Search NASA⌕ Search

SEARCH · Search NASA

Results for “table detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

617 records · Page 35

A review of NEST models for liquid xenon and an exhaustive comparison with other approaches

This paper discusses the microphysical simulation of interactions in liquid xenon, the active detector medium in many leading rare-event searches for new physics, and describes experimental observables useful for understanding detector performance. The scintillation and ionization yield distributions for signal and background are presented using the Noble Element Simulation Technique (NEST), a toolkit based on experimental data and simple empirical formulas, which mimic previous microphysics modeling but are guided by data. The NEST models for light and charge production as a function of the particle type, energy, and electric field are reviewed, along with models for energy resolution and final pulse areas. NEST is compared with other models or sets of models and validated against real data, with several specific examples drawn from XENON, ZEPLIN, LUX, LZ, PandaX, and table-top experiments used for calibrations.

WIMPs↗

INFRARED AND ULTRAVIOLET STAR FORMATION IN BRIGHTEST CLUSTER GALAXIES IN THE ACCEPT SAMPLE

We present infrared (IR) and ultraviolet (UV) photometry for a sample of brightest cluster galaxies (BCGs). The BCGs are from a heterogeneous but uniformly characterized sample, the Archive of Chandra Cluster Entropy Profile Tables (ACCEPT), of X-ray galaxy clusters from the Chandra X-ray telescope archive with published gas temperature, density, and entropy profiles. We use archival Galaxy Evolution Explorer (GALEX), Spitzer Space Telescope, and Two Micron All Sky Survey (2MASS) observations to assemble spectral energy distributions (SEDs) and colors for BCGs. We find that while the SEDs of some BCGs follow the expectation of red, dust-free old stellar populations, many exhibit signatures of recent star formation in the form of excess UV or mid-IR emission, or both. We establish a mean near-UV (NUV) to 2MASS K color of 6.59 {+-} 0.34 for quiescent BCGs. We use this mean color to quantify the UV excess associated with star formation in the active BCGs. We use both fits to a template of an evolved stellar population and library of starburst models and mid-IR star formation relations to estimate the obscured star formation rates (SFRs). We show that many of the BCGs in X-ray clusters with low central gas entropy exhibit enhanced UV (38%) and mid-IR emission (43%) from 8 to 160 {mu}m, above that expected from an old stellar population. These excesses are consistent with ongoing star formation activity in the BCG, star formation that appears to be enabled by the presence of high-density, X-ray-emitting intergalactic gas in the core of the cluster of galaxies. This hot, X-ray-emitting gas may provide the enhanced ambient pressure and some of the fuel to trigger star formation. This result is consistent with previous works that showed that BCGs in clusters with low central gas entropies host H{alpha} emission-line nebulae and radio sources, while clusters with high central gas entropy exhibit none of these features. GALEX UV and Spitzer mid-IR measurements combined provide a complete picture of unobscured and obscured star formation occurring in these systems. We present IR and UV photometry and estimated equivalent continuous SFRs for a sample of BCGs.

79 ASTRONOMY AND ASTROPHYSICS↗

The Athena Mars Rover Science Payload

The Mars Surveyor missions that will be launched in April of 2001 will include a highly capable rover that is a successor to the Mars Pathfinder mission's Sojourner rover. The design goals for this rover are a total traverse distance of at least 10 km and a total lifetime of at least one Earth year. The rover's job will be to explore a site in Mars' ancient terrain, searching for materials likely to preserve a record of ancient martian water, climate, and possibly biology. The rover will collect rock and soil samples, and will store them for return to Earth by a subsequent Mars Surveyor mission in 2005. The Athena Mars rover science payload is the suite of scientific instruments and sample collection tools that will be used to perform this job. The specific science objectives that NASA has identified for the '01 rover payload are to: (1) Provide color stereo imaging of martian surface environments, and remotely-sensed point discrimination of mineralogical composition. (2) Determine the elemental and mineralogical composition of martian surface materials. (3) Determine the fine-scale textural properties of these materials. (4) Collect and store samples. The Athena payload has been designed to meet these objectives. The focus of the design is on field operations: making sure the rover can locate, characterize, and collect scientifically important samples in a dusty, dirty, real-world environment. The topography, morphology, and mineralogy of the scene around the rover will be revealed by Pancam/Mini-TES, an integrated imager and IR spectrometer. Pancam views the surface around the rover in stereo and color. It uses two high-resolution cameras that are identical in most respects to the rover's navigation cameras. The detectors are low-power, low-mass active pixel sensors with on-chip 12-bit analog-to-digital conversion. Filters provide 8-12 color spectral bandpasses over the spectral region from 0.4 to 1.1 micron Narrow-angle optics provide an angular resolution of 0.28 mrad/pixel, nearly a factor of four higher than that of the Mars Pathfinder and Mars Surveyor '98 cameras. Image compression will be performed using a wavelet compression algorithm. The Mini-Thermal Emission Spectrometer (Mini-TES) is a point spectrometer operating in -the thermal IR. It produces high spectral resolution (5 /cm) image cubes with a wavelength range of 5-40 gm, a nominal signal/noise ratio of 500:1, and a maximum angular resolution of 7 mrad (7 cm at a distance of 10 in). The wavelength region over which it operates samples the diagnostic fundamental absorption features of rockforming minerals, and also provides some capability to see through dust coatings that could tend to obscure spectral features. The mineralogical information that Mini-TES provides will be used to select from a distance the rocks and soils that will be investigated in more detail and ultimately sampled. Mini-TES is derived from the MO/MGS TES instrument, but is significantly smaller and simpler. The instrument uses an 8-cm Cassegrain telescope, a Michelson interferometer, and uncooled pyroelectric detectors. Along with its mineralogical capabilities, Mini-TES can provide information on the thermophysical properties of rocks and soils. Viewing upward, it can also provide temperature profiles through the martian atmospheric boundary layer. Elemental and Mineralogical Composition: Once promising samples have been identified from a distance using Pancam/Mini-TES, they will be studied in detail using up to three compositional sensors that can be placed directly against them by an Instrument Arm. The two compositional sensors, presently on the payload are an Alpha-Proton-X-Ray Spectrometer (APXS), and a Mossbauer Spectrometer. The APXS is derived closely from the instrument that flew on Mars Pathfinder. Radioactive alpha sources and three detection modes (alpha, proton, and x-ray) provide elemental abundances of rocks and soils to complement and constrain mineralogical data. The Athena APXS will have a revised mechanical design that will cut down significantly on backscattering of alpha particles from martian atmospheric carbon. It will also include a target of known elemental composition that will be used for calibration purposes. The Athena Mossbauer Spectrometer is a diagnostic instrument for the mineralogy and oxidation state of Fe-bearing phases, which are particularly important on Mars. The instrument measures the resonant absorption of gamma rays produced by a Co-57 source to determine splitting of nuclear energy levels in Fe atoms that is related to the electronic environment surrounding them. It has been under development for space flight for many years at the Technical University of Darmstadt. The Mossbauer Spectrometer (and the other arm instruments) will be able to view a small permanent magnet array that will attract magnetic particles in the martian soil. The payload may also include a Raman Spectrometer. If included, the Raman Spectrometer will provide precise identification of major and minor mineral phases. It requires no sample preparation, and is also sensitive to organics. Fine-Scale Texture: The Instrument Arm a also carries a Microscopic Imager that will obtain high-resolution monochromatic images of the same materials for which compositional data will be obtained. Its spatial resolution is 20 micron/pixel over a 1 cm depth of field, and 40 micron/pixel over a 1-cm depth of field. Like Pancam, it uses the same active pixel sensor detectors and electronics as the rover's navigation cameras. The Instrument Arm is a three degree-of-freedom arm that uses designs and components from the Mars Pathfinder and Mars Surveyor '98 projects. Its primary function is instrument positioning. Along with the instruments noted above, it also carries a brush that can be used to remove dust and other loose coatings from rocks. Sample Collection and Storage: Martian rock and soil samples will be collected using a low-power rotary coring drill called the Mini-Corer. An important characteristic of this device is that it can obtain intact samples of rock from up to 5 cm within strong boulders and bedrock, Nominal core dimensions are 8xl7 mm. The Mini-Corer drills a core to the commanded depth in a rock, shears it off, retains it, and extracts it. It can also acquire samples of loose soil, using soil sample cups that are pressed downward into loose material. The Mini-Corer can drill at angles from vertical to 45' off vertical. It has six interchangeable bits for long life. Mechanical damage to the sample during drilling is minimal, and heating is negligible. After acquisition, the sample may be viewed by the arm instruments, and/or placed in one of 104 compartments in the Sample Container. A subset of the acquired samples may be replaced with other samples obtained later if desired. The Sample Container has no moving parts, and is mounted external to the rover for easy removal by the Mars Surveyor 2005 flight system. Operation of the rover will make extensive use of automated onboard navigation and hazard avoidance capabilities. Otherwise, use of onboard autonomy is minimal. Data downlink capability is about 40 Mbit/sol, and the use of the Mars Surveyor '01 orbiter for data relay imposes a limit of at most two command cycles per sol. Because of the significant amount of time available between command cycles, all payload elements will be operated sequentially, rather than in parallel.; this approach also significantly simplifies operations and minimizes peak power usage. The landing site for the '01 rover has not been selected yet. Site selection will make as full use as possible of Mars Global Surveyor data, and will involve substantial input from the broad Mars science community. Summary: The following table describes the mass, power, providers, and key scientific objectives of all the major elements of the Athena payload. Additional Athena payload information may be found at: http://astrosun.tn.cornell.edu/athena/index.html. Additional information contained in the original.

Squyes, S. W.↗

Instrumentation Working Group Summary

The Instrumentation Working Group compiled a summary of measurement techniques applicable to gas turbine engine aerosol precursors and particulates. An assessment was made of the limits, accuracy, applicability, and technology readiness of the various techniques. Despite advances made in emissions characterization of aircraft engines, uncertainties still exist in the mechanisms by which aerosols and particulates are produced in the near-field engine exhaust. To adequately assess current understanding of the formation of sulfuric acid aerosols in the exhaust plumes of gas turbine engines, measurements are required to determine the degree and importance of sulfur oxidation in the turbine and at the engine exit. Ideally, concentrations of all sulfur species would be acquired, with emphasis on SO2 and SO3. Numerous options exist for extractive and non-extractive measurement of SO2 at the engine exit, most of which are well developed. SO2 measurements should be performed first to place an upper bound on the percentage of SO2 oxidation. If extractive and non-extractive techniques indicate that a large amount of the fuel sulfur is not detected as SO2, then efforts are needed to improve techniques for SO3 measurements. Additional work will be required to account for the fuel sulfur in the engine exhaust. Chemical Ionization Mass Spectrometry (CI-MS) measurements need to be pursued, although a careful assessment needs to be made of the sampling line impact on the extracted sample composition. Efforts should also be placed on implementing non-intrusive techniques and extending their capabilities by maximizing exhaust coverage for line-of-sight measurements, as well as development of 2-D techniques, where feasible. Recommendations were made to continue engine exit and combustor measurements of particulates. Particulate measurements should include particle size distribution, mass fraction, hydration properties, and volatile fraction. However, methods to ensure that unaltered samples are obtained need to be developed. Particulate speciation was also assigned a high priority for quantifying the fractions of carbon soot, PAH, refractory materials, metals, sulfates, and nitrates. High priority was also placed on performing a comparison of particle sizing instruments. Concern was expressed by the workshop attendees who routinely make particulate measurements about the variation in number density measured during in-flight tests by different instruments. In some cases, measurements performed by different groups of researchers during the same flight tests showed an order of magnitude variation. Second priority was assigned to measuring concentrations of odd hydrogen and oxidizing species. Since OH, HO2, H2O2, and O are extremely reactive, non-extractive measurements are recommended. A combination of absorption and fluorescence is anticipated to be effective for OH measurements in the combustor and at the engine exit. Extractive measurements of HO2 have been made in the stratosphere, where the ambient level of OH is relatively low. Use of techniques that convert HO2 to OH for combustor and engine exit measurements needs to be evaluated, since the ratio of HO2/OH may be 1% or less at both the combustor and engine exit. CI-MS might be a viable option for H2O2, subject to sampling line conversion issues. However, H2O2 is a low priority oxidizing species in the combustor and at the engine exit. Two candidates for atomic oxygen measurements are Resonance Enhanced Multi-Photon Ionization (REMPI) and Laser-Induced Fluorescence (LIF). Particulate measurement by simultaneous extractive and non-extractive techniques was given equal priority to the oxidizer measurements. Concern was expressed over the ability of typical ground test sampling lines to deliver an unaltered sample to a remotely located instrument. It was suggested that the sampling probe and line losses be checked out by attempting measurements using an optical or non-extractive technique immediately upstream of the sampling probe. This is a possible application for Laser Induced Incandescence (LII) as a check on the volume fraction of soot. Optical measurements of size distribution are not well developed for ultrafine particles less than about 20 nm in diameter, so a non-extractive technique for particulate size distribution cannot be recommended without further development. Carbon dioxide measurements need to be made to complement other extractive measurement techniques. CO2 measurements enable conversion of other species concentrations to emission indices. Carbon monoxide, which acts as a sink for oxidizing species, should be measured using non-extractive techniques. CO can be rapidly converted to CO2 in extractive probes, and a comparison between extractive and non-extractive measurements should be performed. Development of non-extractive techniques would help to assess the degree of CO conversion, and might be needed to improve the concentration measurement accuracy. Measurements of NO(x) will continue to be critical due to the role of NO and NO2 in atmospheric chemistry, and their influence on atmospheric ozone. Time-resolved measurements of temperature, velocity, and species concentrations were included on the list of desired measurement. Thermocouples are typically adequate for engine exit measurements. PIV and LDV are well established for obtaining velocity profiles. The techniques are listed in the accompanying table; are divided into extractive and non-extractive techniques. Efforts were made to include a measurement uncertainty for each technique. An assessment of the technology readiness was included.

Zaller, Michelle↗

Adsorption of the Lighter Homologs of Element 104 and Element 105 on DGA Resin from Various Mineral Acids

The goal of studying transactinide elements is to further understand the fundamental principles that govern the periodic table. The current periodic table arrangement allows for the prediction of the chemical behavior of elements. The correct position of a transactinide element can be assessed by investigating its chemical behavior and comparing it to that of the homologs and pseudo-homologs of a transactinide element. Homologs of a transactinide element are the elements in the same group of the periodic table as the transactinide. A pseudo-homolog of a transactinide element is an element with a similar main oxidation state and similar ionic radius to the transactinide element. For example, the homologs of rutherfordium, Rf, are titanium, zirconium and hafnium (Ti, Zr and Hf); the pseudo homologs of Rf are thorium, Th, and plutonium, Pu. Understanding the chemical behavior of a transactinide element compared to its homologs and pseudo-homologs also allows for the assessment of the role of relativistic effects. Relativistic effects occur when the velocity of the s orbital electrons closest to the nucleus approaches the speed of light. These electrons approach the speed of light because they have no orbital momentum. This causes two effects, first there is in a decrease in Bohr radius of the inner electronic orbitals because of this there is an increase in particle mass. A contraction of outer s and p orbitals is also seen. The contraction of these orbitals results in an energy destabilization of the outer most shell, in the case of transactinides this would be the 5f and 6d orbitals. The outer most d shell and all f shells can also experience a radial expansion due to these orbitals being screened from the effective nuclear charge. Another relativistic effect is the 'spin-orbit splitting' for p, d and f orbitals into j = 1 {+-} 1/2 states. Where j is the total angular momentum vector and 1 is angular quantum number. All of these effects have the same order of magnitude and increase roughly according to Z. This feature is what makes studying the heavy elements so interesting because the chemical properties of transactinide elements should strongly exhibit these effects. For this work the terms heavy element and transactinide elements will be used interchangeably and are defined as elements with an atomic number greater than 103, Z > 103. In order to study the transactinide elements they must be isolated once they have been produced and transported to a chemistry apparatus. The transactinide elements are produced either via 'hot' or 'cold' fusion reactions. 'Hot' fusion reactions result in excitation energies of the compound nucleus of 40-50 MeV and occur when an actinide target nuclei fuse with a projectile with A < 40, where A is the atomic mass number. 'Cold' fusion results in excitation energies of 10-15 MeV. Cold fusion conditions tend to occur when a target of a spherical nuclei (Pb or Bi) is bombarded with a heavy projectile (A > 40). Hot fusion generally leads to neutron rich isotopes and cold fusion tends to produce a compound nucleus that emits 1-2 neutrons upon de-excitation. If a sufficiently thin target is employed, then the products of the nuclear reaction will recoil out of the target and can either be transported to the chemistry setup, e.g. using a gas jet, or trapped by implementing them on a catcher. An example for a catcher setup using a copper block as a catcher is described here. The copper block is placed behind the target during the irradiation and all nuclei recoiling from the target position will implant themselves in the block. The copper block is subsequently dismounted and sputter cleaned. It is then shaved with a micro-lathe. The 7-10 {micro}m copper shavings are then subjected to chemical separation. The copper is dissolved in aqua regia. Lanthanum carrier is added to the aqua regia to precipitate tri-, tetra- and penta- valent cations when ammonium hydroxide is added. The precipitate is then washed and converted to the nitrate form. This solution is then added onto a cation exchange column, the eluent is deposited and dried on a polypropylene film and then counted on solid state detectors. There are several challenges when studying the chemical behavior of transactinide elements. The first challenge is the low production rate of transactinides. Transactinides are produced on an atom-at-a-time basis, meaning that only one atom is ever available for chemical study. Because of this the chemical system being used must be selective for only one chemical state. The second challenge in transactinide chemistry is the short half-lives of the elements. Half-lives of the transactinides range from nanoseconds to a few hours. This leads to the need for fast chemistry. Another challenge is the need for a high degree of separation from interfering radionuclides so that the event with the transactinide element can be detected.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗