Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Results of a Self-Absorption Study on the Versapor 3000 47-mm Filters for Radioactive Particulate Air Stack Sampling

Since the mid-1980s the Pacific Northwest National Laboratory (PNNL) has used a value of 0.85 as a correction factor for the self absorption of activity for particulate radioactive air samples collected from building exhaust for environmental monitoring. More recently, an effort was made to evaluate the current particulate radioactive air sample filters (Versapor® 3000, 47-mm diameter) used at PNNL for self absorption effects. There were two methods used to characterize the samples. Sixty samples were selected from the archive for acid digestion to compare the radioactivity measured by direct gas-flow proportional counting of filters to the results obtained after acid digestion of the filter and counting again by gas-flow proportional detection. Thirty different sample filters were selected for visible light microscopy to evaluate filter loading and particulate characteristics. Mass-loading effects were also considered. Large error is associated with the sample filter analysis comparison and subsequently with the estimation of the absorption factor resulting in an inadequate method to estimate losses from self-absorption in the sample filter. The mass loading on the sample filter as determined after digestion and drying was ~0.08 mg cm-2; however, this value may not represent the total filter mass loading given that there may be undetermined losses associated with the digestion process. While it is difficult to determine how much material is imbedded in the filter, observations from the microscopy analysis indicate that the vast majority of the particles remain on the top of the filter. In comparing the results obtained, the continued use of 0.85 as a conservative correction factor is recommended.

correction factors↗

DISTRIBUTION COEFICIENTS (KD) GENERATED FROM A CORE SAMPLE COLLECTED FROM THE SALTSTONE DISPOSAL FACILITY

Core samples originating from Vault 4, Cell E of the Saltstone Disposal Facility (SDF) were collected in September of 2008 (Hansen and Crawford 2009, Smith 2008) and sent to SRNL to measure chemical and physical properties of the material including visual uniformity, mineralogy, microstructure, density, porosity, distribution coefficients (K{sub d}), and chemical composition. Some data from these experiments have been reported (Cozzi and Duncan 2010). In this study, leaching experiments were conducted with a single core sample under conditions that are representative of saltstone performance. In separate experiments, reducing and oxidizing environments were targeted to obtain solubility and Kd values from the measurable species identified in the solid and aqueous leachate. This study was designed to provide insight into how readily species immobilized in saltstone will leach from the saltstone under oxidizing conditions simulating the edge of a saltstone monolith and under reducing conditions, targeting conditions within the saltstone monolith. Core samples were taken from saltstone poured in December of 2007 giving a cure time of nine months in the cell and a total of thirty months before leaching experiments began in June 2010. The saltstone from Vault 4, Cell E is comprised of blast furnace slag, class F fly ash, portland cement, and Deliquification, Dissolution, and Adjustment (DDA) Batch 2 salt solution. The salt solution was previously analyzed from a sample of Tank 50 salt solution and characterized in the 4QCY07 Waste Acceptance Criteria (WAC) report (Zeigler and Bibler 2009). Subsequent to Tank 50 analysis, additional solution was added to the tank solution from the Effluent Treatment Project as well as from inleakage from Tank 50 pump bearings (Cozzi and Duncan 2010). Core samples were taken from three locations and at three depths at each location using a two-inch diameter concrete coring bit (1-1, 1-2, 1-3; 2-1, 2-2, 2-3; 3-1, 3-2, 3-3) (Hansen and Crawford 2009). Leaching experiments were conducted with a section of core sample 3-2. All cores from location 3 were drilled without using water. Core sample 3-2 was drilled from approximately six inches to a depth of approximately 13 inches. Approximately six inches of the core was removed but it broke into two pieces during removal from the bit. At the time of drilling, core material appeared olive green in color (Smith 2008). The fact that the samples were cored as olive green and were received after storage with a gray outer layer is indicative that some oxidation had occurred prior to leaching studies.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sampling Point Compliance Tests for 325 Building at Set-Back Flow Conditions

The stack sampling system at the 325 Building (Radiochemical Processing Laboratory [RPL]) was constructed to comply with the American National Standards Institute’s (ANSI’s) Guide to Sampling Airborne Radioactive Materials in Nuclear Facilities (ANSI N13.1-1969). This standard provided prescriptive criteria for the location of radionuclide air-sampling systems. In 1999, the standard was revised (Sampling and Monitoring Releases of Airborne Radioactive Substances From the Stacks and Ducts of Nuclear Facilities [ANSI/Health Physics Society [HPS] 13.1-1999]) to provide performance-based criteria for the location of sampling systems. Testing was conducted for the 325 Building stack to determine whether the sampling system would meet the updated criteria for uniform air velocity and contaminant concentration in the revised ANSI/HPS 13.1-1999 standard under normal operating conditions (Smith et al. 2010). Measurement results were within criteria for all tests. Additional testing and modeling was performed to determine whether the sampling system would meet criteria under set-back flow conditions. This included measurements taken from a scale model with one-third of the exhaust flow and computer modeling of the system with two-thirds of the exhaust flow. This report documents the results of the set-back flow condition measurements and modeling. Tests performed included flow angularity, uniformity of velocity, gas concentration, and particle concentration across the duct at the sampling location. Results are within ANSI/HPS 13.1-1999 criteria for all tests. These tests are applicable for the 325 Building stack under set-back exhaust flow operating conditions (980 - 45,400 cubic feet per minute [cfm]) with one fan running. The modeling results show that criteria are met for all tests using a two-fan configuration exhaust (flow modeled at 104,000 cfm). Combined with the results from the earlier normal operating conditions, the ANSI/HPS 13.1-1999 criteria for all tests are met for all configurations: one, two, or three fans (normal).

air sampling↗

Improving the sampling efficiency of the Grand Canonical Simulated Quenching approach

Most common atomistic simulation techniques, like molecular dynamics or Metropolis Monte Carlo, operate under a constant interatomic Hamiltonian with a fixed number of atoms. Internal (atom positions or velocities) or external (simulation cell size or geometry) variables are then evolved dynamically or stochastically to yield sampling in different ensembles, such as microcanonical (NVE), canonical (NVT), isothermal-isobaric (NPT), etc. Averages are then taken to compute relevant physical properties. At least two limitations of these standard approaches can seriously hamper their application to many important systems: (1) they do not allow for the exchange of particles with a reservoir, and (2) the sampling efficiency is insufficient to allow the obtention of converged results because of the very long intrinsic timescales associated with these quantities. To fix ideas, one might want to identify low (free) energy configurations of grain boundaries (GB). In reality, grain boundaries are in contact the grains which act as reservoirs of defects (e.g., vacancies and interstitials). Since the GB can exchange particles with its environment, the most stable configuration cannot provably be found by sampling from NVE or NVT ensembles alone: one needs to allow the number of atoms in the sample to fluctuate. The first limitation can be circumvented by working in the grand canonical ensemble (TV ) or its derivatives (such as the semi-grand-canonical ensemble useful for the study of substitutional alloys). Monte Carlo methods have been the first to adapt to this kind of system where the number of atoms is allowed to fluctuate. Many of these methods are based on the Widom insertion method [Widom63] where the chemical potential of a given chemical species can be inferred from the potential energy changes upon random insertion of a new particle within the simulation cell. Other techniques, such as the Gibbs ensemble Monte Carlo [Panagiotopoulos87] where exchanges of particles are attempted to equilibrate the chemical potential between two cells and hence allow for the calculation of coexistence curves, exploit the same idea: particle insertion (or exchange) is attempted and accepted with a Metropolis-like rule that depends exponentially on the energy change upon insertion. A well known limitation of this kind of approach is that the probability of accepting such a move decreases extremely rapidly with increasing density, due to the extremely large short-range repulsion between atoms. In response to these difficulties it became apparent that a solution to the problem might be to avoid abrupt insertions but instead to proceed gradually, so as to allow the system to react and make way for the incoming particle. In this view of things, the 'occupation' of a certain atomic site can be viewed as a continuous variable, ranging between 0 and 1, representing 'how much' of the particle is present at any given time. These ideas proved ideal in Molecular Dynamics (MD) settings because equations of motions for these occupation variables can sometimes be obtained. For example, in the case of Grand Canonical Molecular Dynamics [Cagin91], one special particle is allowed to have a fractional occupation. This can lead to either its destruction (occupation = 0) or its complex creation (occupation = 1) so as to enforce a given chemical potential. These approaches proved useful, but mostly in the liquid state where the probability of successfully inserting a new particle is sufficiently high. At higher densities, convergence proved to be hampered by very inefficient sampling. In this work, we explore the use of a related MD-based grand canonical technique, the Grand Canonical Simulated Quenching (GCSQ) of Phillpot and Rickman [Phillpot92,Phillpot94], and explore its application to the grand canonical sampling of solid state systems. We show that, in conjunction with advanced sampling techniques, GCSQ can be a useful tool to sample conformations of complex systems, such as GBs, and assist in the identification of their most stable states and/or most likely defective states.

36 MATERIALS SCIENCE↗

Nevada National Security Site Integrated Groundwater Sampling Plan, Revision 0

The purpose of the Nevada National Security Site (NNSS) Integrated Sampling Plan (referred to herein as the Plan) is to provide a comprehensive, integrated approach for collecting and analyzing groundwater samples to meet the needs and objectives of the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) Underground Test Area (UGTA) Activity. Implementation of this Plan will provide high-quality data required by the UGTA Activity for ensuring public protection in an efficient and cost-effective manner. The Plan is designed to ensure compliance with the UGTA Quality Assurance Plan (QAP). The Plan’s scope comprises sample collection and analysis requirements relevant to assessing the extent of groundwater contamination from underground nuclear testing. This Plan identifies locations to be sampled by corrective action unit (CAU) and location type, sampling frequencies, sample collection methodologies, and the constituents to be analyzed. In addition, the Plan defines data collection criteria such as well-purging requirements, detection levels, and accuracy requirements; identifies reporting and data management requirements; and provides a process to ensure coordination between NNSS groundwater sampling programs for sampling of interest to UGTA. This Plan does not address compliance with requirements for wells that supply the NNSS public water system or wells involved in a permitted activity.

54 ENVIRONMENTAL SCIENCES↗

Data Validation Package, June 2016 Groundwater Sampling at the Hallam, Nebraska, Decommissioned Reactor Site, August 2016

The 2008 Long-Term Surveillance Plan [LTSP] for the Decommissioned Hallam Nuclear Power Facility, Hallam, Nebraska (http://www.lm.doe.gov/Hallam/Documents.aspx) requires groundwater monitoring once every 2 years. Seventeen monitoring wells at the Hallam site were sampled during this event as specified in the plan. Planned monitoring locations are shown in Attachment 1, Sampling and Analysis Work Order. Water levels were measured at all sampled wells and at two additional wells (6A and 6B) prior to the start of sampling. Additionally, water levels of each sampled well were measured at the beginning of sampling. See Attachment 2, Trip Report, for additional details. Sampling and analysis were conducted as specified in Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated, http://energy.gov/lm/downloads/sampling-and-analysis-plan-us-department- energy-office-legacy-management-sites). Gross alpha and gross beta are the only parameters that were detected at statistically significant concentrations. Time/concentration graphs of the gross alpha and gross beta data are included in Attachment 3, Data Presentation. The gross alpha and gross beta activity concentrations observed are consistent with values previously observed and are attributed to naturally occurring radionuclides (e.g., uranium and uranium decay chain products) in the groundwater.

2016 Groundwater Sampling↗

Data Validation Package - April and July 2015 Groundwater and Surface Water Sampling at the Gunnison, Colorado, Processing Site

This event included annual sampling of groundwater and surface water locations at the Gunnison, Colorado, Processing Site. Sampling and analyses were conducted as specified in Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites. Samples were collected from 28 monitoring wells, three domestic wells, and six surface locations in April at the processing site as specified in the 2010 Ground Water Compliance Action Plan for the Gunnison, Colorado, Processing Site. Domestic wells 0476 and 0477 were sampled in July because the homes were unoccupied in April, and the wells were not in use. Duplicate samples were collected from locations 0113, 0248, and 0477. One equipment blank was collected during this sampling event. Water levels were measured at all monitoring wells that were sampled. No issues were identified during the data validation process that requires additional action or follow-up.

54 ENVIRONMENTAL SCIENCES↗

Data Validation Package May 2016 Groundwater Sampling at the Lakeview, Oregon, Processing Site August 2016

This biennial event includes sampling five groundwater locations (four monitoring wells and one domestic well) at the Lakeview, Oregon, Processing Site. For this event, the domestic well (location 0543) could not be sampled because no one was in residence during the sampling event (Note: notification was provided to the resident prior to the event). Per Appendix A of the Groundwater Compliance Action Plan, sampling is conducted to monitor groundwater quality on a voluntary basis. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). One duplicate sample was collected from location 0505. Water levels were measured at each sampled monitoring well. The constituents monitored at the Lakeview site are manganese and sulfate. Monitoring locations that exceeded the U.S. Environmental Protection Agency (EPA) Secondary Maximum Contaminant Levels for these constituents are listed in Table 1. Review of time-concentration graphs included in this report indicate that manganese and sulfate concentrations are consistent with historical measurements.

2016 Groundwater Sampling Lakeview, Oregon↗

Data Validation Package December 2015 Groundwater Sampling at the Ambrosia Lake, New Mexico, Disposal Site March 2016

The Long-Term Surveillance Plan for the Ambrosia Lake, New Mexico, Disposal Site does not require groundwater monitoring because groundwater in the uppermost aquifer is of limited use, and supplemental standards have been applied to the aquifer. However, at the request of the New Mexico Environment Department, the U.S. Department of Energy conducts annual monitoring at three locations: monitoring wells 0409, 0675, and 0678. Sampling and analyses were conducted as specified in the Sampling and Analysis Plan for US. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). Monitoring Well 0409 was not sampled during this event because it was dry. Water levels were measured at each sampled well. One duplicate sample was collected from location 0675. Groundwater samples from the two sampled wells were analyzed for the constituents listed in Table 1. Time-concentration graphs for selected analytes are included in this report. At well 0675, the duplicate results for total dissolved solids and for most metals (magnesium, molybdenum, potassium, selenium, sodium, and uranium) were outside acceptance criteria, which may indicate non-homogeneous conditions at this location. November 2014 results for molybdenum and uranium at well 0675 also were outside acceptance criteria. The well condition will be evaluated prior to the next sampling event.

2015 Sampling Ambrosia Lake West, New Mexico↗

Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2009

Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory for the U.S. Department of Energy. Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 450.1 and DOE Order 5400.5. This document contains the calendar year 2009 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis. If a sample will not be collected in 2009, the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2009.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Soil Samplers: New Techniques for Subsurface Sampling for Volatile Organic Compounds

Soil sampling techniques for volatile organic analysis must be designed to minimize loss of volatile organic compounds (VOCs) from the soil that is being sampled. Preventing VOC loss from soil cores that are collected from the subsurface and brought to the surface for subsampling is often difficult. Subsurface bulk sample retrieval systems are designed to obtain intact cylindrical cores of soil ranging anywhere from one to four inches in diameter, and one to several feet in length. The current technique that is used to subsample these soil cores for VOC analysis is to expose a horizontal section of the soil core to the atmosphere; screen the exposed soil using a photoionization detector (PID) or other appropriate device to locate contamination in the soil core; and use a hand-operated coring tool to collect samples from the exposed soil for analysis. Because the soil core can be exposed to the atmosphere for a considerable length of time during screening and sample collection, the current sub-sampling technique provides opportunity for VOCs to be lost from the soil. This report describes three alternative techniques from the current technique for screening and collecting soil samples from subsurface soil cores for VOC analysis and field testing that has been done to evaluate the techniques. Based on the results of the field testing, ASTM D4547, Standard Guide for Sampling Waste and Soils for Volatile Organic Compounds, was revised to include information about the new techniques.

54 ENVIRONMENTAL SCIENCES↗

Graph Sampling for Visual Analytics

Effectively visualizing large graphs and capturing the statistical properties are two challenging tasks. To aid in these two tasks, many sampling approaches for graph simplification have been proposed, falling into three categories: node sampling, edge sampling, and traversal-based sampling. It is still unknown which approach is the best. We evaluate commonly used graph sampling methods through a combined visual and statistical comparison of graphs sampled at various rates. We conduct our evaluation on three graph models: random graphs, small-world graphs, and scale-free graphs. Initial results indicate that the effectiveness of a sampling method is dependent on the graph model, the size of the graph, and the desired statistical property. This benchmark study can be used as a guideline in choosing the appropriate method for a particular graph sampling task, and the results presented can be incorporated into graph visualization and analysis tools.

97 MATHEMATICS AND COMPUTING↗

Ultra-Fast Sample Preparation for High-Throughput Proteomics

Sample preparation oftentimes can be the Achilles Heel of any analytical process and in the field of proteomics, preparing samples for mass spectrometric analysis is no exception. Current goals, concerning proteomic sample preparation on a large scale, include efforts toward improving reproducibility, reducing the time of processing and ultimately the automation of the entire workflow. This chapter reviews an array of recent approaches applied to bottom-up proteomics sample preparation to reduce the processing time down from hours to minutes. The current state-of-the-art in the field uses different energy inputs like microwave, ultrasound or pressure to perform the four basic steps in sample preparation: protein extraction, denaturation, reduction and alkylation, and digestion. No single energy input for enhancement of proteome sample preparation has become the universal gold standard. Instead, a combination of different energy inputs tend to produce the best results. This chapter further describes the future trends in the field such as the hyphenation of sample preparation with downstream detection and analysis systems. Finally, a detailed protocol describing the combined use of both pressure cycling technology and ultrasonic energy inputs to hasten proteomic sample preparation is presented.

59 BASIC BIOLOGICAL SCIENCES↗

Microfluidic-Based Robotic Sampling System for Radioactive Solutions

A novel microfluidic based robotic sampling system has been developed for sampling and analysis of liquid solutions in nuclear processes. This system couples the use of a microfluidic sample chip with a robotic system designed to allow remote, automated sampling of process solutions in-cell and facilitates direct coupling of the microfluidic sample chip with analytical instrumentation. This system provides the capability for near real time analysis, reduces analytical waste, and minimizes the potential for personnel exposure associated with traditional sampling methods. A prototype sampling system was designed, built and tested. System testing demonstrated operability of the microfluidic based sample system and identified system modifications to optimize performance.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Towards a Robust Sampling Approach: A Computational Review and Design

As pointed out in several other works, the estimation of the reliability of the electrical grid can not be conducted without the estimation of the stochastic phenomena of electicity demand and electricity production by variable renewable sources. Therefore, sampling procedures have become integral in the design of engineering structures and analysis. Commonly referred to as Monte Carlo uncertainty analysis or integration, the general objective of these procedures is to establish specifics about the uncertainty of an output characteristic of such an engineering system, given uncertainty about its input characteristics. These sampling procedures are applied in a context in which establishing such specifics cannot be performed through other means. Variance-reduction techniques are designed to lessen the variability among estimators to estimate statistics of those output uncertainties. Importance-sampling techniques, on the other hand, are designed to reduce the number of samples needed to estimate a particular statistic—e.g., a tail probability. The combination of these approaches can reduce the computational burden considerably for a particular estimator and statistic. Importance sampling—geared and designed as it is toward improving a particular estimator—suffers, unfortunately, from the unintended consequence of reducing the performance of other estimators in terms of their variance. The objective of this paper is to offer an alternative sampling procedure where this variance does not grow unacceptably large for a suite of estimators. Moreover, it is anticipated that, with additional knowledge of how an engineering output characteristic responds to its input characteristics, tuning parameters of the input’s sampling procedure can be set to improve the output characteristic’s estimation. This work proves the effectiveness of the suggested alternative approach. Such positive outcome will lead to a decrease of the computational burden of performing stochastic optimization of integrated energy systems (e.g., components dispatch, and portfolio composition). In particular, capturing the contribution to the overall system cost of rare and unlikely events and patterns of the electricity demand and production will become less computationally expensive. This is due to the fact that the approach demonstrated here will allow the sampling of those rare occurrences more frequently without misrepresenting their probabilistic impacts.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Expediting Groundwater Sampling at Hanford and Making It Safer - 13158

The CH2M HILL Plateau Remediation Company (CHPRC) manages the groundwater monitoring programs at the Department of Energy's 586-square-mile Hanford site in southeastern Washington state. These programs are regulated by the Resource Conservation and Recovery Act (RCRA), the Comprehensive Environmental Response Compensation and Liability Act (CERCLA), and the Atomic Energy Act (AEA). The purpose of monitoring is to track existing groundwater contamination from past practices, as well as other potential contamination that might originate from RCRA treatment, storage, and disposal (TSD) facilities. An integral part of the groundwater-monitoring program involves taking samples of the groundwater and measuring the water levels in wells scattered across the site. Each year, more than 1,500 wells are accessed for a variety of reasons. Historically, the monitoring activities have been very 'people intensive'. Field personnel or 'samplers' have been issued pre-printed forms showing information about the well(s) for a particular sampling evolution. This information is taken from two official electronic databases: the Hanford Well Information System (HWIS) and the Hanford Environmental Information System (HEIS). The samplers traditionally used these hardcopy forms to document the groundwater samples and well water-levels. After recording the entries in the field, the samplers turned the forms in at the end of the day and other personnel posted the collected information. In Automating Groundwater Sampling at Hanford (HNF-38542-FP Revision 0, Presented at Waste Management 2009 Conference, March 1 - March 5, 2009, Phoenix, AZ), we described the methods, tools, and techniques that would be used in automating the activities associated with measuring water levels. The Field Logging and Electronic Data Gathering (FLEDG) application/database that automates collecting the water-level measurement data has now been implemented at Hanford. In addition to eliminating the need to print out documents, the system saves three-to-four man days each month for the field personnel taking the measurements and the scientists and administrators managing the data and the documentation. After the information has received technical review, FLEDG automatically updates the database for water-level measurements and loads the document management system with the completed sampling report. Due to safety considerations, access to wells is conditional. A spreadsheet with appropriate data not only lists the wells that are cleared for work, but also the safety personnel who must be present before work can start. This spreadsheet is used in planning daily activities. Daily plans are structured to ensure that the wells to be sampled are cleared for work and the appropriate safety personnel have been assigned and are present before the work starts. Historically, the spreadsheets have been prepared manually, and as a result, are potentially subject to human error. However, a companion database application has been developed to work with FLEDG - making the entire sampling process more efficient and safer for personnel. The Well Access List - Electronic, WAL-E, is a database that contains much the same information that was previously manually loaded into the spread sheet. In addition, WAL-E contains a managed work-flow application that shows the access requirements and allows for appropriate reviews of the compiled well. Various CHPRC organizations, including Industrial Hygiene, RADCON, and Well Maintenance and Sample Administration are able to enter and review the wells added or deleted from the WAL-E database. The FLEDG system then accesses this database information to identify appropriate support personnel and provide safety requirements to field personnel. In addition, WAL-E offers the assurance that wells have appropriate locks and are correctly labeled and electrically grounded as required, before well activities begin. This feature is an extremely important aspect of the FLEDG/WAL-E system because it adds another safety check to the work evolution and reduces the potential for unsafe conditions to exist that would lead to a stop-work situation. This paper will further describe the technical aspects of both electronic programs/databases and their successful application at Hanford. (authors)

54 ENVIRONMENTAL SCIENCES↗

Small Scale Mixing Demonstration Batch Transfer and Sampling Performance of Simulated HLW - 12307

The ability to effectively mix, sample, certify, and deliver consistent batches of High Level Waste (HLW) feed from the Hanford Double Shell Tanks (DST) to the Waste treatment Plant (WTP) has been recognized as a significant mission risk with potential to impact mission length and the quantity of HLW glass produced. At the end of 2009 DOE's Tank Operations Contractor, Washington River Protection Solutions (WRPS), awarded a contract to EnergySolutions to design, fabricate and operate a demonstration platform called the Small Scale Mixing Demonstration (SSMD) to establish pre-transfer sampling capacity, and batch transfer performance data at two different scales. This data will be used to examine the baseline capacity for a tank mixed via rotational jet mixers to transfer consistent or bounding batches, and provide scale up information to predict full scale operational performance. This information will then in turn be used to define the baseline capacity of such a system to transfer and sample batches sent to WTP. The Small Scale Mixing Demonstration (SSMD) platform consists of 43'' and 120'' diameter clear acrylic test vessels, each equipped with two scaled jet mixer pump assemblies, and all supporting vessels, controls, services, and simulant make up facilities. All tank internals have been modeled including the air lift circulators (ALCs), the steam heating coil, and the radius between the wall and floor. The test vessels are set up to simulate the transfer of HLW out of a mixed tank, and collect a pre-transfer sample in a manner similar to the proposed baseline configuration. The collected material is submitted to an NQA-1 laboratory for chemical analysis. Previous work has been done to assess tank mixing performance at both scales. This work involved a combination of unique instruments to understand the three dimensional distribution of solids using a combination of Coriolis meter measurements, in situ chord length distribution measurements, and electro-resistive tomography. This current work utilized the same instruments to monitor simulated waste transfers. This paper will discuss some of the scaling compromises when it came to the scaled sampling system design, handling of large quantities of material for sampling, and present data for the discuss of likely behavior of the full scale DST based on scaling correlations using a scale ratio exponent (SRE) from 0.25 to 0.45 and the behavior observed in the SSMD platform. This does not establish a scaling factor for DST mixing using paired jet mixers but is an attempt to envelope the likely performance ranges in terms of certification sampling bias, certification sample root-mean-square-deviation, and bath to batch relative standard deviation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Delayed-Gamma Energy Biasing with Exact Energy Sampling in MCNP 6.2.0

Characterization of delayed-particle signatures is of the utmost importance for detecting, identifying, and quantifying special nuclear material (SNM). Various non-destructive assay (NDA) techniques used in nuclear material safeguards rely on characteristic gamma-ray or neutron emissions to infer properties of a material. The all-particle, all-energy Monte-Carlo radiation transport code MCNP6 is capable of simulating delayed-particle signatures from SNM in addition to modeling the transport of emitted particles to a detector or other instrument. In some cases, NDA techniques require the measurement of low probability emissions from a given material. In physical scenarios, this problem can be bypassed by longer count-times or may be simply irrelevant due to the mass, and therefore the total activity, of the material being measured. However, when applying the Monte-Carlo method to such scenarios, sampling of low probability emissions requires a large number of histories to converge to a statistically acceptable solution. To address this issue, the delayed-neutron and gamma energy biasing feature was introduced in MCNP6 by H. Armstrong et al. in 2013 which allows the user to set up energy windows in which delayed-particle emission sampling can be adjusted. For delayed-gamma sampling, this biasing method was based on the bin-wise structure of gamma emission data for both the multi-bin gamma and line-emission sampling modes. Recent improvements have been made to the line-emission sampling algorithm which upgrade the previous mini-bin sampling treatment to an exact energy-line treatment. This upgrade was not compatible with the biasing method implemented by H. Armstrong et al. due to the sampled data no longer having a bin-wise structure in line-emission mode. For this reason the delayed-gamma energy biasing feature has been rewritten to support the exact line-sampling treatment. This paper provides a description of the delayed-gamma energy biasing (DGEB) feature in MCNP6 as well as results and discussion for a gamma-ray spectroscopy example used to demonstrate the biasing utility. (authors)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗