Pressure and current balance conditions during electron beam injections from spacecraft

Electrostatic charging level of a conducting surface in response to injections of electron beams into space plasma is investigated by means of one-dimensional Vlasov code. Injections of Maxwellian beams into a vacuum shows that the surface can charge up to an electric potential phi sub s greater than W sub b, where W sub b is the average electron beam energy. Since Maxwellian beams have extended trails with electrons having energies greater than W sub b, it is difficult to quantify the charging level in terms of the energies of the injected electrons. In order to quantitatively understand the charging in excess of W sub b, simulations were carried out for water-bag types of beam with velocity distribution functions described by f(V) = A for V sub min approx. less than V approx. less than V sub max and f(V) = O otherwise, where A is a constant making the normalized beam density unity. It is found that V sub max does not directly determine the charging level. The pressure distribution in the electron sheath determines the electric field distribution near the surface. The electric field in turn determines the electrostatic potential of the vehicle. The pressure distribution is determined by the beam parameters such as the average beam velocity and the velocity spread of the beam.

Hwang, K. S.↗

Electron energy distributions measured during electron beam/plasma interactions

In the large vacuum facility at the NASA-Johnson Space Center an electron beam was projected 20 m parallel to B from a gun with variable accelerating potential (1.0 to 2.5 kV) to an aluminum target. The ionospheric neutral pressure and field were approximated. Beam electron energy distributions were measured directly using an electrostatic deflection analyzer and indirectly with a detector that responded to the X-rays produced by electron impact on the target. At low currents the distribution is sharply peaked at the acceleration potential. At high currents a beam plasma discharge occurs and electrons are redistributed in energy so that the former energy peak broadens to 10-15 percent FWHM with a strongly enhanced low energy tail. At the 10% of maximum point the energy spectrum ranges from less than 1/2 to 1.2 times the gun energy. The effect is qualitatively the same at all pitch angles and locations sampled.

Jost, R. J.↗

Using solenoid as multipurpose tool for measuring beam parameters

Solenoids are frequently used for focusing low-energy beams. In this paper, we show how they can serve as multipurpose diagnostics tools to measure various beam parameters, including energy, emittance, the second moments of the transverse distribution, and the beam position and angle with respect to the solenoid’s axis. The energy measurement is based on rotation of the plane of the transverse motion, as opposed to generating dispersion with a dipole. Measurement of the beam trajectory with respect to the solenoid axis is done by analyzing the beam orbit downstream of the solenoid while varying its current. The second moments are calculated by analyzing the beam image on a profile monitor while accounting for the beam rotation caused by the solenoid. We describe in detail the corresponding procedures and the experimental results of these measurements.

43 PARTICLE ACCELERATORS↗

A probe for real-time images of particle beams and their analyses in a merged-beams apparatus

A real-time charged particle beam probe was developed, which can be used both as a beam diagnostic (beam tuning) and to quantitatively determine the three-dimensional density distribution of a beam. The probe consists of a microchannel plate, an aluminized phosphor screen deposited on a fiber-optic faceplate, a flexible fiber-optic bundle, and a charge injection device (CID) in tandem. Digital or analog video output of the CID is fed into a computer or oscilloscope, respectively, for analysis or observation. The probe can be moved continuously along the beams' paths to obtain 'pictures' of the beam at any desired interval, thus giving three-dimensional form factors. The beams, singly or simultaneously, may be observed on the monitor facilitating the task of beam adjustment for optimum overlap. The digital output is used for quantitative computation of the beam overlaps. The device is linear with beam intensity, but the performance degrades with time due to beam damage of the microchannel plate.

Forand, J. L.↗

High resolution energy analyzer for broad ion beam characterization

Characterization of the ion energy distribution function (IEDF) of low energy high current density ion beams by conventional retarding field and deflection type energy analyzers is limited due to finite ion beam emittance and beam space charge spreading inside the analyzer. These deficiencies are, to a large extent, overcome with the recent development of the variable-focusing retarding field energy analyzer (RFEA), which has a cylindrical focusing electrode preceding the planar retarding grid. The principal concept of this analyzer is conversion of a divergent charged particle beam into a quasiparallel beam before analyzing it by the planar retarding field. This allows analysis of the beam particle total kinetic energy distribution with greatly improved energy resolution. Whereas this concept was first applied to analyze 5-10 keV pulsed electron beams, the present authors have adapted it to analyze the energy distribution of a low energy ({<=}1 KeV) broad ion beam. In this paper we describe the RFEA design, which was modified from the original, mainly as required by the specifics of broad ion beam energy analysis, and the device experimental characterization and modeling results. Among the modifications, an orifice electrode placed in front of the RFEA provides better spatial resolution of the broad ion beam ion optics emission region and reduces the beam plasma density in the vicinity of analyzer entry. An electron repeller grid placed in front of the RFEA collector was found critical for suppressing secondary electrons, both those incoming to the collector and those released from its surface, and improved energy spectrum measurement repeatability and accuracy. The use of finer mesh single- and double-grid retarding structures reduces the retarding grid lens effect and improves the analyzer energy resolution and accuracy of the measured spectrum mean energy. However, additional analyzer component and configuration improvements did not further change the analyzed IEDF shape or mean energy value. This led us to conclude that the optimized analyzer construction provides an energy resolution considerably narrower than the investigated ion beam energy spectrum full width at half maximum, and the derived energy spectrum is an objective and accurate representation of the analyzed broad ion beam energy distribution characteristics. A quantitative study of the focusing voltage and retarding grid field effects based on the experimental data and modeling results have supported this conclusion.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generalized Kapchinskij-Vladimirskij Distribution and Envelope Equation for High-intensity Beams in a Coupled Transverse Focusing Lattice

In an uncoupled lattice, the Kapchinskij-Vladimirskij (KV) distribution function first analyzed in 1959 is the only known exact solution of the nonlinear Vlasov-Maxwell equations for high- intensity beams including self-fields in a self-consistent manner. The KV solution is generalized here to high-intensity beams in a coupled transverse lattice using the recently developed generalized Courant-Snyder invariant for coupled transverse dynamics. This solution projects to a rotating, pulsating elliptical beam in transverse configuration space, determined by the generalized matrix envelope equation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a compact thermal lithium atom beam source for measurements of electron velocity distribution function anisotropy in electron cyclotron resonance plasmas

The anisotropy of the electron velocity distribution function (EVDF) in plasmas can be deduced from the polarization of emissions induced by anisotropic electron-impact excitation. In this paper, we develop a compact thermal lithium atom beam source for spatially resolved measurements of the EVDF anisotropy in electron cyclotron resonance (ECR) plasmas. The beam system is designed such that the ejected beam has a slab shape, and the beam direction is variable. The divergence and flux of the beam are evaluated by experiments and calculations. The developed beam system is installed in an ECR plasma device with a cusp magnetic field, and the LiI 2s–2p emission (670.8 nm) is observed in low-pressure helium plasma. The two-dimensional distributions of the degree and direction of the polarization in the LiI emission are measured by a polarization imaging system. The evaluated polarization distribution suggests the spatial variation of the EVDF anisotropy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantum noise in optical interferometers

We study the photon counting noise in optical interferometers used for gravitational wave detection. In order to reduce quantum noise, a squeezed vacuum is injected into the usually unused input port. It is investigated under which conditions the gravitational wave signal may be amplified without increasing counting noise concurrently. Such a possibility was suggested as a consequence of the entanglement of the two output ports of a beam splitter. We find that amplification without concurrent increase of noise is not possible for reasonable squeezing parameters. Photon distributions for various beam splitter angles and squeezing parameters are calculated.

74 ATOMIC AND MOLECULAR PHYSICS↗

Development of a strongly focusing high-intensity He{sup +} ion source for a confined alpha particle measurement at ITER

A strongly focusing high-intensity He{sup +} ion source has been designed and constructed as a beam source for a high-energy He{sup 0} beam probe system for diagnosis of fusion produced alpha particles in the thermonuclear fusion plasmas. The He{sup +} beam was extracted from the ion source at an acceleration voltage of 18-35 kV. Temperature distributions of the beam target were observed with an IR camera. The 1/e-holding beam profile half-width was about 15 mm at optimum perveance (Perv) of 0.03 (I{sub beam}=2.4 A). A beam current about 3 A was achieved at an acceleration voltage of 26.7 kV with an arc power of 10 kW (Perv=0.023)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Angular distribution of emitted electrons due to intense p-polarized laser foil interaction

The angular distribution of electrons emitting from a foil surface illuminated by p-polarized laser pulses is studied using particle-in-cell simulation for incident angles of theta{sub 1}=22.5 deg., 45 deg., 67.5 deg. and laser amplitudes of a=0.5, 1, 2. Theoretical prediction of the emission direction, based on canonical momentum conservation along the target surface, is verified. Surface ablation, the Alfven current limit, as well as self-generated electromagnetic fields on the surface are numerically investigated and found to play important roles in the modulation of the angular distribution of the emitted electrons. The emitted electrons of higher energy are found to be directly accelerated to near the polarization direction of the incident laser light. The simulation results agree very well with the recent experimental results from Al targets irradiated by a 60 fs, 180 mJ laser pulse.

74 ATOMIC AND MOLECULAR PHYSICS↗

Observation of three dimensional optical rogue waves through obstacles

We observe three-dimensional rogue waves in the speckle distribution of a spatially modulated optical beam. Light is transmitted beyond a partially reflecting obstacle generating optical rogue waves at a controlled position in the shadow of the barrier. When the barrier transmits only 0.07% of the input laser power, we observe the mostly localized event. These results demonstrate that an optimum amount of spatial non-homogeneity maximizes the probability of a gigantic event while the technique we exploit enables to control light behind a fully reflective wall.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-D-BRE-06: Modeling the Dosimetric Effects of Volumetric and Layer-Based Repainting Strategies in Spot Scanning Proton Treatment Plans

Purpose: To compare multiple repainting techniques as strategies for mitigating the interplay effect in free-breathing, spot scanning proton plans. Methods: An analytic routine modeled three-dimensional dose distributions of pencil-beam proton plans delivered to a moving target. The interplay effect was studied in subsequent calculations by modeling proton delivery from a clinical synchrotron based spot scanning system and respiratory target motion, patterned from surrogate breathing traces from clinical 4DCT scans and normalized to nominal 0.5 and 1 cm amplitudes. Two distinct repainting strategies were modeled. In idealized volumetric repainting, the plan is divided up and delivered multiple times successively, with each instance only delivering a fraction of the total MU. Maximum-MU repainting involves delivering a fixed number of MU per spot and repeating a given energy layer until the prescribed MU are reached. For each of 13 patient breathing traces, the dose was computed for up to four volumetric repaints and an array of maximum-MU values. Delivery strategies were inter-compared based on target coverage, dose homogeneity, and delivery time. Results: Increasing levels of repainting generally improved plan quality and reduced dosimetric variability at the expense of longer delivery time. Motion orthogonal to the scan direction yielded substantially greater dose deviations than motion parallel to the scan direction. For a fixed delivery time, maximum-MU repainting was most effective relative to idealized volumetric repainting at small maximum-MU values. For 1 cm amplitude motion orthogonal to the scan direction, the average homogeneity metric (D5 – D95)[%] of 23.4% was reduced to 7.6% with a 168 s delivery using volumetric repainting compared with 8.7% in 157.2 s for maximum-MU repainting. The associated static target homogeneity metric was 2.5%. Conclusion: Maximum-MU repainting can provide a reasonably effective alternative to volumetric repainting for systems without the capability to switch energies rapidly.

60 APPLIED LIFE SCIENCES↗

Comparison of observed and theoretical Fe L emission from CIE plasmas

We analyze data from the Lawrence Livermore National Lab (LLNL) Electron Beam Ion Trap (EBIT) that simulates a CIE plasma by sweeping the electron beam to approximate a Maxwellian velocity distribution. These results are compared to spectra of confirmed astronomical CIE plasmas (e.g. outer regions of x-ray clusters) observed by XMM/RGS. We utilize the Photon Clean Method (PCM) to quantify these spectra (EBIT and XMM/RGS) in the form of ratios of Fe L lines in the emission complex near 1 keV. The variances of line fluxes are measured with bootstrap methods (Efron 1979). Both of these observations are further compared with theoretical predictions of Fe L line fluxes from APED and similar atomic databases.

99 GENERAL AND MISCELLANEOUS↗

Anomalous auroral electron distributions due to an artificial ion beam in the ionosphere

Results are reported for the perturbation of the auroral ionosphere by the operation of an ion gun which injected about 100 mA of 25-eV Ar(+) ions at upgoing pitch angles over a discrete auroral arc. The major effects observed were the excitation of intense broadband electric field fluctuations at zero-10 kHz, and the appearance of streaming and isotropic heating in different parts of superthermal electron velocity space. A scenario is explored in which electron runaway or streaming is expected between the trapping speed and the critical velocity for cyclotron interactions with the waves, where the streaming electrons carry the current that would be carried by thermals or energetic electrons in the absence of the waves. A current of about 1.0 microA/sq m is carried by the streaming electrons. The gun-associated electrons were anomalous in the sense that their anisotropy was the opposite of that observed in the natural aurora.

Moore, T. E.↗

Beam imaging sensor

The present invention relates generally to the field of sensors for beam imaging and, in particular, to a new and useful beam imaging sensor for use in determining, for example, the power density distribution of a beam including, but not limited to, an electron beam or an ion beam. In one embodiment, the beam imaging sensor of the present invention comprises, among other items, a circumferential slit that is either circular, elliptical or polygonal in nature.