Search NASA⌕ Search

SEARCH · Search NASA

Results for “temporal resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

A Japanese plan: Large radio heliograph in the solar max no. 22

An outline as of February, 1986 is briefly described of a Japanese plan to construct a large radio heliograph in the next solar maximum. The principal performance specifications of the heliograph are 10 arsec by 10 arcsec x SEC(Zenith Distance) spatial resolution, 1 arc degree by 1 arc degree field of view, 1-sec temporal resolution, and six hour coverage of observing time. It will be operated at 17 GHz with possible other frequency of 35GHz.

Enome, Shinzo↗

EUNIS: An Extreme-Ultraviolet Normal-Incidence Spectrometer

GSFC is in the process of assembling an Extreme-Ultraviolet Normal-Incidence Spectrometer called EUNIS, to be flown as a sounding rocket payload. This instrument builds on the many technical innovations pioneered by our highly successful SERTS experiment over its past ten flights. The new design will have somewhat improved spatial and spectral resolutions, as well as 100 times greater sensitivity, permitting EUV spectroscopy with a temporal resolution near 1-second for the first time ever. To achieve such high time cadence, a novel Active-Pixel-Sensor detector is being developed as a key component of our design. The high sensitivity of EUNIS will allow entirely new studies of transient coronal phenomena, such as the rapid loop dynamics seen by TRACE, and searches for non-thermal motions indicative of magnetic reconnection or wave heating. The increased sensitivity will also permit useful EUV spectra at heights of 2-3-R$ \odot$ above the limb, where the transition between the static corona and the solar wind might occur. In addition, the new design features two independent optical systems, more than doubling the spectral bandwidth covered on each flight. Its 300-370\AA\ bandpass includes He-II 304\AA\ and strong lines from Fe-XI-XVI, extending the current SERTS range of 300-355\AA\ to further improve our ongoing series of calibration under-flights for SOHO/CDS and EIT. The second bandpass of 170-230\AA\ has a sequence of very strong Fe-IX-XIV lines, and will allow under-flight support for two more channels on SOHO/EIT, two channels on TRACE, one on Solar-B/EIS, and all four channels on the STEREO/EUVI instrument. First flight of the new EUNIS payload is scheduled for 2002 October.

Thomas, Roger J.↗

Intercomparison of GOES-8 Imager and Sounder Land Surface Temperature Retrievals

Recent studies at the Global Hydrology and Climate Center (GHCC) have shown that the assimilation of land skin temperature (LST) tendencies into a mesoscale model can significantly improve short term forecasts of near surface temperature and moisture. The high spatial and temporal resolution of GOES derived land surface products provide valuable information about the spatial and temporal variability of the land surface forcing simulated in the model. In the GHCC studies LST was derived using a split window technique requiring at least two longwave infrared window channels and thus, utilized the 11 and 12 micron channels found on the GOES-8 Imager with a nadir spatial resolution of 4km. However, beginning with the launch of GOES-M (scheduled for mid 2001 ) and subsequent satellites the 12 micron channel will be removed from the Imager leaving only one longwave window channel. The GOES Sounder will continue to have more than one longwave infrared window channel (including a 12 micron channel) but, with a spatial resolution of 10 km nadir. LST retrievals from the newer GOES satellites will thus be derived from Sounder measurements at a reduced spatial resolution. This paper intercompares the LST retrievals from the GOES-8 Imager and Sounder. The effects on the LST retrievals due to the Sounder's reduced resolution from that of the Imager and its different longwave infrared channel characteristics are examined. The effects of transitioning from Imager to Sounder LST products on the results from model assimilation of these products are also examined.

Suggs, Ronnie J.↗

Time-resolved and multiple-angle Thomson scattering on gas-puff Z-Pinch plasmas at pinch time

A 526.5 nm Thomson scattering diagnostic laser enables probing of the plasma conditions of neon gas-puff z-pinch implosions with temporal resolution. Splitting the laser into two 2.5 J pulses, both 2.3 ns in duration and separated by 4 ns, allows observation of sub-nanosecond time-resolved spectra for a total time of 7 ns. Collection optics were set at 90° and 30° to the laser, observing the same on-axis scattering volume with a radial extent of 0.4 mm. The spectra from both angles were collected by using the same streak camera, using a coupling system that allowed us to obtain temporal, spectral, and angular resolution in the same image. By comparing the ion-acoustic spectra from the two angles, we determined electron temperature and a range of possible electron densities. Measurements made in the 1-3 ns period before pinch time show best fit (determined by a least-squares method) electron densities of around 2 × 10 19 cm -3 , increasing to 1.5 × 10 20 cm -3 in the 3 ns following the start of the x-ray burst (t = 0 ns) from the pinch. The electron temperature increases from 300 eV to 500 eV at t = 0 ns before decreasing to below 300 eV after pinch time. With the present parameters (probe beam, collection angles, and electron temperature and density), this diagnostic method is too insensitive to electron density to provide more than a constraint on that parameter. Plasma regimes in which this technique could determine electron density with some precision are calculated.

47 OTHER INSTRUMENTATION↗

A grazing incidence x-ray streak camera for ultrafast, single-shot measurements

An ultrafast x-ray streak camera has been realized using a grazing incidence reflection photocathode. X-rays are incident on a gold photocathode at a grazing angle of 20 degree and photoemitted electrons are focused by a large aperture magnetic solenoid lens. The streak camera has high quantum efficiency, 600fs temporal resolution, and 6mm imaging length in the spectral direction. Its single shot capability eliminates temporal smearing due to sweep jitter, and allows recording of the ultrafast dynamics of samples that undergo non-reversible changes.

36 MATERIALS SCIENCE↗

Combining eddy-covariance and chamber measurements to determine the methane budget from a small, heterogeneous urban floodplain wetland park

Methane (CH 4 ) emissions and carbon uptake in temperate freshwater wetlands act in opposing directions in the context of global radiative forcing. Large uncertainties exist for the rates of CH 4 emissions making it difficult to determine the extent that CH 4 emissions counteract the carbon sequestration of wetlands. Urban temperate wetlands are typically small and feature highly heterogeneous land cover, posing an additional challenge to determining their CH 4 budget. The data analysis approach we introduce here combines two different CH 4 flux measurement techniques to overcome scale and heterogeneity problems and determine the overall CH 4 budget of a small, heterogeneous, urban wetland landscape. Temporally intermittent point measurements from non-steady-state chambers provided information about patch-level heterogeneity of fluxes, while continuous, high temporal resolution flux measurements using the eddy-covariance (EC) technique provided information about the temporal dynamics of the fluxes. Patch-level scaling parameterization was developed from the chamber data to scale eddy covariance data to a ‘fixed-frame’, which corrects for variability in the spatial coverage of the eddy covariance observation footprint at any single point in time. Finally, by combining two measurement techniques at different scales, we addressed shortcomings of both techniques with respect to heterogeneous wetland sites.

03 NATURAL GAS↗

Multimodal super-resolution: discovering hidden physics and its application to fusion plasmas

Understanding complex physical systems often requires integrating data from multiple diagnostics, each with limited resolution or coverage. We present a machine learning framework that reconstructs synthetic high-temporal-resolution data for a target diagnostic using information from other diagnostics, without direct target measurements during the inference. This multimodal super-resolution technique improves diagnostic robustness and enables monitoring even in case of measurement failures or degradation. Applied to fusion plasmas, our method targets edge-localized modes (ELMs), which can damage plasma-facing materials. By reconstructing super-resolution Thomson Scattering data from complementary diagnostics, we uncover fine-scale plasma dynamics and validate the role of resonant magnetic perturbations (RMPs) in ELM suppression through magnetic island formation. The approach provides new observation supporting the plasma profile flattening due to these islands. Our results demonstrate the framework’s ability to generate high-fidelity synthetic diagnostics, offering a powerful tool for ELM control development in future reactors like ITER. The approach is broadly transferable to other domains facing sparse, incomplete, or degraded diagnostic data, opening new avenues for discovery.

Jalalvand, Azarakhsh [Princeton Univ., NJ (United ↗

SCEMA: a high channel density electronics module for fast waveform capture

The development of fast, highly pixelated photodetectors with single-photon sensitivity has the potential to enable a variety of new radiation detection concepts. Systems that desire to employ these detectors without loss of information demand waveform digitization with high sampling rates. Switched capacitor arrays provide a low-cost, low-power, compact solution to fast readout with high channel density. The Sandia Laboratories Compact Electronics for Modular Acquisition (SCEMA) was developed to meet these demands. A single module employs two domino ring sampling switched capacitor arrays (DRS4) [1] to provide 16 channels of up to 5 GS/s waveform digitization. This paper presents an overview of the board design and function. Calibration procedures for the module are discussed. Lastly, temporal resolution tests are presented demonstrating the module's viability as readout for high fidelity temporal measurements of single photons in suitable photodetectors.

47 OTHER INSTRUMENTATION↗

Design and test of a High-Resolution EUV Spectroheliometer

The HiRES High-Resolution EUV Spectroheliometer is a sounding rocket instrument yielding very high spatial, spectral, and temporal resolution images of the solar outer atmosphere, on the basis of a 45-cm Gregorian telescope feeding a normal-incidence stigmatic EUV spectrometer with imaging multianode microchannel-array detector system, as well as an IR spectrometer with imaging CCD detector system. Attention is given to the expected performance of this system, including the effects of vibrational misalignments due to the sounding rocket flight environment.

Berger, Thomas E.↗

Ground Based Operational Testing Of Holographic Scanning Lidars : The HOLO Experiments

Two aerosol backscatter lidar measurement campaigns were conducted using two holographic scanning lidars and one zenith staring lidar for the purposes of reliability testing under field conditions three new lidar systems and to develop new scanning measurement techniques and applications. The first campaign took place near the campus of Utah State University in Logan Utah in March of 1999 and is called HOLO-1. HOLO-2 was conducted in June of 1999 on the campus of Saint Anselm College, near the city of Manchester, New Hampshire. Each campaign covered a period of approximately one week of nearly continuous observation of cloud and aerosol backscatter in the visible and near infrared by lidar, and wide field visible sky images by video camera in the daytime. The scanning capability coupled with a high rep-rate, high average power laser enables both high spatial and high temporal resolution observations that Particularly intriguing is the possibility of deriving atmospheric wind profiles from temporal analysis of aerosol backscatter spatial structure obtained by conical scan without the use of Doppler techniques.

Schwemmer, Geary K.↗

Fluorescence Imaging of Underexpanded Jets and Comparison with CFD

An experimental study of underexpanded and highly underexpanded axisymmetric nitrogen free jets seeded with 0.5% nitric oxide (NO) and issuing from a sonic orifice was conducted at NASA Langley Research Center. Reynolds numbers based on nozzle exit conditions ranged from 770 to 35,700, and nozzle exit-to-ambient jet pressure ratios ranged from 2 to 35. These flows were non-intrusively visualized with a spatial resolution of approximately 0.14 mm x 0.14 mm x 1 mm thick and a temporal resolution of 1 s using planar laser-induced fluorescence (PLIF) of NO, with the laser tuned to the strongly-fluorescing UV absorption bands of the Q1 band head near 226.256 nm. Three laminar cases were selected for comparison with computational fluid dynamics (CFD). The cases were run using GASP (General Aerodynamic Simulation Program) Version 4. Comparisons of the fundamental wavelength of the jet flow showed good agreement between CFD and experiment for all three test cases, while comparisons of Mach disk location and Mach disk diameter showed good agreement at lower jet pressure ratios, with a tendency to slightly underpredict these parameters with increasing jet pressure ratio.

Wilkes, Jennifer A.↗

Great Lakes Hyperspectral Water Quality Instrument Suite for Airborne Monitoring of Algal Blooms

NASA Glenn Research Center and NOAA Great Lakes Environmental Research Lab are collaborating to utilize an airborne hyperspectral imaging sensor suite to monitor Harmful Algal Blooms (HABs) in the western basin of Lake Erie. The HABs are very dynamic events as they form, spread and then disappear within a 4 to 8 week time period in late summer. They are a concern for human health, fish and wildlife because they can contain blue green toxic algae. Because of this toxicity there is a need for the blooms to be continually monitored. This situation is well suited for aircraft based monitoring because the blooms are a very dynamic event and they can spread over a large area. High resolution satellite data is not suitable by itself because it will not give the temporal resolution due to the infrequent overpasses of the quickly changing blooms. A custom designed hyperspectral imager and a point spectrometer mounted on aT 34 aircraft have been used to obtain data on an algal bloom that formed in the western basin of Lake Erie during September 2006. The sensor suite and operations will be described and preliminary hyperspectral data of this event will be presented

Lekki, John↗

Domain-wall oscillations studies by time-resolved soft x-ray mircorscopy

Fast magnetization dynamics in the micro- and nanometer regime are an interesting field of research. On these length scales magnetic structures can be designed to contain a single vortex or a single domain wall. Both size and speed of these patterns are of great interest in todays research for prospective non-volatile data storage devices. Especially the possibility to move domain-walls by spin-polarized current gained a lot of interest. Magnetic configurations can be imaged by soft X-ray magnetic microscopy with a spatial resolution down to 15 nm. By a stroboscopic pump and probe measurement scheme a temporal resolution below 100 ps is achieved. This provides the opportunity to directly image changes in magnetic domains and domain-wall motion. We image oscillations of a single domain wall in a confining potential in time steps of 200 ps by time resolved X-ray microscopy at the full-field soft X-ray transmission microscope at the Advanced Light Source in Berkeley (beamline 6.1.2). Domain walls are prepared in permalloy nanostructures with a restoring potential. The oscillation of a 180{sup o} domain wall is triggered by nanosecond current pulses. The spin-polarized current and the accompanying Oersted field can contribute to the motion of the wall. By analysis of the distinct domain-wall dynamics the dominant contribution is determined. In our geometry the motion of the wall is determined by the Oersted field although the spin-polarized current directly flows through the ferromagnetic structure. An analytical model of a rigid particle precisely describes the domain-wall motion. Oscillations are studied for different pulse length and amplitudes. From the observed oscillations we extract the driving force, the confining potential, and the domain-wall mass. Nonharmonic terms determine the motion of the wall. The influence of the nonharmonic potential is studied by looking at various phase spaces of the domain-wall motion.

36 MATERIALS SCIENCE↗

Breaking the Time Barrier in Kelvin Probe Force Microscopy: Fast Free Force Reconstruction Using the G-Mode Platform

The atomic force microscope (AFM) offers unparalleled insight into structure and material functionality across nanometer length scales. However, the spatial resolution afforded by the AFM tip is counterpoised by slow detection speeds compared to other common microscopy techniques (e.g. optical, scanning electron microscopy etc.). In this work, we develop an AFM imaging approach allowing ultrafast reconstruction of the tip-sample forces having ~2 orders of magnitude higher time resolution than standard detection methods. Fast free force recovery (F3R) overcomes the widely-viewed temporal bottleneck in AFM, i.e. the mechanical bandwidth of the cantilever, enabling time-resolved imaging at sub-bandwidth speeds. We demonstrate quantitative recovery of electrostatic forces with ~10 µs temporal resolution, free from cantilever ring-down effects. We further apply the F3R method to Kelvin probe force microscopy (KPFM) measurements. F3R-KPFM is an open loop imaging approach (i.e. no bias feedback), allowing ultrafast surface potential measurements (e.g. < 20 µs) to be performed at regular KPFM scan speeds. F3R-KPFM is demonstrated for exploration of ion migration in organometallic halide perovskites materials and shown to allow spatio-temporal imaging of positively charged ion migration under applied electric field, as well as subsequent formation of accumulated charges at the perovskite/electrode interface. In this work we demonstrate quantitative F3R-KPFM measurements – however, we fully expect the F3R approach to be valid for all modes of non-contact AFM operation, including non-invasive probing of ultrafast electrical and magnetic dynamics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Mapping the Daily Progression of Large Wildland Fires Using MODIS Active Fire Data

High temporal resolution information on burned area is a prerequisite for incorporating bottom-up estimates of wildland fire emissions in regional air transport models and for improving models of fire behavior. We used the Moderate Resolution Imaging Spectroradiometer (MODIS) active fire product (MO(Y)D14) as input to a kriging interpolation to derive continuous maps of the evolution of nine large wildland fires. For each fire, local input parameters for the kriging model were defined using variogram analysis. The accuracy of the kriging model was assessed using high resolution daily fire perimeter data available from the U.S. Forest Service. We also assessed the temporal reporting accuracy of the MODIS burned area products (MCD45A1 and MCD64A1). Averaged over the nine fires, the kriging method correctly mapped 73% of the pixels within the accuracy of a single day, compared to 33% for MCD45A1 and 53% for MCD64A1.

Aqua↗

Multi-Sensor Integration of Vegetation Index Products for Long-Term Monitoring of Vegetation Dynamics: A Case Study from MODIS to VIIRS

Spectral vegetation index (VI) time series data from moderate resolution sensors, such as Earth Observing System (EOS) Moderate Resolution Imaging Spectroradiometer (MODIS), have widely been used to identify "hot spot" areas of vegetation changes and to characterize long-term trends of vegetation changes. The Visible Infrared Imaging Radiometer Suite (VIIRS) sensor series of the Joint Polar Satellite System (JPSS) program is slated to continue the highly calibrated data stream initiated with MODIS. The first VIIRS sensor has operationally been acquiring Earth-reflected radiation since March 2012. The second VIIRS sensor (NOAA-20) was launched in November 2017, which is to continue the measurements made by the first VIIRS sensor. In this study, we examined an integrated use of MODIS and VIIRS VI time series data on capturing vegetation dynamics in the Asia-Pacific region using their overlapped period of observations (2013-2017). Three VIs, the "top-of-canopy (TOC)" normalized difference vegetation index (NDVI), TOC enhanced vegetation index (EVI), and TOC two-band enhanced vegetation index (EVI2), were investigated. For all the three VIs, VIIRS VIs were systematically higher than the MODIS counterparts due mainly to their spectral bandpass differences. However, both VIIRS and MODIS VIs showed the comparable spatial patterns in their temporal variations. Empirical spectral corrections allowed to merge the two data streams, which slightly improved the temporal resolution of the VI temporal profiles. These results suggest the suitability of VIIRS data to extend and merge into the MODIS VI record for long-term vegetation dynamics studies.

MODIS↗

UAV-based multispectral time-series imagery of biomass sorghum - 2019

UAV-based high-resolution multispectral time-series orthophotos utilized to understand the relation between growth dynamics, imagery temporal resolution, and end-of-season biomass productivity of biomass sorghum as bioenergy crop. Sensor utilized is a RedEdge Micasense flown at 40 meters above ground level at the Energy Farm- UIUC in 2019.

Bioenergy crops↗

Variability of Upper-Tropospheric Precipitable from Satellite and Model Reanalysis Datasets

Numerous datasets have been used to quantify water vapor and its variability in the upper-troposphere from satellite and model reanalysis data. These investigations have shown some usefulness in monitoring seasonal and inter-annual variations in moisture either globally, with polar orbiting satellite data or global model output analysis, or regionally, with the higher spatial and temporal resolution geostationary measurements. The datasets are not without limitations, however, due to coverage or limited temporal sampling, and may also contain bias in their representation of moisture processes. The research presented in this conference paper inter-compares the NVAP, NCEP/NCAR and DAO reanalysis models, and GOES satellite measurements of upper-tropospheric,precipitable water for the period from 1988-1994. This period captures several dramatic swings in climate events associated with ENSO events. The data are evaluated for temporal and spatial continuity, inter-compared to assess reliability and potential bias, and analyzed in light of expected trends due to changes in precipitation and synoptic-scale weather features. This work is the follow-on to previous research which evaluated total precipitable water over the same period. The relationship between total and upper-level precipitable water in the datasets will be discussed as well.

Jedlovec, Gary J.↗