Search NASA⌕ Search

SEARCH · Search NASA

Results for “Absolute pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Role of metabolic gases in bubble formation during hypobaric exposures

Our hypothesis is that metabolic gases play a role in the initial explosive growth phase of bubble formation during hypobaric exposures. Models that account for optimal internal tensions of dissolved gases to predict the probability of occurrence of venous gas emboli were statistically fitted to 426 hypobaric exposures from National Aeronautics and Space Administration tests. The presence of venous gas emboli in the pulmonary artery was detected with an ultrasound Doppler detector. The model fit and parameter estimation were done by using the statistical method of maximum likelihood. The analysis results were as follows. 1) For the model without an input of noninert dissolved gas tissue tension, the log likelihood (in absolute value) was 255.01. 2) When an additional parameter was added to the model to account for the dissolved noninert gas tissue tension, the log likelihood was 251.70. The significance of the additional parameter was established based on the likelihood ratio test (P < 0.012). 3) The parameter estimate for the dissolved noninert gas tissue tension participating in bubble formation was 19. 1 kPa (143 mmHg). 4) The additional gas tissue tension, supposedly due to noninert gases, did not show an exponential decay as a function of time during denitrogenation, but it remained constant. 5) The positive sign for this parameter term in the model is characteristic of an outward radial pressure of gases in the bubble. This analysis suggests that dissolved gases other than N2 in tissues may facilitate the initial explosive bubble-growth phase.

NASA Center JSC↗

Plasma decay of nanosecond pulsed laser-produced Ar and Ar–H 2 O sparks at atmospheric pressure

Time-resolved diagnostics were applied to investigate free-electron properties in nanosecond laser-produced discharges generated in atmospheric pressure Ar and in Ar–3%H 2 O. The discharges were generated using 23 ns, 1064 nm laser pulses. Broadband plasma imaging and laser Thomson scattering were combined with optical emission spectroscopy, with particular emphasis on the Stark broadening of the H α and H β lines. The plasma exhibited a bright emission that persists for up to 30–40 µs after breakdown. Plasma emission was then followed by a very weak glow emission that persisted for up to 19 ms after breakdown. Peak electron number density of ∼2 × 10 17 cm −3 and electron temperature of ∼7 eV were measured. An excellent agreement between both techniques was obtained regarding absolute electron number densities. The inferred free-electron temporal decay dynamics are consistent with processes dominated by hydrodynamic expansion and two- and three-body electron–ion recombination. These results provide benchmark data for modeling nanosecond laser discharges and demonstrate the reliability of combining Thomson scattering with Stark broadening in atmospheric laser sparks.

Thomson scattering↗

Hollow cathode, quasi-steady MPD arc

A quasi-steady MPD accelerator has been operated with four different hollow cathodes over a power range from 5 kilowatts to 5 megawatts. The absolute level of the argon mass flow, as well as the fractional division of the flow between the cathode and the six standard chamber injectors, is varied over a range of 1 to 12 grams per second. For a fixed total current, it is observed that the voltage increases monotonically with mass flow rate, compared to the usual experience with solid cathodes where the voltage decreases with mass flow rate. For a fixed percentage of flow through the cathode, each hollow cathode configuration displays a minimum impedance at a particular value of the total mass flow. It is asserted that in order to keep the discharge inside the hollow cathode the magnetic pressure and gasdynamic pressure have to match inside the cavity.

Parmentier, N.↗

Apparatus for Testing Flat Specimens of Thermal Insulation

An apparatus has been developed to implement an improved method of testing flat-plate specimens of thermal-insulation materials for cryogenic application. The method includes testing under realistic use conditions that could include vacuum and mechanical loading at a pressure up to 70 psi (=0.48 MPa). The apparatus can accommodate a rigid or flexible specimen having thickness up to 1.25 in. (=3.2 cm) and diameters between 6 and 10 in. (about 15.2 and 25.4 cm, respectively). Typical test conditions include boundary temperatures between 77 K and 373 K and vacuum/interstitial gas filling at a pressure between 10(exp -6) torr (=1.3 x 10(exp -4) Pa) and 760 torr (atmospheric pressure =0.1 MPa). The interstitial gas could be N2, He, CO2, or any other suitable gas to which the insulation is expected to be exposed in use. Relative to prior apparatuses and testing methods, this apparatus and the testing method that it implements offer advantages of relative simplicity and ease of use. The basic principle of operation of the apparatus is that of boil-off calorimetry, using liquid nitrogen or any other suitable liquid that boils at a desired temperature below ambient temperature. Comparative rates of flow of heat through the thicknesses of the specimens (heat-leak rates) and apparent-thermal-conductivity values are obtained from tests of specimens. Absolute values of heat-leak rates and apparent thermal conductivities are computed from a combination of (1) the aforementioned comparative values and (2) calibration factors obtained by testing reference specimens of materials that have known thermal-insulation properties. The apparatus includes a full complement of temperature sensors, a vacuum pump and chamber, a monitoring and control system, and tools and fixtures that enable rapid and reliable installation and removal of specimens. A specimen is installed at the bottom of the vacuum chamber, and a cold-mass assembly that includes a tank is lowered into position above and around the specimen (see figure). A spring-based compensating fixture helps to ensure adequate thermal contact with possibly irregular specimen surfaces. For a high-compression test, the springs can be replaced with spacers. A flat circular load cell at the bottom of the chamber measures the compressive load on the specimen. Once the desired compressive-load, temperature, and vacuum/gas-filling conditions are established, testing begins. During a test, all measurements are recorded by use of a portable data-acquisition system and a computer. The total heat-leak rate is measured and calculated as the boil-off flow rate multiplied by the latent heat of vaporization. The parasitic heat leak (to the side of the specimen and to the top and side of the cold-mass tank) is reduced to a small fraction of the total heat leak by use of a combination of multilayer-insulation (MLI) shield rings, reflective film, a fiberglass/epoxy centering ring, and a bulk fill of aerogel beads. This combination eliminates the need for a cryogenic guard chamber used in a typical prior apparatus to reduce the parasitic heat leak.

Fesmire, James E.↗

Dehydrogenation vs Apparent Hydrogenation: Unraveling the Mechanisms of He and O 2 Plasma Etching on Colloidal Nanocrystal Films

Removing organic ligands from colloidal nanoparticles is critical for fabricating solid-state devices, yet accurately quantifying this removal remains a significant analytical challenge. Here, we establish a robust and accessible method for this quantification by calibrating Raman spectroscopy against precise ion beam analysis (IBA) for nanoparticle assemblies (CNAs) processed by helium (He) and oxygen (O 2 ) plasmas. We demonstrate that the calibration curves are remarkably independent of plasma power and pressure, depending critically only on the choice of feed gas. He plasma induces rapid dehydrogenation and cross-linking, evidenced by a much faster decrease in the C–H Raman signal relative to the actual carbon loss. Conversely, O 2 plasma leads to a surprising “apparent hydrogenation”, where the carbon backbone is removed significantly faster than the C–H signal diminishes. This counterintuitive effect is explained by a serial mechanism of oxidative fragmentation; β-scission cleaves the alkyl chains, and subsequent stabilization steps enrich the remaining film with hydrogen-rich methyl-terminated fragments, while carbon is efficiently removed as volatile CO. This work provides calibrated functions that enable the rapid determination of absolute carbon content in processed CNAs using simple Raman spectroscopy with uncertainties of ∼8% for O 2 and ∼12% for He plasma, offering a vital tool for both process diagnostics and fundamental studies of plasma–matter interactions in colloidal nanocrystal films.

Animal feed↗

Emissions mitigation technology for advanced water-lean solvent-based CO 2 capture processes

This technical final report submitted to DOE/NETL presents all the research activities performed during the entirety of DE-FE0031660 project-Emissions Mitigation Technology for Advanced Water-Lean Solvent-Based CO 2 Capture Processes which spans from October 2018 through March 2022. RTI International has been conducting studies from fundamental and operational aspects to reduce the overall amine emissions from the advanced Water-Lean Solvent (WLS) systems, specifically RTI’s Non-Aqueous Solvent (NAS). This technical final report will highlight the key findings from project which align closely to the project objectives which are: Identify the contribution of vapor loss, entrainment, and aerosols to the overall emissions of water-lean systems; Determine the significance of CO 2 capture system operating parameters to the amine emissions; Develop an emissions model based on critical operating parameters; Evaluate the effectiveness of emissions mitigation devices to reduce the amine emissions to <1 ppm under flue coal-fired flue gas; and, Determine the contribution of the ECTs to the overall CO 2 capture cost. The following are the key findings based on numerous tests using both lab-scale setups and parametric testing performed at RTI’s Bench-scale Gas Absorption System (BsGAS). During the BP1, the aerosol generation system and monitoring equipment were installed at BsGAS to produce and determine the aerosol characteristics during the NAS CO 2 capture process. The aerosol produced by this setup produced aerosols with the peak diameter and concentration of 50 micron and 1.2E10 7 cm -3 , respectively. These particle sizes and concentrations are matched to those observed in the actual coal-fired power plant flue gases and expected to be found at the absorber inlet of the CO 2 capture system. Over 1,300 hours of parametric testing have been conducted to evaluate the impact of the aerosols and operating conditions during the CO 2 capture with NAS on the overall amine emissions in the treated flue gas. At the worse condition tested, the presence of the aerosols in the flue gas could increase the overall emissions by 10X compared to the baseline emissions from NAS’s vapor pressure. CO 2 capture rate was found to be a main factor impacting the overall emissions as well as aerosol size and concentrations in the absorber off-gas. The higher CO 2 capture rate, the higher amine emissions in the treated gas. The temperature difference between the temperature bulge seen in the absorber and the water wash temperature also impacts the particle growth where the larger the temperature difference, the more amine emissions from aerosols in the treated gas. The majority of the aerosols did not grow substantially in the system, and the particle concentrations remained nearly constant between the absorber inlet and wash outlet. Only a small portion of the particles were found to grow significantly. The high efficiency demister with mesh size of 5-10 micron can be installed to remove a portion of the aerosols from the gas stream leaving the water wash. Overall, these results from parametric testing have established the emission baseline and validate our assumption on the need of emission control technologies (ECT) in order to minimize the emissions from the baseline NAS CO 2 capture process. Over 2,000 of BsGAS operating hours was used to investigate a handful of process improvements which led to a selection of the vital few changes that effectively control the amine emissions. These process improvements are lime-coated-filters for absorber gas inlet, advanced demister at the top of the absorber, a second water wash with amine recovery unit were designed, installed, and tested at BsGAS at the end of BP1. The result showed that the NAS CO 2 capture process with these additional emission control devices could lower the amine emission in the treated gas to about 1 ppm using a simulated coal-fire flue gas stream. The main contributor in lowering the amine emission came from the second water wash with amine recovery unit where the amine concentration in the scrubbing water was kept below 2 wt% through a continuous amine removal via an adsorbent bed, resulting in a low amine vapor pressure. The adsorbent bed was regenerated via a direct steam regeneration and the recover amine was returned to the absorber to minimize wastewater and makeup amine. A flue gas generation system was designed and installed during the first half of BP2 to support the emission testing using a real coal-derived flue gas. The system is capable of generating both coal- and natural gas- derived flue gases with the composition of the gaseous species highly resemble to that of the power plant flue gases. The particulates detected in the coal-derived flue gas showed the mean diameter of 1 micron. The CO 2 capture operating was then proceed using the real coal-derived flue gas where the amine emission was controlled to be about 0-3 ppm for the total run time of about 200 hours. Similar testing was conducted with natural gas-derived flue gas and the result showed a highly amine emission of 30 ppm under the total run time of 200 hours. The Principal Component Analysis (PCA) and the Partial Least Squares Projection to Latent Structures (PLS) techniques were applied to the parametric testing data to derive a multivariate statistical model. The model was validated and trained with half of the data collected, and the predictive ability of the model was evaluated using the remaining half of the data. The resulting empirical model was capable of predicting the overall emissions from the NAS process without the ECTs with ±15% accuracy (average absolute deviation, AAD) in BP1. As more emission data were obtained under the real coal-flue gas in the BP2, the model incorporated these new set of data to reflect the final process configuration, operating parameters, and amine emission. This results in the updated empirical model predicting the amine emission from the NAS CO 2 capture process with 84% goodness-of-fit (R 2 ), 85% predictability (Q 2 ), and 15% AAD. The study evaluates the use of RTI’s Non-Aqueous Solvent technology for 90% CO 2 capture from a net 650 MWe pulverized coal power plant, downstream of the flue-gas desulfurization unit. The captured CO 2 has a purity of > 95% CO 2 , and is dried, compressed to 15.3 MPa (2,215 psia), ready for sequestration. The analysis uses Case B12B from the DOE Baseline study on Bituminous Coal, Revision 4 where the Cansolv CO 2 capture plant is replaced by the RTI CO 2 Capture plant. The CO 2 capture plant has been sized to capture >90% CO 2 from flue gas derived from a net 650 MWe supercritical pulverized coal power plant. The CO 2 capture plant is equipped with emission control technologies that limits the amine emissions to < 1 ppm. Two different cases were evaluated for the technoeconomic study. The key difference between the two cases is the regenerator pressure. In Case 1, the regenerator operates at 0.195 MPa (28.3 psia), whereas in Case 2, the regenerator pressure is 0.44 MPa (64 psia) thus removing the need for the first stage of compression of the eight-stage compression train. Results from the TEA are compared against the DOE reference cases for SCPC plant with and without CO 2 Capture (Case B12A and Case B12B of the DOE Baseline study, respectively). Case 2 with CO 2 regeneration at higher pressure results in the lower cost of CO 2 capture. The total capital cost of the capture process has been estimated using 2018 dollars in Aspen Process Economic Analyzer and was estimated to be $579 MM. The capture plant operation leads to a total parasitic power loss rate of 96 MWe, resulting in a decrease in pulverized coal power plant efficiency of 7.8% points. The resulting cost of electric power increases from 64.4 mills/kWh, for no capture, to 97.5 mills/kWh, with 90% capture, an increase of 51% in the COE. The cost of capturing 90% CO 2 was estimated to be $38.2/tonne-CO 2 , and meets the DOE target of $40/t-CO 2 . Emission control technologies (ECT) investigated in this project includes a second water wash with use of activated carbon beds for removal of amine from the wash water prior to recirculation in the water wash. These ECT allow operation of the CO 2 capture plant with < 1 ppm amine emissions with the treated flue gas and contributes to $2.4/t-CO 2 captured. Amine emissions derived from thermal and oxidative degradations were investigated under this project along with the emissions derived from aerosols for the NAS system. The thermally degraded of the lean NAS showed less than 4% decreased of the original total amine content in the NAS at 150 °C while the result obtained at 120 °C showed no drop in total amine content, suggesting that thermal degradation of the NAS is minimal. These results also suggested that the thermally degraded species are not likely formed and contributed to the emissions due to the low regeneration temperature of the NAS at 90-105 °C. The oxidative degradation, on the other hand, could become problematic as some of these oxidative degraded species were observed during the NAS-5 testing at National Carbon Capture Center (NCCC) and SINTEF in our previous project. The rapid screening of selected inhibitors suggested that oxidative degradation of NAS can be suppressed using thiol containing compounds in amounts of at least 1 mol%. The detailed mechanistic degradation pathway was conceived for a specific amine used in NAS formulation during BP2. he reduction of the nitrosamines caused by the NO x present in the flue gas was also examined. The study suggested that the thermo-chemical treatment of the NAS solvent would be a more effective and economically viable compared to removing NO x at the DCC.

01 COAL, LIGNITE, AND PEAT↗

Spatially resolved methane band photometry of Jupiter. I - Absolute reflectivity and center-to-limb variations in the 6190-, 7250-, and 8900-A bands. II - Analysis of the south equatorial belt and south tropical zone reflectivity

Spatially resolved measurements of the absolute reflectivity and center to limb variations of Jupiter in the 6190, 7250 and 8900 A methane bands and nearby continuum regions are presented and analyzed for the south equatorial belts (SEBs) and south tropical zone (STrZ). It is found that the polar hoods, equatorial zone, Red Spot and north tropical zone have highest methane reflectivities, with the temperate zones and polar regions having low reflectivity and the STrZ and SEBs having intermediate values. The data on the SEB and STrZ are analyzed in terms of diffuse reflecting-scattering and two-cloud models of the vertical distribution of aerosols in the Jovian atmosphere. To fit observations, the STrZ cloud top must have between 0.55 and 0.43 bar total pressure and optical depth between 1.5 and 2.5. The reflecting-scattering models are not suitable for the SEBs. The SEB upper cloud is deeper, cloud thickness is less and the lower cloud is deeper than in the STrZ. A forward scattering haze layer accounts for limb darkening in the continuum.

West, R. A.↗

Noninvasive Indicators of Intracranial Pressure Before, During, and After Long-Duration Spaceflight

Weightlessness induces a cephalad shift of blood and cerebrospinal fluid that may increase intracranial pressure (ICP) during spaceflight, while lower body negative pressure (LBNP) may provide an opportunity to caudally redistribute fluids and lower ICP. To investigate the effects of spaceflight and LBNP on noninvasive indicators of ICP (nICP), we studied thirteen crewmembers before and after spaceflight in seated, supine, and 15° head-down tilt postures, and at ~45 and ~150 days of spaceflight with and without 25 mmHg LBNP. We used 4 techniques to quantify nICP: cerebral and cochlear fluid pressure (CCFP), otoacoustic emissions (OAE), ultrasound measures of optic nerve sheath diameter (ONSD), and ultrasound-based internal jugular vein pressure (IJVp). On flight day 45, two nICP measures were lower than preflight supine posture (CCFP: mean difference -98.5 -nl [CI: -190.8 to -6.1 -nl], p = 0.037]; OAE: -19.7 degrees [CI: -10.4 to -29.1 degrees], p < 0.001), but not significantly different from preflight seated measures. Conversely, ONSD was not different than any preflight posture, whereas IJVp was significantly greater than preflight seated measures (14.3 mmHg [CI: 10.1 to 18.5mmHg], p < 0.001), but not significantly different than preflight supine measures. During spaceflight, acute LBNP application did not cause a significant change in nICP indicators. These data suggest that during spaceflight nICP is not elevated above values observed in the seated posture on Earth. Invasive measures would be needed to provide absolute ICP values and more precise indications of ICP change during various phases of spaceflight.

Jessica V. Jasien↗

Quantitative Detection of Products and Radical Intermediates in Low-Temperature Oxidation of Cyclopentane

We present a combined experimental and theoretical investigation of the autoignition chemistry of a prototypical cyclic hydrocarbon, cyclopentane. Experiments using a high-pressure photolysis reactor coupled to time-resolved synchrotron VUV photoionization mass spectrometry directly probe the short-lived radical intermediates and products in cyclopentane oxidation reactions. We detect key peroxy radical intermediates ROO and OOQOOH, as well as several hydroperoxides, formed by second O 2 addition. Automated quantum chemical calculations map out the R + O 2 + O 2 reaction channels and demonstrate that the detected intermediates belong to the dominant radical chain-branching pathway: ROO (+ O 2 ) → γ-QOOH + O 2 → γ-OOQOOH → products. ROO, OOQOOH, and hydroperoxide products of second-O 2 addition undergo extensive dissociative ionization, making their experimental assignment challenging. We use photoionization dynamics calculations to aid in their characterization and report the absolute photoionization spectra of isomerically pure ROO and γ-OOQOOH. Here, a global statistical fit of the observed kinetics enables reliable quantification of the time-resolved concentrations of these elusive, yet critical species, paving the way for detailed comparisons with theoretical predictions from master-equation-based models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A chemical kinetic analysis of knock propensity of methanol-to-gasoline fuel

Production of low carbon gasoline-like fuels such as methanol-to-gasoline (MTG) is a promising approach to achieve rapid greenhouse gas emission reduction of the transportation sector. Despite the fact that gasoline that meets the ASTM D4814 standard for automotive spark-ignition engine fuel can be readily produced from these processes, it is unclear how the composition of MTG may affect engine performance and emissions. Here, in this paper, a surrogate for an MTG is used to numerically study the effects of gasoline composition on knock propensity and on the sensitivity of knock to thermal and fuel stratification, to oxygen dilution and to nitric oxide from exhaust gas recirculation of residual gases. Simulations were performed in ANSYS CHEMKIN-PRO using a comprehensive chemical kinetic mechanism for gasoline surrogates, and results of the MTG surrogate were compared against those of a petroleum-based regular E10 gasoline, termed PACE-20. A premium-grade MTG fuel was also formulated by adding ethanol to the MTG surrogate, and results were compared against those of four premium-grade, gasoline-like fuels representative of future alternative gasoline formulations. Surrogates and mechanism were evaluated by comparison against experimental engine data, and the model showed high accuracy at stoichiometric conditions (mean absolute error of ignition timing equal to 1.46 crank angle degrees) but larger deviations at lean conditions (mean absolute error of ignition timing equal to 5.52 crank angle degrees). Despite the fact that the MTG surrogate has a RON 1.1 units higher than that of PACE-20, it may show higher knock propensity at medium temperature conditions due to a less intense NTC behavior. MTG autoignition was more temperature- and equivalence ratio-sensitive than that of PACE20, suggesting that MTG can benefit more from naturally-occurring thermal stratification or from induced fuel stratification of the end gas to mitigate knock intensity. The sensitivity of autoignition reactivity to oxygen dilution and to NO concentration was higher for MTG than for regular gasoline at medium loads, but the opposite trend was observed at high loads due to the effect of pressure on the low-temperature chemistry of regular gasoline. Approximately 14 % vol ethanol content was required to upgrade the octane rating of MTG from regular grade to premium grade. Adding 13.6 % vol ethanol made the fuel autoignition less sensitive to both oxygen dilution and NO content (ignition time varies approx. 17 % and 50 % less with oxygen dilution and NO addition, respectively, when adding ethanol at high engine loads).

02 PETROLEUM↗

An improved viscid/inviscid interaction procedure for transonic flow over airfoils

A new interacting boundary layer approach for computing the viscous transonic flow over airfoils is described. The theory includes a complete treatment of viscous interaction effects induced by the wake and accounts for normal pressure gradient effects across the boundary layer near trailing edges. The method is based on systematic expansions of the full Reynolds equation of turbulent flow in the limit of Reynolds numbers, Reynolds infinity. Procedures are developed for incorporating the local trailing edge solution into the numerical solution of the coupled full potential and integral boundary layer equations. Although the theory is strictly applicable to airfoils with cusped or nearly cusped trailing edges and to turbulent boundary layers that remain fully attached to the airfoil surface, the method was successfully applied to more general airfoils and to flows with small separation zones. Comparisons of theoretical solutions with wind tunnel data indicate the present method can accurately predict the section characteristics of airfoils including the absolute levels of drag.

Melnik, R. E.↗

Precision measurements of photoabsorption cross sections of Ar, Kr, Xe, and selected molecules at 58.4, 73.6, and 74.4 nm

Absolute absorption cross sections have been measured for the rare gases at 58.43, 73.59, and 74.37 nm with an accuracy of + or - 0.8 percent. For the molecules H2, N2, O2, CO, N2O, CO2, and CH4, precision measurements were made at 58.43 nm with an accuracy of + or - 0.8 percent. Molecular absorption cross sections are also reported at 73.59 and 74.37 nm. However, in the vicinity of these wavelengths most molecules exhibit considerable structure, and cross sections measured at these wavelengths may depend on the widths and the amounts of self-reversal of these resonance lines. A detailed discussion is given of the systematic errors encountered with the double-ion chamber used in the cross-sectional measurements. Details are also given of precision pressure measurements.

Samson, James A. R.↗

Diagnostic Clast-Texture Criteria for Recognition of Impact Deposits

It is difficult to find definitive evidence for impact in the geological record because there are many endogenous geological processes that can produce diamictites similar to those generated by impact ejecta. The classic impact criteria of shock fabrics in certain minerals, and iridium layers, for example, may be either difficult to find, or long-since erased from the impact site (shock fabrics also anneal with time). It is important to be able to recognize impact-generated materials in order to understand earth's crustal development and biological evolution. In future exploration of Mars and other solar-system bodies, recognition of impact materials will be important for elucidating planetary evolution, planetary volatile inventories, and exobiological issues. The cobble depicted is typical of many that have been found in diamictite deposits in Belize generated by the Chicxulub K-T impact event. The pebbles are roughly-hewn in general shape with smoothed corners and edges. Surfaces are almost uniformly frosted (on both protuberances and hollows), but some asperities are glazed. Optical microscopy and thin-section petrographic microscopy reveal the frosting to be only a few microns thick, with a well-defined granular structure; grains are the same size as those composing the bulk of the limestone, but their clearer appearance may represent annealing. One or two adjacent pebble faces are often decorated with striated gouges and closely-spaced hemispherical depressions representing indentation hollows produced by well-rounded impacting clasts of up to 0.5 cm in diameter. Some of the impactors are still embedded in the cobble surface. Non-destructive x-ray diffraction techniques showed the impactors to be of the same mineralogy as the target cobble. We believe this unusual glazing and frosting to be related to the impact event, but this must be reconciled with its survival for over 60 my. since it is composed of one of the most alterable substances, CaCO3. We focus, however, on the non-fractured rounded pebbles that appear to have impacted the larger cobble as a swarm of clasts, probably encountered during ballistic flight. It cannot be defined whether the cobble swept through the pebble cloud, or the pebbles rained upon a slowermoving cobble. Two interesting questions arise: (1) Where did large numbers of such well rounded pebbles come from in the ejecta curtain?, and (2) How did they embed themselves in a nominally brittle rock without suffering damage? Are the well-rounded pebbles crystalline (devitrified) melt spherules? Further investigations are in progress. If the cobble was cold and brittle, impact of well-rounded pebbles would have produced Hertzian fracture patterns (a) in the virtually elastically isotropic cobble target. For penetration depths of about 0.5 of the impactor diameter, the pebbles would require a relative impact velocity sufficient to cause pebble fragmentation and crushing, and the development of a complex Hertzian-Boussinesq fracture field (b) involving deep fracturing and lateral surface spalling (impact velocities > 50 m/s). The existing relationship could only evolve by the impact of cold, hard pebbles into a soft, plastic cobble surface (c). For limestone to have been plastic, it must have been at elevated temperature, but to prevent calcification of the material, the ambient pressure must also have been elevated. This would be possible either in the impact's gas plume, or within the confines of a thin aerodynamically-produced shock bow generated by supersonic ballistic motion of the cobble. In the latter case, it is implied that the cobble swept through the pebbles rather than vice-versa. Although there are high T-P conditions associated with volcanism, such textures have not been reported on volcaniclastic materials, nor from other high T-P environments; e.g., metamorphic (as far as the authors are aware). We propose that this very easily recognizable embedding and indentation surface texture can be used as a diagnostic criterion for the recognition of impact ejecta. The term "peening texture" is suggested, because it is absolutely analogous to the plastic-deformation induced, metal-surface textures generated by ball-bearing bombardment used in engineering metallurgy to work-harden metal surfaces. Additional information is contained in the original (Figures).

Marshall, J. R.↗

Bayesian inference of the incompressibility, skewness and kurtosis of nuclear matter from empirical pressures in relativistic heavy-ion collisions

Within the Bayesian statistical framework we infer the incompressibility K 0 , skewness J 0 and kurtosis Z 0 parameters of symmetric nuclear matter (SNM) at its saturation density ρ 0 using the constraining bands on the pressure in cold SNM in the density range of 1.3ρ 0 to 4.5ρ 0 from transport model analyses of kaon production and nuclear collective flow in relativistic heavy-ion collisions. As the default option assuming the K 0 , J 0 and Z 0 have Gaussian prior probability distribution functions (PDFs) with the means and variances of 235±30, -200±200 and -146±1728 MeV, their posterior most probable values are narrowed down to 192$^{+12}_{-16}$ MeV, -180$^{+100}_{-110}$ MeV and ${\mathrm{200}}_{-250}^{+250}$ at 68% confidence level, respectively. The results are largely independent of the prior PDFs of J 0 and Z 0 used. However, if one adopts the strong belief that the incompressibility K 0 has a uniform prior PDF within its absolute boundary of 220–260 MeV as one can find easily in the literature, the posterior most probable values of K 0 , J 0 and Z 0 shift to ${K}_{0}=22{0}_{-0}^{+6}$ MeV, ${J}_{0}=-39{0}_{-70}^{+60}$ MeV and ${Z}_{0}=60{0}_{-200}^{+200}$ MeV, respectively. While the posterior PDFs of the SNM EOS parameters depend somewhat on the prior PDF of K 0 used, the results from using different prior PDFs are qualitatively consistent. The uncertainties of all three parameters are significantly reduced especially for the J 0 and Z 0 parameters compared to their current values.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Utah FORGE: Neubrex Well 16B(78)-32 Circulation Test Fiber Optics Monitoring Data and Reports - July, 2023

This dataset features Distributed Acoustic Sensing (DAS) and fiber optics monitoring data acquired by Neubrex Energy Services during the Utah FORGE Well 16B(78)-32 circulation test in July 2023. DAS and fiber optic monitoring data include absolute strain, strain change, strain change rate, distributed temperature sensing (DTS), and frequency band extraction (FBE). Data processing was completed between September and October 2023. The dataset includes the fiber optic sensing data collected during these operations, along with a data collection report, descriptions of the data, and instructions for reading the data files.

15 GEOTHERMAL ENERGY↗

Ice in space: An experimental and theoretical investigation

The thermodynamics of water ice formation was experimentally investigated under a wide variety of conditions, including those of outer space. This information, and in particular, the lifetime of ice particles as a function of solar distance is an absolute requirement for proper interpretation of photometric profiles of comets. The sublimation of ice particles in a nonequilibrium situation was studied. An oscillating fiber microbalance was used to measure the sublimation rate of water droplets (which were suspended on a long quartz fiber which was oscillating in a vacuum chamber). The influence of particle size, surface temperature, and the index refraction from simulated solar radiation were studied in relation to ice formation. Also examined was the influence of impurities (clathrates) on ice formation. Windows in the vacuum chamber allowed the ice particles to be exposed to a 1 kilowatt xenon arc lamp which was used to simulate solar radiation. Ice is proposed as a possible energy source for comets, as amorphous water ice and ammonia in low temperature and pressure environments demonstrated a clear energy release upon warming. Motion pictures of ice formation were taken and photographs are shown.

Patashnick, H.↗

Outer atmospheres of cool stars. VIII - IUE observations and chromospheric models for the supergiant stars Beta Draconis, Epsilon Geminorum, and Alpha Orionis

A semiempirical modeling of stellar chromospheres is extended to late-type supergiants, where computations match high-resolution, absolute-flux profiles of the Ca II K and Mg II h and k lines. IUE UV spectra of Epsilon Gem and Alpha Ori show no evidence of emission lines formed at temperatures greater than 10,000 K, leading to the computation of chromospheric models extending to 10 to the -6th g/sq cm at temperatures that rise to 6500 K for the former star and 7000 K for the latter. By contrast, the C II-IV, Si IV, and He II and N V strong emission lines of Beta Dra lead to a tentative chromospheric model extension to 16,000 K at 0.012 dynes/sq cm. It is pointed out that the Ca II and Mg II line analyses presented, which assume hydrostatic equilibrium with only thermal and turbulent components to the pressure, imply nearly plane-parallel chromospheres even in the case of Alpha Ori.

Basri, G. S.↗

Helium metastable density determination in the COST reference source by absolutely calibrated optical emission spectroscopy

Helium metastable densities in the COST Reference Microplasma Jet are estimated for a variety of He/N2 admixtures and dissipated powers by applying a collisional-radiative model to absolutely calibrated optical emission spectroscopy measurements. This is accomplished by delineating the excitation mechanisms that result in the N2(C–B) and N2+(B–X) emission bands, the latter of which is strongly coupled to the presence of helium metastables. A number of other plasma parameters are established and discussed for each operating condition including the electron energy distribution function, reduced electric field, rate constants, and electron density. With these parameters, the reaction rates for the primary ionization pathways are also calculated, emphasizing the importance of helium metastables for discharge sustainment. Good agreement with the existing literature is found for most plasma parameters and for helium metastable densities, in particular. A clear [N2]−1 relationship between the nitrogen concentration and density of helium metastables is demonstrated, as has been identified in previous studies in analogous atmospheric pressure plasma jets. This validates the efficacy of this optical technique for determining helium metastable densities and establishes it as a viable, and in many cases, more accessible alternative to other means of quantifying helium metastables in low-temperature plasmas.

Physics↗