Tightening McCormick Relaxations Toward Global Solution of the ACOPF Problem

Here, we show that a strong upper bound on the objective of the alternating current optimal power flow (ACOPF) problem can significantly improve the effectiveness of optimization-based bounds tightening (OBBT) on a number of relaxations. We additionally compare the performance of relaxations of the ACOPF problem, including the rectangular form without reference bus constraints, the rectangular form with reference bus constraints, and the polar form. We find that relaxations of the rectangular form significantly strengthen existing relaxations if reference bus constraints are included. Overall, relaxations of the polar form perform the best. However, neither the rectangular nor the polar form dominates the other. Ultimately, with these strategies, we are able to reduce the optimality gap to less than 0.1% on all but 5 NESTA test cases with up to 300 buses by performing OBBT alone.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Deliverable Flexible Ramping Products Considering Spatiotemporal Correlation of Wind Generation and Demand Uncertainties

Flexible ramping products (FRPs) have been implemented by several independent system operators (ISOs) to procure adequate flexible resources. Currently, system operators estimate the system level ramping requirements ignoring the spatiotemporal correlations among various uncertainty sources. This leads to overestimates/underestimates of ramping requirements. In addition, the explicit FRPs model considers only the generation ramping limitation. Other security constraints, such as the transmission limits, are not considered, which leads to deliverability issues of FRPs. To deal with these shortcomings of current FRPs models, this paper proposes a deliverable FRPs based on a distributionally-robust chance constrained multi-interval optimal power flow (DRCC-MIOPF) considering the spatiotemporal correlation of wind power and demand uncertainties endogenously. Furthermore, an asymmetrical affine policy (AAP) is proposed to leverage generation flexibility and mitigate the uncertainty in different directions. The pricing mechanism of the FRPs is proposed using a novel uncertainty-contained locational marginal price (U_LMP) which is derived from the proposed AAP-DRCC-MIOPF model. New components representing the price of FRPs are added into the traditional LMP formulation. Finally, the PJM 5-bus, IEEE 39-bus and IEEE 118-bus systems case studies validate the proposed FRPs approach. The payment of uncertain demand and wind power on FRPs are analyzed.

electricity market↗

A robust dynamic state estimation approach against model errors caused by load changes

Dynamic state estimation (DSE) plays an important role in power system security monitoring and online control. In practice, there are two approaches to implementing DSE. The first approach is distributed DSE, which is based on the assumption that the terminal bus of each generator can be measured by PMUs (phasor measurement units). The assumption cannot be satisfied currently, however, because PMUs usually are installed at important high-voltage buses such as 500-kV buses installed in portions of the grid overseen by the Western Electricity Coordinating Council. Another issue of this approach is that performance of DSE is vulnerable to bad measurement data. The reason for this vulnerability is that DSE is performed separately through measurements at each terminal bus, and measurements at terminal buses are the only measurement upon which DSE can rely. Therefore, important redundant measurements are not included in this approach. The second approach is centralized DSE. This approach does not have the requirement for PMU location, and redundant measurements can be considered fully. However, load changes and grid topology changes impact centralized DSE. In this paper, we propose a new approach for handling the impact of load changes on DSE. We have developed a new algorithm that includes two sequential steps. In the first step, errors caused by load changes are detected by analyzing the difference between prediction results and measured results. In the second step, once model error is detected, a model optimization procedure is run to correct the error so the state estimation error can be mitigated. Simulation results from the IEEE 68 bus system show that the proposed approach can effectively handle model errors caused by load changes.

robust dynamic state estimation, load change, powe↗

Contingency Analysis Based on Partitioned and Parallel Holomorphic Embedding

In the steady-state contingency analysis, the traditional Newton-Raphson method suffers from non-convergence issues when solving post-outage power flow problems, which hinders the integrity and accuracy of security assessment. In this paper, we propose a novel robust contingency analysis approach based on holomorphic embedding (HE). Here, the HE-based simulator provides theoretical convergence guarantee, which is desirable because it avoids the influence of numerical issues and provides a credible security assessment conclusion. In addition, based on the multi-area characteristics of real-world power systems, a partitioned HE (PHE) method is proposed with an interfacebased partitioning of HE formulation. The PHE method does not undermine the numerical robustness of HE and significantly reduces the computation burden in large-scale contingency analysis. The PHE method is further enhanced by parallel or distributed computation to become parallel PHE (P2HE). Tests on a 458-bus system, a synthetic 419-bus system and a large-scale 21447-bus system demonstrate the advantages of the proposed methods in robustness and efficiency.

42 ENGINEERING↗

Distribution Grid Modeling Using Smart Meter Data

The knowledge of distribution grid models, including topologies and line impedances, is essential for grid monitoring, control and protection. However, such information is often unavailable, incomplete or outdated. The increasing deployment of smart meters (SMs) provides a unique opportunity to tackle this issue. This paper proposes a two-stage framework for distribution grid modeling using SM data. In the first stage, the network topology is identified by reconstructing a weighted Laplacian matrix of distribution networks. In the second stage, a least absolute deviations (LAD) regression model is developed for estimating line impedance of a single branch based on the nonlinear (inverse) power flow model, wherein a conductor library is leveraged to narrow down the solution space. The LAD regression model is originally a mixed-integer nonlinear program whose continuous relaxation is still non-convex. Furthermore, we specially address its convex relaxation and discuss the exactness. The modified regression model is then embedded within a bottom-up sweep algorithm to achieve the identification across the network in a branch-wise manner. Numerical results on the IEEE 13-bus, 37-bus and 69-bus test feeders validate the effectiveness of the proposed methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Generalized Analytical Estimation of Sensitivity Matrices in Unbalanced Distribution Networks

Fast and accurate estimation of sensitivity matrices is significant for the enhancement of distribution system modeling and automation. Analytical estimations have mainly focused on voltage magnitude sensitivity to active/reactive power injections for unbalanced networks with Wye-connected loads and neglecting DERs' smart inverter functionality. Hence, this paper enhances the scope of analytical estimation of sensitivity matrices for unbalanced networks with 1- Φ, 2- Φ, and 3- Φ Delta/Wye-connected loads, DERs with smart inverter functionality, and substation/line step-voltage regulators (SVR). A composite bus model comprising of DER, Delta- and Wye-connected load is proposed to represent a generic distribution bus, which can be simplified to load, PV, or voltage-controlled bus as required. Furthermore, the proposed matrix-based analytical method consolidates voltage magnitude and angle sensitivity to active/reactive power injection and tap-position of all SVRs into a single algorithm. Extensive case studies on IEEE and EPRI networks show the accuracy and wide scope of the proposed algorithm compared to the existing benchmark method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Scalable Risk Assessment of Rare Events in Power Systems With Uncertain Wind Generation and Loads

Risk assessment of rare events has become increasingly important in power system planning and operation with the increasing integration of renewable energy and the presence of system uncertainties. However, quantifying the risk posed by rare events via the traditional method, i.e., Monte Carlo sampling (MCS), incurs substantial computational expense stemming from the vast ensemble of power flow simulations. To accelerate the assessment, this paper proposes a Deep Neural Network (DNN)-kernelized vector-valued Gaussian Process (VVGP) approach with excellent computational efficiency while maintaining high accuracy. Consequently, serving as a surrogate model for the power flow solver, the DNN-kernelized VVGP enables significantly faster but accurate risk assessment compared to the power flow solver. The developed surrogate model evaluates low-order N - k events that contain more than 90% instances by adeptly capturing the topological features while the high-order N - k events are assessed via a power flow solver, thereby striking a balance between computational efficiency and uncertainty quantification accuracy. Moreover, the model incorporates a Support Vector Machine (SVM) classifier to resample concerning low-probability tail events to counteract the biases potentially introduced during the DNN-kernelized VVGP evaluations. Simulations conducted on the modified IEEE 24-bus, 118-bus, and European 1354-bus systems demonstrate that the proposed method maintains the accuracy benchmark set by MCS while significantly reducing computational demands in large-scale power systems as compared to other state-of-the-art methods.

17 WIND ENERGY↗

A Two-Stage Quantum Reinforcement Learning Method for Multi-Objective Transmission Switching

Multi-objective transmission switching (MO-TS) problems involve the strategic reconfiguration of network topology to simultaneously optimize multiple objectives. As the system scale increases, finding feasible solutions becomes increasingly challenging due to the problem's nonlinearity and high computational complexity. To address these challenges, this paper proposes a two-stage quantum reinforcement learning method that leverages potential quantum advantages for MO-TS. In the first stage, candidate switching lines are identified using a graph-theoretical approach to reduce the problem's dimensionality. The second stage introduces a quantum-classical reinforcement learning framework, where a learnable measurement-based CNN-ResVQC architecture is developed to effectively reduce the input dimension for quantum processing, mitigate vanishing gradients, and enhance trainability while improving the quantum circuit's flexibility in modeling complex decision policies for MO-TS. Numerical studies on IEEE 14-bus, 57-bus, and 118-bus systems demonstrate that the proposed algorithm achieves superior training stability and faster convergence with approximately 1% of the network parameters required by classical algorithms, highlighting its effectiveness, efficiency, and scalability. Furthermore, the practicality is validated through its stable convergence under three common quantum noise channels.

99 GENERAL AND MISCELLANEOUS↗

Distribution System State Estimation: A Semidefinite Programming Approach

Distribution system state estimation (DSSE) is one of the vital components in the next-generation distribution management system which allows operators to monitor the entire system's operating conditions. Due to the lack of real-time measurements, DSSE has to process measurements whose quality varies significantly across different sources, which causes a convergence issue to the Gauss-Newton solver. In this paper, a semidefinite programming (SDP) framework is proposed to reformulate the DSSE problem into a rank- constrained SDP problem. One challenge of this technique is the nonconvex rank-one constraint, which is generally relaxed. However, the relaxed SDP-DSSE problem cannot guarantee a rank-one solution and hence loses optimality. Therefore, we propose two solution approaches to obtain rank-one solutions for the SDPDSSE problem: the rank reduction approach and the convex iteration approach. The model and the effectiveness of the proposed solution approaches are numerically demonstrated on the IEEE 13-bus, 34-bus, and 123-bus distribution systems.

convex iteration↗

Optimal D-FACTS Placement in Moving Target Defense Against False Data Injection Attacks

Moving target defense (MTD) is a defense strategy to detect stealthy false data injection (FDI) attacks against the power system state estimation using distributed flexible AC transmission system (D-FACTS) devices. However, existing studies neglect to address a fundamental yet critical issue, i.e., the D-FACTS placement, by assuming that all lines are equipped with D-FACTS devices. Here, to tackle this problem, we first derive analytical necessary conditions and requirements on the D-FACTS placement for a complete MTD. Further, we propose sufficient conditions using a graph theory-based topology analysis to ensure that the MTD under the proposed D-FACTS placement has the maximum rank of its composite matrix, which is indicative of the MTD effectiveness. Based on the analytical conditions, we design D-FACTS placement algorithms by using the minimum number of D-FACTS devices to achieve the maximum MTD effectiveness. A novel MTD-based ACOPF model, in which the reactance of D-FACTS lines is introduced as decision variables, is proposed to find a trade-off between the system loss and the MTD effectiveness. Numerical results on 6-bus, IEEE 14-bus, and IEEE 118-bus systems show the efficacy of MTDs using the proposed D-FACTS placement algorithms in maximizing the composite matrix rank and detecting FDI attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Voltage Stability Constrained Moving Target Defense Against Net Load Redistribution Attacks

Moving target defense (MTD) using distributed flexible AC transmission system (D-FACTS) devices is a promising defense strategy to detect stealthy false data injection (FDI) attacks against the power system state estimation. However, all existing studies myopically perturb the reactance of D-FACTS lines without considering the system voltage stability. In this paper, we first illustrate voltage instability induced by MTDs in a three-bus system. To address this issue, we further propose a novel MTD framework that explicitly considers system voltage stability by using continuation power flow and voltage stability indices. We mathematically derive the sensitivity matrix of voltage stability index to line impedance, on which an optimization problem for maximizing voltage stability index is formulated. This framework is tested on the IEEE 14-bus and the IEEE 118-bus transmission systems, in which net load redistribution attacks are launched by sophisticated attackers. Here, the simulation results show the effectiveness of the proposed framework in circumventing the voltage instability while maintaining the detection effectiveness of MTD. We conduct case studies with and without the proposed framework under different MTD planning and operational methods. The impacts of the proposed two methods on attack detection effectiveness and system economic metrics are also revealed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Economic Analysis of On-Route Fast Charging for Battery Electric Buses: Case Study in Utah

Battery electric buses (BEBs) are increasingly being embraced by transit agencies as an energy-efficient and emission-free alternative to bus fleets. However, because of the limitations of battery technology, BEBs suffer from limited driving range, great battery cost, and time-consuming charging processes. On-route fast charging technology is gaining popularity as a remedy, reducing battery cost, extending driving range, and reducing charging time. With on-route fast charging, BEBs are as capable as their diesel counterparts in relation to range and operating time. However, transit agencies may have the following concerns about on-route fast charging: 1) on-route fast charging stations require massive capital costs; 2) on-route fast charging may lead to high electricity power demand charges; and 3) charging during peak hours may increase electricity energy charges. This study conducts a quantitative economic analysis of on-route fast charging for BEBs, thereby providing some guidelines for transit agencies. An integrated optimization model is first proposed to determine battery size, charger type, and recharging schedule for a general BEB route. Based on the model, an economic analysis of on-route fast charging is then performed on 10 real-world bus routes and a simplified general bus route with different parameters. The results demonstrate that given the current prices of on-route fast charging stations and batteries, it is always beneficial to install on-route fast charging stations for BEBs. A sensitivity analysis is also conducted to show the impact of potential price reductions of batteries.

Engineering↗

Development of in-use engine speed/torque heat maps across multiple heavy-duty commercial vehicle vocations

The U.S. Department of Energy (DOE) established the SuperTruck program with the goal of achieving brake thermal efficiency (BTE) greater than or equal to 55% as demonstrated in an operational heavy-duty (HD) diesel engine at a 65-miles-per-hour (mph) cruise point. Beyond the line-haul application, HD engines operate in a wide range of speed and torque conditions that are unlikely to yield the same efficiency under real-world operation. Thereby, the in-use engine heat maps described in this paper are a valuable tool to illustrate whether the engine-efficiency “sweet spot” matches the most frequent operating conditions. In this study, NREL developed engine heat maps to quantify the important operating points for various vocations using our Fleet DNA database of commercial fleet vehicle operations data. These heat maps clearly show that high-frequency operating points vary significantly according to vehicle vocation, while only a few of them match the sweet spot. Beyond the illustration, engine in-use heat maps can also be leveraged to build up reduced-order engine-efficiency models, needed by many rapid powertrain simulations. As case studies, nine reduced-order models – including line-haul truck, transfer truck, transit bus, transit bus with compressed natural gas (CNG) engine, drayage, refuse pickup, local delivery, utility truck, and school bus with CNG engine – using a trust-region reflective algorithm to fit the on-road data extracted based on the engine in-use heat maps.

33 ADVANCED PROPULSION SYSTEMS↗

Multiplexed color centers in a silicon photonic cavity array

Entanglement distribution is central to the modular scaling of quantum processors and establishing quantum networks. Color centers with telecom-band transitions and long spin coherence times are suitable candidates for long-distance entanglement distribution. However, high-bandwidth memory-enhanced quantum communication is limited by high-yield, scalable creation of efficient spin-photon interfaces. Here, we develop a silicon photonics platform consisting of arrays of bus-coupled cavities. The coupling to a common bus waveguide enables simultaneous access to individually addressable cavity-enhanced T center arrays. We demonstrate frequency-multiplexed operation of two T centers in separate photonic crystal cavities. In addition, we investigate the cavity enhancement of a T center through hybridized modes formed between physically distant cavities. Our results show that bus-coupled arrays of cavity-enhanced color centers could enable efficient on-chip and long-distance entanglement distribution.

Komza, Lukasz↗

UNAP DCM Theory of Operations

The UNAP DCM board is capable of measuring currents with a dynamic range of 3 x 10 -14 A to 3 x 10 -4 A. The design of the DCM closely matches the proven N-1 minigrand family DCM design. The most significant difference is the replacement of the Actel FPGA with an SPI I/O expander. The original DCM design used an Actel FPGA to communicate with the processor over the expansion bus controling the DCM gain and filtering. The UNAP processor communicates with the UDA FPGA over the cPCI bus. The UNAP DCM control functions are accomplished in the UDA FPGA and communicated to the DCM board via an SPI bus.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Assessment of Brine Management for Geologic Carbon Sequestration

Geologic carbon sequestration (GCS) is the injection of carbon dioxide (CO 2 ), typically captured from stationary emission sources, into deep geologic formations to prevent its entry into the atmosphere. Active pilot facilities run by regional United States (US) carbon sequestration partnerships inject on the order of one million metric tonnes (mt) CO 2 annually while the US electric power sector emits over 2000 million mt-CO 2 annually. GCS is likely to play an increasing role in US carbon mitigation initiatives, but scaling up GCS poses several challenges. Injecting CO 2 into sedimentary basins raises fluid pressure in the pore space, which is typically already occupied by naturally occurring, or native, brine. The resulting elevated pore pressures increase the likelihood of induced seismicity, of brine or CO 2 escaping into potable groundwater resources, and of CO 2 escaping into the atmosphere. Brine extraction is one method for pressure management, in which brine in the injection formation is brought to the surface through extraction wells. Removal of the brine makes room for the CO 2 and decreases pressurization. Although the technology required for brine extraction is mature, this form of pressure management will only be applicable if there are cost-­effective and sustainable methods of disposing of the extracted brine. Brine extraction, treatment, and disposal may increase the already substantial capital, energy, and water demands of Carbon dioxide Capture and Sequestration (CCS). But, regionally specific brine management strategies may be able to treat the extracted water as a source of revenue, energy, and water to subsidize CCS costs, while minimizing environmental impacts. By this approach, value from the extracted water would be recovered before disposing of any resulting byproducts. Until a price is placed on carbon, we expect that utilities and other CO 2 sources will be reluctant to invest in capital intensive, high risk GCS projects; early technical, economic, and environmental assessments of brine management are extremely valuable for determining the potential role of GCS in the US. We performed a first order feasibility and economic assessment, at three different locations in the US, of twelve GCS extracted-­water management options, including: geothermal energy extraction, desalination, salt and mineral harvesting, rare-­earth element harvesting, aquaculture, algae biodiesel production, road de-­icing, enhanced geothermal system (EGS) recharge, underground reinjection, landfill disposal, ocean disposal, and evaporation pond disposal. Three saline aquifers from different regions of the US were selected as hypothetical GCS project sites to encompass variation in parameters that are relevant to the feasibility and economics of brine disposal. The three aquifers are the southern Mt. Simon Sandstone Formation in the Illinois Basin, IL; the Vedder Formation in the southern San Joaquin Basin, CA; and the Jasper Interval in the eastern Texas Gulf Basin, TX. These aquifers are candidates for GCS due to their physical characteristics and their close proximity to large CO 2 emission sources. Feasibility and impacts were calculated using one mt-­CO 2 injected as the functional unit of brine management. Scenarios were performed for typical 1000MW coal-­fired power plants (CFPP) that incurred an assumed 24 percent carbon capture energy penalty (EP), injected 90 percent of CO 2 emissions (~9 million mt-­ CO 2 injected annually), and treated extracted water onsite. Net present value (NPV), land requirements, laws and regulations, and technological limits were determined for each stage of disposal, and used to estimate feasibility. The boundary of the assessment began once extracted water was brought to the surface, and ended once the water evaporated, was injected underground, or was discharged into surface water bodies. Results of the assessment were generated, stored, and analyzed using Microsoft Excel spreadsheets and ESRI Geographical Information System (GIS) maps. Conclusions about the relative benefits and impacts of alternative brine-­management strategies were highly sensitive to local climate and weather, and aquifer water chemistry. The NPV of certain scenarios ranged from -­$50/mt-­CO 2 (a cost) to +$10/mt-­CO 2 (revenue). The land footprint of the scenarios in this study ranged from <1 km 2 to 100 km 2 . Brine extraction as a pressure management tool for GCS has potential for improving the economics and for minimizing the environmental impacts of CCS. In order to maximize this potential, careful analysis of each saline aquifer and region must be conducted to determine a regionally appropriate brine use sequence (BUS) at the time of site selection. Models that use GIS will be essential tools in determining such sequences for individual CFPP. Future studies that perform risk and life cycle assessments (LCA) of BUS scenarios, incorporate additional impact metrics into the BUS model, and enhance the temporal sensitivity of the model would improve the robustness of this regional assessment method.

54 ENVIRONMENTAL SCIENCES↗

EGSim - a C++ Toolkit for Analysis of Power Grid Systems

We describe the load flow formulation and the solution algorithms available in the Electric power Grid Simulator (EGSim) software toolkit. EGSim contains tools aimed at simulating static load flow solutions for electric power grids. It parses power grid models described in IEEE Common Data Format, and generates solutions for the bus voltages and voltage angles, and real and reactive power values through the transmission lines. The software, written in C++, implements both Gauss-Seidel and Newton solution methods. Example results for the 118 bus models and 300 bus models are also presented.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Control Oriented Models for Co-Design: Technical Overview of MT HVDC, MVDC, and Solid State Transformer Building Blocks

The electric power system is shifting toward a power electronics–enabled grid, where converter based “building blocks” (e.g., high voltage direct current (HVDC) links, multi terminal HVDC (MT HVDC) networks, medium voltage DC (MVDC) links, and solid state transformers (SSTs)) provide fast, precise control of power flows, voltage, and frequency. This report develops and applies publicly shareable electromagnetic transient (EMT) and phasor models to examine how such building blocks can be composed and coordinated to support offshore wind integration, inter area transfers, feeder support, and resilience. Section 2 documents a modular multilevel converter (MMC)–based MT HVDC modeling framework and two use cases: a compact WSCC/IEEE 9 bus test system and a 240 bus “mini WECC” case with five offshore wind plants (OWFs). Phasor to EMT transfer, initialization, and sanity checks are summarized, and neutral demonstrations of normal and contingency operation are reported. Section 3 frames the problem of wind plant inertial frequency response (IFR): shaping energy release and recovery to improve nadir while avoiding aerodynamic stall; representative simulations illustrate the issues without disclosing proprietary control. Section 4 develops MVDC concepts through an IEEE 16 bus loop and an Olympic Peninsula case study that compares AC vs. MVDC corridors and shows how feeder headroom can be pooled via DC couplers. Section 5 surveys SST architectures and identifies a gap: scalable, communication free coordination of multiple SSTs for islanded feeder networks. Across the report, novel methods and configurations under separate publication and IP review are not disclosed; only topic oriented, replicable setups and non proprietary results are shown. These models and use cases are intended as foundations for future publications and co design studies on architecture, control, and coordination of PE enabled grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗