Search NASA⌕ Search

SEARCH · Search NASA

Results for “thermal simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

OBSERVATIONAL SIGNATURES OF THE CORONAL KINK INSTABILITY WITH THERMAL CONDUCTION

It is known from numerical simulations that thermal conduction along magnetic field lines plays an important role in the evolution of the kink instability in coronal loops. This study presents the observational signatures of the kink instability in long coronal loops when parallel thermal conduction is included. The three-dimensional nonlinear magnetohydrodynamic equations are solved numerically to simulate the evolution of a coronal loop that is initially in an unstable equilibrium. The loop has length 80 Mm, width 8 Mm, and an initial maximum twist of {Phi} = 11.5{pi}, where {Phi} is a function of the radius. The initial loop parameters are obtained from a highly twisted loop observed in the Transition Region and Coronal Explorer (TRACE) 171 A wave band. Synthetic observables are generated from the data. These observables include spatial and temporal averaging to account for the resolution and exposure times of TRACE images. Parallel thermal conduction reduces the maximum local temperature by up to an order of magnitude. This means that different spectral lines are formed and different internal loop structures are visible with or without the inclusion of thermal conduction. However, the response functions sample a broad range of temperatures. The result is that the inclusion of parallel thermal conductivity does not have as large an impact on observational signatures as the order of magnitude reduction in the maximum temperature would suggest; the net effect is a blurring of internal features of the loop structure.

79 ASTRONOMY AND ASTROPHYSICS↗

Thermal Modeling and Analysis of a Cryogenic Tank Design Exposed to Extreme Heating Profiles

A cryogenic test article, the Generic Research Cryogenic Tank, was designed to qualitatively simulate the thermal response of transatmospheric vehicle fuel tanks exposed to the environment of hypersonic flight. One-dimensional and two-dimensional finite-difference thermal models were developed to simulate the thermal response and assist in the design of the Generic Research Cryogenic Tank. The one-dimensional thermal analysis determined the required insulation thickness to meet the thermal design criteria and located the purge jacket to eliminate the liquefaction of air. The two-dimensional thermal analysis predicted the temperature gradients developed within the pressure-vessel wall, estimated the cryogen boiloff, and showed the effects the ullage condition has on pressure-vessel temperatures. The degree of ullage mixing, location of the applied high-temperature profile, and the purge gas influence on insulation thermal conductivity had significant effects on the thermal behavior of the Generic Research Cryogenic Tank. In addition to analysis results, a description of the Generic Research Cryogenic Tank and the role it will play in future thermal structures and transatmospheric vehicle research at the NASA Dryden Flight Research Facility is presented.

Stephens, Craig A.↗

Test Plan for the Horizontal Dry Cask Simulator

The thermal performance of commercial spent nuclear fuel dry storage casks is evaluated through detailed numerical analysis. These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission(NRC). Canistered dry storage cask systems rely on ventilation between the inner canister and the overpack to convect heat away from the canister to the surrounding environment for both horizontal and vertical configurations. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask in part by increasing the efficiency of internal conduction pathways and by increasing the internal convection through greater canister helium pressure. Carefully measured data sets generated from testing of full sized casks or smaller cask analogs are widely recognized as vital for validating these models. While several testing programs have been previously conducted, these earlier validation studies did not integrate all the physics or components important in a modern, horizontal dry cask system. The purpose of the investigation described in this test plan is to produce data sets that can be used to benchmark the codes and best practices presently used to determine cladding temperatures and induced cooling air flows in modern horizontal dry storage systems. The horizontal dry cask simulator(HDCS) has been designed to generate this benchmark data and add to the existing knowledgebase. The pressure vessel representing the canister has been designed, fabricated, and pressure tested for a maximum allowable pressure(MAWP)rating of 2,400 kPa at400 °C. An existing electrically heated but otherwise prototypic boiling water reactor(BWR), Incoloy-clad test assembly will be deployed inside of a representative storage basket and canister. An insulated sheet metal enclosure will be used to mimic the thermal properties of the concrete vault enclosure used in a modern horizontal storage system. Radial and axial temperature profiles along with induced cooling air flow will be measured for a wide range of decay powers and representative(and higher)cask pressures using various backfills of helium, argon, or air. The single assembly geometry with well-controlled boundary conditions simplifies computational requirements while preserving relevant physics. The proposed test apparatus integrates all the underlying thermal-hydraulics important to defining the performance of a modern horizontal storage system. These include combined-mode heat transfer from the electrically-heated assembly to the canister walls and the primarily natural-convective heat transfer from the canister to the cooling air flow passing through the horizontal vault enclosure. The objective of the HDCS is not to reproduce the performance of a commercial dry storage system for any given set of operational parameters. Rather ,the objective is to capture the dominant physics in a well-characterized test apparatus. The close coupling between the thermal response of the canister system and the resulting induced cooling air flow rate is of particular importance. While incorporating the best available information based on thermal-hydraulic scaling arguments as well as previous vertical testing, this test plan is subject to changes due to improved understanding or from as built deviations to designs. As-built conditions and actual procedures will be documented in the final test report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The thermal stability of coronal loops - Numerical simulations

The radiative stability of thermally isolated coronal loops with free-flow boundary conditions by nonlinear numerical simulation are studied. A chromosphere-to-corona loop equilibrium (including the option of a deep chromosphere) is first established by following the nonlinear evolution from an initial isothermal state with rigid boundaries. The end conditions are then changed, to allow free flow and to fix the temperature, and investigate the response to nonisobaric perturbations. Within a family of loops of the same pressure, long hot loops to be stable and short cool loops to be unstable to the thermal chromospheric-expansion mode are found. The stable cases remain so, even when long chromospheric ends and/or gravity are added. In those cases which are unstable, the subsequent nonlinear evolution which exhibits swelling of the chromosphere until the entire loop becomes cool and dense are followed.

Mok, Y.↗

Test Plan for the Boiling Water Reactor Dry Cask Simulator

The thermal performance of commercial nuclear spent fuel dry storage casks are evaluated through detailed numerical analysis . These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission (NRC). Carefully measured data sets generated from testing of full sized casks or smaller cask analogs are widely recognized as vital for validating these models. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask in part by increasing the efficiency of internal conduction pathways and by increasing the internal convection through greater canister helium pressure. These same vertical, canistered cask systems rely on ventilation between the canister and the overpack to convect heat away from the canister to the environment for both above and below-ground configurations. While several testing programs have been previously conducted, these earlier validation attempts did not capture the effects of elevated helium pressures or accurately portray the external convection of above-ground and below-ground canistered dry cask systems. The purpose of the investigation described in this report is to produce a data set that can be used to test the validity of the assumptions associated with the calculations presently used to determine steady-state cladding temperatures in modern vertical, canistered dry cask systems. The BWR cask simulator (BCS) has been designed in detail for both the above-ground and below-ground venting configurations. The pressure vessel representing the canister has been designed, fabricated, and pressure tested for a maximum allowable pressure (MAWP) rating of 24 bar at 400 deg C. An existing electrically heated but otherwise prototypic BWR Incoloy-clad test assembly is being deployed inside of a representative storage basket and cylindrical pressure vessel that represents the canister. The symmetric single assembly geometry with well-controlled boundary conditions simplifies interpretation of results. Various configurations of outer concentric ducting will be used to mimic conditions for above and below-ground storage configurations of vertical, dry cask systems with canisters. Radial and axial temperature profiles will be measured for a wide range of decay power and helium cask pressures. Of particular interest is the evaluation of the effect of increased helium pressure on allowable heat load and the effect of simulated wind on a simplified below ground vent configuration. While incorporating the best available information, this test plan is subject to changes due to improved understanding from modeling or from as-built deviations to designs. As-built conditions and actual procedures will be documented in the final test report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Simulation Results of a Thermal Power Dispatch System from a Generic Pressurized Water Reactor in Normal and Abnormal Operating Conditions

Amid economic pressures in the U.S. electricity market, nuclear utilities are exploring new revenue streams, including hydrogen production. A generic pressurized water reactor simulator was modified to incorporate a novel design for a TPD system coupled to a hydrogen production plant. Standard malfunctions were included in the simulation design, including steam line breaks at various system locations and flow interruptions in the hydrogen plant due to multiple faults, reflecting anticipated operational challenges. It is imperative that the TPD system operation has a minimal effect on the reactor power, primary coolant system, and turbine system operation and performance. Due to the specific design and application of this TPD system, with the proposed turbine control system changes, the overall impact on the existing plant systems is low. Normal TPD operating scenarios resulted in minor effects on the existing plant systems: reactor power changes by at most 0.2%, and gross generator output changes by 20.5 MWe from 100 MWt of TPD. The most severe malfunction analyzed in this work is a full TPD steam line break downstream of the extraction location, which results in an increase in reactor power of about 0.5%. The gross generator output decreases by 36 MWe, a total decrease of 60 MWe from the full power steady state (FPSS) condition. These results indicate that an industrial hydrogen production plant could be coupled thermally to a nuclear power plant with limited effects on the existing system operation and safety.

08 HYDROGEN↗

The thermal pressure distribution of a simulated cold neutral medium

We numerically study the thermal pressure distribution in a gas with thermal properties similar to those of the cold neutral interstellar gas by analyzing three-dimensional hydrodynamic models in boxes with sides of 100 pc with turbulent compressible forcing at 50 pc and different Mach numbers. We find that at high pressures and for large Mach numbers, both the volume-weighted and the density-weighted distributions can be appropriately described by a log-normal distribution, whereas for small Mach numbers they are better described by a power law. Thermal pressure distributions resulting from similar simulations but with self-gravity differ only for low Mach numbers; in this case, they develop a high pressure tail.

79 ASTRONOMY AND ASTROPHYSICS↗

Simulation with PLACA/DPLACA of thermal and mechanical phenomena in monolithic and dispersed fuel plates

The codes PLACA and DPLACA simulate the irradiation behavior of fuels for research reactors under normal operation conditions. They represent, respectively, plate-type fuels of the monolithic and dispersed types. Both codes contain about thirty interconnected and mutually dependent models structured in a modular scheme. This characteristic gives to the codes a large versatility. To simulate U-Mo/Al dispersion fuels, where the growth of an interaction layer can provoke uncontrolled swelling, a diffusion model with two moving boundaries has been developed. It assumes that the kinetics of both layer boundaries is determined by diffusion of U and Al through the layer. The codes make possible a detailed simulation of the evolution of the more relevant physical parameters of a fuel plate during its permanence within a reactor. Both codes were applied to simulate irradiation histories for which experimental data are available. The good quality of the codes predictions reveals the correct performance of the models involved and the appropriate coupling of the ensemble. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Quadrupole Simulations of Thermographic Responses of Composites

Thermography has been shown to be a viable technique for inspection of composites. The quadrupole method has been shown as a viable technique for rapidedly simulating the thermal repsonse of layered systems. Often, the effort has focused on a one-dimentional models, in particular for improved analysis of thermal data. For composites, the in-plane heat diffusion often significantly impacts the thermal response of defects of interest, therefore three-dimensional simulations are desirable. This paper discusses the extension of the quadrupole methodology to perform simulations of thermographic responses in three-dimensional configuration. This enables the more realistic simulations of the thermal response of delaminiations in composites. The simulations are compared to finite element simulations of the same inspection configurations. The simulations are also compared to the thermographic measurements on composites where shape and depth of the delaminations are known obtained from other sources.

Thermography↗

Simulation of Thermographic Responses of Delaminations in Composites with Quadrupole Method

Thermography has been shown to be a viable technique for inspection of composites. The quadrupole method is a valuable technique for rapidly simulating the thermal response of layered systems. Often, the effort has focused on a one-dimensional model, in particular for improved analysis of thermal data. For composites, the in-plane heat diffusion often significantly impacts the thermal response of defects of interest, therefore three-dimensional simulations are desirable. This paper discusses the extension of the quadrupole methodology to perform simulations of thermographic responses in three-dimensional configurations. This enables the more realistic simulations of the thermal response of delaminations in composites. The simulations are compared to finite element simulations of the same inspection configurations.

Thermography↗

Results for the Aboveground Configuration of the Boiling Water Reactor Dry Cask Simulator

The thermal performance of commercial nuclear spent fuel dry storage casks is evaluated through detailed numerical analysis. These modeling efforts are completed by the vendor to demonstrate performance and regulatory compliance. The calculations are then independently verified by the Nuclear Regulatory Commission (NRC). Carefully measured data sets generated from testing of full-sized casks or smaller cask analogs are widely recognized as vital for validating these models. Recent advances in dry storage cask designs have significantly increased the maximum thermal load allowed in a cask, in part by increasing the efficiency of internal conduction pathways, and also by increasing the internal convection through greater canister helium pressure. These same canistered cask systems rely on ventilation between the canister and the overpack to convect heat away from the canister to the environment for both above- and below-ground configurations. While several testing programs have been previously conducted, these earlier validation attempts did not capture the effects of elevated helium pressures or accurately portray the external convection of above-ground and below-ground canistered dry cask systems. The purpose of the current investigation was to produce data sets that can be used to test the validity of the assumptions associated with the calculations used to determine steady-state cladding temperatures in modern dry casks that utilize elevated helium pressure in the sealed canister in an above-ground configuration.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multidisciplinary Analysis of a Hypersonic Engine

The objective is to develop high fidelity tools that can influence ISTAR design In particular, tools for coupling Fluid-Thermal-Structural simulations RBCC/TBCC designers carefully balance aerodynamic, thermal, weight, & structural considerations; consistent multidisciplinary solutions reveal details (at modest cost) At Scram mode design point, simulations give details of inlet & combustor performance, thermal loads, structural deflections.

Suresh, Ambady↗

Limits on Subcritical Reactivity Determination using Rossi-α and Related Methods

The subcritical reactivity, ρ, of a neutron multiplying system is of interest to many factions of the nuclear community. The subcritical reactivity in a nuclear system can be inferred from measurements of the prompt neutron decay constant, α. Near critical, the reactivity is linearly proportional with α, but the linearity between these quantities does not hold in systems with low multiplication or significantly above prompt critical. This work examines a large range of subcritical prompt neutron decay constant measurements on a thermal HEU metal system. This system is designed to mimic a solution system and to have the optimal H/ 235 U ratio to minimize the critical mass. The reactivity of these measurements varies between 0$\$$ and 70$\$$ below critical. In addition to experimental measurements on the thermal system, simulations are performed on both the thermal HEU system and a fast HEU metal system. Both the fast and thermal results are compared to baseline simulations performed using criticality eigenvalue (KCODE) mode in MCNP®6.2. These simulations are used for comparisons on the linearity between α and ρ. Prompt neutron decay constant measurements in this work are performed using the Rossi-α method. The measurements are taken using a 3 He neutron detection system and a Los Alamos National Laboratory designed list-mode data acquisition system. A specially designed computer program determines α from list-mode data. The α-eigenvalue, or α at delayed critical, for the thermal HEU system is -199:4±4:4 s -1 as measured during this work. The α-eigenvalue for the fast HEU system was previously measured to be -8:5 x 10 -5 s -1 . The results from the thermal HEU system study suggest that the relationship between ρ and α is linear when k eff > 0:80 based on the simulation results. The experimental results also agree with this result, but have less fidelity. No experimental results are available for the fast HEU system.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monte Carlo simulation methods in moment-based scale-bridging algorithms for thermal radiative-transfer problems

We present a moment-based acceleration algorithm applied to Monte Carlo simulation of thermal radiative-transfer problems. Our acceleration algorithm employs a continuum system of moments to accelerate convergence of stiff absorption–emission physics. The combination of energy-conserving tallies and the use of an asymptotic approximation in optically thick regions remedy the difficulties of local energy conservation and mitigation of statistical noise in such regions. We demonstrate the efficiency and accuracy of the developed method. We also compare directly to the standard linearization-based method of Fleck and Cummings [1]. A factor of 40 reduction in total computational time is achieved with the new algorithm for an equivalent (or more accurate) solution as compared with the Fleck–Cummings algorithm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cavity Design, Fabrication and Commission Performance of a 750MHz, 4-rod Separator for CEBAF 4-Hall Beam Delivery System

A short version of the original CEBAF normal conducting 4-rod separator cavity has been developed into a 750MHz one * since the concept of simultaneous 4-hall operation for CEBAF is introduced **. This work has been advanced further based on the EM design optimization, bench measurement and by conducting RF-thermal coupled simulation using CST and ANSYS to confirm the cavity tuning and thermal performance. The cavity fabrication used matured technology like copper plating and machining. The cavity flanges, couplers, tuners and cooling channels adopted consistent/compatible hardware with the existing 500MHz cavities. The electromagnetic and thermal design simulations have greatly reduced the prototyping and bench tuning time of the first prototype. Four production cavities have reached a typical 1.94MV kick voltage or 3.0kW wall loss on each cavity after a minor multipactoring or no processing, 7.5% overhead power than the design specification.

Wang, Haipeng↗

THERMAL INSTABILITY WITH ANISOTROPIC THERMAL CONDUCTION AND ADIABATIC COSMIC RAYS: IMPLICATIONS FOR COLD FILAMENTS IN GALAXY CLUSTERS

Observations of the cores of nearby galaxy clusters show H{alpha} and molecular emission-line filaments. We argue that these are the result of local thermal instability in a globally stable galaxy cluster core. We present local, high-resolution, two-dimensional magnetohydrodynamic simulations of thermal instability for conditions appropriate to the intracluster medium (ICM); the simulations include anisotropic thermal conduction along magnetic field lines and adiabatic cosmic rays. Thermal conduction suppresses thermal instability along magnetic field lines on scales smaller than the Field length ({approx}>10 kpc for the hot, diffuse ICM). We show that the Field length in the cold medium must be resolved both along and perpendicular to the magnetic field in order to obtain numerically converged results. Because of negligible conduction perpendicular to the magnetic field, thermal instability leads to fine scale structure in the perpendicular direction. Filaments of cold gas along magnetic field lines are thus a natural consequence of thermal instability with anisotropic thermal conduction. This is true even in the fully nonlinear regime and even for dynamically weak magnetic fields. The filamentary structure in the cold gas is also imprinted on the diffuse X-ray-emitting plasma in the neighboring hot ICM. Nonlinearly, filaments of cold ({approx}10{sup 4} K) gas should have lengths (along the magnetic field) comparable to the Field length in the cold medium {approx}10{sup -4} pc. Observations show, however, that the atomic filaments in clusters are far more extended, {approx}10 kpc. Cosmic-ray pressure support (or a small-scale turbulent magnetic pressure) may resolve this discrepancy: even a small cosmic-ray pressure in the diffuse ICM, {approx}10{sup -4} of the thermal pressure, can be adiabatically compressed to provide significant pressure support in cold filaments. This is qualitatively consistent with the large population of cosmic rays invoked to explain the atomic and molecular line ratios observed in filaments.

79 ASTRONOMY AND ASTROPHYSICS↗