Search NASA⌕ Search

SEARCH · Search NASA

Results for “test well”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

Video Based Sensor for Tracking 3-Dimensional Targets

Video-Based Sensor for Tracking 3-Dimensional Targets The National Aeronautics and Space Administration's (NASAs) Marshall Space Flight Center (MSFC) has been developing and testing video-based sensors for automated spacecraft guidance for several years, and the next generation of video sensor will have tracking rates up to 100 Hz and will be able to track multiple reflectors and targets. The Video Guidance Sensor (VGS) developed over the past several years has performed well in testing and met the objective of being used as the terminal guidance sensor for an automated rendezvous and capture system. The first VGS was successfully tested in closed-loop 3-degree-of-freedom (3- DOF) tests in 1989 and then in 6-DOF open-loop tests in 1992 and closed-loop tests in 1993-4. Development and testing continued, and in 1995 approval was given to test the VGS in an experiment on the Space Shuttle. The VGS flew in 1997 and in 1998, performing well for both flights. During the development and testing before, during, and after the flight experiments, numerous areas for improvement were found. The VGS was developed with a sensor head and an electronics box, connected by cables. The VGS was used in conjunction with a target that had wavelength-filtered retro-reflectors in a specific pattern, The sensor head contained the laser diodes, video camera, and heaters and coolers. The electronics box contained a frame grabber, image processor, the electronics to control the components in the sensor head, the communications electronics, and the power supply. The system works by sequentially firing two different wavelengths of laser diodes at the target and processing the two images. Since the target only reflects one wavelength, it shows up well in one image and not at all in the other. Because the target's dimensions are known, the relative positions and attitudes of the target and the sensor can be computed from the spots reflected from the target. The system was designed to work from I meter out to I 10 meters. The VGS was mounted on the Space Shuttle while its target was mounted on the Spartan free-flyer carried on the same Shuttle flight. The VGS tracked the Spartan at ranges up to 170m, and the VGS range data very closely matched the range data from the Hand-Held Laser- Rangefinder used by the astronauts on board the Shuttle. While the VGS was designed primarily as a terminal guidance sensor for an automated spacecraft, it could be applied to other uses. It could be used as an alignment aid for an operator of a remote system (giving position and attitude feedback data, as well as a camera view of the target), as a feedback system for a robotic arm, or for automated vehicle guidance. The next generation VGS, with its higher tracking rates, smaller size, and lower power could be used in more places than the original VGS, and by using LED's instead of laser diodes, the system would be eye-safe at any range. Other possible uses include tracking 3-dimensional objects with retro-reflectors mounted at various locations or motion analysis by placing several retro-reflectors on the moving object and tracking them at high speeds. There are few sensors capable of performing tasks similar to those the VGS can perform, and the next generation VGS will be even more capable than the original. Some of this work is previously presented in the papers.

Howard, R. T.↗

Pathfinder Technology Demonstrator: GlobalStar Testing and Results

The communications subsystem of a spacecraft is typically a SWaP (size, weight, and power) intensive subsystem in a SWaP constrained environment such as a CubeSat. Use of a satellite-based communication system, such as GlobalStars duplex GSP-1720 radio is a low SWaP potentially game-changing low-cost communication subsystem solution that was evaluated for feasibility for the NASA Pathfinder Technology Demonstrator (PTD) project. The PTD project is a series of 6U CubeSat missions to flight demonstrate and characterize novel small satellite payloads in low Earth orbit. GlobalStar is a low Earth orbit satellite constellation for satellite phone and low-speed data communications, and the GSP-1720 is their single board duplex radio most commonly used in satellite phones and shipment tracking devices. The PTD project tested the GSP-1720 to characterize its viability for flight using NASA GEVS (General Environmental Verification Standard) vibration and thermal vacuum levels, as well as testing the uplink-downlink connectivity, data throughput, and file transfer capabilities. This presentation will present the results of the environmental and capability testing of the GSP-1720 performed at NASA Ames Research Center, as well as the viability for CubeSat use in LEO.

satellite communication↗

Measuring and interpreting borehole strainmeter data to improve CO2 storage

Injecting fluids into a well deforms the enveloping rocks in a complex pattern that increases in magnitude and expands outward with time, and measurements of this strain field may be useful for monitoring the injection process. A pair of instruments capable of measuring four components of strain and two components of tilt has been developed. One instrument is designed to be removeable, whereas the other one is grouted in place. The removeable strainmeter provides versatility and lower cost because it can be relocated, whereas the grout-in instrument provides better coupling to the formation, which should improve the strain signal. The new strainmeters have been deployed along with a Gladwin strainmeter at the Avant Field, an oil field north of Tulsa, Oklahoma. Oil and water are being pumped out, and water is being injected in multiple boreholes that intersect the Bartlesville formation at a depth of approximately 500 m at the Avant Field. The strainmeters have been deployed at a depth of 30 m near well 9A, an injection well near the edge of the field. Results from a brief, 4-hr-long injection test into well 9A show that the radial and circumferential strain increase (become tensile) with time during injection, reaching a maximum of several 10s of nanostrain. In another example, data from the Gladwin strainmeter showed the strain field changing with time when an injection well 1 km away was shut-in. This caused the strain along a radial direction to become tensile, while the circumferential strain became compressive. This trend reversed a week later when injection into the well resumed. The major axis of the principle strain aligned with the shut-in well. The observed strain signals are similar to results from poroelastic analyses, and preliminary inverse analyses sugest that strain signals can be used to estimate reservoir characteristics at the Avant Field.

Murdoch, Larry↗

Introduction to Nuclear Propulsion: Lecture 15 - Nuclear Test Operations

The test operation of nuclear power plants, specifically nuclear rockets, bears some interesting similarities to the operation of chemical rocket tests as well as, of course, many differences. A significant feature common to both nuclear and chemical rocket tests is that all the fuel for the entire operation is loaded at the start of the test. As a direct consequence of this fact, the operation of nuclear power plants must be surrounded with adequate safety precautions, as is indeed the case in the operation of chemical rockets, A second direct consequence is that in both types of testing a very thorough and complete checkout is made before starting the test.

TEST METHOD↗

Development of a preprototype vapor compression distillation water recovery subsystem

The activities involved in the design, development, and test of a preprototype vapor compression distillation water recovery subsystem are described. This subsystem, part of a larger regenerative life support evaluation system, is designed to recover usable water from urine, urinal rinse water, and concentrated shower and laundry brine collected from three space vehicle crewmen for a period of 180 days without resupply. Details of preliminary design and testing as well as component developments are included. Trade studies, considerations leading to concept selections, problems encountered, and test data are also presented. The rework of existing hardware, subsystem development including computer programs, assembly verification, and comprehensive baseline test results are discussed.

Johnson, K. L.↗

LOX System Prestart Conditioning on X-34

The X-34 is a reusable launch vehicle that will be carried underneath an airplane to altitude of 35000 feet where it will be launched. It utilizes a single Fastrac 60K rocket engine for propulsion. This engine burns RP-1 and Lox as propellants and has a single shaft Lox and RP-1 turbopump. With these features there are three important requirements that must be met during the prestart thermal conditioning of this engine and feed system. First, the Lox temperature prior to starting the engine must be cold enough to be in the predefined start box at that pressure. Second, the RP-1 in the single shaft turbopump in close proximity to the lox must not freeze significantly where it effects turbopump or engine operation. Third, the chill phase of the prestart countdown has been allocated 700lb of Lox which if exceeded starts to effect mission performance. Extensive testing and analysis has been performed to evaluate the chill characteristics of the Fastrac Engine as well as test facilities and X-34 Lox feed and bleed systems.

Goode, Brian K.↗

Chemical Disposition of Plutonium in Hanford Site Tank Wastes

This report examines the chemical disposition of plutonium (Pu) in Hanford Site tank wastes, by itself and in its observed and potential interactions with the neutron absorbers aluminum (Al), cadmium (Cd), chromium (Cr), iron (Fe), manganese (Mn), nickel (Ni), and sodium (Na). Consideration also is given to the interactions of plutonium with uranium (U). No consideration of the disposition of uranium itself as an element with fissile isotopes is considered except tangentially with respect to its interaction as an absorber for plutonium. The report begins with a brief review of Hanford Site plutonium processes, examining the various means used to recover plutonium from irradiated fuel and from scrap, and also examines the intermediate processing of plutonium to prepare useful chemical forms. The paper provides an overview of Hanford tank defined-waste–type compositions and some calculations of the ratios of plutonium to absorber elements in these waste types and in individual waste analyses. These assessments are based on Hanford tank waste inventory data derived from separately published, expert assessments of tank disposal records, process flowsheets, and chemical/radiochemical analyses. This work also investigates the distribution and expected speciation of plutonium in tank waste solution and solid phases. For the solid phases, both pure plutonium compounds and plutonium interactions with absorber elements are considered. These assessments of plutonium chemistry are based largely on analyses of idealized or simulated tank waste or strongly alkaline systems. The very limited information available on plutonium behavior, disposition, and speciation in genuine tank waste also is discussed. The assessments show that plutonium coprecipitates strongly with chromium, iron, manganese and uranium absorbers. Plutonium’s chemical interactions with aluminum, nickel, and sodium are minimal to non-existent. Credit for neutronic interaction of plutonium with these absorbers occurs only if they are physically proximal in solution or the plutonium present in the solid phase is intimately mixed with compounds or solutions of these absorbers. No information on the potential chemical interaction of plutonium with cadmium was found in the technical literature. Definitive evidence of sorption or adsorption of plutonium onto various solid phases from strongly alkaline media is less clear-cut, perhaps owing to fewer studies and to some well-attributed tests run under conditions exceeding the very low solubility of plutonium. The several studies that are well-founded show that only about half of the plutonium is adsorbed from waste solutions onto sludge solid phases. The organic complexants found in many Hanford tank waste solutions seem to decrease plutonium uptake onto solids. A number of studies show plutonium sorbs effectively onto sodium titanate. Finally, this report presents findings describing the behavior of plutonium vis-à-vis other elements during sludge dissolution in nitric acid based on Hanford tank waste experience gained by lab-scale tests, chemical and radiochemical sample characterization, and full-scale processing in preparation for strontium-90 recovery from PUREX sludges.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Flow and Turbulence Control in a Boundary Layer Wind Tunnel Using Passive Hardware Devices

The Climatic Wind Tunnel (CWT) is a new experimental facility of the Institute of Theoretical and Applied Mechanics (ITAM) in Prague, Czech Republic. It is uniquely able to replicate precipitation and freezing effects on structural models in the climatic test section, and simultaneously perform aerodynamic and aeroelastic tests on structural models in the aerodynamic test section. Extensive measurements are carried out to investigate airflow and turbulence characteristics in the empty aerodynamic test section. Capability to experimentally simulate the atmospheric boundary layer (ABL) is studied using castellated barrier wall, Counihan vortex generators, and surface roughness elements. An individual influence of each of these passive hardware devices is separately tested as well, as they are commonly used combined, and their individual contributions to the ABL model characteristics are not well known. The analysis is based on hot-wire anemometer measurements carried out at various cross sections in the aerodynamic test section of the CWT. Experimental results are reported as mean velocity and turbulence intensity fields for the empty aerodynamic test section without passive hardware devices. Vertical profiles of mean velocity, turbulence intensity, and turbulence length scales, as well as power spectral density of velocity fluctuations, are reported for the ABL small-scale model. The barrier is observed to cause a decrease in flow velocity and an increase in turbulence close to surface. Vortex generators enhance turbulence throughout the entire height range under scope. Increased turbulence and decreased flow velocity are particularly exhibited close to surface due to surface roughness. Influence of each of the studied passive hardware devices on flow and turbulence is quantified in a dimensionless form to allow for separately accounting for their effects.

42 ENGINEERING↗

Natural Gas Drilling near the Underground Nuclear Test Site of Rulison, Colorado - 19571

In 1969, the Project Rulison test was conducted in western Colorado using a nuclear device to stimulate natural gas production by fracturing low-permeability, gas-bearing rock. The presence of radionuclides (specifically tritium) in the produced gas persisted above acceptable levels, and the test was abandoned. Advances in hydrofracturing technology over the past 10-15 years have revolutionized the extraction of hydrocarbons from low-permeability formations, leading to a significant increase of drilling in the Rulison area. Drilling activity nearing the Rulison site has raised concerns that remnant radioactivity might be encountered. The site, now under the care of the US Department of Energy (DOE), is protected by a 16-hectare (40 acre) institutional control boundary (Lot 11) that prohibits drilling or extraction of materials below 1830 meters (6000 feet) within the lot boundary. Drilling within 0.8 kilometer (0.5 mile) of the site requires a hearing before the Colorado Oil and Gas Conservation Commission. DOE recommends that gas developers adopt a conservative, staged drilling approach, allowing gas reserves near the Rulison site to be recovered in a manner that minimizes the likelihood of encountering contamination. The staged approach calls for collecting data from wells away from the site before drilling closer. For instance, the wells 1.2 kilometer (0.75 mile) west of the site did not encounter any unexpected geologic conditions and now have 8 years of production without encountering any detonation-related radionuclides. The next set of wells would be 0.8 kilometer (0.5 mile) west of the site. This sequential method drills first at locations with a low probability of encountering contamination and then moves closer. This process protects public safety while allowing the collection of additional data to confirm that contamination has not migrated beyond the 16-hectare (40-acre) institutional control boundary. The staged drilling approach was simulated with a modeling effort that estimates the current extent of contamination and the potential for production-induced contaminant migration to nearby wells. The model incorporates geologic data from nearby wells and was calibrated to production data from both the reentry well production testing (1970-1971) and the wells 1.2 kilometer (0.75 mile) from the site that began producing in 2010. The geologic data include both sand/shale distribution statistics as well as the tendency of hydrofractures to preferentially propagate east and west due to the regional stress field. The model results indicate that it is unlikely that wells near the site would ever encounter site-related radionuclides. (authors)

03 NATURAL GAS↗

The Lunar Explorer Instrument for Space Biology Applications (LEIA) Pre-Flight Tests: Mechanical Considerations​

The BioSensor payload on the upcoming LEIA platform aboard the CLPS (CP-22) lander will carry yeast to the Moon's south pole to study the effects of lunar radiation and gravity. From Earth, BioSensor will transport desiccated yeast within 16 fluidic cards, each containing 16 fluidic wells of 100 microliters volume. At the start of the experiment, these microbes will be autonomously rehydrated on the Moon, and optical absorbance measurements at three wavelengths will be performed across all 256 wells. Absorbance measurements in fluidic wells are susceptible to noise and artifacts due to bubble formation during well rehydration and microbial growth. BioSensor, as a biofluidics system, faces significant data anomalies caused by payload vibrations, particularly from the operation of the co-located PROSPECT’s ProSEED drill, to assess lunar resources by penetrating the subsurface. To evaluate the impact of drill vibrations, fully assembled and filled fluidic cards were subjected to sine sweep signals in the x, y, z planes, ranging from 5 - 2560 Hz at g-loads of 0.25 and 0.5, with on-board accelerometer for localized vibration measurement. Wells with various fill conditions, including partial fills with different bubble sizes and completely filled wells, were tested. Results indicated that small bubbles adhered to well walls at high frequencies but were dislodged at low frequencies, causing data anomalies. Medium and large bubbles exhibited higher interference with optical data due to lower surface tension and variable bubble surface flexion. Overall, it was found that irrespective of the fill type, low-frequency vibrations were most detrimental to optical readings. Understanding the drill schedule and correlating it with BioSensor timestamps will help identify periods when BioSensor data is unreliable, a crucial step for accurately interpreting the microbial response data and ensuring the validity of the BioSensor's scientific measurements on the lunar surface.

Chinmayee Govinda Raj↗

Assessing Air Velocity Distribution in Three Sizes of Commercial Broiler Houses During Tunnel Ventilation

Abstract. Convective cooling is a critical management strategy for maintaining an environment that promotes production efficiency, thermal comfort, and animal well-being in commercial broiler houses. Variations in house size, design, and equipment configuration contribute greatly to the air velocity distribution within the facility. This study assessed total airflow, air velocity distribution, and quantified the floor area in three facilities experiencing insufficient air velocity for maintenance of production efficiency, thermal comfort, and animal well-being. Test facility 1 was an 18.3 × 170.7 m solid side-wall broiler house, test facility 2 was a 15.24 × 144.8 m solid side-wall broiler house, and test facility 3 was a 12.19 × 121.9 m curtain side-wall broiler house. Total airflow of each facility, measured with a Fan Assessment and Numeration System, was 512,730, 389,495, and 329,270 m 3 h -1 for test facilities 1, 2, and 3, respectively. Air velocity distribution patterns were characterized in each house with a Scalable Environment Assessment System (SEAS) and spatial statistics. The air velocity distributions within the test facilities were variable, with notable maxima immediately downstream of the tunnel inlets, which serve as a well-defined vena contracta, and local minima near the leading end of the evaporative pads and the exhaust fans. Equipment within the facilities had an impact on the air velocity distribution by creating reduced cross-sectional areas that resulted in localized increases in air velocity. The percentage of total bird-level floor area in each facility experiencing air velocities below 1.5 m s -1 was 14.3%, 20.7%, and 10.0% for test facilities 1, 2, and 3, respectively. The effective design velocity (V ed ) was calculated from total airflow using the measured building cross-sectional area. The V ed measured 2.97, 2.45, and 2.34 m s -1 for test facilities 1, 2, and 3, respectively. Mean cross-sectional air velocity (V cs ) was calculated from SEAS data and normalized using each facility’s V ed to account for differences in building size for comparison. Test facility 1, the largest of the three houses, generated substantially higher V cs /V ed than test facilities 2 and 3. Test facilities 2 and 3 maintained a larger proportion of V cs above V ed than test facility 1. Test facility 1 showed 26.5% of the total house length below V ed , while test facilities 2 and 3 had only 20.8% and 17.5%, respectively, of the total house length below V ed . The lower-velocity regions were due to the length of the evaporative cooling pad inlet and the use of tunnel doors, and the exhaust fan placement on the side-walls in test facility 1 created an additional pronounced low-velocity area. Placement of tunnel ventilation fans on the end-wall of the facility, rather than the side-wall, eliminated the low-velocity region at the exhaust end of the facility. Modifications to current practices for broiler production facility construction and evaporative cooling pad inlet installation would be required to minimize the low-velocity region at the inlet end of these facilities. Consideration of house width and physical arrangement of the air inlets, tunnel fans, and internal equipment are critical for improving the uniformity of air velocity in commercial broiler houses. Keywords: Air velocity, Anemometer, Broiler house, FANS, Tunnel ventilation.

Agriculture↗

SU-G-TeP4-15: The Roucoulette: A Set of Quality Control Tests for Dynamic Trajectory (4Pi) Treatment Delivery Techniques

Purpose: To present and validate a set of quality control tests for trajectory treatment delivery using synchronized dynamic couch (translation and rotation), MLC and collimator motion. Methods: The quality control tests are based on the Picket fence test, which consist of 5 narrow band 2mm width spaced at 2.5cm intervals, and adds progressively synchronized dynamic motions. The tests were exposed on GafChromic EBT3 films. The first test is a regular (no motion and MLC static while beam is on) Picket Fence test used as baseline. The second test includes simultaneous collimator and couch rotation, each stripe corresponding to a different rotation speed. Errors in these tests were introduced (0.5 degree and 1 degree error in rotation synchronization) to assess the error sensitivity of this test. The second test is similar to the regular Picket Fence but now including dynamic MLC motion and couch translation (including acceleration during delivery) while the beam is on. Finally in the third test, which is a combination of the first and second test, the Picket Fence pattern is delivered using synchronized collimator and couch rotation and synchronized dynamic MLC and couch translation including acceleration. Films were analyzed with FilmQA Pro. Results: The distance between the peaks in the dose profile where measured (18.5cm away from the isocentre in the inplane direction where non synchronized rotation would have the largest effect) and compared to the regular Picket Fence tests. For well synchronized motions distances between peaks where between 24.9–25.4 mm identical to the regular Picket Fence test. This range increased to 24.4–26.4mm and 23.4–26.4mm for 0.5 degree and 1 degree error respectively. The amplitude also decreased up to 15% when errors are introduced. Conclusion: We demonstrated that the Roucoulette tests can be used as a quality control tests for trajectory treatment delivery using synchronized dynamic motion.

60 APPLIED LIFE SCIENCES↗

Investigation of the Effect of In-Plane Fiber Waviness in Composite Materials through Multiple Scales of Testing and Finite Element Modeling

Defects in materials can reduce strengths and lifetimes of manufactured parts. The number of possible defects increases with the complexity inherent in composite materials. The wind industry uses composite wind turbine blades in which the manufacturing process induces a number of defects. In order for the wind industry to continue sustainable expansion, the effects of defects must be better understood. In-plane (IP) fiber waviness is the focus of this work. The three main parts of this work include testing on the coupon level, modeling on the coupon level, and testing of beams in four-point bending (with and without defects). The coupon level testing includes partial IP waves, similar to those in manufactured parts, rather than full width IP waves. This allows investigation into complex interactions and varying failure mechanisms caused by the fiber misalignment gradient. Partial waves are also modeled to both validate testing as well as to increase robustness of a previously developed progressive damage modeling method. Lastly, a sandwich beam test specimen for testing in 4-point bending is developed to investigate the effects of fiber waviness in both tension and compression when loaded in flexure.

36 MATERIALS SCIENCE↗

A High Temperature Electrochemical Energy Storage System Based on Sodium Beta-Alumina Solid Electrolyte (Base)

This report summarizes the work done during the period September 1, 2005 and March 31, 2008. Work was conducted in the following areas: (1) Fabrication of sodium beta{double_prime} alumina solid electrolyte (BASE) using a vapor phase process. (2) Mechanistic studies on the conversion of {alpha}-alumina + zirconia into beta{double_prime}-alumina + zirconia by the vapor phase process. (3) Characterization of BASE by X-ray diffraction, SEM, and conductivity measurements. (4) Design, construction and electrochemical testing of a symmetric cell containing BASE as the electrolyte and NaCl + ZnCl{sub 2} as the electrodes. (5) Design, construction, and electrochemical evaluation of Na/BASE/ZnCl{sub 2} electrochemical cells. (6) Stability studies in ZnCl{sub 2}, SnCl{sub 2}, and SnI{sub 4} (7) Design, assembly and testing of planar stacks. (8) Investigation of the effect of porous surface layers on BASE on cell resistance. The conventional process for the fabrication of sodium ion conducting beta{double_prime}-alumina involves calcination of {alpha}-alumina + Na{sub 2}CO{sub 3} + LiNO{sub 3} at 1250 C, followed by sintering powder compacts in sealed containers (platinum or MgO) at {approx}1600 C. The novel vapor phase process involves first sintering a mixture of {alpha}-alumina + yttria-stabilized zirconia (YSZ) into a dense ceramic followed by exposure to soda vapor at {approx}1450 C to convert {alpha}-alumina into beta{double_prime}-alumina. The vapor phase process leads to a high strength BASE, which is also resistant to moisture attack, unlike BASE made by the conventional process. The PI is the lead inventor of the process. Discs and tubes of BASE were fabricated in the present work. In the conventional process, sintering of BASE is accomplished by a transient liquid phase mechanism wherein the liquid phase contains NaAlO{sub 2}. Some NaAlO{sub 2} continues to remain at grain boundaries; and is the root cause of its water sensitivity. In the vapor phase process, NaAlO{sub 2} is never formed. Conversion occurs by a coupled transport of Na{sup +} through BASE formed and of O{sup 2-} through YSZ to the reaction front. Transport to the reaction front is described in terms of a chemical diffusion coefficient of Na{sub 2}O. The conversion kinetics as a function of microstructure is under investigation. The mechanism of conversion is described in this report. A number of discs and tubes of BASE have been fabricated by the vapor phase process. The material was investigated by X-ray diffraction (XRD), optical microscopy and scanning electron microscopy (SEM), before and after conversion. Conductivity (which is almost exclusively due to sodium ion transport at the temperatures of interest) was measured. Conductivity was measured using sodium-sodium tests as well as by impedance spectroscopy. Various types of both planar and tubular electrochemical cells were assembled and tested. In some cases the objective was to determine if there was any interaction between the salt and BASE. The interaction of interest was mainly ion exchange (possible replacement of sodium ion by the salt cation). It was noted that Zn{sup 2+} did not replace Na+ over the conditions of interest. For this reason much of the work was conducted with ZnCl{sub 2} as the cathode salt. In the case of Sn-based, Sn{sup 2+} did ion exchange, but Sn{sup 4+} did not. This suggests that Sn{sup 4+} salts are viable candidates. These results and implications are discussed in the report. Cells made with Na as the anode and ZnCl{sub 2} as the cathode were successfully charged/discharged numerous times. The key advantages of the batteries under investigation here over the Na-S batteries are: (1) Steel wool can be used in the cathode compartment unlike Na-S batteries which require expensive graphite. (2) Planar cells can be constructed in addition to tubular, allowing for greater design flexibility and integration with other devices such as planar SOFC. (3) Comparable or higher open circuit voltage (OCV) than the Na-S battery. (4) Wider operating temperature range and higher temperature operation than the Na-S battery. (5) If a cell fails, it fails in the short circuit mode unlike Na-S batteries. Also, cells were successfully subjected to several freeze-thaw cycles. Finally, the feasibility of assembling a planar stack was explored. A two cell stack was assembled and tested. A five cell stack was assembled.

25 ENERGY STORAGE↗

Reliability of PWB Microvias for High Density Package Assembly

High density PWB (printed wiring board) with microvia technology is required for implementation of high density and high I/O area array packages (AAP). COTS (commercial off-the-shelf) AAP packaging technologies in high reliability versions with 1.27 mm pitch are now being considered for use in a number of NASA systems including Space Shuttle and Mars Rovers. NASA functional system designs are requiring more and more dense AAP packages and board space, which makes board microvia technology very attractive for effectively routing a large number of package inputs/outputs. However, the reliability of the fine feature microvias including via in pads is unknown for space applications. Understanding process and QA (quality assurance) indicators for reliability are important for low risk insertion of these newly available packages and PWBs. This paper presents literature search as well as test results for a high density board subjected to various thermal cycle and reflow profiles representative of tin-lead and lead-free solder reflow. Microvias sizes ranged from two to six mil with and without filling. Daisy chain microvias monitored during the test and PWBs were cross-sectioned to determine failure and locations. Optical and SEM photographs as well as resistance changes during cycling and Tg/Td (glass transition/decomposition temperature) characterisations are presented.

fill via↗

3D Printed Materials Characterization for Rapid Prototyping and Plant Growth

Space Biology experimentation but their effects during plant growth and sanitation have not been documented. With further testing we can determine how certain 3D printed materials affect our plants. The way we tested germination included laying two pieces of germination paper down with the printed petri dish insert of the various material and 14 seeds of Outrageous lettuce to fit in the holes of the insert. We kept an even moisture in all parts by wrapping the petri dishes in two layers of parafilm tape. This project tests over 15 different materials to document performance during plant growth scenarios. This research will not only help space biology but also citizens who use these materials to understand the potential of leaching and ill effects. 3D printing is a recent generally accessed technology with new materials coming out every day. It is important to understand how materials could impact the way the plants grow, and the safety of the food grown. As we continue testing these materials, we will also test engineering properties like tension and elasticity. We have a microbiology team working on this project as well to test biofilm formation. From the germination tests we have completed we have seen little impact on germination rate of these seeds. However, some parts absorb moisture. An ideal material is one that doesn’t leach chemicals or microplastics, can withstand high tension and compression, and doesn’t promote microbial growth. This work is funded by NASA. M. Gandhi was funded by MAIANSE.

Mily Gandhi↗

Dynamic Thermal Performance Analysis of PCM Products Used for Energy Efficiency and Internal Climate Control in Buildings

PCMs are attractive for the future generation of buildings, where energy efficiency targets and thermal comfort expectations are increasingly prioritized. Experimental analysis of local thermal processes in these dynamic components and whole-building energy consumption predictions are essential for the proper implementation of PCMs in buildings. This paper discusses the experimental analysis of the thermophysical characteristics of both a latent heat storage material (PCM) and a product containing this PCM. The prototype product under investigation is a panelized PCM technology containing inorganic, salt-hydrate-based PCM. The thermal analysis includes studies of melting and freezing temperatures, enthalpy changes during phase change processes, nucleation intensity, sub-cooling effects, and PCM stability. The PCM’s stability is also investigated, as is the ability of PCM products to control local temperatures and peak load transmission times. Two inorganic PCM formulations based on calcium chloride hexahydrate (CaCl 2 .6H 2 O) were prepared and tested in laboratory conditions. Material-scale testing results were compared with outcomes from the system-scale analysis, using both laboratory test methods as well as field exposure in test huts. This work demonstrates that PCM technologies used in buildings can effectively control both the magnitude of thermal storage capacity as well as the time of the peak thermal load. It was found that commonly used material-scale testing methods may not always be beneficial in assessing the dynamic thermal performance characteristics of building technologies containing PCMs.

42 ENGINEERING↗

Preliminary Results from an Experimental Assessment of a Natural Laminar Flow Design Method

A 5.2% scale semispan model of the new Common Research Model with Natural Laminar Flow (CRM-NLF) was tested in the National Transonic Facility (NTF) at the NASA Langley Research Center. The model was tested at transonic cruise flight conditions with Reynolds numbers based on mean aerodynamic chord ranging from 10 to 30 million. The goal of the test was to experimentally validate a new design method, referred to as Crossflow Attenuated NLF (CATNLF), which shapes airfoils to have pressure distributions that delay transition on wings with high sweep and Reynolds numbers. Additionally, the test aimed to characterize the NTF laminar flow testing capabilities, as well as establish best practices for laminar flow wind tunnel testing. Preliminary results regarding the first goal of validating the new design method are presented in this paper. Experimental data analyzed in this assessment include surface pressure data and transition images. The surface pressure data acquired during the test agree well with computational fluid dynamics (CFD) results. Transition images at a variety of Reynolds numbers and angles of attack are presented and compared to computational transition predictions. The experimental data are used to assess transition due to a turbulent attachment line, as well as crossflow and Tollmien-Schlichting modal instabilities. Preliminary results suggest the CATNLF design method is successful at delaying transition on wings with high sweep. Initial analysis of the transition front images showed transition Reynolds numbers that exceed historic experimental values at similar sweep angles. , section lift

Lynde, Michelle N.↗