Search NASA⌕ Search

SEARCH · Search NASA

Results for “Arcing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Trajectory Modulated Arc Therapy: A Fully Dynamic Delivery With Synchronized Couch and Gantry Motion Significantly Improves Dosimetric Indices Correlated With Poor Cosmesis in Accelerated Partial Breast Irradiation

Purpose: To develop planning and delivery capabilities for linear accelerator–based nonisocentric trajectory modulated arc therapy (TMAT) and to evaluate the benefit of TMAT for accelerated partial breast irradiation (APBI) with the patient in prone position. Methods and Materials: An optimization algorithm for volumetrically modulated arc therapy (VMAT) was generalized to allow for user-defined nonisocentric TMAT trajectories combining couch rotations and translations. After optimization, XML scripts were automatically generated to program and subsequently deliver the TMAT plans. For 10 breast patients in the prone position, TMAT and 6-field noncoplanar intensity modulated radiation therapy (IMRT) plans were generated under equivalent objectives and constraints. These plans were compared with regard to whole breast tissue volume receiving more than 100%, 80%, 50%, and 20% of the prescription dose. Results: For TMAT APBI, nonisocentric collision-free horizontal arcs with large angular span (251.5 ± 7.9°) were optimized and delivered with delivery time of ∼4.5 minutes. Percentage changes of whole breast tissue volume receiving more than 100%, 80%, 50%, and 20% of the prescription dose for TMAT relative to IMRT were −10.81% ± 6.91%, −27.81% ± 7.39%, −14.82% ± 9.67%, and 39.40% ± 10.53% (P≤.01). Conclusions: This is a first demonstration of end-to-end planning and delivery implementation of a fully dynamic APBI TMAT. Compared with IMRT, TMAT resulted in marked reduction of the breast tissue volume irradiated at high doses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gallium composition dependence of crystallographic and thermoelectric properties in polycrystalline type-I Ba{sub 8}Ga{sub x}Si{sub 46-x} (nominal x=14-18) clathrates prepared by combining arc melting and spark plasma sintering methods

The gallium composition dependence of crystallographic and thermoelectric properties in polycrystalline n-type Ba{sub 8}Ga{sub x}Si{sub 46-x} (nominal x=14-18) compounds with the type-I clathrate structure is presented. Samples were prepared by combining arc melting and spark plasma sintering methods. Powder x-ray diffraction, Rietveld analysis, scanning electron microscopy, and energy-dispersive x-ray spectroscopy show that the solubility limit of gallium in the type-I clathrate phase is close to x=15, which is slightly higher than that for a single crystal. The carrier concentration at room temperature decreases from 2 Multiplication-Sign 10{sup 21} cm{sup -3} to 4 Multiplication-Sign 10{sup 20} cm{sup -3} as the Ga content x increases. The Seebeck coefficient, the electrical conductivity, and the thermal conductivity vary systematically with the carrier concentration when the Ga content x varies. The effective mass (2.0m{sub 0}), the carrier mobility (10 cm{sup 2} V{sup -1} s{sup -1}), and the lattice thermal conductivity (1.1 W m{sup -1} K{sup -1}) are determined for the Ga content x=14.51. The dimensionless thermoelectric figure of merit ZT is about 0.55 at 900 K for the Ga content x=14.51. The calculation of ZT using the experimentally determined material parameters predicts ZT=0.8 (900 K) at the optimum carrier concentration of about 2 Multiplication-Sign 10{sup 20} cm{sup -3}. - Graphical abstract: The gallium composition dependence of crystallographic and thermoelectric properties is presented on polycrystalline n-type Ba{sub 8}Ga{sub x}Si{sub 46-x} with the type-I clathrate structure prepared by combining arc melting and spark plasma sintering methods. The thermoelectric figure of merit ZT reaches 0.55 at 900 K due to the increase in the Ga content (close to x=15), and a calculation predicts further improvement of ZT at the optimized carrier concentration. Highlights: Black-Right-Pointing-Pointer Crystallographic properties of Ba{sub 8}Ga{sub x}Si{sub 46-x} clathrates are characterized. Black-Right-Pointing-Pointer Arc melting and spark plasma sintering process enables increase of Ga content. Black-Right-Pointing-Pointer We elucidate the Ga composition dependence of thermoelectric properties. Black-Right-Pointing-Pointer Thermoelectric figure of merit ZT is improved due to the increased Ga content. Black-Right-Pointing-Pointer Calculation predicts a potential ZT=0.8 at 900 K at optimized carrier concentration.

36 MATERIALS SCIENCE↗

Corrosion behaviour of magnesium alloys coated with TiN by cathodic arc deposition in NaCl and Na{sub 2}SO{sub 4} solutions

Magnesium-based light-metal alloys belong to a class of structural materials with increasing industrial attention. Magnesium alloys show the lowest density among the engineering metallic materials, low cost and large availability. However, the limitations according to mechanical strength and the low corrosion resistance restrict their practical application. In this study, TiN was coated on magnesium-based AZ91 magnesium-aluminium-zinc alloy using cathodic arc PVD process. The corrosion behaviours of uncoated and coated magnesium alloys in 1% NaCl, 3% NaCl and 3% Na{sub 2}SO{sub 4} solutions and the influence of the coatings on the corrosion behaviour of the substrate were investigated utilizing potentiodynamic polarization tests. A potentiostat for electrochemical corrosion tests, a cathodic arc physical vapour deposition coating system for coating processes, a scanning electron microscopy for surface examination and elemental analysis of the coatings were used in this study. It was determined that corrosion resistance of magnesium alloys can be increased with TiN coating on the alloys using cathodic arc PVD process.

36 MATERIALS SCIENCE↗

Measurement of anode surface temperature in carbon nanomaterial production by arc discharge method

Highlights: • We measured the temperature of anode surface by two-color pyrometry combined with a high speed camera successfully. • Growth temperature of pyrolytic graphite, MWNTs, and nano-graphite particles were in ranges of 2400–2600 K, 2600–2700 K, and 2700–3500 K, respectively. • High temperature contributes to form thermodynamically unstable material. - Abstract: Nano-graphite particles, multi-wall carbon nanotube (MWNT), and pyrolytic graphite were prepared at different positions of the anode surface in an arc discharge. Graphite electrodes were employed for the arc discharge under helium environment at atmospheric pressure. Nano-sized carbon products were characterized by scanning electron microscopy and transmission electron microscopy. During the arc discharge, two-color pyrometry combined with a high-speed camera was conducted to measure the temperature distribution of the anode surface. The growth temperature of pyrolytic graphite, MWNT, and nano-graphite particles were in the ranges of 2400–2600 K, 2600–2700 K, and 2700–3500 K, respectively. The local temperature of anode surface is a critical parameter to determine the products with different morphologies. The formation mechanism of these carbon nanomaterials is suggested based on the local temperature of anode surface and their thermodynamic stability.

36 MATERIALS SCIENCE↗

HybridArc: A novel radiation therapy technique combining optimized dynamic arcs and intensity modulation

This investigation focuses on possible dosimetric and efficiency advantages of HybridArc-a novel treatment planning approach combining optimized dynamic arcs with intensity-modulated radiation therapy (IMRT) beams. Application of this technique to two disparate sites, complex cranial tumors, and prostate was examined. HybridArc plans were compared with either dynamic conformal arc (DCA) or IMRT plans to determine whether HybridArc offers a synergy through combination of these 2 techniques. Plans were compared with regard to target volume dose conformity, target volume dose homogeneity, sparing of proximal organs at risk, normal tissue sparing, and monitor unit (MU) efficiency. For cranial cases, HybridArc produced significantly improved dose conformity compared with both DCA and IMRT but did not improve sparing of the brainstem or optic chiasm. For prostate cases, conformity was improved compared with DCA but not IMRT. Compared with IMRT, the dose homogeneity in the planning target volume was improved, and the maximum doses received by the bladder and rectum were reduced. Both arc-based techniques distribute peripheral dose over larger volumes of normal tissue compared with IMRT, whereas HybridArc involved slightly greater volumes of normal tissues compared with DCA. Compared with IMRT, cranial cases required 38% more MUs, whereas for prostate cases, MUs were reduced by 7%. For cranial cases, HybridArc improves dose conformity to the target. For prostate cases, dose conformity and homogeneity are improved compared with DCA and IMRT, respectively. Compared with IMRT, whether required MUs increase or decrease with HybridArc was site-dependent.

61 RADIATION PROTECTION AND DOSIMETRY↗

Intensity-modulated radiation therapy and volumetric-modulated arc therapy for adult craniospinal irradiation—A comparison with traditional techniques

Craniospinal irradiation (CSI) poses a challenging planning process because of the complex target volume. Traditional 3D conformal CSI does not spare any critical organs, resulting in toxicity in patients. Here the dosimetric advantages of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) are compared with classic conformal planning in adults for both cranial and spine fields to develop a clinically feasible technique that is both effective and efficient. Ten adult patients treated with CSI were retrospectively identified. For the cranial fields, 5-field IMRT and dual 356° VMAT arcs were compared with opposed lateral 3D conformal radiotherapy (3D-CRT) fields. For the spine fields, traditional posterior-anterior (PA) PA fields were compared with isocentric 5-field IMRT plans and single 200° VMAT arcs. Two adult patients have been treated using this IMRT technique to date and extensive quality assurance, especially for the junction regions, was performed. For the cranial fields, the IMRT technique had the highest planned target volume (PTV) maximum and was the least efficient, whereas the VMAT technique provided the greatest parotid sparing with better efficiency. 3D-CRT provided the most efficient delivery but with the highest parotid dose. For the spine fields, VMAT provided the best PTV coverage but had the highest mean dose to all organs at risk (OAR). 3D-CRT had the highest PTV and OAR maximum doses but was the most efficient. IMRT provides the greatest OAR sparing but the longest delivery time. For those patients with unresectable disease that can benefit from a higher, definitive dose, 3D-CRT–opposed laterals are the most clinically feasible technique for cranial fields and for spine fields. Although inefficient, the IMRT technique is the most clinically feasible because of the increased mean OAR dose with the VMAT technique. Quality assurance of the beams, especially the junction regions, is essential.

61 RADIATION PROTECTION AND DOSIMETRY↗

Volumetric-modulated arc therapy in postprostatectomy radiotherapy patients: A planning comparison study

The purpose of this study was to compare postprostatectomy planning for volumetric-modulated arc therapy (VMAT) with both single arc (SA) and double arcs (DA) against dynamic sliding window intensity-modulated radiotherapy (IMRT). Ten cases were planned with IMRT, SA VMAT, and DA VMAT. All cases were planned to achieve a minimum dose of 68 Gy to 95% of the planning target volume (PTV) and goals to limit rectal volume >40 Gy to 35% and >65 Gy to 17%, and bladder volumes >40 Gy to 50% and >65 Gy to 25%. Plans were averaged across the 10 patients and compared for mean dose, conformity, homogeneity, rectal and bladder doses, and monitor units. The mean dose to the clinical target volume and PTV was significantly higher (p<0.05) for SA compared with DA or IMRT. The homogeneity index was not significantly different: SA = 0.09; DA = 0.08; and IMRT = 0.07. The rectal V40 was lowest for the DA plan. The rectal V20 was significantly lower (p<0.05) for both the VMAT plans compared with IMRT. There were no significant differences for bladder V40 or rectal and bladder V65. The IMRT plans required 1400 MU compared with 745 for DA and 708 for SA. This study shows that for equivalent dose coverage, SA and DA VMAT plans result in higher mean doses to the clinical target volume and PTV. This greater dose heterogeneity is balanced by improved low-range rectal doses and halving of the monitor units.

61 RADIATION PROTECTION AND DOSIMETRY↗

Implementation of a volumetric modulated arc therapy treatment planning solution for kidney and adrenal stereotactic body radiation therapy

To develop a volumetric modulated arc therapy (VMAT) treatment planning solution in the treatment of primary renal cell carcinoma and oligometastatic adrenal lesions with stereotactic body radiation therapy. Single-arc VMAT plans (n = 5) were compared with clinically delivered step-and-shoot intensity-modulated radiotherapy (IMRT) with planning target volume coverage normalized between techniques. Target volume conformity, organ-at-risk (OAR) dose, treatment time, and monitor units were compared. A VMAT planning solution, created from a combination of arc settings and optimization constraints, auto-generated treatment plans in a single optimization. The treatment planning solution was evaluated on 15 consecutive patients receiving kidney and adrenal stereotactic body radiation therapy. Treatment time was reduced from 13.0 ± 2.6 to 4.0 ± 0.9 minutes for IMRT and VMAT, respectively. The VMAT planning solution generated treatment plans with increased target homogeneity, improved 95% conformity index, and a reduced maximum point dose to nearby OARs but with increased intermediate dose to distant OARs. The conformity of the 95% isodose improved from 1.32 ± 0.39 to 1.12 ± 0.05 for IMRT and VMAT treatment plans, respectively. Evaluation of the planning solution showed clinically acceptable dose distributions for 13 of 15 cases with tight conformity of the prescription isodose to the planning target volume of 1.07 ± 0.04, delivering minimal dose to OARs. The introduction of a stereotactic body radiation therapy VMAT treatment planning solution improves the efficiency of planning and delivery time, producing treatment plans of comparable or superior quality to IMRT in the case of primary renal cell carcinoma and oligometastatic adrenal lesions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Photon optimizer (PO) vs progressive resolution optimizer (PRO): a conformality- and complexity-based comparison for intensity-modulated arc therapy plans

This study aimed to provide guidance on the advantages and limitations of a new optimizer, “photon optimizer” (PO), when compared with its predecessor, “progressive resolution optimizer” (PRO), for intensity-modulated arc therapy (IMAT) plans. Eleven study plans that included a cohort of prostate, head and neck, and brain treatment sites were optimized using both PRO and PO algorithms. A plan template using the same objectives for the same number of iterations was used for each optimized plan to obtain hypothetical treatment plans that would be comparable with a clinical plan. Analysis was performed using plan conformity-based parameters such as target volume coverage factor, conformation number and homogeneity indices, and plan complexity assessment parameters such as small aperture score, modulation indices, and monitor unit variation with arc angle for prostate, brain and head, and neck IMAT treatment plans. Plan conformality analysis demonstrated that conformation numbers, target volume coverage factors, and homogeneity indices produced by the 2 optimizers were comparable for most anatomic sites. IMAT treatment plans produced using the PRO optimizer were found to be less complex than plans produced using the PO optimizer, in terms of multileaf collimator (MLC) leaf position variability and modulation complexity scores. Similarly, the PRO optimizer was shown to produce treatment plans that used fewer monitor units (and generally fewer monitor unit per degree of arc rotation) than PO optimizer. This study demonstrated that the PO optimizer can produce IMAT treatment plans with a similar degree of dose conformity to the target volume and generally improved organ at risk sparing, compared with the PRO optimizer. Better coverage to organs at risk produced by plans optimized using PO was observed to have higher MLC variability and monitor units. Therefore, careful evaluation of treatment plan conformity and complexity before assessing its deliverability is recommended when implementing the routine use of PO optimizer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Anatomy of a diffracting detonation in a circular arc of explosive

Using high-resolution numerical simulation, study diffraction of a detonation as it traverses a 270° finite-thickness condensed-phase explosive arc. This geometry admits a steady solution in a frame rotating with angular speed ω 0 , which thereby facilitates a detailed analysis of how the loss of energy from the detonation reaction zone due to the diffraction process slows the propagation of the detonation. There exists a region of subsonic flow, between the detonation shock and the curve of sonic flow (labelled the DDZ), which is responsible for setting ω 0 . Although the DDZ spans the entire thickness for thin arcs, it is localized to a region near the inside surface as the arc is thickened. Furthermore the explosive energy release near this inside surface plays a disproportionate role in the diffraction process.

42 ENGINEERING↗

Spontaneous combustion prediction of coal by C80 and ARC techniques

Many coal fires were caused by spontaneous combustion in coal mines or coal storehouses, which resulted in a great loss and energy wastage. To identify and evaluate the hazardous degree of coal stockpile, a C80 microcalorimeter and accelerating rate calorimeter (ARC) were employed in this work. The coal samples undergo an exothermal process start at 80 {sup o}C with heat generation of -75.1 J g{sup -1} (mean value) detected by C80 experiment. The activation energies of the first exothermal process were calculated for the three experiments, and the mean value is 80.76 kJ mol{sup -1}, which is lower than that of obtained from the ARC result, 127.0 kJ mol{sup -1}. For a 300 tons coal stockpile, the self-heating oxidation temperatures (SHOT) were calculated as 164, 60, 90, and 68{sup o}C based on the ARC experiment and three C80 experiments, respectively. Further research on the mass effect on SHOT shows that if the coal mass is less than 12 tons, the danger of thermal spontaneous combustion is less. However, if the mass amount is more than 12000 tons, the danger of thermal spontaneous combustion is difficult to avoid even at ambient temperature if no special measures are taken. 38 refs., 9 figs.

01 COAL, LIGNITE, AND PEAT↗

First Simultaneous Observation of STEVE and SAR Arc Combining Data From Citizen Scientists, 630.0 nm All‐Sky Images, and Satellites

Abstract On September 28, 2017 citizen scientist observations at Alberta, Canada (51°N, 113° W) detected aurora and a thin east‐west purplish arc, known as strong thermal emission velocity enhancement (STEVE) that lasted less than 20 min. All‐sky imagers at subauroral latitudes measured stable auroral red (SAR) arcs during the entire night. The imager at Bridger, MT (45.3°N, 108.9°W) also measured a STEVE. The overlapping geometry allowed to determine that the height of STEVE was 225–275 km. STEVE is brighter in the 630.0 nm images in the West and almost merges with the SAR arc in the East. A DMSP satellite pass in the southern hemisphere was at the conjugate location of the Bridger imager during the STEVE observation. When mapped into the northern hemisphere intense subauroral ion drift and subauroral polarization streams were detected associated with the two optical signatures measured in 630.0 nm.

Martinis, C.↗

Energy Transport and Conversion Above a Bright Discrete Auroral Arc

Magnetically connected observations of particle distributions and luminosity from the Reimei spacecraft are used to examine energy transport and conversion occurring above a discrete auroral arc. By combining imaging and in situ measurements it is shown how transverse electromagnetic and kinetic energy fluxes measured along the spacecraft trajectory converge across geomagnetic field-lines into the acceleration region. It is shown how cross-field energy transport is facilitated by the formation of vortices along the length of the arc. From an integration over the vertical extent of the acceleration region it is shown that the transverse and field-aligned flow of energy into the arc locally supports the dissipation needed to power the electron acceleration observed. Estimates of gradients in electromagnetic and kinetic energy flows show how field-aligned electron energization in the acceleration region is supported by the divergence of Poynting flux along and across the background magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Prediction of an arc-tunable Weyl Fermion metallic state in Mo x W 1-x Te 2

A Weyl semimetal is a new state of matter that hosts Weyl fermions as emergent quasiparticles. The Weyl fermions correspond to isolated points of bulk band degeneracy, Weyl nodes, which are connected only through the crystal’s boundary by exotic Fermi arcs. The length of the Fermi arc gives a measure of the topological strength, because the only way to destroy the Weyl nodes is to annihilate them in pairs in the reciprocal space. To date, Weyl semimetals are only realized in the TaAs class. Here, we propose a tunable Weyl state in Mo x W 1₋x Te 2 where Weyl nodes are formed by touching points between metallic pockets. We show that the Fermi arc length can be changed as a function of Mo concentration, thus tuning the topological strength. Lastly,our results provide an experimentally feasible route to realizing Weyl physics in the layered compound Mo x W 1₋x Te 2 , where non-saturating magneto-resistance and pressure-driven superconductivity have been observed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Weyl Fermion semimetal with surface Fermi arcs in the transition metal monopnictide TaAs class

Weyl fermions are massless chiral fermions that play an important role in quantum field theory but have never been observed as fundamental particles. A Weyl semimetal is an unusual crystal that hosts Weyl fermions as quasiparticle excitations and features Fermi arcs on its surface. Such a semimetal not only provides a condensed matter realization of the anomalies in quantum field theories but also demonstrates the topological classification beyond the gapped topological insulators. Here, we identify a topological Weyl semimetal state in the transition metal monopnictide materials class. Our first-principles calculations on TaAs reveal its bulk Weyl fermion cones and surface Fermi arcs. Our results show that in the TaAs-type materials the Weyl semimetal state does not depend on fine-tuning of chemical composition or magnetic order, which opens the door for the experimental realization of Weyl semimetals and Fermi arc surface states in real materials.

Science & Technology - Other Topics↗

Dirac node arcs in PtSn 4

In topological quantum materials 1,2,3 the conduction and valence bands are connected at points or along lines in the momentum space. A number of studies have demonstrated that several materials are indeed Dirac/Weyl semimetals 4,5,6,7,8 . However, there is still no experimental confirmation of materials with line nodes, in which the Dirac nodes form closed loops in the momentum space 2,3 . Here we report the discovery of a novel topological structure—Dirac node arcs—in the ultrahigh magnetoresistive material PtSn 4 using laser-based angle-resolved photoemission spectroscopy data and density functional theory calculations. Unlike the closed loops of line nodes, the Dirac node arc structure arises owing to the surface states and resembles the Dirac dispersion in graphene that is extended along a short line in the momentum space. Here, we propose that this reported Dirac node arc structure is a novel topological state that provides an exciting platform for studying the exotic properties of Dirac fermions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental observation of topological Fermi arcs in type-II Weyl semimetal MoTe2

Weyl semimetal is a new quantum state of matter hosting the condensed matter physics counterpart of the relativistic Weyl fermions originally introduced in high-energy physics. The Weyl semimetal phase realized in the TaAs class of materials features multiple Fermi arcs arising from topological surface states and exhibits novel quantum phenomena, such as a chiral anomaly-induced negative magnetoresistance and possibly emergent supersymmetry. Recently it was proposed theoretically that a new type (type-II) of Weyl fermion that arises due to the breaking of Lorentz invariance, which does not have a counterpart in high-energy physics, can emerge as topologically protected touching between electron and hole pockets. In this work, we report direct experimental evidence of topological Fermi arcs in the predicted type-II Weyl semimetal MoTe 2 (refs 23-25). Additionally, the topological surface states are confirmed by directly observing the surface states using bulk- and surface-sensitive angle-resolved photoemission spectroscopy, and the quasi-particle interference pattern between the putative topological Fermi arcs in scanning tunnelling microscopy. By establishing MoTe 2 as an experimental realization of a type-II Weyl semimetal, our work opens up opportunities for probing the physical properties of this exciting new state.

36 MATERIALS SCIENCE↗

Electron cyclotron resonance ion sources with arc-shaped coils

The minimum-B magnetic field structure of electron cyclotron resonance ion sources (ECRIS) has conventionally been formed with a combination of solenoids and a hexapole magnet. However, minimum-B structure can also be formed with arc-shaped coils. Recently it was shown that multiply charged heavy-ions can be produced with an ECRIS based on such a structure. In the future, the ARC-ECRIS magnetic field structure can be an interesting option for radioactive ion-beam sources and charge-breeders as well as for high performance ECRIS allowing for 100 GHz plasma heating. This paper presents some design aspects of the ARC-ECRIS.

43 PARTICLE ACCELERATORS↗