Search NASA⌕ Search

SEARCH · Search NASA

Results for “software estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

GMctdospp: Description and validation of a CT dose calculation system

Purpose: To develop a Monte Carlo (MC)-based computed tomography (CT) dose estimation method with a graphical user interface with options to define almost arbitrary simulation scenarios, to make calculations sufficiently fast for comfortable handling, and to make the software free of charge for general availability to the scientific community. Methods: A framework called GMctdospp was developed to calculate phantom and patient doses with the MC method based on the EGSnrc system. A CT scanner was modeled for testing and was adapted to half-value layer, beam-shaping filter, z-profile, and tube-current modulation (TCM). To validate the implemented variance reduction techniques, depth-dose and cross-profile calculations of a static beam were compared against DOSXYZnrc/EGSnrc. Measurements for beam energies of 80 and 120 kVp at several positions of a CT dose-index (CTDI) standard phantom were compared against calculations of the created CT model. Finally, the efficiency of the adapted code was benchmarked against EGSnrc defaults. Results: The CT scanner could be modeled accurately. The developed TCM scheme was confirmed by the dose measurement. A comparison of calculations to DOSXYZnrc showed no systematic differences. Measurements in a CTDI phantom could be reproduced within 2% average, with a maximal difference of about 6%. Efficiency improvements of about six orders of magnitude were observed for larger organ structures of a chest-examination protocol in a voxelized phantom. In these cases, simulations took 25 s to achieve a statistical uncertainty of ∼0.5%. Conclusions: A fast dose-calculation system for phantoms and patients in a CT examination was developed, successfully validated, and benchmarked. Influences of scan protocols, protection method, and other issues can be easily examined with the developed framework.

60 APPLIED LIFE SCIENCES↗

Development of a method to estimate organ doses for pediatric CT examinations

Purpose: To develop a method for estimating doses to primarily exposed organs in pediatric CT by taking into account patient size and automatic tube current modulation (ATCM). Methods: A Monte Carlo CT dosimetry software package, which creates patient-specific voxelized phantoms, accurately simulates CT exposures, and generates dose images depicting the energy imparted on the exposed volume, was used. Routine head, thorax, and abdomen/pelvis CT examinations in 92 pediatric patients, ranging from 1-month to 14-yr-old (49 boys and 43 girls), were simulated on a 64-slice CT scanner. Two sets of simulations were performed in each patient using (i) a fixed tube current (FTC) value over the entire examination length and (ii) the ATCM profile extracted from the DICOM header of the reconstructed images. Normalized to CTDI{sub vol} organ dose was derived for all primary irradiated radiosensitive organs. Normalized dose data were correlated to patient’s water equivalent diameter using log-transformed linear regression analysis. Results: The maximum percent difference in normalized organ dose between FTC and ATCM acquisitions was 10% for eyes in head, 26% for thymus in thorax, and 76% for kidneys in abdomen/pelvis. In most of the organs, the correlation between dose and water equivalent diameter was significantly improved in ATCM compared to FTC acquisitions (P < 0.001). Conclusions: The proposed method employs size specific CTDI{sub vol}-normalized organ dose coefficients for ATCM-activated and FTC acquisitions in pediatric CT. These coefficients are substantially different between ATCM and FTC modes of operation and enable a more accurate assessment of patient-specific organ dose in the clinical setting.

60 APPLIED LIFE SCIENCES↗

Performance Evaluation of Intelligent Solar Control Software Through Hardware-in-the-Loop (CRADA Final Report)

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been developed by Latimer Controls, Inc. to estimate the headroom of large PV plants for grid operation and control; however, these technologies lack comprehensive validation under real-world application scenarios. Latimer Controls, Inc. received two voucher awards for research at a national laboratory from the Department of Energy American Made Solar Prize Round 6. The National Renewable Energy Laboratory (NREL) was selected to collaborate with Latimer staff to conduct a performance evaluation of Latimer PV control software. The NREL team will develop a hardware-in-the-loop (HIL) testbed to perform testing and validation of the Latimer PV control technology in a de-risked yet realistic testbed environment. Latimer and NREL worked together to analyze the test data, draw conclusions from the results, and disseminate the resulting scientific findings. In this CRADA work, we propose to test and validate the real-world application of the Latimer Control solution in an HIL environment. We evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. In particular, a data-driven potential high limit (PHL) estimation is developed for large solar plants to accurately estimate their headroom so that they have fast and short-time regulation and control capability to participate in grid services and respond to grid signals in real time (e.g., AGC). This PHL estimation algorithm is embedded in a hardware power plant controller (PPC) and tested with an IEEE-39 bus system model developed in RTDS. To account for the varying cloud conditions and diverse inverter dispatches, we developed a 135-MW PV plant with detailed modeling of 27 individual PV modules and inverters using RTDS. The real-world communications used in such big plants, such as ModBus TCP/IP for inverter level and DNP3 for plant level, were developed to emulate the real-world applications in big PV plants. The ML-based PHL estimation method is tested under nine separate weather scenarios against the ‘reference-control’ solution, hereafter referred to as the baseline solution. The baseline method reserves a subset of inverters (reference group) to operate at their PHL at all times and dispatches only the remaining inverters (control group) at curtailed levels to fulfill the flexibility need. Despite being successfully piloted by NREL in California in 2017 and Chile in 2020, there exist two gaps in the state of the art to fully unlock the flexibility of PV plants: a. There is a trade-off between the PHL estimation accuracy and the flexibility range. b. There lacks granularity in the PHL estimation to capture the variation across inverters. The Latimer solution seeks to address these gaps by applying machine learning methods to improve PHL estimation accuracy while accounting for variability at every inverter. Performance metrics were taken from the 2023 Georgia Power CARES utility-scale RFP. The results demonstrate that the ML-based approach outperforms the traditional baseline method in PHL estimation accuracy for 7 of 9 scenarios. The average PHL error across the nine scenarios was 7.40% for the ML-based method, 2.06% less than the 9.46% PHL error average across scenarios that was exhibited by the baseline method. Additionally, the PHL error was below 5% for at least 95% of the testing interval for 3 of 9 tested intervals with the ML approach, whereas it did not achieve this metric for any of the baseline tests. Overall, simulation results indicate the superior performance of an ML-based approach compared to the conventional baseline reference-control approach, showcasing its potential to support grid stability and operational efficiency. This laboratory HIL testing using real PPC, representative power system simulation models in real-time with detailed PV plant and inverter models, and real-world communication protocols gives us confidence that this machine learning based PHL estimation algorithm works well in the hardware PPC and therefore de-risks future field commissioning. The end goal of this project is to advance grid technology to address the grid operation challenges brought by solar plant’s variability and uncertainties in power generation.

14 SOLAR ENERGY↗

Integrated Cost and Schedule using Monte Carlo Simulation of a CPM Model - 12419

This discussion of the recommended practice (RP) 57R-09 of AACE International defines the integrated analysis of schedule and cost risk to estimate the appropriate level of cost and schedule contingency reserve on projects. The main contribution of this RP is to include the impact of schedule risk on cost risk and hence on the need for cost contingency reserves. Additional benefits include the prioritizing of the risks to cost, some of which are risks to schedule, so that risk mitigation may be conducted in a cost-effective way, scatter diagrams of time-cost pairs for developing joint targets of time and cost, and probabilistic cash flow which shows cash flow at different levels of certainty. Integrating cost and schedule risk into one analysis based on the project schedule loaded with costed resources from the cost estimate provides both: (1) more accurate cost estimates than if the schedule risk were ignored or incorporated only partially, and (2) illustrates the importance of schedule risk to cost risk when the durations of activities using labor-type (time-dependent) resources are risky. Many activities such as detailed engineering, construction or software development are mainly conducted by people who need to be paid even if their work takes longer than scheduled. Level-of-effort resources, such as the project management team, are extreme examples of time-dependent resources, since if the project duration exceeds its planned duration the cost of these resources will increase over their budgeted amount. The integrated cost-schedule risk analysis is based on: - A high quality CPM schedule with logic tight enough so that it will provide the correct dates and critical paths during simulation automatically without manual intervention. - A contingency-free estimate of project costs that is loaded on the activities of the schedule. - Resolves inconsistencies between cost estimate and schedule that often creep into those documents as project execution proceeds. - Good-quality risk data that are usually collected in risk interviews of the project team, management and others knowledgeable in the risk of the project. The risks from the risk register are used as the basis of the risk data in the risk driver method. The risk driver method is based in the fundamental principle that identifiable risks drive overall cost and schedule risk. - A Monte Carlo simulation software program that can simulate schedule risk, burn WM2012 rate risk and time-independent resource risk. The results include the standard histograms and cumulative distributions of possible cost and time results for the project. However, by simulating both cost and time simultaneously we can collect the cost-time pairs of results and hence show the scatter diagram ('football chart') that indicates the joint probability of finishing on time and on budget. Also, we can derive the probabilistic cash flow for comparison with the time-phased project budget. Finally the risks to schedule completion and to cost can be prioritized, say at the P-80 level of confidence, to help focus the risk mitigation efforts. If the cost and schedule estimates including contingency reserves are not acceptable to the project stakeholders the project team should conduct risk mitigation workshops and studies, deciding which risk mitigation actions to take, and re-run the Monte Carlo simulation to determine the possible improvement to the project's objectives. Finally, it is recommended that the contingency reserves of cost and of time, calculated at a level that represents an acceptable degree of certainty and uncertainty for the project stakeholders, be added as a resource-loaded activity to the project schedule for strategic planning purposes. The risk analysis described in this paper is correct only for the current plan, represented by the schedule. The project contingency reserve of time and cost that are the main results of this analysis apply if that plan is to be followed. Of course project managers have the option of re-planning and re-scheduling in the face of new facts, in part by mitigating risk. This analysis identifies the high-priority risks to cost and to schedule, which assist the project manager in planning further risk mitigation. Some project managers reject the results and argue that they cannot possibly be so late or so overrun. Those project managers may be wasting an opportunity to mitigate risk and get a more favorable outcome. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preliminary proof-of-concept of real-time divertor heat flux control from infrared cameras with nitrogen injection in the DIII-D tokamak

In future tokamak reactors like ITER and the Fusion Pilot Plant (FPP), real-time feedback control of heat flux to the plasma-facing components (PFC) will be critical for steady-state operation. This work presents the first experimental demonstration of real-time divertor heat flux estimation with infrared thermography and feedback control with impurity seeding on the DIII-D tokamak. The flexible infrastructure of the Plasma Control System (PCS) on DIII-D makes this new capability possible. The PCS software runs on a gateway computer system, and five real-time compute nodes. An array of low latency streaming digitizers from D-TACQ Solutions connects to these real-time computers to collect and process data, and send commands to actuators during plasma discharges. This system handles the signal IO from the tokamak and allows the PCS to utilize the diagnostic data necessary to perform control in real-time. Feedback control on heat flux was accomplished by feeding infrared camera data from the “Infrared TV” (IRTV) camera to a custom-developed User Datagram Protocol (UDP) server. This server transmits infrared data to a newly developed PCS algorithm that estimates the heat flux to PFC. Here, a proportional integral derivative (PID) controller minimizes the error between a heat flux reference and the real-time estimate by injecting nitrogen gas into the divertor.

Algorithm development↗

The Predictive Power of SIMION/SDS Simulation Software for Modeling Ion Mobility Spectrometry Instruments

The combined use of SIMION 7.0 and the statistical diffusion simulation (SDS) user program in conjunction with SolidWorks® with COSMSOFloWorks® fluid dynamics software to model a complete, commercial ion mobility spectrometer (IMS) was demonstrated for the first time and compared to experimental results for tests using compounds of immediate interest in the security industry (e.g., 2,4,6-trinitrotoluene and cocaine). The effort of this research was to evaluate the predictive power of SIMION/SDS for application to IMS instruments. The simulation was evaluated against experimental results in three studies: 1) a drift:carrier gas flow rates study assesses the ability of SIMION/SDS to correctly predict the ion drift times; 2) a drift gas composition study evaluates the accuracy in predicting the resolution; and 3) a gate width study compares the simulated peak shape and peak intensity with the experimental values. SIMION/SDS successfully predicted the correct drift time, intensity, and resolution trends for the operating parameters studied. Despite the need for estimations and assumptions in the construction of the simulated instrument, SIMION/SDS was able to predict the resolution between two ion species in air within 3% accuracy. The preliminary success of IMS simulations using SIMION/SDS software holds great promise for the design of future instruments with enhanced performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-AB-207B-01: Dose Tolerance for SBRT/SABR

Purpose: Stereotactic body radiation therapy (SBRT) / stereotactic ablative body radiotherapy (SABR) is gaining popularity, but quantitative dose tolerance has still been lacking. To improve this, the April 2016 issue of Seminars in Radiation Oncology will have normal tissue complication probability (NTCP) models for 10 critical structures: optic pathway, cochlea, oral mucosa, esophagus, chestwall, aorta, bronchi, duodenum, small bowel, and spinal cord. Methods: The project included more than 1500 treatments in 1–5 fractions using CyberKnife, Gamma Knife, or LINAC, with 60 authors from 15 institutions. NTCP models were constructed from the 97 grade 2–3 complications, predominantly scored using the common terminology criteria for adverse events (CTCAEv4). Dose volume histogram (DVH) data from each institutional dataset was loaded into the DVH Evaluator software (DiversiLabs, LLC, Huntingdon Valley, Pa) for modeling. The current state of the literature for the critical structures was depicted using DVH Risk Maps: comparative graphs of dose tolerance limits that can include estimated risk levels, reported complications, DVH data for study patients, as well as high- and low-risk dose tolerance limits. Results: For relatively acceptable toxicity like grade 1–3 rib fractures and chestwall pain, the high-risk limits have 50% risk and the low-risk limits have 5% risk. Emami et al (IJROBP 1991 May 15;21(1):109–22) used 50% and 5% risk levels for all structures, whereas this effort used clinically acceptable ranges for each: in structures like aorta or spinal cord where complications must be avoided, the high- and low-risk limits have about 3% and 1% risk, respectively, in this issue of Seminars. These statistically based guidelines can help ensure plan quality for each patient. Conclusion: NTCP for SBRT is now becoming available. Hypofractionated dose tolerance can be dramatically different than extrapolations of conventional fractionation so NTCP analysis of the SBRT/SBRT data is important to ensure safe clinical practice. Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and was used to analyze the data.

60 APPLIED LIFE SCIENCES↗

Predicting 3D Motions from Single-Camera Optical Test Data

In a typical optical test, a stereo camera pair is required to measure the three-dimensional motion of a test article; one camera typically only measures motions in the image plane of the camera, and measurements in the out-of-plane direction are missing. Finite element expansion techniques provide a path to estimate responses from a test at unmeasured degrees of freedom. Treating the case of a single camera as a measurement with unmeasured degrees of freedom, a finite element model is used to expand to the missing third dimension of the image data, allowing a full-field, three-dimensional measurement to be obtained from a set of images from a single camera. The key to this technique relies on the mapping of finite element deformations to image deformations, creating a set of mode shape images that are used to filter the response in the image into modal responses. These modal responses are then applied to the finite element model to estimate physical responses at all finite element model degrees of freedom. The mapping from finite element model to image is achieved using synthetic images produced by a rendering software. Finally, the technique is applied first to a synthetic deformation image, and then is validated using an experimental set of images.

47 OTHER INSTRUMENTATION↗

DtaRefinery: a software tool for elimination of systematic errors from parent ion mass measurements in tandem mass spectra datasets

Hybrid two-stage mass spectrometers capable of both highly accurate mass measurement and MS/MS fragmentation have become widely available in recent years and have allowed for sig-nificantly better discrimination between true and false MS/MS pep-tide identifications by applying relatively narrow windows for maxi-mum allowable deviations for parent ion mass measurements. To fully gain the advantage of highly accurate parent ion mass meas-urements, it is important to limit systematic mass measurement errors. The DtaRefinery software tool can correct systematic errors in parent ion masses by reading a set of fragmentation spectra, searching for MS/MS peptide identifications, then fitting a model that can estimate systematic errors, and removing them. This results in a new fragmentation spectrum file with updated parent ion masses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Model-Reference Adaptive Direct-Power Control Scheme for Grid-Interactive Inverters

This paper develops an adaptive direct power control scheme for grid-interactive inverters while the control parameters are adaptively adjusted as the grid and filter parameters vary under different conditions. To demonstrate the efficacy and robustness of the adaptive operation, the performance of the adaptive controller is compared with a typical direct power controller by estimating the filter and grid impedances using a model reference parameter estimation technique with small signal injection. The simulation results verify that the developed methodology can track the reference power setpoints under output circuit parameter uncertainties while the typical design leads to instability. To improve the performance of the adaptive technique and eliminate the need for filter parameter estimation, a Lyapunov stability criterion-based model-reference adaptive direct power controller is designed to track the filter impedance. The developed method was tested using MATLAB/Simulink software to demonstrate the effectiveness of the proposed method. The results verify that adaptively tuning the control parameter can still maintain stable operation if the control gains are poorly selected while applying the classical method leads to abnormal operation or instability.

Gursoy, Mehmetcan↗

Weatherization Assistant NEAT/MHEA

The software provides a measure selection technique indicating cost effective retrofit activities that can be applied to a home using a standard Savings to Investment Ratio (SIR). Users must provide an input file describing the characteristics of the home to be evaluated. The software takes the input data provided and calculates energy savings and cost savings predicted for a standard set of measures given the input parameters. The Weatherization Assistant computes estimates of pre-retrofit whole building space heating and cooling energy consumptions based on the house description data supplied by the user. The consumptions are computed using a monthly heating and cooling variable base degree-day method by algorithms similar to those developed for the CIRA program [LBL, 1982]. The building consumptions are needed in computing the energy savings from measures affecting the efficiencies of the heating and cooling equipment. Weatherization Assistant then computes the energy savings and costs for each individual measure applicable to the building described as if it were the only measure installed in the house. From these energy savings, a discounted dollar savings over the life of each measure is computed. The ratio of this dollar savings to the cost of installing the measure, the "savings-to-investment ratio" (SIR), is used in an initial ranking of the measures' effectiveness. The "interacted" savings and SIR of measures are then determined assuming the measures are added to the house collectively, in order of their ranking, e.g., the second ranked measure is installed in the house initially described by the user after having been modified by the first ranked measure. If this second-ranked measure's updated SIR is greater than a user-defined limit, the measure is left implemented, else it is removed so that the next measure's effectiveness is not dependent on it. The choice between two mutually exclusive measures (such as different levels of insulation) is made on the basis of their "net present value" (NPV), the difference of life-time savings and installation cost, rather than their SIR. This has been shown to be the more correct criterion on which to base the selection between two measures, both of which cannot be installed. The audit computes and reports to the user the energy savings, discounted dollar savings, installation cost, and SIR for each measure considered cost-effective. For those with SIR greater than the user-designated cutoff, a materials list gives the material name, type, and quantity required for installation of the measure. Weatherization Assistant permits entry of pre-retrofit billing data for gas or electrically heated homes or homes with electric air-conditioning. The user may then make the decision to have the savings of the measures adjusted to reflect the difference in billed consumption and that predicted by the program.

Gettings, Michael↗

Validation of the Public Radiation Exposure Calculation for the Incident at the National Institute of Standards and Technology Center for Neutron Research on February 3, 2021

The Department of Energy/National Nuclear Security Administration Consequence Management Program was contacted by the Health Physics Chief of the National Institute of Standards and Technology Center for Neutron Research (NCNR) to review public radiation exposure calculations for an event that occurred on its Gaithersburg, Maryland, campus on February 3, 2021. Subject matter experts from the Nuclear Emergency Support Team (NEST) assets, specifically the Consequence Management Home Team (CMHT) and the National Atmospheric Release Advisory Center (NARAC), were selected to provide support. CMHT used three separate modeling codes to validate the results the scientists at NCNR calculated using the HotSpot model. The analyses were performed using NARAC’s in-house Lagrangian dispersion codes known as LODI and Aeolus, as well as the Turbo FRMAC software from Sandia National Laboratories. The team used parameters provided by the NCNR scientists regarding the site, applicable observable meteorological data, and environmental survey and sampling data to estimate public exposure. Each model estimated public dose at much less than 0.5 mrem. CMHT concurs with the NCNR public radiation exposure calculations which state that members of the public at the 400-meter boundary would have received a radiological dose of less than 0.5 mrem.

61 RADIATION PROTECTION AND DOSIMETRY↗

Regression for Assessing Contaminant Plume Trends

The Department of Energy’s (DOE) Hanford site has significant dissolved-phase groundwater contaminant plumes, for which remediation activities are ongoing. Assessing concentration trends is critical for making decisions regarding remedy implementation or performance. The SOCRATES single-page web application provides a quality-assured framework for data access and consistent data analytics using standard methods. To provide trend information for remedial decisions, statistical analyses based on ordinary least squares (OLS) are already supported by SOCRATES. The presence of censored data, however, can skew the result of an OLS regression. Other methods, such as the Akritas-Theil-Sen (ATS) or Tobit regressions can be more powerful. These two regression methods are used by Hanford site personnel to analyze groundwater contaminant concentration data, which often include nondetects (censored data). The ATS method uses comparisons of observation-pair ranks and the Tobit method uses a maximum likelihood estimation method. The Tobit method can also accommodate covariates, such as river stage or groundwater level fluctuations. Both ATS and Tobit regressions can be performed with the statistics software R, but to incorporate these methods into SOCRATES, their R code was ported into JavaScript. For quality assurance verification, the new code was tested with hexavalent chromium concentration data from the Hanford 100-K West Area and compared to regression analyses that were previously conducted on this data using R.

100-K Area↗

Reassessment of uncertainties for the PU-MET-INTER-002 benchmark - 14432

Uncertainty for the PU-MET-INTER-002 benchmark of ZPR-6/10 was unusually large for a ZPR assembly and was dominated by the uncertainties in matrix tube pitch and composition uncertainties for plutonium, graphite and stainless steel plates. The original uncertainty analysis for PU-MET-INTER-002 was limited by computer resources, software and the nuclear data available in 2002, all of which have been improved since. An as-built Monte Carlo model of ZPR-6/10 was used to quantify components of the transformation from the detailed model to a simplified RZ benchmark in 2002. Compositional uncertainties were estimated based upon TWODANT calculations of the RZ benchmark model (20 group, S{sub 8} - P{sub 1}). MC{sup 2}-2 was used with END/B-V.2 data to generate homogenized cross section data for TWODANT. The MC{sup 2}-2 calculations did not account for lattice cell spatial heterogeneity which was driven by the manual process required to generate ∼80 modifications to the deterministic model and by the software limitations of MC{sup 2}-2. Improvements to DIF3D-VARIANT, development of the MC{sup 2}-3 and BuildZPRModel codes, and better computer resources make accurate 3D transport calculations of reactivity changes practical today. BuildZPRModel imports the as-built geometry and creates a 'drawer' homogenized DIF3D model where each radial DIF3D mesh is the exact size of a single ZPR matrix tube and drawer. A MC{sup 2}-3 input is constructed for each drawer to produce homogenized cross section data where the spatial cell heterogeneity is captured by solving a 1D MOC transport calculation on the ultrafine energy group level. Collapsing 3D drawers into 1D MC{sup 2}-3 drawer models follows conventional procedures and is done by BuildZPRModel. MCNP6 was used to re-compute relevant geometry components of the uncertainty using ENDF/B-VII.0 data with the as-built model. Changes in the geometry components compared with earlier results are insignificant. DIF3D calculations of the compositional uncertainties were performed using 33, 70, 116, 230, 425, and 703 group energy structures and selectively combined with P{sub 3}-P{sub 7} transport approximations and P{sub 1} and P{sub 3} scattering kernels. 3D diffusion theory calculations were also performed for comparison. Many composition uncertainty components were essentially unchanged with the updated methodology. However, the dominant experimental uncertainty for PU-MET-INTER-002 is the composition of stainless steel. The new calculations reduce the stainless steel uncertainty from ∼115 pcm to ∼70 pcm which significantly reduces the total uncertainty for PU-MET-INTER-002. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Multi-Scale Computational Platform for Predictive Modeling of Corrosion in Al-Steel Joints (Final Report)

The research team proposed to develop innovative multi-scale models to predict corrosion and the resulting mechanical performances in aluminum-steel joints. The methods of joining considered are resistance spot welding, self-piercing riveting, and rivet-welding, all suitable for mass production applications. The multi-scale models integrate high throughput first-principle calculations based on density functional theory (DFT), high throughput calculation of phase diagrams (CALPHAD) modeling, and finite element method (FEM) simulations. These models are to be validated through laboratory experiments. Furthermore, the models are available as open source so as to enable scientists and engineers in the community to adapt and contribute to the development and application. The approaches rely on the research team’s extensive experience on the prediction of properties of individual phases at finite temperatures and variable compositions through DFT calculations, and our broad expertise on dissimilar material joining and their corrosion. The proposed computational framework enables high throughput computations for improved predictions of corrosion and the associated mechanical performance in dissimilar material joints, resulting in significant reduction in computational time needed by the current state-of-the-art methods. With the participation of researchers from three universities, an auto manufacturer, two manufacturing technology/equipment suppliers, and a software developer/vendor, the interdisciplinary research team applies the technical development on both phase-based modeling and laboratory experiments into the automobile body joining processes for validation and technology demonstration. The global cost of corrosion was estimated at about 3.4% of the global GDP in 2013. By using available corrosion control practices, it is estimated a saving between 15-35% of the cost of corrosion. In the U.S., more than $276 billion is spent repairing corrosion damage. Prediction of the corrosion and its impact on performance of the dissimilar material joints is critical for reducing the massive number of the current corrosion-based recalls for automobiles. Thus, the project goal is to develop models to enable predictive maintenance and end-of-life planning of multi-metal joints with risk of corrosion under different conditions such as exposure to high temperatures in summer and salt solutions in winter, quantified through its pH. An academia-industry consortium led by the University of Michigan and including Pennsylvania State University, University of Illinois Urbana-Champaign, University of Georgia, General Motors Company, Livermore Software Technology Corporation, and Optimal Process Technologies, LLC. created multi-scale models for prediction of corrosion in aluminum-steel joint structures such of them used in vehicle subassemblies – chassis and transmission systems. Starting from the first principle calculations, the team developed mathematical and data-driven models to predict the metallic components, which are formed during joining of two metals, for example aluminum and steel - a lightweight multilateral system which is currently used in more than 60% car bodies. These models were used for simulating chemical reactions that are happening when the joining metallic components are exposed to high temperatures and different pH values. The team was able to predict how the corrosion installs on the metallic components and how they lead to a sudden failure of components in cars. Newly developed machine learning algorithms combining Science, Technology, Engineering and Math disciplines, advanced finite element simulation and experimental validations have been integrated in a platform for prediction of the corrosion evolution and prediction the failure of joints under mechanical loadings and fatigue. Moreover, based on machine learning and inverse analysis, the team proposed solutions for designing new metallic alloys less susceptible to corrosion when joining multi-material assembles. An average of 4% error compared with experiments was achieved for the most common joints that are used in vehicle subassemblies.

36 MATERIALS SCIENCE↗

STAYSL PNNL Suite

The STAYSL PNNL Suite of software provides a set of tools for working with neutron activation rates measured in a nuclear fission reactor, an accelerator-based neutron source, or any neutron field to determine the neutron flux spectrum through a generalized least-squares approach. This process is referred to as neutron spectral adjustment since the preferred approach is to use measured data to adjust neutron spectra provided by neutron physics calculations. The input data consist of the reaction rates based on measured activities, an initial estimate of the neutron flux spectrum, neutron activation cross sections and their associated uncertainties (covariances), and relevant correction factors. The output consists of the adjusted neutron flux spectrum and associated covariance matrix, which is useful for neutron dosimetry and radiation damage calculations. The software suite consists of the STAYSL PNNL, SHIELD, BCF, and NJpp Fortran codes and the SigPhi Calculator spreadsheet tool. In addition, the development of this software suite and associated data libraries used the third-party NJOY99 Fortran code (http://t2.lanl.gov/nis/codes/njoy99/). The NJOY99 and NJpp codes are used to assemble cross section and covariance input data libraries (for both SHIELD and STAYSL PNNL) from the International Reactor Dosimetry File of 2002 (IRDF-2002; http://www-nds.iaea.org/irdf2002/) developed by the Nuclear Data Section of the International Atomic Energy Agency (Vienna, Austria). The BCF, SigPhi Calculator, and SHIELD software tools are used to calculate corrected activation rates and neutron self-shielding correction factors, which are inputs to the STAYSL PNNL code.

Greenwood, L.R.↗

Grid-Forming Control Using TAPAS Software Defined Inverters

Here, this paper discusses the design and hardware implementation aspects of state-feedback primary control for grid forming inverters. The primary control consists of two tracking control laws: voltage tracking and frequency/angle tracking. The voltage tracking control requires voltage and current at the inverter's switch terminal (i.e. before the filter). The fundamental component of switch terminal voltage is estimated using the inverter's average model while the switch terminal current is estimated using an observer, thus obviating the need for sensors at the switch terminals. The measurements of frequency and angle(s) needed for frequency/angle tracking are noisy due to measurement noises and inherent delays in the phase locked loop (PLL). Conditioning of these feedback signals is discussed in detail, and the corresponding changes in the control design are provided to better attenuate the impact of noises. Effectiveness of the proposed design and implementation is demonstrated by the implementation results from TAPAS software defined inverter (SDI).

24 POWER TRANSMISSION AND DISTRIBUTION↗

RouteE: A Vehicle Energy Consumption Prediction Engine

The emergence of connected and automated vehicles and smart cities technologies create the opportunity for new mobility modes and routing decision tools, among many others. To achieve maximum mobility and minimum energy consumption, it is critical to understand the energy cost of decisions and optimize accordingly. The Route Energy prediction model (RouteE) enables accurate estimation of energy consumption for a variety of vehicle types over trips or sub-trips where detailed drive cycle data are unavailable. Applications include vehicle route selection, energy accounting and optimization in transportation simulation, and corridor energy analyses, among others. The software is a Python package that includes a variety of pre-trained models from the National Renewable Energy Laboratory (NREL). However, RouteE also enables users to train custom models using their own data sets, making it a robust and valuable tool for both fast calculations and rigorous, data-rich research efforts. The pre-trained RouteE models are established using NREL's Future Automotive Systems Technology Simulator paired with approximately 1 million miles of drive cycle data from the Transportation Secure Data Center, resulting in energy consumption behavior estimates over a representative sample of driving conditions for the United States. Validations have been performed using on-road fuel consumption data for conventional and electrified vehicle powertrains. Transferring the results of the on-road validation to a larger set of real-world origin-destination pairs, it is estimated that implementing the present methodology in a green-routing application would accurately select the route that consumes the least fuel 90% of the time. The novel machine learning techniques used in RouteE make it a flexible and robust tool for a variety of transportation applications.

47 OTHER INSTRUMENTATION↗