Search NASA⌕ Search

SEARCH · Search NASA

Results for “variability analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35

A Study of the Kepler K2 Variable EPIC 211957146 Exhibiting a Variable O’ Connell Effect

We present the multi-band photometric and spectroscopic study of an over-contact binary system, EPIC 211957146. The light curves exhibit a variable O’ Connell effect, confirmed from our observational data and the Kepler K2 data. The best photometric solution incorporating a dark spot over the primary component unveils that the system has a low-mass ratio ( q ∼ 0.17) and a high inclination ( i ∼ 85°). To confirm the solution and constrain the uncertainty, Monte-Carlo simulations are performed and the results are reported. Based on the O–C diagram analysis, we see that the variable shows a period increase at the rate of dP / dt ∼ 1.06 × 10{sup −6} days yr{sup −1}, which is higher than the theoretically predicted value. Presence of a third body having a period of ∼16.23 years is evident from the O–C diagram. No filled-in effect is observed in the H α line, while the effect is vividly present in the Na line. From the Kepler K2 data, we found that the primary and secondary minima exhibit an anti-correlated O–C variation followed by an erratic behavior. This is possibly caused by the longitudinal motion of the spot, and hence, we set a lower limit of ∼40 days for the spot modulation. We also observe a possibly associated photometric difference in the primary depth by comparing our light curves with Kepler K2 normalized light curves. This system has a low-mass ratio and a high fill-out factor, and, theoretically, such a physical configuration would lead to a merger.

79 ASTRONOMY AND ASTROPHYSICS↗

Advanced Benchmarking for Complex Building Types: Laboratories as an Exemplar

Complex buildings such as laboratories, data centers and cleanrooms present particular challenges for energy benchmarking because it is difficult to normalize special requirements such as health and safety in laboratories and reliability (i.e., system redundancy to maintain uptime) in data centers which significantly impact energy use. For example, air change requirements vary widely based on the type of work being performed in each laboratory space. We present methods and tools for energy benchmarking in laboratories, as an exemplar of a complex building type. First, we address whole building energy metrics and normalization parameters. We present empirical methods based on simple data filtering as well as multivariate regression analysis on the Labs21 database. The regression analysis showed lab type, lab-area ratio and occupancy hours to be significant variables. Yet the dataset did not allow analysis of factors such as plug loads and air change rates, both of which are critical to lab energy use. The simulation-based method uses an EnergyPlus model to generate a benchmark energy intensity normalized for a wider range of parameters. We suggest that both these methods have complementary strengths and limitations. Second, we present"action-oriented" benchmarking, which extends whole-building benchmarking by utilizing system-level features and metrics such as airflow W/cfm to quickly identify a list of potential efficiency actions which can then be used as the basis for a more detailed audit. While action-oriented benchmarking is not an"audit in a box" and is not intended to provide the same degree of accuracy afforded by an energy audit, we demonstrate how it can be used to focus and prioritize audit activity and track performance at the system level. We conclude with key principles that are more broadly applicable to other complex building types.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Image Analysis for Rapid Assessment and Quality-Based Sorting of Corn Stover

Imaging in the visible spectrum is a low-cost tool that can be readily deployed for in-field or over-belt monitoring of biomass quality for bio-refining operations. Rapid image analysis coupled with innovative preprocessing may reduce the impacts of feedstock variability through identification of contaminants or other material attributes to guide selective sorting and quality management. Image analysis was employed to evaluate the quality of corn stover in red-green-blue (RGB) chromatic space. This study used controlled, bench-scale imaging as a proof-of-concept for rapid quality assessment of corn stover based on variations in material attributes, including chemical and physical attributes, that relate to biological degradation and soil contamination. Additionally, logistic regression-based classification algorithms were used to develop a method for biomass screening as a function of biological degradation or soil contamination. This study demonstrated the use of image analysis to extract features from RGB color space to investigate variations in critical material attributes from chemical composition of corn stover. Fourier transform infrared (FT-IR) suggested a correlation between red band intensity and biological degradation, while detailed surface texture analysis was found to distinguish among variations in ash. These insights offer promise for development of a rapid screening tool that could be deployed by farmers for in-field assessment of biomass quality or biorefinery operators for in-line sorting and process optimization.

09 BIOMASS FUELS↗

Disentangling the Impacts of Microtopography and Shrub Distribution on Snow Depth in a Subarctic Watershed: Toward a Predictive Understanding of Snow Spatial Variability: Supporting Data and Code

This repository contains R code and associated datasets for reproducing the analysis described in the manuscript titled “Disentangling the Impacts of Microtopography and Shrub Distribution on Snow Depth in a Subarctic Watershed: Toward a Predictive Understanding of Snow Spatial Variability” (DOI: 10.1029/2024JG008604). The provided scripts facilitate a comprehensive analysis of snow depth variability influenced by microtopography and vegetation distribution in a subarctic watershed. Included datasets are high-resolution spatial maps of snow depth, terrain elevation, vegetation height, and distance from shrubs taller than 1 meter, all formatted as text files (.txt). These data are fully describe in doi:10.15485/2316038. Users can adapt the provided R scripts to accommodate different data formats or larger spatial domains, noting that some output files may require modification due to their size.The code includes implementations for boosted regression tree analysis adapted from methods outlined in Elith et al. (2008). Users interested in understanding or modeling landscape-scale snow distribution patterns, particularly in Arctic or subarctic ecosystems, will find this package useful. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

TIME-SPECTRAL ANALYSIS ALGORITHMS FOR LEAD SLOWING-DOWN SPECTROSCOPY OF SPENT FUEL

Nondestructively determining the plutonium content in spent fuel assemblies continues to be a considerable challenge in the safeguarding of nuclear fuel cycles. Motivating needs for such measurements include quantifying material input at a reprocessing facility, determining the shipper-receiver difference, and recovering continuity of knowledge. A nondestructive assay (NDA) technology that could provide timely (tens of minutes), independent (no operator-declared information), and direct measurement of Pu mass that improves upon the uncertainty of today’s confirmatory methods would be a major step forward for spent fuel materials accountability. Lead slowing-down spectroscopy (LSDS) is one potential fuel assay technique; previous work has indicated promise of the method for specific fuel types and assay assumptions. In this work, the focus is the assay of pressurized water reactor assemblies over a wide burnup range, under the following assumptions: a) No a priori information (e.g. initial loading or burnup) is available about the assembly, and b) No pre-existing calibration generated from the measurement of many similar assemblies is available. The technical emphasis of this paper is the development of time-spectral analysis algorithms for LSDS that can extract as much isotopic information as possible from the complex, but content-rich assay signal. The key advancement described here is a mathematical relationship to account for self-shielding created by the fissile isotopes and the effects of neutron-absorbing fission and activation products. This formulation utilizes the known energy-dependent cross-sections from key isotopes, but leaves their mass as free variables. Multi-parameter regression analysis is used to directly calculate not only the mass of fissile isotopes in the fuel assembly (e.g. Pu-239, U-235 and Pu-241), but also the mass of key absorbing isotopes such as Pu-240 and U-238. Preliminary results, using a first-order self-shielding relationship, indicate that LSDS has the potential to directly measure total Pu with less than 5% average relative error, over a burnup range from 0 to 60 GWd/MTU. Assay of U-235 and U-238 is also possible, though with higher uncertainties. Deficiencies in the self-shielding model and methods to improve that formulation are described, along with application of the method to a wider range of fuel types and burnups.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

KKT Preconditioners for PDE-Constrained Optimization with the Helmholtz Equation

This paper considers preconditioners for the linear systems that arise from optimal control and inverse problems involving the Helmholtz equation. Specifically, we explore an all-at-once approach. The main contribution centers on the analysis of two block preconditioners. Variations of these preconditioners have been proposed and analyzed in prior works for optimal control problems where the underlying partial differential equation is a Laplace-like operator. In this paper, we extend some of the prior convergence results to Helmholtz-based optimization applications. Our analysis examines situations where control variables and observations are restricted to subregions of the computational domain. We prove that solver convergence rates do not deteriorate as the mesh is refined or as the wavenumber increases. More specifically, for one of the preconditioners we prove accelerated convergence as the wavenumber increases. Additionally, in situations where the control and observation subregions are disjoint, we observe that solver convergence rates have a weak dependence on the regularization parameter. We give a partial analysis of this behavior. We illustrate the performance of the preconditioners on control problems motivated by acoustic testing.

97 MATHEMATICS AND COMPUTING↗

Stream Fish Responses to Grazing Exclosures

Abstract Eight paired reaches of northeastern Oregon streams were selected such that one reach was an established livestock exclosure and a neighboring, geomorphologically similar reach was open to grazing. Exclosures varied in length from 123 to 436 m. Teams of snorkelers recorded fish species and size-groups in the exclosure and grazed reaches simultaneously so that diurnal changes in fish behavior did not confound results. Observed densities of age-0 redband trout Oncorhynchus mykiss in pools, corrected for snorkeler range of vision, were significantly different (P < 10−9), increasing by an average of 2.5-fold in exclosed reaches. Conversely, warmwater fishes (dominated by speckled dace Rhinichthys osculus) were negatively related to exclosures (P < 0.001). Densities of age-0 warmwater fish and age-0 O. mykiss were uncorrelated (P = 0.18). No first-order interactions existed among exclosure–control treatment, stream, and pool temperature variables in either age-0 analysis. Combined juvenile and adult O. mykiss results indicated significant interactions between several streams and temperature and only a marginal effect (P = 0.05) of exclosure. No significant exclosure effect existed on combined juvenile and adult warmwater fish (P > 0.90). The greater density of age-0 O. mykiss in exclosures was attributed to the potential food supply and cover due to increases in undercut banks, instream bank vegetation, width : depth ratio, and several riparian vegetation variables. Bioenergetic and scale arguments are presented that are consistent with the failure to detect a parallel effect with juvenile and adult O. mykiss. A marginally significant (P = 0.04) mean drop in pool water temperature of 0.7°C in exclosures was observed, but continual temperature monitoring indicated no significant difference (P > 0.50) between reaches in 7-d means of daily maxima or minima. These results are promising with respect to improvement of salmonid habitat through prevention of grazing, but the exclosures are too small and infrequent to be effective at the population or basin-wide level.

Bayley, Peter B.↗

Analysis of basic airflow configurations for separate sensible and latent cooling systems with indoor air recirculation

Separate sensible and latent cooling (SSLC) is a technology with efficiency and comfort advantages over conventional cooling systems used for space conditioning of buildings. Using multiple cooling processes at different temperatures allows SSLC to save energy by raising the evaporation temperature of the sensible cooling process. In this paper, all possible airflow configurations of SSLC systems are enumerated under the following constraints: exactly two heat exchangers are used, and air is recirculated to the conditioned space (no exhaust or outdoor air treatment). Seven designs are identified, with varying free operating variables, and each is modeled. Analysis reveals that several configurations are equivalent, and there is only one unique basic airflow SSLC configuration: the one with the sensible and latent heat exchangers placed in series. The efficiency of the SSLC system is compared against that of the conventional system. Under standard conditions, an SSLC system can improve the coefficient of performance by 14.8%. In addition to the numerical simulation, the optimal operating condition of the basic air configuration of the SSLC system is derived analytically. The basic SSLC system is shown to offer the highest performance improvement when the outdoor temperature is relatively cool and the space sensible heat ratio is high.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Intensity Baselining and Tracking Guidance

Each company joining the U.S. Department of Energy’s (DOE’s) Better Buildings, Better Plants Program (Better Plants) commits to establishing an energy consumption and energy intensity (EI) baseline and to tracking its energy performance over a 10-year period against that baseline. The baseline must reflect a company’s energy consumption over a 12-month period, covering all its U.S.-based operations. Energy consumption is calculated by fuel type in terms of primary energy (also known as source energy). EI is broadly defined as the amount of energy consumed per unit of output produced. For this guidance document and for the program, the term energy performance represents an evaluation of a facility’s capacity to use energy efficiently. Metrics used to assess a facility’s energy performance can include EI, energy consumption, improvements in EI, etc. Establishing an energy baseline and tracking system is a critical first step in effectively managing energy use. Developing a baseline can help a company understand energy use within the corporation and give it a point of comparison to evaluate future efforts to improve energy performance. It can also support efforts to validate a company’s energy management activities, improve comparative analyses when using benchmarks, and help in predicting future energy needs. In addition, a company that normalizes its performance data can determine highly defensible measures of energy savings generated through implemented energy efficiency projects. Establishing a baseline and tracking energy performance is also a requirement for ISO 50001 certification. Although basic energy data can be collected through utility bills, most manufacturers will have to perform additional analyses to develop accurate and robust energy baselines and tracking systems. Energy is consumed in many ways within the manufacturing sector and can come from multiple sources. Energy is sometimes generated and sold to other parties or captured and reused on-site. External events can exert a significant impact on a facility or company’s energy use independent of any purposeful efforts to improve energy efficiency. Operational changes, such as production shifts—which may be inevitable for some companies over the 10-year period covered by the program—can also make a big difference in energy use. Since Better Plants asks companies to account for all their U.S.-based operations, mergers, acquisitions, and divestitures can also have significant implications for a company’s energy metrics. This document aims to demystify the sometimes complex baselining process. It devotes special attention to the task of normalizing and adjusting energy consumption to account for external factors, such as weather and production changes. A key recommendation is that companies use regression analysis to normalize their energy consumption data whenever possible. Regression analysis is a statistical technique that estimates the dependence of a variable (i.e., energy use in the context of Better Plants) on one or more independent variables such as ambient temperature, while controlling for the influence of other variables at the same time. A properly developed regression analysis can provide a reliable estimate of energy savings resulting from energy improvement strategies and projects by accounting for the effects of variables such as annual production levels and weather. DOE has developed a companion Energy Performance Indicator software tool (EnPI) to simplify the baselining process. This tool can run regression models, calculate changes in EI at the facility level, and automatically compile facility-level data into a corporate-wide metric. Note that although the relevant equations used to calculate EI are provided in this document, the EnPI tool will automatically perform most calculations for the user. Additionally, Better Plants Partners (Partners) can call on their Technical Account Manager (TAM) to help them establish a baseline and assist with the necessary calculations to track progress.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Impacts of a Weakened Atlantic Meridional Overturning Circulation on ENSO in a Warmer Climate

This study quantifies the impacts of the Atlantic Meridional Overturning Circulation (AMOC) on the El Niño–Southern Oscillation (ENSO) under anthropogenic warming by comparing climate change model simulations with declining and fixed strengths of the overturning. After the 1980s, a weakened AMOC is shown to reduce the strength of the annual cycle of sea surface temperature (SST) in the eastern equatorial Pacific and induce anomalous cross-equatorial northerly winds there, which strengthens ENSO variability by about 11%. An analysis of the Bjerknes stability index reveals that this intensification of ENSO results mainly from enhanced Ekman upwelling feedback due to amplified atmospheric wind response to SST anomalies and oceanic upwelling response to equatorial wind stress anomalies. The weakened AMOC also promotes the occurrence of Central Pacific El Niño events and reduces ENSO skewness. These AMOC impacts on ENSO magnitude and complexity throughout the twenty-first century are however smaller than ENSO variations expected from internal climate variability.

54 ENVIRONMENTAL SCIENCES↗

Effect of Embolization Material in the Calculation of Dose Deposition in Arteriovenous Malformations

In this work it is studied the impact of the incorporation of high Z materials (embolization material) in the dose calculation for stereotactic radiosurgery treatment for arteriovenous malformations. A statistical analysis is done to establish the variables that may impact in the dose calculation. To perform the comparison pencil beam (PB) and Monte Carlo (MC) calculation algorithms were used. The comparison between both dose calculations shows that PB overestimates the dose deposited. The statistical analysis, for the quantity of patients of the study (20), shows that the variable that may impact in the dose calculation is the volume of the high Z material in the arteriovenous malformation. Further studies have to be done to establish the clinical impact with the radiosurgery result.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fast Determination of Distribution-Connected PV Impacts Using a Variable-Time-Step Quasi-Static Time-Series Approach

The increasing deployment of distribution-connected photovoltaic (DPV) systems requires utilities to complete ever more complex interconnection studies. Relatively simple interconnection study methods worked well for low penetrations of photovoltaic systems, but more complicated quasistatic time-series (QSTS) analysis is required to make better interconnection decisions as DPV penetration levels increase. Tools and methods must be developed to support this type of complex analysis to enable efficient completion of PV impact studies. This paper presents a variable-time-step solver for QSTS analysis that significantly shortens the computational time and effort to complete a detailed analysis of the operation of a distribution circuit with many DPV systems. Specifically, it demonstrates that the proposed variable-time-step solver can reduce the required computational time by as much as 84% without introducing any important errors to metrics, such as the number of voltage regulator tap operations and highest and lowest voltage occurring on the distribution circuit during a 1-yr simulation period. Further improvement in computational speed is possible with the introduction of only modest errors in these metrics, such as a 91% reduction with less than 5% error when predicting voltage regulator operations. Furthermore, an alternate variable time-step method is also shown to perform adequately and shows promise of even greater reductions in simulation runtime.

14 SOLAR ENERGY↗

An embedded variable step IMEX scheme for the incompressible Navier–Stokes equations

This report presents a series of implicit–explicit (IMEX) variable stepsize algorithms for the incompressible Navier–Stokes equations (NSE). Here, IMEX means the nonlinear term is treated fully explicitly while the remaining terms are treated implicitly. With the advent of new computer architectures there has been growing demand for low memory solvers of this type. The addition of time adaptivity improves the accuracy and greatly enhances the efficiency of the algorithm. We prove energy stability of an embedded first–second order IMEX pair. For the first order member of the pair, we prove stability for variable stepsizes, and analyze convergence. We believe this to be the first proof of this type for a variable stepsize IMEX scheme for the incompressible NSE. We then define and test a variable stepsize, variable order IMEX scheme using these methods. Our work contributes several firsts for IMEX NSE schemes, including an energy argument and error analysis of a two-step, variable stepsize method, and embedded error estimation for an IMEX multi-step method.

42 ENGINEERING↗

Anisotropic universe with anisotropic sources

We analyze the state space of a Bianchi-I universe with anisotropic sources. Here we consider an extended state space which includes null geodesics in this background. The evolution equations for all the state observables are derived. Dynamical systems approach is used to study the evolution of these equations. The asymptotic stable fixed points for all the evolution equations are found. We also check our analytic results with numerical analysis of these dynamical equations. The evolution of the state observables are studied both in cosmic time and using a dimensionless time variable. Then we repeat the same analysis with a more realistic scenario, adding the isotropic (dust like dark) matter and a cosmological constant (dark energy) to our anisotropic sources, to study their co-evolution. The universe now approaches a de Sitter space asymptotically dominated by the cosmological constant. The cosmic microwave background anisotropy maps due to shear are also generated in this scenario, assuming that the universe contains anisotropic matter along with the usual (dark) matter and vacuum (dark) energy since decoupling. We find that they contribute dominantly to the CMB quadrupole. We also constrain the current level of anisotropy and also search for any cosmic preferred axis present in the data. We use the Union 2 Supernovae data to this extent. An anisotropy axis close to the mirror symmetry axis seen in the cosmic microwave background data from Planck probe is found.

79 ASTRONOMY AND ASTROPHYSICS↗

WISP: Watching grid Infrastructure Stealthily through Proxies (Final Technical Report)

The complex interdependencies of cyber systems (sensors and communications), physical grids and associated electricity market operations make protecting electric power grids a significant challenge. The energy sector is constantly under new, targeted, advanced and dangerous cyber-attacks that have the potential to result in the loss of human life. These threats are further exacerbated by our need to modernize the grid. One focus of cyber security research in smart grids is the securing of the SCADA system through advanced intrusion detection systems (IDS) and bad data detection algorithms in state estimation. These methods either require full knowledge of the system topology and parameters or fail to understand the physical behaviors under attack. WISP (Watching grid Infrastructure Stealthily through Proxies) is designed to provide additional protection to the power grid using only publicly available data. In particular, WISP exploits the spatio-temporal nature of the real time locational marginal prices (LMPs), in conjunction with other information such as bids, weather, outages and load data to analyze anomalous power pricing behaviors and then correlate those observations to localize regions of interest and identify potential cyber events. WISP is non-intrusive as the tool is deployed as a service in the Cloud or on premise and provides reliable information to system operators for enhanced situational awareness, without impeding energy delivery functions. The WISP technology comprises three modules: the data-driven anomaly detection core, the vulnerability and risk analysis and the root cause analysis. The data-driven anomaly detection core performs the tasks of feature selection, anomaly detection and attack region localization. The vulnerability and risk analysis module provides system level information of the vulnerable variables and times, assisting the operators in selecting monitoring and protection nodes. The root cause analysis module takes the detection results and identifies potential operational conditions that contribute to the detected anomalies. In Phase I, we have demonstrated the feasibility and effectiveness of WISP. We developed a realistic electricity market simulator capable of generating normal and attack market data under various operational conditions. We developed a series of cyber-attack detection and analysis algorithms and evaluated them under multiple data sources. Finally, we integrated all modules into an end-to-end software, providing functions for data management, data analytics and visualization. Specifically, we have achieved: (i) real-time data acceptance from external utility interfaces with >99% acceptance rate; (ii) high performance anomaly detection algorithms with >98% detection accuracy and <0.1% false alarm rate; and (iii) ultra-low computing delay <50 milliseconds. Additionally, our team developed algorithms to identify the vulnerable variables in electricity market operations and root cause analysis functions to identify major contributors to the price spikes. These ancillary modules are necessary when deploying WISP in real world industry environment. In Phase II, we have demonstrated the effectiveness of WISP software on realistic largescale power systems. We performed red team testing for the Phase I WISP software and identified software vulnerabilities and implemented corresponding mitigation solutions. We adapted the electricity market simulator for the Texas synthetic 2000-bus system and generated datasets for the false data injection attacks. We created database and visualization interfaces for the Texas system and the ISO New England system. We performed software optimization in terms of operation efficiency, computing speed and detection accuracy. Finally, we tested the software on the Texas system and the ISO New England system and evaluated the detection performance. Overall, we achieved above 89% detection rate, below 3% false alarm rate and below 37 seconds of end-to-end detection delay.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Small vulnerable sets determine large network cascades in power grids

The understanding of cascading failures in complex systems has been hindered by the lack of realistic large-scale modeling and analysis that can account for variable system conditions. Using the North American power grid, we identified, quantified, and analyzed the set of network components that are vulnerable to cascading failures under any out of multiple conditions. We show that the vulnerable set consists of a small but topologically central portion of the network and that large cascades are disproportionately more likely to be triggered by initial failures close to this set. These results elucidate aspects of the origins and causes of cascading failures relevant for grid design and operation and demonstrate vulnerability analysis methods that are applicable to a wider class of cascade-prone networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impacts of Variable Renewable Energy on Bulk Power System Assets, Pricing, and Costs

We synthesize available literature, data, and analysis on the degree to which growth in variable renewable energy (VRE) has impacted to date or might in the future impact bulk power system assets, pricing, and costs. We do not analyze impacts on specific power plants, instead focusing on national and regional system-level trends. The issues addressed are highly context dependent—affected by the underlying generation mix of the system, the amount of wind and solar penetration, and the design and structure of the bulk power system in each region. Moreover, analyzing the impacts of VRE on the bulk power system is a complex area of research and there is much more to be done to increase understanding of how VRE impacts the dynamics of current and future electricity markets. While more analysis is warranted, including additional location-specific assessments, several high-level findings emerge from this synthesis: -VRE Is Already Impacting the Bulk Power Market -VRE Impacts on Average Wholesale Prices Have Been Modest -VRE Impacts on Power Plant Retirements Have So Far Been Limited -VRE Impacts on the Bulk Power Market will Grow with Penetration -The ’System Value’ of VRE will Decline with Penetration -Power System Flexibility Can Reduce the Rate of VRE Value Decline All generation types are unique in some respect—bringing benefits and challenges to the power system—and wholesale markets, industry investments, and operational procedures have evolved over time to manage the characteristics of a changing generation fleet. With increased VRE penetrations, power system planners, operators, regulators, and policymakers will continue to be challenged to develop methods to smoothly and cost-effectively manage the reliable integration of these new and growing sources of electricity supply.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LONG-TERM EVOLUTION OF THE MAIN-ON STATES IN HERCULES X-1

Rossi X-ray Timing Explorer All-sky Monitor (RXTE ASM) observations and American Association of Variable Star Observers (AAVSO) optical data were used for a time-series analysis of the long-term activity of Her X-1. The problem of measuring the long-term evolution of the X-ray intensity in the light curve which consists only of separated intense spikes was addressed. For this purpose, the fluence of each Main-On state was determined. The fluences vary generally (not only in the transitions into/from anomalous low states (ALSs)) by tens of percent on timescales of at least several epochs of the cycle length of the superorbital cycle (but without any stable cycle) while irradiation of the donor producing the optical modulation remains considerably more stable. ALS1 and ALS2 are extensions of the tail in the statistical distribution of these fluences. In this interpretation, the variations of the fluences are caused by the changes of the structure of the inner disk region, which produces variable obscuration of the beams (emitting in the ASM band) at the neutron star. A small change of obscuration of these beams by the inner disk region suffices to change the fluences largely. However, the irradiation of the donor is changed significantly less because this inner disk region (which emits beyond the ASM band and acts as the occulting region of the beams) also irradiates the donor.

79 ASTRONOMY AND ASTROPHYSICS↗