Search NASA⌕ Search

SEARCH · Search NASA

Results for “range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

WE-G-204-02: Utility of a Channelized Hotelling Model Observer Over a Large Range of Angiographic Exposure Levels

Purpose: Mathematical model observers provide a figure of merit that simultaneously considers a test object and the contrast, noise, and spatial resolution properties of an imaging system. The purpose of this work was to investigate the utility of a channelized Hotelling model observer (CHO) to assess system performance over a large range of angiographic exposure conditions. Methods: A 4 mm diameter disk shaped, iodine contrast test object was placed on a 20 cm thick Lucite phantom and 1204 image frames were acquired using fixed x-ray beam quality and for several detector target dose (DTD) values in the range 6 to 240 nGy. The CHO was implemented in the spatial domain utilizing 96 Gabor functions as channels. Detectability index (DI) estimates were calculated using the “resubstitution” and “holdout” methods to train the CHO. Also, DI values calculated using discrete subsets of the data were used to estimate a minimally biased DI as might be expected from an infinitely large dataset. The relationship between DI, independently measured CNR, and changes in results expected assuming a quantum limited detector were assessed over the DTD range. Results: CNR measurements demonstrated that the angiography system is not quantum limited due to relatively increasing contamination from electronic noise that reduces CNR for low DTD. Direct comparison of DI versus CNR indicates that the CHO relatively overestimates DI for low DTD and/or underestimates DI values for high DTD. The relative magnitude of the apparent bias error in the DI values was ∼20% over the 40x DTD range investigated. Conclusion: For the angiography system investigated, the CHO can provide a minimally biased figure of merit if implemented over a restricted exposure range. However, bias leads to overestimates of DI for low exposures. This work emphasizes the need to verify CHO model performance during real-world application.

60 APPLIED LIFE SCIENCES↗

Luminescence imaging of water during proton-beam irradiation for range estimation

Purpose: Proton therapy has the ability to selectively deliver a dose to the target tumor, so the dose distribution should be accurately measured by a precise and efficient method. The authors found that luminescence was emitted from water during proton irradiation and conjectured that this phenomenon could be used for estimating the dose distribution. Methods: To achieve more accurate dose distribution, the authors set water phantoms on a table with a spot scanning proton therapy system and measured the luminescence images of these phantoms with a high-sensitivity, cooled charge coupled device camera during proton-beam irradiation. The authors imaged the phantoms of pure water, fluorescein solution, and an acrylic block. Results: The luminescence images of water phantoms taken during proton-beam irradiation showed clear Bragg peaks, and the measured proton ranges from the images were almost the same as those obtained with an ionization chamber. Furthermore, the image of the pure-water phantom showed almost the same distribution as the tap-water phantom, indicating that the luminescence image was not related to impurities in the water. The luminescence image of the fluorescein solution had ∼3 times higher intensity than water, with the same proton range as that of water. The luminescence image of the acrylic phantom had a 14.5% shorter proton range than that of water; the proton range in the acrylic phantom generally matched the calculated value. The luminescence images of the tap-water phantom during proton irradiation could be obtained in less than 2 s. Conclusions: Luminescence imaging during proton-beam irradiation is promising as an effective method for range estimation in proton therapy.

60 APPLIED LIFE SCIENCES↗

SU-D-BRA-04: Computerized Framework for Marker-Less Localization of Anatomical Feature Points in Range Images Based On Differential Geometry Features for Image-Guided Radiation Therapy

Purpose: To propose a computerized framework for localization of anatomical feature points on the patient surface in infrared-ray based range images by using differential geometry (curvature) features. Methods: The general concept was to reconstruct the patient surface by using a mathematical modeling technique for the computation of differential geometry features that characterize the local shapes of the patient surfaces. A region of interest (ROI) was firstly extracted based on a template matching technique applied on amplitude (grayscale) images. The extracted ROI was preprocessed for reducing temporal and spatial noises by using Kalman and bilateral filters, respectively. Next, a smooth patient surface was reconstructed by using a non-uniform rational basis spline (NURBS) model. Finally, differential geometry features, i.e. the shape index and curvedness features were computed for localizing the anatomical feature points. The proposed framework was trained for optimizing shape index and curvedness thresholds and tested on range images of an anthropomorphic head phantom. The range images were acquired by an infrared ray-based time-of-flight (TOF) camera. The localization accuracy was evaluated by measuring the mean of minimum Euclidean distances (MMED) between reference (ground truth) points and the feature points localized by the proposed framework. The evaluation was performed for points localized on convex regions (e.g. apex of nose) and concave regions (e.g. nasofacial sulcus). Results: The proposed framework has localized anatomical feature points on convex and concave anatomical landmarks with MMEDs of 1.91±0.50 mm and 3.70±0.92 mm, respectively. A statistically significant difference was obtained between the feature points on the convex and concave regions (P<0.001). Conclusion: Our study has shown the feasibility of differential geometry features for localization of anatomical feature points on the patient surface in range images. The proposed framework might be useful for tasks involving feature-based image registration in range-image guided radiation therapy.

60 APPLIED LIFE SCIENCES↗

SU-F-T-135: A Retrospective Analysis of the Impact of Range Uncertainty in Brain Patients

Purpose: We retrospectively evaluate the dosimetric impact of a 3.5% range uncertainty on CTV coverage and normal organ toxicity for a cohort of brain patients. Methods: Twenty treatment plans involving 20 brain cancer patients treated with Mevions S250 were reviewed. Forty uncertain plans were made by changing the ranges in original plans by ±3.5% while keeping all devices unchanged. Fidelity to the original plans was evaluated with gamma index. Changes in generalized equivalent uniform dose (gEUD) were reported for the following structures: CTV coverage, brainstem, optic chiasm, and optic nerves. Comparisons were made by plotting the relevant endpoints from the uncertain plans as a function of the same endpoints from the original clinical plan. Results: Gamma-index analysis resulted in a 50% pass rate of the uncertain plans using a 90% passing rate and 3%/3mm criterion. A 9.5% decrease in the slope of gEUD plot for the CTV was observed for the 3.5% downward range shift. However, the change in slope did not result in a gEUD change greater than 1.1% for the CTV. The slopes of the gEUD plots for normal structures increased by 3.1% 3.9% 2.4% and 0.2% for the chiasm, brainstem, left optic nerve and right optic nerve respectively. The maximum deviation from the gEUD of the clinical plan for normal structures was: 64% in the chiasm, 31% for the brainstem, and 19% for both optic nerves. Conclusion: A retrospective review shows moderate radiobiological impact of range uncertainty in passively scattered proton therapy with sporadic catastrophe. The linear regression analysis on the statistical data indicates a systematic deviation of gEUD from treatment planning in the light of range uncertainty.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-JeP1-03: Luminescence Imaging of Water During Proton Beam Irradiation for Range Estimation

Purpose: Since proton therapy has the ability to selectively deliver a dose to a target tumor, the dose distribution should be accurately measured. A precise and efficient method to evaluate the dose distribution is desired. We found that luminescence was emitted from water during proton irradiation and thought this phenomenon could be used for estimating the dose distribution. Methods: For this purpose, we placed water phantoms set on a table with a spot-scanning proton-therapy system, and luminescence images of these phantoms were measured with a high-sensitivity cooled charge coupled device (CCD) camera during proton-beam irradiation. We also conducted the imaging of phantoms of pure-water, fluorescein solution and acrylic block. We made three dimensional images from the projection data. Results: The luminescence images of water phantoms during the proton-beam irradiations showed clear Bragg peaks, and the measured proton ranges from the images were almost the same as those obtained with an ionization chamber. The image of the pure-water phantom also showed almost the same distribution as the tap-water phantom, indicating that the luminescence image was not related to impurities in the water. The luminescence image of fluorescein solution had ∼3 times higher intensity than water, with the same proton range as that of water. The luminescence image of the acrylic phantom had 14.5% shorter proton range than that of water; the proton range in the acrylic phantom was relatively matched with the calculated value. The luminescence images of the tap-water phantom during proton irradiation could be obtained in less than 2 sec. Three dimensional images were successfully obtained which have more quantitative information. Conclusion: Luminescence imaging during proton-beam irradiation has the potential to be a new method for range estimations in proton therapy.

60 APPLIED LIFE SCIENCES↗

Structure Function Studies of Vaccinia Virus Host Range Protein K1 Reveal a Novel Functional Surface for Ankyrin Repeat Proteins

Poxvirus host tropism at the cellular level is regulated by virus-encoded host range proteins acting downstream of virus entry. The functioning mechanisms of most host range proteins are unclear, but many contain multiple ankyrin (ANK) repeats, a motif that is known for ligand interaction through a concave surface. We report here the crystal structure of one of the ANK repeat-containing host range proteins, the vaccinia virus K1 protein. The structure, at a resolution of 2.3 {angstrom}, showed that K1 consists entirely of ANK repeats, including seven complete ones and two incomplete ones, one each at the N and C terminus. Interestingly, Phe82 and Ser83, which were previously shown to be critical for K1's function, are solvent exposed and located on a convex surface, opposite the consensus ANK interaction surface. The importance of this convex surface was further supported by our additional mutagenesis studies. We found that K1's host range function was negatively affected by substitution of either Asn51 or Cys47 and completely abolished by substitution of both residues. Cys47 and Asn51 are also exposed on the convex surface, spatially adjacent to Phe82 and Ser83. Altogether, our data showed that K1 residues on a continuous convex ANK repeat surface are critical for the host range function, suggesting that K1 functions through ligand interaction and does so with a novel ANK interaction surface.

36 MATERIALS SCIENCE↗

Relationship between short- and long-range orders in nonstoichiometric titanium monoxide (TiO{sub y})

The relationship between the short- and long-range orders in various phases of nonstoichiometric titanium monoxide (TiO{sub y}) has been analyzed for the first time. The types of the local environment of lattice sites in the metal and nonmetal (oxygen) sublattices of Ti{sub 5}O{sub 5}, Ti{sub 3}O{sub 2}, Ti{sub 2}O{sub 3}, and Ti{sub 4}O{sub 5} superstructures are described. It is established that, in phases where ordering takes place simultaneously in both sublattices, all parameters of the superstructural short-range order determining the positions of atoms and vacancies in the first three coordination spheres can be uniquely expressed via the long-range order parameters. If the ordering takes place only in one sublattice, then five of the six short-range order parameters vanish. It is shown that, using data on the maximum absolute values of six short-range order parameters and on the fractions of occupied atomic positions in titanium and oxygen sublattices, it is possible to predict the type of ordered phase expected to form in the nonstoichiometric titanium monoxide TiO{sub y}.

36 MATERIALS SCIENCE↗

Long-range dispersion-corrected density functional for noncovalent interactions

Noncovalent interactions are important in determining structures and properties of molecular complexes and biological molecules, and for understanding adsorption processes in chemistry and biological science, and are still challenging to conventional density functional theories. In this work, the recently developed Tao-Mo (TM) meta-GGA (generalized gradient approximation) functional is combined with the D3 scheme of long-range van der Waals (vdW) interaction correction and the parameters of damping function are optimized with the S66[Formula: see text]×[Formula: see text]8 set. The resulting TM-D3 method is applied to the medium-sized molecular set S22 and large size molecular complexes set L7 to calculate intramolecular interaction energies. The TM-D3 method produces the best accuracy for the S22 set with a MAE of 0.2 kcal/mol, improving upon the PBE-D3 (MAE[Formula: see text]=[Formula: see text]0.5 kcal/mol), PBE0-D3 (MAE[Formula: see text]=[Formula: see text]0.5 kcal/mol), TPSS-D3 (MAE[Formula: see text]=[Formula: see text]0.4 kcal/mol), M06L (MAE[Formula: see text]=[Formula: see text]0.8 kcal/mol), and SCAN-D3 (MAE[Formula: see text]=[Formula: see text]0.4 kcal/mol) methods. For the large size set L7, the TM-D3 (MAE[Formula: see text]=[Formula: see text]2.1 kcal/mol) also performs better than the PBE-D3 (MAE[Formula: see text]=[Formula: see text]2.6 kcal/mol), SCAN-D3 (2.5 kcal/mol) and M06L (3.0 kcal/mol), but not accurate than the PBE0-D3 (MAE[Formula: see text]=[Formula: see text]0.8 kcal/mol) and TPSS-D3 (MAE[Formula: see text]=[Formula: see text]1.1 kcal/mol). However, overall, the TM-D3 method performs very well with an error of 2.7% of mean binding of the S22 set and an error of 12.6% of the mean binding of the L7 set for the two typical and important medium and large size molecular complex sets. The success of the dispersion-corrected TM functional benefits from the ability of the plain TM functional to capture the short-range vdW interaction or extend the short-range interaction to the middle range, and the right coupling between the TM and the long-range vdW correction D3 scheme, leading to the improved description of noncovalent interactions.

Physics↗

Offset lock with a 440-GHz range using electro-optic modulation

Offset locking is crucial to many physics experiments. Wide range offset locks are desirable, as they increase the span of usable frequencies in an experiment. Here, we experimentally realize a wide-range offset lock using a beat-note setup combined with electro-optic phase modulation. By using frequency down-conversion of the beat note and locking to sidebands generated by electro-optic modulation, we achieve an offset range of ± 220.1 GHz with offset frequency fluctuations under 0.1 Hz and a phase error variance of 0.017 rad 2 over a 100 kHz bandwidth, greatly widening the range compared to past setups using this method. The relative simplicity of our setup provides a compelling method for locking at offsets in the hundreds of GHz range.

Zhou, Ocean (ORCID:0000000279192636)↗

Comparing extracting and recirculating residential kitchen range hoods for the use in high energy efficient housing

Residential cooking can be a significant indoor source of odour, pollutants and particulate matter. Conventionally, range hoods expel the air into the ambient. A number of studies have investigated their contaminant capture performance. However, for highly energy efficient houses the installation of extracting range hoods can pose certain challenges, e.g. high ventilation losses, additional thermal bridges and potential air leakage sites. Therefore, the use of recirculation range hoods has become standard for highly energy efficient housing with mechanical ventilation with heat recovery in Central Europe. Open questions remain regarding their capture and filtration efficiency as a function of filter age, especially for particles and odours. But also, the actual energy savings potential when using recirculating instead of extracting devices in a highly energy efficient housing had not been documented yet. This paper addresses these questions with a literature review and an energetic comparison. The review identified a good number of studies which have investigated the capture performance of extracting range hoods with a focus on pollutants resulting from gas combustion and/or the cooking generated particles. These studies show that capture efficiency, in particular for front burner use, can vary drastically for different designs and that particle capture does not necessarily match capture efficiency for gaseous contaminants. No scientific study investigating the performance of recirculating range hoods was found. Tests for consumer magazines as well as surveys indicate notably lower performance compared to extracting hoods. In summary one can say that performance tests are urgently needed to quantify the capture and filter efficiency for particles and (odorous) organic compounds as a function of filter age.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Floodplain Assessment for the Proposed Outdoor Fire Range Upgrades at TA-72 in Lower Sandia Canyon, Los Alamos National Laboratory

Los Alamos National Laboratory (LANL) is preparing to implement actions in Sandia Canyon at Technical Area (TA) 72. Los Alamos National Security (LANS) biologists conducted a floodplain determination and this project is partially located within a 100-year floodplain. The proposed project is to upgrade the existing outdoor shooting range facilities at TA-72. These upgrades will result in increased safety and efficiencies in the training for Protective Force personnel. In order to remain current on training requirements, the firing ranges at TA-72 will be upgraded which will result in increased safety and efficiencies in the training for Protective Force personnel (Figure 1). These upgrades will allow for an increase in class size and more people to be qualified at the ranges. Some of these upgrades will be built within the 100-year floodplain. The upgrades include: concrete pads for turning target systems and shooting positions, new lighting to illuminate the firing range for night fire, a new speaker system for range operations, canopies at two locations, an impact berm at the far end of the 300-yard mark, and a block wall for road protection.

Basic Biological Sciences(59)↗

Representing Range Compensators with Computational Geometry in TOPAS

In a proton therapy beamline, the range compensator modulates the beam energy, which subsequently controls the depth at which protons deposit energy. In this paper, we introduce two computational representations of range compensator. One of our compensator representations, which we refer to as a subtraction solid-based range compensator, precisely represents the compensator. Our other representation, the 3D hexagon-based range compensator, closely approximates the compensator geometry. We have implemented both of these compensator models in a proton therapy Monte Carlo simulation called TOPAS (Tool for Particle Simulation). In the future, we will present a detailed study of the accuracy and runtime performance trade-offs between our two range compensator representations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radar range measurements in the atmosphere

The earth's atmosphere affects the velocity of propagation of microwave signals. This imparts a range error to radar range measurements that assume the typical simplistic model for propagation velocity. This range error is a function of atmospheric constituents, such as water vapor, as well as the geometry of the radar data collection, notably altitude and range. Models are presented for calculating atmospheric effects on radar range measurements, and compared against more elaborate atmospheric models.

Doerry, Armin Walter↗

Cummins Electric Truck with Range-Extending Engine (ETREE) Project (Final Technical Report)

The Cummins Electric Truck with Range Extending Engine (ETREE) program designed, developed, and demonstrated a range extending electric vehicle that employs an electrified propulsion system installed in a class 6 commercial vehicle (Peterbilt 220). This project was relevant to industry and the greater public because at the time of the project there were two keys to widespread electrified commercial vehicle adoption yet to be realize: 1) For pure electrified vehicle adoption, battery improvements are needed: Cost must decrease, and energy density must increase. 2) Electric vehicles must overcome fleet operator risks such as: operations in cold climates, hilly terrain, or where majority of conventional trucks are replaced with electrified vehicles. In the near to medium term these adoption hurdles were address by the objectives of this project. A plug-in hybrid vehicle that could be operated in all electric mode for most of its workday optimizing the use of grid energy with the ability to supplement energy demand with the onboard range extending engine. This project’s architecture provided ability to match a conventional class 6 commercial vehicle range and performance characteristics prior to the ubiquitous adoption of battery electric vehicle charging infrastructure as well. Additionally, the vehicles produced as part of this project can be considered a prototype for a commercially viable heavily electrified commercial vehicle because most of the physical hardware used for the project is commercially available in the market today. The ETREE program met its main objectives and demonstrated 65% fuel consumption reduction as compared to a conventional class 6 vehicle while meeting performance and range expectations. This was achieved by drawing upon the strengths of the assembled team: Cummins, PACCAR, the Ohio State University, Argonne National Laboratory and the National Renewable Energy Laboratory.

20 FOSSIL-FUELED POWER PLANTS↗

An extrapolation method for strain ranges and hold times in developing the EPP+SMT creep-fatigue design curves for Alloy 617

Experimental and numerical studies in developing the integrated Elastic–Perfectly Plastic (EPP) plus Simplified Model Test (SMT) design methodology, referred to as the EPP+SMT method, continued in FY2022. This report focuses on the methods for extrapolating the EPP+SMT creep-fatigue (CF) design curves at long hold times and low strain ranges. In this study, the available CF failure data on Alloy 617 at 950°C were analyzed to determine a set of CF failure criteria. At very low strain ranges and long hold times, CF failure data are not accessible by experiments because of the extraordinarily long test durations and the inability of the test machines to accurately control these small strain ranges. A CF experimental approach with the concept of block-strain range CF testing protocol was developed. Tests using this protocol were conducted to generate the needed information for calibrating material parameters of the numerical material models. The Time Fraction based method and Dissipated Energy method were used to extrapolate the CF life curves to low strain ranges and long hold times. Based on the new experimental approach and CF life prediction methods, the CF life curves with various hold times were developed for Alloy 617 at 950°C. In addition, an experiment was designed and is being performed to verify the predicted CF curves at 950°C. The extrapolation procedure will be applied at lower temperatures to complete the development of the EPP+SMT CF design curves for Alloy 617 in F2023.

36 MATERIALS SCIENCE↗

Extrapolation of the Rainflow-Counted Load Ranges for Fatigue Assessment of the Wind Turbine's Blades

Wind turbine design standards recommend the use of statistical modeling coupled with extrapolation of the short-term load data to long-term periods for fatigue reliability assessment. However, statistical error and computational expense can limit the accuracy of such approaches. In the case of wind turbine blades, the errors are more significant because of the high material fatigue exponent that makes the damage estimations more sensitive to variations. In addition, due to different excitation sources, the flapwise load range histogram is not unimodal, and thus its statistical modeling is complex. In the present work, we provide three methods for statistical modeling of the flapwise bending moment ranges including a novel approach based on frequency-based separation of the modes. The first two methods are simplified approaches for modeling the most crucial load ranges using unimodal distributions and the third method involves multimodal distribution fitting. The research is based on 3600 10-minute aeroelastic simulations of DTU 10MW case study wind turbine from which a benchmark damage equivalent load (DEL) is calculated. The DEL calculated by each of the three proposed methods is compared to this reference. The results show that the conventional approach based on using 6 seeds as well as using mixture models fitted on the limited data lead to under-conservative results with errors up to 23%. On the other hand, the simplified unimodal approaches provided in this work can provide conservative estimations of the fatigue damage with mean values 5% and 12% higher than the benchmark. However, the variability of the DEL estimates is higher when using unimodal extrapolation of the load ranges, and the data can be conservative by 17.5%. The proposed unimodal fits suggested for modeling and extrapolation of the blade's load ranges provide less errors relatively and most importantly conservative DEL estimations while maintaining computational efficiency.

blade fatigue↗

Representation of the QM Subsystem for Long-Range Electrostatic Interaction in Non-Periodic Ab Initio QM/MM Calculations

In QM/MM calculations, it is essential to handle electrostatic interactions between the QM and MM subsystems accurately and efficiently. To achieve maximal efficiency, it is convenient to adopt a hybrid scheme, where the QM electron density is used explicitly in the evaluation of short-range QM/MM electrostatic interactions, while a multipolar representation for the QM electron density is employed to account for the long-range QM/MM electrostatic interactions. In order to avoid energy discontinuity at the cutoffs, which separate the short- and long-range QM/MM electrostatic interactions, a switching function should be utilized to ensure a smooth potential energy surface. In this study, we benchmarked the accuracy of such hybrid embedding schemes for QM/MM electrostatic interactions using different multipolar representations, switching functions and cutoff distances. For test systems (neutral and anionic oxyluciferin in MM (aqueous and enzyme) environments), the best accuracy was acquired with a combination of QM electrostatic potential (ESP) charges and dipoles and two switching functions (long-range electrostatic corrections (LREC) and Switch) in the treatment of long-range QM/MM electrostatics. It allowed us to apply a 10Å distance cutoff and still obtain QM/MM electrostatics/polarization energies within 0.1 kcal/mol and time-dependent density functional theory (TDDFT)/MM vertical excitation energies within 10−3 eV from theoretical reference values.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effect Of Platooning on Fuel Consumption of Class 8 Vehicles Over a Range of Speeds, Following Distances, and Mass

This research project evaluates fuel consumption results of two Class 8 tractor-trailer combinations platooned together compared to their standalone fuel consumption. A series of ten modified SAE Type II J1321 fuel consumption track tests were performed to document fuel consumption of two platooned vehicles and a control vehicle at varying steady-state speeds, following distances, and gross vehicle weights (GVWs). The steady-state speeds ranged from 55 mph to 70 mph, the following distances ranged from a 20-ft following distance to a 75-ft following distance, and the GVWs were 65K lbs and 80K lbs. All tractors involved had U.S. Environmental Protection Agency (EPA) SmartWay-compliant aerodynamics packages installed, and the trailers were equipped with side skirts. Effects of vehicle speed, following distance, and GVW on fuel consumption were observed and analyzed. The platooning demonstration system used in this study consisted of radar systems, Dedicated Short-Range Communication (DSRC) vehicle-to-vehicle (V2V) communications, vehicle braking and torque control interface, cameras and driver displays. The lead tractor consistently demonstrated an improvement in average fuel consumption reduction as following distance decreased, with results showing 2.7% to 5.3% fuel savings at a GVW of 65k. The trailing vehicle achieved fuel consumption savings ranging from 2.8% to 9.7%; tests during which the engine cooling fan did not operate achieved savings of 8.4% to 9.7%. 'Team' fuel savings, considering the platooned vehicles as one, ranged from 3.7% to 6.4%, with the best combined result being for 55 mph, 30-ft following distance, and 65k GVW.

33 ADVANCED PROPULSION SYSTEMS↗