Search NASA⌕ Search

SEARCH · Search NASA

Results for “segmentation averaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Date of Snowmelt at High Latitudes as Determined from Visible Satellite Data and Relationship with the Arctic Oscillation

Spring snow cover across Arctic lands has, on average, retreated approximately five days earlier since the late 1980s compared to the previous twenty years. However, it appears that since about 1990, the date the snowline first retreats north during the spring has remained nearly unchanged--in the last twenty years, the date of snow disappearance has not been occurring noticeably earlier. Snowmelt changes observed in the 1980s was step-like in nature, unlike a more continuous downward trend seen in Arctic sea ice extent. At latitude 70 deg N, several latitudinal segments (of 10 degrees) show significant (negative) trends. However, only two latitudinal segments at 60 deg N show significant trends, one positive and one negative. These variations appear to be related to variations in the Arctic Oscillation (AO). Additional observations and modeling investigations are needed to better explain past and present spring melt characteristics and peculiarities.

Foster, James↗

Investigation of Simple IMRT Delivery Techniques for Non-Small Cell Lung Cancer Patients with Respiratory Motion Using 4DCT

Techniques for generating simplified IMRT treatment plans for treating non-small cell lung cancer (NSCLC) patients with respiratory motion were investigated. To estimate and account for respiratory motion, 4-dimensional computed tomography (4DCT) datasets from 5 patients were used to design 5-field 6-MV ungated step-and-shoot intensity modulated radiotherapy (IMRT) plans delivering a dose of 66 Gy to the planning target volume (PTV). For each patient, 2 plans were generated using the mean intensity and the maximum intensity of 10 CT datasets from different breathing phases. The plans also utilized different margins around the clinical target volume/internal target volume (CTV/ITV) to account for tumor motion. To reduce the treatment time and ensure accurate dose delivery to moving targets, the number of intensity levels was minimized while maintaining dose coverage to PTV and minimizing dose to organs at risk (OARs). Dose-volume histograms (DVHs), dosimetric metrics, and outcome probabilities were evaluated for all plans. Plans using the averaged CT image dataset were inferior, requiring larger margins around the PTV, with a maximum of 1.5 cm, to ensure coverage of the tumor, and therefore increased the dose to OARs located in proximity of the tumor. The plans based on superimposed CT image datasets achieved full coverage of the tumor, while allowing tight margins around the PTV and minimizing the dose to OARs. A small number of intensity-levels (3 to 5), resulting in IMRT plans with a total of 13 to 30 segments, were sufficient for homogeneous PTV coverage, without affecting the sparing of OARs. In conclusion, a technique involving treatment planning with the superimposed CT scans of all respiratory phases, and the application of IMRT with only a small number of segments was feasible despite significant tumor motion; however, greater patient numbers are needed to support the statistical significance of the results presented in this work.

61 RADIATION PROTECTION AND DOSIMETRY↗

Topographic form of the Coast Ranges of the Cascadia Margin in relation ot coastal uplift rates and plate subduction

The Coast Ranges of the Cascadia margin are overriding the subducted Juan de Fuca/Gorda plate. We investigate the extent to which the latitudinal change in attributes related to the subduction process. These attributes include the varibale age of the subducted slab that underlies the Coast Ranges and average vertical crustal velocities of the western margin of the Coast Rnages for two markedly different time periods, the last 45 years and the last 100 kyr. These vertical crustal velocities are computed from the resurveying of highway bech marks and from the present elevation of shore platforms that have been uplifted in the late Quaternary, respectively. Topogarphy of the Coast Ranges is in part a function of the age and bouyancy of the underlying subducted plate. This is evident in the fact that the two highest topographic elements of the Coast Rnages, the Klamath Mountains and the Olympic Mountains, are underlain by youngest subducted oceanic crust. The subducted Blanco Fracture Zone in southernmost Oregon is responsible for an age discontinuity of subducted crust under the Klamath Mountains. The norhtern terminus of hte topographically higher Klamaths is offset to the north relative to the position of the underlying Blanco Fracture Zone, teh offset being in the direction of migration of the farcture zone, as dictated by relative plate motions. Vertical crustal velocities at the coast, derived from becnh mark surveys, are as much as an order of magnitude greater than vertical crustal velocities derived from uplifted shore platforms. This uplift rate discrepancy indicates that strain is accumulating on the plate margin, to be released during the next interplate earthquake. In a latitudinal sense, average Coast Rnage topography is relatively high where bench mark-derived, short-term vertical crustal velocities are highest. Becuase the shore platform vertical crustal velocities reflect longer-term, premanent uplift, we infer that a small percentage of the interseismic strain that accumulates as rapid short-term uplift is not recovered by subduction earthquakes but rather contributes to rock uplift of the Coast Ranges. The conjecture that permanent rock uplift is related to interseismic uplift is consistent with the observation that those segments of the subduction zone subject to greater interseismic uplift rates are at approximately the same latitudes as those segments of the Coast Ranges that have higher magnitudes of rock uplift over the long term.

Kelsey, Harvey M.↗

EXPLORING THE COSMIC REIONIZATION EPOCH IN FREQUENCY SPACE: AN IMPROVED APPROACH TO REMOVE THE FOREGROUND IN 21 cm TOMOGRAPHY

With the intent of correctly restoring the redshifted 21 cm signals emitted by neutral hydrogen during the cosmic reionization processes, we re-examine the separation approaches based on the quadratic polynomial fitting technique in frequency space in order to investigate whether they work satisfactorily with complex foreground by quantitatively evaluating the quality of restored 21 cm signals in terms of sample statistics. We construct the foreground model to characterize both spatial and spectral substructures of the real sky, and use it to simulate the observed radio spectra. By comparing between different separation approaches through statistical analysis of restored 21 cm spectra and corresponding power spectra, as well as their constraints on the mean halo bias b and average ionization fraction x{sub e} of the reionization processes, at z = 8 and the noise level of 60 mK we find that although the complex foreground can be well approximated with quadratic polynomial expansion, a significant part of the Mpc-scale components of the 21 cm signals (75% for {approx}> 6 h {sup -1} Mpc scales and 34% for {approx}> 1 h {sup -1} Mpc scales) is lost because it tends to be misidentified as part of the foreground when the single-narrow-segment separation approach is applied. The best restoration of the 21 cm signals and the tightest determination of b and x{sub e} can be obtained with the three-narrow-segment fitting technique as proposed in this paper. Similar results can be obtained at other redshifts.

79 ASTRONOMY AND ASTROPHYSICS↗

HIGH-RESOLUTION CO OBSERVATION OF THE CARBON STAR CIT 6 REVEALING THE SPIRAL STRUCTURE AND A NASCENT BIPOLAR OUTFLOW

CIT 6 is a carbon star in the transitional phase from the asymptotic giant branch (AGB) to the protoplanetary nebulae (pPNs). Observational evidences of two point sources in the optical, circumstellar arc segments in an HC{sub 3}N line emission, and a bipolar nebula in near-infrared provide strong support for the presence of a binary companion. Hence, CIT 6 is very attractive for studying the role of companions in the AGB–pPN transition. We have carried out high-resolution {sup 12}CO J = 2–1 and {sup 13}CO J = 2–1 observations of CIT 6 with the Submillimeter Array combined with the Submillimeter Telescope (single-dish) data. The {sup 12}CO channel maps reveal a spiral-shell pattern connecting the HC{sub 3}N segments in a continuous form and an asymmetric outflow corresponding to the near-infrared bipolar nebula. Rotation of the {sup 12}CO channel peak position may be related to the inner spiral winding and/or the bipolar outflow. An eccentric orbit binary is suggested for the presence of an anisotropic mass loss to the west and a double spiral pattern. The lack of interarm emission to the west may indicate a feature corresponding to the periastron passage of a highly eccentric orbit of the binary. Spatially averaged radial and spectral profiles of {sup 12}CO J = 2–1 and {sup 13}CO J = 2–1 are compared with simple spherical radiative transfer models, suggesting a change of {sup 12}CO/{sup 13}CO abundance ratio from ∼30 to ∼50 inward in the CSE of CIT 6. The millimeter continuum emission is decomposed into extended dust thermal emission (spectral index ∼ −2.4) and compact emission from radio photosphere (spectral index ∼ −2.0)

79 ASTRONOMY AND ASTROPHYSICS↗

TH-AB-207A-06: The Use of Realistic Phantoms to Predict CT Dose to Pediatric Patients

Purpose: To predict pediatric patient dose from diagnostic CT scans using Monte Carlo simulation of realistic reference phantoms of various ages, weights, and heights. Methods: A series of deformable pediatric reference phantoms using Non-Uniform Rational B-Splines (NURBS) was developed for a large range of ages, percentiles, and reference anatomy. Individual bones were modeled using age-dependent factors, and red marrow was modeled as functions of age and spatial distribution based on Cristy1. Organ and effective doses for the phantom series were calculated using Monte Carlo simulation of chest, abdominopelvic, and chest-abdomen-pelvis CT exams. Non-linear regression was performed to determine the relationship between dose-length-product (DLP)-normalized organ and effective doses and phantom diameter. Patient-specific voxel computational phantoms were also created by manual segmentation of previously acquired CT images for 40 pediatric patients (0.7 to 17 years). Organ and effective doses were determined by Monte Carlo simulation of these patient-specific phantoms. Each patient was matched to the closest pediatric reference phantom based primarily on age and diameter for all major organs within the torso. Results: A total of 80 NURBS phantoms were created ranging from newborn to 15 years with height/weight percentiles from 10 to 90%. Organ and effective dose normalized by DLP correlated strongly with exponentially decreasing average phantom diameter (R{sup 2} > 0.95 for most organs). A similar relationship was determined for the patient-specific voxel phantoms. Differences between patient-phantom matched organ-dose values ranged from 0.37 to 2.39 mGy (2.87% to 22.1%). Conclusion: Dose estimation using NURBS-based pediatric reference phantoms offers the ability to predict patient dose before and after CT examinations, and physicians and scientists can use this information in their analysis of dose prescriptions for particular subjects and study types. This may lead to practices that minimize radiation dose while still achieving high quality images and, ultimately, improved patient care. NIH/NCI 1 R01 CA155400-01A1.

60 APPLIED LIFE SCIENCES↗

Analysis of the Two-Level NO PLIF Model for Low-Temperature High-Speed Flow Applications

The current work compares experimentally obtained nitric oxide (NO) laser-induced fluorescence (LIF) spectra with the equivalent spectra obtained analytically. The experimental spectra are computed from captured images of fluorescence in a gas cell and from a laser sheet passing through the fuel-air mixing flowfield produced by a high-speed fuel injector. The fuel injector is a slender strut that is currently being studied as a part of the Enhanced Injection and Mixing Project (EIMP) at the NASA Langley Research Center. This injector is placed downstream of a Mach 6 facility nozzle, which simulates the high Mach number airflow at the entrance of a scramjet combustor, and injects helium, which is used as an inert substitute for hydrogen fuel. Experimental planar (P) LIF is obtained by using a UV laser to excite fluorescence from the NO molecules that are present in either a gas cell or the facility air used for the EIMP experiments. The experimental data are obtained for several segments of the NO fluorescence spectrum. The selected segments encompass LIF lines with rotational quantum numbers appropriate for low-to-moderate temperature flows similar to those corresponding to the nominal experimental flow conditions. The experimental LIF spectra are then evaluated from the data and compared with those obtained from the theoretical models. The theoretical spectra are obtained from LIFBASE and LINUS software, and from a simplified version of the two-level fluorescence model. The equivalent analytic PLIF images are also obtained by applying only the simplified model to the results of the Reynolds-averaged simulations (RAS) of the mixing flowfield. Good agreement between the experimental and theoretical results provides increased confidence in both the simplified LIF modeling and CFD simulations for further investigations of high-speed injector performance using this approach.

Drozda, Tomasz G.↗

Analysis of the Two-Level NO PLIF Model for Low-Temperature High-Speed Flow Applications

The current work compares experimentally obtained nitric oxide (NO) laser-induced fluorescence (LIF) spectra with the equivalent spectra obtained analytically. The experimental spectra are computed from captured images of fluorescence in a gas cell and from a laser sheet passing through the fuel-air mixing flowfield produced by a high-speed fuel injector. The fuel injector is a slender strut that is currently being studied as a part of the Enhanced Injection and Mixing Project (EIMP) at the NASA Langley Research Center. This injector is placed downstream of a Mach 6 facility nozzle, which simulates the high Mach number airflow at the entrance of a scramjet combustor, and injects helium, which is used as an inert substitute for hydrogen fuel. Experimental planar (P) LIF is obtained by using a UV laser to excite fluorescence from the NO molecules that are present in either a gas cell or the facility air used for the EIMP experiments. The experimental data are obtained for several segments of the NO fluorescence spectrum. The selected segments encompass LIF lines with rotational quantum numbers appropriate for low-to-moderate temperature flows similar to those corresponding to the nominal experimental flow conditions. The experimental LIF spectra are then evaluated from the data and compared with those obtained from the theoretical models. The theoretical spectra are obtained from LIFBASE and LINUS software, and from a simplified version of the two-level fluorescence model. The equivalent analytic PLIF images are also obtained by applying only the simplified model to the results of the Reynolds-averaged simulations (RAS) of the mixing flowfield. Good agreement between the experimental and theoretical results provides increased confidence in both the simplified LIF modeling and CFD simulations for further investigations of high-speed injector performance using this approach.

Tomasz G Drozda↗

Image segmentation for analyzing galaxy-galaxy strong lensing systems

The goal of this Letter is to develop a machine learning model to analyze the main gravitational lens and detect dark substructure (subhalos) within simulated images of strongly lensed galaxies. Using the technique of image segmentation, we turn the task of identifying subhalos into a classification problem, where we label each pixel in an image as coming from the main lens, a subhalo within a binned mass range, or neither. Our network is only trained on images with a single smooth lens and either zero or one subhalo near the Einstein ring. On an independent test set with lenses with large ellipticities, quadrupole and octopole moments, and for source apparent magnitudes between 17–25, the area of the main lens is recovered accurately. On average, only 1.3% of the true area is missed and 1.2% of the true area is added to another part of the lens. In addition, subhalos as light as 10 8.5 M ⊙ can be detected if they lie in bright pixels along the Einstein ring. Furthermore, the model is able to generalize to new contexts it has not been trained on, such as locating multiple subhalos with varying masses or more than one large smooth lens.

79 ASTRONOMY AND ASTROPHYSICS↗

Advanced Energy Retrofit Guide: Practical Ways to Improve Energy Performance, K-12 Schools (Book)

The U.S. Department of Energy developed the Advanced Energy Retrofit Guides (AERGs) to provide specific methodologies, information, and guidance to help energy managers and other stakeholders plan and execute energy efficiency improvements. Detailed technical discussion is fairly limited. Instead, we emphasize actionable information, practical methodologies, diverse case studies, and unbiased evaluations of the most promising retrofit energy efficiency measures for each building type. A series of AERGs is under development, addressing key segments of the commercial building stock. K-12 schools were selected as one of the highest priority building sectors, because schools affect the lives of most Americans. They also represent approximately 8% of the energy use and 10% of the floor area in commercial buildings nationwide. U.S. K-12 school districts spend more than $8 billion each year on energy - more than they spend on computers and textbooks combined. Most occupy older buildings that often have poor operational performance - more than 30% of schools were built before 1960. The average age of a school is about 42 years - which is nearly the expected serviceable lifespan of the building. K-12 schools offer unique opportunities for deep, cost-effective energy efficiency improvements, and this guide provides convenient and practical guidance for exploiting these opportunities in the context of public, private, and parochial schools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

TOWARD A METHOD FOR SCALING HUMAN BODY MODELS IN AN IMU-BASED WORKFLOW

BACKGROUND Scaled biomechanical models can more accurately inform crew health decisions when tailored to the wide range of astronaut sizes. One component to improve scaling of existing models to better represent each unique astronaut’s size is the individual length scaling of limbs. Traditionally, these lengths are determined by motion capture or manual measurement. A new method is herein proposed for length scaling which can be done by measuring linear and angular accelerations at a desired point during isolated motion around a point of rotation, then calculating the distance between the desired point and point of rotation. When an Inertial Measurement Unit (IMU) device is placed at the distal point of a limb, the isolated motion is about that limb’s proximal joint. For example, to measure forearm length, an IMU is placed at the wrist, the point of rotation is at the elbow, and the isolated motion is forearm flexion and extension. These calculated lengths are then used to scale models to each unique astronaut’s size, thereby improving the applicability of the model. This method of scaling limb segments can be used for any limb that has an easily defined proximal joint for the limb to rotate around including hands, arms, legs, feet. Utilizing IMUs for data collection also provides the synergistic ability to record data without a dedicated space in a room with many cameras, therefore reducing the data collection footprint, or record data where optical motion capture is not possible, such as inside a spacesuit. METHODS AND RESULTS To test this method, upper body data collection was performed with 5 Xsens DOT IMUs on a single subject. IMUs consist of an accelerometer, a gyroscope, and a magnetometer which collect linear acceleration, angular velocity, and magnetic fluctuations, respectively. Before any ground-based laboratory collection, the magnetic fluctuations are used to correct the heading of the IMU in space relative to the Earth’s magnetic field. The direct measurement of angular velocity is integrated to calculate angular acceleration. Then the linear acceleration ( a ) and angular acceleration (α) are solved using r = at/α to calculate the radius, which in this case is the distance between the IMU and the point of rotation (i.e., segment length). The IMU must be placed at the most distal point of the limb being measured (i.e., ankle if measuring lower leg length) and the test plan must consist of an isolated motion about that limb’s proximal joint (i.e., knee flexion and extension if measuring lower leg length). The distances (radii) calculated at every time interval were filtered (bandpass filter keeping 5th-90th percentile data) to eliminate outliers and spurious data that occur when the isolated motion was stopped or nearly stopped. The remaining distances were averaged, resulting in the calculated limb length. Scaling factors were then computed by dividing the calculated limb length by the unscaled model’s length. These scale factors are plugged into the Scale Tool in OpenSim [1,2] to apply the scaling to the OpenSim Full Body Rajagopal Model [3,4]. Manual measurements of limb lengths were taken before data collection started and used for comparing against the calculated lengths. The Anthropometric Survey of US Army Personnel (ANSUR II) [5] was also used as a third source of reference for limb length measurements. The following measurements were retrieved from the subject before data collection: 34.5 cm from L1 to C7 (thorax), 25.7 cm from C7 Joint Center (JC) to head vertex (neck and head), 36.3 cm from shoulder JC to elbow JC (humerus), 29.5 cm from elbow JC to wrist JC (forearm), and 16.2 cm from clavicle to acromion (clavicle). Of those five, forearm and humerus lengths were calculated using this proposed method to obtain preliminary results. The forearm length after filtering and averaging was calculated to be 37.6 cm. This is a 28% overestimation from the measured forearm length (29.5 cm). The humerus length after filtering and averaging was calculated to be 47.8 cm. This is a 31% difference from the measured subject length (36.3 cm). Sources of error include imperfect isolated motion (method currently expects that motion should be perfectly circular in a 2D plane, include no rotation of the IMU, and be relatively smooth; a more secure IMU attachment method will help), unrefined filter techniques (removed highest and lowest values with 20% high and low pass filters and no smoothing filters), arbitrary removal of stopped or near stopped data (kept data for only a short range before and after the angular velocity peaking), and a more representative method for removing gravitational acceleration is needed (current method is to zero all accelerations against a baseline taken just before the isolated motion which does not account for the gravitational acceleration changed due to IMU rotation during movement). Addressing these error sources will improve the accuracy of the limb length calculation. Next steps include creating a method for whole-body scaling estimation using individual limb scale factors. Continued pursuit of these techniques is expected to enable acquiring anthropometric information using only IMUs in real-time.

E. K. Marecki↗

Computerized detection of noncalcified plaques in coronary CT angiography: Evaluation of topological soft gradient prescreening method and luminal analysis

Purpose: The buildup of noncalcified plaques (NCPs) that are vulnerable to rupture in coronary arteries is a risk for myocardial infarction. Interpretation of coronary CT angiography (cCTA) to search for NCP is a challenging task for radiologists due to the low CT number of NCP, the large number of coronary arteries, and multiple phase CT acquisition. The authors conducted a preliminary study to develop machine learning method for automated detection of NCPs in cCTA. Methods: With IRB approval, a data set of 83 ECG-gated contrast enhanced cCTA scans with 120 NCPs was collected retrospectively from patient files. A multiscale coronary artery response and rolling balloon region growing (MSCAR-RBG) method was applied to each cCTA volume to extract the coronary arterial trees. Each extracted vessel was reformatted to a straightened volume composed of cCTA slices perpendicular to the vessel centerline. A topological soft-gradient (TSG) detection method was developed to prescreen for NCP candidates by analyzing the 2D topological features of the radial gradient field surface along the vessel wall. The NCP candidates were then characterized by a luminal analysis that used 3D geometric features to quantify the shape information and gray-level features to evaluate the density of the NCP candidates. With machine learning techniques, useful features were identified and combined into an NCP score to differentiate true NCPs from false positives (FPs). To evaluate the effectiveness of the image analysis methods, the authors performed tenfold cross-validation with the available data set. Receiver operating characteristic (ROC) analysis was used to assess the classification performance of individual features and the NCP score. The overall detection performance was estimated by free response ROC (FROC) analysis. Results: With our TSG prescreening method, a prescreening sensitivity of 92.5% (111/120) was achieved with a total of 1181 FPs (14.2 FPs/scan). On average, six features were selected during the tenfold cross-validation training. The average area under the ROC curve (AUC) value for training was 0.87 ± 0.01 and the AUC value for validation was 0.85 ± 0.01. Using the NCP score, FROC analysis of the validation set showed that the FP rates were reduced to 3.16, 1.90, and 1.39 FPs/scan at sensitivities of 90%, 80%, and 70%, respectively. Conclusions: The topological soft-gradient prescreening method in combination with the luminal analysis for FP reduction was effective for detection of NCPs in cCTA, including NCPs causing positive or negative vessel remodeling. The accuracy of vessel segmentation, tracking, and centerline identification has a strong impact on NCP detection. Studies are underway to further improve these techniques and reduce the FPs of the CADe system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Image Segmentation, Registration, Compression, and Matching

A novel computational framework was developed of a 2D affine invariant matching exploiting a parameter space. Named as affine invariant parameter space (AIPS), the technique can be applied to many image-processing and computer-vision problems, including image registration, template matching, and object tracking from image sequence. The AIPS is formed by the parameters in an affine combination of a set of feature points in the image plane. In cases where the entire image can be assumed to have undergone a single affine transformation, the new AIPS match metric and matching framework becomes very effective (compared with the state-of-the-art methods at the time of this reporting). No knowledge about scaling or any other transformation parameters need to be known a priori to apply the AIPS framework. An automated suite of software tools has been created to provide accurate image segmentation (for data cleaning) and high-quality 2D image and 3D surface registration (for fusing multi-resolution terrain, image, and map data). These tools are capable of supporting existing GIS toolkits already in the marketplace, and will also be usable in a stand-alone fashion. The toolkit applies novel algorithmic approaches for image segmentation, feature extraction, and registration of 2D imagery and 3D surface data, which supports first-pass, batched, fully automatic feature extraction (for segmentation), and registration. A hierarchical and adaptive approach is taken for achieving automatic feature extraction, segmentation, and registration. Surface registration is the process of aligning two (or more) data sets to a common coordinate system, during which the transformation between their different coordinate systems is determined. Also developed here are a novel, volumetric surface modeling and compression technique that provide both quality-guaranteed mesh surface approximations and compaction of the model sizes by efficiently coding the geometry and connectivity/topology components of the generated models. The highly efficient triangular mesh compression compacts the connectivity information at the rate of 1.5-4 bits per vertex (on average for triangle meshes), while reducing the 3D geometry by 40-50 percent. Finally, taking into consideration the characteristics of 3D terrain data, and using the innovative, regularized binary decomposition mesh modeling, a multistage, pattern-drive modeling, and compression technique has been developed to provide an effective framework for compressing digital elevation model (DEM) surfaces, high-resolution aerial imagery, and other types of NASA data.

Yadegar, Jacob↗

Motion as perturbation. II. Development of the method for dosimetric analysis of motion effects with fixed-gantry IMRT

Purpose: In this work, the feasibility of implementing a motion-perturbation approach to accurately estimate volumetric dose in the presence of organ motion—previously demonstrated for VMAT-–is studied for static gantry IMRT. The method's accuracy is improved for the voxels that have very low planned dose but acquire appreciable dose due to motion. The study describes the modified algorithm and its experimental validation and provides an example of a clinical application. Methods: A contoured region-of-interest is propagated according to the predefined motion kernel throughout time-resolved 4D phantom dose grids. This timed series of 3D dose grids is produced by the measurement-guided dose reconstruction algorithm, based on an irradiation of a staticARCCHECK (AC) helical dosimeter array (Sun Nuclear Corp., Melbourne, FL). Each moving voxel collects dose over the dynamic simulation. The difference in dose-to-moving voxel vs dose-to-static voxel in-phantom forms the basis of a motion perturbation correction that is applied to the corresponding voxel in the patient dataset. A new method to synchronize the accelerator and dosimeter clocks, applicable to fixed-gantry IMRT, was developed. Refinements to the algorithm account for the excursion of low dose voxels into high dose regions, causing appreciable dose increase due to motion (LDVE correction). For experimental validation, four plans using TG-119 structure sets and objectives were produced using segmented IMRT direct machine parameters optimization in Pinnacle treatment planning system (v. 9.6, Philips Radiation Oncology Systems, Fitchburg, WI). All beams were delivered with the gantry angle of 0°. Each beam was delivered three times: (1) to the static AC centered on the room lasers; (2) to a static phantom containing a MAPCHECK2 (MC2) planar diode array dosimeter (Sun Nuclear); and (3) to the moving MC2 phantom. The motion trajectory was an ellipse in the IEC XY plane, with 3 and 1.5 cm axes. The period was 5 s, with the resulting average motion speed of 1.45 cm/s. The motion-perturbed high resolution (2 mm voxel) volumetric dose grids on the MC2 phantom were generated for each beam. From each grid, a coronal dose plane at the detector level was extracted and compared to the corresponding moving MC2 measurement, using gamma analysis with both global (G) and local (L) dose-error normalization. Results: Using the TG-119 criteria of (3%G/3 mm), per beam average gamma analysis passing rates exceeded 95% in all cases. No individual beam had a passing rate below 91%. LDVE correction eliminated systematic disagreement patterns at the beams’ aperture edges. In a representative example, application of LDVE correction improved (2%L/2 mm) gamma analysis passing rate for an IMRT beam from 74% to 98%. Conclusions: The effect of motion on the moving region-of-interest IMRT dose can be estimated with a standard, static phantom QA measurement, provided the motion characteristics are independently known from 4D CT or otherwise. The motion-perturbed absolute dose estimates were validated by the direct planar diode array measurements, and were found to reliably agree with them in a homogeneous phantom.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-F-17A-06: Motion Stability and Dosimetric Impact of Spirometer-Based DIBH-RT of Left-Sided Breast Cancer

Purpose: Patients undergoing radiotherapy (RT) for left-sided breast cancer have increased risk of coronary artery disease. Deep Inhalation Breath Hold assisted RT (DIBH-RT) is shown to increase the geometric separation of the target area and heart, reducing cardiac radiation dose. The purposes of this study are to use Cine MV portal images to determine the stability of spirometer-guided DIBH-RT and examine the dosimetric cardiopulmonary impact of this technique. Methods: Twenty consecutive patients with left-sided breast cancer were recruited to the IRB-approved study. Free-breathing (FB) and DIBH-CT's were acquired at simulation. Rigid registration of the FB-CT and DIBH-CT was performed using primarily breast tissue. Treatment plans were created for each FB-CT and DIBH-CT using identical paired tangent fields with field-in-field or electronic compensation techniques. Dosimetric evaluation included mean and maximum (Dmax) doses for the left anterior descending artery (LAD), mean heart dose, and left lung V20. Cine MV portal images were acquired for medial and lateral fields during treatment. Analysis of Cine images involved chest wall segmentation using an algorithm developed in-house. Intra- and inter-fractional chest wall motion were determined through affine registration to the first frame of each Cine. Results: Dose to each cardiac structure evaluated was significantly (p<0.001) reduced with the DIBH plans. Mean heart dose decreased from 2.9(0.9–6.6) to 1.6(0.6–5.3) Gy; mean LAD dose from 16.6(3–43.6) to 7.4(1.7–32.7) Gy; and LAD Dmax from 35.4 (6.1–53) to 18.4(2.5–51.2) Gy. No statistically significant reduction was found for the left lung V20. Average AP and SI median chest wall motion (intrafractional) was 0.1 (SD=0.9) and 0.5 (SD=1.1) mm, respectively. Average AP inter-fractional chest wall motion was 2.0 (SD=1.4) mm. Conclusion: Spirometer-based DIBH treatments of the left breast are reproducible both inter- and intra-fractionally, and provide a statistically and potentially clinically useful dosimetric advantage to cardiac structures.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRB-04: A Novel Monolithic Silicon 2D Detector Array for Use in Stereotactic Applications

Purpose: To assess the capability of a novel 2D monolithic silicon detector array in measuring stereotactic photon fields. Methods: The silicon array detector used in this work, named Magic Plate-512 (MP512), is a thin monolithic silicon wafer (52 × 52 × 0.47 mm{sup 3}) with 512 ion-implanted diodes (0.5 × 0.5 mm{sup 2}). Adjacent pixels are spaced evenly with 2 mm pitch, covering a maximum detection area 46 mm wide. Its fast, FPGA based read-out system is synchronised with the linac to allow readout of all pixels pulse-by-pulse. A clinical SABR lung plan (consisting of 9 single segment beams, 6MV) was measured with the array at 1.5 cm depth in a solid water phantom (100 cm SSD). The typical field size was in the range of 3 × 3 cm{sup 2} to 4 × 4 cm{sup 2}. Each beam was delivered at perpendicular incidence to the detector plane so as to avoid the need for angular dependence corrections. The fields were measured under the same conditions using Gafchromic EBT3 film for comparison. The film was scanned at 72 dpi resolution, with the red channel data used for analysis. Results: Average gamma passing rates of (92.3 ± 1.8) % for 2%/2mm criteria, and (86.6 ± 2.3) % for 1%/2mm criteria were achieved for MP512, using EBT3 film as the reference distribution. The detector array was able to accurately measure the full-width-at-half-maximum (FWHM), to within (0.77 ± 0.01) mm accuracy when compared to film. The penumbral widths (80%-20%) were measured to within (0.30 ± 0.01) mm accuracy to film. Conclusion: The MP512 is a feasible option for measurement of stereotactic photon fields, with its high density of detection points making it useful for small field applications. The prototype array has demonstrated merit; in the future the development of a larger array detection area would be beneficial for clinical applications.

60 APPLIED LIFE SCIENCES↗

Global High Resolution Crustal Magnetic Field at the Surface of the Moon from Low-Altitude Lunar Prospector Magnetic Gradient Data

We derived new vector gradients based models of crustal magnetic field at the lunar surface with data from the Lunar Prospector (LP) satellite using two model parameterization approaches: a global set of 35820 1° spaced (~30 km) equal area monopoles at 20 km below the surface (O’Brien and Parker, 1994; Olsen et al., 2017) and combined results of subsets of 100000 0.66° spaced monopoles at the same depth. We use the scheme of iteratively reweighted least-squares inversion to compute the initial model. Then the amplitudes of these monopoles are determined by minimizing the misfit to the components together with the global average of |Br| at the ellipsoid surface (i.e. applying a L1 model regularization of Br). In previous approaches using vector fields for modeling, we found that external field contamination leads to spurious anomalies in the downward continued field models even with stringent data selection criteria and ad-hoc noise removal techniques (e.g., satellite’s position in the Moon’s wake w.r.t. the solar wind and in the Earth’s magnetotail, internal/external dipoles fields removal, low-order polynomial removal, joint equivalent source cross-validation technique and visually removing remaining anomalous segments). On the other hand, with the use of gradients-only data (along-track first finite differences), we were able to completely bypass the ad-hoc techniques. Similar processing of Kaguya magnetic data, which have only higher altitude coverage over the most of the Moon except in the region of the South Pole–Aitken (SPA) basin, completely misses some of the anomalies seen in the Lunar Prospector data. The combined Lunar Prospector and Kaguya gradient-based models also severely degrade the derivation of the anomaly fields in many regions. Euler analysis of isolated anomaly features from the Reiner Gamma swirl suggests top depths of about 0.3 to 1.5 km and center depths of 10-14 km; in the region between Stein and Vallier craters north of the SPA basin our analysis suggests top depths of around 1.5 km and center depths of 13-15 km. With the spectral depth determination techniques, the SPA basin region yields depths to the base of magnetization ranging between 15 and 40 km. Three-dimensional modeling and the bulk magnetization determinations of the sources constrained by the Euler and spectral methods is underway.

Gradient↗