The Evolution of Hot-Isostatic Pressing for the Treatment of Radioactive Wastes - 18276

Hot-isostatic Pressing (HIPing) was first developed by Battelle in the 1950's for applications in the nuclear program. The use of HIPing as a means of treating radioactive wastes was first proposed and patented in Sweden in the 1970's and subsequently gained traction in the US, where throughout the 1980's and 90's work was undertaken at Rockwell, Lawrence Livermore National Laboratory (LLNL), and Idaho National Laboratory (INL) on waste-forms for US Defense wastes. This development was coupled with front-end processing options leading to conceptual plant designs which included hot-cell layouts and costings. Industrial maturation of hot-isostatic press (HIP) technology over the last 20+ years has seen it increasingly become a candidate for treating a variety of waste streams. In this paper, we discuss HIP concepts for treating radioactive wastes, present some recent work undertaken by the authors to demonstrate the feasibility of HIPing for sludge wastes and ion exchangers, and discuss the options and technology challenges for implementation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nitric-glycolic flowsheet testing for maximum hydrogen generation rate

The Defense Waste Processing Facility (DWPF) at the Savannah River Site is developing for implementation a flowsheet with a new reductant to replace formic acid. Glycolic acid has been tested over the past several years and found to effectively replace the function of formic acid in the DWPF chemical process. The nitric-glycolic flowsheet reduces mercury, significantly lowers the chemical generation of hydrogen and ammonia, allows purge reduction in the Sludge Receipt and Adjustment Tank (SRAT), stabilizes the pH and chemistry in the SRAT and the Slurry Mix Evaporator (SME), allows for effective adjustment of the SRAT/SME rheology, and is favorable with respect to melter flammability. The objective of this work was to perform DWPF Chemical Process Cell (CPC) testing at conditions that would bound the catalytic hydrogen production for the nitric-glycolic flowsheet.

08 HYDROGEN↗

Alternative Treatment of Defense Waste Processing Facility Recycle via Reuse of Existing Liquid Waste Facilities - 20097

The Defense Waste Processing Facility (DWPF) at Savannah River Site (SRS) has been immobilizing high level waste since 1996. The chemical process within DWPF generates a large volume of condensate, which is recycled to the SRS H-Area Tank Farm. The recycle stream includes a small quantity of sludge solids, as well as soluble cesium that is volatilized during melter operation. The recycle waste is currently received into a large, underground waste tank that separates insoluble solids via decanting. The supernate is treated by an evaporator with a concentrate stream that is stored for future processing. The evaporator overheads are collected and sent to the Effluent Treatment Project (ETP) for final polishing and testing prior to discharge to local surface water. Recycle storage and treatment as described above complicates the overall mission within the tank farms, which are primarily engaged in waste retrieval and preparation activities that support sludge and salt disposition, as well as tank characterization and closure. The need to devote a portion of available storage space to recycle treatment limits operational flexibility, and ultimately the DWPF recycle stream must be diverted to fully close all the SRS waste tanks. An alternative treatment process is being explored to decouple the recycle stream from the tank farm. The proposed treatment process will accomplish solids separation via crossflow filtration and will utilize a wiped film evaporator to volume-reduce the filtrate stream. Evaporator overheads will continue to be further processed in ETP while the solids stream and evaporator concentrate stream will be returned for reprocessing with the DWPF and Salt Waste Processing Facility (SWPF). This process will utilize existing facilities within DWPF and the tank farm that were previously dedicated to Interim Salt Disposition (ISD), but no longer have an identified mission with the startup of SWPF. The reuse of these facilities will remove several constraints from the current Liquid Waste (LW) System Plan without expanding the current footprint of Department of Energy Environmental Management (EM) infrastructure within LW. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

DWPF Simulant CPC Studies for SB8

The Savannah River National Laboratory (SRNL) accepted a technical task request (TTR) from Waste Solidification Engineering to perform simulant tests to support the qualification of Sludge Batch 8 (SB8) and to develop the flowsheet for SB8 in the Defense Waste Processing Facility (DWPF). These efforts pertained to the DWPF Chemical Process Cell (CPC). Separate studies were conducted for frit development and glass properties (including REDOX). The SRNL CPC effort had two primary phases divided by the decision to drop Tank 12 from the SB8 constituents. This report focuses on the second phase with SB8 compositions that do not contain the Tank 12 piece.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High-Precision Plutonium Isotopic Compositions Measured on Los Alamos National Laboratory’s General’s Tanks Samples: Bearing on Model Ages, Reactor Modelling, and Sources of Material. Further Discussion of Chronometry

In this study, we re-analyzed late-1940’s, Manhattan Project era Plutonium-rich sludge samples recovered from the ''General’s Tanks'' located within the nation’s oldest Plutonium processing facility, Technical Area 21. These samples were initially characterized by lower accuracy, and lower precision mass spectrometric techniques. We report here information that was previously not discernable: the two tanks contain isotopically distinct Pu not only for the major (i.e., 240 Pu, 239 Pu) but trace ( 238 Pu , 241 Pu, 242 Pu) isotopes. Revised isotopics slightly changed the calculated 241 Am- 241 Pu model ages and interpretations.

54 ENVIRONMENTAL SCIENCES↗

Improving Efficiency of DWPF Operations via Automating Process Calculations and Vitrifying High-Curie Feed- 24529

The Liquid Waste Organization (LWO) at the Savannah River Site (SRS) uses a “Power As One®” motto to process and dispose of radioactive waste. The Defense Waste and Processing Facility (DWPF) treats the high-level waste through a process of vitrification. The DWPF receives three incoming waste streams that are added to the Sludge Receipt and Adjustment Tank (SRAT): sludge, Monosodium Titanate/Sludge Solids (MST/SS), and Strip Effluent (SE). The liquid waste is mixed with pre-fabricated frit and treated with high temperatures in the melter prior to being poured into stainless steel canisters. The liquid cools to form solid glass within these canisters that are suitable for long-term storage and disposal. Savannah River Mission Completion (SRMC), the SRS liquid waste contractor for the U.S. Department of Energy, has implemented several facility improvements to further enhance the operations to support the Liquid Waste Operation (LWO) mission. Two of these operational enhancements include implementing the electronic Material Tracking Program Calculator (eMTPC)software and increasing the DWPF canister heat rate limit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Updating the Default Anaerobic Digester Technology for Wastewater Sludge Anaerobic Digestion Pathways in R&D GREET 2025 Rev.1

The Greenhouse Gases, Regulated Emissions and Energy Use in Technologies model (R&D GREET) evaluates the life cycle impacts of renewable fuels and materials, including renewable natural gas (RNG) produced from wastewater (WW) sludge. In the sludge-to-RNG pathway, the assumed anaerobic digestion (AD) technology impacts results, such as energy use, greenhouse gases (GHG), and air pollutant emissions. Prior versions assumed sludge was fed through a thermal hydrolysis stage preceding the mesophilic AD (Thermohydrolysis). Such a process is expected to yield biosolids with sufficiently reduced pathogens to qualify for U.S Environmental Protection Agency (EPA) Class A designation. Other technologies, such as mesophilic AD without any advanced pretreatments, typically produce lower quality Class B biosolids but requires a lower energy burden and infrastructure investment. Table 1 displays the available AD technologies and the assumed resulting EPA biosolids class type from each technology. Full descriptions of each technology and their performance differences can be found in previous work.

09 BIOMASS FUELS↗

Alternate Methods for Eluting Cesium from Spherical Resorcinol-Formaldehyde Resin

A small-column ion exchange (SCIX) system has been proposed for removing cesium from the supernate and dissolved salt solutions in the high-level-waste tanks at the Savannah River Site (SRS). The SCIX system could use either crystalline silicotitanate (CST), an inorganic, non-regenerable sorbent, or spherical resorcinol-formaldehyde (RF), a new regenerable resin, to remove cesium from the waste solutions. The baseline method for eluting the cesium from the RF resin uses 15 bed volumes (BV) of 0.5 M nitric acid (HNO{sub 3}). The nitric acid eluate, containing the radioactive cesium, would be combined with the sludge from the waste tanks and would be converted into glass at the Defense Waste Processing Facility (DWPF) at SRS. The amount of nitric acid that would be used to elute the RF resin, using the current elution protocol, exceeds the capacity of DWPF to destroy the nitrate ions and maintain the required chemical reducing environment in the glass melt. Installing a denitration evaporator at SRS is technically feasible but would add considerable cost to the project. Alternate methods for eluting the resin have been tested, including using lower concentrations of nitric acid, other acids, and changing the flow regimes. About 4 BV of 0.5 M HNO{sub 3} are required to remove the sodium (titrate the resin) and most of the cesium from the resin, so the bulk of the acid used for the baseline elution method removes a very small quantity of cesium from the resin. A summary of the elution methods that have been tested are listed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alternate Methods For Eluting Cesium From Spherical Resorcinol-Formaldehyde Resin

A Small Column Ion Exchange (SCIX) system has been proposed for removing cesium from the supernate and dissolved salt solutions in the high level waste tanks at the Savannah River Site (SRS). The SCIX system could use either crystalline silicotitanate (CST) an inorganic, non-regenerable sorbent or spherical resorcinol-formaldehyde (RF), a new regenerable resin, to remove cesium from the waste solutions. The standard method for eluting the cesium from the RF resin uses 15-20 bed volumes (BV) of 0.5 M nitric acid (HNO3). The nitric acid eluate, containing the radioactive cesium, would be combined with the sludge from the waste tanks, and would be converted into glass at the Defense Waste Processing Facility (DWPF) at SRS. The amount of nitric acid generated by the standard elution method exceeds the capacity of DWPF to destroy the nitrate ions and maintain the required chemical reducing conditions in the glass melt. Alternate methods for eluting the resin have been tested, including using lower concentrations of nitric acid, other acids, and changing the flow regimes. About 4 bed volumes of 0.5 M nitric acid are required to remove the sodium (titrate the resin) and most of the cesium from the resin, so the bulk of the acid used for the standard elution method removes a very small quantity of cesium from the resin. The resin was loaded with 9.5 g Cs/L of resin prior to elution, which is the maximum expected loading for RF resin treating the actual dissolved salt waste at SRS. For the baseline elution method, 465 g of nitrate is used per liter of resin, and >99.9999% of the cesium is removed from the resin. An alternative method that used 4 bed volumes of 0.5 M HNO3 followed by 11 bed volumes of 0.05 M HNO3, used 158 g of nitrate per liter of resin (66% less nitrate than used for the standard elution) and removed >99.998% of the cesium. A staccato flow mode using 0.5 M HNO3 (1 hr on at 1 BV/hr, followed by 3 hrs off) after the resin had been titrated using a continuous flow of acid at 1 BV/hr removed 99.9998% of the cesium while using 12 BV of acid (20% less than the baseline). Formic acid was slightly less efficient than nitric acid for eluting the resin, but 20 BV of 0.5 M HCOOH removed 99.98% of the cesium from the resin.

Taylor, Paul Allen↗

Expansion of the Direct Feed High-Level Waste Glass Composition in the High Al Range

Baseline glass compositions have been developed and demonstrated for successful immobilization of Hanford high-level waste (HLW) prepared through a pretreatment process. Recent enhanced waste glass formulations have shown promise to increase the waste loading of pretreated sludge compositions from a broader range of HLW feeds. This project proposes to increase the loading of minimally pretreated Hanford HLW in glass by expanding the existing database and glass property-composition models. Estimated direct-feed high level waste (DFHLW) compositions were generated by the Hanford Tank Operations Contractor and used by Pacific Northwest National Laboratory to determine target glass compositions. Gaps in existing data were identified including one high-priority gap in the high Al compositional region. This report summarizes the data collected during the characterization of the DFHLW High Al Glass Matrix. These glasses were intentionally designed with high aluminum concentrations (15 to 30 wt%) and a high likelihood of nepheline formation, which is known to negatively affect glass durability. Some glasses were expected to either fail or approach property constraints to fill data gaps in poorly understood regions of the compositional space due to lack of data. Out of the 50 glasses tested, 14 glasses formed nepheline, while the model predicted nepheline formation in 20 glasses. All quenched glasses met the product consistency test durability constraint; however, 8 glasses failed this constraint after undergoing the canister centerline cooling treatment. Additionally, 17 glasses did not meet the viscosity constraints, 4 failed the EC constraints, and 2 exceeded the allowable T2% for spinel crystal formation. All glasses satisfied the SO 3 solubility limit. The resulting dataset provides valuable information to improve model accuracy and reduce prediction uncertainty. These insights will ultimately support the development of more robust glass formulation strategies, enabling higher waste loadings, reducing operational risks, and expanding the processing envelope.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SUCCESSES AND EMERGING ISSUES IN SIMULATING THE PROCESSING BEHAVIOR OF LIQUID-PARTICLE NUCLEAR WASTE SLURRIES AT THE SAVANNAH RIVER SITE - 205E

Slurries of inorganic solids, containing both stable and radioactive elements, were produced during the cold war as by-products of the production of plutonium and enriched uranium and stored in large tanks at the Savannah River Site. Some of this high level waste is being processed into a stable glass waste form today. Waste processing involves various large scale operations such as tank mixing, inter-tank transfers, washing, gravity settling and decanting, chemical adjustment, and vitrification. The rheological properties of waste slurries are of particular interest. Methods for modeling flow curve data and predicting the properties of slurry blends are particularly important during certain operational phases. Several methods have been evaluated to predict the rheological properties of sludge slurry blends from the data on the individual slurries. These have been relatively successful.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Soil bioassays as tools for sludge compost quality assessment

Composting is a waste management technology that is becoming more widespread as a response to the increasing production of sewage sludge and the pressure for its reuse in soil. In this study, different bioassays (plant germination, earthworm survival, biomass and reproduction, and collembolan survival and reproduction) were assessed for their usefulness in the compost quality assessment. Compost samples, from two different composting plants, were taken along the composting process, which were characterized and submitted to bioassays (plant germination and collembolan and earthworm performance). Results from our study indicate that the noxious effects of some of the compost samples observed in bioassays are related to the low organic matter stability of composts and the enhanced release of decomposition endproducts, with the exception of earthworms, which are favored. Plant germination and collembolan reproduction inhibition was generally associated with uncomposted sludge, while earthworm total biomass and reproduction were enhanced by these materials. On the other hand, earthworm and collembolan survival were unaffected by the degree of composting of the wastes. However, this pattern was clear in one of the composting procedures assessed, but less in the other, where the release of decomposition endproducts was lower due to its higher stability, indicating the sensitivity and usefulness of bioassays for the quality assessment of composts.

09 BIOMASS FUELS↗

Microbial Community Functional Structures in Wastewater Treatment Plants as Characterized by GeoChip

Background: Biological WWTPs must be functionally stable to continuously and steadily remove contaminants which rely upon the activity of complex microbial communities. However, knowledge is still lacking in regard to microbial community functional structures and their linkages to environmental variables. Aims: To investigate microbial community functional structures of activated sludge in wastewater treatment plants (WWTPs) and to understand the effects of environmental factors on their structure. Methods: 12 activated sludge samples were collected from four WWTPs in Beijing. A comprehensive functional gene array named GeoChip 4.2 was used to determine the microbial functional genes involved in a variety of biogeochemical processes such as carbon, nitrogen, phosphorous and sulfur cycles, metal resistance, antibiotic resistance and organic contaminant degradation. Results: High similarities of the microbial community functional structures were found among activated sludge samples from the four WWTPs, as shown by both diversity indices and the overlapped genes. For individual gene category, such as egl, amyA, lip, nirS, nirK, nosZ, ureC, ppx, ppk, aprA, dsrA, sox and benAB, there were a number of microorganisms shared by all 12 samples. Canonical correspondence analysis (CCA) showed that the microbial functional patterns were highly correlated with water temperature, dissolved oxygen (DO), ammonia concentrations and loading rate of chemical oxygen demand (COD). Based on the variance partitioning analyses (VPA), a total of 53% of microbial community variation from GeoChip data can be explained by wastewater characteristics (25%) and operational parameters (23%), respectively. Conclusions: This study provided an overall picture of microbial community functional structures of activated sludge in WWTPs and discerned the linkages between microbial communities and environmental variables in WWTPs.

54 ENVIRONMENTAL SCIENCES↗

WIPP WAC Equivalence Support Measurements for Low-Level Sludge Waste at Los Alamos National Laboratory - 12242

Los Alamos National Laboratory (LANL) uses the Nevada National Security Site (NNSS) as an off-site disposal facility for low-level waste (LLW), including sludge waste. NNSS has issued a position paper that indicates that systems that are not certified by the Carlsbad Field Office (CBFO) for Waste Isolation Pilot Plant (WIPP) disposal of Transuranic (TRU) waste must demonstrate equivalent practices to the CBFO certified systems in order to assign activity concentration values to assayed items without adding in the Total Measurement Uncertainty (TMU) when certifying waste for NNSS disposal. Efforts have been made to meet NNSS requirements to accept sludge waste for disposal at their facility. The LANL LLW Characterization Team uses portable high purity germanium (HPGe) detector systems for the nondestructive assay (NDA) of both debris and sludge LLW. A number of performance studies have been conducted historically by LANL to support the efficacy and quality of assay results generated by the LANL HPGe systems, and, while these detector systems are supported by these performance studies and used with LANL approved procedures and processes, they are not certified by CBFO for TRU waste disposal. Beginning in 2009, the LANL LLW Characterization Team undertook additional NDA measurements of both debris and sludge simulated waste containers to supplement existing studies and procedures to demonstrate full compliance with the NNSS position paper. Where possible, Performance Demonstration Project (PDP) drums were used for the waste matrix and PDP sources were used for the radioactive sources. Sludge drums are an example of a matrix with a uniform distribution of contaminants. When attempting to perform a gamma assay of a sludge drum, it is very important to adequately simulate this uniform distribution of radionuclides in order to accurately model the assay results. This was accomplished by using a spiral radial source tube placement in a sludge drum rather than the standard three source tubes seen in debris PDP drums. Available line sources (Eu-152) were placed in the spiral tubes to further accomplish the desired uniform distribution of radionuclides. The standard PDP drum (PDP matrix drum 005) and PDP sources were used to determine the lower limits of detection (LLD) and TMU. Analysis results for the sludge drum matrix case for two HPGe detectors were tabulated and evaluated. NNSS has accepted the methodology and results of the measurements towards demonstrating equivalence to CBFO certified systems. In conclusion, the WES-WGS and CMR-OPS gamma spectroscopy teams at LANL have defined and performed measurements that serve to establish and demonstrate equivalency with the processes used by CBFO certified NDA systems. The supplemental measurements address four key areas in Appendix A of DOE/WIPP-02-3122: Annual Calibration Confirmation and Performance Check measurements; LLD determination; and TMU definition. For these measurements the containers, matrices and activity loadings are selected to represent items being assayed in real LLW cases. The LLD and the TMU bounding measurements are to be performed one time and will not be required to be repeated in future campaigns. The annual calibration and performance check measurements were performed initially and planned to repeat in annual campaigns in order to maintain NNSS certification. PDP sources and a PDP sludge drum as well as Eu-152 line sources and a spiral sludge drum were used for the measurements. In all cases, the results for accuracy and precision (%R and %RSD, respectively) were within allowable ranges as defined by the WIPP PDP program. LLD (or MDC) results were established for all the ten WIPP reportable radionuclides and U-235, and the MDC for Pu-239 was established in all cases to be well under 100 nCi/g. Useful results for reducing estimated uncertainties were established and an interesting unexpected case of high bias was observed and will be applied toward this end. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preliminary Analysis of Species Partitioning in the DWPF Melter - Sludge Batch 7b

The goal of the work described in this report is to provide additional off-gas carryover data from the Defense Waste Processing Facility (DWPF) melter to support the estimation of off-gas carryover rates from the Low Activity Waste (LAW) melter at the Hanford Site. Of particular interest is to determine the volatility of technetium-99 (Tc-99), which is a key isotope of concern for disposal and is a significant challenge to retain in glass in the Hanford waste treatment flowsheet. Since the DWPF melter is not equipped with routine offgas monitoring and/or sampling capabilities, the off-gas carryover data had to be extracted using component mass balance of the measured feed and pour stream (PS) glass compositions under time-averaged melter operating conditions over the duration of one canister-filling cycle, typically 20-25 hours. The method was first tested using the Sludge Batch 6 (SB6) PS sample data taken while Canister #3472 was being filled on 12/20/2010, approximately three months after the (argon) glass bubblers were installed. The method was tested again using the SB7a PS sample data taken while Canister #3619 was being filled on 8/5/2011 with the glass bubblers in operation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Secondary Waste Form Down Selection Data Package – Ceramicrete

As part of high-level waste pretreatment and immobilized low activity waste processing, liquid secondary wastes will be generated that will be transferred to the Effluent Treatment Facility on the Hanford Site for further treatment. These liquid secondary wastes will be converted to stable solid waste forms that will be disposed in the Integrated Disposal Facility. Currently, four waste forms are being considered for stabilization and solidification of the liquid secondary wastes. These waste forms are Cast Stone, Ceramicrete, DuraLith, and Fluidized Bed Steam Reformer. The preferred alternative will be down selected from these four waste forms. Pacific Northwest National Laboratory is developing data packages to support the down selection process. The objective of the data packages is to identify, evaluate, and summarize the existing information on the four waste forms being considered for stabilization and solidification of the liquid secondary wastes. The information included will be based on information available in the open literature and from data obtained from testing currently underway. This data package is for the Ceramicrete waste form. Ceramicrete is a relatively new engineering material developed at Argonne National Laboratory to treat radioactive and hazardous waste streams (e.g., Wagh 2004; Wagh et al. 1999a, 2003; Singh et al. 2000). This cement-like waste form can be used to treat solids, liquids, and sludges by chemical immobilization, microencapsulation, and/or macroencapsulation. The Ceramicrete technology is based on chemical reaction between phosphate anions and metal cations to form a strong, dense, durable, low porosity matrix that immobilizes hazardous and radioactive contaminants as insoluble phosphates and microencapsulates insoluble radioactive components and other constituents that do not form phosphates. Ceramicrete is a type of phosphate-bonded ceramic, which are also known as chemically bonded phosphate ceramics. The Ceramicrete binder is formed through an acid-base reaction between calcined magnesium oxide (MgO; a base) and potassium hydrogen phosphate (KH{sub 2}PO{sub 4}; an acid) in aqueous solution. The reaction product sets at room temperature to form a highly crystalline material. During the reaction, the hazardous and radioactive contaminants also react with KH{sub 2}PO{sub 4} to form highly insoluble phosphates. In this data package, physical property and waste acceptance data for Ceramicrete waste forms fabricated with wastes having compositions that were similar to those expected for secondary waste effluents, as well as secondary waste effluent simulants from the Hanford Tank Waste Treatment and Immobilization Plant were reviewed. With the exception of one secondary waste form formulation (25FA+25 W+1B.A. fabricated with the mixed simulant did not meet the compressive strength requirement), all the Ceramicrete waste forms that were reviewed met or exceeded Integrated Disposal Facility waste acceptance criteria.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Caustic Recycling Pilot Unit to Separate Sodium from LLW at Hanford Site - 12279

As part of the Department of Energy (DOE) sponsored Advanced Remediation Technologies initiative, a scheme was developed to combine Continuous Sludge Leaching (CSL), Near-Tank Cesium Removal (NTCR), and Caustic Recycling Unit (CRU) using Ceramatec technology, into a single system known as the Pilot Near-Tank Treatment System (PNTTS). The Cesium (Cs) decontaminated effluent from the NTCR process will be sent to the caustic recycle process for recovery of the caustic which will be reused in another cycle of caustic leaching in the CSL process. Such an integrated mobile technology demonstration will give DOE the option to insert this process for sodium management at various sites in Hanford, and will minimize the addition of further sodium into the waste tanks. This allows for recycling of the caustic used to remove aluminum during sludge washing as a pretreatment step in the vitrification of radioactive waste which will decrease the Low Level Waste (LLW) volume by as much as 39%. The CRU pilot process was designed to recycle sodium in the form of pure sodium hydroxide. The basis for the design of the 1/4 scale pilot caustic recycling unit was to demonstrate the efficient operation of a larger scale system to recycle caustic from the NTCR effluent stream from the Parsons process. The CRU was designed to process 0.28 liter/minute of NTCR effluent, and generate 10 M concentration of 'usable' sodium hydroxide. The proposed process operates at 40 deg. C to provide additional aluminum solubility and then recover the sodium hydroxide to the point where the aluminum is saturated at 40 deg. C. A system was developed to safely separate and vent the gases generated during operation of the CRU with the production of 10 M sodium hydroxide. Caustic was produced at a rate between 1.9 to 9.3 kg/hr. The CRU was located inside an ISO container to allow for moving of the unit close to tank locations to process the LLW stream. Actual tests were conducted with the NTCR effluent simulant from the Parsons process in the CRU. The modular CRU is easily scalable as a standalone system for caustic recycling, or for NTTS integration or for use as an In-Tank Treatment System to process sodium bearing waste to meet LLW processing needs at the Hanford site. The standalone pilot operation of the CRU to recycle sodium from NTCR effluent places the technology demonstration at TRL level 6. Multiple operations were performed with the CRU to process up to 500 gallons of the NTCR effluent and demonstrate an efficient separation of up to 70 % of the sodium without solids precipitation while producing 10 M caustic. Batch mode operation was conducted to study the effects of chemistry variation, establish the processing rate, and optimize the process operating conditions to recycle caustic from the NTCR effluent. The performance of the CRU was monitored by tracking the density parameter to control the concentration of caustic produced. Different levels of sodium were separated in tests from the effluent at a fixed operating current density and temperature. The voltage of the modules remained stable during the unit operation which demonstrated steady operation to separate sodium from the NTCR effluent. The sodium transfer current efficiency was measured in testing based on the concentration of caustic produced. Measurements showed a current efficiency of 99.8% for sodium transfer from the NTCR effluent to make sodium hydroxide. The sodium and hydroxide contents of the anolyte (NTCR feed) and catholyte (caustic product) were measured before and after each batch test. In two separate batch tests, samples were taken at different levels of sodium separation and analyzed to determine the stability of the NTCR effluent after sodium separation. The stability characteristics and changes in physical and chemical properties of the NTCR effluent chemistry after separation of sodium hydroxide as a function of storage time were evaluated. Parameters such as level of precipitated alumina, total alkalinity, analysis of Al, Na, K, Cs, Fe, OH, nitrate, nitrite, total dissolved and undissolved solids, viscosity, density, and other parameters of the NTCR effluent were measured. Changes in rheology and properties of NTCR stream to support downstream handling of the effluent after sodium separation was the basis for the analysis. The results show that the NTCR effluent is stable without the precipitation of aluminum hydroxide after 70% of the sodium was separated from the effluent. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhanced, continuous, liquid-liquid extraction and in-situ separation of volatile fatty acids from fermentation broth

In 2018 alone, the US landfilled 35.3 million tons of food waste, about 24% of the total landfilled mass. In addition to the negative impacts landfills have demonstrated on the environment and human health, some states have begun to outlaw or dissuade the disposal of food waste and sewage sludge into landfills altogether. An urgent need has thus been created for the development of digestion processes like anaerobic digestion (AD) and arrested methanogenesis (AM) to convert food waste into valuable chemical products. Unfortunately, the buildup of volatile fatty acids (VFAs) during these processes eventually halts the reaction, and energy efficient methodologies for VFA removal are critical for the operation of fermenters. Additionally, VFAs themselves can serve as valuable chemical precursors, and recently AD processes have been modified to increase VFA production during fermentation. However, even with significant research over the past three decades, the separation of VFAs from the fermenter broth has remained expensive. Moreover, the separation of these VFAs from the fermenter broth may cost up to 50% of the entire process budget, hindering the widespread commercial adoption of AD and AM. Here we present a novel liquid-liquid extraction process termed CLEANS (Continuous Liquid-liquid Extraction And iN-situ Separation) as a highly efficient method for continuously separating VFAs from a real fermentation broth solely under gravity. Our optimized process (using an aqueous broth feed pH of 2.5, tri-noctylamine as an extractant, and a 10:1 ratio of aqueous broth to organic extractant), achieved a VFA distribution constant K D = 44.5 ± 7.9, a single-pass recovery = 81.3 ± 2.5%, and an extraction factor = 8.1 ± 0.3. These KD values are over an order of magnitude higher than what has been previously reported for comparable processes. A high aqueous-to-organic flowrate ratio, enabled for the first time by CLEANS, was found to be particularly crucial for achieving optimal extraction. Our separation process demonstrates excellent reproducibility and potential for scalability. The economic and environmental implications of this work are briefly discussed.