Search NASA⌕ Search

SEARCH · Search NASA

Results for “sensor array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Ultrasensitive biochemical sensing device and method of sensing analytes

Systems and methods biochemically sense a concentration of a ligand using a sensor having a substrate having a metallic nanoparticle array formed onto a surface of the substrate. A light source is incident on the surface. A matrix is deposited over the nanoparticle array and contains a protein adapted to binding the ligand. A detector detects s-polarized and p-polarized light from the reflective surface. Spacing of nanoparticles in the array and wavelength of light are selected such that plasmon resonance occurs with an isotropic point such that -s and -p polarizations of the incident light result in substantially identical surface Plasmon resonance, wherein binding of the ligand to the protein shifts the resonance such that differences between the -S and -P polarizations give in a signal indicative of presence of the ligand.

47 OTHER INSTRUMENTATION↗

Readout IC requirement trends based on a simplified parametric seeker model.

Modern space based optical sensors place substantial demands on the focal plane array readout integrated circuit. Active pixel readout designs offer direct access to individual pixel data but require analog to digital conversion at or near each pixel. Thus, circuit designers must create precise, fundamentally analog circuitry within tightly constrained areas on the integrated circuit. Rapidly changing phenomena necessitate tradeoffs between sampling and conversion speed, data precision, and heat generation adjacent the detector array, especially of concern for thermally sensitive space grade infrared detectors. A simplified parametric model is presented that illustrates seeker system performance and analog to digital conversion requirements trends in the visible through mid-wave infrared, for varying sample rate. Notional limiting-case Earth optical backgrounds were generated using MODTRAN4 with a range of cloud extremes and approximate practical albedo limits for typical surface features from a composite of the Mosart and Aster spectral albedo databases. The dynamic range requirements imposed by these background spectra are discussed in the context of optical band selection and readout design impacts.

47 OTHER INSTRUMENTATION↗

Acoustic Observations of the OSIRIS-REx Sample Return Capsule Re-Entry from Wendover Airport

The Origins, Spectral Interpretation, Resource Identification, and Security‐Regolith Explorer sample return capsule (SRC) re‐entered the Earth’s atmosphere at hypersonic speeds from interplanetary space on 24 September 2023. The current work reports on 18 ground‐based acoustic sensors deployed at Wendover Airport, the same location that the Genesis and Stardust SRC re‐entries were recorded. Four different sensors (Chaparral Physics, Gem, Wilson Engineering Research and Development [WERD], and RedVox) were deployed in close proximity to compare their performance. All the sensors captured an N‐wave signal associated with the SRC re‐entry shock wave followed by a broadband coda. The Chaparral Physics array served as the high‐fidelity reference measurement. The N‐wave signal had a peak‐to‐peak amplitude of 4.07 Pa with a fundamental frequency of 4.98 Hz from 167.5° measured clockwise from north, nearly perpendicular to the SRC trajectory. In addition, high coherence in the coda was shown to be associated reflections from the surrounding mountains. In general, the more economical sensors (Gem, WERD, and RedVox) produced results that were consistent with these observations and sensor specifications. Beamforming with these single sensors arranged as an array showed agreement with the high‐fidelity array to within a couple of degrees. Furthermore, the current high‐fidelity results were compared with the measurements during the Genesis and Stardust SRC re‐entries. All three entries produced a broadband fundamental peak at a frequency that was inversely related to the SRC diameter as well as evidence of reflections from the surrounding topography.

KC, Real J. [Oklahoma State University, Stillwater↗

Comparison and Analysis of Instruments Measuring Plane-of-Array Irradiance for One-Axis Tracking Systems: Preprint

A variety of sensors are studied on a one-axis tracking surface and a horizontal surface in Golden, Colorado, and Eugene, Oregon. This is the first year of a long-term study that will look at not only a comparison between the instruments but also the longer-term degradation in calibration and/or performance. Initially, results from each location will be analyzed, and then results will be compared and contrasted between the two locations. A quick comparison at Eugene indicates that reference solar cells seem to compare better against a secondary standard pyranometer on a one-axis tracker than photodiode-based pyranometers. More study is needed to characterize and confirm this finding.

14 SOLAR ENERGY↗

Toward Fully Soft and Multifunctional Shape Sensing via Optical Waveguide Arrays

For soft bodies, surface deformation and pressure provide proprioceptive and exteroceptive information, including body configuration, body compliance, and external forces. We develop a sheet sensor with a fully soft sensing surface that provides surface shape reconstruction using optical waveguide arrays. The waveguides are fabricated to achieve a tunable linear response to bi‐directional bending curvature, and the waveguide arrays are configured to differentiate between ambiguous shapes. We characterize the waveguide performance, relating curvature sensitivity to the core's surface roughness. Synergy of waveguide responses reduces the number of sensing elements required and achieves damage resilience. Using waveguide sensitivity to pressure, we also demonstrate feasibility for exteroception. We demonstrate the multifunctional sensing capability by wrapping the sheet around an upper arm, showcasing joint motion and external force sensing. Integrated into or applied onto surfaces of robotic or living systems, this design can be implemented in applications such as virtual reality, teleoperation, physical therapy, and soft robotics.

Yu, Qifan [Department of Mechanical Engineering Ma↗

A High Resolution Monolithic Crystal, DOI, MR Compatible, PET Detector

The principle objective of this proposal is to develop a positron emission tomography (PET) detector with depth-of-interaction (DOI) positioning capability that will achieve state of the art spatial resolution and sensitivity performance for small animal PET imaging. When arranged in a ring or box detector geometry, the proposed detector module will support <1 mm 3 image resolution and >15% absolute detection efficiency. The detector will also be compatible with operation in a MR scanner to support simultaneous multi-modality imaging. The detector design will utilize a thick, monolithic crystal scintillator readout by a two-dimensional array of silicon photomultiplier (SiPM) devices using a novel sensor on the entrance surface (SES) design. Our hypothesis is that our single-ended readout SES design will provide an effective DOI positioning performance equivalent to more expensive dual-ended readout techniques and at a significantly lower cost. Our monolithic crystal design will also lead to a significantly lower cost system. It is our goal to design a detector with state of the art performance but at a price point that is affordable so the technology can be disseminated to many laboratories. A second hypothesis is that using SiPM arrays, the detector will be able to operate in a MR scanner without any degradation in performance to support simultaneous PET/MR imaging. Having a co-registered MR image will assist in radiotracer localization and may also be used for partial volume corrections to improve radiotracer uptake quantitation. The far reaching goal of this research is to develop technology for medical research that will lead to improvements in human health care.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, Fabrication, and Characterization of a Piezoelectric AFM Cantilever Array

Atomic force microscope (AFM) is a powerful instrument, which has been successfully employed in a myriad of applications from imaging to lithography, over the last decades. Despite its widespread use, low throughput of the AFM remains one of its major limitations along with slow scan rates in tapping mode. In this work, we propose a microfabricated cantilever array composed of five cantilevers, each equipped with onchip piezoelectric displacement sensors and an actuator for parallel imaging in tapping mode. The cantilevers are designed to have separate resonance frequencies in order to effectively minimize the vibrational coupling. The measured resonance frequencies range from 85.34 kHz to 107.78 kHz, and more than 5 kHz resonant frequency separation is achieved in the neighboring cantilevers. Vibrational coupling is mitigated by over two orders of magnitude compared to arrays with identical cantilevers. The common feedthrough problem in this type of active system is addressed by configuring the displacement sensors differentially. Finally, one of the cantilevers in the arrayis successfully employed for tapping mode AFM imaging.

42 ENGINEERING↗

Magnetization reversal in magnetic dot arrays: Nearest-neighbor interactions and global configurational anisotropy

Various proposals for future magnetic memories, data processing devices, and sensors rely on a precise control of the magnetization ground state and magnetization reversal process in periodically patterned media. In finite dot arrays, such control is hampered by the magnetostatic interactions between the nanomagnets, leading to the non-uniform magnetization state distributions throughout the sample while reversing. In this paper, we evidence how during reversal typical geometric arrangements of dots in an identical magnetization state appear that originate in the dominance of either Global Configurational Anisotropy or Nearest-Neighbor Magnetostatic interactions, which depends on the fields at which the magnetization reversal sets in. Based on our findings, we propose design rules to obtain the uniform magnetization state distributions throughout the array, and also suggest future research directions to achieve non-uniform state distributions of interest, e.g., when aiming at guiding spin wave edge-modes through dot arrays. Our insights are based on the Magneto-Optical Kerr Effect and Magnetic Force Microscopy measurements as well as the extensive micromagnetic simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bifacial PV test-bed irradiance measurements

Data for 2 front-facing and 4 rear-facing IMT irradiance sensors placed on a scaled-down setup that replicate a PV array in a highly-reflective rooftop. The test-bed consist of 3 rows of 20x2ft aluminum sheets (the “panels”), supported by a Unistrut structure, with 6 irradiance sensors (IMT) measuring front and rear irradiance in the center module of the center row. High quality weather-station data available

14 SOLAR ENERGY↗

Intelligent Sun Tracking for a CPV Power Plant

The output of a solar panel is strongly dependent on the amount of perpendicular light flux falling on its surface, and a tracking system tries to parallel the vector area of the solar panel surface to the incident solar flux. We present a tracking technique based on a two-axis sun sensor which can be used to increase the power output from a number of CPV arrays connected together in a solar power plant. The outdoor testing procedure of the developed two-axis sun sensor is discussed. The detail of the algorithm used together with the related sun tracking equipment is also presented and discussed for the new two axes sun tracking system.

14 SOLAR ENERGY↗

Helical Photonic Metamaterials for Encrypted Chiral Holograms

Helical structures are among the most quintessential three-dimensional (3D) forms that exhibit mirror asymmetry, a hallmark of chirality. Various structural parameters of helices directly linked to chiroptical properties highlight their importance as essential optical metamaterials for polarization-resolved sensors, imaging, and spectroscopies. However, such function-defining properties remain incompletely understood due to fabrication challenges and the lack of a relationship between structure and optical properties. Here, helical structures are analyzed parametrically, and correlations are established that are applicable to the design of chiral helical optical metamaterials. By systematically varying independent parameters—such as from single-turn to five-turn helices and from small major radii to larger ones optimized to fit the unit cell—the underlying relationships with ellipticty are revealed. In addition to theoretical modeling, the findings are experimentally validated using 3D printing and terahertz spectroscopy. The results demonstrate that optimized helical structures are mechanically tunable and exhibit unprecedented optical properties, including broadband and high-magnitude ellipticity spectra. Being embedded in soft elastomers, helical arrays can serve as soft, stretchable optical-mechanical sensors and holograms containing encoded information, such as barcodes and quick response (QR) codes. Chiral QR codes are realized using pixelated single helices with different handedness, demonstrating their potential as advanced encryption/decryption systems for security applications and chiral metaholograms.

Encrypted QR codes↗

A Portable 16-channel Magnetic Sensor for Human Magnetocardiographic Experiments

Here, we constructed a portable, low-cost 16-channel magnetic sensor for magnetocardiography (MCG) applications. The sensor is based on a high-sensitivity optically pumped magnetometer (OPM) with a novel configuration of nearly parallel pump and probe laser beams. The OPM-based 16-channel magnetic sensing is realized in a single module by using a fairly large rubidium vapor cell, broad pump/probe laser beams, and a 16-channel photodiode array, leading projected 10-fold reduction of the cost of sensors. The portability of the sensor is achieved by coupling the pump and probe lasers to OPM optics through multi-mode optical fibers. The 16-channel magnetic sensor is surrounded by a non-magnetic enclosure for safe operation. For MCG experiments with the sensor, its main components except lasers are located inside a magnetically shielded room (MSR), which reduces the ambient magnetic noise. The location of lasers and supporting electronics outside the MSR improves the sensitivity of the sensor. We report that the 16-channel magnetic sensor has a magnetic field sensitivity sufficient to directly detect the human cardiac magnetic signals.

16-channel magnetic sensing↗

A MAPS Based Micro-Vertex Detector for the STAR Experiment

For the 2014 heavy ion run of RHIC a new micro-vertex detector called the Heavy Flavor Tracker (HFT) was installed in the STAR experiment. The HFT consists of three detector subsystems with various silicon technologies arranged in 4 approximately concentric cylinders close to the STAR interaction point designed to improve the STAR detector’s vertex resolution and extend its measurement capabilities in the heavy flavor domain. The two innermost HFT layers are placed at radii of 2.8 cm and 8 cm from the beam line. These layers are constructed with 400 high resolution sensors based on CMOS Monolithic Active Pixel Sensor (MAPS) technology arranged in 10-sensor ladders mounted on 10 thin carbon fiber sectors to cover a total silicon area of 0.16 m 2 . Each sensor of this PiXeL (“PXL”) sub-detector combines a pixel array of 928 rows and 960 columns with a 20.7 μm pixel pitch together with front-end electronics and zero-suppression circuitry in one silicon die providing a sensitive area of ~3.8 cm 2 . This sensor architecture features 185.6 μs readout time and 170 mW/cm 2 power dissipation. This low power dissipation allows the PXL detector to be air-cooled, and with the sensors thinned down to 50 μm results in a global material budget of only 0.4% radiation length per layer. A novel mechanical approach to detector insertion allows us to effectively install and integrate the PXL sub-detector within a 12 hour period during an on-going multi-month data taking period. The detector requirements, architecture and design, as well as the performance after installation, are presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Studies of an array of PbF 2 Cherenkov crystals with large-area SiPM readout

Here, the electromagnetic calorimeter for the new muon (g-2) experiment at Fermilab will consist of arrays of PbF 2 Cherenkov crystals read out by large-area silicon photo-multiplier (SiPM) sensors. We report here on measurements and simulations using 2.0 - 4.5 GeV electrons with a 28-element prototype array. All data were obtained using fast waveform digitizers to accurately capture signal pulse shapes versus energy, impact position, angle, and crystal wrapping. The SiPMs were gain matched using a laser-based calibration system, which also provided a stabilization procedure that allowed gain correction to a level of 10 -4 per hour.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The calorimeter system of the new muon g -2 experiment at Fermilab

The electromagnetic calorimeter for the new muon ( g −2) experiment at Fermilab will consist of arrays of PbF 2 Čerenkov crystals read out by large-area silicon photo-multiplier (SiPM) sensors. We report here the requirements for this system, the achieved solution and the results obtained from a test beam using 2.0–4.5 GeV electrons with a 28-element prototype array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrochemical Applications of Microphase-Separated Block Copolymer Thin Films

In this work, we discuss electrochemical applications of electrode-supported thin films derived from microphase-separated block copolymers (BCPs). In contrast to conventional homopolymers used for electrode modification, BCPs afford periodic nanoscale structures (microdomains) of uniform dimensions (5-100 nm) and predictable morphologies, which can be controlled by adjusting the lengths of individual homopolymer segments. BCPs usable for electrochemical applications consist of two or more segments that form solute-permeable, redox-active or etchable microdomains and a chemically inert matrix. The resulting microdomains afford nanoscale molecular/charge transport pathways toward the underlying electrode, whereas the matrix serves as a scaffold to improve film stability in a solution. In conclusion, these polymeric thin films provide a unique means for fabricating nanowire arrays via template-based electrochemical synthesis, designing electrochemical sensors with unique selectivity, and constructing electrochemically-tunable functional materials.

36 MATERIALS SCIENCE↗

The role of trace gas flux networks in biogeosciences

Vast networks of meteorological sensors ring the globe, providing continuous measurements of an array of atmospheric state variables such as temperature, humidity, rainfall, and the concentration of carbon dioxide [New etal., 1999; Tans etal., 1996]. These measurements provide input to weather and climate models and are key to detecting trends in climate, greenhouse gases, and air pollution. Yet to understand how and why these atmospheric state variables vary in time and space, biogeoscientists need to know where, when, and at what rates important gases are flowing between the land and the atmosphere. Tracking trace gas fluxes provides information on plant or microbial metabolism and climate-ecosystem interactions. The existence of trace gas flux networks is a relatively new phenomenon, dating back to research in 1984. The first gas flux measurement networks were regional in scope and were designed to track pollutant gases such as sulfur dioxide, ozone, nitric acid, and nitrogen dioxide. Atmospheric observations and model simulations were used to infer the depositional rates of these hazardous chemicals [Fowler etal., 2009; Meyers etal., 1991]. In the late 1990s, two additional trace gas flux measurement networks emerged. One, the United States Trace Gas Network (TRAGNET), was a short-lived effort that measured trace gas emissions from the soil and plants with chambers distributed throughout the country [Ojima etal., 2000]. The other, FLUXNET, was an international endeavor that brought many regional networks together to measure the fluxes of carbon dioxide, water vapor, and sensible heat exchange with the eddy covariance technique [Baldocchi etal., 2001]. FLUXNET, which remains active today, currently includes more than 400 tower sites, dispersed across most of the world's climatic zones and biomes, with sites in North and South America, Europe, Asia, Africa, and Australia. More recently, several specialized networks have emerged, including networks dedicated to urban areas (Urban Fluxnet), nitrogen compounds in Europe (NitroEurope), and methane (MethaneNet). Technical Aspects of Flux Networks Eddy covariance flux measurements are the preferred method by which biogeoscientists measure trace gas exchange between ecosystems and the atmosphere [Baldocchi, 2003].

54 ENVIRONMENTAL SCIENCES↗

Development and Test of a 1,000 Level 3C Fiber Optic Borehole Seismic Receiver Array Applied to Carbon Sequestration

To address the critical site characterization and monitoring needs for CCS programs, US Department of Energy (DOE) awarded Paulsson, Inc. in 2010 a contract to design, build and test a fiber optic based ultra-large bandwidth clamped borehole seismic vector array capable of deploying up to one thousand 3C sensor pods suitable for deployment into high temperature and high pressure boreholes. Paulsson, Inc. has completed a design or a unique borehole seismic system consisting of a novel drill pipe based deployment system that includes a hydraulic clamping mechanism for the sensor pods, a new sensor pod design and most important – a unique fiber optic seismic vector sensor with technical specifications and capabilities that far exceed the state of the art seismic sensor technologies. These novel technologies were all applied to the new borehole seismic system. In combination these technologies will allow for the deployment of up to 1,000 3C sensor pods in vertical, deviated or horizontal wells. Laboratory tests of the fiber optic seismic vector sensors developed during this project have shown that the new borehole seismic sensor technology is capable of generating outstanding high vector fidelity data with extremely large bandwidth: 0.01 – 6,000 Hz. Field tests have shown that the system can record events at magnitudes much smaller than M-2.3 at frequencies up to 2,000 Hz. The sensors have also proved to be about 100 times more sensitive than the regular coil geophones that are used in borehole seismic systems today. The fiber optic seismic sensors have furthermore been qualified to operate at temperatures over 300°C (572°F). The fibers used for the seismic sensors in the system are used to record Distributed Temperature Sensor (DTS) data allowing additional value added data to be recorded simultaneously with the seismic vector sensor data.

01 COAL, LIGNITE, AND PEAT↗