Monitoring Surface Climate With its Emissivity Derived From Satellite Measurements

Satellite thermal infrared (IR) spectral emissivity data have been shown to be significant for atmospheric research and monitoring the Earth fs environment. Long-term and large-scale observations needed for global monitoring and research can be supplied by satellite-based remote sensing. Presented here is the global surface IR emissivity data retrieved from the last 5 years of Infrared Atmospheric Sounding Interferometer (IASI) measurements observed from the MetOp-A satellite. Monthly mean surface properties (i.e., skin temperature T(sub s) and emissivity spectra epsilon(sub v) with a spatial resolution of 0.5x0.5-degrees latitude-longitude are produced to monitor seasonal and inter-annual variations. We demonstrate that surface epsilon(sub v) and T(sub s) retrieved with IASI measurements can be used to assist in monitoring surface weather and surface climate change. Surface epsilon(sub v) together with T(sub s) from current and future operational satellites can be utilized as a means of long-term and large-scale monitoring of Earth 's surface weather environment and associated changes.

Zhou, Daniel K.↗

Effects of surface contamination on the infrared emissivity and visible-light scattering of highly reflective surfaces at cryogenic temperatures

A technique is described for the simultaneous in situ measurement of film thickness, refractive index, total normal emissivity, visible-light scattering, and reflectance of contaminant films on a highly reflective liquid-nitrogen cooled, stainless steel substrate. Emissivities and scattering data are obtained for films of water, carbon dioxide, silicone oil, and a number of aromatic and aliphatic hydrocarbons as a function of film thickness between zero and 20 microns. Of the contaminants investigated, water has by far the greatest effect on emissivity, followed by silicone oil, aliphatic hydrocarbons, aromatic hydrocarbons, and carbon dioxide. The emissivity increases more rapidly with film thickness between zero and 2.5 microns than at thicknesses greater than 2.5 microns. Scattering of visible light changes very little below 2 microns thickness but increases rapidly with thickness beyond 2 to 3 microns. The effect of contaminant films on passive radiation coolers is discussed.

Viehmann, W.↗

Effects of surface contamination on the infrared emissivity and visible-light scattering of highly reflective surfaces at cryogenic temperatures

A technique is described for the simultaneous in situ measurement of film thickness, refractive index, total normal emissivity, visible light scattering, and reflectance of contaminant films on a highly reflective liquid nitrogen-cooled, stainless steel substrate. Emissivities and scattering data were obtained for films of water, carbon dioxide, silicone oil, and a number of aromatic and aliphatic hydrocarbons as a function of film thickness between zero and 20 microns. Water had the greatest effect on emissivity, followed by silicone oil, aliphatic hydrocarbons, aromatic hydrocarbons, and carbon dioxide. Emissivity increased more rapidly with film thickness between zero and 2.5 microns, than at thickness greater than 2.5 microns. Scattering of visible light changed little below 2-microns thickness but increased rapidly with thickness beyond 2 to 3 microns. The effect of contaminant films on passive radiation coolers is discussed.

Viehmann, W.↗

Near-infrared Reflectance of Rocks at high Temperature: Preliminary Results and Implications for Near-infrared Emissivity of Venus's Surface

Light emitted from Venus’s surface can be viewed through spectral “windows” in its atmosphere, in the nearinfrared (NIR) around 1000 nanometer (nm) wavelengths. The NIR emissivity of Venus’s surface can constrain rock types and their weathering state; emissivities can be measured directly or calculated from reflectances. We measured the reflectances of igneous and sedimentary rocks at Venus’s surface temperature, 400 °C–500 °C at 850 and 950 nm; samples were heated in a box furnace in air, illuminated by light-emitting diodes (LEDs), and imaged with a modified charge-coupled device (CCD) camera. Reflectances were also measured at 25 °C from 350 to 1400 nm. Rock reflectances at 850 and 950 nm and 400 °C–500 °C are nearly identical to those at 25 °C, except for the effects of nanophase hematite forming on some surfaces. Fresh basalts have reflectances (high and low temperatures) near 7.5%; a leucogranite similarly has reflectances near 50%. Pigmentary hematite has nearly identical reflectances at high- and low-temperature at these wavelengths. Pigmentary hematite appears dark brown 400 °C–500 °C because its absorption edge has shifted to beyond the limit of human vision. These rock reflectances imply that basalts should have emissivities near 0.9, and granite (and similar felsic rocks) should have lower emissivities ∼0.5. Thus, basalt and felsic rock should be easily distinguished in NIR emissivity measurements of Venus’s surface, such as are baselined in recent Venus mission proposals. Other sedimentary rocks should have even lower emissivities: quartz sand at around ∼0.3, and anhydrite as low as 0.1.

Allan H Treiman↗

Analysis of the Behavior of Individual Emission Sites on the Surface of a Multi-Tip Field Cathode

A method of analysis of the surface of multi-tip field cathodes using data obtained with the aid of a computer-controlled field emission projector and a system of fast high-voltage scanning is described. An investigation of a polymer/carbon nanotube composite field electron emitter by this method was used to determine the distribution of individual emission sites over the surface of a multi-tip field cathode and to estimate variation of the work function of separate emission sites depending on the applied voltage. The contributions of separate groups of emission sites to a change of the shape of current–voltage characteristic of a multi-tip cathode have been numerically estimated.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

WE-AB-303-04: A Tissue Model of Cherenkov Emission From the Skin Surface During Megavoltage X-Ray Radiotherapy

Purpose: To develop a tissue model of Cherenkov radiation emitted from the skin surface during external beam radiotherapy. Imaging Cherenkov radiation emitted from human skin allows visualization of the beam position and potentially surface dose estimates, and our goal is to characterize the optical properties of these emissions. Methods: We developed a Monte Carlo model of Cherenkov radiation generated in a semi-infinite tissue slab by megavoltage x-ray beams with optical transmission properties determined by a two-layered skin model. We separate the skin into a dermal and an epidermal layer in our model, where distinct molecular absorbers modify the Cherenkov intensity spectrum in each layer while we approximate the scattering properties with Mie and Rayleigh scattering from the highly structured molecular organization found in human skin. Results: We report on the estimated distributions of the Cherenkov wavelength spectrum, emission angles, and surface distribution for the modeled irradiated skin surface. The expected intensity distribution of Cherenkov radiation emitted from skin shows a distinct intensity peak around 475 nm, the blue region of the visible spectrum, between a pair of optical absorption bands in hemoglobin and a broad plateau beginning near 600 nm and extending to at least 700 nm where melanin and hemoglobin absorption are both low. We also find that the Cherenkov intensity decreases with increasing angle from the surface normal, the majority being emitted within 20 degrees of the surface normal. Conclusion: Our estimate of the spectral distribution of Cherenkov radiation emitted from skin indicates an advantage to using imaging devices with long wavelength spectral responsivity. We also expect the most efficient imaging to be near the surface normal where the intensity is greatest; although for contoured surfaces, the relative intensity across the surface may appear to vary due to decreasing Cherenkov intensity with increased angle from the skin normal. This research was supported in part by a GAANN Fellowship from the Department of Education.

60 APPLIED LIFE SCIENCES↗

Detection of Crystalline Hematite Mineralization on Mars by the Thermal Emission Spectrometer: Evidence for Near-surface Water

The Thermal Emission Spectrometer (TES) instrument on the Mars Global Surveyor (MGS) mission has discovered a remarkable accumulation of crystalline hematite ((alpha-Fe2O3) that covers an area with very sharp boundaries approximately 350 by 350-750 km in size centered near 2 S latitude between 0 and 5 W longitude (Sinus Meridiani). Crystalline hematite is uniquely identified by the presence of fundamental vibrational absorption features centered near 300, 450, and >525/cm, and by the absence of silicate fundamentals in the 1000/cm region. Spectral features resulting from atmospheric CO2, dust, and water ice were removed using a radiative transfer model. The spectral properties unique to Sinus Meridiani were emphasized by removing the average spectrum of the surrounding region. The depth and shape of the hematite fundamental bands show that the hematite is crystalline and relatively coarse grained (>5-10 micron). Diameters up to and greater than 100s of micrometers are permitted within the instrumental noise and natural variability of hematite spectra. Hematite particles <5-10 micron in diameter (either as an unpacked or hard-packed powders) fail to match the TES spectra. The spectrally-derived areal abundance of hematite varies with particle size from approximately 10% for particles >30 micron in diameter to 40-60% for unpacked 10 micron powders. The hematite in Sinus Meridiani is thus distinct from the fine-grained (diameter <5-10 micron), red, crystalline hematite considered, on the basis of visible, near-IR data, to be a minor spectral component in Martian bright regions like Olympus-Amazonis. Sinus Meridiani hematite is closely associated with a smooth, layered, friable surface that is interpreted to be sedimentary in origin. This material may be the uppermost surface in the region, indicating that it could be a late-stage sedimentary unit, or it could be a layered portion of the heavily cratered plains units. We consider five possible mechanisms for the formation of coarse-grained, crystalline hematite. These processes fall into two classes depending on whether they require a significant amount of near-surface water: (1) chemical precipitation that includes origin by (a) precipitation from oxygenated, Fe-rich water (iron formations), (b) hydrothermal extraction and crystal growth.

Christensen, P. R.↗

Third Stokes parameter emission from a periodic water surface

An experiment in which the third Stokes parameter thermal emission from a periodic water surface was measured is documented. This parameter is shown to be related to the direction of periodicity of the periodic surface and to approach brightnesses of up to 30 K at X band for the surface used in the experiment. The surface actually analyzed was a 'two-layer' periodic surface; the theory of thermal emission from such a surface is derived and the theoretical results are found to be in good agreement with the experimental measurements. These results further the idea of using the third Stokes parameter emission as an indicator of wind direction over the ocean.

Johnson, J. T.↗

F.T. spectroscopy of OH produced in a microwave surface plasma

Emission spectra of the hydroxyl radical have been recorded between 450 and 4200/cm at 0.0027/cm unapodized resolution from an air+oxygen+water vapor plasma, using a surface microwave discharge. The characteristics of the source are described. The emission spectra were recorded with the F.T. spectrometer using a GeCu detector and KCl beams plitter. High J values were observed both for the pure rotational transition in v=0 and v=1 vibrational levels, and for the rovibrational transition in the 0-1 and 1-2 bands. The set of line intensity data will be used to compute the electric dipole moment function of OH.

Benidar, A.↗

Staircase and saw-tooth field emission steps from nanopatterned n-type GaSb surfaces

High resolution field emission experiments from nanopatterned GaSb surfaces consisting of densely packed nanocones prepared by low ion-beam-energy sputtering are presented. Both uncovered and metal-covered nanopatterned surfaces were studied. Surprisingly, the field emission takes place by regular steps in the field emitted current. Depending on the field, the steps are either regular, flat, plateaus, or saw-tooth shaped. To the author's knowledge, this is the first time that such results have been reported. Each discrete jump in the field emission may be understood in terms of resonant tunneling through an extended surface space charge region in an n-type, high aspect ratio, single GaSb nanocone. The staircase shape may be understood from the spatial distribution of the aspect ratio of the cones.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of total hemispherical emissivity of contaminated mirror surfaces

The effects of dust contamination on the total hemispherical emissivity (THE) of a 1.5-inch-diameter Al/MgF2-coated telescope mirror are investigated experimentally. The THE is determined by means of cooling-rate measurements in the temperature range 10-14.5 C in a vacuum of 100 ntorr or better. Photographs and drawings of the experimental setup are provided, and results for 11 dust levels are presented in tables and graphs. It is shown that dust has a significant effect on THE, but the experimental losses are only about half those predicted for perfectly black dust in perfect thermal contact with the mirror surface.

Facey, T. A.↗

Estimation of Critical Temperature for Surface Ion Currents from Electron Emission Data

A method of calculating a relation for the critical surface temperature for ion current emission is presented. The method is based on the S-shaped electron emission curves for surfaces in the presence of ionizable vapors and upon the assumptions of thermodynamic equilibrium involved in the Saha-Langmuir relation. A comparison of the critical temperatures so calculated with the relation obtained from actual ion emission data on the cesium-tungsten system shows good agreement over a wide current density range. Critical temperatures for cesium ion current densities of 0.21 and 1.9 amperes per square centimeter calculated by this method are presented for surfaces of rhenium, molybdenum, tantalum, and niobium. Tentative relations of the form log j equals A (sub p) plus (B (sub p) over T) are presented for these same systems, where j is the ion current density, A (sub p) and B (sub p) are constants, and T is the temperature.

ELECTRON EMISSION↗

Design and Impacts of Land-Biogenic-Atmosphere Coupling in the NASA-Unified WRF (NU-WRF) Modeling System

Land-Atmosphere coupling is typically designed and implemented independently for physical (e.g. water and energy) and chemical (e.g. biogenic emissions and surface depositions)-based models and applications. Differences in scale, data requirements, and physics thus limit the ability of Earth System models to be fully coupled in a consistent manner. In order for the physical-chemical-biological coupling to be complete, treatment of the land in terms of surface classification, condition, fluxes, and emissions must be considered simultaneously and coherently across all components. In this study, we investigate a coupling strategy for the NASA-Unified Weather Research and Forecasting (NU-WRF) model that incorporates the traditionally disparate fluxes of water and energy through NASA's LIS (Land Information System) and biogenic emissions through BEIS (Biogenic Emissions Inventory System) and MEGAN (Model of Emissions of Gases and Aerosols from Nature) into the atmosphere. In doing so, inconsistencies across model inputs and parameter data are resolved such that the emissions from a particular plant species are consistent with the heat and moisture fluxes calculated for that land cover type. In turn, the response of the atmospheric turbulence and mixing in the planetary boundary layer (PBL) acts on the identical surface type, fluxes, and emissions for each. In addition, the coupling of dust emission within the NU-WRF system is performed in order to ensure consistency and to maximize the benefit of high-resolution land representation in LIS. The impacts of those self-consistent components on' the simulation of atmospheric aerosols are then evaluated through the WRF-Chem-GOCART (Goddard Chemistry Aerosol Radiation and Transport) model. Overall, this ambitious project highlights the current difficulties and future potential of fully coupled. components. in Earth System models, and underscores the importance of the iLEAPS community in supporting improved knowledge of processes and innovative approaches for models and observations.

Tan, Qian↗

Improved Determination of Surface and Atmospheric Temperatures Using Only Shortwave AIRS Channels

The Goddard DAAC has been analyzing AIRS/AMSU sounding data using the AIRS Science Team Version 5 retrieval algorithm. The AIRS Version 5 retrieval algorithm produces significantly better temperature profiles under more difficult cloud conditions than does the AIRS Version 4 algorithm, because, following theoretical considerations, it employs 15 micron CO2 tropospheric sounding channels only for the purpose of generating cloud cleared radiances for all AIRS channels, and determines temperature profiles using only 4.2 micron AIRS observations. This approach works equally well during both daytime and night time conditions. The AIRS Version 6 retrieval algorithm takes this approach one step further, and now also determines surface skin temperatures over both land and ocean, using only shortwave AIRS window channel cloud cleared radiances. Shortwave surface spectral emissivity and spectral bi-directional reflectance are solved for simultaneously along with the surface skin temperature. Longwave surface spectral emissivity is determined in a subsequent step using only AIRS longwave window channels, using the previously determined surface skin temperature. The methodology to do this will be described, and results will be presented demonstrating significant improvement in retrieved surface skin temperatures and surface spectral emissivities compared to those obtained using Version 5, both day and night.

Susskind, Joel↗

Secondary electron emission properties of conducting surfaces for use in multistage depressed collectors

An Auger spectrometer in ultrahigh vacuum was used to measure the secondary emission properties of a number of candidate collector-materials including beryllium, carbon, (soot and pyrolytic graphite), copper, titanium carbide and tantalum. The advantage of the technique used is that the surface chemical constituents could be determined just before the secondary emission characteristics of the surface were measured. Pyrolytic graphite roughened by sputter etching showed the most favorable results for depressed collector use.

Forman, R.↗

Thermal infrared emission spectroscopy of natural surfaces: Application to desert varnish coatings on rocks

Thermal infrared spectroscopy has become an increasingly important tool for remote compositional analysis and geologic mapping. Most published laboratory measurements have been obtained in bidirectional reflection or transmission, whereas remotely sensed thermal infrared data are obtained by measuring the emitted energy. Section 2 of this paper describes a laboratory technique for determining calibrated emissivities of natural surfaces. Equations are developed to account for the energy reflected from the environment and to determine directly the sample temperature from measurements of hot and cold blackbody targets. Two methods for determining emissivity are developed: one in which only a hot sample measurement is made and the reflected background energy is removed by modeling, and a second in which the sample is cooled and the reflected energy is measured directly. Relative emissivity can be obtained to approximately 1% and absolute emissivities can be obtained to 2-15%, depending on the validity of the assumption that the emissivity of the sample is unity at some wavelength. The emission data agree well within the hemispherically integrated reflection data but point out probelms associated with bidirectional reflectance measurements. Section 3 applies emissivity measurements to the study of layered surfaces consisting of desert varnish coatings on granite and granodiorite rock suites. Two linear models are developed: the first assumes linear mixing of independent emission from the substrate and varnish (checkerboard model); the second models tansmission through an absorbing/emitting medium. Regardless of whether the varnish is or is not relatively transparant and strongly absorptive, the spectral effect of varnish increases linearly with varnish thickness, indicating that thick patches of varnish dominate the spectral properties. As a result, medium varnish thickness can be determined from spectral measurements. In addition, the composition of a substrate can be estimated through varnish layers up to 40-50 micrometers in median thickness, and the composition of the varnish material can be determined if the substrate material is known. The varnishes studied are composed primarily of clay materials, consistent with previous studies of varnish composition.

Christensen, Philip R.↗

Modeling of reduced effective secondary electron emission yield from a velvet surface

Complex structures on a material surface can significantly reduce total secondary electron emission from that surface. A velvet is a surface that consists of an array of vertically standing whiskers. The reduction occurs due to the capture of low-energy, true secondary electrons emitted at the bottom of the structure and on the sides of the velvet whiskers. We performed numerical simulations and developed an approximate analytical model that calculates the net secondary electron emission yield from a velvet surface as a function of the velvet whisker length and packing density, and the angle of incidence of primary electrons. We found that to suppress secondary electrons, the following condition on dimensionless parameters must be met: (π/2) DΑ tan θ >> 1, where theta is the angle of incidence of the primary electron from the normal, D is the fraction of surface area taken up by the velvet whisker bases, and A is the aspect ratio, A = h/r, the ratio of height to radius of the velvet whiskers. We find that velvets available today can reduce the secondary electron yield by 90% from the value of a flat surface. As a result, the values of optimal velvet whisker packing density that maximally suppresses the secondary electron emission yield are determined as a function of velvet aspect ratio and the electron angle of incidence.

36 MATERIALS SCIENCE↗