Search NASA⌕ Search

SEARCH · Search NASA

Results for “Barrow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36

Solar wind control of Jupiter's hectometric radio emission

Radio, plasma, and magnetic field data obtained by Voyager 1 and Voyager 2 were used to examine the manner in which the Jovian hectometric radio emission (HOM) is controlled by the solar wind. Using the method of superposed epochs, it was found that the higher energy HOM is correlated with the IMF as well as with the solar wind density and pressure. However, unlike the Io-independent decametric radio emission (Non-Io DAM), the HOM displayed no correlation with the solar wind velocity, although this radio component appear to be also influenced by the IMF. The results suggest separate HOM amd Non-Io DAM sources.

Barrow, C. H.↗

Baryogenesis in extended inflation. 2: Baryogenesis via primordial black holes

Baryogenesis at the end of extended inflation is studied. Extended inflation is brought to an end by the collisions of bubble walls surrounding regions of true vacuum, a process which produces particles well out of thermal equilibrium. The possibility that the wall collisions may provide a significant density of primordial black holes is considered and their possible role in generating a baryon asymmetry is examined.

Barrow, John D.↗

An outgassing model of non-metallic materials for the ascent of a Titan 4 launch vehicle

Outgassing of nonmetallic materials and components inside Titan IV's 2A compartment during ascent may present a problem to the payload community in relation to molecular deposition and degradation of sensitive payload surfaces. The procedure currently being developed to model the amounts, transport, and deposition of outgassed molecular contaminants onto a payload's sensitive surface consists of three phases. The first phase involves the development of a thermogravimetric method that recreates the increasing temperature and decreasing pressure profiles expected in the 2A compartment of the TIV launch vehicle during ascent. The second phase involves the determination of deposition rates of outgassed materials onto a payload surface, and the subsequent evaporation rate as a function of temperature of deposited material. The third phase takes the temperature and pressure profiles from phase one, the deposition and evaporation rates and kinetic coefficients determined in phase two, and incorporates them into the SPACE II computer program to determine which payload surfaces are most susceptible to molecular deposition from TIV's outgassing sources, and the level of permanent deposition expected on those surfaces.

Barrows, R. D.↗

Evaluation of noninvasive cardiac output methods during exercise

Noninvasive techniques to estimate cardiac output (Qc) will be used during future space flight. This retrospective literature survey compared the Qc techniques of carbon dioxide rebreathing (CO2-R), CO2 single breath (CO2-S), Doppler (DOP), impedance (IM), and inert gas (IG: acetylene or nitrous oxide) to direct (DIR) assessments measured at rest and during exercise.

Moore, Alan D.↗

Fuel utilization during exercise after 7 days of bed rest

Energy yield from carbohydrate, fat, and protein during physical activity is partially dependent on an individual's fitness level. Prolonged exposure to microgravity causes musculoskeletal and cardiovascular deconditioning; these adaptations may alter fuel utilization during space flight. Carbohydrate and fat metabolism during exercise were analyzed before and after 7 days of horizontal bed rest.

Barrows, Linda H.↗

Eccentric and concentric muscle performance following 7 days of simulated weightlessness

Changes in skeletal muscle strength occur in response to chronic disuse or insufficient functional loading. The purpose of this study was to examine changes in muscle performance of the lower extremity and torso prior to and immediately after 7 days of simulated weightlessness (horizontal bed rest). A Biodex was used to determine concentric and eccentric peak torque and angle at peak torque for the back, abdomen, quadriceps, hamstring, soleus, and tibialis anterior. A reference angle of 0 degrees was set at full extension. Data were analyzed by ANOVA.

Hayes, Judith C.↗

Radio observations of the Jovian magnetic field

Radio observations of Jupiter are reviewed and discussed in relation to the planet's magnetic field. Early ground-based decameter- and decimeter-wave observations lead to a first estimate of the magnetic field strength which was subsequently confirmed by space-borne measurements. Decametric, hectometric and decimetric measurements of the Jovian rotation period offer the possibility of detecting a real change in the magnetic field structure within the next few decades. Solar wind control of the radio emission allows inferences to be made concerning the magnetic field and the emission regions at decametric, hectometric and kilometric frequencies. The decametric and the hectometric radiation may originate in hollow-cone emission sources at high (auroral) latitudes on Jupiter. The broad-band kilometric emission appears to originate at the outer edge of the Io torus.

Barrow, C. H.↗

Physiological responses to wearing the space shuttle launch and entry suit and the prototype advanced crew escape suit compared to the unsuited condition

The launch and entry suit (LES) is a life support suit worn during Orbiter ascent and descent. The impact of suit weight and restricted mobility on egress from the Orbiter during an emergency is unknown. An alternate suit - the advanced crew escape suite (ACES) - is being evaluated. The physiological responses to ambulatory exercise of six subjects wearing the LES and ACES were measured and compared to those measurements taken while unsuited. Dependent variables included heart rate and metabolic response to treadmill walking at 5.6 km/h (3.5 mph), and also bilateral concentric muscle strength about the knee, shoulder, and elbow. No significant (p greater than 0.06) differences in heart rate or metabolic variables were measured in either suit while walking at 5.6 km/h. Significant (p less than 0.05) decreases in all metabolic variables were remarked when both suits were compared to the unsuited condition. There were no significant (p greater than 0.05) differences among the three suit conditions at 30 or 180 deg/s for muscles about the elbow and knee; however, about the shoulder, a significant (p = 0.0215) difference between the ACES and the unsuited condition was noted. Therefore, wearing a life support suit while performing Orbiter egress imposes a significant metabolic demand on crewmembers. Selective upper body strength movements may be compromised.

Barrows, Linda H.↗

Comparison of total body water estimates from O-18 and bioelectrical response prediction equations

Identification of an indirect, rapid means to measure total body water (TBW) during space flight may aid in quantifying hydration status and assist in countermeasure development. Bioelectrical response testing and hydrostatic weighing were performed on 27 subjects who ingested O-18, a naturally occurring isotope of oxygen, to measure true TBW. TBW estimates from three bioelectrical response prediction equations and fat-free mass (FFM) were compared to TBW measured from O-18. A repeated measures MANOVA with post-hoc Dunnett's Test indicated a significant (p less than 0.05) difference between TBW estimates from two of the three bioelectrical response prediction equations and O-18. TBW estimates from FFM and the Kushner & Schoeller (1986) equation yielded results that were similar to those given by O-18. Strong correlations existed between each prediction method and O-18; however, standard errors, identified through regression analyses, were higher for the bioelectrical response prediction equations compared to those derived from FFM. These findings suggest (1) the Kushner & Schoeller (1986) equation may provide a valid measure of TBW, (2) other TBW prediction equations need to be identified that have variability similar to that of FFM, and (3) bioelectrical estimates of TBW may prove valuable in quantifying hydration status during space flight.

Barrows, Linda H.↗

Variability of prediction of maximal oxygen concumption on the cycle ergometer using standard equations

Several investigations within the Exercise Countermeasures Project at the NASA Johnson Space Center focused on the assessment of maximum oxygen consumption (VO2(sub max)) within the Astronaut Corps pre- and postspace flight. Investigations during the Apollo era suggested that there was a significant decrease in postflight VO2(sub max) when compared to preflight values, and current studies have documented that this trend continues in the Space Shuttle era. It is generally accepted and was confirmed in our laboratory that VO2(sub max) can be predicted from submaximal measures taken during graded exercise tests on the cycle ergometer with respect to populations. However, previous work had not examined the effect of day-to-day variations in the physiologic responses that might alter these predictions for individuals. Stability of individual submaximal data over serial tests is important so that predicted changes in VO2(sub max) are reflective of actual VO2(sub max) changes. Therefore, the purpose of this investigation was to determine which of the accepted equations to predict VO2(sub max) would be less affected by normal daily physiologic changes.

Greenisen, Michael C.↗

Fluid-loading solutions and plasma volume: Astro-ade and salt tablets with water

Fluid loading with salt and water is a countermeasure used after space flight to restore body fluids. However, gastrointestinal side effects have been frequently reported in persons taking similar quantities of salt and water in ground-based studies. The effectiveness of the Shuttle fluid-loading countermeasure (8 gms salt, 0.97 liters of water) was compared to Astro-ade (an isotonic electrolyte solution), to maintain plasma volume (PV) during 4.5 hrs of resting fluid restriction. Three groups of healthy men (n=6) were studied: a Control Group (no drinking), an Astro-ade Group, and a Salt Tablet Group. Changes in PV after drinking were calculated from hematocrit and hemoglobin values. Both the Salt Tablet and Astro-ade Groups maintained PV at 2-3 hours after ingestion compared to the Control Group, which had a 6 percent decline. Side effects (thirst, stomach cramping, and diarrhea) were noted in at least one subject in both the Astro-ade and Salt Tablet Groups. Nausea and vomiting were reported in one subject in the Salt Tablet Group. It was concluded that Astro-ade may be offered as an alternate fluid-loading countermeasure but further work is needed to develop a solution that is more palatable and has fewer side effects.

Fortney, Suzanne M.↗

Broadband, High-Temperature Ultrasonic Transducer

Materials chosen for endurance at high temperatures and acoustic coupling and damping. Acoustic transducer designed to exhibit broad frequency response and to survive temperatures close to melting points of brazing alloys. Attached directly and continuously to hot object monitored ultrasonically: for example, it can be attached to relatively cool spot on workpiece during brazing for taking ultrasonic quality-control measurements.

Parker, F. Raymond↗

Electronic Ambient-Temperature Recorder

Electronic temperature-recording unit stores data in internal memory for later readout. Records temperatures from minus 40 degrees to plus 60 degrees C at intervals ranging from 1.875 to 15 minutes. With all four data channels operating at 1.875-minute intervals, recorder stores at least 10 days' data. For only one channel at 15-minute intervals, capacity extends to up to 342 days' data. Developed for recording temperatures of instruments and life-science experiments on satellites, space shuttle, and high-altitude aircraft. Adaptable to such terrestrial uses as recording temperatures of perishable goods during transportation and of other systems or processes over long times. Can be placed directly in environment to monitor.

Russell, Larry↗

Determining Aerodynamic Loads Based on Optical Deformation Measurements

This paper describes a videogram metric technique for determining aerodynamic loads based on optical elastic deformation measurements. The data reduction methods are developed to extract the normal force and pitching moment from beam deformation data. The axial force is obtained by measuring the axial translational motion of a movable shaft in a spring/bearing device. Proof-of-concept calibration experiments are conducted to assess the accuracy of this optical technique.

Liu, Tianshu↗

Determining Aerodynamic Loads Based on Optical Deformation Measurements

This paper describes a videogrammetric technique for determining aerodynamic loads based on optical elastic deformation measurements. The data reduction methods are developed to extract the normal force and pitching moment from beam deformation data. The axial force is obtained by measuring the axial translational motion of a movable shaft in a spring/bearing device. Proof-of-concept calibration experiments are conducted to assess the accuracy of this optical technique.

Liu, Tianshu↗

Assessing Videogrammetry for Static Aeroelastic Testing of a Wind-Tunnel Model

The Videogrammetric Model Deformation (VMD) technique, developed at NASA Langley Research Center, was recently used to measure displacements and local surface angle changes on a static aeroelastic wind-tunnel model. The results were assessed for consistency, accuracy and usefulness. Vertical displacement measurements and surface angular deflections (derived from vertical displacements) taken at no-wind/no-load conditions were analyzed. For accuracy assessment, angular measurements were compared to those from a highly accurate accelerometer. Shewhart's Variables Control Charts were used in the assessment of consistency and uncertainty. Some bad data points were discovered, and it is shown that the measurement results at certain targets were more consistent than at other targets. Physical explanations for this lack of consistency have not been determined. However, overall the measurements were sufficiently accurate to be very useful in monitoring wind-tunnel model aeroelastic deformation and determining flexible stability and control derivatives. After a structural model component failed during a highly loaded condition, analysis of VMD data clearly indicated progressive structural deterioration as the wind-tunnel condition where failure occurred was approached. As a result, subsequent testing successfully incorporated near- real-time monitoring of VMD data in order to ensure structural integrity. The potential for higher levels of consistency and accuracy through the use of statistical quality control practices are discussed and recommended for future applications.

Spain, Charles V.↗

Optical Measurement Technique for Space Column Characterization

A simple optical technique for the structural characterization of lightweight space columns is presented. The technique is useful for determining the coefficient of thermal expansion during cool down as well as the induced strain during tension and compression testing. The technique is based upon object-to-image plane scaling and does not require any photogrammetric calibrations or computations. Examples of the measurement of the coefficient of thermal expansion are presented for several lightweight space columns. Examples of strain measured during tension and compression testing are presented along with comparisons to results obtained with Linear Variable Differential Transformer (LVDT) position transducers.

Barrows, Danny A.↗

Comparing the effects of two in-flight aerobic exercise protocols on standing heart rates and VO(2peak) before and after space flight

The effects of regular aerobic exercise on orthostatic tolerance have been the subject of a long-standing controversy that will influence the use of exercise during space flight. To examine these effects, astronauts performed continuous (CE) aerobic exercise (n = 8), interval (IE) aerobic exercise (n = 4), or no (NE) exercise (n = 5) during flights of 7 to 11 days. Heart rate (HR) responses to an orthostatic challenge (stand test) were measured 10 days before flight and on landing day. VO(2peak) (graded treadmill exercise) was measured 7 to 21 days before and 2 days after flight. No significant differences across the groups were observed in standing HRs before or after flight. However, the within-group mean HRs significantly increased in the NE (71-89 beats/min) and CE (60-85 beats/min) groups after space flight. The HRs for the IE group did not significantly increase (75-86 beats/min) after space flight. VO(2peak) decreased (P < .05) in the NE (-9.5%) group, but did not change in the CE (-2.4%) and IE (1%) groups. The relationship (r = 0.237) between the delta HR and delta VO(2peak) was not significant. These preliminary results indicate that: (1) continuous exercise does not affect the orthostatic HR response after space flight; (2) interval exercise may minimize an increase in the postflight orthostatic HR; and (3) both exercise protocols can maintain VO(2peak).

NASA Discipline Musculoskeletal↗