Search NASA⌕ Search

SEARCH · Search NASA

Results for “reference device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

623 records · Page 35

Vacuum Sealable Container (VSC) and Astronaut Lunar Drill (ALD) for Artemis

Introduction: NASA’s Artemis Program is under development to send first woman and next man to the Moon. Artemis will utilize a suite of new technology for Lunar exploration, including new space vehicles, new space suits, and new Astronaut Tools. Honeybee Robotics has been working with NASA JSC to develop a new Vacuum Sealable Container (VSC) and new Astronaut Lunar Drill (ALD) for the upcoming Artemis missions. Vacuum Sealable Container: Sample return continues to be the “Holy Grail” of space exploration, allowing for the analysis of materials using Earth-based laboratories instead of needing to miniaturize and ruggedize instrumentation for space. The Apollo missions to the Moon had several kinds of Sealable Containers which brought back Lunar samples for analysis [1]. These samples are still being analyzed, fifty years later. The VSC requirements are different from that for Apollo containers and as such, new development was required. One major difference between Artemis samples and those from Apollo is the desire to bring back volatiles which may be part of lunar regolith. The VSC is designed to withstand a high-pressure differential caused by sublimating volatiles. Because of the new, stricter sealing requirements, additional features have been added to the VSC. For example, the seal on the container is required to be more robust, thus required more force to actuate, and the seal must be locked in place with a secondary mechanism. Astronaut Lunar Drill: The ALD is designed to be a multi-functional platform for Lunar sample acquisition. The drill builds on lessons learned from the Apollo Lunar Surface Drill (ALSD), as well as Honeybee’s long history of mechanized sample acquisition devices for space [2]. The main functionality of the ALD is Deep Core Regolith Drilling. Additional functionality includes Surface Rock Coring (SRC), and GeoTech Tools (GTT). The ALD is a rotary-percussive drill designed with deep drilling in mind. The ALD is currently designed to have decoupled rotary and percussion subsystems to allow for maximum battery life and reduced fatigue on the crewmember. Honeybee drill technology will automatically engage the percussion when needed to drill at maximum efficiency. The mechanized drill stand helps improve drilling efficiency; the system utilizes advanced drilling algorithms which only require the crewmember to hold a single switch. Additionally, the stand aids in extraction of deep cores, something which was a problem on Apollo. The SRC functionality of the ALD utilizes Honeybee’s Eccentric Tube Core Breakoff technology to collect and retain rock core samples. This technology has also been infused into the Perseverance rover mission. The ALD is removable from the stand to allow crewmembers to collect samples from large boulders. Bringing back rock cores samples instead of full rocks allows for a wider variety of samples to be returned to Earth for study and puts them in a uniform form-factor for effective sealing and analysis. SRC bits will utilize the power of the drill’s percussion system to drill hard Lunar rocks and expedite sample acquisition. The mechanized stand on the ALD allows for additional attachments for taking geotechnical measurements with a Static Cone Penetrometer (SCP) and a Shear Vane (SV). With the stand, the ALD can take SCP measurements with the touch of a button, storing data for return to Earth. SV measurements utilize the ALD’s Rotary motor to spin the vanes in a controlled manner, getting clean data untampered by human error. References: [1] Bar Cohen and Zacny (2009), Drilling in Extreme Environments - Penetration and Sampling on Earth and Other Planets, Wiley. [2] Bar-Cohen and Zacny, Advances in Terrestrial and Extraterrestrial Drilling, CRC Press. [3] Myrick (2003), Core Break-off Mechanism. US Patent No. 6,550,549 Acknowledgements: This work has been supported by NASA via SBIR Phase 3.

Artemis↗

Holographic Optical Data Storage

Although the basic idea may be traced back to the earlier X-ray diffraction studies of Sir W. L. Bragg, the holographic method as we know it was invented by D. Gabor in 1948 as a two-step lensless imaging technique to enhance the resolution of electron microscopy, for which he received the 1971 Nobel Prize in physics. The distinctive feature of holography is the recording of the object phase variations that carry the depth information, which is lost in conventional photography where only the intensity (= squared amplitude) distribution of an object is captured. Since all photosensitive media necessarily respond to the intensity incident upon them, an ingenious way had to be found to convert object phase into intensity variations, and Gabor achieved this by introducing a coherent reference wave along with the object wave during exposure. Gabor's in-line recording scheme, however, required the object in question to be largely transmissive, and could provide only marginal image quality due to unwanted terms simultaneously reconstructed along with the desired wavefront. Further handicapped by the lack of a strong coherent light source, optical holography thus seemed fated to remain just another scientific curiosity, until the field was revolutionized in the early 1960s by some major breakthroughs: the proposition and demonstration of the laser principle, the introduction of off-axis holography, and the invention of volume holography. Consequently, the remainder of that decade saw an exponential growth in research on theory, practice, and applications of holography. Today, holography not only boasts a wide variety of scientific and technical applications (e.g., holographic interferometry for strain, vibration, and flow analysis, microscopy and high-resolution imagery, imaging through distorting media, optical interconnects, holographic optical elements, optical neural networks, three-dimensional displays, data storage, etc.), but has become a prominent am advertising, and security medium as well. The evolution of holographic optical memories has followed a path not altogether different from holography itself, with several cycles of alternating interest over the past four decades. P. J. van Heerden is widely credited for being the first to elucidate the principles behind holographic data storage in a 1963 paper, predicting bit storage densities on the order of 1/lambda(sup 3) with source wavelength lambda - a fantastic capacity of nearly 1 TB/cu cm for visible light! The science and engineering of such a storage paradigm was heavily pursued thereafter, resulting in many novel hologram multiplexing techniques for dense data storage, as well as important advances in holographic recording materials. Ultimately, however, the lack of such enabling technologies as compact laser sources and high performance optical data I/O devices dampened the hopes for the development of a commercial product. After a period of relative dormancy, successful applications of holography in other arenas sparked a renewed interest in holographic data storage in the late 1980s and the early 1990s. Currently, with most of the critical optoelectronic device technologies in place and the quest for an ideal holographic recording medium intensified, holography is once again considered as one of several future data storage paradigms that may answer our constantly growing need for higher-capacity and faster-access memories.

Timucin, Dogan A.↗

X-Ray Computed Tomography of Apollo Drive Tube 73001 as Part of the Apollo Next Generation Sample Analysis Program

Introduction: Starting in 2019, the Apollo Next Generation Sample Analysis (ANGSA) Program has enabled consortium studies of specially curated Apollo samples that were previously unstudied (or under studied). This program was intended as a participating scientist program for these Apollo samples, as well as a preparation for upcoming lunar sample return missions (e.g., Artemis). The work began with studies of unsealed core tube 73002 [1,2] that is the upper ~35 cm of an Apollo 17 double drive tube (~70 cm total depth) collected on the landslide deposit near Lara Crater at Station 3 in the Taurus Littrow Valley. More recently the program extended to the study of a variety of frozen Apollo 17 samples [3], as well as the gas extraction [4] and dissection [5] of 73001, the lower half of the station 3 double drive tube. Sample 73001 was sealed under vacuum on the Moon in a Core Sample Vacuum Container (CSVC). In this abstract we will examine the role of X-ray Computed Tomography (XCT) during the preliminary examination process for sealed core 73001, including: (1) engineering scans to aid in understanding the gas extraction process, (2) whole-core scanning prior to opening to inform extrusion and dissection work, and (3) individual particle scanning to characterize rock fragment lithologies for follow on studies. Methodology: Sample 73001 is a 33 cm long, 4 cm diameter regolith sample collected inside a lunar drive tube (~1 mm aluminum walls). That drive tube was sealed inside a 0.5 mm thick stainless steel (SS) CSVC. XCT scans for engineering purposes were done on the Nikon XTH 320 system at Johnson Space Center using the 225 kV multi-metal reflection source at 215 kV, 179 A, and a 38.49 m voxel size. Individual >4 mm particles separated from the core during processing (then triply sealed in Teflon bags) were also scanned at JSC using the 180 kV source at 90 kV, 33 A, and a 2.98 – 10.65 m voxel size. Whole-core scans were done at the University of Texas High-Resolution X-ray Computed Tomography Facility (UTCT) on the 225 kV reflection source on the North Star Imaging cabinet XCT system. These scans included: (1) a series of 9 overlapping super-resolution scans each covering a ~4 cm length of the tube at 190 kV, 180 µA, and a 12.9 µm voxel size and (2) a lower resolution continuous helical scan of the entire core at 190 kV, 180 µA, and a 51.8 µm voxel size. Progress and Results: Before piercing and extracting the gas from sample 73001, an XCT scan of the bottom portion of the CSVC was used to confirm the location of the Teflon cap on the inner drive tube and whether there was an “air” gap between the Teflon cap and the CSVC. This was to ensure the Teflon cap (which immobilized the soil inside the drive tube) was not accidentally pierced during gas extraction. Similarly, after piercing, the bottom and top portions of the CSVC were scanned in order to capture engineering knowledge about the results of the piercing process, as well as the metal knife edge vacuum seal (SS into an In-Ag alloy). Both scans will provide constraints on future work of this type, both for the design of tools used on the lunar surface during Artemis, as well as how we open future samples of this type. An unexpected finding from these engineering scans was that the device in the drive tube that immobilizes the regolith (the keeper) was not seated in the tube properly. This meant that (1) the drive tube could not be removed from the CSVC for the trip to UTCT, and (2) the procedure for opening and extruding the drive tube had to be modified. Had either of these things not been known prior to opening the CSVC, it could have led to an inability to XCT scan the whole core at high resolution and/or potential disruption of the core stratigraphy during extrusion. At UTCT, the entire length of the core was scanned at high resolution (12.9 microns per voxel). This scan serves multiple purposes: (1) A lower resolution (and uncorrected) version of these scans stitched together was used to help inform the processors of potential pitfalls during extrusion and dissection (voids, angular fragments at the edges of the sample, etc.); and (2) the full resolution corrected data will serve as the permanent in situ record of the stratigraphy of the sample and will enable future researchers to perform a variety of analyses. All 121 >4 mm particles separated during dissection pass 1 of sample 73001 have been individually scanned. These scans clearly show the lithology of each particle while keeping the particles in pristine condition (they are individually triply bagged in Teflon within our N2 purged processing cabinets). Because of the dust adhering to particle exteriors, it would otherwise be impossible to determine lithologies in a non-contaminating way. Thus far the types of lithologies seen in sample 73001 (e.g., regolith breccias, impact-melt breccias, agglutinates, and bas-alts) are similar to those previously identified in sample 73002 [2]. By the time of the meeting, all particles from all 3 dissection passes will have been scanned and statistics on the different lithologies in 73001 compiled. References: [1] Shearer et al. (2020) 51st LPSC, abstract 1181. [2] Zeigler et al. (2020) 51st LPSC, abstract 3023. [3] Kent et al. (2022) This Volume. [4] McDonald et al. (2022) European Lunar Symposium. [5] Gross et al (2022) This volume.

Moon↗

Comparison of aortic and carotid baroreflex stimulus-response characteristics in humans

In order to characterize the stimulus-response relationships of the arterial, aortic, and carotid baroreflexes in mediating cardiac chronotropic function, we measured heart rate (HR) responses elicited by acute changes in mean arterial pressure (MAP) and carotid sinus pressure (CSP) in 11 healthy individuals. Arterial (aortic + carotid) baroreflex control of HR was quantified using ramped changes in MAP induced by bolus injection of phenylephrine (PE) and sodium nitroprusside (SN). To assess aortic-cardiac responses, neck pressure (NP) and suction (NS) were applied during PE and SN administration, respectively, to counter alterations in CSP thereby isolating the aortic baroreflex. Graded levels of NP and NS were delivered to the carotid sinus using a customized neck collar device to assess the carotid-cardiac baroreflex, independent of drug infusion. The operating characteristics of each reflex were determined from the logistic function of the elicited HR response to the induced change in MAP. The arterial pressures at which the threshold was located on the stimulus-response curves determined for the arterial, aortic and carotid baroreflexes were not significantly different (72+/-4, 67+/-3, and 72+/-4 mm Hg, respectively, P > 0.05). Similarly, the MAP at which the saturation of the reflex responses were elicited did not differ among the baroreflex arcs examined (98+/-3, 99+/-2, and 102+/-3 mm Hg, respectively). These data suggest that the baroreceptor populations studied operate over the same range of arterial pressures. This finding indicates each baroreflex functions as both an important anti-hypotensive and anti-hypertensive mechanism. In addition, this investigation describes a model of aortic baroreflex function in normal healthy humans, which may prove useful in identifying the origin of baroreflex dysfunction in disease- and training-induced conditions.

Non-NASA Center↗

ISS Squat and Deadlift Kinematics on the Advanced Resistive Exercise Device

Visual assessment of exercise form on the Advanced Resistive Exercise Device (ARED) on orbit is difficult due to the motion of the entire device on its Vibration Isolation System (VIS). The VIS allows for two degrees of device translational motion, and one degree of rotational motion. In order to minimize the forces that the VIS must damp in these planes of motion, the floor of the ARED moves as well during exercise to reduce changes in the center of mass of the system. To help trainers and other exercise personnel better assess squat and deadlift form a tool was developed that removes the VIS motion and creates a stick figure video of the exerciser. Another goal of the study was to determine whether any useful kinematic information could be obtained from just a single camera. Finally, the use of these data may aid in the interpretation of QCT hip structure data in response to ARED exercises performed in-flight. After obtaining informed consent, four International Space Station (ISS) crewmembers participated in this investigation. Exercise was videotaped using a single camera positioned to view the side of the crewmember during exercise on the ARED. One crewmember wore reflective tape on the toe, heel, ankle, knee, hip, and shoulder joints. This technique was not available for the other three crewmembers, so joint locations were assessed and digitized frame-by-frame by lab personnel. A custom Matlab program was used to assign two-dimensional coordinates to the joint locations throughout exercise. A second custom Matlab program was used to scale the data, calculate joint angles, estimate the foot center of pressure (COP), approximate normal and shear loads, and to create the VIS motion-corrected stick figure videos. Kinematics for the squat and deadlift vary considerably for the four crewmembers in this investigation. Some have very shallow knee and hip angles, and others have quite large ranges of motion at these joints. Joint angle analysis showed that crewmembers do not return to a normal upright stance during squat, but remain somewhat bent at the hips. COP excursions were quite large during these exercises covering the entire length of the base of support in most cases. Anterior-posterior shear was very pronounced at the bottom of the squat and deadlift correlating with a COP shift to the toes at this part of the exercise. The stick figure videos showing a feet fixed reference frame have made it visually much easier for exercise personnel and trainers to assess exercise kinematics. Not returning to fully upright, hips extended position during squat exercises could have implications for the amount of load that is transmitted axially along the skeleton. The estimated shear loads observed in these crewmembers, along with a concomitant reduction in normal force, may also affect bone loading. The increased shear is likely due to the surprisingly large deviations in COP. Since the footplate on ARED moves along an arced path, much of the squat and deadlift movement is occurring on a tilted foot surface. This leads to COP movements away from the heel. The combination of observed kinematics and estimated kinetics make squat and deadlift exercises on the ARED distinctly different from their ground-based counterparts. CONCLUSION This investigation showed that some useful exercise information can be obtained at low cost, using a single video camera that is readily available on ISS. Squat and deadlift kinematics on the ISS ARED differ from ground-based ARED exercise. The amount of COP shift during these exercises sometimes approaches the limit of stability leading to modifications in the kinematics. The COP movement and altered kinematics likely reduce the bone loading experienced during these exercises. Further, the stick figure videos may prove to be a useful tool in assisting trainers to identify exercise form and make suggestions for improvements

Newby, N.↗

Lumbar spine disc height and curvature responses to an axial load generated by a compression device compatible with magnetic resonance imaging

STUDY DESIGN: Axial load-dependent changes in the lumbar spine of supine healthy volunteers were examined using a compression device compatible with magnetic resonance imaging. OBJECTIVE: To test two hypotheses: Axial loading of 50% body weight from shoulder to feet in supine posture 1) simulates the upright lumbar spine alignment and 2) decreases disc height significantly. SUMMARY OF BACKGROUND DATA: Axial compression on the lumbar spine has significantly narrowed the lumbar dural sac in patients with sciatica, neurogenic claudication or both. METHODS: Using a device compatible with magnetic resonance imaging, the lumbar spine of eight young volunteers, ages 22 to 36 years, was axially compressed with a force equivalent to 50% of body weight, approximating the normal load on the lumbar spine in upright posture. Sagittal lumbar magnetic resonance imaging was performed to measure intervertebral angle and disc height before and during compression. RESULTS: Each intervertebral angle before and during compression was as follows: T12-L1 (-0.8 degrees +/- 2.5 degrees and -1.5 degrees +/- 2.6 degrees ), L1-L2 (0.7 degrees +/- 1.4 degrees and 3.3 degrees +/- 2.9 degrees ), L2-L3 (4.7 degrees +/- 3.5 degrees and 7.3 degrees +/- 6 degrees ), L3-L4 (7.9 degrees +/- 2.4 degrees and 11.1 degrees +/- 4.6 degrees ), L4-L5 (14.3 degrees +/- 3.3 degrees and 14.9 degrees +/- 1.7 degrees ), L5-S1 (25.8 degrees +/- 5.2 degrees and 20.8 degrees +/- 6 degrees ), and L1-S1 (53.4 degrees +/- 11.9 degrees and 57.3 degrees +/- 16.7 degrees ). Negative values reflect kyphosis, and positive values reflect lordosis. A significant difference between values before and during compression was obtained at L3-L4 and L5-S1. There was a significant decrease in disc height only at L4-L5 during compression. CONCLUSIONS: The axial force of 50% body weight in supine posture simulates the upright lumbar spine morphologically. No change in intervertebral angle occurred at L4-L5. However, disc height at L4-L5 decreased significantly during compression.

Non-NASA Center↗

TOWARD A METHOD FOR SCALING HUMAN BODY MODELS IN AN IMU-BASED WORKFLOW

BACKGROUND Scaled biomechanical models can more accurately inform crew health decisions when tailored to the wide range of astronaut sizes. One component to improve scaling of existing models to better represent each unique astronaut’s size is the individual length scaling of limbs. Traditionally, these lengths are determined by motion capture or manual measurement. A new method is herein proposed for length scaling which can be done by measuring linear and angular accelerations at a desired point during isolated motion around a point of rotation, then calculating the distance between the desired point and point of rotation. When an Inertial Measurement Unit (IMU) device is placed at the distal point of a limb, the isolated motion is about that limb’s proximal joint. For example, to measure forearm length, an IMU is placed at the wrist, the point of rotation is at the elbow, and the isolated motion is forearm flexion and extension. These calculated lengths are then used to scale models to each unique astronaut’s size, thereby improving the applicability of the model. This method of scaling limb segments can be used for any limb that has an easily defined proximal joint for the limb to rotate around including hands, arms, legs, feet. Utilizing IMUs for data collection also provides the synergistic ability to record data without a dedicated space in a room with many cameras, therefore reducing the data collection footprint, or record data where optical motion capture is not possible, such as inside a spacesuit. METHODS AND RESULTS To test this method, upper body data collection was performed with 5 Xsens DOT IMUs on a single subject. IMUs consist of an accelerometer, a gyroscope, and a magnetometer which collect linear acceleration, angular velocity, and magnetic fluctuations, respectively. Before any ground-based laboratory collection, the magnetic fluctuations are used to correct the heading of the IMU in space relative to the Earth’s magnetic field. The direct measurement of angular velocity is integrated to calculate angular acceleration. Then the linear acceleration ( a ) and angular acceleration (α) are solved using r = at/α to calculate the radius, which in this case is the distance between the IMU and the point of rotation (i.e., segment length). The IMU must be placed at the most distal point of the limb being measured (i.e., ankle if measuring lower leg length) and the test plan must consist of an isolated motion about that limb’s proximal joint (i.e., knee flexion and extension if measuring lower leg length). The distances (radii) calculated at every time interval were filtered (bandpass filter keeping 5th-90th percentile data) to eliminate outliers and spurious data that occur when the isolated motion was stopped or nearly stopped. The remaining distances were averaged, resulting in the calculated limb length. Scaling factors were then computed by dividing the calculated limb length by the unscaled model’s length. These scale factors are plugged into the Scale Tool in OpenSim [1,2] to apply the scaling to the OpenSim Full Body Rajagopal Model [3,4]. Manual measurements of limb lengths were taken before data collection started and used for comparing against the calculated lengths. The Anthropometric Survey of US Army Personnel (ANSUR II) [5] was also used as a third source of reference for limb length measurements. The following measurements were retrieved from the subject before data collection: 34.5 cm from L1 to C7 (thorax), 25.7 cm from C7 Joint Center (JC) to head vertex (neck and head), 36.3 cm from shoulder JC to elbow JC (humerus), 29.5 cm from elbow JC to wrist JC (forearm), and 16.2 cm from clavicle to acromion (clavicle). Of those five, forearm and humerus lengths were calculated using this proposed method to obtain preliminary results. The forearm length after filtering and averaging was calculated to be 37.6 cm. This is a 28% overestimation from the measured forearm length (29.5 cm). The humerus length after filtering and averaging was calculated to be 47.8 cm. This is a 31% difference from the measured subject length (36.3 cm). Sources of error include imperfect isolated motion (method currently expects that motion should be perfectly circular in a 2D plane, include no rotation of the IMU, and be relatively smooth; a more secure IMU attachment method will help), unrefined filter techniques (removed highest and lowest values with 20% high and low pass filters and no smoothing filters), arbitrary removal of stopped or near stopped data (kept data for only a short range before and after the angular velocity peaking), and a more representative method for removing gravitational acceleration is needed (current method is to zero all accelerations against a baseline taken just before the isolated motion which does not account for the gravitational acceleration changed due to IMU rotation during movement). Addressing these error sources will improve the accuracy of the limb length calculation. Next steps include creating a method for whole-body scaling estimation using individual limb scale factors. Continued pursuit of these techniques is expected to enable acquiring anthropometric information using only IMUs in real-time.

E. K. Marecki↗

Evaluating The Relationships Between Supine Propriorception Assessments with Upright Functional Mobility and Balance Tests

INTRODUCTION Upon return to Earth, spaceflight sensorimotor adaptations can result in impaired posture and locomotion [1], [2], and current exercise countermeasures in the International Space Station are not sufficient to maintain sensorimotor function. In-flight countermeasures and assessment tools for sensorimotor function are needed to mitigate risks associated with mission-critical task performance upon return to Earth or arrival to 0.38 G on Mars. One proposed countermeasure for proprioceptive deconditioning includes training on a tilt board device [3], which will be tested in an upcoming bed rest study. In preparation for the said study, the objective of this pilot study is to compare performance in supine proprioceptive assessments to performance in functional upright activities. The results are intended to guide the selection of supine assessment tools for the upcoming bedrest study and the development of future inflight proprioceptive training and assessment tools for exploration missions. METHODS Seventeen healthy participants (8 males and 9 females, 27.9 ± 8.5 years) provided informed consent as approved by the Institutional Review Board (IRB) at NASA. A horizontal air-bearing sled was used to provide a proprioceptive challenge in a supine body orientation, allowing for mediolateral motion with minimal friction during supine stance [4]. Participants were loaded axially (30 to 60% body weight) with their feet on a vertically oriented tilt board and instructed to perform supine assessment activities using custom software that displays a cursor controlled by tilting the tilt board. In a single-leg static activity on the tilt board (TB-St), performance was measured as the percent time spent on a center target during a 30-second trial. During a two-feet dynamic activity on the tilt board (TB-Dy), performance was measured as the number of targets captured in 30 seconds. These supine tasks were compared to performance during two upright activities used to represent upright performance: completion time for a functional mobility task (FMT) [2],[5] and a performance score from force plate sway data during 30-second single-leg upright standing (USL). RESULTS AND DISCUSSION A Spearman's rank-order correlation was run to assess the relationship between upright and supine assessments. There were statistically significant, strong correlations between scores for the FMT and each TB activity, including TB-St, rs(17) = 0.50, p<0.05, TB-Dy3, rs(17) = 0.73, p<0.001, and TB-Dy9, rs(15) = 0.53, p<0.05. There were no statistically significant correlations between USL and each TB activity. Despite a lack of correlation with upright single-leg balance, the ability of the TB to indicate upright performance in the FMT is promising, as this task is a standard post-flight measure designed to characterize locomotor dysfunction [2], [5]. CONCLUSION These efforts will inform the selection of an appropriate sensorimotor assessment method for the upcoming bed rest study and similar future studies. While current work uses a bed rest analog to develop these technologies, future work aims to prepare capabilities for future in-flight sensorimotor training and assessment to mitigate the risks of proprioception impairment after spaceflight. ACKNOWLEDGEMENTS This work was supported by the University Space Research Association Internship Program. REFERENCES [1] Mulavara A.P. et al (2018) Med Sci Sports Exerc, 50(9), 1961-1980. [2] Mulavara A.P. et al (2010) Exp Brain Res, 202(3), 649-659. [3] Macaulay T.R. et al (2021) Front. Syst. Neurosci., 15, 658-985. [4] Goel R. et al (2017) Front. Syst. Neurosci, 11. [5] Koppelmans V. et al (2013) BMC Neurology, 12.

R Bellisle↗

Chapter 19B - Antenna Radiation Patterns

Modern civil and military aircraft are equipped with a variety of communication devices, radio navigation equipment, and air traffic control systems. For all of these devices appropriate antennas must be available to transmit and receive the signals. As a result, as many as 30 antennas, and sometimes even more, are mounted around today's aircraft. For this reason, it is necessary to know the capabilities of the receiving/transmitting equipment on board. These capabilities are driven by the antenna characteristics. Therefore, coverage, shading, and beam pointing pattern data are necessary for optimum electronic coverage. The aircraft antenna has to convert the available power density of the electromagnetic field to an electric voltage at its connector. This voltage level must be sufficiently high to operate the connected equipment. The reciprocity principle states that it makes no difference if the antenna is receiving or transmitting. For the certification of the aircraft antennas it must be proven that the antennas are at least generating the minimum receiver input voltage which is required for each radio service. The prime condition is, of course, that the specified field power densities of the different radio navigation and communication services are available. An important property of a radio frequency link is the electro-magnetic field intensity at every point in space for a given output power of the antenna. As the propagation of radio frequency waves in free space is well known, the spatial distribution of the field intensity needs only be measured at one spatial sphere around the antenna. The information is usually given as distributions along the circumference of flat sections through this sphere: each of these is called an ARP. Several ARPs are usually required to describe the complete spatial antenna pattern of an antenna. In addition to mathematical modeling, measurements on sub-scale models, and static measurements on full size models or aircraft on the ground, dynamic measurements on aircraft in flight play the most important role in the aircraft antenna testing and certification. [19B-1] The shape of an ARP, for one given frequency, is determined by the shape of the antenna and the shape and material of the surface it is mounted on. As the directly transmitted waves interfere with waves reflected by the aircraft skin with its complex geometry, and the surface material parameters are only roughly known, it is not possible to predict the ARP with the required accuracy. In ground measurements the earth's surface also acts as a reflector thereby causing the ground ARP to be different from the in-flight ARP. As the in-flight ARP is the ARP we are actually interested in it becomes clear that it is necessary to conduct in-flight ARP measurements. The Flight Test Engineer must be aware of the needs of the specialists who are establishing the test program for measuring antenna patterns and radar cross sections. These tests will require special test equipment and dedicated flights to obtain the data that they require. This Section provides an introduction to the principles of determining antenna patterns and the flight techniques for determining both antenna patterns and radar cross section. Reference 19B-1 provides detailed information.

Helmut Bothe↗

Quantum-Assisted Variational Segmentation for Image-to-Image Wildfire Detection Using Satellite Data

The quantum computing community has been searching for suitable applications to demonstrate the potential of near-term quantum devices. Quantum machine learning is a potential candidate, particularly using models that cannot be efficiently simulated with classical computers [1, 2]. This work focuses on a transition phase of quantum computers where the quantum machine learning model is still simulable classically but projected not to be simulable as the size of the model grows. Ultimately quantum computers may have advantages for high-dimensional real-world problems. Due to the limited number of qubits in current noisy intermediate-scale quantum (NISQ) devices, the direct application of quantum computers in high dimensional data is not feasible. To remedy this problem, an encoder-decoder architecture can be utilized. The encoder model would transform the high-dimensional data into a compact representation, to a level that small quantum computers can be used today (or in the near future), and the decoder would take the quantum processed outputs back to the high-dimensional space. Addressing the two challenges of quantum machine learning, this work investigates a hybrid supervised generative model with a quantum Ising Born machine embedded as the latent distribution. The model contains four main parts (Figure 1.a.): (1) a U-NET architecture responsible for learning segmentation flow, (2) a Prior network responsible for learning an encoded latent distribution of the input data, (3) a Born machine which represents the latent distribution, and (4) a Posterior network in charge of learning the joint encoded latent distribution of inputs and target data. The initial model, proposed by [3], is optimized by (1) maximizing the overlap of the prior and posterior latent distributions, and (2) minimizing the segmentation loss. The proposed model is designed to be investigated in a simulation environment applied to the real-world application of wildfire segmentation. Specifically, the model is designed to solve the patchy wildfire segmentations of Moderate Resolution Imaging Spectroradiometer (MODIS) by taking the MODIS observations and using Visible Infrared Imaging Radiometer Suite’s (VIIRS) consistent wildfire product as the target. The model solves patchy wildfire segmentations and provides insight into the epistemic errors sourced from model variation. The model utilizes the Born machine as a QUBO solver to represent the latent space as a Bernoulli distribution. The proposed configuration allows the variational segmentation model to leverage the true quantum probabilistic nature and derive a more expressive latent configuration, increasing the model performance in describing wildfire segmentations. The quantum probabilistic information of the Born machine is directly incorporated in the Kullback-Leibler divergence loss in the prior and posterior distributions, forcing the Bernoulli latent distribution to maximize the overlap of input and joint input-target distributions. The proposed model is then trained and compared with a baseline only consisting of direct Bernoulli latent distribution with no Born machine representing the latent space. The models are evaluated based on the segmentation metrics, such as precision, recall, intersect of union, with uncertainty boundaries accounting for the stochastic nature of the model. Our findings show that even in low latent-dimensional space (due to the limit in computational power of the classical quantum simulator), we are able to effectively capture the latent representation and hence the model performs better than the baseline. The findings are a projection for scaling the model into higher dimensional latent space with the Born machine surpassing the baseline performance. Figure 1. Sub-figure (a) demonstrates the architecture for the training phase. The model consists of a Prior and Posterior network that encode inputs and joint input-target data into compact representations, respectively. The Born machine represents the latent distribution, and the U-NET branch learns the segmentation patterns of the data. The stochasticity is introduced to the U-NET through its last layer to create meaningful but stochastic segmentations. Sub-figure (b) represents the inference phase where the model takes the stochastic behavior from the prior network and injects that into the U-NET. Each attempt of inference will generate different but similar segmentations from the same distribution of the wildfire event. REFERENCES [1] Coyle, B., Mills, D., Danos, V., & Kashefi, E. (2020). The Born supremacy: quantum advantage and training of an Ising Born machine. npj Quantum Information, 6(1), 1-11. [2] Liu, J. G., & Wang, L. (2018). Differentiable learning of quantum circuit born machines. Physical Review A, 98(6), 062324. [3] Kohl, S., Romera-Paredes, B., Meyer, C., De Fauw, J., Ledsam, J. R., Maier-Hein, K., ... & Ronneberger, O. (2018). A probabilistic u-net for segmentation of ambiguous images. Advances in neural information processing systems, 31.

quantum machine learning↗

EVA Swab Kit: Tools and Techniques for Collecting Aseptic Samples from Crewed Space Missions

Introduction: When we send humans to search for life on other planets, we'll need to know what we brought with us versus what may already be there. To ensure our crewed spacecraft meet planetary protection requirements—and to protect our science from human contamination—we'll need to assess and verify whether micro-organisms may be leaking/venting from our spacesuits. This requires collecting samples under Extravehicular Activity (EVA) conditions. Detailed, systematic research on forward contamination from robotic spacecraft has been steadily progressing since the Viking missions, but systematic studies of contamination from space suits has not been conducted in many years. The modern EMU (Extravehicular Mobility Unit) suit used by NASA is designed to leak at rates as high as 100 cc/min. Before humans land on Mars there is a critical need to understand the types and quantities of microbes that could be introduced via space suits. The Human Forward Contamination Assessment team at NASA’s Johnson Space Center (JSC) has developed a prototype EVA swab tool [1,2,3,4] designed for use in space to sample cleaned and uncleaned space suits to determine the present day microbial load and eventually the rate of leakage. The ability to assess microbial leakage early in advanced space suit and life support system design cycles will help avoid costly hardware redesign later. Test Objectives: The primary objective of EMU testing was to characterize the type of micro-organisms typically found on or near selected suit pressure joints under suit differential pressure conditions. Most human-borne microbes can fit through a 0.5 to 1.0 µm gap. Knowing which joints are more likely to leak will inform hardware design decisions. Knowing which types of micro-organisms may leak from EVA suits provides a basis for subsequent studies to characterize the viability of those organisms under destination conditions, as well as how far they might spread through natural or human-influenced processes. That data, in turn, will inform exploration mission operations and hardware design. The secondary objective of testing was to evaluate the interface between a fully suited test subject and the EVA swab tool at vacuum. Bulky EVA suits can restrict movement and limit visibility through the helmet visor. Fully suited testing is important for identifying tool design issues prior to flight. At exploration destinations, such as Mars, suited crew may be required to periodically sample their suits as part of an environmental monitoring protocol. Suit Microbial Sampling Results: This report details results of microbial swabs collected from current flight suit configurations worn by crew members assigned to upcoming ISS expedition missions as well as swabs collected from prototype suits intended for use on the Orion spacecraft. These tests were intended to characterize the types of contaminants found on flight suits under current, typical handling conditions. No attempt was made to change suit handling procedures, provide additional sterilization, or to limit typical potential contaminant sources. Using culture based techniques, we cultivated 235 CFU (colony forming units) comprised of 26 bacterial species and one fungal species on the outside of the suits. The fungal species and 14 of the bacterial species were unique to the suit surfaces and were not detected in any of the background samples collected within the chambers. We sequenced 755,434 ribosomal fragments on all of the suit surfaces from swab samples. 557,016 of these sequences represent DNA that survived at least 4 hours at vacuum. These sequences formed 2,464 OTU's (Operational Taxonomic Units, 97% similarity) showing low diversity in the samples. The most abundant sequences that survived vacuum belong to the genera Staphyloccocus, Ralstona, Bacillus and Rhodobacter all of which are common to the human microbiome. [5] See Danko et al., (2021) for more complete details of these first analyses. Further analysis of EVA suit materials with respect to the efficacy of various cleaning protocols and engineered containment solutions is planned to inform suit design for NASA’s Artemis Moon to Mars program crew testing. Swab Tool Function Results: The kit was demonstrated for fit and function in suited subject vacuum tests to determine how well the tool worked as an aseptic microbial sampling device as well as to identify any design elements that could be upgraded for EVA task specific improvement. It was found that sample acquisition efficacy could be enhanced by redesign of the sample canister to end-effector interface. Several modifications of the sample caddy assemblies to optimize EVA safety and functionality were also identified. Consequently, fabrication of the redesigned sample canister to end-effector assembly interfaces and and the sample caddy assemblies are required. Fabrication of sixteen flight sample canister assemblies (8 per each of two EVA Swab Kits) and two sample caddy assemblies are in process to be followed by hardware testing and certification to produce two flight-certified EVA Swab Kits for transport to ISS no earlier than summer of 2022. Sampling Strategy: The International Space Station is an ideal testbed for systematic studies of contamination from crewed vehicles since it has been continuously occupied for 20 years and exposed to non-terrestrial conditions. We will sample the exterior of the ISS during EVA using a purpose-built swab tool capable of maintaining sterility while undergoing temperature changes from -151 to +121°C under hard vacuum. Prior to each EVA, the project team will work with ISS mission managers to identify precise sampling locations, which will vary by EVA based on the translation paths and worksites scheduled for that particular EVA. Ideally, translation path handrails and areas near ECLSS (Environmental Control and Life Support System) external vent openings on a spacecraft would be assessed. There are currently more than a dozen ECLSS external vents on the ISS. Some are connected to systems that vent waste products, while others are intended to equalize cabin pressure. As EVA opportunity allows, microbial samples from any of these external vents would provide a valuable data point, though some will be more useful than others. Four criteria have been identified to help prioritize sampling sites near vents: • EVA Accessibility: To minimize cost, it is desired to piggy-back onto a planned EVA. Therefore, the sampling location must be readily accessible by an EVA crew • Type of Vented Products: Vent products that have been in direct contact with crew, such as cabin air, are more likely to contain microorganisms than vent products associated with isolated systems, such as experiment module combustion products. • Mass of Vented Products: Higher-flow vents are more likely to contain detectible levels of microbial contaminants than lower-flow vents. • Local Environment: Sample locations with relatively benign local conditions, such as warm surfaces shielded from direct ultraviolet (UV) radiation exposure, may be more likely to support microbial growth than locations with harsher local environmental conditions. Because EVA accessibility is the most important criteria, the proposal team worked with an astronaut and flight controllers using the Dynamic Onboard Ubiquitous Graphics (DOUG) tool. The DOUG virtual environment allows an operator to “fly” around the current ISS vehicle configuration to assess EVA translation paths, attach points, and keep-out zones. While analysis on station or rapid return to Earth would be preferable, samples collected from the exterior of the ISS have already been exposed to temperature variations between -157 and +121 °C as well as hard vacuum. Therefore, they should be fairly stable and robust. We hypothesize that samples collected from the ISS exterior could be stored for up to 6 months at -80°C without degradation. Sample canisters will be returned to Earth while frozen at -80°C for analysis, and sterilized canisters can be re-flown back to ISS to support additional sampling opportunities Relevance to NASA Exploration Objectives: These data will allow us to identify new or improved methods, technologies, and procedures for spacecraft sterilization and leakage mitigation to minimize the amount of contamination introduced to the environment by human explorers. This work is funded by NASA research grant: NNH18ZDA001N-PPR References: [1] Bell, M.S. et al. (2015) LPS XLVI, Abst. #1832 [2] Rucker et al. (2018) 42nd COSPAR (PPP.3) [3] Bell, M.S. et al. (2019) Mars Extant Life Conference, Abst. #5096.[4] Bell, M.S. et al., (2020) 43rd COSPAR (BO.2).[5] Danko D, et.al.,(2021)Front.Microbiol.12:608478.

Mary Suzanne Bell↗