (DMC, GFMC, AFDMC), the central calculation is the imaginary-time propagation of individual samples of the many-body wavefunction. Although quantum wavefunctions generally must be described by a probability distribution over a basis, DMC imbues particles (within one sample) with classical spatial coordinates. This method is unusual, so other Python packages are typically not set up to do this easily. Furthermore, the software has built-in options for nuclear systems assuming isospin symmetry, which can be set up with other libraries but is a nontrivial process to do so. Features: - numerical representation of samples of the many-body wavefunctions, including tensor-product states (used in AFDMC) - numerical representation of many-body operators, including tensor-product operators: general, spin, imaginary-time propagation, etc. - the correct associated arithmetic and algebra, implemented as class methods - classes for representing realistic nuclear two- and three-body Hamiltonians (e.g. Argonne V18, Illinois NNN) - large-scale parallel integration over random variables, crucial for the AFDMC method My goal is to make this package open source so that anyone may use it and contribute to it, particularly other researchers doing AFDMC calculations

Fox, Jordan↗

Atomic resolution scanning transmission electron microscopy at liquid helium temperatures for quantum materials

Fundamental quantum phenomena in condensed matter, ranging from correlated electron systems to quantum information processors, manifest their emergent characteristics and behaviors predominantly at low temperatures. This necessitates the use of liquid helium (LHe) cooling for experimental observation. Atomic resolution scanning transmission electron microscopy combined with LHe cooling (cryo-STEM) provides a powerful characterization technique to probe local atomic structural modulations and their coupling with charge, spin and orbital degrees-of-freedom in quantum materials. However, achieving atomic resolution in cryo-STEM is exceptionally challenging, primarily due to sample drifts arising from temperature changes and noises associated with LHe bubbling, turbulent gas flow, etc. In this work, we demonstrate atomic resolution cryo-STEM imaging at LHe temperatures using a commercial side-entry LHe cooling holder. Firstly, we examine STEM imaging performance as a function of He gas flow rate, identifying two primary noise sources: He-gas pulsing and He-gas bubbling. Secondly, we propose two strategies to achieve low noise conditions for atomic resolution STEM imaging: either by temporarily suppressing He gas flow rate using the needle valve or by acquiring images during the natural warming process. Lastly, we show the applications of image acquisition methods and image processing techniques in investigating structural phase transitions in Cr 2 Ge 2 Te 6 , CuIr 2 S 4 , and CrCl 3 . In conclusion, our findings represent an advance in the field of atomic resolution electron microscopy imaging for quantum materials and devices at LHe temperatures, which can be applied to other commercial side-entry LHe cooling TEM holders.

36 MATERIALS SCIENCE↗

Basic Requirements of Spin-Flip Raman Scattering on Excitonic Resonances and Its Modulation through Additional High-Energy Illumination in Semiconductor Heterostructures

We describe the major requirements to experimentally perform and observe resonant spin-flip Raman scattering on excitonic resonances in low-dimensional semiconductors. We characterize in detail the properties of this resonant light scattering technique and evaluate the criteria, which must be fulfilled by the experimental setup and the semiconductor sample studied to be able to observe a spin-flip scattering process. We also demonstrate the influence of additional unpolarized laser illumination with energies, which exceed considerably the band gap energy of the semiconductor nanostructure under study, on the resonantly excited electron spin-flip scattering in InAs-based quantum dot ensembles as well as on the paramagnetic Mn-ion spin-flip in (Zn,Mn)Se/(Zn,Be)Se quantum wells.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cross-Kerr-effect induced by coupled Josephson qubits in circuit quantum electrodynamics

We propose a scheme for implementing cross-Kerr nonlinearity between two superconducting transmission line resonators (TLRs) via their interactions with a coupler constructed by two superconducting transmon qubits connected to each other through a superconducting quantum interference device. When suitably driven, the coupler can induce very strong cross phase modulation (XPM) between the two TLRs due to its N-type level structure and the consequent electromagnetically induced transparency in its lowest states. The flexibility of our design can lead to various inter-TLR coupling configurations. The obtained cross-Kerr coefficient is large enough to allow many important quantum operations in which only few photons are involved. We further show that this scheme is very robust against fluctuations in solid-state quantum circuits. Our numerical calculations imply that the absorption and the dispersion of the TLRs resulting from the decoherence of the coupler are very small compared with the proposed XPM strength.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of the absorbance bleaching in AllnAs/AlGaInAs multiple-quantum wells for semiconductor saturable absorbers.

Semiconductor saturable absorbers (SESAs) introduce loss into a solid-state laser cavity until the cavity field bleaches the absorber producing a high-energy pulse. Multiple quantum wells (MQWs) of AlGaInAs grown lattice-matched to InP have characteristics that make them attractive for SESAs. The band gap can be tuned around the target wavelength, 1064 nm, and the large conduction band offset relative to the AlInAs barrier material helps reduces the saturation fluence, and transparent substrate reduces nonsaturable losses. We have characterized the lifetime of the bleaching process, the modulation depth, the nonsaturable losses, and the saturation fluence associated with SESAs. We compare different growth conditions and structure designs. These parameters give insight into the quality of the epitaxy and effect structure design has on SESA performance in a laser cavity. AlGaInAs MQWs were grown by MOVPE using a Veeco D125 machine using methyl-substituted metal-organics and hydride sources at a growth temperature of 660 C at a pressure of 60 Torr. A single period of the basic SESA design consists of approximately 130 to 140 nm of AlInAs barrier followed by two AlGaInAs quantum wells separated by 10 nm AlInAs. This design places the QWs near the nodes of the 1064-nm laser cavity standing wave. Structures consisting of 10-, 20-, and 30-periods were grown and evaluated. The SESAs were measured at 1064 nm using an optical pump-probe technique. The absorbance bleaching lifetime varies from 160 to 300 nsec. The nonsaturable loss was as much as 50% for structures grown on n-type, sulfur-doped InP substrates, but was reduced to 16% when compensated, Fe-doped InP substrates were used. The modulation depth of the SESAs increased linearly from 9% to 30% with the number of periods. We are currently investigating how detuning the QW transition energy impacts the bleaching characteristics. We will discuss how each of these parameters impacts the laser performance.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Computational models of direct and indirect X‐ray breast imaging detectors for in silico trials

Abstract Background To facilitate in silico studies that investigate digital mammography (DM) and breast tomosynthesis (DBT), models replicating the variety in imaging performance of the DM and DBT systems, observed across manufacturers are needed. Purpose The main purpose of this work is to develop generic physics models for direct and indirect detector technology used in commercially available systems, with the goal of making them available open source to manufacturers to further tweak and develop the exact in silico replicas of their systems. Methods We recently reported on an in silico version of the SIEMENS Mammomat Inspiration DM/DBT system using an open‐source GPU‐accelerated Monte Carlo x‐ray imaging simulation code (MC‐GPU). We build on the previous version of the MC‐GPU codes to mimic the imaging performances of two other Food and Drug Administration (FDA)‐approved DM/DBT systems, such as Hologic Selenia Dimensions (HSD) and the General Electric Senographe Pristina (GSP) systems. In this work, we developed a hybrid technique to model the optical spread and signal crosstalk observed in the GSP and HSD systems. MC simulations are used to track each x‐ray photon till its first interaction within the x‐ray detector. On the other hand, the signal spread in the x‐ray detectors is modeled using previously developed analytical equations. This approach allows us to preserve the modeling accuracy offered by MC methods in the patient body, while speeding up secondary carrier transport (either electron–hole pairs or optical photons) using analytical equations in the detector. The analytical optical spread model for the indirect detector includes the depth‐dependent spread and collection of optical photons and relies on a pre‐computed set of point response functions that describe the optical spread as a function of depth. To understand the capabilities of the computational x‐ray detector models, we compared image quality metrics like modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE), simulated with our models against measured data. Please note that the purpose of these comparisons with measured data would be to gauge if the model developed as part of this work could replicate commercially used direct and indirect technology in general and not to achieve perfect fits with measured data. Results We found that the simulated image quality metrics such as MTF, NNPS, and DQE were in reasonable agreement with experimental data. To demonstrate the imaging performance of the three DM/DBT systems, we integrated the detector models with the VICTRE pipeline and simulated DM images of a fatty breast model containing a spiculated mass and a calcium oxalate cluster. In general, we found that the images generated using the indirect model appeared more blurred with a different noise texture and contrast as compared to the systems with direct detectors. Conclusions We have presented computational models of three commercially available FDA‐approved DM/DBT systems, which implement both direct and indirect detector technology. The updated versions of the MC‐GPU codes that can be used to replicate three systems are available in open source format through GitHub.

Sengupta, Aunnasha↗

Yield Analysis and Comparison of GaInP/Si and GaInP/GaAs Multi-Terminal Tandem Solar Cells

We present a yield analysis of tandem devices consisting of GaInP top cells on Si or GaAs bottom cells with different terminal configurations. Inputs are the I-V and external quantum efficiency of the individual subcells and the irradiance-dependent module temperature of the bottom cell. Our model calculates the temperature of the tandem module by taking into account the performance, spectral working range and luminescent coupling of the different tandem devices, enabling an irradiance- and weather-dependent yield analysis for these modules. We apply the model to compare two types of two junction devices, a GaInP/GaAs monolithically grown tandem device, and a GaInP top cell stacked on a Si bottom cell, the present two best dual junction devices. When the subcells are series connected both technologies perform equally well. The performance of the GaInP/Si can be significantly improved relatively by 5.8% using 3-terminal (3T) devices with a back-contacted bottom cell instead of a 2T configuration, showing a possible benefit when using Si back contacted cells. For GaInP/Si, the 3T-device works as well as the 4T-device, enabling the integration of monolithic tandem cells into modules at comparably high efficiencies.

14 SOLAR ENERGY↗

Enhanced ferromagnetism in monolayer Cr 2 Te 3 via topological insulator coupling

Exchange-coupled interfaces are pivotal in exploiting two-dimensional (2D) ferromagnetism. Due to the extraordinary correlations among charge, spin, orbital and lattice degrees of freedom, layered magnetic transition metal chalcogenides (TMCs) bode well for exotic topological phenomena. Here we report the realization of wafer-scale Cr 2 Te 3 down to monolayer (ML) on insulating SrTiO 3 (111) and/or Al 2 O 3 (001) substrates using molecular beam epitaxy. Robust ferromagnetism persists in the 2D limit. In particular, the Curie temperature T C of 2 ML Cr 2 Te 3 increases from 100 K to ∼120 K when proximitized to topological insulator (TI) (Bi,Sb) 2 Te 3 , with substantially boosted magnetization as observed via polarized neutron reflectometry. Our experiments and theory strongly indicate that the Bloembergen–Rowland interaction is likely universal underlying T C enhancement in TI-coupled magnetic heterostructures. The topological-surface-enhanced magnetism in 2D TMC enables further exchange coupling physics and quantum hybrid studies, including paving the way to realize interface-modulated topological electronics.

36 MATERIALS SCIENCE↗

Strain-tuning of domain walls in multilayer graphene probed in the quantum Hall regime

Domain walls, topological defects that define the frontier between regions of different stacking order in multilayer graphene, have proved to host exciting physics. The ability to tune these topological defects in situ in an electronic transport experiment brings a wealth of possibilities in terms of fundamental understanding of domain walls as well as for electronic applications. Here, we demonstrate, through a MEMS (microelectromechanical system) actuator and magnetoresistance measurements, the effect of domain walls in multilayer graphene quantum Hall effect. Reversible and controlled uniaxial strain triggers the topological defects, manifested as addtional quantum Hall effect plateaus as well as a discrete and reversible modulation of the current across the device. Furthermore, our findings are supported by theoretical calculations and constitute indication of the in situ tuning of topological defects in multilayer graphene probed through electronic transport, opening the way for the use of reversible topological defects in electronic applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Imaging performance of an amorphous selenium digital mammography detector in a breast tomosynthesis system

In breast tomosynthesis a rapid sequence of N images is acquired when the x-ray tube sweeps through different angular views with respect to the breast. Since the total dose to the breast is kept the same as that in regular mammography, the exposure used for each image of tomosynthesis is 1/N. The low dose and high frame rate pose a tremendous challenge to the imaging performance of digital mammography detectors. The purpose of the present work is to investigate the detector performance in different operational modes designed for tomosynthesis acquisition, e.g., binning or full resolution readout, the range of view angles, and the number of views N. A prototype breast tomosynthesis system with a nominal angular range of {+-}25 deg. was used in our investigation. The system was equipped with an amorphous selenium (a-Se) full field digital mammography detector with pixel size of 85 {mu}m. The detector can be read out in full resolution or 2x1 binning (binning in the tube travel direction). The focal spot blur due to continuous tube travel was measured for different acquisition geometries, and it was found that pixel binning, instead of focal spot blur, dominates the detector modulation transfer function (MTF). The noise power spectrum (NPS) and detective quantum efficiency (DQE) of the detector were measured with the exposure range of 0.4-6 mR, which is relevant to the low dose used in tomosynthesis. It was found that DQE at 0.4 mR is only 20% less than that at highest exposure for both detector readout modes. The detector temporal performance was categorized as lag and ghosting, both of which were measured as a function of x-ray exposure. The first frame lags were 8% and 4%, respectively, for binning and full resolution mode. Ghosting is negligible and independent of the frame rate. The results showed that the detector performance is x-ray quantum noise limited at the low exposures used in each view of tomosynthesis, and the temporal performance at high frame rate (up to 2 frames per second) is adequate for tomosynthesis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Physical evaluation of a needle photostimulable phosphor based CR mammography system

Purpose: Needle phosphor based computed radiography (CR) systems promise improved image quality compared to powder phosphor based CR units for x-ray screening mammography. This paper compares the imaging performance of needle CR cassettes, powder based CR cassettes and a well established amorphous selenium (a-Se) based flat panel based mammography system, using consistent beam qualities. Methods: Detector performance was assessed using modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE). Mammography system performance was assessed against levels from the European Guidelines, including threshold gold thickness (c-d), relative signal difference to noise (SdNR) and mean glandular dose, for automatic exposure control settings suggested by the manufacturers. The needle based Agfa HM5.0 CR detector was compared against the single sided readout Agfa MM3.0R and dual sided readout Fuji Profect CS powder CR plates using a 28 kV Mo/Rh spectrum, while a 28 kV W/Rh spectrum was used to compare the Agfa HM5.0 against the Siemens MAMMOMAT Inspiration a-Se based system. Results: MTF at 5 mm{sup -1} was 0.16 and 0.24 for the needle CR detector in the fast and slow scan directions, respectively, indicating a slight improvement ({approx}20%) over the two powder CR systems but remained 50% lower than the result at 5 mm{sup -1} for the a-Se detector ({approx}0.55). Structured screen noise was lower for the needle phosphor compared to the powder plates. CR system gain, estimated from the measured absorption fraction and NNPS results, was 6.3 for the (single sided) needle phosphor and 5.1 and 7.2 for the single sided and dual sided powder phosphor systems. Peak DQE at {approx}100 {mu}Gy was 0.47 for the needle system compared to peak DQE figures of 0.33 and 0.46 for the single sided readout powder plates and dual sided readout plates. The high frequency DQE (at 5 mm{sup -1}) was 0.19 for the needle CR plates, a factor of approximately 3 greater than for the powder CR plates. At 28 kV W/Rh, 2 mm Al, peak DQE for the needle CR system was 0.45 against a value of 0.50 for the a-Se detector. The needle CR detector reached the Acceptable limit for 0.1 mm details in the European Guidelines at a mean glandular dose (MGD) of approximately 1.31 mGy imaged at 28 kV Mo/Rh, compared to figures of 2.19 and 1.43 mGy for the single sided and dual sided readout powder CR systems. The a-Se detector could reach the limit at 0.65 mGy using a 28 kV W/Rh spectrum, while the needle CR system required 1.09 mGy for the same spectrum. Conclusions: Imaging performance for the needle CR phosphor technology, characterized using MTF and DQE and threshold gold thickness demonstrated a clear improvement compared to both single and dual sided reading powder phosphor based CR systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cascaded systems analysis of photon counting detectors

Purpose: Photon counting detectors (PCDs) are an emerging technology with applications in spectral and low-dose radiographic and tomographic imaging. This paper develops an analytical model of PCD imaging performance, including the system gain, modulation transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). Methods: A cascaded systems analysis model describing the propagation of quanta through the imaging chain was developed. The model was validated in comparison to the physical performance of a silicon-strip PCD implemented on an experimental imaging bench. The signal response, MTF, and NPS were measured and compared to theory as a function of exposure conditions (70 kVp, 1–7 mA), detector threshold, and readout mode (i.e., the option for coincidence detection). The model sheds new light on the dependence of spatial resolution, charge sharing, and additive noise effects on threshold selection and was used to investigate the factors governing PCD performance, including the fundamental advantages and limitations of PCDs in comparison to energy-integrating detectors (EIDs) in the linear regime for which pulse pileup can be ignored. Results: The detector exhibited highly linear mean signal response across the system operating range and agreed well with theoretical prediction, as did the system MTF and NPS. The DQE analyzed as a function of kilovolt (peak), exposure, detector threshold, and readout mode revealed important considerations for system optimization. The model also demonstrated the important implications of false counts from both additive electronic noise and charge sharing and highlighted the system design and operational parameters that most affect detector performance in the presence of such factors: for example, increasing the detector threshold from 0 to 100 (arbitrary units of pulse height threshold roughly equivalent to 0.5 and 6 keV energy threshold, respectively), increased the f{sub 50} (spatial-frequency at which the MTF falls to a value of 0.50) by ∼30% with corresponding improvement in DQE. The range in exposure and additive noise for which PCDs yield intrinsically higher DQE was quantified, showing performance advantages under conditions of very low-dose, high additive noise, and high fidelity rejection of coincident photons. Conclusions: The model for PCD signal and noise performance agreed with measurements of detector signal, MTF, and NPS and provided a useful basis for understanding complex dependencies in PCD imaging performance and the potential advantages (and disadvantages) in comparison to EIDs as well as an important guide to task-based optimization in developing new PCD imaging systems.

60 APPLIED LIFE SCIENCES↗