Search NASA⌕ Search

SEARCH · Search NASA

Results for “read performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

The adult literacy evaluator: An intelligent computer-aided training system for diagnosing adult illiterates

An important part of NASA's mission involves the secondary application of its technologies in the public and private sectors. One current application being developed is The Adult Literacy Evaluator, a simulation-based diagnostic tool designed to assess the operant literacy abilities of adults having difficulties in learning to read and write. Using ICAT system technology in addition to speech recognition, closed-captioned television (CCTV), live video and other state-of-the art graphics and storage capabilities, this project attempts to overcome the negative effects of adult literacy assessment by allowing the client to interact with an intelligent computer system which simulates real-life literacy activities and materials and which measures literacy performance in the actual context of its use. The specific objectives of the project are as follows: (1) To develop a simulation-based diagnostic tool to assess adults' prior knowledge about reading and writing processes in actual contexts of application; (2) to provide a profile of readers' strengths and weaknesses; and (3) to suggest instructional strategies and materials which can be used as a beginning point for remediation. In the first and developmental phase of the project, descriptions of literacy events and environments are being written and functional literacy documents analyzed for their components. Examples of literacy events and situations being considered included interactions with environmental print (e.g., billboards, street signs, commercial marquees, storefront logos, etc.), functional literacy materials (e.g., newspapers, magazines, telephone books, bills, receipts, etc.) and employment related communication (i.e., job descriptions, application forms, technical manuals, memorandums, newsletters, etc.). Each of these situations and materials is being analyzed for its literacy requirements in terms of written display (i.e., knowledge of printed forms and conventions), meaning demands (i.e., comprehension and word knowledge) and social situation. From these descriptions, scripts are being generated which define the interaction between the student, an on-screen guide and the simulated literacy environment. The proposed outcome of the Evaluator is a diagnostic profile which will present broad classifications of literacy behaviors across the major areas of metacognitive abilities, word recognition, vocabulary knowledge, comprehension and writing. From these classifications, suggestions for materials and strategies for instruction with which to begin corrective action will be made. The focus of the Literacy Evaluator will be essentially to provide an expert diagnosis and an interpretation of that assessment which then can be used by a human tutor to further design and individualize a remedial program as needed through the use of an authoring system.

Yaden, David B., Jr.↗

WE-DE-201-05: Evaluation of a Windowless Extrapolation Chamber Design and Monte Carlo Based Corrections for the Calibration of Ophthalmic Applicators

Purpose: To test the validity of a windowless extrapolation chamber used to measure surface dose rate from planar ophthalmic applicators and to compare different Monte Carlo based codes for deriving correction factors. Methods: Dose rate measurements were performed using a windowless, planar extrapolation chamber with a {sup 90}Sr/{sup 90}Y Tracerlab RA-1 ophthalmic applicator previously calibrated at the National Institute of Standards and Technology (NIST). Capacitance measurements were performed to estimate the initial air gap width between the source face and collecting electrode. Current was measured as a function of air gap, and Bragg-Gray cavity theory was used to calculate the absorbed dose rate to water. To determine correction factors for backscatter, divergence, and attenuation from the Mylar entrance window found in the NIST extrapolation chamber, both EGSnrc Monte Carlo user code and Monte Carlo N-Particle Transport Code (MCNP) were utilized. Simulation results were compared with experimental current readings from the windowless extrapolation chamber as a function of air gap. Additionally, measured dose rate values were compared with the expected result from the NIST source calibration to test the validity of the windowless chamber design. Results: Better agreement was seen between EGSnrc simulated dose results and experimental current readings at very small air gaps (<100 µm) for the windowless extrapolation chamber, while MCNP results demonstrated divergence at these small gap widths. Three separate dose rate measurements were performed with the RA-1 applicator. The average observed difference from the expected result based on the NIST calibration was −1.88% with a statistical standard deviation of 0.39% (k=1). Conclusion: EGSnrc user code will be used during future work to derive correction factors for extrapolation chamber measurements. Additionally, experiment results suggest that an entrance window is not needed in order for an extrapolation chamber to provide accurate dose rate measurements for a planar ophthalmic applicator.

07 ISOTOPE AND RADIATION SOURCES↗

Architecture for the Performance of Nuclear Fuel Depletion Calculations

Computational analysis of the depletion of nuclear fuel is crucial to the accurate modeling of the time-dependent behavior of nuclear reactors. The reactor physics application MAMMOTH is modified to compute radioactive decay and neutron transmutation in order to model physical processes which occur within nuclear reactors as reactor fuel is burned. The ability to read decay and cross-section data files of other codes are also added and the addition of a standardized decay and transmutation XML file format for MAMMOTH, known as ISOXML. Comparisons between MAMMOTH and the Oak Ridge Isotope Generation (ORIGEN) code are performed to demonstrate the improved precision possible with MAMMOTH. In addition, several tests are run to demonstrate the ability of MAMMOTH to model decay and transmutation processes involving hundreds of isotopes. Future work will focus on solving depletion problems with multiple neutron energy groups and the implementation of predictor-corrector methods, several of which are described in this work.

07 ISOTOPE AND RADIATION SOURCES↗

Statistical performance of the intensified charged coupled device

The first analysis of the statistical performance of the intensified charge coupled device (CCD) is presented. The Poisson statistics of the arriving photons, the exponential pulse height distribution of the microchannel plate in the image intensifier, and the effects of discrete digitization of the charge in reading the CCD are included. A range of intensifier gains from the high levels that permit pulse counting to the low levels that can be used with the accumulation of charge on the CCD is considered. As a tool for this analysis, an analytical model of the performance of the detector system that is generally useful for predicting many aspects of system performance under a wide range of conditions is developed. The statistical penalty for operating the intensified CCD in the charge accumulation mode is not severe, and in some applications it may be desirable to accept this penalty to gain the advantages of increased dynamic range through charge accumulation. This investigation has revealed no pathological aspects of the operation of the detector system.

Sandel, B. R.↗

X-ray fluorescence analysis for prediction of Space Shuttle solid rocket motor performance

Analysis of uncured solid propellant by X-ray fluorescence has been conducted on mixes prepared for four development motors produced for the Space Shuttle SRM Project. X-ray readings for chlorine (ammonium perchlorate) and iron (ferric oxide) were recorded for each mix during processing of the propellant. These values were used to predict burning rates for uncured acceptance, uncured acoustic emission and cured acoustic emission strands. Predicted burning rates all fell within control limits and when compared to actual burning rates, most were within experimental error. The X-ray analysis required one-third the time of current methods and met casting schedules.

Pulsipher, H. G.↗

The Development of a Data Archive and Analysis Tools for WIRE

Although a number of missions to perform asteroseismology from orbit are planned, such as the French COROT (currently scheduled for launch in 2004), the Canadian MOST (2002), and the Danish MONS (2003), none has yet been successfully flown. However, from May 1999 through September 2000, the PI of this proposal initiated a program using the star camera on board the WIRE spacecraft to perform high-precision photometry of solar-like and giant stars. This program relied on the on-board star camera, which consists of a 50mm f/1.75 telescope feeding a 512(sup 2) SITe CCD, which can be read out at rates as high as 10 Hz. The high cadence of observations available with this star camera is made possible by software that locates the 5 brightest stars in the field and reads only an 8x8 pixel box around one selected image. An additional mode of operation, available since November 1999, makes count rate data available on all five stellar images, with a consequent loss of read rate (to 2 Hz for 5 stars). Stellar images are defocused (to allow for more accurate image centroiding), but the entire stellar image lies within the 64-pixel box. we note that in many ways, this instrument is similar to the French instrument EVRIS, which was intended to perform asteroseismology with a 90 mm telescope, but which unfortunately flew as part of the failed Russian MARS 96 spacecraft.

Buzasi, Derek L.↗

Image quality and diagnostic accuracy of complex-averaged high b value images in diffusion-weighted MRI of prostate cancer

Purpose: To evaluate the impact of complex-averaging on image quality (IQ) and diagnostic accuracy of acquired and calculated high b value (aHBV, cHBV) images in diffusion-weighted prostate MRI. Materials and methods: This retrospective study included 84 patients who underwent multiparametric prostate MRI at 3 Tesla without endorectal coil. DWIs were acquired at three different b values which included two lower b values (b = 50,900 s/mm{sup 2}) and one higher b value (aHBV at 2000 s/mm{sup 2}). The acquired data were postprocessed to generate two different types of trace-weighted images—using conventional magnitude-averaging and complex-averaging. Using lower b values (b = 50,900 s/mm{sup 2}) from both conventional and complex-averaged image sets, cHBV images (b = 2000 s/mm{sup 2}) and ADC maps were derived. All image sets were reviewed by two radiologists in different reading sessions to assess image quality and PIRADS. The diagnostic accuracy of different image sets for the detection of prostate lesions was performed by correlating PIRADS and Gleason scores. Results: Complex-averaging did not impact ADC values of the prostate lesions compared to magnitude-averaging (P = 0.08). Complex-averaging improved image quality of acquired high b value and calculated high b value images (P < 0.0001). Complex-averaging also improved the level of confidence (LOC) of the acquired high b value for both readers (P < 0.0001, P < 0.05), but only for reader A in calculated high b value (P < 0.0001). The image quality of calculated high b value images was not significantly different than acquired high b value images. The dataset combining complex-averaging and calculated high b value provided the highest diagnostic accuracy (but not statistically significant) for detection of the significant prostate lesion compared to the magnitude-averaged acquired high b value (79.55% vs. 72.73%; P = 0.317). The mean acquisition time for b = 2000 s/mm{sup 2} sequence (aHBV) was 6 min 30 s (± 1 min 16 s) out of a total of 28 min 31 s (± 4 min 26 s) for the entire mp-MRI protocol (approximately 25% of total scan time). Conclusion: Complex-averaging provides better image quality and level of confidence without significant impact on ADC values and diagnostic accuracy for detection of the significant prostate lesions . The calculated high b value images are also comparable to (and can substitute) the acquired high b value images which can help in reducing the imaging time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High power cascaded mid-infrared InAs/GaSb light emitting diodes on mismatched GaAs

InAs/GaSb mid-wave, cascaded superlattice light emitting diodes are found to give higher radiance when epitaxially grown on mismatched GaAs substrates compared to lattice-matched GaSb substrates. Peak radiances of 0.69 W/cm{sup 2}-sr and 1.06 W/cm{sup 2}-sr for the 100 × 100 μm{sup 2} GaSb and GaAs-based devices, respectively, were measured at 77 K. Measurement of the recombination coefficients shows the shorter Shockley-Read-Hall recombination lifetime as misfit dislocations for growth on GaAs degrade the quantum efficiency only at low current injection. The improved performance on GaAs was found to be due to the higher transparency and improved thermal properties of the GaAs substrate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Joint Estimation of Behind-the-Meter Solar Generation in a Community

Distribution grid planning, control, and optimization require accurate estimation of solar photovoltaic (PV) generation and electric load in the system. Most of the small residential solar PV systems are installed behind-the-meter making only the net load readings available to the utilities. This paper presents an unsupervised framework for joint disaggregation of the net load readings of a group of customers into the solar PV generation and electric load. Our algorithm synergistically combines a physical PV system performance model for individual solar PV generation estimation with a statistical model for joint load estimation. The electric loads for a group of customers are estimated jointly by a mixed hidden Markov model (MHMM) which enables modeling the general load consumption behavior present in all customers while acknowledging the individual differences. At the same time, the model can capture the change in load patterns over a time period by the hidden Markov states. The proposed algorithm is also capable of estimating the key technical parameters of the solar PV systems. Our proposed method is evaluated using the net load, electric load, and solar PV generation data gathered from residential customers located in Austin, Texas. Testing results show that our proposed method reduces the mean squared error of state-of-the-art net-load disaggregation algorithms by 67%.

behind-the-meter solar generation↗

Omics Metadata Management Software v. 1 (OMMS)

Our application, the Omics Metadata Management Software (OMMS), answers both needs, empowering experimentalists to generate intuitive, consistent metadata, and to perform bioinformatics analyses and information management tasks via a simple and intuitive web-based interface. Several use cases with short-read sequence datasets are provided to showcase the full functionality of the OMMS, from metadata curation tasks, to bioinformatics analyses and results management and downloading. The OMMS can be implemented as a stand alone-package for individual laboratories, or can be configured for web-based deployment supporting geographically dispersed research teams. Our software was developed with open-source bundles, is flexible, extensible and easily installed and run by operators with general system administration and scripting language literacy.

Powell, Amy↗

Girder Profile Reproducing Residuals Report

Girder profile is represented by 6 or 8 girder fiducials, depending on the length of the girder. The profile is recorded precisely in environmentally controlled room (ER) where vibrating wire measurement is taken place. The girder profile is expected to be reproduced in tunnel by following a strictly-designed procedure. Girder profile is adjusted by referring to the dynamic reading of laser tracker and is recorded by multiple shots to common targets and girder fiducials. A final 6 tracker setup is performed to confirm the girder profile reported by 2 trackers and report the magnet relative height location by including magnet top fiducial observation. In order to further isolate the impact of instrument and monument geometry, the girder fiducials that are symmetrical relative to beam centerline will be averaged to compute girder profile error. The girder profile reproducing residuals will be summarized for the girders have been profiled so far.

36 MATERIALS SCIENCE↗

Girder Profile Reproducing Residuals Report

Girder profile is represented by 6 or 8 girder fiducials, depending on the length of the girder. The profile is recorded precisely in environmentally controlled room (ER) where vibrating wire measurement is taken place. The girder profile is expected to be reproduced in tunnel by following a strictly-designed procedure. Girder profile is adjusted by referring to the dynamic reading of laser tracker and is recorded by multiple shots to common targets and girder fiducials. A final 6 tracker setup is performed to confirm the girder profile reported by 2 trackers and report the magnet relative height location by including magnet top fiducial observation. In order to further isolate the impact of instrument and monument geometry, the girder fiducials that are symmetrical relative to beam centerline will be averaged to compute girder profile error. The girder profile reproducing residuals will be summarized for the girders have been profiled so far.

36 MATERIALS SCIENCE↗

DAOS Benchmarks and Findings

We benchmark DAOS on a 127-node, 4,064-target pool using fio, IOR, IO500, and mdtest, comparing the DFS API against DFuse+POSIX. Single-client fio sweeps show larger block sizes and writes yield higher bandwidth, with similar random/sequential performance. Multi-node IOR (1–32 nodes, 6–48 tasks/node) shows bandwidth saturating around 32 tasks/node, with large transfer sizes hurting read throughput at high concurrency and write latency growing faster than read latency. An 8-node IO500 run shows DFS achieving ~5x higher bandwidth and ~190x higher IOPS than POSIX. We also detail operational issues: SCM target-filling under mdtest, intermittent NA_HOSTUNREACH errors, fio CPU-affinity failures, and a pool error storm resolved by recreation.

George, Rebecca [Thomas Jefferson National Acceler↗

Rotorcraft Digital Advanced Avionics System (rodaas)

A simulator is being built to determine the practicality of using an advanced avionics system in a helicopter. Features include an autopilot; a navigation and flight planning component; an advisory system built into the computer; conventional gages and displays; a clock function; a fuel totalizer; a weight and balance computator; a performance evaluator; and emergency and normal checklists. The translation of a computer program written in PASCAL into a form that can be read by the graphics package for the simulator and basic electronic work in simulator construction are discussed.

Taira, B.↗

Fast Pixel Buffer For Processing With Lookup Tables

Proposed scheme for buffering data on intensities of picture elements (pixels) of image increases rate or processing beyond that attainable when data read, one pixel at time, from main image memory. Scheme applied in design of specialized image-processing circuitry. Intended to optimize performance of processor in which electronic equivalent of address-lookup table used to address those pixels in main image memory required for processing.

Fisher, Timothy E.↗

Performance of Thermal Mass Flow Meters in a Variable Gravitational Environment

The performance of five thermal mass flow meters, MKS Instruments 179A and 258C, Unit Instruments UFM-8100, Sierra Instruments 830L, and Hastings Instruments HFM-200, were tested on the KC-135 Reduced Gravity Aircraft in orthogonal, coparallel, and counterparallel orientations relative to gravity. Data was taken throughout the parabolic trajectory where the g-level varied from 0.01 to 1.8 times normal gravity. Each meter was calibrated in normal gravity in the orthogonal position prior to flight followed by ground testing at seven different flow conditions to establish a baseline operation. During the tests, the actual flow rate was measured independently using choked-flow orifices. Gravitational acceleration and attitude had a unique effect on the performance of each meter. All meters operated within acceptable limits at all gravity levels in the calibrated orthogonal position. However, when operated in other orientations, the deviations from the reference flow became substantial for several of the flow meters. Data analysis indicated that the greatest source of error was the effect of orientation, followed by the gravity level. This work emphasized that when operating thermal flow meters in a variable gravity environment, it is critical to orient the meter in the same direction relative to gravity in which it was calibrated. Unfortunately, there was no test in normal gravity that could predict the performance of a meter in reduced gravity. When operating in reduced gravity, all meters indicated within 5 percent of the full scale reading at all flow conditions and orientations.

Brooker, John E.↗

Laser Sounder for Measuring Atmospheric CO2 Concentrations: Progress Toward Ascends

The next generation of space-based, active remote sensing instruments for measurement of tropospheric CO2 promises a capability to quantify global carbon sources and sinks at regional scales. Active (laser) methods will extend CO2 measurement coverage in time, space, and perhaps precision such that the underlying mechanisms for carbon exchange at the surface can be understood with .sufficient detail to confidently project the future of carbon-climate interaction and the influence of remediative policy actions. The recent Decadal Survey for Earth Science by the US National Research Council has recommended such a mission called the Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) for launch in 2013-2016. We have been developing a laser technique for measurement of tropospheric CO2 for a number of years. Our immediate goal is to develop and demonstrate the method and instrument technology that will permit measurements of the CO2 column abundance over a horizontal path and from aircraft at the few-ppmv level. Our longer-term goal is to demonstrate the required capabilities of the technique, develop a space mission approach, and design the instrument for an ASCENDS-type mission. Our approach is to use a dual channel laser absorption spectrometer (i.e., differential absorption in altimeter mode), which continuously measures from a near-polar circular orbit. We use several co-aligned tunable fiber laser transmitters allowing simultaneous measurement of the absorption from a CO2 line in the 1570 nm band, O2 extinction in the oxygen A-band (near 765 nm), and aerosol backscatter in the same measurement path. We measure the energy of the laser echoes at nadir reflected from land and water surfaces, day and night. The lasers have spectral widths much narrower than the gas absorption lines and are turned on and off the selected CO2 and O2 lines at kHz rates. The gas extinction and column densities for the CO2 and O2 gases are estimated from the ratio of the on and off-line singnals via the DIAL technique. We used pulsed laser signals, photon counting detectors, and time gating to isolate the laser returns from the surface, and to reject photons scattered from thin clouds and aerosols. High signal-to-noise ratios are required and the CO2 estimates can be sensitive to small drifts or other errors in the instrument, so the absorption estimates need to be quite stable for hours. We have constructed a breadboard version of the CO2 sensor that uses a low power fiber laser and a 20 cm diameter telescope. We have used it to make measurements of CO2 absorption in the laboratory and over 200-m to 2-km long open horizontal paths. These have been done in several sessions extending over multiple days, which allows us to assess the measurement stability and to compare absorption variations to readings from an external in situ CO2 sensor. We have also calculated characteristics of the technique for space including its expected measurement performance for different modulation types, and have performed an initial space mission accommodation study. We sill describe these results in the presentation.

Abshire, J. B.↗

Omics Metadata Management Software v. 1 (OMMS)

Our application, the Omics Metadata Management Software (OMMS), answers both needs, empowering experimentalists to generate intuitive, consistent metadata, and to perform bioinformatics analyses and information management tasks via a simple and intuitive web-based interface. Several use cases with short-read sequence datasets are provided to showcase the full functionality of the OMMS, from metadata curation tasks, to bioinformatics analyses and results management and downloading. The OMMS can be implemented as a stand alone-package for individual laboratories, or can be configured for web-based deployment supporting geographically dispersed research teams. Our software was developed with open-source bundles, is flexible, extensible and easily installed and run by operators with general system administration and scripting language literacy.

Source record↗