Search NASA⌕ Search

SEARCH · Search NASA

Results for “source characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Assessment of Laser-Driven Pulsed Neutron Sources for Poolside Neutron-based Advanced NDE – A Pathway to LANSCE-like Characterization at INL

A variety of opportunities for characterization of fresh nuclear fuels using thermal (~25meV) and epithermal (~10eV) neutrons have been documented at Los Alamos National Laboratory. They include spatially resolved non-destructive characterization of features, isotopic enrichment, chemical heterogeneity and stoichiometry. The LANSCE spallation neutron source is well suited in neutron fluence and temporal characteristics for studies of fuels. However, recent advances in high power short pulse lasers suggest that compact neutron sources might, over the next decade, become viable at a price point that would permit their consideration for poolside characterization on site at irradiation facilities. In a laser-driven neutron source the laser is used to accelerate deuterium ions into a beryllium target where neutrons are produced. At this time, the technology is new and their total neutron production is approximately four orders of magnitude less than a facility like LANSCE. However, recent measurements on a sub-optimized system demonstrated >10 10 neutrons in sub-nanosecond pulses in predominantly forward direction. The compactness of the target system compared to a spallation target may allow exchanging the target during a measurement to e.g. characterize a highly radioactive sample with thermal, epithermal, and fast neutrons as well as hard X-rays, thus avoiding sample handling. At this time several groups are working on laser-driven neutron production and are advancing concepts for lasers, laser targets, and optimized neutron target/moderator systems. Advances in performance sufficient to enable poolside fuels characterization with LANSCE-like fluence on sample within a decade may be possible. This report describes the underlying physics and state-of-the-art of the laser-driven neutron production process from the perspective of the DOE/NE mission. It also discusses the development and understanding that will be necessary to provide customized capability for characterization of irradiated fuels. Potential operational advantages compared to a spallation neutron source include reduced shielding complexity, reduced energy requirements, and a production target free of fission products. Contributors to this report include experts in laser-driven neutron production (Roth, Fernandez), laser design (Haefner, Siders, Leemans), laser target design (Glenzer), spallation target/moderator design (Mocko), neutron instrumentation and characterization applications (Vogel, Bourke).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

THE NANOGRAV NINE-YEAR DATA SET: OBSERVATIONS, ARRIVAL TIME MEASUREMENTS, AND ANALYSIS OF 37 MILLISECOND PULSARS

We present high-precision timing observations spanning up to nine years for 37 millisecond pulsars monitored with the Green Bank and Arecibo radio telescopes as part of the North American Nanohertz Observatory for Gravitational Waves (NANOGrav) project. We describe the observational and instrumental setups used to collect the data, and methodology applied for calculating pulse times of arrival; these include novel methods for measuring instrumental offsets and characterizing low signal-to-noise ratio timing results. The time of arrival data are fit to a physical timing model for each source, including terms that characterize time-variable dispersion measure and frequency-dependent pulse shape evolution. In conjunction with the timing model fit, we have performed a Bayesian analysis of a parameterized timing noise model for each source, and detect evidence for excess low-frequency, or “red,” timing noise in 10 of the pulsars. For 5 of these cases this is likely due to interstellar medium propagation effects rather than intrisic spin variations. Subsequent papers in this series will present further analysis of this data set aimed at detecting or limiting the presence of nanohertz-frequency gravitational wave signals.

79 ASTRONOMY AND ASTROPHYSICS↗

VERIFICATION MEASUREMENTS OF THE MASS AND ENRICHMENT OF URANIUM OXIDE CARD SOURCES

Measurements were performed to determine the mass and enrichment of 10 uranium oxide (U3O8) card sources. The measurements and analysis were completed as a verification of the card sources in support of Oak Ridge National Laboratory’s nuclear material control and accountability program. Although these cards are not nationally accredited as a nuclear standard, they are used as a working reference for measurements, such as holdup. The uranium card source measurements were taken with a broad energy germanium detector and the Genie 2000 Gamma Acquisition and Analysis software. A complete characterization of each of the 10 uranium card sources was performed using the 4 characteristic full energy peaks of 235U. Using the In Situ Object Counting System software to determine the mathematical efficiency of the measurement, the mass of 235U in each card was determined. The 235U mass in each card ranged from 10.42 to 12.63 g with a systematic error between 0.76 and 0.95 g and a random error of 0.01 g for each card source. The Multi-Group Analysis for Uranium (MGAU) software and the Fixed-Energy, Response Function Analysis with Multiple Efficiency (FRAM) isotopic analysis software were used to determine the isotopic composition of the uranium cards. The measured enrichment was compared to the declared enrichment for each card, with uncertainties ranging from 2.7% to 4.3% for the MGAU analysis and 2.3% to 4.1% for the FRAM analysis. This is a good example of how a well-benchmarked mathematical calibration method can be useful in characterizing uranium sources.

Hunneke, Rachel↗

What Can Plastic Flow Fields Tell Us About Heat Sources in Deformation Processing?

We characterize primary (shape-change) and secondary (friction) deformation, and associated temperature fields, in metal cutting and forming processes, using in situ imaging and simulation. The experimental configurations enable access to the deformation zones and die contact-interfaces, for measuring deformation, temperature, and frictional drag. Infra-red thermography reveals that the plastic strain-rate field is an excellent proxy for the deformation-induced heat sources. Both spatially confined and diffuse strain-rate fields occur, depending on the initial workpiece deformation state. When the strain rate is confined, as in pre-hardened material, the temperature modeling is much simplified, as the heat source is also now localized. However complex, microstructure-driven deformation modes, like sinuous flow in annealed metals, result in spatially diffuse strain-rate and body heat sources, more challenging to analyze. Furthermore, our unified measurements should be of value for accurately estimating the fraction of plastic dissipation that is converted into heat in large-strain deformation processes.

36 MATERIALS SCIENCE↗

THE CELESTIAL REFERENCE FRAME AT 24 AND 43 GHz. II. IMAGING

We have measured the submilliarcsecond structure of 274 extragalactic sources at 24 and 43 GHz in order to assess their astrometric suitability for use in a high-frequency celestial reference frame (CRF). Ten sessions of observations with the Very Long Baseline Array have been conducted over the course of {approx}5 years, with a total of 1339 images produced for the 274 sources. There are several quantities that can be used to characterize the impact of intrinsic source structure on astrometric observations including the source flux density, the flux density variability, the source structure index, the source compactness, and the compactness variability. A detailed analysis of these imaging quantities shows that (1) our selection of compact sources from 8.4 GHz catalogs yielded sources with flux densities, averaged over the sessions in which each source was observed, of about 1 Jy at both 24 and 43 GHz, (2) on average the source flux densities at 24 GHz varied by 20%-25% relative to their mean values, with variations in the session-to-session flux density scale being less than 10%, (3) sources were found to be more compact with less intrinsic structure at higher frequencies, and (4) variations of the core radio emission relative to the total flux density of the source are less than 8% on average at 24 GHz. We conclude that the reduction in the effects due to source structure gained by observing at higher frequencies will result in an improved CRF and a pool of high-quality fiducial reference points for use in spacecraft navigation over the next decade.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantum description and properties of electrons emitted from pulsed nanotip electron sources

We present a quantum calculation of the electron degeneracy for electron sources. We explore quantum interference of electrons in the temporal and spatial domain and demonstrate how it can be utilized to characterize a pulsed electron source. We estimate effects of Coulomb repulsion on two-electron interference and show that currently available pulsed nanotip electron sources operate in the regime where the quantum nature of electrons can be made dominant.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Vector sensor-based acoustic monitoring system

An acoustic monitoring system characterizes, classifies, and geo-locates anthropogenic and natural sounds in near real time. The system includes a compact array of three acoustic vector sensors, which measures acoustic pressure and the three-dimensional particle velocity vector associated with the propagation of an acoustic wave, thereby inherently providing bearing information to an underwater source of sound. Beamforming techniques provide sound source localization, allowing for characterization of the acoustic signature of specific underwater acoustic sources.

Raghukumar, Kaustubha↗

Plasma potential and energy spread determination using ion beams extracted from an electron cyclotron resonance source

We have obtained estimates of plasma potentials and energy spreads characterizing an electron cyclotron resonance ion source plasma under different source conditions. Our estimates are obtained from analysis of ion beams extracted from the ion source at 10 kV that are subsequently decelerated into a floating surface scattering chamber where their current intensity incident on a solid sample is measured as function of retardation voltage. The deceleration occurs outside the measurement chamber, permitting beam current measurements in a field-free region. Absence of grids in the deceleration section avoids potential issues of field penetration. The behavior of our deceleration optics was modeled with SIMION. The simulation indicated a linear beam attenuation dependence close to full retardation where the beam current goes to zero. Deviations from this linear dependence observed close to zero beam energy give information on the initial energy spread of the ions extracted from the source. Our decelerated beams measurements are compared with recent in situ probe results and external beams results based on magnetic analysis.

43 PARTICLE ACCELERATORS↗

Characterizing physical, chemical, and magnetic properties at the nanoscale

Synchrotron light sources are extremely useful for the characterization of materials in many different research fields (including physics, chemistry, materials science, biology, medicine, geology, and cultural heritage). The evolution of technology, however, currently points toward the miniaturization of devices and molecular motors, as well as the creation (through atomic manipulation) of new materials. This brings an acute necessity for direct chemical imaging of materials, i.e., with the use of x-ray microscopy at the nanometer and atomic length scales.1, 2 Although a variety of new x-ray nanoprobes and x-ray microscopy techniques have been developed in recent years, the spatial resolution of direct chemical or magnetic contrast imaging techniques remains on the order of several nanometers. Invented in the 1980s, scanning tunneling microscopy (STM) allows a large range of materials to be viewed at the atomic level.3 STM also offers a finer degree of spatial resolution than almost any other image technique, but it is chemically ‘blind’ and thus cannot be used alone to directly identify chemical elements on a surface. For many years, researchers have attempted to solve this problem by combining STM with synchrotron x-ray excitations,4–7 and a new technique—known as synchrotron xray scanning tunneling microscopy (SX-STM)—has emerged. In this technique—which combines the chemical sensitivity of xrays with the high spatial resolution of STM—a monochromatic x-ray beam is used to illuminate a tip-sample junction, while the tip makes raster scans across the sample surface. A feedback system maintains a tip–sample separation that is typically less than 1nm. The goal is tomodulate the tunneling current through x-ray excitation and therewith obtain electronic and chemical contrast. It is difficult, however, to achieve real chemical contrast because of three serious issues. First, electrons excited by x-rays do not just tunnel into the tip, but can also be ejected from the sample and hit the sidewalls of the tip detector (which degrades the spatial resolution). Second, because photoejected electrons still provide a deceptive current signal in the far field, the STM feedback system can lift the tip out of the tunneling regime without being noticed. Last, themeasured tip current is always a convolution of the conventional tunnel current (which is related to the sample topography) and the x-ray-excited electrons (which carry the material’s chemical information).

36 MATERIALS SCIENCE↗

X-Ray Diffraction of Slag-Based Sodium Salt Waste Forms

Cementitious materials are used to solidify and stabilize aqueous based radioactive waste containing sodium salts. The types and proportions of cementitious ingredients used to treat aqueous radioactive waste streams containing sodium salts depend on the performance objectives for the waste forms and the compositions of the waste streams. Matrix phases can stabilize certain contaminants (co-precipitation, substitution, ion exchange, and / or sorption), influence processing properties, and are responsible for physical properties and durability of the cured waste forms. Consequently, characterization of the matrix (binder) mineralogy (chemical compositions and crystalline / non crystalline structures) is important for predicting contaminant leaching and evolution of the materials as a function of time and changing conditions This report documents sample preparation and x-ray diffraction results for a series of mixtures of sodium salt waste and cementitious binders. The objective of this study was to provide initial phase characterization for the CBP reference case cementitious salt waste form. This information can be used to: 1) generate a base line for the evolution of the waste form as a function of time and conditions, 2) potentially to design new binders based on mineralogy of the binder, 3) understand and predict anion and cation leaching behavior of contaminants of concern, and 4) predict performance of the waste forms for which phase solubility and thermodynamic data are available. Characterization of the mineralogy is also important for understanding the buffering effects that the waste form has on infiltrating water / leachates. More specifically, identification of hydrated phases capable of sequestering anions in the structures and crystallinity of the calcium silicate binder phases were of particular interest. The intent was to use this characterization data as a starting point for more detailed phase characterization using neutron diffraction techniques in addition to quasi-elastic neutron scattering techniques for characterization of water at the ORNL Spallation Neutron Source, Oak Ridge, TN. The initial characterization is complete. Due to extensive substitutions of cations and anions in the layered double hydroxide phases and the very fine intermixing of poorly crystalline hydrated phases in the reference case blend (10 : 45 : 45 cement : slag : fly ash), electron diffraction and transmission electron spectroscopy are recommended as the next step for characterization. In summary, the hydrated mixtures of Type II portland cement, Grade 100 ground granulated blast furnace slag (GGBFS) and carbon burn-out (CBO) Class F Fly ash contained hydrated phase assemblages which were typical of those reported in the literature. Based on x-ray diffraction results, no significant differences were detected in samples cured 2 months and 14 months in sealed containers at ambient indoor temperatures.

36 MATERIALS SCIENCE↗

International Data on Radiological Sources

ABSTRACT The mission of radiological dispersal device (RDD) nuclear forensics is to identify the provenance of nuclear and radiological materials used in RDDs and to aid law enforcement in tracking nuclear materials and routes. The application of databases to radiological forensics is to match RDD source material to a source model in the database, provide guidance regarding a possible second device, and aid the FBI by providing a short list of manufacturers and distributors, and ultimately to the last legal owner of the source. The Argonne/Idaho National Laboratory RDD attribution database is a powerful technical tool in radiological forensics. The database (1267 unique vendors) includes all sealed sources and a device registered in the U.S., is complemented by data from the IAEA Catalogue, and is supported by rigorous in-lab characterization of selected sealed sources regarding physical form, radiochemical composition, and age-dating profiles. Close working relationships with global partners in the commercial sealed sources industry provide invaluable technical information and expertise in the development of signature profiles. These profiles are critical to the down-selection of potential candidates in either pre- or post- event RDD attribution. The down-selection process includes a match between an interdicted (or detonated) source and a model in the database linked to one or more manufacturers and distributors.

07 ISOTOPE AND RADIATION SOURCES↗

Synthesis and characterization of microporous titanosilicate ETS-10 obtained with different Ti sources

Titanosilicate ETS-10 crystals were prepared by hydrothermal synthesis varying Ti source (TiCl{sub 3} and commercial TiO{sub 2}-anatase), time in autoclave and seeding with previously prepared ETS-10 crystals. The crystalline powders were characterized by X-ray diffraction, N{sub 2} adsorption, thermogravimetric analysis, and scanning and transmission electron microscopies. Control of the particle size of ETS-10 crystals ranging from 0.32 {mu}m x 0.41 {mu}m to 16.4 {mu}m x 32.5 {mu}m was successfully achieved varying the seeding and synthesis conditions. In particular, it was found that the use of TiO{sub 2}-anatase alone or together with TiCl{sub 3} promotes heterogeneous primary nucleation. Transmission electron microscopy demonstrated that the largest crystals obtained here were twinned.

36 MATERIALS SCIENCE↗

Configuration and impurity quantification of AmLi sources using radiography and gamma spectroscopy

This paper presents the non-destructive assay of two AmLi sources used for detector characterization and active interrogation at PNNL, identified as MRC-101 and MRC-103. First, a detailed description of the internal configuration of 2724-BT encapsulated MRC sources is established. X-ray radiographs of the AmLi sources are reported for the first time to verify the dimensions and orientation of the encapsulation. Notably, a density variation was observed as a contrast change across the height of the source cavities. Contrary to commonly made assumptions in literature, it is indirectly observed that the AmLi source/target material only occupies a portion of the source cavity. The intensity of the prompt gamma-rays resulting from the inelastic scatter of alpha particles on 7Li was used to calculate the mass ratios of LiH:AmO2. The gamma-ray spectra revealed the presence of numerous impurities in both source and target material (243Am, 237Np, 154Eu, 23Na, and 9Be). Neutron-gamma production ratios were applied to the intensity of the Doppler-broadened peaks from alpha-induced reactions with 7Li, 9Be, and 23Na to calculate neutron rates for both sources. A neutron/alpha production yield (derived in this work) was then related to the atomic concentration of these isotopes to find the approximate masses within each source. Ultimately, the AmLi source density was estimated with prompt gamma analysis based on partial source volumes as 0.45±0.08 g/cm^3.

DTRA, AmLi, neutron↗

Absolute calibration of the continuum x-ray spectrometer (ConSpec) at the National Ignition Facility

We illustrate the absolute calibration of the continuum x-ray spectrometer (ConSpec), designed to measure the hot-spot electron temperature of inertial confinement fusion (ICF) implosions at the National Ignition Facility (NIF). The spectrometer measures emission from photon energies of 20 to 30 keV where opacity effects in ICF implosions at the NIF are negligible and provides spatial resolution to separate the hot-spot emission from other x-ray sources, such as the gold emission from the hohlraum wall. Using a combination of x-ray ray tracing and calibration data taken using a well characterized x-ray source, we measure the dispersion, spatial resolution, and absolute sensitivity of the instrument. Finally, we present an example spectrum measured at the NIF and demonstrate the ability to measure the hot-spot electron temperature with uncertainty under 10%.

47 OTHER INSTRUMENTATION↗

Safety and Security of Radioactive Sealed and Disused/Orphan Sources in Ukraine - German Contribution - 13359

Within the scope of 'Nuclear Security of Radioactive Sources', the German government implemented the modernization of Ukrainian State Production Company's transport and storage facility for radioactive sources (TSF) in Kiev. The overall management of optimizing the physical protection of the storage facility (including the construction of a hot cell for handling the radioactive sources) is currently carried out by the German Federal Foreign Office (AA). AA jointly have assigned Gesellschaft fuer Anlagen- und Reaktorsicherheit (GRS) mbH, Germany's leading expert institution in the area of nuclear safety and waste management, to implement the project and to ensure transparency by financial and technical monitoring. Sealed radioactive sources are widely used in industry, medicine and research. Their life cycle starts with the production and finally ends with the interim/long-term storage of the disused sources. In Ukraine, IZOTOP is responsible for all radioactive sources throughout their life cycle. IZOTOP's transport and storage facility (TSF) is the only Ukrainian storage facility for factory-fresh radioactive sources up to an activity of about 1 million Ci (3.7 1016 Bq). The TSF is specially designed for the storage and handling of radioactive sources. Storage began in 1968, and is licensed by the Ukrainian state authorities. Beside the outdated state of TSF's physical protection and the vulnerability of the facility linked with it, the lack of a hot cell for handling and repacking radioactive sources on the site itself represents an additional potential hazard. The project, financed by the German Federal Foreign Office, aims to significantly improve the security of radioactive sources during their storage and handling at the TSF site. Main tasks of the project are a) the modernization of the physical protection of the TSF itself in order to prevent any unauthorized access to radioactive sources as well as b) the construction of a hot cell to reduce the number of transports of radioactive sources within the city of Kiev. In future, the new established hot cell at IZOTOP's transport and storage facility will be useful for identification and characterization of orphan/disused radioactive sources. The projects implemented are performed in accordance with international recommendations (e. g. IAEA) and national normative documents and will make a crucial contribution towards an improved safety and security management of radioactive sources in Ukraine. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Partial Charge Collection Induced by Neutron Damage in High-Purity Germanium Detectors

This paper investigates the correlation of damage induced by neutron interactions and degradation in the spectra of HPGe detectors. As neutrons kinetically interact with germanium crystals, they create interstitial and vacancy defects within the lattice. These defects then interfere with the charge migration of electron-hole pairs and reduce resolution in the observed energy spectrum. The partial charge collection produces observable spectral changes by increasing the peak width and reducing resolution (full width half maximum). A detailed characterization using various check sources was performed before and after iterations of neutron exposure in order to observe the effects of the neutron damage. An additional set of measurements was performed along with characterizations to show the detector’s response at discrete locations on the HPGe crystal. This was done to observe how the spectrum changes when the gamma rays are isolated to regions of various thicknesses of germanium. In order to impart damage, the detector was placed inside a californium shuffler with the face of the detector against the guide tube for the 252 Cf source. For irradiation of the HPGe, the source was then positioned in front of the face of the detector using the stepper motor of the shuffler. The neutron exposure time intervals were recorded and increased based on the initial damage observed. An MCNP simulation was performed to estimate the amount of interactions that occurred in the germanium crystal to ensure enough damage had occurred. Studying the effects that neutron damage imparts on a bullet-type HPGe detector can help provide necessary data to estimate total neutron exposure limits, reduce the likelihood of decisions made on suspect data, and aid in diagnostics of a damaged detector.

36 MATERIALS SCIENCE↗

Using ground-based measurements to recover the spectra of radiation escaping from distant light-pollution sources

ABSTRACT A professional dark sky assessment normally requires the numerical modelling of light propagation from ground-based sources into the atmosphere. The spectral power distribution (SPD) of light escaping from an artificial source is one of the key parameters needed in predicting models to simulate the optical signatures of the night sky as a function of distance. SPD at zero distance is due to a non-trivial superposition of light beams, but does not necessarily coincide with the weighted SPD of individual lights. This is because most photons can be removed by obstacles or can interact with many surfaces before being directed into the atmosphere. We have developed an experimental and theoretical method for obtaining the initial SPD from ground-based spectroscopy of the night sky. The method is applicable to distant sources of light and is demonstrated in field measurements conducted on the light dome of Chicago with a new sky glow spectrometer. We show that the method requires analysing the relative impact of local light sources scattered around the measuring site on the radiance of the light dome. Our theoretical method along with ground-based spectroscopy represents a new approach to characterizing light-pollution sources which are otherwise difficult to study due to lack of information on either light-source inventory or a heterogeneous 3D structure of light-emitting and blocking environments.

Kocifaj, M.↗

Advances in scientific literature mining for interpreting materials characterization

Abstract Using synchrotron light sources, such as the National Synchrotron Light Source II at Brookhaven National Laboratory, scientists in fields as diverse as physics, biology, and materials science, identify the atomic structure, chemical composition, or other important properties of varied specimens. x-ray spectroscopy from light sources is particularly valuable for materials research with vast information available about reference spectra in the scientific literature. However, as the technique is applicable to many science domains, searching for information about select x-ray spectroscopy spectra is impeded by the sheer number of publications. Moreover, useful information about the context of an experiment or figures presented in papers can be buried among the details, which takes time to assess. This work presents a scientific literature mining system that supports data acquisition, information extraction, and user interaction for referencing x-ray spectra identification and spectral interpretation. The goal is to provide efficient access to useful spectral data to researchers who may spend only a few days at a synchrotron light source. With this system, users browse a classification tree for papers arranged according to x-ray spectroscopic methods, chemical elements, and x-ray absorption spectroscopy edges. Relevant figures are extracted with sentences from the paper that explain them, known as ‘figure explanatory text.’ Notably, this system focuses on semantic aspects (logical analysis) to find figure explanatory text using deep contextualized word embeddings techniques and contains an interface to obtain labeled data from domain experts that is used to evaluate and improve the model.

Park, Gilchan (ORCID:0000000201536646)↗