Search NASA⌕ Search

SEARCH · Search NASA

Results for “Alpha Particles”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Proton decay from the isoscalar giant dipole resonance in {sup 58}Ni

Proton decay from the 3({Dirac_h}/2{pi}){omega} isoscalar giant dipole resonance (ISGDR) in {sup 58}Ni has been measured using the ({alpha},{alpha}{sup '}p) reaction at a bombarding energy of 386 MeV to investigate its decay properties. We have extracted the ISGDR strength under the coincidence condition between inelastically scattered {alpha} particles at forward angles and decay protons emitted at backward angles. Branching ratios for proton decay to low-lying states of {sup 57}Co have been determined, and the results compared with predictions of recent continuum-RPA calculations. The final-state spectra of protons decaying to the low-lying states in {sup 57}Co were analyzed for a more detailed understanding of the structure of the ISGDR. It is found that there are differences in the structure of the ISGDR as a function of excitation energy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

2p-2p decay of {sup 8}C and isospin-allowed 2p decay of the isobaric-analog state in {sup 8}B

{sup 8}C is found to decay to four protons and an {alpha} particle in two 2p emission steps. The correlations between the protons in the first step ({sup 8}C to {sup 6}Be) exhibit a significant enhancement in the region of the decay phase space where the two protons have small relative energy, a region sometimes called the diproton region. The decay of the isobaric analog of {sup 8}C in {sup 8}B is also found to decay by 2p emission. This is the first case of isospin-allowed 2p decay between isobaric analog states.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Multi-parametric approach towards the assessment of radon and thoron progeny exposures

Conventionally, the dosimetry is carried out using radon and thoron gas concentration measurements and doses have been assigned using assumed equilibrium factors for the progeny species, which is inadequate pertaining to the variations in equilibrium factors and possibly due to significant thoron. In fact, since the true exposures depend upon the intricate mechanisms of progeny deposition in the lung, therefore an integrated approach for the assessment of progeny is essential. In this context, the recently developed deposition based progeny concentration measurement techniques (DTPS: Direct Thoron progeny sensors and DRPS: Direct Radon progeny sensors) appear to be best suited for radiological risk assessments both among occupational workers and general study populations. DTPS and DRPS consist of aluminized mylar mounted LR115 type passive detectors, which essentially detects the alpha particles emitted from the deposited progeny atoms on the detector surface. It gives direct measure of progeny activity concentrations in air. DTPS has a lower limit of detection limit of 0.1 Bq/m{sup 3} whereas that for DRPS is 1 Bq/m{sup 3}, hence are perfectly suitable for indoor environments. These DTPS and DRPS can be capped with 200-mesh type wire-screen to measure the coarse fraction of the progeny concentration and the corresponding coarse fraction deposition velocities as well as the time integrated fine fraction. DTPS and DRPS can also be lodged in an integrated sampler wherein the wire-mesh and filter-paper are arranged in an array in flow-mode, to measure the fine and coarse fraction concentration separately and simultaneously. The details are further discussed in the paper.

61 RADIATION PROTECTION AND DOSIMETRY↗

TENDL-2011: TALYS-based Evaluated Nuclear Data Library

The 4. release of the TENDL library, TENDL-2011 (TALYS-based Evaluated Nuclear Data Library) is described. This library consists of a complete set of nuclear reaction data for incident neutrons, photons, protons, deuterons, tritons, helions and alpha particles, from 10-5 eV up to 200 MeV, for all isotopes from {sup 6}Li to {sup 281}Ds that are either stable of have a half-life longer than 1 second. All data are completely and consistently evaluated using a software system consisting of the TALYS-1.2 nuclear reaction code, and other programs to handle resonance data, experimental data, data from existing evaluations, and to provide the final ENDF-6 formatting. The result is a nuclear data library with mutually consistent reaction information for all isotopes and a quality that increases with yearly updates. To produce this library, TALYS input parameters are adjusted for many nuclides so that calculated cross sections agree with experimental data, while for important nuclides experimental data are directly included. All information is available on www.talys.eu and www.talys.eu/TENDL-2011. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Nuclear Incompressibility and the Asymmetry Term: Implications for Astrophysics and Physics with Exotic Nuclei

The compressional-mode giant resonances, the isoscalar giant monopole resonance (GMR) and the isoscalar giant dipole resonance (ISGDR), in various isotopes have been investigated using inelastic scattering of 400-MeV alpha-particles at extremely forward angles, including 0 deg. Recently, the centroid energies of the giant monopole resonance (GMR) in the Sn isotope region are found to be significantly lower than the theoretical predictions. In addition, based on the GMR results, the asymmetry-term in the nuclear incompressibility has been determined as K{sub t}au = -550+-100 MeV. Constraints on interactions employed in nuclear structure calculations are discussed on the basis of the experimentally values for K{sub i}nfinity and K{sub t}au. The combination of these two values gives stringent constraints on the interactions used for nuclear structure calculations and for formations of equation of state (EOS) of nuclear matter. A short review of the current status of the experimental studies on the compressional-mode giant resonances is given, and a possible new experiment for astrophysics and physics with exotic nuclei is suggested.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-C-201-05: Imaging 212Pb-TCMC-Trastuzumab for Alpha Radioimmunotherapy for Ovarian Cancer

Purpose: To support the phase I trial for toxicity, biodistribution and pharmacokinetics of intra-peritoneal (IP) 212Pb-TCMC-trastuzumab in patients with HER-2 expressing malignancy. A whole body gamma camera imaging method was developed for estimating amount of 212Pb-TCMC-trastuzumab left in the peritoneal cavity. Methods: {sup 212}Pb decays to {sup 212}Bi via beta emission. {sup 212}Bi emits an alpha particle at an average of 6.1 MeV. The 238.6 keV gamma ray with a 43.6% yield can be exploited for imaging. Initial phantom was made of saline bags with 212Pb. Images were collected for 238.6 keV with a medium energy general purpose collimator. There are other high energy gamma emissions (e.g. 511keV, 8%; 583 keV, 31%) that penetrate the septae of the collimator and contribute scatter into 238.6 keV. An upper scatter window was used for scatter correction for these high energy gammas. Results: A small source containing 212Pb can be easily visualized. Scatter correction on images of a small 212Pb source resulted in a ∼50% reduction in the full width at tenth maximum (FWTM), while change in full width at half maximum (FWHM) was <10%. For photopeak images, substantial scatter around phantom source extended to > 5 cm outside; scatter correction improved image contrast by removing this scatter around the sources. Patient imaging, in the 1st cohort (n=3) showed little redistribution of 212Pb-TCMC-trastuzumab out of the peritoneal cavity. Compared to the early post-treatment images, the 18-hour post-injection images illustrated the shift to more uniform anterior/posterior abdominal distribution and the loss of intensity due to radioactive decay. Conclusion: Use of medium energy collimator, 15% width of 238.6 keV photopeak, and a 7.5% upper scatter window is adequate for quantification of 212Pb radioactivity inside peritoneal cavity for alpha radioimmunotherapy of ovarian cancer. Research Support: AREVA Med, NIH 1UL1RR025777-01.

60 APPLIED LIFE SCIENCES↗

Equation of state of nuclear matter in a virial expansion of nucleons and nuclei

We study the equation of state (EOS) of nuclear matter at subnuclear density in a virial expansion for a nonideal gas. The gas consists of neutrons, protons, alpha particles, and 8980 species of nuclei with A{>=}12 and masses from the finite-range droplet model. At very low density, the virial expansion reduces to nuclear statistical equilibrium. At higher density, the virial results match smoothly to the relativistic mean field results discussed in our previous paper. We tabulate the resulting EOS at over 73 000 grid points in the temperature range T=0.158 to 15.8 MeV, the density range n{sub B}=10{sup -8} to 0.1 fm{sup -3}, and the proton fraction range Y{sub P}=0.05 to 0.56. In the future we plan to match these low-density results to our earlier high-density mean field results, and generate a full EOS table for use in supernova and neutron star merger simulations. This virial EOS is exact in the low-density limit.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast-ions on Alcator C-Mod: Comparisons between Simulation and Experiment for Equilibrium and Evolving Distributions

Analysis of fast-ion distributions >100 T{sub e} is important for both ITER and a fusion reactor, as both will have a significant population of fusion-born alpha particles. Furthermore, energetic ions may display transport properties that differ from the bulk plasma. It is imperative to benchmark current simulation codes with measurements of highly energetic fast-ions on current devices. Experimental measurements of ICRF heated H-minority plasmas on Alcator C-Mod are performed with an upgraded Compact Neutral Particle Analyzer (CNPA). The CNPA consists of vertically-viewing photodiode detectors with viewing chords from r/a = {approx}0.18 to 0.6 and energies from 150 keV to 1.5 MeV. The CNPA measurements are compared to the output of a synthetic diagnostic that has been added to the Fokker-Planck solver CQL3D. CQL3D is coupled with the full-wave solver AORSA to evolve a self-consistent fast-ion distribution. Good agreement is obtained between simulation and experiment for fast ion distributions that are in steady-state (df/dt = 0). However, there are discrepancies between the experimental and simulated results for the time-dependent evolution of the fast-ion distribution. A possible explanation of the discrepancy is due to violation of certain assumptions of quasi-linear theory.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dose and dose averaged LET comparison of {sup 1}H, {sup 4}He, {sup 6}Li, {sup 8}Be, {sup 10}B, {sup 12}C, {sup 14}N, and {sup 16}O ion beams forming a spread-out Bragg peak

Purpose: Modern clinical accelerators are capable of producing ion beams from protons up to neon. This work compares the depth dose distribution and corresponding dose averaged linear energy transfer (LET) distribution, which is related to the biological effectiveness, for different ion beams ({sup 1}H, {sup 4}He, {sup 6}Li, {sup 8}Be, {sup 10}B, {sup 12}C, {sup 14}N, and {sup 16}O) using multi-energetic spectra in order to configure spread-out Bragg peaks (SOBP). Methods: Monte Carlo simulations were performed in order to configure a 5 cm SOBP at 8 cm depth in water for all the different ion beams. Physical dose and dose averaged LET distributions as a function of depth were then calculated and compared. The superposition of dose distribution of all ions is also presented for a two opposing fields configuration. Additional simulations were performed for {sup 12}C beams to investigate the dependence of dose and dose averaged LET distributions on target depth and size, as well as beam configuration. These included simulations for a 3 cm SOBP at 7, 10, and 13 cm depth in water, a 6 cm SOBP at 7 depth in water, and two opposing fields of 6 cm SOBP. Results: Alpha particles and protons present superior physical depth dose distributions relative to the rest of the beams studied. Dose averaged LET distributions results suggest higher biological effectiveness in the target volume for carbon, nitrogen and oxygen ions. This is coupled, however, with relatively high LET values--especially for the last two ion species--outside the SOBP where healthy tissue would be located. Dose averaged LET distributions for {sup 8}Be and {sup 10}B beams show that they could be attractive alternatives to {sup 12}C for the treatment of small, not deeply seated lesions. The potential therapeutic effect of different ion beams studied in this work depends on target volume and position, as well as the number of beams used. Conclusions: The optimization of beam modality for specific tumor cites remains an open question that warrants further investigation and clinically relevant results.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-656: Quantitative Analysis of Proton Boron Fusion Therapy (PBFT) in Various Conditions

Purpose: Three alpha particles are concomitant of proton boron interaction, which can be used in radiotherapy applications. We performed simulation studies to determine the effectiveness of proton boron fusion therapy (PBFT) under various conditions. Methods: Boron uptake regions (BURs) of various widths and densities were implemented in Monte Carlo n-particle extended (MCNPX) simulation code. The effect of proton beam energy was considered for different BURs. Four simulation scenarios were designed to verify the effectiveness of integrated boost that was observed in the proton boron reaction. In these simulations, the effect of proton beam energy was determined for different physical conditions, such as size, location, and boron concentration. Results: Proton dose amplification was confirmed for all proton beam energies considered (< 96.62%). Based on the simulation results for different physical conditions, the threshold for the range in which proton dose amplification occurred was estimated as 0.3 cm. Effective proton boron reaction requires the boron concentration to be equal to or greater than 14.4 mg/g. Conclusion: We established the effects of the PBFT with various conditions by using Monte Carlo simulation. The results of our research can be used for providing a PBFT dose database.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inspection of the objects on the sea floor by using 14 MeV tagged neutrons

Variety of objects found on the sea floor needs to be inspected for the presence of materials which represent the threat to the environment and to the safety of humans. We have demonstrated that the sealed tube 14 MeV neutron generator with the detection of associated alpha particles can be used underwater when mounted inside ROV equipped with the hydraulic legs and variety of sensors for the inspection of such objects for the presence of threat materials. Such a system is performing the measurement by using the NaI gamma detector and an API-120 neutron generator which could be rotated in order to maximize the inspected target volume. The neutron beam intensity during the 10-30 min. measurements is usually 1 x 10{sup 7} n/s in 4{pi}. In this report the experimental results for some of commonly found objects containing TNT explosive or its simulant are presented. The measured gamma spectra are dominant by C, O and Fe peaks enabling the determination of the presence of explosives inside the ammunition shell. Parameters influencing the C/O ratio are discussed in some details. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Angular momentum dependence of the nuclear level-density parameter around Z{approx}50

{alpha}-particle evaporation spectra and {gamma}-ray multiplicities were measured for various target-projectile systems corresponding to residual nuclei in the range of Z{sub R}=48-55 and with excitation energy in the range of 30-40 MeV. The high-energy part of the evaporation spectra were analyzed using the statistical model code PACE2 to derive values of the inverse level-density parameter (K). The K values were found to be in the range of 9.0-10.5 for all systems. Angular momentum dependence of the inverse level-density parameter was investigated using the {gamma}-ray multiplicity data. It is seen that there are strong variations in K as a function of angular momentum for many systems. Present results provide important input information for a systematic understanding of the statistical properties of nuclei at moderate excitation energies and angular momenta.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Relative Biologic Effects of Low-Dose-Rate {alpha}-Emitting {sup 227}Th-Rituximab and {beta}-Emitting {sup 90}Y-Tiuexetan-Ibritumomab Versus External Beam X-Radiation

Purpose: To determine the relative biologic effects (RBE) of {alpha}-particle radiation from {sup 227}Th-rituximab and of {beta}-radiation from {sup 90}Y-tiuexetan-ibritumomab (Zevalin) compared with external beam X-radiation in the Raji lymphoma xenograft model. Methods and Materials: Radioimmunoconjugates were administered intravenously in nude mice with Raji lymphoma xenografts at different levels of activity. Absorbed dose to tumor was estimated by separate biodistribution experiments for {sup 227}Th-rituximab and Zevalin. Tumor growth was measured two to three times per week after injection or X-radiation. Treatment-induced increase in growth delay to reach tumor volumes of 500 and 1,000 mm{sup 3}, respectively, was used as an end point. Results: The absorbed radiation dose-rate in tumor was slightly more than 0.1 Gy/d for the first week following injection of {sup 227}Th-rituximab, and thereafter gradually decreased to 0.03 Gy/d at 21 days after injection. For treatment with Zevalin the maximum dose-rate in tumor was achieved already 6 h after injection (0.2 Gy/d), and thereafter decreased to 0.01 Gy/d after 7 days. The relative biologic effect was between 2.5 and 7.2 for {sup 227}Th-rituximab and between 1 and 1.3 for Zevalin. Conclusions: Both at low doses and low-dose-rates, the {sup 227}Th-rituximab treatment was more effective per absorbed radiation dose unit than the two other treatments. The considerable effect at low doses suggests that the best way to administer low-dose-rates, {alpha}-emitting radioimmunoconjugates is via multiple injections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The anomalous currents in the front foils of the JET lost alpha diagnostic KA-2

We have examined the observed currents in the front foils of the JET Faraday cup lost alpha particle diagnostic KA-2. In particular, we have sought to understand the currents during Ohmic plasmas for which the ion flux at the detectors was initially assumed to be negligible. We have considered two sources of this current: plasma ions (both deuterium and impurity) in the vicinity of the detector (including charge exchange neutrals) and photoemission from scattered UV radiation. Based upon modeling and empirical observation, the latter source appears most likely and, moreover, seems to be applicable to the currents in the front foil during ELMy H-mode plasmas. A very thin gold or nickel foil attached to the present detector aperture is proposed as a solution to this problem, and realistic calculations of expected fluxes of lost energetic neutral beam ions during TF ripple experiments are presented as justification of this proposed solution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energetic ions in ITER plasmas

This paper discusses the behaviour and consequences of the expected populations of energetic ions in ITER plasmas. It begins with a careful analytic and numerical consideration of the stability of Alfvén Eigenmodes in the ITER 15 MA baseline scenario. The stability threshold is determined by balancing the energetic ion drive against the dominant damping mechanisms and it is found that only in the outer half of the plasma (r/a>0.5) can the fast ions overcome the thermal ion Landau damping. This is in spite of the reduced numbers of alpha-particles and beam ions in this region but means that any Alfvén Eigenmode-induced redistribution is not expected to influence the fusion burn process. The influence of energetic ions upon the main global MHD phenomena expected in ITER's primary operating scenarios, including sawteeth, neoclassical tearing modes and Resistive Wall Modes, is also reviewed. Fast ion losses due to the non-axisymmetric fields arising from the finite number of toroidal field coils, the inclusion of ferromagnetic inserts, the presence of test blanket modules containing ferromagnetic material, and the fields created by the Edge Localised Mode (ELM) control coils in ITER are discussed. The greatest losses and associated heat loads onto the plasma facing components arise due to the use of the ELM control coils and come from neutral beam ions that are ionised in the plasma edge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ION KINETIC ENERGY CONSERVATION AND MAGNETIC FIELD STRENGTH CONSTANCY IN MULTI-FLUID SOLAR WIND ALFVÉNIC TURBULENCE

We investigate the properties of plasma fluid motion in the large-amplitude, low-frequency fluctuations of highly Alfvénic fast solar wind. We show that protons locally conserve total kinetic energy when observed from an effective frame of reference comoving with the fluctuations. For typical properties of the fast wind, this frame can be reasonably identified by alpha particles which, due to their drift with respect to protons at about the Alfvén speed along the magnetic field, do not partake in the fluid low-frequency fluctuations. Using their velocity to transform the proton velocity into the frame of Alfvénic turbulence, we demonstrate that the resulting plasma motion is characterized by a constant absolute value of the velocity, zero electric fields, and aligned velocity and magnetic field vectors as expected for unidirectional Alfvénic fluctuations in equilibrium. We propose that this constraint, via the correlation between velocity and magnetic field in Alfvénic turbulence, is the origin of the observed constancy of the magnetic field; while the constant velocity corresponding to constant energy can only be observed in the frame of the fluctuations, the corresponding constant total magnetic field, invariant for Galilean transformations, remains the observational signature in the spacecraft frame of the constant total energy in the Alfvén turbulence frame.

79 ASTRONOMY AND ASTROPHYSICS↗

First record of single event upset on the ground, Cray-1 computer memory at Los Alamos in 1976

Records of bit flips in the Cray-1 computer installed at Los Alamos in 1976 lead to an upset rate in the Cray-1 's bipolar SRAMs that correlates with the SEUs being induced by the atmospheric neutrons. In 1976 the Cray Research Company delivered its first supercomputer, the Cray-1, installing it at Los Alamos National Laboratory. Los Alamos had competed with the Lawrence Livermore National Laboratory for the Cray-1 and won, reaching an agreement with Seymour Cray to install the machine for a period of six months for free, after which they could decide whether to buy, lease or return it. As a result, Los Alamos personnel kept track of the computer reliability and performance and so we know that during those six months of operation, 152 memory parity errors were recorded. The computer memory consisted of approximately 70,000 1Kx1 bipolar ECL static RAMs, the Fairchild 10415. What the Los Alamos engineers didn't know is that those bit flips were the result of single event upsets (SEUs) caused by the atmospheric neutrons. Thus, these 152 bit flips were the first recorded SEUs on the earth, and were observed 2 years before the SEUs in the Intel DRAMs that had been found by May and Woods in 1978. The upsets in the DRAMs were shown to have been caused by alpha particles from the chip packaging material. In this paper we will demonstrate that the Cray-1 bit flips, which were found through the use of parity bits in the Cray-1, were likely due to atmospheric neutrons. This paper will follow the same approach as that of the very first paper to demonstrate single event effects, which occurred in satellite flip-flop circuits in 1975. The main difference is that in the four events that occurred over the course of 17 satellite years of operation were shown to be due to single event effects just a few years after those satellite anomalies were recorded. In the case of the Cray-1 bit flips, there has been a delay of more than 30 years between the occurrence of the bit flips and the identification of their cause as SEUs induced by the atmospheric neutrons.

42 ENGINEERING↗

Glauber model for {alpha}-nucleus total reaction cross section

The Coulomb-modified Glauber model is employed to calculate the total reaction cross section ({sigma}{sub R}) for {alpha} particles from {sup 9}Be, {sup 12}C, {sup 16}O, {sup 28}Si, {sup 40}Ca, {sup 58,60}Ni, {sup 112,116,120,124}Sn, and {sup 208}Pb at 117.2, 163.9, and 192.4 MeV and from the lighter nuclei also at 69.6 MeV. Our main focus in this work is to assess the suitability of semiphenomenological parametrization of the NN amplitude (SPNN), used recently [Deeksha Chauhan and Z. A. Khan, Eur. Phys. J. A 41, 179 (2009)], in the analysis of {sigma}{sub R} at the energies under consideration. Using the realistic form factors for the colliding nuclei, it is found that the SPNN works reasonably well and we have quite a satisfactory account of the {sigma}{sub R} data in all the cases. Moreover, our analysis suggests that the SPNN could be taken as fairly stable to describe simultaneously the elastic angular distribution and the {sigma}{sub R} for a wide range of target nuclei in the relatively low-energy region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗