Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Direct analysis of cotton swipes for uranium and plutonium isotopic determination by microextraction-ICP-MS

The determination of uranium and plutonium isotopic abundance on environmental samples collected by International Atomic Energy Agency (IAEA) inspectors is vital for the detection of undeclared nuclear activities and material under the international nuclear safeguards regime. Current analytical protocols require time-consuming sample preparation steps prior to subsequent measurement by inorganic mass spectrometry (MS). Recent efforts from this laboratory have focused on developing sample preparation methods for faster analysis, potentially allowing higher sample throughput[1]. Alternative methods including microextraction sampling in conjunction with inductively coupled plasma-mass spectrometry (ICP-MS) have been recently explored. This methodology, microextraction-ICP-MS, was developed such that uranium and plutonium could be extracted from the swipe surface and directed into the ICP-MS for an in-situ measurement, eliminating the need for swipe ashing and digestion. A commercial off-the-shelf microextraction system was customized with an automated movable XY stage that can be programmed to save sampling locations, allowing for automated rapid sampling of swipe surfaces. Additional efforts have focused on the utilization of collision cell technology to the microextraction ICP-MS method. This would eliminate the need for lengthy column chemistry procedures to purify separated uranium and plutonium fractions before analysis. Here, the extracted U/Pu analyte is measured by reacting the uranium ions with CO2 in the collision cell of an ICP-MS, shifting the uranium to UO+, which will not interfere with the plutonium isotopic determination. The developed method utilizing collision cell – ICP-MS technology has demonstrated the ability to measure plutonium isotope ratios in the presence of high uranium concentration on the transient signal from the microextraction system utilizing certified reference materials from JRC-Geel and the New Brunswick Laboratory Program Office.

Bradley, Veronica↗

INVESTIGATION OF THE TOTAL ORGANIC HALOGEN ANALYTICAL METHOD AT THE WASTE SAMPLING CHARACTERIZATION FACILITY (WSCF)

Total organic halogen (TOX) is used as a parameter to screen groundwater samples at the Hanford Site. Trending is done for each groundwater well, and changes in TOX and other screening parameters can lead to costly changes in the monitoring protocol. The Waste Sampling and Characterization Facility (WSCF) analyzes groundwater samples for TOX using the United States Environmental Protection Agency (EPA) SW-846 method 9020B (EPA 1996a). Samples from the Soil and Groundwater Remediation Project (S&GRP) are submitted to the WSCF for analysis without information regarding the source of the sample; each sample is in essence a 'blind' sample to the laboratory. Feedback from the S&GRP indicated that some of the WSCF-generated TOX data from groundwater wells had a number of outlier values based on the historical trends (Anastos 2008a). Additionally, analysts at WSCF observed inconsistent TOX results among field sample replicates. Therefore, the WSCF lab performed an investigation of the TOX analysis to determine the cause of the outlier data points. Two causes were found that contributed to generating out-of-trend TOX data: (1) The presence of inorganic chloride in the groundwater samples: at inorganic chloride concentrations greater than about 10 parts per million (ppm), apparent TOX values increase with increasing chloride concentration. A parallel observation is the increase in apparent breakthrough of TOX from the first to the second activated-carbon adsorption tubes with increasing inorganic chloride concentration. (2) During the sample preparation step, excessive purging of the adsorption tubes with oxygen pressurization gas after sample loading may cause channeling in the activated-carbon bed. This channeling leads to poor removal of inorganic chloride during the subsequent wash step with aqueous potassium nitrate. The presence of this residual inorganic chloride then produces erroneously high TOX values. Changes in sample preparation were studied to more effectively remove inorganic chloride from the activated carbon adsorption tubes. With the TOX sample preparation equipment and TOX analyzers at WSCF, the nitrate wash recommended by EPA SW-846 method 9020B was found to be inadequate to remove inorganic chloride interference. Increasing the nitrate wash concentration from 10 grams per liter (g/L) to 100 g/L potassium nitrate and increasing the nitrate wash volume from 3 milliliters (mL) to 10 mL effectively removed the inorganic chloride up to at least 100 ppm chloride in the sample matrix. Excessive purging of the adsorption tubes during sample preparation was eliminated. These changes in sample preparation have been incorporated in the analytical procedure. The results using the revised sample preparation procedure show better agreement of TOX values both for replicate analyses of single samples and for the analysis of replicate samples acquired from the same groundwater well. Furthermore, less apparent column breakthrough now occurs with the revised procedure. One additional modification made to sample preparation was to discontinue the treatment of groundwater samples with sodium bisulfite. Sodium bisulfite is used to remove inorganic chlorine from the sample; inorganic chlorine is not expected to be a constituent in these groundwater samples. Several other factors were also investigated as possible sources of anomalous TOX results: (1) Instrument instability: examination of the history of results for TOX laboratory control samples and initial calibration verification standards indicate good long-term precision for the method and instrument. Determination of a method detection limit of 2.3 ppb in a deionized water matrix indicates the method and instrumentation have good stability and repeatability. (2) Non-linear instrument response: the instrument is shown to have good linear response from zero to 200 parts per billion (ppb) TOX. This concentration range encompasses the majority of samples received at WSCF for TOX analysis. (3) Improper sample preservation: ion-chromatographic analysis of several samples with anomalous TOX results revealed that the samples were properly preserved with sulfuric acid and not hydrochloric acid.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Uncertainties in Air Exchange using Continuous-Injection, Long-Term Sampling Tracer-Gas Methods

The PerFluorocarbon Tracer (PFT) method is a low-cost approach commonly used for measuring air exchange in buildings using tracer gases. It is a specific application of the more general Continuous-Injection, Long-Term Sampling (CILTS) method. The technique is widely used but there has been little work on understanding the uncertainties (both precision and bias) associated with its use, particularly given that it is typically deployed by untrained or lightly trained people to minimize experimental costs. In this article we will conduct a first-principles error analysis to estimate the uncertainties and then compare that analysis to CILTS measurements that were over-sampled, through the use of multiple tracers and emitter and sampler distribution patterns, in three houses. We find that the CILTS method can have an overall uncertainty of 10-15percent in ideal circumstances, but that even in highly controlled field experiments done by trained experimenters expected uncertainties are about 20percent. In addition, there are many field conditions (such as open windows) where CILTS is not likely to provide any quantitative data. Even avoiding the worst situations of assumption violations CILTS should be considered as having a something like a ?factor of two? uncertainty for the broad field trials that it is typically used in. We provide guidance on how to deploy CILTS and design the experiment to minimize uncertainties.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Systems and methods for laser assisted sample transfer to solution for chemical analysis

Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Systems and methods for laser assisted sample transfer to solution for chemical analysis

Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Systems and methods for laser assisted sample transfer to solution for chemical analysis

Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

47 OTHER INSTRUMENTATION↗

INVESTIGATION OF THE TOTAL ORGANIC HALOGEN ANALYTICAL METHOD AT THE WASTE SAMPLING AND CHARACTERIZATION FACILITY

Total organic halogen (TOX) is used as a parameter to screen groundwater samples at the Hanford Site. Trending is done for each groundwater well, and changes in TOX and other screening parameters can lead to costly changes in the monitoring protocol. The Waste Sampling and Characterization Facility (WSCF) analyzes groundwater samples for TOX using the United States Environmental Protection Agency (EPA) SW-S46 method 9020B (EPA 1996a). Samples from the Soil and Groundwater Remediation Project (SGRP) are submitted to the WSCF for analysis without information regarding the source of the sample; each sample is in essence a ''blind'' sample to the laboratory. Feedback from the SGRP indicated that some of the WSCF-generated TOX data from groundwater wells had a number of outlier values based on the historical trends (Anastos 200Sa). Additionally, analysts at WSCF observed inconsistent TOX results among field sample replicates. Therefore, the WSCF lab performed an investigation of the TOX analysis to determine the cause of the outlier data points. Two causes were found that contributed to generating out-of-trend TOX data: (1) The presence of inorganic chloride in the groundwater samples: at inorganic chloride concentrations greater than about 10 parts per million (ppm), apparent TOX values increase with increasing chloride concentration. A parallel observation is the increase in apparent breakthrough of TOX from the first to the second activated-carbon adsorption tubes with increasing inorganic chloride concentration. (2) During the sample preparation step, excessive purging of the adsorption tubes with oxygen pressurization gas after sample loading may cause channeling in the activated carbon bed. This channeling leads to poor removal of inorganic chloride during the subsequent wash step with aqueous potassium nitrate. The presence of this residual inorganic chloride then produces erroneously high TOX values. Changes in sample preparation were studied to more effectively remove inorganic chloride from the activated-carbon adsorption tubes. With the TOX sample preparation equipment and TOX analyzers at WSCF, the nitrate wash recommended by EPA SW-846 method 9020B was found to be inadequate to remove inorganic chloride interference. Increasing the nitrate wash concentration from 10 grams per liter (g/L) to 100 giL potassium nitrate and increasing the nitrate wash volume from 3 milliliters (mL) to 10 mL effectively removed the inorganic chloride up to at least 100 ppm chloride in the sample matrix. Excessive purging of the adsorption tubes during sample preparation was eliminated. These changes in sample preparation have been incorporated in the analytical procedure. The results using the revised sample preparation procedure show better agreement of TOX values both for replicate analyses of single samples and for the analysis of replicate samples acquired from the same groundwater well. Furthermore, less apparent adsorption tube breakthrough now occurs with the revised procedure. One additional modification made to sample preparation was to discontinue the treatment of groundwater samples with sodium bisulfite. Sodium bisulfite is used to remove inorganic chlorine from the sample; inorganic chlorine is not expected to be a constituent in these groundwater samples. Several other factors were also investigated as possible sources of anomalous TOX results: (1) Instrument instability: examination of the history of results for TOX laboratory control samples and initial calibration verification standards indicate good long-term precision for the method and instrument. Determination of a method detection limit of 2.3 ppb in a deionized water matrix indicates the method and instrumentation have good stability and repeatability. (2) Non-linear instrument response: the instrument is shown to have good linear response from zero to 200 parts per billion (ppb) TOX. This concentration range encompasses the majority of samples received at WSCF for TOX analysis. Linear response was checked using both non-volatile TOX species (trichlorophenol) and volatile TOX species. Average recoveries of the volatile TOX species ranged between 50% and 75%. (3) Improper sample preservation: ion-chromatographic analysis of several samples with anomalous TOX results revealed that the samples were properly preserved with sulfuric acid and not hydrochloric acid.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High efficiency active environmental sampling of chemical traces

A method of sample collection includes collecting an analyte from a sampling surface using a rapidly curable liquid gel comprising one or more metal particles; co-aggregating the one or more metal particles from the rapidly curable liquid gel and the analyte from the sampling surface; and rapidly curing the rapidly curable liquid gel. The composition and sample preparation conditions may facilitate improved collection efficiency of analytes during environmental and forensic evidence sampling. In addition, the composition and sample preparation conditions may facilitate enhanced detection and identification of the analyte using e.g., Surface Enhanced Raman Spectrometry (SERS).

Junghans, Ann↗

Influence of sampling frequency and estimation method on phosphorus load uncertainty in the Western Lake Erie Basin, Ohio, USA

Accurate estimates of nutrient loads are necessary to identify critical source areas and quantify the impact of management practices on pollutant export. Previous studies have investigated nutrient load estimate uncertainty, but they often focus on nutrient loads estimated using an interpolation method for large-scale watersheds with short-term datasets. The study objective was to quantify uncertainty in soluble reactive phosphorus (SRP), total phosphorus (TP), and suspended solids (SS) load estimates from two small (<10 3 km 2 ) agricultural watersheds in the western Lake Erie Basin resulting from different sampling frequencies. Each watershed had high temporal resolution datasets of discharge (15 min) and nutrient concentration (1 to 3 samples per day) collected over a 30-year period (1990–2020). Firstly, SRP, TP, and SS loads were calculated using the high temporal resolution datasets, which was assumed as “true loads”. Secondly, the high temporal concentration data were decomposed to semiweekly, weekly, biweekly, and monthly sampling and annual loads were estimated using four common load estimation methods to assess the effect of sampling frequency and load estimation method on load estimate error. Across the four different methods, the composite method had the lowest relative root mean square and absolute bias, but the rectangular interpolation method was the most precise. Furthermore, even with semiweekly sampling, the composite method resulted in an unacceptable level of precision (average imprecision = 39 %), while the interpolation method resulted in an unacceptable bias (average absolute bias = 16 %). Because neither method could provide acceptable accuracy and precision at the lowest decrease in sampling (e.t. semiweekly sampling), continued daily sampling is recommended in these watersheds.

54 ENVIRONMENTAL SCIENCES↗

Room temperature ferromagnetism and luminescent behavior of Ni doped ZnO nanoparticles prepared by coprecipitation method

The samples of Zn{sub 1-x}Ni{sub x}O (x= 0.00 and 0.05) were prepared using coprecipitation method and annealed at different temperatures. The effect of Ni ion substitution on the structural and optical properties has been studied using X-ray Diffraction, UV-Visible, Photoluminescence and Magnetic measurements. XRD measurements demonstrate that all the prepared samples are wurtzite polycrystalline single phase in nature, ruling out the presence of any secondary phase formation. Ultraviolet visible measurements showed a decrease in band gap with the increase in annealing temperature and doping concentration. The PL data shows the red shift in all the samples and luminescence quenching with Ni doping. Compared to undoped ZnO, Ni doped ZnO showed room temperature ferromagnetism.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

System and method for laser assisted sample transfer to solution for chemical analysis

A system and method for laser desorption of an analyte from a specimen and capturing of the analyte in a suspended solvent to form a testing solution are described. The method can include providing a specimen supported by a desorption region of a specimen stage and desorbing an analyte from a target site of the specimen with a laser beam centered at a radiation wavelength (.lamda.). The desorption region is transparent to the radiation wavelength (.lamda.) and the sampling probe and a laser source emitting the laser beam are on opposite sides of a primary surface of the specimen stage. The system can also be arranged where the laser source and the sampling probe are on the same side of a primary surface of the specimen stage. The testing solution can then be analyzed using an analytical instrument or undergo further processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Comparison of the FW-CADIS and MR-CADIS Variance Reduction Methods

The Consistent Adjoint Driven Importance Sampling (CADIS) method, which uses an adjoint deterministic estimate for making variance reduction parameters that optimize Monte Carlo (MC) shielding calculations, was introduced in 1998. This method was designed to optimize a single tally, typically an integrated response such as a detector count rate or a dose rate. Because both deterministic and stochastic methods are employed, CADIS is referred to as a hybrid method. In 2007, the forward-weighted CADIS (FW-CADIS) method was introduced to optimize several tallies at once, giving more uniform relative uncertainties among the tallies for both high-flux and low-flux areas of the problem. This method can be used for several small detectors, for semi-global problems (mesh tally over a large fraction of the problem), or for global problems (mesh tally over the entire problem). Optimization can be done for an integrated response such as a dose rate D(r) as a function of position, the total flux {phi}(r) as a function of position, or the space/energy flux {phi}(r,E). Both the CADIS and FW-CADIS methods have been in the MAVRIC sequence of SCALE for three versions (6.0 in 2009, 6.1 in 2011, and 6.2 in 2016). The ADVANTG package released in 2015 uses the CADIS and FW-CADIS methods to accelerate MCNP neutron/photon shielding calculations. In 2014, the multi-response CADIS (MR-CADIS) method was presented as a way to obtain even more uniform relative uncertainties for problems with multiple tallies than those obtained with FW-CADIS. The method does not use a forward deterministic calculation but instead uses one adjoint calculation for every tally to be optimized in the Monte Carlo calculation. This work compares the above methods.

42 ENGINEERING↗

Temperature Dependent Raman Spectroscopic Study of the Fe Doped La{sub 0.67}Sr{sub 0.33}MnO{sub 3} Prepared Using Ball Milling Method

Polycrystalline samples of La{sub 0.67}Sr{sub 0.33}Mn{sub 0.65}Fe{sub 0.35}O{sub 3} (LSMFO) were synthesized using the standard ball mill method with different calcination temperatures ranging from 800 to 1100°C for 7 h. The phase purity of these samples was confirmed using X-ray diffraction (XRD) patterns. All samples were found to have rhombohedral crystal structure with R 3-bar c space group. The lattice parameters, cell volume, bond angle and bond length have been obtained using the Rietveld refinement by FullProf software. The average crystallite size calculated using the Debye-Scherrer formula was found between 27 and 60 nm. Surface morphology of the prepared samples has been examined using a scanning electron microscope (SEM). SEM images show the formation of well-arranged grain sizes distributed from 240 to 400 nm, much larger than one estimated using the Scherrer formula. All tiny particles are highly agglomerated with the increasing temperature and porosity decreases with increasing temperature. An analysis of the frequency and peak broadening of Raman modes as a function of temperature clearly shows the significant temperature effect on the A{sub 1g} and E{sub g} modes of LSMFO. The shifts and broadening of the A{sub 1g} and E{sub g} modes are discussed in light of the oxygen sublattice distortion. Our study shows the reduction in distortion with increasing calcination temperature, which suggests a decrease in the JT effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Predicting Ice Sheet and Climate Evolution at Extreme Scales

A main research objectives of PISCEES is the development of formal methods for quantifying uncertainties in ice sheet modeling. Uncertainties in simulating and projecting mass loss from the polar ice sheets arise primarily from initial conditions, surface and basal boundary conditions, and model parameters. In general terms, two main chains of uncertainty propagation may be identified: 1. inverse propagation of observation and/or prior onto posterior control variable uncertainties; 2. forward propagation of prior or posterior control variable uncertainties onto those of target output quantities of interest (e.g., climate indices or ice sheet mass loss). A related goal is the development of computationally efficient methods for producing initial conditions for an ice sheet that are close to available present-day observations and essentially free of artificial model drift, which is required in order to be useful for model projections (“initialization problem”). To be of maximum value, such optimal initial states should be accompanied by “useful” uncertainty estimates that account for the different sources of uncerainties, as well as the degree to which the optimum state is constrained by available observations. The PISCEES proposal outlined two approaches for quantifying uncertainties. The first targets the full exploration of the uncertainty in model projections with sampling-based methods and a workflow managed by DAKOTA (the main delivery vehicle for software developed under QUEST). This is feasible for low-dimensional problems, e.g., those with a handful of global parameters to be inferred. This approach can benefit from derivative/adjoint information, but it is not necessary, which is why it often referred to as “non-intrusive”. The second approach makes heavy use of derivative information from model adjoints to address quantifying uncertainty in high-dimensions (e.g., basal boundary conditions in ice sheet models). The use of local gradient, or Hessian information (i.e., second derivatives of the cost function), requires additional code development and implementation, and is thus often referred to as an “intrusive” approach. Within PISCEES, MIT has been tasked to develop methods for derivative-based UQ, the ”intrusive” approach discussed above. These methods rely on the availability of first (adjoint) and second (Hessian) derivative code, developed through intrusive methods such as algorithmic differentiation (AD). While representing a significant burden in terms of code development, derivative-baesd UQ is able to cope with very high-dimensional uncertainty spaces. That is, unlike sampling methods (all variations of Monte Carlo), calculational burden is independent of the dimension of the uncertainty space. This is a significant advantage for spatially distributed uncertainty fields, such as threedimensional initial conditions, three-dimensional parameter fields, or two-dimensional surface and basal boundary conditions. Importantly, uncertainty fields for ice sheet models generally fall into this category.

97 MATHEMATICS AND COMPUTING↗

A novel analysis method for paired-sample microbial ecology experiments

Many microbial ecology experiments use sequencing data to measure a community s response to an experimental treatment. In a common experimental design, two units, one control and one experimental, are sampled before and after the treatment is applied to the experimental unit. The four resulting samples contain information about the dynamics of organisms that respond to the treatment, but there are no analytical methods designed to extract exactly this type of information from this configuration of samples. Here we present an analytical method specifically designed to visualize and generate hypotheses about microbial community dynamics in experiments that have paired samples and few or no replicates. The method is based on the Poisson lognormal distribution, long studied in macroecology, which we found accurately models the abundance distribution of taxa counts from 16S rRNA surveys. To demonstrate the method s validity and potential, we analyzed an experiment that measured the effect of crude oil on ocean microbial communities in microcosm. Our method identified known oil degraders as well as two clades, Maricurvus and Rhodobacteraceae, that responded to amendment with oil but do not include known oil degraders. Furthermore, our approach is sensitive to organisms that increased in abundance only in the experimental unit but less sensitive to organisms that increased in both control and experimental units, thus mitigating the role of bottle effects .

59 BASIC BIOLOGICAL SCIENCES↗

The Fifth International Workshop on Ice Nucleation phase 2 (FIN-02): laboratory intercomparison of ice nucleation measurements

Abstract. The second phase of the Fifth International Ice Nucleation Workshop (FIN-02)involved the gathering of a large number of researchers at the KarlsruheInstitute of Technology's Aerosol Interactions and Dynamics of the Atmosphere(AIDA) facility to promote characterization and understanding of icenucleation measurements made by a variety of methods used worldwide.Compared to the previous workshop in 2007, participation was doubled,reflecting a vibrant research area. Experimental methods involved sampling ofaerosol particles by direct processing ice nucleation measuring systems fromthe same volume of air in separate experiments using different ice nucleatingparticle (INP) types, and collections of aerosol particle samples ontofilters or into liquid for sharing amongst measurement techniques thatpost-process these samples. In this manner, any errors introduced bydifferences in generation methods when samples are shared across laboratorieswere mitigated. Furthermore, as much as possible, aerosol particle sizedistribution was controlled so that the size limitations of different methodswere minimized. The results presented here use data from the workshop toassess the comparability of immersion freezing measurement methods activatingINPs in bulk suspensions, methods that activate INPs in condensation and/orimmersion freezing modes as single particles on a substrate, continuous flowdiffusion chambers (CFDCs) directly sampling and processing particles wellabove water saturation to maximize immersion and subsequent freezing ofaerosol particles, and expansion cloud chamber simulations in which liquidcloud droplets were first activated on aerosol particles prior to freezing.The AIDA expansion chamber measurements are expected to be the closestrepresentation to INP activation in atmospheric cloud parcels in thesecomparisons, due to exposing particles freely to adiabatic cooling. The different particle types used as INPs included the minerals illite NX andpotassium feldspar (K-feldspar), two natural soil dusts representative of arable sandy loam(Argentina) and highly erodible sandy dryland (Tunisia) soils, respectively,and a bacterial INP (Snomax ® ). Consideredtogether, the agreement among post-processed immersion freezing measurementsof the numbers and fractions of particles active at different temperaturesfollowing bulk collection of particles into liquid was excellent, withpossible temperature uncertainties inferred to be a key factor in determiningINP uncertainties. Collection onto filters for rinsing versus directly intoliquid in impingers made little difference. For methods that activatedcollected single particles on a substrate at a controlled humidity at orabove water saturation, agreement with immersion freezing methods was good inmost cases, but was biased low in a few others for reasons that have not beenresolved, but could relate to water vapor competition effects. AmongstCFDC-style instruments, various factors requiring (variable) highersupersaturations to achieve equivalent immersion freezing activation dominatethe uncertainty between these measurements, and for comparison with bulkimmersion freezing methods. When operated above water saturation to includeassessment of immersion freezing, CFDC measurements often measured at orabove the upper bound of immersion freezing device measurements, but oftenunderestimated INP concentration in comparison to an immersion freezingmethod that first activates all particles into liquid droplets prior tocooling (the PIMCA-PINC device, or Portable Immersion Mode Cooling chAmber–Portable Ice Nucleation Chamber), and typically slightly underestimated INPnumber concentrations in comparison to cloud parcel expansions in the AIDAchamber; this can be largely mitigated when it is possible to raise therelative humidity to sufficiently high values in the CFDCs, although this isnot always possible operationally. Correspondence of measurements of INPs among direct sampling andpost-processing systems varied depending on the INP type. Agreement was bestfor Snomax ® particles in the temperature regimecolder than −10 ∘ C, where their ice nucleation activity is nearlymaximized and changes very little with temperature. At temperatures warmer than −10 ∘ C, Snomax ® INP measurements (allvia freezing of suspensions) demonstrated discrepancies consistent withprevious reports of the instability of its protein aggregates that appear tomake it less suitable as a calibration INP at these temperatures. ForArgentinian soil dust particles, there was excellent agreement across allmeasurement methods; measures ranged within 1 order of magnitude for INPnumber concentrations, active fractions and calculated active site densitiesover a 25 to 30 ∘ C range and 5 to 8 orders of correspondingmagnitude change in number concentrations. This was also the case for alltemperatures warmer than −25 ∘ C in Tunisian dust experiments. Incontrast, discrepancies in measurements of INP concentrations or active sitedensities that exceeded 2 orders of magnitude across a broad range of temperaturemeasurements found at temperatures warmer than −25 ∘ C in a previous study werereplicated for illite NX. Discrepancies also exceeded 2 orders of magnitude attemperatures of −20 to −25 ∘ C for potassium feldspar (K-feldspar), but these coincidedwith the range of temperatures at which INP concentrations increase rapidly atapproximately an order of magnitude per 2 ∘ C cooling forK-feldspar. These few discrepancies did not outweigh the overall positive outcomes of theworkshop activity, nor the future utility of this data set or future similarefforts for resolving remaining measurement issues. Measurements of the samematerials were repeatable over the time of the workshop and demonstratedstrong consistency with prior studies, as reflected by agreement of databroadly with parameterizations of different specific or general (e.g., soildust) aerosol types. The divergent measurements of the INP activity of illiteNX by direct versus post-processing methods were not repeated for otherparticle types, and the Snomax ® datademonstrated that, at least for a biological INP type, there is no expectedmeasurement bias between bulk collection and direct immediately processedfreezing methods to as warm as −10 ∘ C. Since particle size rangeswere limited for this workshop, it can be expected that for atmosphericpopulations of INPs, measurement discrepancies will appear due to thedifferent capabilities of methods for sampling the full aerosol sizedistribution, or due to limitations on achieving sufficient watersupersaturations to fully capture immersion freezing in direct processinginstruments. Overall, this workshop presents an improved picture of presentcapabilities for measuring INPs than in past workshops, and providesdirection toward addressing remaining measurement issues.

54 ENVIRONMENTAL SCIENCES↗

IAEA Sampling Plan

The objectives for this presentation are to describe the method that the IAEA uses to determine a sampling plan for nuclear material measurements; describe the terms detection probability and significant quantity; list the three nuclear materials measurement types; describe the sampling method applied to an item facility; and describe multiple method sampling.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗