Demonstration of a Fiber Optic Regression Probe in a High-Temperature Flow

The capability to provide localized, real-time monitoring of material regression rates in various applications has the potential to provide a new stream of data for development testing of various components and systems, as well as serving as a monitoring tool in flight applications. These applications include, but are not limited to, the regression of a combusting solid fuel surface, the ablation of the throat in a chemical rocket or the heat shield of an aeroshell, and the monitoring of erosion in long-life plasma thrusters. The rate of regression in the first application is very fast, while the second and third are increasingly slower. A recent fundamental sensor development effort has led to a novel regression, erosion, and ablation sensor technology (REAST). The REAST sensor allows for measurement of real-time surface erosion rates at a discrete surface location. The sensor is optical, using two different, co-located fiber-optics to perform the regression measurement. The disparate optical transmission properties of the two fiber-optics makes it possible to measure the regression rate by monitoring the relative light attenuation through the fibers. As the fibers regress along with the parent material in which they are embedded, the relative light intensities through the two fibers changes, providing a measure of the regression rate. The optical nature of the system makes it relatively easy to use in a variety of harsh, high temperature environments, and it is also unaffected by the presence of electric and magnetic fields. In addition, the sensor could be used to perform optical spectroscopy on the light emitted by a process and collected by fibers, giving localized measurements of various properties. The capability to perform an in-situ measurement of material regression rates is useful in addressing a variety of physical issues in various applications. An in-situ measurement allows for real-time data regarding the erosion rates, providing a quick method for empirically anchoring any analysis geared towards lifetime qualification. Erosion rate data over an operating envelope could also be useful in the modeling detailed physical processes. The sensor has been embedded in many regressing media to demonstrate the capabilities in a number of regressing environments. In the present work, sensors were installed in the eroding/regressing throat region of a converging-diverging flow, with the working gas heated to high temperatures by means of a high-pressure arc discharge at steady-state discharge power levels up to 500 kW. The amount of regression observed in each material sample was quantified using a later profilometer, which was compared to the in-situ erosion measurements to demonstrate the efficacy of the measurement technique in very harsh, high-temperature environments.

Korman, Valentin↗

Significance of ambient conditions in uranium absorption and emission features of laser ablation plasmas

This study employs laser ablation (LA) to investigate mechanisms for U optical signal variation under various environmental conditions during laser absorption spectroscopy (LAS) and optical emission spectroscopy (OES). Potential explored mechanisms for signal quenching related to ambient conditions include plasma chemistry (e.g., uranium oxide formation), ambient gas confinement effects, and other collisional interactions between plasma constituents and the ambient gas. LA-LAS studies show that the persistence of the U ground state population is significantly reduced in the presence of air ambient compared to nitrogen. LA-OES results yield congested spectra from which the U I 356.18 nm transition is prominent and serves as the basis for signal tracking. LA-OES signal and persistence vary negligibly between the test gases (air and N2), unlike the LA-LAS results. The plume hydrodynamic features and plume fundamental properties showed similar results in both air and nitrogen ambient. Investigation of U oxide formation in the laser-produced plasma suggests that low U concentration in a sample hinders consistent detection of UO molecular spectra.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Woven TPS Enabling Missions Beyond Heritage Carbon Phenolic

NASAs Office of the Chief Technologist (OCT) Game Changing Division recently funded an effort to advance a Woven TPS (WTPS) concept. WTPS is a new approach to producing TPS architectures that uses precisely engineered 3D weaving techniques to customize material characteristics needed to meet specific missions requirements for protecting space vehicles from the intense heating generated during atmospheric entry. Using WTPS, sustainable, scalable, mission-optimized TPS solutions can be achieved with relatively low life cycle costs compared with the high costs and long development schedules currently associated with material development and certification. WTPS leverages the mature state-of-the-art weaving technology that has evolved from the textile industry to design TPS materials with tailorable performance. Currently, missions anticipated encountering heat fluxes in the range of 1500 4000 Wcm2 and pressures greater than 1.5 atm are limited to using fully dense Carbon Phenolic. However, fully dense carbon phenolic is only mass efficient at higher heat fluxes g(reater than 4000 Wcm2), and current mission designs suffer this mass inefficiency for lack of an alternative mid-density TPS. WTPS not only bridges this mid-density TPS gap but also offers a replacement for carbon phenolic, which itself requires a significant and costly redevelopment effort to re-establish its capability for use in the high heat flux missions recently prioritized in the NRC Decadal survey, including probe missions to Venus, Saturn and Neptune. This presentation will overview the WTPS concept and present some results from initial testing completed comparing WTPS architectures to heritage carbon phenolic.

Woven Thermal protection materials↗

Mars Sample Return: Grand Challenge for EDL

A year ago, I gave a talk in anticipation of a Mars Sample Return effort at the 9th Ablation Workshop. Since then a lot has happened. "April of this year, after a year of study phase, NASA and ESA (European Space Agency) signed a Statement of Intent (SOI) to jointly develop a Mars Sample Return plan to be submitted to their respective authorities by the end of 2019. This signing is historic, as it signals the desire, the readiness, and the willingness to work together to execute this inspiring mission, we all have the opportunity to tackle this grand challenge. We have the scientific and engineering maturity to identify the critical technologies ready to be applied, and with discipline this campaign can be executed affordably," Jim Watzin, Mars Program Executive, NASA. NASA Centers with JPL (Jet Propulsion Laboratory) leading the charge is in the midst of a pre-formulation phase for executing a Mars Sample Return before the end of next decade. The proposed talk builds on the previous year talk. In light of the agreement between NASA and ESA, NASA has assumed the responsibilities for developing the earth entry vehicle (EEV) that will fly along with a European Spacecraft and return with the sample from Mars. EEV will be deployed for entry into earth. The EEV design, development, testing and certification have to result in a highly reliable sample return system. The entire architecture has to be demonstrated to meet the planetary protection requirement. NASA is considering two distinctly different earth entry vehicle architectures and with each choice, many different ablative TPS (Thermal Protective Shield) candidates. As a result of the NASA-ESA ongoing studies, some of the key entry conditions and design requirements are better understood today and more are being scoped out. The heat-shield ablative TPS choice need to be done with a good understanding as it plays a very significant role in determining the robustness of the EEV. Knowledge about how materials and system perform, and how the features could become flaws and how flaws lead to failure, etc. need to be clearly understood and the knowledge then need to be used to down select the TPS. This proposed talk will provide greater insight into the progress being made and the challenges that need to be tackled.

Mars Sample Return: Grand Challenge for EDL↗

A Physics-Aligned Multi-Domain Machine Learning Framework for Time-Localised Diagnosis of Power Electronics Faults

This paper presents a physics-aligned framework for fault diagnosis in multi-phase power-electronic systems using cycle-synchronous windowing and multi-domain features derived from Fourier, wavelet, and Hilbert–Huang representations. While both logistic regression and multilayer perceptron (MLP) models achieve perfect performance under standard evaluation, blind unseen testing reveals a critical failure in a baseline MLP. This is shown to arise from model selection based on validation accuracy. Using validation-loss-based selection restores correct unseen performance and improves confidence. Feature ablation shows that Fourier and wavelet features dominate, while computational analysis indicates that feature extraction, particularly HHT, governs runtime.

Kumar, Praveen [ORNL] (ORCID:0000000291877857)↗

Inserting a Low-Refractive-Index Dielectric Rear Reflector into PERC Cells: Challenges and Opportunities

One of the simplest and most effective ways to reduce the operating temperature of photovoltaic systems in the field is to reflect unusable, 'sub-bandgap' light with energies below the cell absorber's bandgap energy. In this work, low-refractive index SiO2 nanoparticle films inserted between c-Si wafers and metal electrodes significantly increase the reflectance of sub-bandgap light in fabricated test structures. These films are then integrated into the standard PERC fabrication sequence, revealing that the reflection benefits remains after some processing steps but are lost in certain conditions. The SiO2 nanoparticle films are easily ablated during laser contact opening, but are undesirably etched during post-laser cleaning. After Al metallization, the fully fabricated devices show enhanced sub-bandgap reflection when annealed at moderate temperatures, but energy-dispersive X-ray spectroscopy shows that high-temperature firing causes unwanted Al penetration into the SiO2 nanoparticle film, compromising reflection.

14 SOLAR ENERGY↗

Long-time stress relaxation of a filled elastomer in vacuum environments

Samples of a filled elastomeric ablative material were stored at 45 C and 10 to the -6th torr for 7 months. Their tensile stress-relaxation modulus at constant strain was measured throughout the 7 months. Results of the testing are discussed primarily by comparisons of the data to atmospheric-pressure moduli (determined in this work for shorter periods of time) and with moduli predicted from short-time testing. Confirmation of the strengthening effects of vacuum on this composite was obtained. The use of time-temperature superposition techniques as an approximate accelerated testing procedure for this material under these conditions was also verified.

Ward, T. C.↗

Postflight aerothermodynamic analysis of Pegasus(tm) using computational fluid dynamic techniques

The objective was to validate the computational capability of the NASA Ames Navier-Stokes code, F3D, for flows at high Mach numbers using comparison flight test data from the Pegasus (tm) air launched, winged space booster. Comparisons were made with temperature and heat fluxes estimated from measurements on the wing surfaces and wing-fuselage fairings. Tests were conducted for solution convergence, sensitivity to grid density, and effects of distributing grid points to provide high density near temperature and heat flux sensors. The measured temperatures were from sensors embedded in the ablating thermal protection system. Surface heat fluxes were from plugs fabricated of highly insulative, nonablating material, and mounted level with the surface of the surrounding ablative material. As a preflight design tool, the F3D code produces accurate predictions of heat transfer and other aerodynamic properties, and it can provide detailed data for assessment of boundary layer separation, shock waves, and vortex formation. As a postflight analysis tool, the code provides a way to clarify and interpret the measured results.

Kuhn, Gary D.↗

Real Gas/Blunt Cone

In this chapter recent activity in real-gas database definition and code validation will be summarized. In the Phase I report of the Working Group (WG) 181, aerothermodynamic problems were classified, for purpose of discussion, into seven types: aerodynamic parameters, viscous/shock interaction, boundary-layer transition, forebody-heating/heat-transfer, radiation and ablation, lee and base-region flow, and low-density flow. Several of these problem types were the subject of various chapters of the Phase 1 report describing real-gas effects and ground test facility issues. In this chapter some background and objectives outlined in the real-Gas effects Chapter V of the Phase 1 report will be reviewed. The results of the blunt cone test campaign developed under the auspices of the WG18 activity to study real-gas phenomena will be summarized, including the experimental and computational programs, issues and questions, and recommendations. Further, recent progress in other real-gas areas beyond the blunt cone test campaign will be discussed. Finally, a summary in which the present status of our understanding of real-gas issues will be presented.

George S. Delwert↗

Ares: A Coupling Methodology for Ablation Modeling

To enable modeling of complex and coupled ablation problems, a multi-physics framework is developed. A methodology for modeling shape change in coupled systems is presented. The approach taken to model gas-surface interactions and translate coupled surface phenomena to physically meaningful boundary conditions in the distinct solvers is discussed. Particular emphasis is placed on the nature of coupled boundary conditions pertaining to surface energy and mass balances as well as surface chemistry modeling. The developed methodology is used to simulate a shear test in arc-jet conditions in order to assess the validity of the coupled approach as well as the implementation of the relevant physical processes.

EDL↗

Treatment of Metastatic Lymph Nodes in the Neck from Papillary Thyroid Carcinoma with Percutaneous Laser Ablation

PurposeTo assess the effectiveness of percutaneous laser ablation (PLA) of cervical lymph node metastases from papillary thyroid carcinoma.Materials and Methods24 patients (62.3 ± 13.2 year; range 32–80) previously treated with thyroidectomy, neck dissection, and radioiodine ablation underwent ultrasound-guided PLA of 46 {sup 18}FDG-PET/CT—positive metachronous nodal metastases. All patients were at high surgical risk or refused surgery and were unsuitable for additional radioiodine ablation. A 300 µm quartz fiber and a continuous-wave Nd-YAG laser operating at 1.064 mm were used. Technical success, rate of complications, rate of serological conversion, and local control at follow-up were derived. Fisher’s exact test and Mann–Whitney U test were used and Kaplan–Meier curve calculated.ResultsTechnical success was obtained in all 46 lymph nodes (100 %). There were no major complications. Thyroglobulin levels decreased from 8.40 ± 9.25 ng/ml before treatment to 2.73 ± 4.0 ng/ml after treatment (p = 0.011), with serological conversion in 11/24 (45.8 %) patients. Overall, local control was obtained in 40/46 (86.9 %) lymph nodes over 30 ± 11 month follow-up, with no residual disease seen at imaging in 19/24 (79.1 %) patients. Local control was achieved in 40/46 (86.9 %) lymph nodes at 1 year and in all of the 25 nodes (100 %) followed for 3 years. Estimated mean time to progression was 38.6 ± 2.7 m.ConclusionUltrasound-guided PLA is a feasible, safe, and effective therapy for the treatment of cervical lymph node metastases from papillary thyroid carcinoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development and Testing of a Green-Propellant Micro-Hybrid Thruster with Electrostatic Ignition

As early as 1937 German scientists at Peenemunde experimented with highly unstable fuel blends of nitrous oxide (N2O) and ethanol. These early tests mostly resulted in explosions and destroyed rocket engines. More recently several companies have developed experimental nitrous oxide fuel blends (NOFB) with Isp exceeding 300 sec. Although NOFBx has recently been cleared for tests on the International Space Station, this propellant remains highly experimental and has not been cleared for commercial transport by the US DOT. Recent work by Karabeyoglu et al. has raised concerns about the safety risks of mixing hydrocarbons with N2O. Liquid oxidizer/fuel blends are highly explosive and require extreme care in transport and servicing. By adding small amounts of a liquid organic fuel such as alcohol or a hydrocarbon, the odds of an explosive decomposition event are significantly increased.iv The proposed solution mitigates the explosion hazards of NOFB by separating the oxidizer from the hydrocarbon fuel formed as of a small cylindrical section of ABS thermoplastic. As N2O vapor flows across the grain segment, current enters a 1000 VDC high-tension lead in the ABS fuel grain and produces an inductive spark that vaporizes a small amount of the material. The ablated fuel vapor plus residual energy from the spark seed a localized exothermic N2O dissociation that produces sufficient heat to initiate combustion. The process is also effective when gaseous oxygen is used. A low TRL (2-3) prototype demonstrating the feasibility of controlled hydrocarbon-seeding was recently tested at Utah State University.v The unit features a miniature 2.5 cm ABS fuel grain fabricated using a Stratasys Dimension 3-D printer. The 9-N thruster was pulse-fired up to 27 consecutive times on a single ABS grain segment. Ignition was achieved by as little as 12-15 Joules energy input. This value is contrasted with the typical 30-minute pre-heat requirement for the ECAPS LMP-103S ADN-based monopropellant, requiring an energy input of 14,850 Joules for catalytic dissociation. The hydrocarbon-seeded micro-hybrid was also adapted as a non-pyrotechnic ignitor for a 900 N (200-lbf) thrust hybrid motor. The motor was successfully ignited 4 consecutive times with no hardware swaps or propellant additions. The amount of ABS seed material that can be fit into the injector cap is the only limit to the number of available repeat firings. This series of tests marks the first time a hybrid motor was ever ignited by other than a solid-propellant pyrotechnic charge or bi-propellant flame ignitor. Nitrous oxide hybrid motors are typically difficult to ignite and usually require multiple solid-propellant charges to initiate combustion, so this nonpyrotechnic ignition is a significant accomplishment. The controlled hydrocarbon-seeding approach is fundamentally different from all other green propellant solutions offered by the aerospace industry. Although the proposed system is more correctly a hybrid technology; the system retains all the simple features of a monopropellant design. To date no optimization study has been performed to identify the best grain geometry for electrostatic ignition. Fortunately, because the grain segments are fabricated using rapid-prototyping technology, changing the grain geometry is as simple as modifying the 3-D printer CAD-file. Vacuum Isp exceeding 270 seconds has been demonstrated (Ref v), a value significantly higher than those offered by competing green monopropellant options. The propellants of choice, N2O/GOX and ABS are 100% non-toxic, non-explosive, and environmentally benign. Because the inert oxidizer and fuel components are mixed only within the combustion chamber, the system retains the inherent safety of a hybrid rocket and can be piggy-backed as a secondary payload with no overall mission risk increase to the primary payload, an excellent characteristic for secondary launch systems.

Whitmore, Stephen A.↗

Development of the Algol III solid rocket motor for SCOUT.

The design and performance of a motor developed for the first stage of the NASA SCOUT-D and E launch vehicles are discussed. The motor delivers a 30% higher total impulse and a 35 to 45% higher payload mass capability than its predecessor, the Algol IIB. The motor is 45 in. in diameter, has a length-to-diameter ratio of 8:1 and delivers an average 100,000-lb thrust for an action time of 72 sec. The motor design features a very high volumetrically loaded internal-burning charge of 17% aluminized polybutadiene propellant, a plasma-welded and heat-treated steel alloy case, and an all-ablative plastic nose liner enclosed in a steel shell. The only significant development problem was the grain design tailoring to account for erosive burning effects which occurred in the high-subsonic-Mach-number port. The tests performed on the motor are described.

Felix, B. R.↗

Ablation of ATJ Graphite at High Temperatures

Results of an extensive experimental program on the ablation of ATJ graphite in air at surface pressures of 0.3 to 4.4 atm and surface temperatures of 2570 to 4030 K are presented. The measured mass-loss rates are correlated with surface temperature, pressure, and effective nose radius. The results are compared with several equilibrium thermochemical ablation theories which differ basically in the chemical species that are considered and in the thermodynamic properties assigned to these species. All the theories predict about the same mass-loss rate in the diffusion-controlled oxidation regime and are in good agreement with the experimental results. At higher temperatures, however, the experimental and theoretical results do not agree. At temperatures above 3700 K, the experimental mass-loss rate becomes independent of pressure and an exponential function of temperature. A comparison of the high-temperature results with the theories indicates that all the theories, except the one based on the thermodynamic properties from the JANAF tables, are invalid because they overpredict the mass-loss rate. On the other hand, the theory based on the JANAF properties underpredicts the measured mass-loss rate by a factor of three at 4000 K. At least a portion of this difference between experiment and theory is attributed to particulate mass loss which is visually observed.

Thermochemical ablation↗

Orion Heat Shield Manufacturing Producibility Improvements for the EM-1 Flight Test Program

This paper describes how the Orion program is incorporating improvements in the heat shield design and manufacturing processes reducing programmatic risk and ensuring crew safety in support of NASA’s Exploration Missions. The Orion program successfully completed the EFT-1 flight test in 2014 and is currently developing the EM-1 spacecraft to meet the test objectives of an orbital mission to the moon and return to earth in 2019. Lessons learned from the EFT-1 manufacturing and flight test experience are being incorporated into a wide variety of vehicle systems and manufacturing processes to reduce risk to the Orion missions and flight crew. A critical contributor to crew safety is the heat shield that protects the crew capsule during re-entry through the earth’s atmosphere for return from deep space. The first flight test vehicle, EFT-1, was manufactured and tested in the Neil Armstrong Operations and Checkout (O&C) facility at KSC to demonstrate early risk reduction including the functionality of the Thermal Protection Systems (TPS) for capsule safe return to earth. The approach for the EFT-1 heat shield utilized a low risk approach using Apollo heritage design and manufacturing processes using an Avcoat TPS ablator with a honeycomb substrate to provide a one piece heat shield to meet the mission re-entry heating environments. The manufacturing processes used honeycomb cell injection guns which were redeveloped from the Apollo Lunar Program processes to build the EFT-1 heat shield. The completed heat shield was transported across the country by aircraft to the O&C at KSC for installation onto the capsule. The EFT-1 heat shield successfully performed its mission and experienced ~80% of the re-entry velocity (50% heating rate) for a lunar return for an Exploration Mission. The second flight test vehicle is the EM-1 mission which will have additional flight systems installed to fly to the moon and return. Heat shield design and producibility improvements have been incorporated in the EM-1 vehicle to meet deep space mission and programmatic requirements. The design continues to use the Avcoat material, but in a “block” configuration to enable improvements in the application processes as well as additional improvements in the carrier structure design and manufacturing operations. Incorporating flight test results and producibility improvements from EFT-1 for the heat shield system design and processes have improved the thermal protection capability, improved the producibility, and cost for EM-1 flight test.

Producibility↗

Effect of macular ablation on frequency and latency of motion-induced emesis in the squirrel monkey

Three previously motion-emetic sensitive squirrel monkeys were rendered refractory to a standard motion-emetic regimen by a two-stage utriculosacculectomy procedure which preserved the cristae ampullares of semicircular canals. Three nonoperated control squirrel monkeys tested on the same motion-emetic regimen time schedule as the operated animals remained motion-emetic sensitive with regard to incidence, frequency, and latency of motion-induced emetic responses. Following a sham surgical procedure (stapedectomy) performed on two of the latter animals and one additional new animal, the emetic incidence decreased from 100 to 89 percent, but the frequency and latency were not altered significantly.

Brizzee, Kenneth R.↗

Lung Volume Reduction After Stereotactic Ablative Radiation Therapy of Lung Tumors: Potential Application to Emphysema

Purpose: Lung volume reduction surgery (LVRS) improves dyspnea and other outcomes in selected patients with severe emphysema, but many have excessive surgical risk for LVRS. We analyzed the dose-volume relationship for lobar volume reduction after stereotactic ablative radiation therapy (SABR) of lung tumors, hypothesizing that SABR could achieve therapeutic volume reduction if applied in emphysema. Methods and Materials: We retrospectively identified patients treated from 2007 to 2011 who had SABR for 1 lung tumor, pre-SABR pulmonary function testing, and ≥6 months computed tomographic (CT) imaging follow-up. We contoured the treated lobe and untreated adjacent lobe(s) on CT before and after SABR and calculated their volume changes relative to the contoured total (bilateral) lung volume (TLV). We correlated lobar volume reduction with the volume receiving high biologically effective doses (BED, α/β = 3). Results: 27 patients met the inclusion criteria, with a median CT follow-up time of 14 months. There was no grade ≥3 toxicity. The median volume reduction of the treated lobe was 4.4% of TLV (range, −0.4%-10.8%); the median expansion of the untreated adjacent lobe was 2.6% of TLV (range, −3.9%-11.6%). The volume reduction of the treated lobe was positively correlated with the volume receiving BED ≥60 Gy (r{sup 2}=0.45, P=.0001). This persisted in subgroups determined by high versus low pre-SABR forced expiratory volume in 1 second, treated lobe CT emphysema score, number of fractions, follow-up CT time, central versus peripheral location, and upper versus lower lobe location, with no significant differences in effect size between subgroups. Volume expansion of the untreated adjacent lobe(s) was positively correlated with volume reduction of the treated lobe (r{sup 2}=0.47, P<.0001). Conclusions: We identified a dose-volume response for treated lobe volume reduction and adjacent lobe compensatory expansion after lung tumor SABR, consistent across multiple clinical parameters. These data serve to inform our ongoing prospective trial of stereotactic ablative volume reduction (SAVR) for severe emphysema in poor candidates for LVRS.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of MRI-guided Focused Ultrasound as Organ-Sparing Treatment for Testicular Cancer

High cure rates for testicular cancer have prompted interest in organ-sparing surgery for patients with bilateral disease or single testis. Focused ultrasound (FUS) ablation could offer a noninvasive approach to organ-sparing surgery. The objective of this study was to determine the feasibility of using MR thermometry to guide organ-sparing focused ultrasound surgery in the testis. The testes of anesthetized rabbits were sonicated in several discrete locations using a single-element focused transducer operating at 2.787MHz. Focal heating was visualized with MR thermometry, using a measured PRF thermal coefficient of -0.0089{+-}0.0003 ppm/ deg. C. Sonications at 3.5-14 acoustic watts applied for 30 seconds produced maximum temperature elevations of 10-80 deg. C, with coagulation verified by histology. Coagulation of precise volumes in the testicle is feasible with MRI-guided focused ultrasound. Variability in peak temperature for given sonication parameters suggests the need for online temperature feedback control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗